Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “VENTILATION”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95Linked to original sources

Prevalence of myocardial ischemia during mechanical ventilation and weaning and its effects on weaning success.

BACKGROUND: Myocardial ischemia may be considered both a consequence of weaning from ventilation and a potential cause of weaning failure. A limited number of investigations have evaluated myocardial ischemia during mechanical ventilation and weaning and its effect on weaning success. The purpose of this pilot investigation was to determine the prevalence of myocardial ischemia in a diverse group of medical intensive care unit (MICU) patients during baseline mechanical ventilation, during weaning using continuous positive airway pressure, and up to 24 hours after extubation and to evaluate the relationship between ischemia and weaning failure. METHODS: This study was a prospective, repeated-measure, descriptive investigation that studied 43 ventilated MICU patients. Slightly more than half of participants were male (53%), and participants had a mean age of 51.1 +/- 14.6 years and were ventilated an average of 11.7 +/- 11.3 days. Myocardial ischemia was evaluated by examination of plasma cardiac troponin I, creatine phosphokinase-myocardial band (CK-MB), and ST-segment changes on electrocardiogram. Continuous electrocardiographic data were obtained by a calibrated, frequency-modulated, continuous 3-channel electrocardiographic recorder using leads I, II, and V2. RESULTS: Seventy percent of these participants (n = 30) exhibited ST-segment deviation at some point during data collection (baseline mechanical ventilation, during weaning, after extubation). Twenty-four participants exhibited ST-segment deviation at baseline, 7 during weaning, and 8 after extubation. Nine participants exhibited ST-segment deviation at >1 data collection time point. None had ST-segment deviation at all 3 time points. Cardiac enzyme concentrations were highly variable; five participants demonstrated clinically important increases in either CK-MB and/or troponin I. Thirty-five percent of participants required >1 weaning trial. Participants who exhibited ST-segment deviation during baseline ventilation were 60% more likely to fail their initial weaning trial. There were no significant differences in CK-MB or troponin I levels between those participants who were successfully weaned with 1 trial and those who failed to wean during that first trial. CONCLUSIONS: Silent myocardial ischemia was a common occurrence in this diverse group of MICU patients, although only 21% had previously diagnosed coronary disease. Clinicians must be aware of the potential for silent ischemia, monitor and evaluate their patients for such, and intervene to promote optimal cardiovascular function, particularly during the stress of ventilator weaning.

Adult↗

Investigation of surface changes in different types of ventilation tubes using scanning electron microscopy and correlation of findings with clinical follow-up.

OBJECTIVES: Like all biomaterials, ventilation tubes are subject to formation of bacterial biofilm on their surfaces. There might also be surface changes. This increases the risk of complications associated with ventilation tubes. In this study, we examined two groups of ventilation tubes using scanning electron microscopy (SEM) to investigate biofilm growth and surface deformations. METHODS: There were two different types of ventilation tubes used, the first group consisted of 30 silicone tubes and the second group consisted of 16 ionized, processed silicone tubes. The tube samples included those that were either removed or those that were extruded into the ear canal. We investigated the association between scanning electron microscopy findings and the complications that developed during the treatment. RESULTS: As a result of this study, it is found that the ionized, processed silicone tubes are superior to other silicon ventilation tubes in regard to biofilm growth (z=-3.925, p=0.000, <0.0001) and surface deformations (chi(2)=9.120, p=0.003, <0.01). Furthermore, we observed that as the duration of the ventilation tube application increases, bacterial biofilm growth (chi(2)=10.718, p=0.005, <0.01) and surface deformations (z=-2.940, p=0.003, <0.01) increase. We also observed that biofilm growth and occurrence frequency were related to "otorrhea" (chi(2)=10.258, p=0.036, <0.05) and "plugging" (chi(2)=7.952, p=0.019, <0.05) complications. CONCLUSION: In this study, we show that ionized, processed silicone ventilation tubes are more robust to bacterial biofilm growth compared to other silicone ventilation tubes used in this study and that the "otorrhea" and "plugging" complications are reduced with the decrease of bacterial biofilm growth.

