Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Device Approval”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97Linked to original sources

Hysterosalpingography for assessing efficacy of Essure microinsert permanent birth control device.

OBJECTIVE: The Essure microinsert is a new U.S. Food and Drug Administration-approved method of birth control. The objective of this study is to report our initial experience using hysterosalpingography (HSG) to assess its efficacy for permanent tubal occlusion. CONCLUSION: The Essure microinsert produced tubal blockage in all patients. As this device may become more widely used, radiologists should be aware of the device's appearance and be able to assess device position and presence of tubal occlusion on HSG.

Adult↗

A comparative study of two devices used for cervical cell sampling raises some doubts about liquid-based cytology.

The objective of this study was to compare the quality of smears obtained by a newly designed cervical cell sampler (the implement) to those obtained with the cervex brush, using liquid-based cytology (LBC). A prospective randomized controlled trial with the approval of the local ethics committees after informing the Medical Devices Agency in the UK was used in this study. The study was carried out in colposcopy clinics in two district general NHS Trust Hospitals in London. A total of 200 women were recruited (100 from each hospital). The women were randomized into two groups, each of them having two smears at the same time. One hundred (50%) of the women had their first smear with the new implement, and the other 100 (50%) had their first smear with the cervex brush. The main outcome of this study is good-quality smears, assessed by evidence of effective sampling of the transformation zone, including immature metaplastic cells and also endocervical cells. Eighty-five percent of the smears taken by the new implement showed good-quality smears compared to 91% of those taken by the cervex brush, a statistically marginally nonsignificant result, with P value = 0.052 (McNemar exact test). A larger number of good-quality smears, judged by evidence of sampling of transformation zone, were obtained with the cervex brush, though the difference was statistically marginally nonsignificant, using the British society for clinical cytology criteria. Surprisingly, despite the use of LBC, there was a higher rate of inadequate smears obtained with both the devices (8% with each) compared to our previous study using the conventional slide test (1.3% with the new implement and 1.8% with the Jordan's spatula).

Cytodiagnosis↗

Health device legislation: an overview of the law and its impact on respiratory care.

The Medical Device Amendments of 1976 were intended to protect the public from unsafe and ineffective medical devices. The Food and Drug Administration (FDA) has general authority from this law to regulate medical devices but now must establish specific regulations to do so. In this process all devices are being classified in Class I (general controls), Class II (performance standards), or Class III (premarket approval). General controls impose relatively fewer restrictions, while premarket approval can require very strict laboratory and clinical testing. Classification panels have been grouping medical devices into these three classes. The Anesthesiology Device Classification Panel and the Pulmonary Function and Respiratory Therapy Subcommittee have recommended classifications for more than 200 types of devices. After comments from the public, the FDA will publish final device classifications, probably in 1979. The Medical Device Amendments also provide for release of safety and effectiveness data to the public, for tracing of devices in the field in case of recalls or problems, and for assistance to small manufacturers in complying with the law. The Medical Device Amendments should help to improve medical devices, but official regulations cannot accomplish everything. Users must also do their part by employing preventive maintenance and applying devices knowledgeably and safely.

Equipment and Supplies↗

Specimen adequacy and the ThinPrep Pap Test: the endocervical component.

The ThinPrep Pap Test (Cyryc Corp., Boxborough, MA) has proven to be effective in decreasing the number of cervical specimens limited for interpretation by blood/inflammatory exudate as compared to conventional smears. However, its effectiveness in decreasing the number of preparations which lack an endocervical component is less well-established. The purpose of this 1-yr study (January 1998-December 1998) was to determine if the collecting instruments used by physicians played a role in the lack of an endocervical component on ThinPrep slides. On implementation of the ThinPrep Pap Test for cervical cytology, the broom-type sampling device (Papette, Wallach Surgical Devices, Inc., Millford, CT) was the FDA-approved collecting instrument. Subsequently the combined plastic spatula/Zelsmyr Cytobrush (Medscand, Inc., Hollywood, FL) were approved. A survey was sent to 102 physicians in seven primarY care sites and two private obstetrics-gynecology practices affiliated with the Loyola University Health Care System. One site used the broom only, one site used the spatula/cytobrush, five sites used the broom/cytobrush, and in two sites, two different sets of collecting instruments were utilized. Of the 10,241 ThinPrep samples, 620 (6%) were obtained with the broom only, 432 (4.3%) with the spatula/cytobrush, and 9,189 (89.7%) with the broom/cytobrush. An endocervical component was absent in 24% (range, 13.7-25%) of the cervical samples collected with the broom only, 10% (range, 8.4-12.5%) with the spatula/cytobrush, and 13% (range, 6.2-18.8%) with the broom/ cytobrush. The spatula/cytobrush and the broom/cytobrush showed statistical significance (P < 0.001) over the broom alone in the collection of an endocervical component. The results of this study indicate that the collecting instruments used by the physician(s) played a role in the adequacy (endocervical component) of the specimen processed by the ThinPrep method. Diagn. Cyto

