Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Prosthesis Coloring”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96Linked to original sources

Intracranial aneurysms treated with endovascular coils: detection of recurrences using unenhanced and contrast-enhanced transcranial color-coded duplex sonography.

BACKGROUND AND PURPOSE: Because neck recurrence after endovascular treatment of intracranial aneurysms (IAs) is not uncommon, surveillance to assess long-term stability of occlusion is clearly important. This study evaluated unenhanced and contrast-enhanced transcranial color-coded duplex sonography (TCCS) in detecting refilling of IAs treated with detachable coils. METHODS: Patients with coiled IAs were imaged before and after contrast enhancement. The results were compared with those of a surveillance digital subtraction angiogram (DSA). The operator was blinded to the results of the DSA. Aneurysms were classed as either occluded or with residual flow and quantified as minor, moderate, or extensive. There were 208 studies performed in 4 neurosurgical centers. Of those, 141 studies received ultrasonic contrast enhancement with Levovist, and 68 had an additional enhanced study with SonoVue. RESULTS: We excluded 44 studies. Of the 164 unenhanced studies, TCCS correctly identified 52 of 67 cases defined as completely occluded by DSA (sensitivity 78%; specificity 77%), 13 of 50 aneurysms with minor refilling (sensitivity 26%; specificity 88%), 15 of 27 aneurysms with moderate refilling (sensitivity 56%; specificity 95%), and 9 of 20 aneurysms with extensive refilling (sensitivity 45%; specificity 100%). TCCS correctly identified an additional 10 aneurysms with minor refilling after Levovist enhancement and 3 with SonoVue. Both SonoVue and Levovist enhancement identified an additional 1 aneurysm with moderate refilling and 3 with extensive refilling. CONCLUSIONS: TCCS could be used to selectively monitor IAs, which would reduce the requirement for long-term invasive monitoring. The detection of neck refilling is improved with contrast enhancement.

Adult↗

Artificial iris-lens diaphragm in reconstructive surgery for aniridia and aphakia.

PURPOSE: To determine the efficacy and safety of surgical implantation of artificial iris-lens diaphragm in patients with anatomic or functional iris deficiencies, aphakia or cataract. SETTING: Svyatoslav Fyodorov MNTK Eye Microsurgery, Cheboksary, Russia. METHODS: Twenty eyes of 19 consecutive patients with combined iris and lens pathology of traumatic or congenital etiology were identified for an interventional noncomparative case series. The newly proposed model of an elastic iris-lens diaphragm with a colored haptic and additional support elements was implanted using various fixation approaches. RESULTS: Fifteen eyes (75%) experienced improvement in corrected visual acuities. The best spectacle-corrected visual acuity (BSCVA) in 2 eyes did not change, while the uncorrected visual acuity (UCVA) in these eyes increased. There were 3 eyes in which BSCVA deteriorated with no change or even slight improvement in UCVA. All patients were satisfied with the cosmetic results of the surgery and reported a decrease in glare and photophobia. There was 1 intraoperative complication of vitreous hemorrhage. Postoperatively, 2 cases of hyphema, 1 case of ciliochoroidal detachment, 4 eyes with exaggerated immediate postoperative reaction, and 1 eye with persistent low-grade cyclitis were observed. In 1 eye, there was persistent intraocular pressure rise. One eye showed signs of cystoid macular edema. No iris-lens diaphragm decentrations and no new or extensions of old retinal detachments were seen during the follow-up period. CONCLUSIONS: Artificial iris-lens diaphragm implantation effectively improved postoperative outcomes by correcting aphakia, reducing glare disability, and addressing cosmetic issues faced by iris-deficient, and aphakic or cataract patients. Although the iris-lens diaphragm appears to be safe, long-term results must be clarified in studies with longer follow-up and a larger patient population.

Adolescent↗

Long-term cardiac allograft valves after heart transplant are functionally and structurally preserved, in contrast to homografts and bioprostheses.

