Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ACRYLIC RESINS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97Linked to original sources

[Bond strength to dentin of resin composites associated with filled and unfilled adhesive systems].

This study analyzed in vitro two brands of one-step adhesive systems of fourth generation (Optisolo--Kerr, filled; and Single Bond--3M, unfilled) and two composite resins (Prodigy--Kerr and Z100--3M), aiming at evaluating their bond strength to dentin. Eighty human extracted molars were embedded in acrylic resin and grounded until dentin was exposed in longitudinal direction. The specimens were divided in 4 groups. Composite resin cones were bonded to the specimens using the mentioned adhesive systems, following the instructions of the manufacturers. The test-specimens were submitted to tensile tests using a 4442 Universal Mini-Instron Machine with the speed of 0.5 mm/min. The results were converted into MPa, according to the area of adhesion, and submitted to statistical analysis with ANOVA. There was significant statistical difference (p < 0.01) between the adhesive systems (F = 7.24). Optisolo (m = 11.03 +/- 4.23) showed better bond strength than Single Bond (m = 8.37 +/- 4.54). There was no significant statistical difference (p > 0.05) between the composites (F = 0.43).

Bisphenol A-Glycidyl Methacrylate↗

A hydrophilic resin-embedding method for light and electron microscopic detection of tissue anionic sites with cationic colloidal iron: as applied to mouse Paneth cells.

A cationic colloidal iron method was introduced for electron microscopic detection of anionic sites in hydrophilic resin-embedded specimens, and the method was applied to Paneth cells of the mouse jejunum. Mouse jejunal blocks were embedded in hydrophilic acrylic resin (LR White), cut into ultrathin sections, stained with the diluted cationic colloidal iron, and exposed to osmium vapor. The jejunal tissues, including the Paneth cells, embedded in hydrophilic resin were reactive to the fine cationic colloidal iron. At pH value 1.5, fine electron dense colloidal iron deposited along the rims of the secretory granules and the Golgi apparatus of the Paneth cell. Colloidal particles distributed on the osmiophilic reticular structures in the rim and in dot-like fashion lined the border between the granular core and rim. At pH value 4.0, ribosomes reacted to cationic colloidal iron particles in addition to the granular rims and Golgi apparatus. At pH 7.0, even the cores of the secretory granules were stained. Semi-thin sections prepared from the LR White-embedded specimens and stained at pH 1.5 with the diluted (1:3 in volume) cationic colloidal iron showed sufficient Prussian blue reaction for light microscopy in the rims of Paneth granules and mucus of goblet cells. This method is therefore useful for correlative light and electron microscopic detection of tissue anionic sites, including sulfate, carboxyl and phosphate groups, at various pH values.

Animals↗

Scanning electron microscopy evaluation of the interface of three adhesive systems.

The objective of this research was to investigate the resin-dentin interface of three adhesive systems, Scotchbond Multi-Purpose, Optibond and Denthesive Bond II by scanning electron microscopy. The adhesives and their respective composite resins were applied inside the cervical root canal of human incisors and canines according to manufacturer recommendations. The teeth were embedded in acrylic resin and sliced transversally to the root canal and perpendicularly to the resin-dentin interface. The adhesive systems Scotchbond Multi-Purpose and Optibond had a homogenous hybrid layer and similar characteristics, involving resin penetration of peritubular and intertubular dentin matrix. Morphological differences of resin tags were seen; Scotchbond Multi-Purpose had more and longer tags than Optibond. Denthesive Bond II did not have the same consistency of bonding. Tubular orifices were not opened and the smear layer was not removed. This was due to the absence of previous acid conditioning of dentin that damages hybrid layer formation. Analysis of the hybrid layer revealed different patterns, suggesting that the attachment was influenced by many factors and a standardization of dentinal substrate was impossible.

Adhesives↗

Enzyme histochemical demonstration of NADH dehydrogenase on resin-embedded tissue.

We describe a method for enzyme histochemical demonstration of NADH dehydrogenase in cold (4 degrees C)-processed resin-embedded tissue. The effects on NADH dehydrogenase activity of processing tissue through a variety of dehydrating agents and embedding in three different acrylic resins were evaluated. The optimal procedure to maintain NADH dehydrogenase activity used a short (3-hr) fixation in 1% paraformaldehyde solution, followed by dehydration in acetone and embedding in glycol methacrylate resin. Embedding of tissue in resin combined preservation and accurate localization of NADH dehydrogenase activity with good tissue morphology. Blocks of the resin-embedded tissue could be stored at room temperature for at least 6 months without loss of NADH dehydrogenase activity.

