Efficacy of lower-energy biphasic shocks for transthoracic defibrillation: a follow-up clinical study.

OBJECTIVE: This clinical study prospectively evaluated the first-shock defibrillation efficacy of 150-joule impedance-compensated, 200-microF biphasic truncated exponential (BTE) shocks in patients with electrically-induced ventricular fibrillation (VF), and compared it with a historical control group treated with 200-J monophasic damped sine (MDS) shocks. METHODS: Ventricular tachyarrhythmias were induced in patients undergoing electrophysiologic (EP) testing for ventricular arrhythmias or testing of an implantable cardioverter-defibrillator (ICD). A 150-J shock was delivered as the primary therapy to terminate induced arrhythmias in the EP group, and as a "rescue" shock when a single ICD shock failed to terminate the arrhythmias in the ICD group. RESULTS: Ninety-six patients received study shocks. The preshock rhythm was classified as VF in 77 patients and as ventricular tachycardia (VT) in 19 patients. First-shock success rates for VF and VT were 75 out of 77 (97.4%) and 19 out of 19 (100%) for the 150-J BTE compared with the historical control rates of 61 out of 68 (89.7%) and 29 out of 31 (94%) for 200-J MDS. The first-shock success rate for VF treated with 150-J BTE was technically equivalent to that of 200-J MDS (p=0.001). The transthoracic impedance did not vary between groups, yet the peak current delivered by the 150-J BTE shock was about 50% lower. CONCLUSIONS: This study demonstrated that 150-J shocks of this impedance-compensated, 200-microF BTE waveform provided very high efficacy for defibrillation of short duration, electrically-induced VF. These lower-energy biphasic shocks had a success rate equivalent to that of 200-J MDS shocks, and they provided this efficacy while exposing patients to much less current than the monophasic shocks.

Adult↗

Skill acquisition and retention in automated external defibrillator (AED) use and CPR by lay responders: a prospective study.

This prospective study evaluated the acquisition and retention of skills in cardio-pulmonary resuscitation (CPR) and the use of the automated external defibrillator (AED) by lay volunteers involved in the Department of Health, England National Defibrillator Programme. One hundred and twelve trainees were tested immediately before and after and initial 4-h class; 76 were similarly reassessed at refresher training 6 months later. A standardised test scenario that required assessment of the casualty, CPR and the use of on AED was evaluated using recording manikin data and video recordings. Before training only 44% of subjects delivered a shock. Afterwards, all did so and the average delay to first shock was reduced by 57 s. All trainees placed the defibrillator electrodes in an "acceptable" position after training, but very few did so in the recommended "ideal" position. After refresher training 80% of subjects used the correct sequence for CPR and shock delivery, yet a third failed to perform adequate safety checks before all shocks. The trainees self-assessed AED competence score was 86 (scale 0-100) after the initial class and their confidence that they would act in a real emergency was rated at a similar level. Initial training improved performance of all CPR skills, although all except compression rate had deteriorated after 6 months. The proportion of subjects able to correctly perform most CPR skill was higher following refresher training that after the initial class. Although this course was judged to be effective in teaching delivery of counter-shocks, the need was identified for more emphasis on positioning of electrodes, pre-shock safety checks, airway opening, ventilation volume, checking for signs of a circulation, hand positioning, and depth and rate of chest compressions.

Adult↗

Adherence to guidelines when positioning the defibrillation electrodes.

BACKGROUND: Placement of the defibrillation electrodes affects the transmyocardial current and thus the success of a defibrillation attempt. In the international guidelines 2000, the placement of the apical electrode was changed more laterally to the mid-axillary line. Finnish national guidelines, based on the international guidelines, were published in 2002. OBJECTIVES: The purpose of this study was to determine to what extent health care professionals adhere to the new guidelines when positioning the electrodes. METHODS: Professionals were recruited from emergency medical services, university hospitals and primary care. Not revealing the purpose of the test, participants were asked to place self-adhesive electrodes on a manikin as they would do in the resuscitation situation and to answer a questionnaire about resuscitation training and familiarity with the guidelines. The distance of electrodes from the recommended position was measured in horizontal and vertical planes. RESULTS: One-hundred and thirty six professionals participated in the study, and only 25.4% (95% CI 18.5-32.9) of them placed both electrodes within 5 cm from the recommended position. The majority of the participants placed the apical electrode too anteriorly. Of the participants, 36.0% were not aware of the new guidelines. Awareness of the guidelines did not increase the accuracy in electrode placement. CONCLUSIONS: The publication of the national evidence based resuscitation guidelines did not seem to have influenced the practice of placement of the defibrillation electrodes to any major extent. The correct placement of the electrodes needs be emphasized more in the resuscitation training.