BACKGROUND AND AIM OF THE STUDY: Homograft valves undergo degenerative changes over time, which finally lead to functional deterioration. Immunological events are believed to play a pivotal role in this process. To further evaluate this hypothesis, the valvular morphology and function, as well as comorbidities predisposing to deteriorative processes, were evaluated in patients who had undergone heart transplant more than 10 years previously. METHODS: In a consecutive cohort of 146 patients (125 males, 21 females; mean age at transplant 43.8 +/- 11.2 years), heart and valve function were assessed by color Doppler echocardiography at a mean of 5306 +/- 987 days after heart transplant. Evaluated parameters included chamber dimensions, cardiac function, valvular morphology/function, and concomitant diseases. RESULTS: Atrial and ventricular dimensions were within normal ranges for the left atrium (LA; n=7), right atrium (RA; n=7), left ventricle (LV; n=143) and right ventricle (RV; n=119). Slight enlargements occurred in the LA (n=138), RA (n=137), LV (n=1) and RV (n=11), while significant enlargements were seen in the LA (n=1), RA (n=2), LV (n=2), and RV (n=16). With regard to cardiac function, the ejection fraction (EF) was 63.9 +/- 4.9%, left ventricular isovolumic relaxation time (IVRT) 85.04 +/- 14.64 ms, fractional shortening (FS) 34 +/- 12%, and pulmonary artery systolic pressure (PASP) 29.81 +/- 6.4 mmHg. Valvular regurgitation (grade > or =2) was present in 34 patients (31 tricuspid valves, three mitral valves). No patients presented with aortic valve regurgitation. Concomitant conditions with a potential impact on calcium balance/valvular deterioration included immunologic/chronic inflammatory diseases (n=6), malignancies (n=12), kidney (n=41), cardiovascular system (n=39) and thyroid/parathyroid (n=12). CONCLUSION: During the long term after heart transplant, heart valves were characterized by normal morphology and function in the majority of cases. Although most patients presented with concomitant conditions strongly predisposing for valvular deterioration/calcification, sole immunosuppressive/anti-inflammatory therapy appears to prevent these processes in heart transplant patients.

Adult↗

Suprarenal filter placement.

PURPOSE: This study was undertaken to determine the clinical outcomes for patients with Greenfield filters placed in the suprarenal (SR) inferior vena cava (IVC). METHODS: We collected data prospectively from annual follow-up evaluations of patients with filters. Patients underwent venous color-flow duplex examinations of the IVC and lower extremities, abdominal radiographs, and physical assessment. The outcomes for those patients with filters in the SR IVC were compared with the outcomes previously reported and with the outcomes for patients with filters in the infrarenal cava. RESULTS: SR placement accounted for 7.6% (148/1932) of all filter placements. Follow-up data were available for 73 placements, or 49%. No cases of renal dysfunction were related to filter placement. The rate of recurrent pulmonary embolism (PE) was 8%, and the rate of long-term caval occlusion was 2.7%. These rates did not differ statistically from the rates for patients with infrarenal filters (P > .05). Male patients tended to be older by 15 years, to have more recurrent PE, and to experience more filter migration (6 vs 2 mm). Failure of SR filters to prevent PE was associated statistically with the primary indication for placement. Recurrent PE was the indication in 5 of 6 patients who sustained PE after SR filter placement (P = .007). Filter limb fracture was seen only with the stainless-steel Greenfield filter. CONCLUSION: Greenfield filters placed above the renal vein provide protection from PE with a minimal risk of occlusion. Twenty-five years of experience with Greenfield filters shows that they are safe and effective both in young female patients of child-bearing potential and in all patients with appropriate indications for SR placement.

Female↗

Left atrial appendage dysfunction: a cause of thrombosis? Evidence by transesophageal echocardiography-Doppler studies.

The blood flow velocity patterns within the left atrial appendage were studied by transesophageal color flow imaging and pulsed Doppler in 84 patients. At the time of the study, 57 of the patients were in sinus rhythm, 25 were in atrial fibrillation, and two were in atrial flutter. The relationships between atrial rhythm, blood flow pattern and the presence/absence of spontaneous echocardiographic contrast or thrombus within the appendage were investigated. Transesophageal echocardiography allowed recording of blood flow velocities in 81 of the 84 patients studied. In 51 of the 55 patients in sinus rhythm the pulsed Doppler study showed a biphasic blood flow pattern, whereas a multiphasic pattern was found in the two patients with atrial flutter and in 14 patients with atrial fibrillation. In four patients with sinus rhythm and 10 patients with atrial fibrillation, no significant blood flow velocity could be detected. Thrombus or spontaneous echocardiographic contrast were found within the left atrial appendage in 20 patients, and in all these patients blood flow was either absent or significantly reduced. Our findings indicate that an absent or low blood flow velocity within the left atrial appendage represents a predisposing factor for thrombosis. Isolated left atrial appendage dysfunction has been documented in four patients during sinus rhythm, which may lead to thrombosis. This observation may offer an explanation for cardioembolic events that occur occasionally in patients without apparent heart disease and sinus rhythm.

Adult↗

Patency of infrarenal aortic side branches determines early aneurysm sac behavior after endovascular repair.

