Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ChIP”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97Linked to original sources

Immobilization of the enzyme beta-lactamase on biotin-derivatized poly(L-lysine)-g-poly(ethylene glycol)-coated sensor chips: a study on oriented attachment and surface activity by enzyme kinetics and in situ optical sensing.

Understanding the conformation, orientation, and specific activity of proteins bound to surfaces is crucial for the development and optimization of highly specific and sensitive biosensors. In this study, the very efficient enzyme beta-lactamase is used as a model protein. The wild-type form was genetically engineered by site-directed mutagenesis to introduce single cysteine residues on the surface of the enzyme. The cysteine thiol group is subsequently biotinylated with a dithiothreitol (DTT)-cleavable biotinylation reagent. beta-Lactamase is then immobilized site-specifically via the biotin group on neutral avidin-covered surfaces with the aim to control the orientation of the enzyme molecule at the surface and study its effect on enzymatic activity using Nitrocefin as the substrate. The DTT-cleavable spacer allows the release of the specifically bound enzyme from the surface. Immobilization of the enzyme is performed on a monolayer of the polycationic, biotinylated polymer PLL-g-PEG/PEG-biotin assembled on niobium oxide (Nb2O5) surfaces via neutral avidin as the docking site. Two different assembly protocols, the sequential adsorption of avidin and biotinylated beta-lactamase and the immobilization of preformed complexes of beta-lactamase and avidin, are compared in terms of immobilization efficiency. In situ optical waveguide lightmode spectroscopy and colorimetric analysis of enzymatic activity were used to distinguish between specific and unspecific enzyme adsorption, to sense quantitatively the amount of immobilized enzyme, and to determine Michaelis-Menten kinetics. All tested enzyme variants turned out to be active upon immobilization at the polymeric surface. However, the efficiency of immobilized enzymes relative to the soluble enzymes was reduced about sevenfold, mainly because of impaired substrate (Nitrocefin) diffusion or restricted accessibility of the active site. No significant effect of different enzyme orientations could be detected, probably because the enzymes were attached to the surface through long, flexible PEG chain linkers.

Adsorption↗

Cholesterol modulated antibody binding in supported lipid membranes as determined by total internal reflectance microscopy on a microfabricated high-throughput glass chip.

A high-throughput microfabricated all-glass microchip, lipid biochip, was created and used to measure fluorescently tagged antibody binding to dinitrophenol (DNP) haptens in planar supported phospholipid/cholesterol lipid bilayers as a function of cholesterol-to-lipid molar ratio (X(CHOL)). Multiple parallel microchannels etched in the lipid biochip allowed simultaneous measurement of antibody binding to hapten-containing and hapten-free lipid bilayers, for a range of aqueous antibody concentrations. Specific and nonspecific antibody binding to the supported lipid bilayers was determined from the internally calibrated intensity of the surface fluorescence using total internal reflectance fluorescence (TIRF) microscopy. The TIRF intensity data of the specific antibody binding were fitted to the Langmuir isotherm and Hill equation models to determine the apparent dissociation constant K(d), the maximum fluorescence parameter F(infinity), and binding cooperativity n. As X(CHOL) increased from 0 to 0.50, K(d) exhibited a minimum of approximately 4 microM and n reached a maximum of approximately 2.2 at X(CHOL) approximately 0.20. However, F(infinity) appeared to be insensitive to the cholesterol content. The nonspecific binding fraction (NS), defined as the ratio of the TIRF intensity for hapten-free bilayers to that with hapten, showed a minimum of approximately 0.08 also at X(CHOL) approximately 0.20. The results suggest that cholesterol regulates the specific binding affinity and cooperativity, as well as suppresses nonspecific binding of aqueous antibody to a planar supported lipid bilayer surface at an optimal cholesterol content of X(CHOL) approximately 0.20. Interestingly, for X(CHOL) approximately 0.40, NS reached a maximum of approximately 0.57, suggesting significant packing defects in the lipid bilayer surface, possibly as a result of lipid domain formation as predicted by the lipid superlattice model. We conclude that cholesterol plays a significant role in regulating both specific and nonspecific antibody/antigen binding events on the lipid bilayer surface and that our lipid biochip represents a new and useful high-resolution microfluidic device for measuring lipid/protein surface binding activities in a parallel and high-throughput fashion.

Binding Sites, Antibody↗

Using bicellar mixtures to form supported and suspended lipid bilayers on silicon chips.

Bicellar mixtures, planar lipid bilayer assemblies comprising long- and short-chain phosphatidylcholine lipids in suspension, were used to form supported lipid bilayers on flat silicon substrate and on nanotextured silicon substrates containing arrays of parallel troughs (170 nm wide, 380 nm deep, and 300 nm apart). Confocal fluorescence and atomic force microscopies were used to characterize the resulting lipid bilayer. Formation of a continuous biphasic undulating lipid bilayer membrane, where the crests and troughs corresponded to supported and suspended lipid bilayer regions, is demonstrated. The use of interferometric lithography to fabricate nanotexured substrates provides an advantage over other nanotextured substrates such as nanoporous alumina by offering flexibility in designing different geometries for suspending lipid bilayers.

