Tensile bond strength of four resin luting agents bonded to bovine enamel and dentin.

STATEMENT OF PROBLEM: The resistance to fracture of ceramic restorations depends on adequate bonding to tooth structure. The dental substrate and the types of resin luting agents used are believed to produce variability in adhesive properties. PURPOSE: The purpose of this study was to evaluate the tensile bond strength of 4 resin luting agents to bovine enamel and dentin. MATERIAL AND METHODS: Forty bovine incisors were embedded in acrylic resin and ground horizontally with water-cooled silicon carbide paper to expose enamel (20 teeth) and dentin at the enamel/dentin junction (20 teeth). Ten standard cone-shaped specimens with a 3-mm diameter base were prepared for each of the following resin cements: Resin Cement, Rely X ARC, Nexus, and Enforce. Five specimens of each material were bonded to enamel and the other 5 to dentin with these resin luting agents and their respective adhesive systems, according to the manufacturers' directions. After 7 days of storage in distilled water at 37 degrees C, specimens were subjected to tensile forces in a universal testing machine at a crosshead speed of 0.5 mm/min until fracture. Bond strength data were analyzed with analysis of variance for substrate and material. Means were compared with Tukey's test at the 0.05 level of significance. RESULTS: Analysis of variance disclosed that both substrate (P<.001) and material (P<.05) demonstrated statistically significant differences, but their interaction was not significant. The bond strengths (MPa) obtained for Resin Cement (11.5 +/- 3.0), Rely X ARC (11.4 +/- 3.1), Nexus (10.0 +/- 1.4), and Enforce (11.8 +/- 2.8) were statistically the same for enamel. For dentin, bond strengths (MPa) for Rely X ARC (9.6 +/- 1.8), Resin Cement (9.3 +/- 0.9), and Enforce (7.8 +/- 2.9) were significantly higher than for Nexus (3.5 +/- 0.8). Significantly higher bond strengths (MPa) were also observed for enamel (11.2 +/- 2.5) than dentin (7.5 +/- 1.6). CONCLUSION: Within the limitations of this study, tensile bond strengths of resin luting agents to enamel were higher than those to dentin, and the bond strength values of Nexus to dentin were significantly lower (P<.05) than the other cements tested.

Adhesiveness↗

An in vitro comparison of tensile bond strengths of noble and base metal alloys to enamel.