In this study we sought to determine whether initial abdominal aortic aneurysm (AAA) sac anatomy, morphology, and side branch patency influence changes in aneurysm size and development of endoleak following endovascular repair. A blinded, retrospective review of preintervention CT scans and angiograms was conducted on 70 consecutive patients treated for infrarenal AAA (mean size 6.0 +/- 0.8 cm) by AneuRx stent-graft exclusion. Initial AAA diameter and side branch (inferior mesenteric artery [IMA], lumbar artery pair) patency, AAA clot/sac diameter ratio, wall thrombus and calcification distributions, attachment site anatomy, endograft size, and other clinical parameters were correlated with postoperative persistent side branch patency, presence of type II endoleak, and change in AAA diameter (increase/decrease ? 5 mm) using contingency table analyses. Patients underwent CT scanning and/or color duplex imaging at 1 month and at 3 (with endoleak) or 6 (without) month intervals postoperatively with 50 patients followed beyond 6 months (mean follow-up 11 +/- 7 months). The majority of patients possessed patent side branches prior to intervention (lumbar [n = 60, 86%], IMA [n = 45, 64%]). Development of type II endoleak or persistence of side branches could not be predicted (p > 0.05) from preoperative AAA side branch patency or any of the other initial anatomic AAA variables. On serial post-repair CT or duplex cans, 42% (19/45) of IMAs and 27% (16/60) of lumbar artery pairs remained patent. For patients followed beyond 6 months, type II endoleaks persisted in half (13/25) of the patients with patent side branches with roughly equal proportions fed by IMA and lumbar sources. Persistent side branches or presence of type II endoleak was associated with AAA expansion or the failure of aneurysm size diminution after endografting (p <0.01). Aneurysm sac regression was most likely in the absence of endoleak and patent side branches. We conclude that persistent side branch patency not only fuels development of type II endoleak but also influences early aneurysm sac behavior after endovascular repair. Optimal anatomic patient selection for endografting may not be possible on the basis of our initial experience, since preoperative AAA variables did not predict persistence of side branches or type II endoleaks.

Aged↗

Transjugular intrahepatic portosystemic shunt creation with the Viatorr expanded polytetrafluoroethylene-covered stent-graft.

PURPOSE: To evaluate the midterm clinical results and patency of transjugular portosystemic shunts (TIPS) created with a commercially available expanded polytetrafluoroethylene (ePTFE)-covered stent-graft based on angiographic and ultrasonographic (US) criteria in a series of 71 patients. MATERIALS AND METHODS: Seventy-one patients (61 men, 10 women; mean age, 58.6 years, range, 25-78 years) were included in this series, which was performed in two centers. Indications for TIPS creation were refractory ascites (n = 44) and recurrent esophageal bleeding (n = 27). Ten patients had Child-Pugh class A liver cirrhosis, 43 had class B disease, and 18 had class C disease. Underlying liver diseases were alcoholic cirrhosis (n = 58), cirrhosis resulting from hepatitis (n = 9), cryptogenic cirrhosis (n = 3), and Budd-Chiari syndrome (n = 1). TIPS were created with commercially available ePTFE-covered stent-grafts in all patients. The diameters of the stent-grafts were 10 mm in 58 patients and 8 mm in the remaining 13 patients. Follow-up included clinical examination and color-coded US after 5 days, 1, 3, and 6 months, and every 6 months thereafter. Shunt angiograms were obtained every 6 months. Median follow-up was 16.3 months (range, 3.8-26.6 months). RESULTS: TIPS creation was successful in all patients without complications, and effective portal decompression was observed with a reduction of the mean portal gradient from 19 mm Hg to 6 mm Hg before and after TIPS creation. Four shunt occlusions were observed after 5 days, 2 months, 3 months, and 6 months. Shunt stenosis was observed in three patients at the hepatic vein, which was not fully covered by the stent-graft, after 6 months (n = 2) and 12 months, and at the portal side after 1 month in a patient who initially had portal vein thrombosis. The repeat intervention rate was 11.3%. The primary patency rates were 87.4% (95% CI, 77.7%-97.1%) after 6 months and 80.8% (95% CI, 68.2%-93.4%) after 12 months. The rate of de novo or deteriorated hepatic encephalopathy was 31%. The recurrent bleeding rate was 3.7% (one of 27), and ascites improved or resolved in 64% of patients after 1 month. CONCLUSION: TIPS patency can be significantly increased if the ePTFE-covered stent-graft is used for shunt creation. The increased shunt patency contributes to low repeat intervention and recurrent bleeding rates. The rate of hepatic encephalopathy is within the range of previously reported rates.

Adult↗

Prospective, randomized study of external jugular vein patch versus polytetrafluoroethylene patch during carotid endarterectomy: perioperative and long-term results.

