Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Inhalation”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95Linked to original sources

An evaluation of total and inhalable samplers for the collection of wood dust in three wood products industries.

In 1998 the American Conference for Governmental Industrial Hygienists (ACGIH) proposed size selective sampling for wood dust based on the inhalable fraction. Thus the proposed threshold limit values (TLVs) require the use of a sampler whose performance matches the inhalable convention. The Institute of Occupational Medicine (IOM) sampler has shown good agreement with the inhalable convention under controlled conditions, and the Button sampler, developed by the University of Cincinnati, has shown reasonable agreement in at least one laboratory study. The Button sampler has not been previously evaluated under wood working conditions, and the IOM has been shown to sample more mass than expected when compared to the standard closed-face cassette, which may be due to the collection of very large particles in wood working environments. Some projectile particles may be > 100 microm aerodynamic diameter and thus outside the range of the convention. Such particles, if present, can bias the estimates of concentration considerably. This study is part of an on-going research focus into selecting the most appropriate inhalable sampler for use in these industries, and to examine the impact of TLV changes. This study compared gravimetric analyses (National Institute of Occupational Safety and Health Method 0500) of side-by-side personal samples using the Button, IOM, and 37 mm closed-face cassette (CFC) under field-use conditions. A total of 51 good sample pairs were collected from three wood products industries involved in the manufacturing of cabinets, furniture, and shutters. Paired t-tests were run on each sample pair using Statistical Package for the Social Sciences (SPSS) version 10. The IOM and the CFC measured statistically different concentrations (p < 0.0005, n = 16). The IOM and Button measured statistically different concentrations (p = 0.020, n = 12). The Button and CFC did not measure statistically different concentrations of wood dust (p = 0.098, n = 23). Sampler ratios for IOM/CFC pairs ranged from 1.19-19 (median 3.35). Sampler ratios for IOM/Button pairs ranged from 0.49-163 (median 3.15). Sampler ratios for CFC/Button pairs ranged from 0.36-27 (median 1.2). In all cases, higher ratios were associated with higher concentrations. The median relative difference between the IOM's and CFC's is in accord with prior field studies in woodworking environments, and, taken together, the data imply a conversion factor greater than the 2.5 normally applied to CFC results to approximate inhalable values, as measured by the IOM. Raising the limit values by approximately 50% appears warranted for this particular situation of inhalable wood dust measured by the IOM. The IOM/Button and CFC/Button ratios were unexpectedly low, which may be due to the exclusion of very large particles, collected by the IOM and CFC samplers. Further work is required to explain these results.

Dust↗

Inhalation of nasally derived nitric oxide modulates pulmonary function in humans.

The vasodilator gas nitric oxide (NO) is produced in the paranasal sinuses and is excreted continuously into the nasal airways of humans. This NO will normally reach the lungs with inspiration, especially during nasal breathing. We wanted to investigate the possible effects of low-dose inhalation of NO from the nasal airways on pulmonary function. The effects of nasal and oral breathing on transcutaneous oxygen tension (tcPO2) were studied in healthy subjects. Furthermore, we also investigated whether restoring low-dose NO inhalation would influence pulmonary vascular resistance index (PVRI) and arterial oxygenation (PaO2) in intubated patients who are deprived of NO produced in the nasal airways. Thus, air derived from the patient's own nose was aspirated and led into the inhalation limb of the ventilator. In six out of eight healthy subjects tcPO2 was 10% higher during periods of nasal breathing when compared with periods of oral breathing. In six out of six long-term intubated patients PaO2 increased by 18% in response to the addition of nasal air samples. PVRI was reduced by 11% in four of 12 short-term intubated patients when nasal air was added to the inhaled air. The present study demonstrates that tcPO2 increases during nasal breathing compared with oral breathing in healthy subjects. Furthermore, in intubated patients, who are deprived of self-inhalation of endogenous NO. PaO2 increases and pulmonary vascular resistance may decrease by adding NO-containing air, derived from the patient's own nose, to the inspired air. The involvement of self-inhaled NO in the regulation of pulmonary function may represent a novel physiological principle, namely that of an enzymatically produced airborne messenger. Furthermore, our findings may help to explain one biological role of the human paranasal sinuses.

Administration, Inhalation↗

Effects of nitric oxide inhalation on pulmonary gas exchange during exercise in highly trained athletes.

