Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Microscopy”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96Linked to original sources

Combined scanning electrochemical/optical microscopy with shear force and current feedback.

A technique that combines scanning electrochemical microscopy (SECM) and scanning optical microscopy (OM) was developed. Simultaneous scanning electrochemical/optical microscopy (SECM/OM) was performed by a special probe tip, which consists of an optical fiber core for light passage, surrounded by a gold ring electrode, and an outermost electrophoretic insulating sheath, with the tip attached to a tuning fork. To regulate the tip-substrate distance, either the shear force or the SECM tip current was employed as the feedback signal. The application of a quartz crystal tuning fork (32.768 kHz) for sensing shear force allowed simultaneous topographic, along with SECM and optical imaging in a constant-force mode. The capability of this technique was confirmed by obtaining simultaneously, for the first time, topographic, electrochemical, and optical images of an interdigitated array electrode. Current feedback from SECM also provided simultaneous electrochemical and optical images of relatively soft samples, such as a polycarbonate membrane filter and living diatoms in a constant-current mode. This mode should be useful in mapping the biochemical activity of a living cell.

Cell Membrane↗

Microspotting streptavidin and double-stranded DNA arrays on gold for high-throughput studies of protein-DNA interactions by surface plasmon resonance microscopy.

We present two strategies for microspotting 10 x 12 arrays of double-stranded DNAs (dsDNAs) onto a gold-coated glass slide for high-throughput studies of protein-DNA interactions by surface plasmon resonance (SPR) microscopy. Both methods use streptavidin (SA) as a linker layer between a biotin-containing mixed self-assembled monolayer (SAM) and biotinylated dsDNAs to produce arrays with high packing density. The primary mixed SAM is produced from biotin- and oligo(ethylene glycol)-terminated thiols bonded as thiolates onto the gold surface. In the first method, a robotic microspotter is used to deliver nanoliter droplets of dsDNA solution onto a uniform layer of this SA ( approximately 2 x 10(12) SA/cm(2)). SPR microscopy shows a density of (5-6) x 10(11) dsDNA/cm(2) (0.2-0.3 dsDNA/SA) in the array elements. The second method uses instead a microspotted array of this SA linker layer, onto which the microspots of dsDNA are added with spatial registry. SPR microscopy before addition of the dsDNA shows a SA coverage of 2 x 10(12) SA/cm(2) within the spots and a dsDNA density of 8.5 +/- 3.5 x 10(11) dsDNA/cm(2) (0.3-0.7 dsDNA/SA, depending on the length of dsDNA) after dsDNA spotting. We demonstrate the ability to simultaneously monitor protein binding with the SPR microscope in many 200-microm spots with 1-s time resolution and sensitivity to <1 pg of protein.

Adsorption↗

MutS-mediated detection of DNA mismatches using atomic force microscopy.

We have developed an atomic force microscopy-based method for detecting DNA base-pair mismatches using MutS protein isolated from E. coli. MutS is a biological sensor and a locator of DNA base-pair mismatches. It binds specifically to a mismatched DNA base pair and initiates a process of DNA repair. To test the possibility of visually detecting mismatched base pairs by atomic force microscopy, we prepared DNA templates approximately 500 bp in length consisting of a single or multiple base-pair mismatches. We demonstrate that MutS binding sites on individual DNA molecules were readily detectable by atomic force microscopy and that the observed positions were in good agreement with the predicted sites of base-pair mismatches at a few-nanometer resolution. The technique described here is rapid and sensitive and is expected to be useful in screening mutations and DNA polymorphisms.

Adenosine Triphosphatases↗

Structural studies of apolipoprotein A-I/phosphatidylcholine recombinants by high-field proton NMR, nondenaturing gradient gel electrophoresis, and electron microscopy.

Complexes formed between apolipoprotein A-I (apo A-I) and dimyristoylphosphatidylcholine (DMPC) or egg phosphatidylcholine have been studied by high-field 1H NMR, nondenaturing gradient gel electrophoresis, electron microscopy, and gel filtration chromatography. Emphasis has been placed on an analysis of the particle size distribution within the micellar complexes produced at lipid/protein molar ratios of 40-700. As determined by electron microscopy and gel filtration of DMPC/apo A-I complexes, the size of the discoidal micelles produced appears to increase uniformly with an increasing lipid/protein ratio. By electron microscopy, the diameters of isolated DMPC/apo A-I discoidal micelles range from approximately 89 A at a 40 molar ratio to 205 A at a 700 molar ratio. Analysis of the micellar complexes by 1H NMR shows that concomitant with the increase in size is the progressive downfield shift of the choline N-methyl proton resonance of the complex which is observed from 3.245 to 3.267 ppm over the above molar ratio range. The relationship between chemical shift and micelle size is most simply interpreted as arising from a weighted averaging of two lipid environments--lipid-lipid and lipid-protein. In contrast to the above interpretation of the gel filtration experiments on DMPC/apo A-I complexes, nondenaturing gradient gel electrophoresis analysis of particle size distribution leads to an unexpected observation: as the DMPC/apo A-I ratio increases, discrete complexes of increasing size are formed in an apparently quantized manner.(ABSTRACT TRUNCATED AT 250 WORDS)