OBJECTIVES: The purpose of this study was to evaluate the relative risks and advantages of using external jugular vein (EJV) patch, compared with polytetrafluoroethylene (PTFE) patch, during carotid endarterectomy. The primary end point was the relevant neurologic complication rate (RNCR; fatal or disabling stroke) at any time during follow-up. Secondary end points included stroke-free survival, 30-day and long-term mortality, recurrent stenosis rate (> or =50%), occlusion, patch infection, aneurysm formation, and other local complications. METHODS: The study, a prospective randomized clinical trial carried out at a single center, was divided into two 3-year phases: December 1996 to March 1999, when patients were enrolled, and March 1999 to March 2002, which was the follow-up period. Inclusion criteria included an external jugular vein suitable for patching, defined as vein diameter 3 mm or larger and absence of collateral vessels noted on preoperative color duplex ultrasound scans. Patients were prospectively randomized 1:1 to receive either the EJV (n = 80; group A) or synthetic (n = 80; group B) patch. RESULTS: Carotid endarterectomy and patching was performed by one surgeon. At 30 months the RNCR-free rate, analyzed with the Kaplan-Meier method, was 98.7% for group A (1 ipsilateral lethal stroke) and 94.6% for group B (4 ipsilateral disabling strokes), and remained stable to 60 months. No statistical difference was observed with the log-rank test. Stroke-free survival rate was 100% for group A and 98.7% for group B at 1 year, 98.7% for group A and 93.6% for group B (1 ipsilateral minor stroke) at 30 months, and was unchanged at 60 months. Life table analysis demonstrated freedom from significant recurrent stenosis (> or =50%) of 97.5% for both groups at 6 months, 93.6% for group A and 92.2% for group B at 30 months, and 90.2% for group A and 86.7% for group B at 60 months. No statistical difference was observed with the log-rank test. In no patients was recurrent stenosis greater than 70%. No aneurysm formation was noted during follow-up. CONCLUSIONS: We can conclude, with the power limitation of the study, that carotid endarterectomy can be safely performed with either the EJV or PTFE patch. Advantages of the EJV for carotid angioplasty include no cost for material, low risk for graft infection, and preservation of the saphenous vein.

Aged↗

Insensitivity of color Doppler flow imaging for detection of acute calf deep venous thrombosis in asymptomatic postoperative patients.

PURPOSE: Although color Doppler flow imaging (CDFI) has been shown to accurately depict calf vein thrombosis in symptomatic patients, this technique has not been proved accurate for detection of calf vein thrombosis in a population restricted to asymptomatic postoperative patients. PATIENTS AND METHODS: To evaluate the accuracy of CDFI in asymptomatic postoperative patients, both CDFI and contrast venography were performed on 78 limbs of 76 patients without symptoms of deep venous thrombosis (DVT) who had undergone either hip or knee replacement. CDFI and venographic examination were interpreted blindly with respect to the results of the other modality or clinical findings. Venography was the standard for comparison of results. RESULTS: Fifty-six percent of CDFI examinations of the calf vein were technically adequate. The remaining studies were compromised technically by limb swelling and/or obesity. For the technically adequate CDFI studies, calf vein thrombosis was detected in eight of 10 patients. Calculated sensitivity in this cohort was 80%, and specificity was 97%. The sensitivity of CDFI for acute calf DVT in all patients, regardless of image quality, was 42%. CONCLUSION: These observations suggest that state-of-the-art CDFI is not an accurate examination for acute calf vein DVT in asymptomatic postoperative patients. CDFI is associated with a high rate of technically compromised studies and relatively low sensitivity in studies that are deemed technically satisfactory. These observations do not preclude the use of CDFI in postoperative patients for detection of thrombus extension into the popliteal vein or for detecting thrombosis of more proximal lower extremity veins.

Female↗

[Early results of atrial septal defect closure with the Amplatzer Septal Occluder are impacted by tricuspid insufficiency].