Animals↗

Effects of handpiece lubrication on resin-based composite bond strength to enamel.

PURPOSE: To evaluate the effects of handpiece lubrication on the bond strengths of resin-based composite (RBC) to enamel using two different bonding systems. MATERIALS AND METHODS: Sixty extracted noncarious human maxillary incisors were imbedded in acrylic resin tray material with the facial surfaces exposed. 320 grit sandpaper was used to create a flat surface of enamel. The embedded teeth were randomly divided into two bonding systems groups: half used All-Bond 2 and half used OpiBond FL. Within these two groups the teeth were again randomly divided into three subgroups: Dry: 10 teeth prepared with a sterilized unlubricated handpiece; Lube & Run: 10 teeth prepared with a handpiece that was lubricated and run for 30 seconds prior to use; Lube: 10 teeth prepared with a handpiece that was lubricated and not run prior to its use. The enamel was prepared by lightly roughening with a medium grit diamond in the respective handpieces. The preparations were etched for 15 s with 32% phosphoric acid, rinsed with water for 5 s, and dried with compressed air for 5 s. Either bond system was applied and light-cured. A hybrid RBC was placed and light-cured for 60 s. The teeth were stored in water at 37 degrees C 1 week. Shear bond strengths were measured and the collected data subjected to an ANOVA followed by a Tukey's and Bonferroni t-test were performed. RESULTS: The Dry group and the Lube & Run group had stronger mean shear strengths than did the Lube group. The difference between the mean shear strengths for the Dry group and the Lube & Run group was not statistically significant (P < 0.05). A significant difference was found between the Dry group and the Lube group and between the Lube & Run group and the Lube group (P < 0.05). The mean shear strength for All-Bond 2 was higher than for OptiBond FL (P = 0.0054).

Analysis of Variance↗

Resistance to fracture of endodontically treated teeth restored with different post systems.

STATEMENT OF PROBLEM: Very little is known about the resistance to fracture of endodontically treated teeth restored with newly developed esthetic post systems. Purpose. This in vitro study compared the effect of 1 titanium and 3 esthetic post systems on the fracture resistance and fracture patterns of crowned, endodontically treated teeth. MATERIAL AND METHODS: A total of 40 recently extracted human maxillary canines with their crowns removed were endodontically treated. Four groups of 10 specimens were formed. Teeth were restored with titanium, quartz fiber, glass fiber, and zirconia posts and numbered as groups 1, 2, 3, and 4, respectively. All posts were cemented with Single Bond dental adhesive system and dual-polymerizing RelyX ARC adhesive resin cement. All teeth were restored with composite cores, and metal crowns were fabricated and cemented with glass ionomer cement. Each specimen was embedded in acrylic resin and then secured in a universal load-testing machine. A compressive load was applied at a 130-degree angle to the long axis of the tooth until fracture, at a crosshead speed of 1 mm/min. One-way analysis of variance and a Tukey test were used to determine the significance of the failure loads between groups (P<.001). A non-parametric chi(2) test was conducted for evaluation of the mode of failure (P<.001). RESULTS: The mean failure loads (kg) were 66.95, 91.20, 75.90, and 78.91 for groups 1 to 4, respectively. Teeth restored with quartz fiber posts (group 2) exhibited significantly higher resistance to fracture (P<.001) than the other 3 groups. Teeth restored with glass fiber and zirconia posts (groups 3 and 4) were statistically similar (P>.05). Fractures that would allow repair of the tooth were observed in groups 2 and 3, whereas unrestorable, catastrophic fractures were observed in groups 1 and 4 (P<.001). CONCLUSION: Within the limitations of this study, significantly higher failure loads were recorded for root canal treated teeth restored with quartz fiber posts. Fractures that would allow repeated repair were observed in teeth restored with quartz fiber and glass fiber posts.

Analysis of Variance↗

Fracture resistance of endodontically treated teeth restored with three different prefabricated esthetic posts.

