Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Pulsatile Flow”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96Linked to original sources

The hydrodynamic function and leaflet dynamics of aortic and pulmonary roots and valves: an in vitro study.

Fresh homograft aortic and pulmonary roots were tested in a pulsatile flow simulator to assess their hydrodynamic function and leaflet opening characteristics. Simultaneous flow and pressure measurements were obtained for a range of cardiac outputs. The effective orifice area and regurgitant volumes were calculated. The mean pressure difference across the pulmonary roots was obtained under both left and right side pressures. A video recording of valve leaflet function was also obtained for each valve. A comparison was made with four porcine bioprosthetic heart valves (21 and 23 mm). The mean pressure difference with respect to flow for the 21 mm Hancock II and Intact porcine bioprostheses was significantly higher than that for all aortic roots tested. The 24 mm aortic root showed significantly lower pressure drop compared to all porcine valves tested. The mean pressure difference across each pulmonary root at pulmonary pressures was significantly greater than at systemic pressures. At systemic pressures the fully open leaflets had a triangular orifice with low leaflet open bending strains at the commissures. At the lower internal pressures, with reduced dilation of the root, higher bending strains were noted. These were not as severe as seen in porcine valves.

Adult↗

Regurgitant jet evaluation using three-dimensional echocardiography and magnetic resonance.

BACKGROUND: Three-dimensional assessment of regurgitant jet volume is the prerequisite for stratifying valve insufficiency. However, systematic comparison of three-dimensional methods is lacking. Therefore, we evaluated magnetic resonance imaging and three-dimensional echocardiography experimentally. METHODS: An insufficiency chamber (22 x 18.5 x 27 cm; ostia 10, 16, and 20 mm; regurgitant volumes 2.3 to 25 mL) within experimental circulation (BioMedicus pump, tubes, pulsatile flow 0.2 to 1.9 L/min) was used for three-dimensional echocardiography (HP Sonos 2500) and magnetic resonance imaging (Siemens Magnetom Vision). Doppler flowmeter served as a gold standard. Segmentation used thresholding and surface integration of velocity vectors. Jet volume was evaluated qualitatively by polynom fitting. RESULTS: Jet volume calculated by magnetic resonance (r = 0.99, p < 0.0001) and by echocardiography (r = 0.99, p < 0.0001) correlated identically to the gold standard. Jet volume derived from imaging correlated with each other by r = 0.98 (p < 0.0001). Polynom fits indicated a more paraboloid shape of magnetic resonance jet volume. CONCLUSIONS: Experimentally, three-dimensional echocardiography and magnetic resonance imaging possess identical accuracy for determining regurgitant jet volume. Magnetic resonance imaging seems to provide qualitatively better image data for three-dimensional reconstruction.

Echocardiography, Three-Dimensional↗

Aortic dissection with potential origin from a mechanical bypass anastomosis.

Ascending aortic dissection is a known complication of cardiac surgery. Off-pump coronary artery bypass surgery seems to be associated with a higher risk for this event as compared with on-pump bypass surgery. This increased risk may result from aortic side-clamping under pulsatile flow as opposed to continuous flow in conventional bypass surgery. Mechanical devices allowing performance of proximal bypass anastomoses without aortic side-clamping are supposed to reduce the risk for aortic dissection. We report a case in which ascending aortic dissection occurred 8 days after off-pump bypass surgery, most likely arising from a mechanically performed proximal bypass anastomosis.

Aged↗

Physical characterization of vascular grafts cultured in a bioreactor.