Adolescent↗

9.4T human MRI: preliminary results.

This work reports the preliminary results of the first human images at the new high-field benchmark of 9.4T. A 65-cm-diameter bore magnet was used together with an asymmetric 40-cm-diameter head gradient and shim set. A multichannel transmission line (transverse electromagnetic (TEM)) head coil was driven by a programmable parallel transceiver to control the relative phase and magnitude of each channel independently. These new RF field control methods facilitated compensation for RF artifacts attributed to destructive interference patterns, in order to achieve homogeneous 9.4T head images or localize anatomic targets. Prior to FDA investigational device exemptions (IDEs) and internal review board (IRB)-approved human studies, preliminary RF safety studies were performed on porcine models. These data are reported together with exit interview results from the first 44 human volunteers. Although several points for improvement are discussed, the preliminary results demonstrate the feasibility of safe and successful human imaging at 9.4T.

Burns, Electric↗

[Extracorporeal shockwave therapy in symptomatic heel spurs. An overview].

Extracorporeal shock wave application (ESWA) has been successfully used for years in routine clinical management of plantar fasciitis. So far no clinical trails have shown the efficiency in placebo-controlled protocols. This paper presents an overview of conservative and operative treatment modalities with respect to their efficacy. Results of a prospective randomized placebo-controlled double-blind multicenter trial to show efficiency and safety of ESWT are presented. In patients treated conservatively without success, a single shock wave application can improve the condition significantly compared with placebo treatment (p = 0.0149). The Roles and Maudsley score also showed a significant improvement between the groups, with 61.6% good or excellent results in the verum group and 39.7% in the placebo group (p = 0.0128). Therapy-related side effects (local swelling, petechia) are rare. The data presented in this study led to FDA approval in January 2002 of the shock wave device used.

Adult↗

Intravascular ultrasound imaging: a current perspective.

Catheter-based intravascular ultrasound imaging has evolved from a research tool to a device that has received Food and Drug Administration approval. Although it is currently employed as an adjunct to contrast angiography in both the peripheral and the coronary circulation, the indications for its use and its clinical utility have yet to be defined. Much of the research on the technique has explored its qualitative and quantitative capabilities to improve the assessment of atherosclerotic vascular disease. There is the hope that this imaging technique may ultimately improve the performance of endovascular interventions. This review describes the development of the technology from early in vitro validation studies to its present use in human subjects. Wherever possible, studies that validate the findings (that is, by comparison with histopathology results) of intravascular ultrasound are emphasized. Although there is great promise for this technology, limitations such as loss of image quality in severely diseased or heavily calcified vessels hinder its use. The application of imaging with endovascular intervention, imaging of intracardiac structures and the pulmonary circulation and new techniques such as computer image analysis are discussed.

Angiography↗

The effect of crystallinity on the deformation mechanism and bulk mechanical properties of PLLA.

Poly (l-lactide) is a widely studied biomaterial, currently approved for use in a range of medical devices, however, most in vitro studies have so far focussed upon either the bulk properties during degradation and/or deformation, or on the microstructure of the unloaded material during degradation. This study aimed to combine these approaches through the technique of simultaneous small-angle X-ray scattering and tensile testing at various stages of degradation up to 8 months, on material with a range of induced microstructures. Results showed that the amorphous material deformed by crazing in the dry, wet and degraded states, however, the mechanism by which the craze developed changed significantly on hydration. Despite this difference, there was little change in the bulk mechanical properties. Crystalline materials deformed through crystal-mediated deformation, with contributions from both cavitation and fibrillated shear, but surprisingly, differences in the length scales within the spherulitic structure caused by annealing at different temperatures had very little effect on the mechanism of deformation, though differences were seen in the bulk properties. Furthermore, hydration had little effect on the crystalline materials, though degradation over 8 months resulted in loss of mechanical properties for samples produced at higher annealing temperatures. In conclusion, the introduction of crystallinity had a huge effect on both bulk and microscopic properties of PLLA, but the spherulitic structure of the crystalline material affected the bulk properties significantly more than it did the micromechanism of deformation.