PURPOSE: This study was undertaken to evaluate the role of composition of prefabricated esthetic posts in fracture resistance of endodontically treated teeth in vitro. MATERIALS AND METHODS: Thirty human, single-rooted teeth (maxillary central incisors and canines) with similar root dimensions, extracted for therapeutic reasons, were used in this study. The crowns were removed below the cementoenamel junction to obtain a standard root length of 17 mm. The roots were endodontically treated following the conventional manual technique and randomly assigned to three groups (n = 10) according to the post used: Aestheti-Post, Bisco, Schaumberg, Illinois; FibreKor Post, Jeneric/Pentron, Wallingford, Connecticut; and CosmoPost, Ivoclar Vivadent, Schaan, Liechtenstein. The root canals were rendered patent, and the root preparations were standardized through flaring with the manufacturers' drills included in the respective kits. The posts were cemented with an adhesive system and a resin cement (All-Bond 2 and C&B, Bisco, respectively), according to the manufacturers' directions. Composite resin (Tetric Ceram, Ivoclar Vivadent) crowns were built up using a preformed polyester matrix, and the specimens were mounted in metallic rings with cold-cure acrylic resin and kept in saline solution at 4 degrees C for 24 hours. Fracture resistance was then determined using an EMIC DL-2000 universal testing machine. The crosshead speed was 0.5 mm/min with the 45-degree compressing load at the middle third of the crown. Data were analyzed using one-way analysis of variance and Tukey's test (p < or = .001). RESULTS: Mean fracture resistance was as follows: Aestheti-Post, 83.5 kgf; FibreKor Post, 85.7 kgf; and CosmoPost, 36.5 kgf. The fracture strength of CosmoPost was significantly lower than that of the other posts. Teeth restored with CosmoPost had post fractures, and in three specimens, those were associated with root fractures. Teeth restored with the other two posts presented fractures on the composite crowns.

Analysis of Variance↗

[Composite resin copings for a perio-overdenture. A newly developed method of making copings for retention with spherical elements].

Today's dentistry should aim at minimizing cost, simplifying techniques, allowing procedural revi sions and finally at facilitating corrections and repairs. The development of direct or indirect light-cured composite resin copings, coupled with ball attachments (Dalbo-Rotex according to Brunner) and a suprastructure which is veneered by means of light-cured composite or acrylic resin, may offer a cost-effective perio-overdenture without compromising on periodontal health and providing optimal esthetics. Since July 2003, eighteen new perio-overdentures with a total of 70 copings made of light-cured microhybrid composite resin were delivered. The aim of this article is to discuss the technical aspects and preliminary results regarding this technique.

Aged↗

Synthesis of peptide sequences related to thrombospondin: factors affecting aspartimide by-product formation.

Aspartimide formation is one of the most common secondary reactions on solid phase peptide synthesis. In the present work, we describe the optimization of the synthesis of two thrombospondin fragments containing an Asp-Gly sequence that show a strong tendency to form cyclic aspartimide derivatives in an unusual high percentage. Several different strategies were applied changing type of resin, Fmoc-deprotection reagents, coupling additives, resin cleavage cocktails and the use of Hmb-Gly derivative to minimize the extension of this byproduct. Best results were obtained with cross-linked ethoxylate acrylate (CLEAR-cross-linked ethoxylate Acrylate Resin)-type resin and pip/dimethylformamide deprotection. Besides, as in biological assays the aspartimide containing sequence resulted to be more active than the linear one, the optimization of its synthesis was also carried out.

Amino Acid Sequence↗

Force transmission of one- and two-piece morse-taper oral implants: a nonlinear finite element analysis.

PURPOSE: To compare force transmission behaviors of one-piece (1-P) and two-piece (2-P) morse-taper oral implants. MATERIAL AND METHODS: A three-dimensional finite element model of a morse-taper oral implant and a solid abutment was constructed separately. The implant-abutment complex was embedded in a phi 1.5 cm x 1.5 cm acrylic resin cylinder. Vertical and oblique forces of 50 N and 100 N were applied on the abutment and solved by two different analyses. First, contact analysis was performed in the implant-abutment complex to evaluate a 2-P implant. Then, the components were bonded with a separation force of 10(20) N to analyze a 1-P implant. RESULTS: Von Mises stresses in the implant, principal stresses, and displacements in the resin were the same for both designs under vertical loading. Under oblique loading, principal stresses and displacement values in the resin were the same, but the magnitudes of Von Mises stresses were higher in the 2-P implant. The principal stress distributions around both implants in the acrylic bone were similar under both loading conditions. CONCLUSION: 2-P implants experience higher mechanical stress under oblique loading. Nevertheless, the 1-P- or 2-P morse-taper nature of an implant is not a decisive factor for the magnitude and distribution of stresses, and displacements in supporting tissues.