Tubular scaffolds of collagen and elastin (weight ratio 1:1) with interconnected pores were prepared by freeze drying and crosslinked with N-(3-dimethylaminopropyl)-N'-ethylcarbodiimide hydrochloride (EDC) and N-hydroxysuccinimide (NHS) in the presence or absence of a Jeffamine spacer (poly(propylene glycol)-bis-(2-aminopropyl ether), J230). The crosslinked and uncrosslinked matrices had porosities of 90% and average pore sizes of 131-151 microm. Smooth muscle cells (SMC) were cultured in the crosslinked and uncrosslinked tubular scaffolds under pulsatile flow conditions (mean flow rate 9.6 ml/min, 120 beats/min, pressure 80-120 mmHg). All the constructs could withstand cyclic mechanical strain in the absence of any mechanical support without cracking or suffering permanent deformation. After 7d, SMC were homogeneously distributed throughout the uncrosslinked and EDC/NHS crosslinked constructs, whereas hardly any cell was observed on the luminal side of J230/EDC/NHS crosslinked matrices. Considering the better mechanical performance of EDC/NHS crosslinked matrices compared to non-crosslinked constructs after 7d of culture, SMC were dynamically cultured in the former scaffolds for 14d. During this period, the high strain stiffness of the constructs increased more than two-fold to 38+/-2 kPa, whereas the low strain stiffness doubled to 8+/-2 kPa. The yield stress and yield strain were 30+/-10 kPa and 120+/-20%, respectively. SMC were homogeneously distributed throughout the EDC/NHS crosslinked collagen/elastin constructs and collagen fibres tended to orient in the circumferential direction.

Biocompatible Materials↗

Changes of opening angle in hypertensive and hypotensive arteries in 3-day organ culture.

To study the effect of pressure changes on the opening angle of arteries in organ culture, tubular segments of porcine common carotid arteries were cultured with pulsatile flow perfusion under hypertensive (150+/-20 mmHg), normotensive (100+/-20 mmHg), or hypotensive (30+/-10 mmHg) pressure while maintaining the arteris at a physiological wall shear stress of approximately 15 dyn/cm(2) for up to 3 days. Arteries were then cut into short ring segments by sections perpendicular to the axis and then cut open radially to observe the opening angle in aerated phosphate buffered saline solution (37 degrees C). Norepinephrine (NE, 10 microM), carbacol (CCh, 100 microM), and sodium nitroprusside (SNP, 10 microM) were added after the radial cut at 30, 20, and 30 min intervals, the opening angles were measured, respectively. Results show that hypertensive arteries developed a significantly larger opening angle than normotensive and hypotensive arteries, associated with a significant increase in cell proliferation. In addition, with smooth muscle contraction activated by NE, the opening angle decreases significantly in hypertensive arteries but has little change in hypotensive and normotensive arteries, indicating an enhancement of smooth muscle contraction on the lumen side of the hypertensive arterial wall. In comparison, hypotensive pressure has little effect on arterial opening angle and cell proliferation.

Animals↗

Development of an artificial vessel lined with human vascular cells.

OBJECTIVES: Thrombogenity of small-diameter vascular prostheses might be reduced by complete coverage of the luminal surface with vascular cells. We investigated cell seeding on polyurethane vascular prostheses. METHODS: Thirty polyurethane vascular prostheses were divided into 3 groups of 10 each: group A, diameter of 20 mm and gamma-sterilized; group B, diameter of 4 mm and gamma-sterilized; and group C, diameter of 4 mm and ethylene oxide sterilized. Human smooth muscle cells, fibroblasts, and endothelial cells were isolated from saphenous vein segments and expanded in culture. Five polyurethane vascular prostheses of each group were seeded with endothelial cells alone (mean, 4.8 +/- 1.2 x 10(6) cells), and the remaining 5 polyurethane vascular prostheses were preseeded with a mixed culture of fibroblasts and smooth muscle cells (mean, 7.7 +/- 2.3 x 10(6) cells), followed by endothelial cell seeding (mean, 4.4 +/- 0.9 x 10(6) cells). Seven days after cell seeding, the polyurethane vascular prostheses were perfused under a pulsatile flow (80 pulses/min, 140/80 mm Hg, and 120 mL/min) for 2 hours. Specimens were taken after each seeding procedure both before and after perfusion and then examined both with a scanning electron microscope and immunohistochemically. RESULTS: Isolated endothelial cell seeding revealed better initial adhesion in groups A and B than in group C (63% vs 33%). After 7 days, the cells had covered approximately 80% of the luminal surface in groups A and B, whereas group C cells rounded up and lost adhesion. After perfusion testing of group A and B prostheses, only 10% of the surface was still covered with endothelial cells. Preseeding with the mixed culture again revealed a better initial adhesion in groups A and B compared with that in group C (76% vs 41%). In groups A and B endothelial cell seeding (adhesion, 72%) resulted in a confluent endothelial cell layer. The results of immunohistochemical staining were positive for collagen IV, laminin, CD31, and Factor VIII. In group C only isolated cells were found after each seeding procedure, which rounded up and vanished during the next days. Perfusion testing of group A and B prostheses revealed that the confluent cell layer remained stable, with only small defects (<10% of the surface). The cells stained positivively for endothelial nitric oxide synthase. CONCLUSION: Seeding of a mixed culture out of fibroblasts and smooth muscle cells resulted in improved endothelial cell adhesion and resistance to shear stress. This outcome was caused by an increased synthesis of extracellular matrix proteins. Cell attachment was better on gamma-sterilized polyurethane vascular prostheses compared with on those undergoing ethylene oxide sterilization.