Absorbable Implants↗

Catheter-based recanalization techniques for acute ischemic stroke.

Recent advances in endovascular interventional therapies have revolutionized the management of acute ischemic stroke. For patients who present with occluded circle of Willis vessels, timely and successful arterial recanalization is the best predictor of clinical improvement. Diagnostic neuroimaging has advanced noninvasive tools--namely, transcranial Doppler, CT angiography, and MR angiography--to screen individuals with acute neurologic syndromes rapidly for arterial occlusion, and hence to exclude from treatment those who are unlikely to benefit from or could be harmed by arterial recanalization strategies. Intra-arterial thrombolysis has been proven to be of benefit in large clinical trials. Moreover, the US Food and Drug Administration has recently approved the use of a mechanical clot retrieval device for acute embolic stroke, and a number of other similar strategies are under various stages of investigation. This article reviews the diagnostic and interventional approach to the management of large vessel embolic stroke.

Acute Disease↗

[Reproductive activities as a risk factor of endometriosis].

A case-control study, involving 203 cases of pelvic endometriosis and 406 randomly selected and age-matched community controls, was conducted. The results were as following: 1) A decreased risk for endometriosis was found to be related to pregnancy. The relative risk was 0.34 for para 1 and 0.08 for para 2 or more. A similar tendency was also showed in the analysis of gravidity, but this protective effect totally disappeared after adjustment for parity. Therefore, it may be revealed that it is the parity but not the gravidity which protects the women against the endometriosis. 2) There was an increased risk of 15.35 for endometriosis in women with infertility. 3) No relation emerged with age at first pregnancy to the occurrence of endometriosis as indicated in the literature. 4) The frequency of induced abortion was 42.4% in the cases and that was 63.7% in the controls. The association with the risk of the disease adjusted for education, menstruation, parity and contraception was not significant by a attentive stratification the data. 5) Two groups were relatively similar with respect to recorded condom and oral contraceptive use. However, more cases than controls did not use any contraception or only used rhythm method and coitus interruptus, and more controls than cases used an intrauterine device. The results of multivariate analysis did not approve of opinion that IUD is a risk factor of endometriosis. The results did not negate the likelihood of diminished chance of developing endometriosis in women with using oral contraceptives.

Adult↗

The Food and Drug Administration and its influence on home bleaching.

The era of bleaching vital teeth has captured the attention of the dental profession, the public, the media, and the government. This method, using a custom-fitted mouthguard and a carbamide peroxide solution, is known as home bleaching, matrix bleaching, nightguard vital bleaching, passive bleaching, and dentist-prescribed-home-applied bleaching. Recent action of the US Food and Drug Administration and continued research and clinical experience in the area have provided favorable and unfavorable information about the variations of the technique. This article discusses these variations, with the general conclusion that the technique of vital tooth bleaching, when administered by a dentist using a custom-fitted mouthguard, is as safe as many other routinely performed dental procedures.

Carbamide Peroxide↗

[Self-administration of adrenaline aerosol in anaphylactic reactions after insect stings].

A serious allergic reaction after an insect sting is wellknown source for concern and anxiety. Patients with known hypersensitivity to insect stings are usually equipped with an adrenaline self-injection kit by an allergologist. In Denmark a new device for self-medication of adrenaline was approved in 1994, the adrenaline aerosol spray, Adrenalin Medihaler. The article is based on former studies and experiences, related to the usage of an adrenaline aerosol spray for the treatment of anaphylactic reactions after an insect sting. We conclude that adrenaline aerosol treatment should play an important role as emergency treatment for anaphylactic reactions after insect stings, and in most cases can replace the use of adrenalin self-injection kits. Adrenaline aerosol self-treatment could have an important beneficial effect helping to avoid exacerbation of the initial symptoms after insect venom exposition, such as bronchial obstruction and laryngeal oedema.

Aerosols↗

Managing clinical complexities of long-term contraception.