STATEMENT OF PURPOSE: Many different surface treatments have been used to increase the bond strength of noble and base metal alloys to enamel, but only a few have been studied. PURPOSE: The purpose of this in vitro study was to compare the tensile bond strength of a tin-plated noble alloy, an Alloy Primer-treated noble alloy, and an airborne particle-abraded base metal alloy, all bonded to enamel with a phosphate-methacrylate resin luting agent. MATERIAL AND METHODS: Seventy noncarious molar teeth were extracted, cleaned, and embedded in autopolymerizing acrylic resin with the buccal surface of the teeth exposed. Seventy wax patterns (4-mm diameter x 2-mm thickness) were waxed, invested, and cast-50 with a noble alloy (Argedent 52) and 20 with a base metal alloy (Argeloy N.P.). Twenty of the noble alloy specimens were tin-plated (TP), 20 noble alloy specimens were treated with Alloy Primer (AP), and 20 base metal alloy specimens were airborne particle abraded (AA). All specimens were luted with a phosphate-methacrylate resin luting agent (Panavia F) and stored in 100% humidity at 37 degrees C, half for 24 hours and half for 7 days. Ten noble alloy specimens were tin-plated and stored in water for 48 hours (aged) before cementation and then stored in water for 24 hours after cementation. These specimens were used to test whether there is an advantage to aging the tin-plated surface in water before cementation. All specimens were thermocycled (5 degrees to 55 degrees C) for 500 cycles and then tested for tensile bond strength (TBS), measured in MPa, with a universal testing machine at a crosshead speed of 0.5mm/min. Various castings (n=6 per test group) were randomly selected from each group and inspected under a scanning electronic microscope to determine mode of failure. The mean values and standard deviations of all specimens were calculated for each group. A 2-way analysis of variance (ANOVA) was performed, and multiple pairwise comparisons were then completed with post hoc Tukey test (alpha=.05). RESULTS: The TBS of the tin-plated noble alloy specimens bonded to enamel (24 hours: 9.33 +/- 1.31 MPa; 7 days: 11.65 +/- 1.55 MPa) was significantly greater than the Alloy Primer noble alloy specimens (24 hours: 6.11 +/- 1.01 MPa; 7 days: 5.45 +/- 1.22 MPa) (P <.001). The Alloy Primer noble alloy group showed the lowest TBS compared with the tin-plated noble alloy and airborne particle-abraded base metal alloy group (24 hours: 10.61 +/- 1.41 MPa; 7 days: 6.94 +/- 1.40 MPa). The tin-plated noble alloy specimens showed greater TBS after storage for 7 days in distilled water compared with storage for 24 hours (24 hours: 9.33 +/- 1.31 MPa; 7 days: 11.65 +/- 1.55 MPa). Aging the tin-plated noble alloy for 48 hours in 37 degrees C (9.17 +/- 1.68 MPa) prior to cementation did not increase the TBS to enamel. The airborne particle-abraded base metal alloy showed significantly lower TBS at the 7-day storage time compared to the 24-hour storage time (24 hours: 10.61 +/- 1.41 MPa; 7 days: 6.94 +/- 1.40 MPa) (P <.001). SEM examination of the debonded metal and enamel surfaces showed mixed (adhesive and cohesive) failures for all groups. CONCLUSION: Tin-plating a noble alloy produced the highest bond strength to enamel. Storing the tin-plated noble alloy in 37 degrees C distilled water for 48 hours before cementation did not result in a change in TBS. Using an Alloy Primer with a noble alloy resulted in statistically significant lower TBS than tin-plating.

Analysis of Variance↗

Ultrastructural immuno-gold localization of immune deposits in human renal biopsies.

Ultrastructural immunolocalization of immunoglobulins has the potential to supply new information about immune-mediated glomerulonephritides. Most previous studies have used immunoperoxidase pre-embedding techniques to identify the components of glomerular deposits. These techniques have not been satisfactory as they only allowed the identification of one antigen (immunoglobulin) in each portion of tissue under investigation and also caused obliteration of labelled structures by the dense reaction product. Several studies have used colloidal gold as a post-embedding label, but these have been unable to localize immunoglobulins or complement components in epoxy resin embedded tissue. The present study uses glutaraldehyde-fixed tissue which is embedded in a polar acrylic resin. This technique results in good ultrastructural detail while allowing maximum antigen retention and, when combined with colloidal gold labelling, it provides the optimal procedure for ultrastructural immune localization. A spectrum of immunologically induced renal diseases is examined using this technique, the results of which correlate well with immunofluorescence.

Complement System Proteins↗

The resistance to tensile, compression, and torsional forces provided by four post systems.

This study measured the force required to displace four different endodontic posts (an experimental, Para-Post, Flexi-Post, and V Lock) when tensile, torsion, or compressive forces were applied. Extracted mandibular premolars were decoronated at the cementoenamel junction, the roots were divided into groups of similar size, and the pulpal tissue was removed. The canals were enlarged, cleaned, and filled with gutta percha. Post preparations were made, and the posts were cut and cemented into the post spaces with resin cement. The roots were notched with a separating disc and lowered into a metal tube filled with acrylic resin. Two Minim pins were placed into the coronal dentin paralleling the post. Composite resin cores were made around the coronal 4 mm of the posts and the two pins for 10 specimens from each group. The specimens were placed into a standardized fixture and a load applied until failure. The tensile load required to pull the experimental post and resin was significantly less than the load required to remove the threaded posts. Flexi-Posts provided the greatest resistance to torsion and tensile loading. The compressive load required to fracture the core over the V-Lock post was significantly greater than the other post systems.