The pathophysiology of exercise-induced hypoxaemia in elite athletes is still unclear but several studies indicate that a diffusion limitation, which could be explained by an interstitial pulmonary oedema, is a major contributing factor. Stress failure would induce a haemodynamical interstitial oedema with inflammatory reaction and release of mediators like histamine. Histamine release was found to be correlated with the hypoxaemia in elite athletes. If stress failure is involved, inhalation of pulmonary vasodilatators such as nitric oxide during exercise in athletes should induce an inhibition of the histamine release and a reversal of the hypoxaemia. Nine male endurance-trained young athletes performed two randomized exercise tests: one without and the other with 15 p.p.m. of inhaled NO. Measurements of histamine release and arterial blood gas analysis were performed at rest and at 50, 75 and 100% VO2max. At rest, inhaled NO induced a decrease in PaO2 and an increase in (Ai-a)DO2 suggesting increased perfusion of units with low V(A)/Q. During exercise, NO inhalation suppressed the histamine release observed without NO and induced a moderation in the decrease in PaO2 and the increase in (Ai-a)DO2 observed between 75 and 100% of VO2max (P < 0.005). In conclusion, this study showed that NO inhalation inhibited exercise-induced histamine release in highly trained athletes, but we were unable to confirm the suppression of exercise-induced hypoxaemia (EIH). An unexpected result was that inhaled NO seemed to have a marked effect on arterial oxygenation in highly trained-athletes, by disturbing gas exchanges.

Administration, Inhalation↗

Responses of the bronchial and pulmonary circulations to short-term nitric oxide inhalation before and after endotoxaemia in the pig.

The physiological responses of the bronchial circulation to acute lung injury and endotoxin shock are largely unexplored territory. This study was carried out to study the responsiveness of the bronchial circulation to nitric oxide (NO) inhalation before and after endotoxaemia, in comparison with the pulmonary circulation, as well as to study changes in bronchial blood flow during endotoxaemia. Six anaesthetized pigs (pre-treated with the cortisol-synthesis inhibitor metyrapone) received an infusion of 10 microg/kg endotoxin during 2 h. Absolute bronchial blood flow was measured via an ultrasonic flow probe around the bronchial artery. The pigs received increasing doses of inhaled NO over 5 min each (0, 0.2, 2 and 20 ppm) before and after 4 h of endotoxaemia. The increase in bronchial vascular conductance during 5 min of inhalation of 20 ppm NO before endotoxin shock was significantly higher (area under curve (AUC) 474.2 +/- 84.5% change) than after endotoxin shock (AUC 118.2 +/- 40.4%, P < 0.05 Mann-Whitney U-test). The reduction of the pulmonary arterial pressure by 20 ppm NO was not different. A short rebound effect of the pulmonary arterial pressure occurred after discontinuation of inhaled NO before endotoxaemia (AUC values above baseline 54.4 +/- 19.7% change), and was virtually abolished after endotoxaemia (AUC 6.1 +/- 4.0%, P = 0.052, Mann-Whitney U-test). Our results indicate that the responsiveness of the bronchial circulation to inhalation of increasing doses of inhaled NO during endotoxin shock clearly differ from the responsiveness of the pulmonary circulation. The reduced responsiveness of the bronchial circulation is probably related to decreased driving pressure for the bronchial blood flow. The absence of the short rebound effect on pulmonary arterial pressure (PAP) after induction of shock could be related to maximum constriction of the pulmonary vessels at 4 h.

Administration, Inhalation↗

Pharmacokinetics of epimeric budesonide and fluticasone propionate after repeat dose inhalation--intersubject variability in systemic absorption from the lung.