Biocompatible Materials↗

Relationship between transducer type and low-frequency hearing loss for patients with ventilation tubes.

OBJECTIVE: To determine the relationship between the type of transducer used to perform pure-tone audiometry and the appearance of low-frequency hearing loss at 250Hz and 500Hz for patients with ventilation tubes. METHODS: Air conduction thresholds at 250Hz and 500Hz were measured using Telephonics TDH-49 supra-aural headphones and EARTONE 3-A insert earphones for patients with normal ears (N=16) and patients with ventilation tubes (N=114). Tympanometry was performed on each patient prior to audiometric testing. Audiometric test results obtained in normal ears were compared to results for patients with ventilation tubes. For analysis, the ventilation tube patients were separated into two groups, representative of ventilation tube type. RESULTS: Audiometric results obtained using the two transducer types at 250Hz and 500Hz revealed significant differences in threshold for patients with ventilation tubes. Thresholds obtained using insert earphones were generally worse than thresholds obtained using supra-aural headphones for this group. On average, difference in threshold was 14.15dB worse with insert earphones at 250Hz and 9.75dB worse with insert earphones at 500Hz for patients with Sheehy tubes. Average difference in threshold for patients with Donaldson tubes was 13.93dB worse with insert earphones at 250Hz and 8.93dB worse with insert earphones at 500Hz. In addition, thresholds were more variable for patients with ventilation tubes than normal ears at 500Hz. There were no significant differences in threshold for normal ears using both transducers. CONCLUSIONS: When performing pure-tone audiometry, choice of transducer can influence the accurate identification of a low-frequency hearing loss in patients with ventilation tubes. Low-frequency thresholds were generally worse using insert-style earphones to test subjects with tubes, resulting in the apparent identification of a hearing loss. However, with supra-aural headphones, no low-frequency hearing loss existed. There were no significant differences in threshold values using either transducer in normal ears.

Acoustic Impedance Tests↗

Cost assessment of ventilation and averted dose due to radon in dwellings.

The inhalation dose due to radon and its progenies could be averted by ventilation in dwellings; however, on the other hand the increased ventilation augments the heating cost. Therefore a cost-benefit analysis could contribute to optimise the ventilation rate. In our current work we applied our former defined parameters of the optimising procedure to assess the optimised ventilation and radon concentration in dwellings with average parameters. To assess the inhalation dose rates the time-dependent concentrations of all the progenies were calculated in case of periodic and continuous ventilation as well, at three different radon entry rates (5, 10, 20kBqh(-1)). The optimal ventilation rates in case of continuous ventilation are 0.22, 0.40 and 0.66h(-1), respectively. By these conditions the optimal radon concentration takes 160-210Bqm(-3). According to the more detailed analysis the periodic ventilation gives, in general, a better solution than the continuous one. The Monte Carlo simulations provided a large uncertainty; therefore, before the practical application of the results the uncertainty should be decreased taken into account the local conditions.

Air Pollutants, Radioactive↗

A comparison of the effects of high frequency--low tidal volume and low frequency--high tidal volume mechanical ventilation.

Ten neonates with severe lung disease were studied while mechanically ventilated with standard volume preset infant ventilators, using two different ventilatory patterns. Slow ventilatory rates and high tidal volumes were alternated with rapid rates and low tidal volumes; minute ventilation, FIo2, PEEP, and I:E ratios were held constant. Peak inspiratory pressure, mean airway pressure, expiratory time, Pao2, Paco2, pH, and arterial blood pressure were measured and compared for each frequency-tidal volume combination. The best arterial oxygenation occurred at the combination of settings that produced the highest mean airway pressure and always during low frequency-high tidal volume ventilation (P less than 0.001). Changes in oxygenation appeared to be directly related to changes in MAP. A second experiment examined two different ventilator systems' responses to changes in ventilatory rate. When the rate of one ventilator (Bourns LS104 volume preset) was increased, MAP increased. When the rate of the other ventilator (Bennett PR2 pressure preset) increased, MAP decreased. These observations suggest that there is a direct relationship between MAP and orterial oxygenation, and that the supposed advantages of one ventilatory pattern over the other may be secondary to inadvertent changes in subtle pressure-time relationships within the respiratory cycle and incidental changes in MAP. These changes may vary from one ventilator to another.