Dental Cements↗

Restoration of inadequate occlusal face height by using resin bonded to etched metal removable prosthesis.

The resin bonded to etched metal casting of a removable partial denture was used anteriorly in combination with posterior acrylic resin teeth to restore patients with mandibular overclosure. The procedure is simple, esthetic, conservative, inexpensive, and not time-consuming. Patients maintained their new occlusal facial height with normal functional activity. The remaining natural teeth showed no signs of changes in 6 months in either opposing tooth structure or the periodontium.

Dental Occlusion↗

Effect of residual caries-disclosing solutions on microleakage of a dental adhesive system.

OBJECTIVE: The purpose of this in vitro study was to determine the effect of residual caries-disclosing dyes on a dentinal adhesive system and accompanying resin composite, using microleakage as the quantifying criterion. METHOD AND MATERIALS: The dye pretreatment groups (10 teeth in each group, n = 60) were as follows: Group 1, Caries Detector; group 2, Cari-d-tect; group 3, Seek; group 4, Snoop; group 5, To Dye For; and group 6, control (no dye pretreatment). Circular preparations were cut on the facial or lingual surface of each tooth. Caries-disclosing dyes were placed on the preparations; this was followed by treatment with 35% phosphoric acid etchant, application of a Single-Bond adhesive, and insertion of Z-100 hybrid resin composite. Following thermocycling, the teeth were sealed with nail varnish, placed in methylene blue dye, invested in acrylic resin, labeled, and sectioned. Leakage was examined (20x magnification) by dye penetration at the occlusal and gingival surface positions of the specimen blocks using an ordinal ranking system. The data were analyzed using two-way analysis of variance with P < .05 as the significance level. RESULTS: Results of the study showed that, at the occlusal surface position of the restorations, significantly greater leakage was exhibited by To Dye For compared to Snoop. At the gingival surface position, significantly greater leakage was exhibited by: (1) Caries Detector, Cari-d-tect, Seek, and To Dye For compared to the controls; and (2) To Dye For compared to Snoop. When comparing the same dye pretreatment groups with respect to occlusal versus gingival surface positions, significantly greater leakage was exhibited at the gingival surface positions, except for the control group. CONCLUSION: Our data showed that all dye groups leaked (except Snoop at the occlusal surface position), and significantly greater leakage was exhibited at the gingival surface position of all groups except the control. Snoop revealed the least leakage of all the dyes tested.

Analysis of Variance↗

[The relation between contour and stress of metal-resin interface].

The interface residual stress is closely related to the interface contour of metal-resin, which affects the service life of metal-resin restoration. The authors researched the relationship between the interface residual stress of Ni-Cr alloy-acrylic resin and the different interface contours such as the curvature, convexity, concavity, width and the angle of interface. The result showed that the stress analysis with the Laser-optical microscopic analyzer is an advanced method to study metal-resin interface stress. The interface contour of concave, shallow cavity without sharp margin is desirable for reducing the interface stress.

Composite Resins↗

Stress relaxation of heat-activated acrylic denture base resin in the mold after processing.

STATEMENT OF PROBLEM: Stress relaxation of polymethyl methacrylate has been reported, but no studies have investigated residual stress relaxation in heat-activated acrylic denture base resin fabricated by the polymer-monomer mixture method. PURPOSE: This study evaluated the development of residual stress relaxation and clarified how restricted time in the stone mold influenced stress relaxation of heat-activated acrylic denture base resin after processing. MATERIAL AND METHODS: Flat, dumbbell-shaped specimens were used. Thermocouples and strain gauges were embedded in resin for measuring temperature and strain at the dough-stage of resin packing. To clarify the stress relaxation in the stone mold, specimens were removed from the mold by deflasking at 4 hours after from the start of bench cooling (immediately after reaching room temperature; control), and 1 day, 3, 5, and 10 days from the start of bench cooling. RESULTS: Shrinkage strains at deflasking were two thirds for 1 day restriction, one half for 3 and 5 days restriction, as compared with the control. CONCLUSIONS: This study suggested that removing a denture base fabricated by heat-activated acrylic denture base resin from the stone mold only after keeping it in stone mold for at least 1 day or more was effective for reducing deformation of the denture base.