OBJECTIVE: Our study reports the results of a comparison of transcatheter closure of secundum atrial septal defect (ASD) using the Amplatzer Septal Occluder (ASO) in patients with and without tricuspid insufficiency. METHODS: Consecutive 27 adult patients (20 females, 7 males) with a mean age of 41.1 +/- 13.3 (range 18-62) years having an ASD II and a transcatheter closure between December 2000 and December 2002 were analyzed. All the patients had an isolated secundum ASD with a significant left-to-right shunt (ratio of pulmonary to systemic blood flow or Qp:Qs >1.5:1). Patients were divided in two groups: group I--without tricuspid abnormalities (8 patients, 29.6%), group II--patients with tricuspid insufficiency I-III stage, (19 patients, 70.4%). Transthoracic color Doppler echocardiographic study was performed in all patients before discharge and was repeated one month after discharge. RESULTS: The mean age, the diameter of defect, the degree of left-to-right shunt, the diameter of implanted device were comparable in both groups. Before implantation the dimension of right heart cavities differed between groups. The right ventricular dimension was larger in group II (mean 36.2 mm vs. 29.1 mm; p<0.009), the right atrium diameter was larger in group II (46.2 mm vs. 24.3 mm; p<0.007). Pulmonary artery systolic pressure before the procedure was higher in group II (36.6 mmHg vs. 20.43 mmHg; p<0.006). The ASO device was successfully implanted in all the patients. At one month follow-up septal motion abnormalities normalized in all patients in both groups. The mean decrease of right atrium diameter in group I was 6.2 mm (range 1.5-12 mm) compared to 9.6 mm (range 2-20) in group II, (p<0.001), the mean decrease of right ventricular diameter in group I was 5.8 mm (range 2-8 mm) compared to 3.1 mm (range 1-5.9) in group II, (p<0.006). CONCLUSIONS: Short-term follow-up demonstrated excellent results of ASD closure in both groups. In one month follow-up the decrease of right cavities dimensions was significantly higher in the patients without tricuspid abnormalities. The pulmonary artery systolic pressure before ASD closure was significantly higher in the patients with tricuspid abnormality.

Adult↗

[Early haemodynamic changes after transcatheter closure of atrial septal defect].

OBJECTIVE: To evaluate the outcomes of transcatheter closure of secundum atrial septal defect (ASD) using the Amplatzer Septal Occluder (ASO). METHODS: Between December 2000 and December 2002, 27 adult patients (20 females, 7 males) with a mean age of 41.1 +/- 13.3 (range 18-62) years were enrolled for an attempt at ASD closure with the ASO device. All patients had an isolated secundum ASD with a large left-to-right shunt (ratio of pulmonary to systemic blood flow or Qp:Qs >1.5:1). Transthoracic color Doppler echocardiographic examination was performed on all patients before procedure, 24 hours, 1 and 6 months after surgery. Clinical observation (NYHA class) was performed 1 and 6 months after surgery. RESULTS: The ASO device was successfully implanted in all patients (procedure time 19-63 minutes, median 43 minutes, fluoroscopy time 4-40 minutes, median 12.6 minutes), with only 3 patients with a trivial residual shunt. The defect echo diameter was 14.2 +/- 4.3 (7-24). At one month of follow-up transthoracic echocardiography showed that the device was correctly positioned in all cases and no predictors for a residual shunt were identified. Residual trivial shunt in one month follow-up was shaded in 3 patients. Paradoxical septal motion abnormalities normalized in all patients. The right ventricular dimension evaluated by 2D echocardiography decreased in 20 pts (74.1%), mean 5.0 +/- 3.4 mm (range 1.5-8), the right atrium dimension decreased in 21 pts (77.8%), mean 8.65 +/- 4.3 mm (range 2-20) and the left atrium dimension decreased in 15 pts (55.6%), mean 6.36 +/- 3 mm (range 2-21). We didn't find correlations between ratio of left-to-right shunt before ASD closure and the decrease of right heart dimension as well as the decrease of pulmonary artery systolic pressure. CONCLUSIONS: Transcatheter closure of secundum ASD using the ASO is a safe and effective procedure, with excellent short-term follow-up results. During one month observation it caused partial normalization of echocardiographic parameters.

Adult↗

An economic appraisal of lower extremity bypass graft maintenance.

OBJECTIVE: Infrainguinal graft surveillance leads to intervention on the basis of duplex-identified stenoses. We have become increasingly concerned about the high frequency with which such revisions are required to maximize graft patency and limb salvage rates. The economic implications of these procedures have not been carefully analyzed or justified. METHODS: We retrospectively reviewed 155 consecutive autogenous infrainguinal bypass grafts performed for chronic leg ischemia in 141 patients. All patients were enrolled in a prospective surveillance program using color flow duplex imaging. Full economic appraisal (cost analysis, cost-effect analysis, and cost-benefit analysis) was performed for all graft surveillance and limb salvage-related interventions through use of standard accounting and valuation techniques. RESULTS: Mean follow-up was 27 months. Five-year assisted primary patency (72%) and limb salvage rates (91%) were calculated by means of life table analysis. A total of 61 grafts required 86 revisions. Within 1 year of implantation, 36% of the grafts required revision. During this first year, the mean cost per graft enrolled was $9417. Time intervals after the initial year demonstrated a reduced annual revision rate (6%) and cost ($1725 per graft). The mean 5-year cost of graft maintenance ($16,318) approached that of the initial bypass graft ($19,331). The sum of the initial cost of bypass graft and 5-year graft maintenance cost ($35,649) was similar to the cost of amputation ($36,273). Grafts revised for duplex-detected stenoses (n = 46), in comparison with those revised after thrombosis (n = 15), had an improved 1-year patency (93% vs 57%; P <.01), required fewer amputations (2% vs 33%; P <.01), less frequently required multiple graft revisions (P =.06), and generated fewer expenses (at 12 months after revision, $17,688 vs $45,252, P <.01). CONCLUSION: The cost associated with graft maintenance is significant, particularly within the first year, and demands consideration. Revision of a duplex-identified stenosis was significantly less costly than revision after graft thrombosis. Compared with the cost of limb amputation, limb salvage-related expenses appear to be justified.