Bioartificial Organs↗

In vitro hydrodynamics, cusp-bending deformation, and root distensibility for different types of aortic valve-sparing operations: remodeling, sinus prosthesis, and reimplantation.

OBJECTIVE: Preserving aortic valve cusps during operations for aortic root pathology theoretically offers several advantages over alternative prosthetic valve-bearing conduits. Functional properties of different valve-sparing techniques under defined conditions are not well studied. METHODS: Fresh porcine aortic roots were investigated in a pulsatile flow simulator, either native root or after different types of valve-sparing procedures (remodeling, sinus prosthesis, and reimplantation). Functional parameters, such as transvalvular pressure gradient, closing volume, cusp-bending deformation, and distensibility at different levels of the root were analyzed. RESULTS: The mean pressure gradient was highest in reimplantation techniques (8.4 +/- 1.8 mm Hg) compared with sinus prostheses (7.2 +/- 0.9 mm Hg, P = .01) and remodeling techniques (6.8 +/- 1.0 mm Hg, P = .002), mirror imaging the closing volume (reimplantation, 1.5 +/- 0.4 mL; sinus prostheses, 2.3 +/- 0.7 mL [P < .001]; remodeling, 3.4 +/- 1.1 mL [P < .001]). Bending deformation indices increased significantly from remodeling (0.45 +/- 0.05) and sinus prostheses (0.58 +/- 0.06) to reimplantation techniques (0.73 +/- 0.09). Dynamic changes in area of all techniques were decreased at the sinotubular junction and the commissural and sinus levels when compared with those seen in native roots but increased at the annular level for techniques with unfixed annulus (remodeling and modified sinus prosthesis). CONCLUSIONS: In vitro the various aortic valve-sparing operations differed characteristically in their ability to spare valve function, none of them completely meeting native valve behavior. The remodeling techniques exhibited valve dynamics closest to those of the native aortic root. The more the aortic valve is fixed with noncompliant prosthetic material, the more the native root dynamics are impaired.

Animals↗

Artificial blood vessel: the Holy Grail of peripheral vascular surgery.

Artificial blood vessels composed of viable tissue represent the ideal vascular graft. Compliance, lack of thrombogenicity, and resistance to infections as well as the ability to heal, remodel, contract, and secrete normal blood vessel products are theoretical advantages of such grafts. Three basic elements are generally required for the construction of an artificial vessel: a structural scaffold, made either of collagen or a biodegradable polymer; vascular cells, and a nurturing environment. Mechanical properties of the artificial vessels are enhanced by bioreactors that mimic the in vivo environment of the vascular cells by producing pulsatile flow. Alternative approaches include the production of fibrocollagenous tubes within the recipient's own body (subcutaneous tissue or peritoneal cavity) and the construction of an artificial vessel from acellular native tissues, such as decellularized small intestine submucosa, ureter, and allogeneic or xenogeneic arteries. This review details the most recent developments on vascular tissue engineering, summarizes the results of initial experiments on animals and humans, and outlines the current status and the challenges for the future.

Animals↗

Human factors as a source of error in peak Doppler velocity measurement.