Acrylic Resins↗

Probability of failure of orthodontic brackets bonded with different cementing agents.

OBJECTIVES: The aim of this study was to compare the maximum loads at failure and the probability of failure of three glass ionomer cements and a composite cement bonding orthodontic brackets to human premolar teeth. METHODS: The cements studied included a conventional glass ionomer cement, two resin-modified glass ionomer cements and a composite cement. The roots of 200 human premolar teeth were embedded in acrylic resin and the buccal enamel surface of the crown prepared as required. Each cement used to bond the bracket to the enamel was weighted, and light-cured where required. The specimens were stored for 10 min or 24 h at 37 degrees C and 100% humidity. A tensile shear force was applied via a wire loop placed under the wings of the bracket. The maximum load at failure was noted and subjected to Weibull analysis to compare probabilities of survival for each cement. The data obtained was also analyzed using a Kruskal-Wallis test followed by comparison of the groups using Mann-Whitney tests. RESULTS: Comparison of the loads at failure revealed that the composite cement was significantly stronger than the glass ionomer cements at 10 min and 24 h (p<0.05). Weibull analysis of the results gave values for the Weibull moduli and probabilities of survival for an orthodontic bracket under a given load for each cement at 10 min and 24 h. SIGNIFICANCE: . Glass ionomer cements give a number of clinically significant advantages over composite cement in the retention of brackets. The resin-modified glass ionomer cements tested had a higher probability of survival than the conventional cement tested at 24 h. However, further improvements in their early bond strength would be clinically beneficial.

Bisphenol A-Glycidyl Methacrylate↗

In vitro fracture resistance of teeth with dentin-bonded ceramic crowns and core build-ups.

PURPOSE: To assess the fracture strength of dentin-bonded crowns placed on cores of amalgam, resin composite and viscous glass-ionomer. METHODS: 40 sound maxillary premolar teeth were selected. These were mounted in acrylic resin in stainless steel molds. The palatal cusp of each tooth was removed in a standardized manner to simulate a core build-up preparation. Teeth were randomly divided into four groups, and each group was allocated a core material. For Group A, the core was pin-retained amalgam, for Group B the core was bonded amalgam, for Group C the core material was resin composite and for Group D the core material was high-viscosity glass-ionomer material. Cores were then constructed to the original tooth dimensions. A standardized crown preparation was made, impressions taken and an all-ceramic crown constructed in feldspathic porcelain. The crowns were luted in position using a dentin-bonding agent/dual cure resin-composite cement and the completed specimens subjected to compressive loading in a Universal Testing machine at 1 mm/minute. RESULTS: The mean forces to produce fracture of the crowns were 1.58 kN (+/- 0.41), 1.35 kN (+/- 0.44), 1.25 kN (+/- 0.24), and 1.12 kN (+/- 0.25) respectively for groups A, B, C and D. Statistical analysis by ANOVA indicated that the pinned amalgam group performed significantly better than the glass-ionomer group (P > 0.05).

Aluminum Silicates↗

The effect of primers and surface characteristics on the adhesion-in-peel force of silicone elastomers bonded to resin materials.

Facial prostheses, when used in conjunction with craniofacial implants, require a retentive matrix to hold attachments and/or magnets. The retentive matrix is usually fabricated with autopolymerizing acrylic resin or a visible light-polymerized resin. The purpose of this study was to compare the adhesion-in-peel force of a silicone adhesive to autopolymerizing polymethyl methacrylate and light-polymerizing urethane dimethacrylate gel with two surface textures: (1) pumice polish only or (2) pumice polish and bead retention, and two surface primers: (1) Dow Corning 1205 primer or (2) Dow Corning S-2260 primer. The 1205 primer produced an adhesion-in-peel force that was statistically significantly stronger (p < 0.05) regardless of which type of resin or surface preparation was used.