Attitude of Health Personnel↗

An assessment of public attitudes toward automated external defibrillators.

OBJECTIVE: We assessed the familiarity of the general public with automated external defibrillators (AEDs) and their willingness to use them. METHODS: Shoppers were asked to complete a survey in an AED-equipped suburban shopping mall. RESULTS: 359 surveys were analyzed. Of the participants, 11% were healthcare professionals, 51% had training in CPR or first aid, and 44% had no medical training. Sixty percent were able to define defibrillator adequately. Seventy-one percent stated they would be likely to use an AED to resuscitate a stranger. The most common concerns were fear of using the machine incorrectly (57%) and fear of legal liability (38%). After being told of liability protection from the federal Cardiac Arrest Survival Act, 84% stated they would be likely to use the AED. This increased further to 91% if the participants were given an opportunity to receive training. CONCLUSION: Although a substantial number of people in this setting were willing to use an AED, education regarding legal liability and proper use of the machines increased the reported likelihood of use. Further public education may be necessary to provide optimally effective public access defibrillation programs.

Adult↗

Teaching public access defibrillation to lay volunteers--a professional health care provider is not a more effective instructor than a trained lay person.

BACKGROUND: Survival improves in witnessed out-of-hospital cardiac arrest if the victim receives bystander-initiated cardiopulmonary resuscitation and rapid defibrillation (BLS/AED). The European Resuscitation Council has a simple programme to teach these life-saving skills that require no previous experience of automated external defibrillators (AEDs). To be able to implement the use of AEDs widely, many instructors are needed, and therefore, lay persons may also be used as trainers. The purpose of this randomized study was to compare lay volunteers trained by a lay person with those trained by a health care professional using the Objective Structured Clinical Examination (OSCE). METHODS: Eight instructors, including four lay persons and four health care professionals, were given a basic course and an instructor course in CPR-D by the same instructor. All newly trained instructors trained 38 lay volunteers (19 pairs) who had no previous training in the use of a defibrillator. The lay volunteers performed the OSCE 2-3 weeks after the course. The OSCE comprised two scenarios with a manikin: the first, a patient in cardiac arrest with ventricular fibrillation, and the second, an imminent cardiac arrest with asystole as the initial rhythm. The same OSCE was performed by a group of lay first aiders practicing every 2 weeks who served as the control group. RESULTS: No statistical difference was present between the two groups of lay volunteers in the OSCE. All were able to use the AED and follow instructions. They identified patients with ventricular fibrillation and cardiac arrest, but had difficulties identifying cases with imminent cardiac arrest. The control group of trained first aiders performed significantly more effectively than the newly trained lay persons. CONCLUSIONS: No significant benefit exists in the trainer being a health care professional, but thorough training and subsequent rehearsing of the skills learned are crucial.

Cardiopulmonary Resuscitation↗

Myocardial ischaemic preconditioning in the pig has no effect on the ventricular fibrillation and defibrillation thresholds.

INTRODUCTION: The effects of myocardial ischaemia preconditioning in pigs on the vulnerability to ventricular fibrillation during subsequent ischaemic events are controversial. This study examined the time course of changes in ventricular fibrillation (VFT) and defibrillation (DFT) thresholds during transient myocardial ischaemia after a 45 min preconditioning period. METHODS AND RESULTS: In five open-chest pigs, VFT was measured after 3 min of regional myocardial ischaemia, at time 0, 2, 15, 30, 60 and 90 min (Control group). In seven other pigs (Test group), VFT was measured before (time 0) and 2, 15, 30, 60 and 90 min after ischaemic preconditioning by three consecutive 5 min periods of regional coronary occlusion, followed by 10 min of reperfusion. DFT was measured by increasing the stored energy systematically until successful defibrillation. Ischaemic preconditioning caused no significant change in the effective refractory period (ERP), VFT or DFT over the 90 min of the experiments. In the Control group, ERP remained stable for 30 min, though was significantly lower at 90 min (178 +/- 28 ms) than at baseline (204 +/- 32 ms, P = 0.007). VFT and DFT remained unchanged throughout the experiments, and no difference was observed in ERP, VFT and DFT between the two groups at any time during the experiment. CONCLUSION: No changes were observed in the refractory duration, ventricular vulnerability or defibrillation energy requirements up to 90 min after ventricular ischaemic preconditioning in the pig.

Animals↗

Echocardiographic parameters for predicting maintenance of sinus rhythm after internal atrial defibrillation.