Humans↗

Outcome of home mechanical ventilation in children.

A retrospective study of the outcome of home mechanical ventilation in 54 children with chronic respiratory insufficiency was conducted. The children's ages ranged from 4 months to 18 years. Tracheostomies and positive pressure ventilation were used in 33 patients, and negative pressure ventilation in 21 patients. Nine patients were eventually weaned from the ventilator, including three quadriplegic patients in whom electrophrenic stimulation subsequently was used. Over 20 years, there were 17 deaths, including three from ventilator disconnection. Life table analysis showed 1-year survival to be 84%, and 5-year survival 65%. Home mechanical ventilation, with patients cared for by family and friends, cost less (average less than $1000/mo) than registered nurse or hospital care (average $16,000/mo). There was no significant difference in the number of deaths between patients cared for by registered nurses 24 hours a day and those cared for by family and friends. Home mechanical ventilation may be a reasonably safe and cost-effective alternative to prolonged hospitalization for the ventilator-dependent child.

Adolescent↗

Comparison of the incidence of cholesteatoma surgery before and after using ventilation tubes for secretory otitis media.

Inserting ventilation tubes has become, probably, the most common surgical operation performed on children in the free world. In our study, we attempted to examine whether the widely used procedure of inserting ventilation tubes in children with secretory otitis media is indeed justified in the long term. For this purpose, we have studied the influence of the procedure on the formation of cholesteatoma by comparing the incidence of cholesteatoma surgery before and after using ventilation tubes in our department. The data were divided into two periods. The first period included the number of operations in the 10 years (1961-1970) before ventilation tubes were used as a routine treatment for secretory otitis media in our department. The second period included the number of operations in the last 10 years (1989-1998) following the usage of ventilation tubes over 30 years. We found that the number of cholesteatoma operations has decreased, from 413 operations in the 10 years before ventilation tubes were used to 228 operations over the last 10 years. The number of operations per 10000 of the entire population has decreased from 20 operations to 6.6 operations after using ventilation tubes (P=0.0000001). We have shown that the incidence of surgery for cholesteatoma has been declining. Having analyzed the options that might cause this decline, we believe that using ventilation tubes in secretory otitis media might help to reduce the incidence of cholesteatoma surgery in the long term.

Adolescent↗

Transtracheal needle catheter ventilation in complete airway obstruction: an animal model.

Transtracheal needle catheter ventilation (TNCV) may be used as an alternative airway when contraindications to endotracheal intubation exist. A feline model tested the efficacy of low-flow oxygen delivery, and initial data were gathered to define proper catheter calibers to effect adequate oxygenation and ventilation. Cats were anesthetized, trachea intubated, and ventilated for 30 minutes with a pressure-regulated ventilator. Arterial and venous pressures were monitored, and a chest tube was inserted to measure intrathoracic pressures. Arterial blood gas analysis was performed every five minutes during the baseline period. The endotracheal tube was then removed, the trachea cross-clamped, and TNCV instituted. Oxygen flow rates of 1, 3, and 5 L/min were varied with catheter sizes of 14, 16, and 18 g. Data demonstrated that TNCV provided adequate oxygenation and ventilation with flow rates of 3 and 5 L/min with the 14- and 16-g catheters. Satisfactory oxygenation could be obtained with these flow rates with the 18-g catheter, but ventilation was inadequate. Ventilation was unsatisfactory with the 1 L/min flow rate in all catheter sizes. These preliminary data indicate that a minimum catheter:trachea cross-sectional area ratio of 0.03 may be required to obtain oxygenation and ventilation with low-flow oxygen rates of 3 to 5 L/min in cats.