The 3 methods of long-term contraception (LTC) approved for use in the US are intrauterine devices (IUDs), levonorgestrel subdermal implants, and sustained-release medroxyprogesterone acetate injections. Women who use reversible LTC are likely to receive care from clinicians who did not prescribe the method of contraception originally. Fortunately, most concerns arising from the use of reversible LTC can be managed by clinicians regardless of their specialty. Problems associated with an IUD can include a missing string, partial expulsion of the device, change in menstrual pattern, vaginal discharge, or infection. Headaches, weight gain, dermatologic problems, changes in hair growth, and irregularities in menses are among the problems that clinicians may confront while caring for a woman who has had subdermal hormone implants or has been taking depot injections. Besides the problems caused by or complicating specific methods of LTC, a woman may seek clinical care for a variety of general concerns. These include a desire to terminate LTC in order to become pregnant, and physical changes that are suspected to indicate pregnancy or contraceptive failure. In addition, general health conditions such as concurrent medications, hypertension, and endocrine disorders may need special consideration in a woman using LTC. There are few medical indications for discontinuing or changing LTC, even when intercurrent illnesses arise.

Female↗

Infrainguinal arterial intervention: is there a role for an atherectomy device?

Excision of atheromatous plaque is an attractive option for the minimally invasive treatment of peripheral arterial disease. Approved for use in 2003, the SilverHawk Plaque Exicison System (FoxHollow Technologies, Redwood City, CA) is a catheter-based plaque excision device allowing percutaneous removal of atheromatous material. This device represents the most recent generation of atherectomy tools. Overall experience with plaque debulking in the peripheral arteries spans almost two decades, and understanding of the technique continues to evolve. This article reviews the technology, current practices, and data on plaque excision.

Atherectomy↗

Medical devices; classification/reclassification; restricted devices; analyte specific reagents--FDA. Final rule.

The Food and Drug Administration (FDA) is issuing a final rule to classify/reclassify analyte specific reagents (ASR's) presenting a low risk to public health into class I (general controls), and to exempt these class I devices from the premarket notification (510(k)) requirements. FDA is classifying/reclassifying ASR's used in certain blood banking tests as class II (special controls) because general controls are insufficient to provide a reasonable assurance of safety and effectiveness. Finally, ASR's presenting a high risk are being classified or retained in class III (premarket approval). FDA is also designating all ASR's as restricted devices under the Federal Food, Drug and Cosmetic Act (the act), and establishing restrictions on their sale, distribution and use. The scope of products covered by this final rule includes both pre- 1976 devices, which have not been previously classified, as well as post- 1976 devices, which are statutorily classified into class III. The intent of this final rule is to regulate these pre- and post-1976 devices in a consistent fashion. This rulemaking does not affect requirements for reagents that are subject to licensure under the Public Health Service Act (the PHS Act). This rulemaking also does not affect reagents sold to nonclinical settings, including those reagents sold as components to manufacturers of cleared or approved in vitro diagnostic tests.

Blood Banks↗

Permanent mechanical replacement of the left ventricle.

Patients with congestive heart failure have a poor prognosis and their care is expensive. Treatment with the HeartMate left ventricular assist device (Thermo Cardiosystems Inc, Woburn, MA) has indicated that life for such patients can be prolonged, quality of life increased, and cost of care decreased. Although currently approved only as a bridge to transplantation, the HeartMate and other such devices may one day offer permanent support of the left ventricle as an alternative to cardiac transplantation.

Cardiopulmonary Bypass↗

[Positron emission tomography--a technique for the routine practice of ambulatory care?].

Positron Emission Tomography (PET) has been regarded as a breakthrough technology that helps diagnoses various conditions. PET was developed in the United States during the 1960s, and has since diffused rather slowly into most modern health care systems. Germany is an exception, as here the diffusion of PET has been rapid, and more than 70 PET scanners have been installed. At present, PET scans are not included in the health care basket though they are often used and members of the statutory sickness fund frequently seek reimbursement for this technology. The Standing Committee therefore conducted a formal inquiry into the value of PET scanning in publicly funded (statutory) ambulatory health care. The Committee's decisions were based on a technology assessment of PET. This report found that PET has been approved by the German Federal Institute for Drugs and Medical Devices (BfArM) for five indications. The evidence for these five indications was compared to that for other diagnostic methods such as magnetic resonance imaging. The assessment found no convincing evidence to support the introduction of PET into statutory ambulatory health care in Germany. In April 2002 the Standing Committee consequently denied approval for the reimbursement of PET as a publicly funded diagnostic procedure.

Ambulatory Care↗