OBJECTIVE: The study was conducted to assess the error and variability that results from human factors in Doppler peak velocity measurement. The positioning of the Doppler sample volume in the vessel, adjustment of the Doppler gain and angle, and choice of waveform display size were investigated. We hypothesized that even experienced vascular technologists in a laboratory accredited by the Intersocietal Commission for Accreditation of Vascular Laboratories make significant errors and have significant variability in the subjective adjustments made during measurements. METHODS: Problems of patient variability were avoided by having the four technologists measure peak velocities from an in vitro pulsatile flow model with unstenosed and 61% stenosed tubes. To evaluate inaccurate angle and sample volume positioning, a probe holder was used in some of the experiments to fix the Doppler angle at 60 degrees. The effect of Doppler gain was studied at three settings--low, ideal, and saturated gains--that were standardized from the ideal level chosen by consensus amongst the technologists. Two waveform display sizes were also investigated. Peak velocity measurement was assessed by comparison with true peak velocities. For each variable studied, average peak velocities were calculated from the 10 measurements made by each technologist and used to find the percent error from the true value, and the coefficient of variation was used to measure the variability. RESULTS: Doppler angle, sample volume placement, and the Doppler gain were the most significant sources of error and variability. Inaccurate angle and placement increased the variability in measurements from 1% to 2% (range) to 4% to 6% for the straight tube and from 1% to 2% to 3% to 9% for the 61% stenosis. The peak velocity error was increased from 9% to 13% to 7% to 28% for the stenosis. Both measurement error and variability were strongly dependent on the Doppler gain level. At low gain, the error was approximately 10% less than the true value and at saturated gain, 20% greater. The display size only affected measurements from the stenosed tube, increasing the error from 9% to 13% to 15% to 24%. CONCLUSIONS: Major factors affecting Doppler peak velocity measurement error and variability were identified. Inaccurate angle and sample volume placement increased the variability. The presence of a stenosis was found to increase the measurement errors. The error was found to depend on the Doppler gain setting, with greater variability at low and saturated gains and on the display size with a stenosis. CLINICAL RELEVANCE: Doppler ultrasound peak velocity measurements are widely used for the diagnostic assessment of the severity of arterial stenoses. However, it is known that these measurements are often in error. We have identified subjective human factors introduced by the technologist and assessed their contribution to peak velocity measurement error and variability. It is to be hoped that by understanding this, improvements in the machine design and measurement methods can be made that will result in improved measurement accuracy and reproducibility.

Artifacts↗

MR imaging of the spine at 3T.

There are many advantages and challenges associated with 3T imaging of the spine. The increase in SNR allows for optimization of diagnostic quality and improved clinical efficiency. PI techniques merge well with high-field technology, which minimizes many of the challenges that are associated with 3T systems. The increase in chemical shift, pulsatile flow, and susceptibility artifact can be mediated with manipulation of imaging parameters. One major challenge that plagued 3T imaging of the spine was the decrease in fluid contrast that was associated with the lengthened T1 relaxation times. This has been resolved essentially for non-contrast spine imaging by using T1 FLAIR, which delineates soft tissue, CSF, disc, and bone interfaces exquisitely well. The optimal postcontrast T1 sequence may not exist yet. Clinical experience dictates that with a combination of T1 FLAIR with or without fat saturation (in one plane) and T1 FSE(in the other plane) no significant enhancing pathology will be missed. Despite the challenges, 3T imaging of the spine provides many improvements over 1.5T systems. These advances can be maximized by use of still evolving technologies and pulse sequence designs.

Artifacts↗

Detection of a systolic pressure threshold for reliable readings in pulse oximetry.