Adhesiveness↗

Dentist's occupational allergic contact dermatitis caused by coconut diethanolamide, N-ethyl-4-toluene sulfonamide and 4-tolyldiethanolamine.

Dental personnel are exposed to many sensitizing compounds at work and often develop multiple delayed allergies. Here we report on a dentist who got sensitized to several products that have not, or only seldom, caused sensitization earlier. These products were: coconut diethanolamide from her handwashing liquids, N-ethyl-4-toluene sulfonamide, a resin carrier in dental materials for isolating cavities underneath restorations, and 4-tolyldiethanolamine, an accelerator for inducing polymerization of dental acrylic resins at room temperature. The patient also had allergic patch test reactions to formaldehyde, phenol-formaldehyde resin, fragrance mix, and lauryl monoethanolamide, possibly from occupational exposure.

Allergens↗

How to make microwavable denture flasks.

One can make a microwavable denture flask that will accommodate obturators and other large intraoral prostheses. A method for making a dental stone flask pattern and a latex mold makes it possible to produce fiberglass flasks strong enough for compression molding. These flasks are economical to produce and are made from the fiberglass liquid resin that is used in automobile body repairs. The fiberglass liquid resin is strengthened by the addition of dental stone and chopped fiberglass strands. The resultant flasks allow successful microwave polymerization of acrylic resin for denture bases while still being able to follow conventional flasking and packing techniques.

Dental Equipment↗

[Preparation of carbon fiber reinforced fluid type resin denture (author's transl)].

Transverse strength of cured fluid resins is weaker than that of the heat cured. We have studied to improve the mechanical strength of self-cured acrylic resin by application of carbon fibers as reinforcement and simple methods which must be acceptable for technicians are proposed. A cloth type carbon fiber was the best reinforcement among studied carbon fibers such as chopped or mat. The chopped fibers were difficult to mix homogeneously with fluid resins and effectiveness of the reinforcement was low. Breaking often occurred at the interface between the reinforcement and resin in the cases of mat which gave defects to the test specimens. To prepare reinforced denture, the cloth was trimmed on the master cast after removal of wax and the prepreg was formed with the alginate impression on the cast by Palapress and the cloth. Other steps were same as the usual fluid resin.

Carbon↗

Effect of eugenol-containing temporary cements on bond strength of composite to enamel.

The purpose of this study was to find out the degree to which eugenol-containing temporary cements or temporary filling materials affected shear bond strength of a dual-cure resin luting cement to acid-etched enamel. For this purpose 56 human caries-free third molars were embedded in acrylic resin and cross sectioned mesiodistally. One of the corresponding halves was covered with Temp-Bond (eugenol-containing, Group 1), Provicol (eugenol-free, Group 2), ZOE (Group 3), and eugenol (Group 4). The other half of each sectioned tooth was kept clean and served as a control. After 1 week the cements were removed; the pure eugenol group (Group 4) was terminated after 24 hours. Plastic cylinders were filled with Dual Cement and placed on the etched enamel and light cured. Shear bond strength data were recorded using a Zwick Universal Testing Machine, and the mode of failure was diagnosed using a light microscope. Significant differences in shear bond strength could neither be found between the treated halves and the controls nor among the four groups pretreated with eugenol-containing or eugenol-free temporary cements. Based on the results of this study, no adverse effects of eugenol on shear bond strength of a resin luting cement to enamel could be found.

Acid Etching, Dental↗

Swelling of poly(methyl methacrylate) resin at the repair joint.