Compressive Strength↗

Direct post and core pattern made with light-curing composite resin.

An unfilled Bis-GMA composite resin can be used advantageously for making an accurate cast post and core pattern. The technique is faster and easier than normal pattern fabrication methods using an unfilled acrylic resin, wax, or a combination of the two.

Bisphenol A-Glycidyl Methacrylate↗

An in vivo and in vitro comparison of two dentin bonding agents.

The in vitro and in vivo shear bond strengths of two dentin bonding agents to dentin were measured by use of a goat model. The dentin was exposed in the mandibular incisors of 10 adult goats while they were maintained under general anesthesia. Separate gingival and incisal areas of dentin were isolated with Teflon tape, exposing an area 2.83 mm in diameter. GLUMA or Scotchbond II was applied to those dentin areas according to the manufacturers' directions. A column of resin was then applied over the bonding agent and light-cured. Two hours later, the animals were killed and the teeth removed. The teeth were then mounted in acrylic resin, and the resin composite tube was loaded in shear until failure on an Instron. Seven days later, the extracted teeth were re-prepared and the same bonding procedure re-applied. These teeth were placed in the Instron and loaded in shear until failure. Thirteen months later, the teeth bonded with GLUMA were re-prepared and bonded in the same manner as above. The resin composite was loaded in shear until failure. There was no significant difference between the two-hour in vivo bond strength and the seven-day or the 13-month in vitro bond strength with GLUMA. There was no significant difference between the two-hour in vivo or the seven-day in vitro bond strength for Scotchbond II. There was no significant difference between the shear bond strengths of the two dentin bonding agents.

Analysis of Variance↗

Effect of the dentin cleansing techniques on dentin wetting and on the bond strength of a resin luting agent.

STATEMENT OF PROBLEM: Remnants of the provisional cement on prepared teeth may have an adverse effect on the performance of the definitive luting agent. PURPOSE: This in vitro study investigated the effect of different dentin cleansing techniques on the bond strength of a resin luting agent and dentin wetting. MATERIAL AND METHODS: Sixty buccal or lingual coronal portions of human molar teeth were mounted, with the buccal or lingual surfaces up, in acrylic resin blocks. The specimens were prepared until the dentin was exposed and a eugenol-containing provisional cement (Temp Bond) was applied to the dentin surfaces. After mechanical removal of the cement with a carving instrument, specimens were divided into 6 groups of 10 specimens each. The dentin surfaces of the specimens were treated with 1 of 5 cleansing techniques: Group S, cleansing agent (Sikko Tim); Group C, cleansing agent (Cavity Cleanser); Group O, rotary instrumentation (OptiClean); Group OS, rotary instrument preceding Sikko Tim; and Group OC, rotary instrumentation preceding Cavity Cleanser. The remaning 10 specimens were untreated and served as controls (CT). An adhesive resin luting agent (Variolink II) was applied to all specimens. Shear bond strength (MPa) was measured using a universal testing machine at a 0.5 mm/min crosshead speed. To measure the contact angle, another 6 groups (n=5) were prepared using the same methods. Contact angle measurements were performed to assess wettability using the Axisymmetric Drop Shape Analysis-Contact Diameter (ADSA-CD) technique. Wettability measurements were made with water. Data were statistically analyzed by 1-way analysis of variance with Tukey HSD tests (alpha=.05). The effect of the dentin cleansing techniques on removing the provisional cement from the dentin surface was examined with scanning electron microscope (SEM). RESULTS: Specimens cleaned with all techniques showed stronger shear bond strength values than control specimens (P<.001), with the exception of C specimens. The surface cleansing techniques tested affected the dentin wetting significantly in comparison with the control group (P<.001), except for the C and the O groups. There was no significant difference in wetting between the groups C and O. The SEM observations demonstrated that the dentin cleansing techniques left differing amounts of provisional cement remnants. CONCLUSION: Specimens treated with only the cleansing agent Sikko Tim showed the highest bond strength, likely due to the solvent effect of Sikko Tim on the removal of provisional cement. The lowest bond strength was obtained with the rotary instrument. It was concluded that the provisional cement could plug the dentinal tubules into which the resin luting agent penetrates.

Dental Bonding↗

Shear bond strengths of tooth fragments reattached or restored.