Lipid Bilayers↗

Ionic transport phenomena in nanofluidics: experimental and theoretical study of the exclusion-enrichment effect on a chip.

In nanometer-sized apertures with charged surfaces, the extension of the electrical double layer results in the electrostatic exclusion of co-ions and enrichment in counterions, which affects the permselectivity of such structures. A modeling of this phenomenon is proposed and is compared with quantitative measurements of the ionic permeability change of a Pyrex nanoslit at low ionic strength. The comparison of experimental results with theoretical predictions justifies that electrostatic forces are the governing forces in nanofluidics.

Journal Article↗

Enzymatic control of metal deposition as key step for a low-background electrical detection for DNA chips.

Electrical detection of DNA using nanoparticle labels in combination with metal enhancement represents an interesting alternative to fluorescence readout schemes. This electrical method is hampered by unspecific metal deposition, resulting in a lower sensitivity of the assay. A novel enhancement technique based on an enzymatic process is introduced. This approach enables highly specific metal deposition only at the enzyme label, without the background that is typical in the case of the conventional metal enhancement process of growing nanoparticles. The enzymatic enhancement leads to a significant increase in sensitivity, and the detection of single base mismatches demonstrates the high specificity of the novel enhancement approach.

Biosensing Techniques↗

pH-controlled diffusion of proteins with different pI values across a nanochannel on a chip.

Electrostatic interactions dominate the diffusion of proteins in a nanochannel, which was measured and modeled for pH values above and below the isoelectric points of three lectin proteins. Maximal diffusion coefficients were obtained when the proteins were neutral at their pI. This pH-controlled transport led to a separation of biomolecules across the nanochannel. A pI shift was observed, due to reversible adsorption of proteins on the walls, which affects the pH in the nanochannel.

Diffusion↗

Proteomic analysis using protein chips to detect biomarkers in cervical and amniotic fluid in women with intra-amniotic inflammation.

Intra-amniotic inflammation (IAI) may cause preterm birth with poor neonatal out-come. To identify novel biomarkers for IAI, we analyzed amniotic and cervical fluid samples from 27 patients with signs of threatening preterm birth with or without IAI by surface-enhanced laser desorption ionization time-of-flight mass spectrometry (SELDI-TOF-MS). Seventeen proteins were significantly overexpressed in amniotic fluid from IAI cases and more often in women with preterm labor than those with rupture of membranes. Five of these were identified as human neutrophil protein 1-3, calgranulin A and B.

Amniocentesis↗

MAP kinase pathways: molecular plug-and-play chips for the cell.

Mitogen-activated protein kinase (MAPK) pathways transduce a large variety of external signals in mammals, unicellular eukaryotes, and plants. In recent years, plant MAPK pathways have attracted increasing interest resulting in the isolation of a large number of different components. Studies on the function of these components have revealed that MAPKs play important roles in the response to a broad variety of stresses, but also in the signaling of plant hormones and the cell cycle. Besides giving an update on recent results, the success and logic of MAPK-based signal transduction cascades is discussed.

Gene Expression Regulation, Enzymologic↗

Apoptosis induced kinetic changes in autofluorescence of cultured HL60 cells-possible application for single cell analysis on chip.

INTRODUCTION: This paper presents a new method using natural cellular fluorescence (autofluorescence, AF) to study apoptosis. Measurement of AF reduces sample preparation time and avoids cellular toxicity due to the fact that no labelling is required. METHODS: Human promyelocytic leukemic HL60 cells were incubated with camptothecin (CPT), tumour necrosis factor (TNF)-alpha in combination with cycloheximide (CHX), or irradiated with 6 or 10 Gray, during varying time periods, to initiate apoptosis. AF was measured at the flow cytometer. RESULTS: Induction of apoptosis results in the shrinkage of the cell and the fragmentation into apoptotic bodies. With flow cytometry, 4 subpopulations, viable, early apoptotic, late apoptotic and the necrotic cells, can be distinguished. Induction of apoptosis results in a decrease in AF intensity compared to untreated HL60 cells, especially seen in the late apoptotic subpopulation. The AF intensity is found to decrease significantly in time (between 2 h and 24 h) for all the four apoptotic inducers used. CONCLUSIONS: Our results show that it is possible to specifically measure the apoptotic-induced kinetic changes in AF in HL60 cells. A decrease in AF intensity is seen from 2 h till 24 h. These results open a door for future developments in single-cell analysis.

Apoptosis↗

Cheaper chips?

Explore the source record for details and available documents.

Journal Article↗