This study investigated the thickness of a swollen layer between heat-activated and autopolymerized denture base polymer based on poly(methyl methacrylate) and autopolymerized repair acrylic resin. The repair surfaces of polymerized poly(methyl methacrylate) resin specimens (n = 5) were wet with methyl methacrylate liquid for 0, 0.5, 3, 30, or 60 minutes before the mixed repair resin was applied and polymerized to the surface of the specimen. The specimens were wet ground to a thickness of 0.15 mm, and the repair joint was examined using a light microscope. The thickness of the layer of swollen poly(methyl methacrylate) at the repair joint was measured from the micrographs. Both the type of polymer, ie, heat-activated or autopolymerized, and the wetting time of the repair surface with methyl methacrylate had a significant effect on the thickness of the swollen layer (P < .001). Prolonged wetting time of the repair surface of the autopolymerized poly(methyl methacrylate) increased the thickness of the swollen layer (r = .944, P = .000), but had less effect on the thickness of the swollen layer of heat-activated poly(methyl methacrylate) (r = .391, P = .005). This study suggests that methyl methacrylate diffuses more easily into an autopolymerized poly(methyl methacrylate) than into heat-activated poly(methyl methacrylate) during the repair of denture base polymer.

Analysis of Variance↗

Bonding strength between a hard chairside reline resin and a denture base material as influenced by surface treatment.

Direct relining of dentures made with hard chairside reline resins is faster than laboratory-processed reline systems and the patient is not without the prosthesis for the time necessary to perform the laboratory procedures. However, a weak bond between the autopolymerizing acrylic reline resins and the denture base material has been observed. This study evaluated the effect of six different surface treatments on the bond strength between a hard chairside reline acrylic resin and a heat-cured acrylic resin. Specimens of the heat-cured acrylic resin were divided into seven groups. One of these groups remained intact. In the other groups, a 10-mm square section was removed from the centre of each specimen. The bonding surfaces were then treated with (i) methyl methacrylate monomer, (ii) isobutyl methacrylate monomer, (iii) chloroform, (iv) acetone, (v) experimental adhesive and (vi) no surface treatment -- control group. Kooliner acrylic resin was packed into the square sections and polymerized. The bonding strength was evaluated by a three-point loading test. The results were submitted to one-way analysis of variance (ANOVA) followed by a Tukey multiple range test at a 5% level of significance. No significant difference was found between the surface treatment with Lucitone 550 monomer or chloroform, but both were stronger than the majority of the other groups. The bond strength provided by all the surface treatments was lower than that of the intact heat-cured resin.

Acetone↗

On-resin native chemical ligation for cyclic peptide synthesis.

A novel cysteine derivative, N(alpha)-trityl-S-(9H-xanthen-9-yl)-l-cysteine [Trt-Cys(Xan)-OH] has been introduced for peptide synthesis, specifically for application to a new strategy for the preparation of cyclic peptides. The following steps were carried out to synthesize the cyclic model peptide cyclo(Cys-Thr-Abu-Gly-Gly-Ala-Arg-Pro-Asp-Phe): (i). side-chain anchoring of Fmoc-Asp-OAl via its free beta-carboxyl as a p-alkoxybenzyl ester to a solid support; (ii). stepwise chain elongation of the peptide by standard Fmoc/tBu solid-phase chemistry; (iii). removal of the N-terminal Fmoc group; (iv). coupling of Trt-Cys(Xan)-OH; (v). selective Pd(0)-promoted cleavage of the C-terminal allyl ester; (vi). coupling of the C-terminal residue, i.e., H-Phe-SBzl, preactivated as a thioester; (vii). selective removal of the N(alpha)-Trt and S-Xan protecting groups under very mild acid conditions; (viii). on-resin cyclization by native chemical ligation in an aqueous milieu; and (ix). final acidolytic cleavage of the cyclic peptide from the resin. The strategy was evaluated for three supports: poly[N,N-dimethacrylamide-co-poly(ethylene glycol)] (PEGA), cross-linked ethoxylate acrylate resin (CLEAR), and poly(ethylene glycol)-polystyrene (PEG-PS) graft resin supports. For PEGA and CLEAR, the desired cyclic product was obtained in 76-86% overall yield with initial purities of approximately 70%, whereas for PEG-PS (which does not swell nearly as well in water), results were inferior. Solid-phase native chemical ligation/cyclization methodology appears to have advantages of convenience and specificity, which make it promising for further generalization.

Cyclization↗