Airway Obstruction↗

[The eternal promise of high frequency ventilation].

High frequency oscillatory ventilation (HFOV) is based on the application of continuous pressure in the respiratory system, which assures oxygenation, on which a small oscillation that permits ventilation is added. Although this ventilation form seems to comply with the requirements necessary to minimize the pulmonary lesion associated to mechanical ventilator-induced lung injury in acute lung injury, as several experimental studies suggest, its advantages in the clinical practice must still be demonstrated. Part of this lack of evidence is due to methodological problems of the studies published. However, the major limitation is that it has not been compared against a conventional ventilation strategy with low volumes/pressures. At present, it seems that high frequency ventilation is limited to cases refractory to conventional ventilation. A more extensive knowledge on how to optimize high frequency ventilation is needed before proposing clinical trials having greater scope.

High-Frequency Ventilation↗

[A study of 11 ventilators for anesthesia: laboratory testing].

Eleven anaesthesia ventilators were instrumentally tested under various conditions. They included: Excel and Modulus II Plus (Ohmeda); 710 and Servo anaesthesia circle 985 (Siemens); Jollytronic (Soxil) and Elsa (Engström); SA2 and Cicero (Dräger); ABT 4,300 (Kontron); Monnal A and the prototype Alys (Taema). The test circuit comprised a two compartment model lung, a pneumotachograph, a pressure gauge in the "airway". The volume was calculated as the integral of flow rate. Each machine was calibrated by the firms' technicians. Before each test, the pneumotachograph was calibrated using a 11 air syringe and the pressure gauge with a 5 cm water column. Each machine ventilated the model lung for 30 min before starting the tests. There were five tests: 1) reliability of the machine's spirometer, 2) reliability of the ventilation rate, 3) reliability of pressure measurements, 4) effect of increasing fresh gas flow on spirometry, 5) effect of increasing downstream resistances. In usual simulated ventilatory conditions, all the machines accurately delivered the setted ventilation and spirometric measurements were with minimal error only. Several ventilators (SA2, Excel, 710, Elsa, ABT 4,300) did not succeed in maintaining their performances when compliance was strongly decreased or resistance of the test lung notably increased. Resistance in the circuit during simulated spontaneous ventilation was < 3.6 cmH2O.l-1.s-1. Increasing fresh gas flow raised the minute volume delivered in six ventilators. It is concluded that, during extreme ventilatory conditions, the inspired volume must be adjusted so as to maintain the inspired tidal volume. However, ventilators which increase inspiratory time in response to an increased mechanical load cannot be adjusted by this way.

Anesthesia, Closed-Circuit↗

Effect of different ventilation regimens on ewes' milk and Canestrato Pugliese cheese quality in summer.

The influence of three different ventilation regimens on air pollution in sheep houses and on the quality of ewe milk and of Canestrato Pugliese cheese was investigated during the summer season. The experimental treatments were low ventilation regimen (VR=35 m3/h per ewe) split in 30-min ventilation cycles (LOV-30); moderate ventilation regimen (VR=70 m3/h per ewe) split in 30-min ventilation cycles (MOV-30); moderate ventilation regimen (VR=70 m3/h per ewe) split in 60-min ventilation cycles (MOV-60). The LOV-30 milk had higher microbial load and bulk milk somatic cell count (BMSCC) and resulted in a weaker casein matrix in the curd compared with the MOV-30 and MOV-60 treatments. At 45 d of ripening, the LOV-30 cheeses had a lower casein content and higher non-casein nitrogen (NCN) and water-soluble nitrogen (WSN) contents than the MOV-30 and MOV-60 cheeses. Urea-polyacrylamide gel electrophoresis (urea-PAGE) of the pH 4.6-soluble N extract showed that the MOV-60 cheeses had fewer bands derived from casein (CN) hydrolysis than the LOV-30 or MOV-30 cheeses, despite its having exhibited the highest plasmin (PL) activity levels. Our results suggest that the ventilation regimen is critical in dairy sheep housing for optimizing the hygienic quality of ewe milk and the proteolytic processes occurring in Canestrato Pugliese cheese during ripening.