OBJECTIVE: To determine the error of measurement in pulse oximetry with a decreased arterial perfusion and to identify a systolic pressure threshold for (1) initial detection and (2) a reliable reading of oxygen saturation. DESIGN: An experimental clinical prospective study. The study was approved by the local ethics committee. SETTING: Eighteen bed intensive care unit at a University hospital. PATIENTS AND PARTICIPANTS: Twenty-five adult mechanically ventilated and critically ill patients in the ICU during a 3-month period. INTERVENTIONS: A blood pressure cuff at the upper arm (same side as an arterial catheter already in place) was inflated to decrease the arterial pulsatile flow. The cuff was deflated stepwise and the resulting oxygen saturation was measured simultaneously. The error of measurement [delta S = SpO2 (baseline)-SpO2 (indicated)] was calculated for each 5 mmHg of blood pressure (BP). MEASUREMENTS AND RESULTS: Twenty-five patients (9 female, 16 male, 48 +/- 15.9 years old) with a mean SpO2 of 98.3 +/- 1.5% and a BP of 129 +/- 18.4 mmHg participated. The mean systolic BP to obtain initial readings with pulse oximetry was 45.8 +/- 17.7 (range, 25-101) mmHg (35% of the baseline pressure) resulting in lower readings of pulse oximetry (mean -11.5 +/- 13.6%, range -45 to +4%). With a systolic BP > 80 mmHg the mean bias was within the manufacturers limits of +/-2%. CONCLUSIONS: Pulse oximetry is reliable with a systolic blood pressure > 80 mmHg. The lower the BP, the lower the pulse oximetry readings leading to a bias of up to -45%.

Adult↗

M-Mode and 2-dimensional echocardiographic characteristics of the Ionescu-Shiley valve in the mitral and aortic positions.

Using M-mode and 2-dimensional (2-D) echocardiography, ultrasonic features of the Ionescu-Shiley valve were characterized. A number 23 prosthesis was placed in a saline-filled chamber and subjected to pulsatile flow. Production of a linear tear at the base of a cusp resulted in coarse fluttering in the open position, and there was a reduction in the anterior cusp slope. Partial detachment of a cusp from its stent produced high-amplitude low-frequency fluttering during ejection. Alteration of transducer position eliminated the abnormal echoes. Fourteen patients with aortic and 11 with mitral prostheses were studied. There was a close approximation of echographically determined values for the bare stent internal diameter, cusp excursion, and valve orifice diameter compared with the manufacturer's specifications. Random punctiform echoes were noted when the cusps opened. Cusp echoes were superimposed on stent echoes in 21% of patients, and a third cusp was detected in 29%. Two-dimensional echocardiograms of good quality were recorded in the vast majority of subjects. Cusp echoes were smooth and had a consistent motion in both the short and longitudinal axis. Multiple transducer positions were required to delineate prosthetic components with optimal clarity. It is concluded that (1) M-mode and 2-D echocardiography is useful in assessing Ionescu-Shiley valve function, (2) in vitro valve tears or detachment produces characteristic cusp fluttering, (3) careful attention to transducer positions is necessary to record high-quality valve images, and (4) these findings represent a data base for the longitudinal follow-up study of patients with the Ionescu-Shiley valve.

Adult↗

Transpecies heart valve transplant: advanced studies of a bioengineered xeno-autograft.

BACKGROUND: Tissue engineering approaches utilizing biomechanically suitable cell-conductive matrixes should extend xenograft heart valve performance, durability, and growth potential to an extent presently attained only by the pulmonary autograft. To test this hypothesis, we developed an acellular, unfixed porcine aortic valve-based construct. The performance of this valve has been evaluated in vitro under simulated aortic conditions, as a pulmonary valve replacement in sheep, and in aortic and pulmonary valve replacement in humans. METHODS: SynerGraft porcine heart valves (CryoLife Inc, Kennesaw, GA) were constructed from porcine noncoronary aortic valve cusp units consisting of aorta, noncoronary aortic leaflet, and attached anterior mitral leaflet (AML). After treatment to remove all histologically demonstrable leaflet cells and substantially reduce porcine cell-related immunoreactivity, three valve cusps were matched and sewn to form a symmetrical root utilizing the AML remnants as the inflow conduit. SynerGraft valves were evaluated by in vitro hydrodynamics, and by in vivo implants in the right ventricular outflow tract of weanling sheep for up to 336 days. Cryopreserved allograft valves served as control valves in both in vitro and in vivo evaluations. Valves were also implanted as aortic valve replacements in humans. RESULTS: In vitro pulsatile flow testing of the SynerGraft porcine valves demonstrated excellent valve function with large effective orifice areas and low gradients equivalent to a normal human aortic valve. Implants in sheep right ventricular outflow tracts showed stable leaflets with up to 80% of matrix recellularization with host fibroblasts and/or myofibroblasts, and with no leaflet calcification over 150 days, and minimal deposition at 336 days. Echocardiography studies showed normal hemodynamic performance during the implantation period. The human implants have proven functional for over 9 months. CONCLUSIONS: A unique heart valve construct has been engineered to achieve the equivalent of an autograft. Short-term durability of these novel implants demonstrates for the first time the possibility of an engineered autograft.