Aged↗

Hemobahn stent-grafts for treatment of femoropopliteal arterial obstructions: midterm results of a prospective trial.

PURPOSE: To report a prospective study to evaluate safety, effectiveness, and midterm patency of self-expanding stent-grafts in patients with femoropopliteal occlusive disease. MATERIALS AND METHODS: Sixty-three Hemobahn stent-grafts were used in 52 patients for treatment of medium- or long-segment (>3 cm) occlusions (82.7%) and stenoses (17.3%) of the femoropopliteal artery. The mean length of vessel segments covered was 10.9 cm +/- 5.13. Follow-up with documentation of clinical symptoms, assessment of Rutherford clinical stage of peripheral vascular disease, and color-coded duplex sonography was performed at discharge, at 1, 3, 6, 12, 18, and 24 months after implantation, and yearly thereafter. Mean follow-up duration was 23.8 months +/- 6.9 (range, 8-36 mo). Follow-up data at 12 and 24 months after treatment were available for 47 of 52 (90.4%) and 31 of 52 patients (59.6%), respectively. RESULTS: Device implantation was technically successful in all 52 patients, yielding an overall technical success rate of 100%. Procedure-related complications were observed in 12 of 52 patients (23.1%) and consisted of distal embolization (n = 4, 7.7%), minor groin hematoma (n = 7, 13.5%), and arteriovenous fistula (n = 1, 1.9%), but prolonged hospitalization and further medical, interventional, or surgical measures were not required. Stent-graft placement induced an initial improvement of the mean resting ankle-brachial index from 0.54 +/- 0.12 to 0.89 +/- 0.14 (P <.01). Primary patency rates at 12 and 24 months were 78.4% +/- 5.8 and 74.1% +/- 6.2, respectively. Primary assisted patency rates were 82.4% +/- 5.3 at 12 months and 80.3% +/- 5.6 at 24 months. Secondary patency rates at 12 and 24 months were 88.3% +/- 4.5 and 83.2% +/- 5.5, respectively. There was no significant difference (log-rank test, P >.3) between primary patency rates in patients grouped according to lengths of implanted grafts (ie, length of the treated lesions). CONCLUSION: Endovascular placement of Hemobahn stent-grafts for percutaneous treatment of medium- to long-segment high-grade stenoses and occlusions of the femoropopliteal artery is a safe procedure with excellent initial success rates and promising midterm results.

Aged↗

Kinetic analysis of tear interference images in aqueous tear deficiency dry eye before and after punctal occlusion.

PURPOSE: Kinetic analysis of sequential tear interference images was used to investigate how the precorneal lipid film spread and distributed in aqueous tear deficiency (ATD) dry eye. METHODS: One eye of 17 patients with ATD was randomly selected for this noncomparative case series. Twelve patients also had noninflamed meibomian gland dysfunction (MGD). Sequential images were digitized and analyzed on computer. Data were further compared in 9 of the 17 cases before and after punctal occlusion (PO). Outcome measures included speed and pattern of lipid spread and resultant lipid layer thickness in the superior, central, and inferior cornea. Intensity and red/green/blue (RGB) color spectra of the tear interference image were compared before and after PO. RESULTS: After lid blinking, it took a longer time (2.2 +/- 1.1 second) to reach a stable lipid film in all eyes with ATD compared with normal subjects (P < 0.0001). Because of this retarded spread, the thickest lipid film was located at the inferior cornea adjacent to the lid margin, with a gradient spreading toward the superior cornea (P = 0.01). As a result, the lipid film was thinner than normal on the superior cornea in 10 of 17 (59%) ATD eyes. Fifteen of 17 eyes (88%) showed vertical streaking, rather than a normal horizontal propagation pattern on the superior cornea. Such a lipid-deficient state and uneven distribution did not correlate with the presence or absence of MGD. The lipid spread time was shortened (P = 0.008), the distribution of the lipid film was more even, and the thickness approached normal in all nine eyes after PO. CONCLUSIONS: In this study, kinetic analysis of tear interference images provided evidence that retardation of lipid spread is, but MGD is not, the main reason for the increased thickness of precorneal lipid film in the inferior cornea of eyes with ATD. As a result, lipid film is deficient in the superior cornea and unevenly distributed, further destabilizing the tear film. The fact that PO significantly improves lipid spread, evenness, and thickness suggests that the performance of lipid film is also dictated by the amount of aqueous tear fluid. These findings provide new insight into the interaction between the lipid film and the aqueous tear fluid.

