At least 1,729 records · Page 96Linked to original sources

Interfragmentary compression across a simulated scaphoid fracture--analysis of 3 screws.

PURPOSE: To measure the interfragmentary compression generated across a simulated fracture in cadaveric scaphoids by 3 different headless compression screws. METHODS: A transverse osteotomy was made through the waist of each scaphoid and a load cell to measure compression was interposed between the fragments, which were then fixed internally retrograde with either an Acutrak Standard (n = 10), Acutrak Mini (n = 12), or Bold (n = 10) screw. The surgeon was blinded to the measured compression, which was recorded during screw insertion and for the following 5 minutes. As a measure of scaphoid bone quality the modulus of elasticity of the trabecular bone of each specimen was then calculated from uniaxial compression tests. RESULTS: The mean interfragmentary compression generated by the Acutrak Standard screw was significantly greater and more consistent than the Bold screw or the Acutrak Mini screw. The compression achieved by the Acutrak Standard screw was also more consistent than that obtained by either the Bold or the Acutrak Mini screws as reflected by the lower standard deviation. The mean modulus of elasticity of the scaphoid trabecular bone was similar for each screw group. CONCLUSIONS: The interfragmentary compression generated by the Acutrak Standard screw was significantly greater and more consistent than that generated by either the Bold or Acutrak Mini screws. The compression generated by the Acutrak Standard and Mini screws was significantly better sustained over time than that generated by the Bold screw; however, these differences were small and may not be clinically important. The optimal compression required to promote scaphoid fracture union remains unknown and clinical trials are needed to further evaluate the outcome from using these devices.

Adult↗

Self-compression plates for orbital rim fractures.

The development and principles of self-compression plating, as well as a series of patients treated with this technique, are described. The use of such plates has specific advantages over other techniques for disorders encountered by the oculoplastic surgeon. The indications for plating were displaced trimalar fracture, displaced trimalar fracture with orbital rim fragment, and comminuted orbital rim fracture. Results were good; no complications have been observed to date. Comparison of compression plating to other methods for repair of orbital fractures is made. Self-compression plating with Vitallium plates is an effective modality for the treatment of a broad spectrum of patients with orbital rim fractures.

Adolescent↗

Differentiation of spinal damage through compression mechanism.

In the years 1965 to 1986, 986 patients with spine fractures caused by compression were treated at the Rehabilitation Clinic. This communication presents an analysis of those patients, taking into account the significant differences between typical compression fractures and explosion fractures, the latter are, as a rule, complicated by considerable or complete spinal cord damage. The author has pointed to the differences in the indication for surgery, different prognosis and significantly different results of treatment. The author is of the opinion that, due to those differences, the two kinds of spinal fractures should be considered separately with regard to the analysis of the mechanism of injury, the prognosis and the assessment of the results of treatment.

Adult↗

Sliding of the compression hip screw in femoral neck fractures.

Backing out of the compression screw in the sliding screw-plate hip osteosynthesis was analyzed in a series of 71 hips with medial femoral neck fractures during an observation period of 12-42 months, with a median of 26 months. In addition to the compression screw device, a parallel cranial lag screw was used. A postoperative primary diastasis in the fracture space of 1-5 mm in 11 cases did not predispose to major sliding of the screws or to healing problems. Thirteen of 27 fractures with late screw telescoping of 4 mm or more showed healing disturbances, 11 late segmental collapses, and 2 nonunions, compared with 7 disturbances, 6 late segmental collapses, and 1 nonunion among 39 cases with screw gliding of 3 mm or less. The difference was significant (p less than 0.05, Mann-Whitney). Five early mechanical failures were excluded from this analysis.

Adolescent↗

High friction compression in the treatment of complicated fractures of the lower extremity.

Charnley's compression clamps have hastened the union of cancellous bones but not much success has been obtained in the slender shafts of cortical bones. The principles of biophysics show that a fracture site under compression acts as a hinge joint. If friction is increased in such "joints" along indicated axes, immobility of the fracture fragments can be obtained and lead to bone union. We have developed a modified device based on Charnley's compression clamps to create high friction compression. We successfully applied it in the treatment of eight fractures of the shafts of the femur or tibia which would not unite because of infection, soft tissue interposition or gross incongruity of fragments. The mechanical aspects of creating friction with the device are discussed.