Animals↗

Effects of ventilation rate and of dietary protein level in an intensive dairy sheep system on the features of Canestrato Pugliese cheese.

Effects of ventilation rate and of dietary protein level in an intensive dairy sheep system on the features of Canestrato Pugliese cheese were studied. Cheeses were manufactured from the bulk milk obtained from ewes subjected to four different experimental treatments: (1) low dietary crude protein (CP) of 13% in dry matter (DM) at a low ventilation rate (23.5 m3/h per ewe) (LPLV); (2) low dietary CP at a moderate ventilation rate (47 m3/h per ewe) (LPMV), (3) moderate dietary CP of 16% DM at a low ventilation rate (MPLV); and (4) moderate dietary CP dietary at a moderate ventilation rate (MPMV). Bulk milk and cheeses (at 1, 15, 45 and 90 d of ripening) were analysed for chemical composition, N fractions and plasmin-plasminogen activities. The pH 4.6-soluble and insoluble N fractions were analysed by urea-PAGE. Bulk milk from ewes receiving the low CP diet displayed higher casein and lower urea contents. Ewes subjected to the low ventilation rate displayed a higher plasminogen activity in milk, whereas no differences emerged among treatments in the conversion of zymogen to plasmin. During ripening the plasmin-plasminogen system in cheese did not display significant changes across treatments. At 90 d of ripening, the cheese produced with milk from ewes receiving the low CP diet and exposed to the low ventilation rate displayed more markedly stained bands in the area of gamma-caseins in pH 4.6-insoluble N fraction. As from 15 d of ripening, the pH 4.6-soluble fraction showed a greater number of bands in the LPMV and MPMV than in the LPLV and MPLV cheeses. The results showed that Canestrato Pugliese cheese manufactured with milk from ewes fed the low CP diet and exposed to the moderate ventilation rate was characterized by higher protein and casein content in the fresh cheese and by a greater proteolysis after 90 d of ripening.

Animal Feed↗

Combined effects of high-frequency ventilation and surfactant treatment in experimental meconium aspiration syndrome.

BACKGROUND: Deterioration of lung function in meconium aspiration syndrome may in part be due to inactivation of endogenous surfactant. We evaluated the efficacy of high-frequency ventilation (HFV) and the combination of HFV and surfactant therapy in the management of respiratory failure induced by experimental meconium aspiration in adult rats. METHODS: Animals were anesthetized and tracheotomized, and received via the tracheal cannula a suspension of human meconium (25 mg/ml, dose 4 or 5 ml/kg). After 30 min of conventional ventilation (CV) with 100% oxygen, animals were in respiratory failure as indicated by a decrease in lung-thorax compliance of > or = 30% and PaO2 < 10 kPa. They were then ventilated for an additional 3 h with either CV (frequency 40/min, inspiration time 50%) or HFV (frequency 15 Hz, inspiration time 50%) using comparable mean airway pressures (about 20 cmH2O) and variable FiO2. Subgroups of animals were treated with Curosurf (80 mg/ml, dose 200 mg/kg) 30 min after meconium aspiration; no additional material was instilled in controls. RESULTS: From 30 min onwards, values for PaO2/FiO2 were significantly higher in animals ventilated with HFV without receiving surfactant than in control animals subjected to CV alone (at 120 min; 18 +/- 7.3 vs. 7.4 +/- 0.8 kPa, P < 0.05). Additional improvement in oxygenation was seen in HFV-treated animals receiving Curosurf (at 120 min: 39 +/- 16 kPa: P vs. HFV alone < 0.01). Relative lung volumes at a deflation pressure of 10 cmH2O, expressed as percent of maximum volume, were larger in animals ventilated with HFV than in those undergoing CV (41 +/- 12 vs. 33 +/- 10%; P < 0.05), and were further increased in the groups of animals treated with surfactant and ventilated with HFV (55 +/- 9.9%; P vs. animals ventilated with HFV not receiving surfactant < 0.01) or CV (49 +/- 9.6%; P vs. animals ventilated with CV without receiving surfactant < 0.05). Hyaline membranes, granulocytes in cytospin preparations from lung lavage fluid, and vascular-to-alveolar leak of albumin were less prominent in the HFV than in the CV group, particularly in animals treated with surfactant. CONCLUSION: Our data indicate that HFV, especially in combination with surfactant therapy, may be superior to CV for treatment of respiratory failure in this animal model of meconium aspiration syndrome.