Chronic atrial fibrillation (AF), which is refractory to external electrical direct current shock and/or pharmacologic cardioversion, may be successfully cardioverted using internal atrial defibrillation. To avoid unnecessary procedures, it is important to be able to predict which patients will revert to AF. Thirty-eight patients with chronic AF underwent successful internal atrial defibrillation and were followed for 6 months after restoration of sinus rhythm. Left atrial (LA) diameter, left ventricular ejection fraction, maximum LA appendage area, and peak emptying velocities of the LA appendage were analyzed to determine which of these factors were associated with recurrence of AF. Forty-nine percent of patients had a recurrence of AF within 6 months following internal atrial defibrillation. The preprocedural ejection fraction (mean +/- SD 59 + 14% vs 57 + 13%, p = 0.63), LA diameter (4.2 +/- 0.6 cm vs 4.5 +/- 0.6 cm, p = 0.16), and LA appendage area (5.0 +/- 1.5 cm2 vs 5.8 +/- 1.5 cm2, p = 0.13) did not differ significantly between patients who maintained sinus rhythm and those who had recurrence of AF. Peak emptying velocities of the LA appendage before cardioversion were significantly lower in patients with recurrence of AF compared with patients who maintained sinus rhythm (0.26 +/- 0.1 m/s vs 0.49 +/- 0.17 m/s, p = 0.001). A peak emptying velocity <0.36 had a sensitivity of 82% and a specificity of 83% for predicting recurrence of AF.

Aged↗

The treatment of malignant ventricular arrhythmias with combined endocardial resection and implantation of the automatic defibrillator: preliminary report.

Fourteen patients with refractory ventricular tachyarrhythmias were treated with combined endocardial resection and implantation of the automatic defibrillator. There were 11 men and 3 women with a mean age of 53 years (range, 41 to 58 years). All patients had coronary artery disease; the mean ejection fraction was 26%, and the mean number of cardiac arrests was 2.6. Programmed electrical stimulation induced sustained ventricular tachycardia in 13 patients and nonsustained ventricular tachycardia in 1. Operative endocardial mapping in the 13 patients with sustained ventricular tachycardia demonstrated a septal focus of early activation in 9 patients and a nonseptal site in 4. Following resection, sustained ventricular tachycardia could not be reinduced. There was 1 operative death. Programmed electrical stimulation performed one month after operation induced ventricular tachycardia in 5 patients, but tachycardia could not be induced in the other 8 survivors. The longest follow-up was 32 months; the average was 17 months. There were 2 late deaths. One patient died of myocardial infarction and 1 of pulmonary edema following a routine cholecystectomy. In another patient, late ventricular tachycardia developed but was automatically terminated by the implanted defibrillator. These results suggest that endocardial resection combined with implantation of the automatic defibrillator may offer the greatest protection yet available to patients with malignant ventricular tachyarrhythmias.

Adult↗

Transdiaphragmatic implantation of the automatic implantable cardioverter defibrillator.

A new surgical approach for implantation of the automatic implantable cardioverter defibrillator without thoracotomy was used in 12 patients, aged 46 to 72 years. Preimplantation arrhythmia was ventricular tachycardia in 7 patients and ventricular fibrillation in 5 patients. The mean ejection fraction was 19%. Six patients were at high risk for general anesthesia for a variety of medical problems, and 2 patients had had a previous cardiac operation. Epidural anesthesia was used in 8 patients without intubation. The surgical approach used a longitudinal epigastric extraperitoneal incision with access to the heart through an incision made in the central tendon of the diaphragm. Two patches and two epicardial sensing leads were placed in all patients. All patients but one could be defibrillated with 20 J or less. There was no operative mortality and minimal morbidity. There were two late deaths due to heart failure. Thus, the transdiaphragmatic approach provides an excellent exposure for automatic implantable cardioverter defibrillator implantation, avoids general anesthesia and thoracotomy, and can be used after a previous cardiac operation.

Aged↗

Use of self-adhesive external defibrillator pads for complex cardiac surgical procedures.

We describe a useful technique for the management of life-threatening arrhythmias that occur during complex or reoperative cardiac surgical procedures when internal defibrillation cannot be achieved. Two self-adhesive external pads are attached to the patient before draping to enable the delivery of current for defibrillation or cardioversion without the need for removal of adhesive surgical drapes and the cumbersome use of external defibrillator paddles.

Arrhythmias, Cardiac↗

Trans-chest ventricular defibrillation of heavy subjects using trapezoidal current waveforms.