Animals↗

The totally implantable novacor left ventricular assist system.

The Novacor Left Ventricular Assist System (LVAS) (Novacor Corp, Oakland, CA) was initially console-based and has been available since 1993 in a wearable configuration. It has been successfully used for the past 16 years as a bridge to cardiac transplantation in patients with end-stage congestive heart failure. The Stanford experience represents 53 patients (48 male, 5 female) with a mean age of 44 +/- 13 years (16 to 62) and a mean support time of 56 +/- 76 days (1 to 374). Complications with LVAS use consisted predominantly of bleeding (43%), infection, (30%), and embolic cerebrovascular events (24.5%). Sixty-six percent of the supported patients were successfully bridged to cardiac transplantation. In animal studies, 4 sheep had the totally implantable configuration in place for a cumulative duration of 1 year with 1 animal supported for 260 days. The next generation Novacor LVAS will be small, quiet, and fully implantable without the need for volume compensation. It will also provide physiologic pulsatile flow and will be fail-safe.

Adolescent↗

Influence of sickle hemoglobin polymerization and membrane properties on deformability of sickle erythrocytes in the microcirculation.

The rheological properties of normal erythrocytes appear to be largely determined by those of the red cell membrane. In sickle cell disease, the intracellular polymerization of sickle hemoglobin upon deoxygenation leads to a marked increase in intracellular viscosity and elastic stiffness as well as having indirect effects on the cell membrane. To estimate the components of abnormal cell rheology due to the polymerization process and that due to the membrane abnormalities, we have developed a simple mathematical model of whole cell deformability in narrow vessels. This model uses hydrodynamic lubrication theory to describe the pulsatile flow in the gap between a cell and the vessel wall. The interior of the cell is modeled as a Voigt viscoelastic solid with parameters for the viscous and elastic moduli, while the membrane is assigned an elastic shear modulus. In response to an oscillatory fluid shear stress, the cell--modeled as a cylinder of constant volume and surface area--undergoes a conical deformation which may be calculated. We use published values of normal and sickle cell membrane elastic modulus and of sickle hemoglobin viscous and elastic moduli as a function of oxygen saturation, to estimate normalized tip displacement, d/ho, and relative hydrodynamic resistance, Rr, as a function of polymer fraction of hemoglobin for sickle erythrocytes. These results show the transition from membrane to internal polymer dominance of deformability as oxygen saturation is lowered. More detailed experimental data, including those at other oscillatory frequencies and for cells with higher concentrations of hemoglobin S, are needed to apply fully this approach to understanding the deformability of sickle erythrocytes in the microcirculation. The model should be useful for reconciling the vast and disparate sets of data available on the abnormal properties of sickle cell hemoglobin and sickle erythrocyte membranes, the two main factors that lead to pathology in patients with this disease.

Anemia, Sickle Cell↗

Characterisation of vortex shedding in vascular anastomosis models using pulsed Doppler ultrasound.

Vortex shedding at vascular anastomoses were investigated in vitro using a 20 MHz pulsed-wave Doppler velocimeter. Centreline velocity measurements were made at various axial distances in simplified polyurethane models of proximal and distal end-to-side anastomoses of angles 15, 30, 45, 60 and 80 degrees using pulsatile flow waveforms similar to those in femoropopliteal bypass grafts. The in-phase and quadrature Doppler signals were recorded and the maximum frequency waveform, averaged over 64 cycles, was obtained using short-time Fourier transform. A fourth-order Butterworth low-pass filter was employed to separate the vortex velocity signal from the convective velocity. The vortex signal envelope was calculated using a Hilbert transform method and the vortex amplitude was taken as the maximum of this envelope. The results show that higher vortex amplitude were found in the proximal anastomoses and under resting flow conditions. Although the vortex amplitudes generally increased with angles of anastomosis, they were found to be higher in the 60 degrees than in the 80 degrees proximal anastomosis. The vortex structures were investigated using spectrograms and these show prominent features at 40-50 Hz indicative of the short-duration oscillatory signals during the decelerative phase of systole expected from the passage of vortices. The study indicates that flow disturbances due to vortex shedding may be a common feature in femoropopliteal bypass grafts.