Air Pressure↗

Two methods of weaning persons with quadriplegia from mechanical ventilators.

Two commonly-used methods of weaning individuals with quadriplegia from mechanical ventilators were compared. The medical records were reviewed of 52 patients who were injured at the C3 or C4 levels, were ventilator dependent following their injury, and were treated at the participating facilities. The study subjects had a total of 82 separate wean attempts: 26 utilized intermittent mandatory ventilation, 34 used progressive ventilator-free breathing (T-piece weaning) and 22 used either a combination of these approaches or a different approach. With an overall weaning success rate of 83%, this study demonstrated that individuals with C3 and C4 quadriplegia are indeed candidates for ventilator weaning. Comparing the two weaning methods, progressive ventilator-free breathing was found to be successful more often than intermittent mandatory ventilation (67.6% compared to 34.6%). In addition, progressive ventilator-free breathing appeared superior in its ability to provide a more functional alternative to individuals unable to wean completely.

Adolescent↗

The effect of tidal volumes on the time to wean persons with high tetraplegia from ventilators.

STUDY DESIGN: Retrospective review of patient medical records comparing the outcomes of two groups of individuals with high-level (C3-4) tetraplegia- those with high-volume and those with low-volume mechanical ventilation. OBJECTIVES: To determine if higher volume mechanical ventilation contributes to faster weaning from the ventilator with fewer complications in individuals with ventilator dependent high-level tetraplegia. SETTING: A Model Spinal Injury Center, located in Colorado, USA, which treats patients referred from throughout the Rocky Mountain region as well as other states. METHODS: The medical records of 42 individuals with ventilator dependent C3-4 tetraplegia, admitted consecutively to the Rocky Mountain Regional Spinal Injury System between 1983 and 1993, were reviewed. All had required full-time mechanical ventilation upon admission, but had successfully weaned by discharge. They were divided into two groups that differed with respect to the ventilator tidal volumes used during their treatment and weaning: a large volume group (> 20 mls/kg of body weight) and a smaller volume group (< 20 mls/kg of body weight). RESULTS: Though the two groups were equivalent in neurological level and completeness, muscular function, initial spontaneous vital capacity, the weaning method used (T-piece), and final spontaneous vital capacity, those in the large tidal volume group successfully weaned an average of 21 days faster than the lower tidal volume group (37.6 days vs 58.7 days, P=0.02). They also had significantly less atelectasis (P=0.01) than the lower tidal volume group. CONCLUSION: This research suggests that the use of higher ventilator tidal volumes may speed up the weaning process and lessen respiratory complications. Because of the potential for this to decrease the length and cost of the rehabilitation programs for persons with high-level tetraplegia, further large-scale research is needed to verify these single-center findings.

Adolescent↗

Distribution of pulmonary ventilation and perfusion measured simultaneously in awake goats.