Apolipoprotein A-I↗

Interaction of antibodies with Fc receptors in substrate-supported planar membranes measured by total internal reflection fluorescence microscopy.

A procedure for constructing substrate-supported planar membranes using membrane fragments isolated from the macrophage-related cell line J774A.1 is described. Total internal reflection (TIR) fluorescence microscopy is employed to demonstrate that fluorescently labeled Fab fragments of a monoclonal antibody (2.4G2) with specificity for a murine macrophage cell-surface receptor for IgG (moFc gamma RII) bind to the planar model membranes. These measurements show that the planar membranes contain moFc gamma RII and yield a value for the association constant of 2.4G2 Fab fragments with moFc gamma RII equal to (9.6 +/- 0.4) x 10(8) M-1 and indicate that the surface density of reconstituted moFc gamma RII is approximately 50 molecules/microns 2. In addition, TIR fluorescence microscopy is used to investigate the Fc-mediated competition of unlabeled, polyclonal murine IgG with labeled 2.4G2 Fab fragments for moFc gamma RII in the planar membranes. These measurements indicate that the reconstituted moFc gamma RII recognized by 2.4G2 Fab fragments also retains the ability to bind murine IgG Fc regions and yield a value for the association constant of polyclonal murine IgG with moFc gamma RII equal to (1-5) x 10(5) M-1. This work represents one of the first applications of TIR fluorescence microscopy to specific ligand-receptor interactions.

Animals↗

Emission ratiometric imaging of intracellular zinc: design of a benzoxazole fluorescent sensor and its application in two-photon microscopy.

Zinc and calcium are ubiquitous intracellular metals, and while a variety of quantitative probes have been developed for measuring intracellular changes in calcium concentration, the same is not true of zinc. We describe here the design, synthesis, and properties of the benzoxazole-based, ratiometric zinc probe, Zinbo-5. This bright fluorescent reporter has a quantum yield of 0.1 in the zinc-form, exhibits a Kd for Zn2+ in the nanomolar range, and shows significant changes in both excitation and emission maxima upon zinc binding. The utility of this cell permeable probe is demonstrated in fluorescence microscopy emission ratio imaging experiments on mammalian cells. We further show that Zinbo-5 is well suited for two-photon excitation microscopy ratio imaging and can readily reveal changes in intracellular zinc concentration within optical planes of single cells. To the best of our knowledge, this is the first example of two-photon excitation microscopy applied to ratio imaging of zinc. These methods can be applied to real-time emission or excitation ratio imaging studies of zinc physiology in living cells.

Animals↗

Control of localized nanorod formation and patterns of semiconducting CuTCNQ phase I crystals by scanning electrochemical microscopy.

Use of the technique of scanning electrochemical microscopy (SECM) enables the surface of single crystals of 7,7',8,8'-tetracyanoquinodimethane (TCNQ) to be modified in a controlled manner to produce highly dense and micrometer sized regions of semiconducting phase I CuTCNQ nanorod crystals by a nucleation and growth mechanism. This method involves the localized reduction of solid TCNQ to TCNQ- by aqueous phase V(aq)2+ reductant generated at a SECM ultramicroelectrode tip by reduction of V(aq)3+, coupled with the incorporation and reduction of Cu(aq)2+ ions also present in the aqueous electrolyte. SECM parameters can be systematically varied to control the extent of surface modification and the packing density of the CuTCNQ crystals. Scanning electron microscopy (SEM) and atomic force microscopy (AFM) images provide evidence that the TCNQ to CuTCNQ solid-solid transformation is accompanied by a drastic localized crystal volume and morphology change achieved by fragmentation of the TCNQ crystal surface. Patterns of semiconducting CuTCNQ (phase I) nanorod shaped crystals have been characterized by SEM, AFM, and infrared (IR) techniques. A reaction scheme has been proposed for the interaction between the electrogenerated mediator V(aq)2+, Cu(aq)2+, and the TCNQ crystal in the nucleation and growth stages of phase I CuTCNQ formation.

Copper↗

Measurement of drug distribution in vascular tissue using quantitative fluorescence microscopy.