Adult↗

Distal revascularization-interval ligation for limb salvage and maintenance of dialysis access in ischemic steal syndrome.

PURPOSE: Traditional options for treating ischemic steal syndrome related to a functioning dialysis access graft or fistula include banding or ligation. Unfortunately, these techniques usually result in inconsistent limb salvage, loss of a functional access, or both. We report our experience with an alternative method of limb revascularization that eliminates steal while maintaining continuous dialysis access. METHODS: Patients who had critical limb ischemia and functioning arteriovenous fistulae (AVF) underwent color-flow duplex scanning, digital photoplethysmography, and arteriography. Arterial ligation distal to the AVF origin eliminated the steal physiologic mechanism while arterial bypass grafting from above to below the AVF revascularized the extremity (distal revascularization-interval ligation [DRIL] procedure). RESULTS: From March 1994 through December 1996, 21 patients with functioning extremity AVFs presented with critical ischemia and steal syndrome. Eleven patients had chronic ischemia with rest pain, paresthesias, or ulcerations related to nine native fistulae (six brachiocephalic, two basilic vein transpositions, one radiocephalic) and two prosthetic bridge grafts (one upper arm, one lower extremity). Acute ischemia developed in 10 patients related to three native fistulae (two brachiocephalic, one radiocephalic) and seven prosthetic bridge grafts (three forearm, three lower extremity, one upper arm). All 21 patients were treated with the DRIL technique. Three of these patients required treatment for ischemia at the time of AVF construction. Nineteen of 21 bypass procedures were performed with autogenous vein, including nine brachial-brachial, three brachial-radial, two radial-radial, two brachial-ulnar, one popliteal-popliteal, one femoral-popliteal, and one femoral-peroneal. Polytetrafluoroethylene grafts were used for one external iliac-popliteal bypass graft and one axillary-brachial bypass graft. Limb salvage and maintenance of a functional fistula were achieved in 100% and 94%, respectively, at 18 months by life-table analysis. CONCLUSION: The DRIL technique reliably restores antegrade flow to the ischemic limb, eliminates the potential pathway for the steal physiologic mechanism, and maintains continuous dialysis access in these difficult patients.

Aged↗

Changes in mitral annular and left ventricular dimensions and left ventricular pressure-volume relations after off-pump treatment of mitral regurgitation with the Coapsys device.

OBJECTIVE: The objective of this study was to evaluate the changes in mitral annular and left ventricular dimensions and left ventricular pressure-volume relations produced by the Myocor Coapsys device that has been developed to treat functional mitral regurgitation (MR) off-pump. METHODS: The Coapsys device, which consists of anterior and posterior epicardial pads connected by a sub-valvular chord, was implanted in seven dogs with functional MR resulting from pacing induced cardiomyopathy. The Coapsys device was then sized by drawing the posterior leaflet and annulus toward the anterior leaflet. During sizing, MR grade was assessed using color flow Doppler echocardiography. Final device size was selected when MR was eliminated or minimized. Following implantation, heart failure was maintained by continued pacing for a period of 8 weeks. Mitral annular and left ventricular dimensions and left ventricular pressure-volume relations were evaluated by two-dimensional echocardiography and a conductance catheter, respectively, at pre-sizing, post-sizing, and after 8 weeks. RESULTS: All implants were performed on beating hearts without cardiopulmonary bypass. Mean MR grade was reduced from 2.9+/-0.7 at pre-sizing to 0.7+/-0.8 at post-sizing (P<0.001), and was maintained at 0.8+/-0.8 after 8 weeks (P<0.01). The septal-lateral dimensions were significantly reduced at both mitral annular level [2.4+/-0.2 cm at pre-sizing, 1.5+/-0.3 cm at post-sizing (P<0.001) and 1.8+/-0.3 cm after 8 weeks (P<0.05)] and mid-papillary level [4.1+/-0.4 cm at pre-sizing, 2.4+/-0.2 cm at post-sizing (P<0.001) and 3.3+/-0.4 cm after 8 weeks (P<0.001)]. The end-systolic pressure-volume relation shifted leftward at post-sizing with a significantly steeper slope (P=0.03). There was a significant (P=0.03) leftward shift of the end-diastolic pressure-volume relation at post-sizing. After 8 weeks, these changes in pressure-volume relations tended to return to pre-sizing relations. CONCLUSIONS: The Coapsys device significantly reduced MR by treating both the mitral annular dilatation and the papillary muscle displacement. Despite these significant dimensional changes, the Coapsys device did not negatively affect the left ventricular pressure-volume relations.