Gravity has been regarded as the major determinant for local pulmonary perfusion and ventilation. Recent reports, describing major gravity independent heterogeneity in both variables, have questioned the importance of gravity. We asked to what extent ventilation and perfusion were related, and if they showed similar distributions along the vertical axis in the lung. We gave 99mTc-aerosols as tracers for ventilation and radioactive microspheres as blood flow tracers in five awake goats over 4 min. Ventilation and perfusion were determined in approximately 1.5 cm3 pieces of the lung. For both variables the vertical distribution could vary considerably from lung to lung, but within each lung the two distributions were similar. Both ventilation and perfusion were heterogeneously distributed (CV approximately 40% for both), they were highly correlated (r = 0.81) and the average 25-75-interpercentile interval for ventilation to perfusion ratio (0.84-1.13) was significantly less wide than for both ventilation (0.76-1.38) and perfusion (0.76-1.40). Some pieces were considerably overventilated while a few were correspondingly underventilated. This could indicate that perfusion is adjusted to ventilation in normoxic lungs with a low sensitivity to overventilation.

Animals↗

Mechanical ventilation protects one-storey single-dwelling houses against increased air humidity, domestic mite allergens and indoor pollutants in a cold climatic region.

BACKGROUND: Poor ventilation in modern, highly insulated housing is an important factor in promoting indoor humidity levels to exceed 7 g/kg in cold climatic regions. OBJECTIVE: To investigate the ventilation rate in houses with different ventilation systems in relation to indoor air humidity, domestic mite allergen levels and volatile organic compounds (VOC). METHODS: Measurements were performed regarding ventilation rate, indoor temperature, air humidity, mattress mite allergen concentrations using enzyme-linked immunosorbent assay and total indoor VOC in 59 similarly constructed one-storey single-dwelling houses. In 22 of the houses, a mechanical supply and exhaust ventilation were installed after construction. RESULTS: In only five of the houses with mechanical supply and exhaust ventilation the air exchange rate per hour (ACH) was below 0. 5 compared with 24 of the 29 houses with natural ventilation (OR = 0. 06, CI 95% 0.01-0.2). None of the 23 houses with an ACH >/= 0.5 had an absolute indoor humidity (AIH) of 7 g/kg air or more, compared with 10 of the 36 houses with an ACH < 0.5 (P = 0.01 ). In none of the 23 houses with an ACH >/= 0.5 were concentrations of mite allergen exceeding 2 microg/g of dust found, compared with six of the 36 houses (17%) with an ACH below 0.5 (P = 0.04). Further, 10 of the 34 houses with a total VOC exceeding 200 microg/m3 had mite allergen in mattress dust exceeding 0.5 microg/g, compared with one of the 22 houses with VOC < 200 microg/m3 (P = 0.04). CONCLUSION: The study shows that in modern, highly insulated, one-storey single-dwelling houses in cold temperate regions, mechanical ventilation increases the possibility of reaching an ACH of >/= 5 which protects against indoor humidity levels contributing to mite survival as well as high levels of indoor air pollutants in winter.

Air Pollution, Indoor↗

Long-term ventilation tubes: results of 726 insertions.

Patients with chronic or recurrent otitis media with effusion who do not respond to treatment with conventional ventilation tubes are often treated with long-term ventilation tubes. The aim of this retrospective study was to determine the extrusion and complication rates of long-term ventilation tubes. The median ventilation time of the tubes was 31.5 months. The most common complication was otorrhoea. One episode of otorrhoea occurred after 24% of all tube insertions, and recurrent otorrhoea occurred in 29%. A persisting perforation developed in 19% after extrusion or removal of the tube. Other, mostly minor, complications occurred in 36% with the tube in situ and in 3% after extrusion or removal of the tube. Long-term ventilation tubes provided prolonged ventilation of the middle ear, but also resulted in a considerable number of complications. For each individual case, one should therefore determine whether the advantages of long-term ventilation tubes outweigh the possible complications in view of the available alternatives for middle ear ventilation.

Adolescent↗