Quantitative tools to assess vascular macromolecular distributions have been limited by low signal-to-noise ratios, reduced spatial resolution, postexperimental motion artifact, and the inability to provide multidimensional drug distribution profiles. Fluorescence microscopy offers the potential of identifying exogenous compounds within intact tissue by reducing autofluorescence, the process by which endogenous compounds emit energy at the same wavelength as fluorescent labels. A new technique combining fluorescence microscopy with digital postprocessing has been developed to address these limitations and is now described in detail. As a demonstration, histologic cross-sections of calf carotid arteries that had been loaded endovascularly with FITC-Dextran (20 kD) ex vivo were imaged at two different locations of the electromagnetic spectrum, one exciting only autofluorescent structures and the other exciting both autofluorescent elements and exogenous fluorescent labels. The former image was used to estimate the autofluorescence in the latter. Subtraction of the estimated autofluorescence resulted in an autofluorescence-corrected image. A standard curve, constructed from arteries that were incubated until equilibrium in different bulk phase concentrations of FITC-Dextran, was used to convert fluorescent intensities to tissue concentrations. This resulted in a concentration map with spatial resolution superior to many of the previous methods used to quantify macromolecular distributions. The transvascular concentration profiles measured by quantitative fluorescence microscopy compared favorably with those generated from the proven en face serial sectioning technique, validating the former. In addition, the fluorescence method demonstrated markedly increased spatial resolution. This new technique may well prove to be a valuable tool for elucidating the mechanisms of macromolecular transport, and for the rational design of drug delivery systems.

Blood Vessels↗

An investigation into the supramolecular structure of ternary gel systems using oscillatory rheometry, microscopy, and low frequency dielectric spectroscopy.

A series of ternary gel systems based on cetostearyl alcohol (CSA) and cetomacrogol 1000 or sodium lauryl sulfate have been studied using oscillatory rheology, differential interference contrast (DIC) microscopy, cryoscanning electron microscopy (cryo-SEM), and low-frequency dielectric analysis in order to elucidate the nature of the lamellar structures formed in relation to composition. The effects of altering the concentration of CSA (0.25% to 8% w/w) for 1% and 2% w/v cetomacrogol 1000 and 0.5% and 1% w/v sodium lauryl sulfate systems have been investigated, with marked increases in the storage and loss moduli seen on increasing the concentration of CSA for both surfactants. DIC microscopy indicated that at low CSA concentrations, needlelike structures were seen which, on increasing the concentration, were observed to congregate into nuclei. At concentrations of 4% CSA and above, neospherical structures were also observed. Cryo-SEM revealed that the needlelike objects were sheet structures ascribed to lamellar gel phases, while the nuclei were folded "rosettes" formed by those sheets, with the spherical structures being ascribed to cetostearyl alcohol. It was also noted that the lamellae were more tightly folded at 8% w/w CSA, which may be associated with the higher rheological moduli for these systems. Low-frequency dielectric analysis was performed over a frequency range of 10(4) Hz to 10(-2) Hz. A decrease in both the dielectric loss and capacitance was observed as the concentration of cetostearyl alcohol was increased. The dielectric data were described in terms of an equivalent circuit model based on a modified Maxwell-Wagner response. A good correlation was found between the fitted and experimental data and the effect of altering the gel composition on specific features of the equivalent circuit are discussed.

Emulsions↗

Characterization of mixed alcohol monolayers adsorbed onto a Au(111) electrode using electro-fluorescence microscopy.

A single-crystal Au(111) electrode modified with an adsorbed layer of 1-octadecanol (C18OH) or oleyl alcohol (OLA) in pure or mixed composition was characterized using electrochemical and in situ fluorescence microscopy. Cyclic voltammetry and differential capacitance measurements revealed a repeatable, potential-induced adsorption/desorption process of the surfactant to/from the electrode surface while charge density and film pressure measurements indicated quasi-ideal mixing of the two adsorbed alcohols. A layer less defective than pure C18OH was created with incorporated OLA. Optical characterization was accomplished using epi-fluorescence microscopy combined with electrochemistry (electro-fluorescence microscopy) through the incorporation of two fluorescent probes into the adsorbed surfactant layer. Since molecular luminescence is quenched by a nearby metal, fluorescence was only observed when the fluorescent dye/alcohol layers were desorbed and therefore separated from the metal surface. When desorbed, the structure of the alcohol layers were similar in character, revealing aggregated features which did not change in morphology over numerous desorption/re-adsorption cycles. We have also used the electro-fluorescence technique to estimate the distance separating the metal and desorbed surfactant and believe that the molecules are displaced from the electrode surface by a distance not more than 40 nm.