Animals↗

[Doppler evaluation of porcine mitral valve dysfunction].

Seventy patients with bioprosthetic mitral valve were examined to study the applicability of the Doppler techniques including pulsed, continuous wave and color Doppler echocardiography in diagnosing and evaluating the severity of prosthetic valve dysfunction. The study population consisted of 70 patients who underwent mitral valve replacement (45 patients with Hancock valve, 13 with Angell-Shiley valve, 10 with Carpentier-Edwards valve). The dysfunctions were transvalvular regurgitation in 20 instances and paravalvular regurgitation in three, all of which were confirmed at surgery. A control group of 47 patients with the normally functioning porcine prosthetic mitral valve were also studied. Diastolic transmitral flow patterns were recorded from parasternal and apical approaches using color Doppler echocardiography, and the direction of the flow was definitely identified on the flow image. Transmitral flow signals spread from the mitral orifice to the mid-portion of the interventricular septum, and its direction was perpendicular toward the mitral ring in all cases. Flow velocity patterns in the left ventricle and atrium were recorded in the apical long-axis view of the left ventricle or apical four-chamber view using pulsed (high pulse repetition frequency) and continuous wave Doppler techniques. Two dynamic alterations in patients with the porcine mitral valve were evaluated from 1) the peak velocity and pressure half time (PHT) of transmitral flow in early diastole, and 2) the regurgitant jet in the left atrium indicating transvalvular or paravalvular regurgitation. The results were as follows: 1. Normally functioning porcine mitral valves were characterized by peak velocities (PV) less than or equal to 1.82 (mean +/- SD 1.44 +/- 0.27) m/sec and PHT less than or equal to 180 (mean +/- SD: 135 +/- 30) msec. In 23 patients with prosthetic valve dysfunction documented at surgery, peak velocity (mean +/- SD 2.23 +/- 0.19 m/sec) was significantly greater (p less than .001) than that of patients in the normally functioning prosthetic valves, and PHT ranged from 135 to 340 msec (mean +/- SD: 226 +/- 81 msec). 2. Among the 23 patients with porcine valve dysfunction, a harmonic striped pattern were recorded at the mitral valve levels in eight patients. All these patients had a musical murmur, and their peak velocity was more than 2.0 m/sec, but the PHT was less than 180 msec in seven patients. In these patients, valvular tears without calcification were confirmed at surgery.(ABSTRACT TRUNCATED AT 400 WORDS)

Animals↗

[Late complications of valve replacement: the benefits of non-invasive assessment].

Non-invasive techniques were assessed for their capabilities of detecting prosthetic valve malfunctions in 70 consecutive patients with angiographically-documented or surgically-proven prosthetic valve dysfunction. Their 74 dysfunctioning valves were studied using phonocardiography, M-mode and two-dimensional echocardiography and Doppler methods, including pulsed and continuous wave (CW) Doppler echocardiography and two-dimensional Doppler color flow mapping (2DD). These results were compared among the examinations, and also compared between 43 patients with 44 dysfunctioning mechanical valves and 27 patients with 30 dysfunctioning bioprosthetic valves. Symptoms related to valve malfunction were recognized in all patients with prosthetic valve endocarditis and in all patients but one with stenotic condition. In patients with valvular regurgitation, however, symptoms were observed in only six of the 21 patients with mechanical prostheses and in 12 of the 25 patients with bioprosthetic valves (p less than 0.01). Among 43 patients with 44 mechanical valve dysfunctions, the sensitivities of phonocardiography, M-mode and two-dimensional echocardiography and Doppler techniques were 85, 65 and 86 percent, respectively, in 20 patients with stenosis; 100, 57 and 80 percent in seven patients with transvalvular regurgitation; and 100, 50 and 100 percent in 14 patients with paravalvular regurgitation. Similarly, among 27 patients with bioprosthetic valve dysfunctions, the sensitivities of phonocardiography, M-mode and two-dimensional echocardiography and Doppler methods were 67, 100 and 100 percent, respectively, in three patients with stenotic condition; 85, 65 and 100 percent in 20 patients with transvalvular regurgitation; and 60, 40 and 100 percent in five patients with paravalvular regurgitation. Furthermore, 26 of the 27 patients with malfunctioning mechanical valves and 20 of the 24 patients with malfunctioning bioprostheses had abnormal findings using more than two techniques. In addition, each patient had at least one abnormal finding. In conclusion, malfunctioning mechanical or bioprosthetic prostheses could be detected using non-invasive techniques. The combined use of phonocardiography, M-mode and two-dimensional echocardiography and Doppler techniques is most helpful in detecting malfunctioning prostheses.

Adult↗