Adult↗

Compression-staple fixation for fractures, non-unions, and delayed unions of the carpal scaphoid.

We used the Richards scaphoid compression staple for operative fixation in a total of twenty-five patients who had a fracture of the carpal scaphoid: sixteen whom we reported on previously and nine whom we are reporting on for the first time here. In the current series, we extended the application of the method to fresh, unstable fractures (two patients) and treated an additional seven patients who had a non-union or delayed union. The procedure was simple, and no operative complications were encountered. Both patients who had a fresh fracture had a satisfactory result. Of the other twenty-three patients, only two had a result that was not satisfactory. One patient had a persistent non-union. Three patients had doubtful radiographic evidence of a persistent non-union; however, all three had a good result clinically, and only one had moderate loss of function. Although the over-all results were good, there was some worsening of the clinical results on long-term follow-up compared with those that we reported earlier. This deterioration probably was due to secondary degenerative changes in the articular surfaces.

Adult↗

Acute closed humeral shaft fractures treated with dynamic compression plate.

BACKGROUND: To define the efficacy of dynamic compression plates (DCPs) for the treatment of closed humeral shaft fractures. METHODS: A total of 165 patients with closed humeral shaft fractures were studied retrospectively. There were 120 patients who underwent open reduction and internal fixation with DCPs and no bone grafting (BG). Forty-five patients received the same procedures with BG. The mean follow-up period was 93 months. RESULTS: In the DCP without BG group, the average blood loss was 350 ml, operation time was 105 minutes, hospital stay was 8.5 days and fracture union time was 13.5 weeks. In the DCP with BG group, the average blood loss was 525 ml, operation time was 115 minutes, hospital stay was 7.9 days and fracture union time was 9.2 weeks. CONCLUSIONS: In our experience, DCPs are effective for surgical fixation of humeral shaft fractures. Prophylactic BG is recommended for cases with more comminution.

Adolescent↗

Humeral shaft fractures treated by dynamic compression plates, Ender nails and interlocking nails.

Between January 1991 and December 2002, we treated 92 acute, displaced, closed humeral shaft fractures (AO classification type A). We used three fixation methods: dynamic compression plates (DCP) in 36 patients, Ender nails (EN) in 32 patients and interlocking nails (ILN) in 24 patients. The patients were followed for a minimum of 24 months. At one year, all fractures except two (one DCP/one ILN) had united. Patients treated with EN had shorter mean operation time, 51 (35-110) min; less mean blood loss, 70 (30-170) ml and shorter mean hospital stay, 5.8 (3-12) days. There were three iatrogenic radial nerve palsies: two in the DCP group and one in the ILN group. There was one wound infection. There were three cases with impingement of the shoulder but range of motion was restored after nail removal. For patients with multiple trauma or high operative risk, EN fixation served as a safer and faster procedure. ILN fixation offered a stable fixation via a smaller incision but more fracture comminution might happen.

Adult↗

Effect of diameter of the drill hole on torque of screw insertion and pushout strength for headless tapered compression screws in simulated fractures of the lateral condyle of the equine third metacarpal bone.

OBJECTIVE: To compare variables for screw insertion, pushout strength, and failure modes for a headless tapered compression screw inserted in standard and oversize holes in a simulated lateral condylar fracture model. SAMPLE POPULATION: 6 pairs of third metacarpal bones from horse cadavers. PROCEDURE: Simulated lateral condylar fractures were created, reduced, and stabilized with a headless tapered compression screw by use of a standard or oversize hole. Torque, work, and time for drilling, tapping, and screw insertion were measured during site preparation and screw implantation. Axial load and displacement were measured during screw pushout. Effects of drill hole size on variables for screw insertion and screw pushout were assessed by use of Wilcoxon tests. RESULTS: Drill time was 59% greater for oversize holes than for standard holes. Variables for tapping (mean maximum torque, total work, positive work, and time) were 42%, 70%, 73%, and 58% less, respectively, for oversize holes, compared with standard holes. Variables for screw pushout testing (mean yield load, failure load, failure displacement, and failure energy) were 40%, 40%, 47%, and 71% less, respectively, for oversize holes, compared with standard holes. Screws could not be completely inserted in 1 standard and 2 oversize holes. CONCLUSIONS AND CLINICAL RELEVANCE: Enlarging the diameter of the drill hole facilitated tapping but decreased overall holding strength of screws. Therefore, holes with a standard diameter are recommended for implantation of variable pitch screws whenever possible. During implantation, care should be taken to ensure that screw threads follow tapped bone threads.