Adsorption↗

Nanomagnetic planar magnetic resonance microscopy "lens".

The achievement of three-dimensional atomic resolution magnetic resonance microscopy remains one of the main challenges in the visualization of biological molecules. The prospects for single spin microscopy have come tantalizingly close due to the recent developments in sensitive instrumentation. Despite the single spin detection capability in systems of spatially well-isolated spins, the challenge that remains is the creation of conditions in space where only a single spin is resonant and detected in the presence of other spins in its natural dense spin environment. We present a nanomagnetic planar design where a localized Angstrom-scale point in three-dimensional space is created above the nanostructure with a nonzero minimum of the magnetic field magnitude. The design thereby represents a magnetic resonance microscopy "lens" where potentially only a single spin located in the "focus" spot of the structure is resonant. Despite the presence of other spins in the Angstrom-scale vicinity of the resonant spin, the high gradient magnetic field of the "lens" renders those spins inactive in the detection process.

Magnetic Resonance Imaging↗

Use of immunofluorescence and confocal laser scanning microscopy in identifying rare cases of anti-neutrophil cytoplasmic antibodies (ANCA) showing dual specificities to myeloperoxidase and proteinase3.

Anti-neutrophil cytoplasmic antibodies (ANCA) are the immunodiagnostic markers for idiopathic necrotizing crescentic glomerulonephritis affecting mainly medium to small sized blood vessels. The diagnosis of ANCA associated vasculitis (AAV) is mainly based on clinical and histopathological characteristics along with the serological evidence. Immunofluorescence microscopy (IIF) is considered as the "gold standard" for ANCA detection, and ANCA showing two major patterns ie, cytoplasmic (c-ANCA) and perinuclear (p-ANCA) react with different antigenic targets of neutrophils like Proteinase3 (PR3) and Myeloperoxidase (MPO). A third unusual and rare immunofluorescence pattern called as "X- ANCA" or atypical ANCA is also sometimes seen. The difficulty in identification of ANCA immunofluorescence patterns is mainly seen due to the rare dual patterns seen in the same sera and also the additional nuclear immunofluorescence seen due to presence of anti-nuclear antibodies. ANCA testing by immunofluorescence and Confocal Laser scanning microscopy, as well as by specific ELISAs for detection of anti-PR3 and anti-MPO antibodies have helped in improving the diagnosis. Patients having dual specificities to MPO and PR3 in a patient is a rare finding. Among 425 clinically and histopathologically proven cases of AAV, eight patients (1.9%) had dual specificities, of which five patients showed mixed immunofluorescence pattern and 3 patients showed X-ANCA pattern which was confirmed by both immunofluorescence and Confocal Laser scanning microscopy and the dual specificities to MPO and PR3 were detected by individual ELISAs.

Adolescent↗

Melanoma or pigmented basal cell carcinoma: a clinical-pathologic correlation with dermoscopy, in vivo confocal scanning laser microscopy, and routine histology.

BACKGROUND/PURPOSE: New techniques are being explored for improving diagnostic accuracy of pigmented skin lesions. Confocal scanning laser microscopy (CSLM) may represent such a novel technique. The purpose of this report was to demonstrate the potential application of CSLM as an aid in the diagnosis of a pigmented skin lesion that is clinically suspicious for melanoma. METHODS: An irregular pigmented lesion was examined clinically and dermoscopically. The lesion was imaged by CSLM and subsequently excised for histologic examination. Findings from CSLM were correlated with features observed on the dermoscopic and histologic examination. RESULTS: Confocal scanning laser microscopy (CSLM) allowed for the non-invasive visualization of the histologic features of superficial pigmented BCC, including buds and "islands" of tumor cells at the dermoepidermal junction and melanin-laden macrophages. Conventional histology confirmed the diagnosis of pigmented BCC. CONCLUSION: Confocal scanning laser microscopy (CSLM) may serve as an aid in the non-invasive diagnosis of pigmented skin lesions clinically suspicious for melanoma.

Aged↗

Cryo-electron microscopy of viruses.

Thin vitrified layers of unfixed, unstained and unsupported virus suspensions can be prepared for observation by cryo-electron microscopy in easily controlled conditions. The viral particles appear free from the kind of damage caused by dehydration, freezing or adsorption to a support that is encountered in preparing biological samples for conventional electron microscopy. Cryo-electron microscopy of vitrified specimens offers possibilities for high resolution observations that compare favourably with any other electron microscopical method.

Adenoviruses, Human↗

Determination of surface topography of biological specimens at high resolution by scanning tunnelling microscopy.