Effectiveness of four truncated exponential waveform defibrillators for transchest ventricular defibrillation was evaluated in 27 human-sized animals. With all waveforms, effectiveness was virtually 100% for small subjects, but decreased as body weight increased. These data confirm the electrical dose concept for ventricular defibrillation and demonstrate that the truncated exponential waveform is effective only when adequate current is delivered through the subject's chest.

Animals↗

Ventricular fibrillation and transient arrhythmias after defibrillation in patients with acute myocardial infarction.

Ventricular fibrillation (VF) and transient arrhythmias after defibrillation were analyzed from the recordings of 28 patients containing at least one episode of ventricular fibrillation. An R-on-T extrasystole initiated VF in 60% of the episodes. Other initiating factors were a late premature beat (24%), stable ventricular tachycardia (VT) (7%), accelerating idioventricular rhythm (5%) and cardioversion of VT (5%) with a sinusoidal waveform. After the initiating beat, in most cases, evidence was found of a transient ventricular tachycardia which then deteriorated into VF. With a stable VT this may occur after a long time; in the case of apolymorphic VT (with changing amplitude) it generally occurred within 30 s. The main transient arrhythmias generated by circulatory arrest during VF and by the defibrillation shock were: total arrest, total AV-block and/or bradycardia. The combination of a longer duration of VF and a high energy level generally resulted in an increase in the duration of these arrhythmias (P less than 0.01, N = 30). Comparison of episodes of VT and VF recorded in a single patient also shows that arrhythmias are more unfavourable and of longer duration after VF than after VT. These data emphasize fast defibrillation, initially with stored energy levels less than 250J.

Adult↗

Increased defibrillation threshold due to ventricular fibrillation duration. Potential mechanisms.

The duration of ventricular fibrillation (VF) that precedes a high energy shock has been recognized as a critical determinant of defibrillation outcome. Factors such as metabolic acidosis or alkalosis do not affect outcome. The authors hypothesized that release of myocardial adenosine during VF could potentially mediate the time-dependent effects of VF duration on defibrillation. Defibrillation threshold (DFT) was therefore determined in dogs during concurrent infusion of adenosine and dipyridamole (a nucleoside transport blocker). Transthoracic DFT increased by approximately 50%, whereas transmyocardial DFT increased by approximately 100% in a separate group of dogs. These effects of adenosine on DFT were abolished when the dogs were autonomically denervated, suggesting that the deleterious effects of adenosine on DFT are due to its antiadrenergic mechanism of action. These data indicate that adenosine release during VF can markedly increase DFT. Since adenosine myocardial release during VF is time dependent, it is likely that adenosine plays a significant role in mediating the increase in threshold that is dependent on the duration of VF.

Adenosine↗

Relation between ventricular fibrillation voltage and probability of defibrillation shocks. Analysis using Hilbert transforms.

We used Hilbert transforms to re-evaluate the previously reported correlation between defibrillation shock outcome and absolute ventricular fibrillation voltage (AVFV). Previously in the literature, single values of AVFV acquired just prior to shock delivery were used to show a correlation between AVFV and shock outcome. In subsequent studies, a modified analysis procedure was used to show a correlation between shock outcome and moving average of AVFV. The use of single values of AVFV makes the AVFV sensitive to the local phase of the electrocardiographic (ECG) waveform, whereas moving averages are weighted by previous values of the ECG. The envelope is independent of the phase of the ECG and is not weighted by previous values of ECG as is the moving average. We explored, therefore, whether the AVFV computed from the envelopes of the ECG showed a stronger correlation with shock outcome than single values and moving averages of the AVFV. We estimated envelopes using the Hilbert transform. Orthogonal ECGs (sagittal, X; transverse, Y; and longitudinal, Z) were recorded from 11 dogs during 10 seconds of electrically induced ventricular fibrillation followed by a defibrillation shock with 50% probability of success. We used transvenous (right ventricular apex to subcutaneous patch) leads to deliver defibrillation shocks. Results from 236 successful and 249 unsuccessful trials showed, in contrast with the previously reported correlation, that moving average of AVFV was not higher for successful trials. In the Z direction, unsuccessful trials had higher voltage than successful trials (P < .05). Comparison of envelope voltages between successful and unsuccessful trials did not show any consistent and statistically significant differences. Although there were some methodological differences between ours and the previously reported studies, they are unlikely to have caused the discrepant observations. Our results suggest, therefore, that the absolute voltage of ECG during ventricular fibrillation is not robustly correlated with shock outcome.

Animals↗

Can shocks timed to action potentials in low-gradient regions improve both internal and out-of-hospital defibrillation?