Animals↗

[Experiences and results with the locked compression plate for 603 fractures of the distal radius].

Between January 1999 and December 2003 we have treated 603 patients with a fracture of the distal radius without concomitant injuries with the Synthes locked compression plate. The locked compression plate, the concept of the postoperative treatment, and our results are presented. In most cases we have used the palmar plate. We see an indication for the palmar plate in the A2 and A3, B2 and B3 and in all C fractures. It is also practicable for fractures with dorsal comminutions. Because of its permanent retention due to the subchondral fixation of the splints (internal fixation), this new plate makes early mobilization possible. The palmar approach with its good soft-tissue coverage not only reduces the risk of infections but also offers the possibility of not having to remove the plate. A cancellous bone graft is only seldom necessary.

Adolescent↗

A comparison of the effect of open intramedullary nailing and compression-plate fixation on fracture-site blood flow and fracture union.

UNLABELLED: We compared the effects of compression-plating and open intramedullary nailing after reaming on the vascular supply to a standard fracture site, on the rate of fracture union, and on the biomechanical quality of bone after union, and on the biomechanical quality of bone after union in dogs. The proper location of a compression plate in relation to the periosteum also was investigated. Bone blood flow reached higher levels and remained elevated longer in fractures that were fixed with a rod than in those fixed with a plate. Rod-fixed fractures healed by periosteal callus, whereas plate-fixed fractures healed by endosteal callus. The fracture gained mechanical strength more slowly in the rod-fixed group than in the plate-fixed group. Subperiosteal or extraperiosteal placement of a plate revealed similar effects on bone-healing. CLINICAL RELEVANCE: Decisions to use intramedullary rods or compression plates for internal fixation of fractures should be based on knowledge of the biological effects of these procedures on blood flow at the fracture site and on the mechanical strength of the healing fracture. This study defines in quantitative terms the advantages and disadvantages of intramedullary rods compared with compression plates in the internal fixation of fractures.

Animals↗

Biomechanical evaluation of the percutaneous compression plating system for hip fractures.

OBJECTIVE: To investigate the biomechanical properties of the percutaneous compression plating system for intertrochanteric hip fractures. DESIGN: A biomechanical laboratory investigation on human cadaveric upper femora was conducted. SETTING: Biomechanical laboratory. PATIENTS: Sixteen femora from cadavers of patients aged 60 to 85 years. INTERVENTION: An intertrochanteric fracture was performed along the intertrochanteric line and fixed with the percutaneous compression plating system. MAIN OUTCOME MEASUREMENTS: Postfixation and postcycling bending and torsional stiffnesses, and load to failure at 0, 7, and 25 degrees of adduction. RESULT: The normalized postfixation bending and torsional stiffnesses in the neutral position were 65% and 59%, respectively, and higher with adduction. After percutaneous compression plating fixation, bending stiffness increased to 72% following cyclic loading ( < 0.05). It was comparable to that of similar fixation constructs in the literature, whereas the torsional stiffness was somewhat higher. The mode of failure was distal femoral neck sagging, indicating good femoral head fixation. No varus displacement and cutouts were observed. CONCLUSIONS: Our biomechanical data indicate that the percutaneous compression plating provides adequate bending stiffness and torsional stability. With sliding capability this fixation leads to controlled fracture impaction, which is further enhanced by cyclic loading.

Aged↗