Although techniques are available for the determination of the three-dimensional structure of biological specimens, for example scanning electron microscopy, they all have some serious drawback, such as low resolution, the requirement for crystals or for the sample to be analysed in a high vacuum. In an attempt to develop a technique for high-resolution three-dimensional structure analysis of non-crystalline biological material, we have tested the applicability of scanning tunnelling microscopy (STM), a method that has been used successfully in the analysis of metal and semiconductor surface structures. We report here that scanning tunnelling electron microscopy can be used to determine the surface topography of biological specimens at atmospheric pressure and room temperature, giving a vertical resolution of the order of 1 A. Our results show that quantum mechanical tunnelling of electrons through biological material is possible provided that the specimen is deposited on a conducting surface.

Atmospheric Pressure↗

Confocal microscopy visualization of antifolate uptake by the reduced folate carrier in human leukaemic cells.

Confocal microscopy was used to visualize the intracellular uptake of the fluorescent methotrexate analogue, fluorescein-MTX (F-MTX), in human leukaemic cell lines and leukaemic blasts. Cytosolic labelling of wild-type K562 human erythroleukaemia cells was detected during 3-60 min incubations with F-MTX (1 microM) and was completely inhibited by co-exposure to either methotrexate or the thymidylate synthase inhibitor, ZD1694. There was no significant intracellular F-MTX accumulation over this period in a K562 subline (K500E) with a documented defect (approximately 10% of wild type) in membrane transport by the reduced folate carrier (RFC). F-MTX uptake was re-established in K500E cells transfected with a cDNA to human RFC, establishing a role for RFC in the cellular uptake of this compound. High levels of intracellular labelling were detected in all cell lines after prolonged (24 h) F-MTX incubations, however F-MTX accumulation at this time was not inhibited by ZD1694. F-MTX uptake by RFC was also detected in leukaemic blasts from children with acute lymphoblastic leukaemia and could be blocked with ZD1694. In leukaemic blasts with a documented defect in MTX uptake, F-MTX accumulation was abolished in almost all the cells. These results display the power of confocal microscopy for directly visualizing RFC-mediated anti-folate uptake. Over short intervals, F-MTX uptake is mediated by RFC, however, RFC-independent processes predominate during long drug exposures. Direct assay by confocal microscopy may be better suited than other indirect methods (i.e. flow cytometry) for detecting low levels of RFC transport in leukaemic blasts from patients undergoing chemotherapy with methotrexate.

Biological Transport↗

Lamellar separation in the human lens: the case for fibre folds. A combined in vivo and electron microscopy study.

Lamellar separation is seen as parallel lines in the lens cortex. It has been the subject of a joint study between Oxford and Amsterdam. The condition was studied in vivo by macro photography and in vitro by scanning electron microscopy. The lines are seen to run concentric with the lens equator, crossing the lens fibres at right angles. The lines are commonly limited by a spoke cataract, a water cleft, or a lens suture. The line may continue beyond these features with a change in direction. The lines may branch and rejoin. The lines extend in depth into the lens, polarised light showing that the lines are due to reflection. The name 'lamellar separation' implied that the appearance is due to separation between the lens lamellae. Lamellar separation is now shown by electron microscopy to be due to folds crossing the lens fibres. The clinical study showed the lines occurring with spoke cataract and the electron microscopy showed the association with the novel finding of peripheral breaks in the fibres. A new name 'Fibre Folds' is proposed.

Aged↗

Electroperturbation of human stratum corneum fine structure by high voltage pulses: a freeze-fracture electron microscopy and differential thermal analysis study.

Application of high voltage pulses (HVP) to the skin has been shown to promote the transdermal drug delivery by a mechanism involving skin electroporation. The aim of this study was to detect potential changes in lipid phase and ultrastructure induced in human stratum corneum by various HVP protocols, using differential thermal analysis and freeze-fracture electron microscopy. Due to the time involved between the moment the electric field is switched off and the analysis, only "secondary" phenomena rather than primary events could be observed. A decrease in enthalpies for the phase transitions observed at 70 degrees C and 85 degrees C was detected by differential thermal analysis after HVP treatment. No changes in transition temperature could be seen. The freeze-fracture electron microscopy study revealed a dramatic perturbation of the lamellar ordering of the intercellular lipid after application of HVP. Most of the planes displayed rough surfaces. The lipid lamellae exhibited rounded off steps or a vanished stepwise order. There was no evidence for perturbation of the corneocytes content. In conclusion, the freeze-fracture electron microscopy and differential thermal analysis studies suggest that HVP application induces a general perturbation of the stratum corneum lipid ultrastructure.

Electric Stimulation↗