During the first minute of fibrillation, circulating wavefronts excite new fibrillation action potentials almost immediately following termination of the preceding action potential. The extension of refractoriness hypothesis states that a successful defibrillating shock must produce a uniform postshock refractoriness of a specific optimal duration throughout the ventricle, which blocks these wavefronts and terminates fibrillation. We hypothesized that, if shocks are appropriately timed early in the fibrillation action potential in low-voltage-gradient regions, postshock refractoriness will already be long and the shock need not be strong enough to further extend it. This will result in a lower defibrillation threshold (DFT). This hypothesis was tested in the isolated rabbit heart model. Shocks were synchronized to monophasic action potentials recorded from a low-intensity region. An up/down protocol was used. I50 for early shocks was 17% lower than that for late shocks (31% decrease in E50). Standard deviation of I50 was reduced from 32% for late shocks to 18% for early shocks. Therefore, shock synchronization improves both DFT and intersubject variability during early fibrillation. As fibrillation duration increases, action potential frequency decreases and periods of diastole occur. Because of these ischemic changes, it is uncertain whether shock timing can produce similar improvements in defibrillation under out-of-hospital conditions.

Action Potentials↗

Efficacy and safety of transcutaneous low-impedance cardiac pacing in human volunteers using conventional polymeric defibrillation pads.

STUDY OBJECTIVES: To assess the safety and efficacy of transcutaneous cardiac pacing using low-impedance defibrillation-type, self-adhesive polymer electrode pads positioned in the same anatomic sites typical of such pad placement in emergency defibrillation attempts. DESIGN: Prospective, randomized, single-blinded normal subject investigation. METHODS: Thirty healthy unmedicated adult volunteers of both sexes were paced transcutaneously to the threshold of capture and beyond by an intensity factor of 125%. A commercial defibrillator-pacer operating in demand mode had its rate set-point higher than the subjects' base-line rate by 125%. Threshold was established as the pulse current required to effect 75% captured beats. Pacing was continued at the 125% level for two minutes, during which subjective discomfort levels were recorded on a 1-to-5 pain scale. RESULTS: All subjects but one were able to complete the study as designed. The single exception complained of intolerable pain early in the two-minute trial. Capture current had a mean value of 80 mA while the pain assessment averaged 3.2 on our five-point scale. No subject showed any untoward cardiovascular effects either during or after the study. CONCLUSION: In normal human volunteers, transcutaneous cardiac pacing with low-impedance polymer pad electrodes is safe. By extrapolation from this study population, it is sufficiently effective to accommodate successfully the vast majority of clinical circumstances likely to be encountered in emergency medicine.

Adult↗

Electrical treatment of cardiac arrhythmias: defibrillation and cardioversion.

The passage of electrical current across the chest and heart to terminate ventricular fibrillation (defibrillation) or organized supraventricular or ventricular arrhythmias (cardioversion) is effective and safe. This paper reviews the physiology, techniques, and rationale for defibrillation and cardioversion. New developments and future directions are discussed. Rapid defibrillation is the most important factor in survival of out-of-hospital ventricular fibrillation.

Electric Countershock↗

Emergency vehicle intervals versus collapse-to-CPR and collapse-to-defibrillation intervals: monitoring emergency medical services system performance in sudden cardiac arrest.

STUDY OBJECTIVE: To compare emergency vehicle response intervals with collapse-to-intervention intervals to determine which of these system data better correlated with survival after prehospital sudden cardiac arrest. STUDY DESIGN: A 22-month case series, collected prospectively, of out-of-hospital cardiac arrests. Times of collapse, dispatch, scene arrival, CPR, and initial defibrillation were determined from dispatch records, recordings of arrest events, interviews with bystanders, and hospital records. SETTING: Southwestern city (population, 400,000; area, 390 km2) with a two-tiered basic life support-advanced life support emergency medical services system. Emergency medical technician-firefighters without electrical defibrillation capability comprised the first response tier; firefighter-paramedics were the second tier. PATIENTS: One hundred eighteen cases of witnessed, out-of-hospital cardiac arrest in adults with initial ventricular fibrillation. MAIN OUTCOME MEASURES: Survival was defined as a patient who was discharged alive from the hospital. RESULTS: Eighteen of 118 patients (15%) survived. Survivors did not differ significantly from nonsurvivors in age, sex, or basic life support or advanced life support response intervals. Survivors had significantly (P < .05) shorter intervals from collapse to CPR (1.7 versus 5.2 minutes) and to defibrillation (7.4 versus 9.5 minutes). CONCLUSION: Collapse-to-intervention intervals, not emergency vehicle response intervals, should be used to characterize emergency medical services system performance in the treatment of sudden cardiac death.

Aged↗