This study investigated the shear bond strengths of sectioned human mandibular incisor edge fragments reattached using luting cements, bonding agents or restored with composite resins. Seventy teeth were randomly distributed among six experimental groups and a control group. Leaving half of the anatomic crowns exposed, the teeth were embedded in self-cure acrylic resins with the exposed part then sectioned. The fragments in groups 1-4 were bonded to their respective teeth using Clearfil Liner Bond 2V, Scotch Bond Multi Purpose Plus, Panavia-F and 3M Opal Luting cement. The 5th and 6th groups were restored with composite resins (Silux 3M and Clearfil AP-X) using their bonding agents (Single Bond and Clearfil SE Bond). The results indicated that reattachment of fractured incisal fragments by using new generation bonding agents was effective against shear stresses, comparable with the intact teeth. Instead of restoration with composite resins therefore reattachment of a fractured fragment might be more preferable in cases of dental trauma.

Composite Resins↗

An easy method for orientated embedding tissue culture cell monolayers in LR White resin for postembedding immunocytochemistry.

Partial polymerization of LR White resin blocks is a frequently encountered problem if oxygen is present during the polymerization reaction. Instructions are given for a simple method to embed cell culture monolayer in LR White acrylic resin, which is suitable for immunocytochemistry. The advantage of this method is that it is easy and reliable. It also ensures accurate orientation of the cell monolayer in relation to the desired plane of sectioning.

Animals↗

In situ microhardness evaluation of glass--ionomer/composite resin hybrid materials at different post-irradiation times.

The purpose of this paper was to evaluate in situ the microhardness of a composite resin, two resin-modified glass-ionomers and two polyacid-modified composite resins at different post-irradiation times. The materials analysed were: Z 100/3M (Z1); Fuji II LC/GC Corporation (Fu); Vitremer/3M (Vi); Freedom/SDI (Fr); and Dyract/Dentsply (Dy). Palatal intra-oral acrylic resin appliances were made for each of the 24 volunteers in the experiment. In each appliance, a specimen of each material was fixed. Microhardness tests were performed at 30 min, 1, 2, 4, 8, 24 and 48 h, 7, 10, 14, 17 and 21 days after initial light-curing. The analysis of variance followed by the Tukey test showed significant differences of microhardness among all materials (Fu < Vi < Fr < Dy < Z1) up to 48 h. From the seventh to the fourteenth day, statistical differences were not found between Freedom and Dyract (Fu < Vi < Fr=Dy < Z1). On the seventeenth and twenty-first days, Vitremer, Freedom and Dyract did not present statistical differences, but differed from Fuji II LC and Z 100 (Fu < Vi=Fr=Dy < Z1). The polynomial regression showed an increase of microhardness over time for the glass-ionomers/composite resin hybrid materials, although there were differences of microhardness among these materials. There was no significant changes in microhardness levels for the composite resin over time.

Adult↗

Shear bond strength of one-bottle dentine bonding systems.

The purpose of this in vitro study was to determine the shear bond strength (SBS) of composite resin to human, buccal dentine, using four one-bottle dentine bonding systems. Eighty recently extracted human molar teeth were embedded in metal rings by means of self-curing acrylic resin. The projecting buccal surfaces were ground wet on 600 grit silicone carbide paper in order to expose superficial dentine. The teeth were randomly divided into four groups (N=20): 1=Prime&tBond 2.1 (PB, Dentsply); 2=Scotchbond 1 (SB, 3M); 3=Optibond Solo (OS, Kerr) and 4=Syntac Single Component (SY, Vivadent). The dentine surfaces were etched, treated with one of the four dentine bonding systems, and cylinders of matching composites were then bonded to the surfaces by means of a silicone rubber split mould. All specimens were stored for 24 hours under water at 37 degrees C. The bonds were then stressed to failure with an Instron testing machine, operating at a crosshead speed of 0.5 mm/min. The data were statistically analysed (Kruskall-Wallis). The mean SBS (MPa) were: PB = 12.5 +/- 2.0; SB = 16.2 +/- 1.9; OS = 17.4 +/- 3.1 and SY= 8.1 +/- 1.9. There was a statistically significant difference (P = 0.0001) between the mean of SY and the other 3 groups, and also between PB and the other groups. There was no statistically significant difference (P = 0.244) between the SBS of OS and SB. SY demonstrated the lowest SBS.

Bisphenol A-Glycidyl Methacrylate↗