Anastomosis, Surgical↗

The intra-aortic cannula pump: A novel assist device for the acutely failing heart.

OBJECTIVE: The intra-aortic cannula pump is a catheter pump designed to support the acutely failing heart. It expels blood from the left ventricle into the ascending aorta in a pulsatile flow pattern. The aim of the study was to analyze the hemodynamic performance of this new intracardiac support system in acute heart failure. METHODS: A 24F cannula was studied in a series of 16 sheep. Hemodynamic changes were assessed in the nonfailing, the moderately failing, and the severely failing heart. Heart failure was induced by an injection of microspheres into the left anterior descending coronary artery. The cannula was inserted through the aortic arch and introduced through the aortic valve into the left ventricle. RESULTS: Cannula insertion was feasible in all animals. Flow through the intra-aortic cannula flow was increased to a maximum of 3 L/min. No hemodynamic changes were observed in the nonfailing heart. A significant increase in cardiac output was observed in the moderately and severely reduced left ventricle (2.67 +/- 0.7 L to 3.51 +/- 0.83 L; P =.001; and 1.18 +/- 0.77 L to 2.43 +/- 0.44 L; P =.001, respectively). A drop in left atrial pressure was achieved in moderate and severe heart failure (14.1 +/- 5.93 mm Hg to 9.71 +/- 2.63 mm Hg; P =.0001; and 23 +/- 7.16 mm Hg to 11.2 +/- 2.55 mm Hg; P = 0.0001, respectively). Systolic and diastolic systemic blood pressures increased in the severely failing heart (57.3 +/- 12.8 mm Hg to 75.4 +/- 11.2 mm Hg; P =.0001; and 35.6 +/- 8.2 mm Hg to 60 +/- 14.3 mm Hg; P =.0006, respectively). CONCLUSIONS: Hemodynamic data demonstrate the beneficial effects of the intra-aortic cannula pump in moderate and severe heart failure. The intra-aortic cannula pump represents a new modality for the treatment of acute heart failure.

Animals↗

Pelvic examination, tumor marker level, and gray-scale and Doppler sonography in the prediction of pelvic cancer.

OBJECTIVE: To determine the ability of pelvic examination, tumor marker assessment, and transvaginal ultrasonography, with selected use of Doppler ultrasonography, to predict pelvic malignancy. METHODS: Two hundred twenty-six women scheduled for operative removal of a pelvic mass were entered in the study prospectively. Each woman underwent pelvic examination, tumor marker assessment, and transvaginal ultrasonography preoperatively. Women whose gray-scale findings were suspicious for malignancy underwent Doppler ultrasonography. Suspicious findings included masses that were fixed or irregular on pelvic examination; CA 125 level greater than 35 U/mL; elevations in serum lactic dehydrogenase, alpha-fetoprotein, or hCG; and the presence of a substantial solid component on gray-scale ultrasonography. Suspicious Doppler findings included intratumoral color flow, pulsatility index less than 1.0, or resistance index 0.4 or lower. The findings were correlated with the presence of malignancy. RESULTS: If all three indicators (examination, tumor marker assessment, and gray-scale ultrasound findings) were nonsuspicious, 99% of premenopausal women and 100% of postmenopausal women had benign masses. If all three indicators were suspicious, 77% of premenopausal women and 83% of postmenopausal women had malignant tumors. Logistic regression identified ultrasound impression and tumor size to be significant predictors of malignancy in premenopausal women, whereas CA 125 level and ultrasound impression were significant in postmenopausal women. In patients with suspicious gray-scale findings, recategorization based on Doppler findings resulted in inferior diagnostic indices. CONCLUSIONS: Ultrasonographic tumor size and appearance are the best predictors of pelvic malignancy in premenopausal women, whereas CA 125 level and ultrasonographic appearance are the best predictors in postmenopausal women. Neither color nor spectral Doppler is useful in this setting.

Biomarkers, Tumor↗