AIMS: Pharmacokinetic variability is likely to be a significant factor contributing to the interindividual differences in dose requirements, anti-inflammatory response and side-effects with inhaled corticosteroids (ICS), but there is limited information about the disposition of ICS during regular dosing with a pressurized metered dose inhaler (pMDI). This study uses a mixed effects modelling approach to quantify and compare the interindividual variability in pharmacokinetics of epimeric budesonide (BUD) and fluticasone propionate (FP) after repeat-dose inhalation. METHODS: This pharmacokinetic substudy was part of a previously published open-label, randomised, placebo-controlled, 7-period crossover study to evaluate the short-term effects on plasma cortisol levels of inhaled BUD (400, 800, 1600 microg twice daily) and FP (375, 750, 1000 microg twice daily) via pMDI in a group of healthy male volunteers. On the fifth day of each high-dose treatment period (BUD 1600 microg twice daily and FP 1000 microg twice daily), venous blood samples were collected in nine subjects prior to the last dose and at 15 min, 30 min, 1, 2, 4, 6 and 8 h postdose for measurement of plasma drug concentrations to determine the pharmacokinetics of epimeric BUD and FP following inhalation. Non-compartmental analysis and a mixed effects model were used to characterize the disposition profiles. RESULTS: Both drugs had a rapid absorption half-life (BUD 10 min vs FP 11.3 min), but quite different elimination half-lives (BUD 2.4 h vs FP 7.8 h). Although there were intraindividual differences in the handling of the 22R-and 22S-epimers of BUD, there were no consistent pharmacokinetic differences between the two enantiomers in the group as a whole. Consistent with previous reports of FP's higher volume of distribution (V) and lower systemic bioavailability (F), the V/F ratio was lower for BUD than FP (498 l vs 8100 l). The parameter with the greatest interindividual variability for both BUD and FP was the rate of systemic absorption from the lung. CONCLUSIONS: This is the first report describing the pharmacokinetics of epimeric BUD and FP after repeat dose inhalation via pMDI. Three observations may be of clinical relevance: (1) there is considerable intersubject variability in the rate of absorption of both drugs from the lung; (2) in some individuals there was a long t(1/2),z for BUD, resulting in higher and more sustained plasma drug levels in the 4-12 h postdose period than would be predicted from single-dose pharmacokinetic data; and (3) there is evidence of diurnal variation in FP pharmacokinetics, with higher-than-expected plasma drug concentrations in the morning compared with the evening.

Administration, Inhalation↗

Inhaled procaterol inhibits histamine-induced airflow obstruction and microvascular leakage in guinea-pig airways with allergic inflammation.

BACKGROUND: Beta2-adrenoceptor agonists (beta2-agonists) are shown to inhibit airway microvascular leakage in experimental animals. This effect may change in animals with chronic airway inflammation. OBJECTIVE: We examined whether inhaled beta2-agonists inhibit microvascular leakage in guinea-pig airways with chronic allergic inflammation. METHODS: Three weeks after the sensitization with ovalbumin (OA; 6 mg/mL), each guinea pig was challenged with inhaled OA once a day for 1 or 3 weeks. Control animals without sensitization with OA also inhaled vehicle for OA (saline) for 3 weeks. One day after the last challenge, different doses of inhaled procaterol (1, 3 or 10 microg/mL) or vehicle was given to animals for 10 min after an anaesthesia. Fifteen minutes after the end of inhalation, the animals were given i.v. Evans blue dye (EB dye; 20 mg/kg), a marker of microvascular leakage, and then i.v. histamine (3 or 30 microg/kg) or vehicle. Lung resistance, a parameter of airflow obstruction, was measured for 6 min and the lungs were removed to calculate the amount of extravasated EB dye into the airways. RESULTS: A significant increase in eosinophil infiltration into the airways was seen in sensitized and challenged animals compared with control animals without sensitization. Among animals receiving antigenic exposure for either 0 (control), 1 or 3 weeks, 10 microg/mL procaterol significantly inhibited 30 microg/kg histamine-induced increase in EB dye extravasation to a similar degree (ranged from 28.7 to 69.8% inhibition) as well as that in lung resistance (more than 90% inhibition in all groups). The minimal dose of procaterol to inhibit 3 microg/kg histamine-induced microvascular leakage was not different between nonsensitized control animals and those sensitized and challenged for 3 weeks at all airway levels. CONCLUSION: Inhaled beta2-adrenoceptor agonists may be also potent in attenuating microvascular leakage even in the airways with chronic allergic inflammation.

Administration, Inhalation↗

Selective protective effects of nitric oxide inhalation on allergen-induced acute airway reactions in the pig.

BACKGROUND: Nitric oxide (NO) is thought to be an important mediator of inflammatory processes during allergic reactions in the respiratory tract. OBJECTIVE: This study was undertaken to investigate the effects of inhalation of NO on the allergen-induced acute airway reactions in the pig. METHODS: Specific pathogen-free pigs were sensitized with Ascaris suum antigen and challenged with an allergen aerosol during mechanical ventilation and anaesthesia. One group (n = 8) was treated with inhaled NO (20 ppm) which was given from 30 min before allergen challenge until the experiments were completed at 120 min after challenge. A control group (n = 8) did not receive NO (< 0.001 ppm). RESULTS: Inhalation of 20 ppm NO prevented the fall in arterial pO2/FiO2 levels that was observed in the control group (areas under the curve between 0 and 120 min were 3.7 +/- 1.4 kPa/min in NO-treated pigs vs. 15.9 +/- 3.4 in controls, P < 0.01, Mann-Whitney U-test) and it decreased baseline pulmonary arterial pressure (change from time-point - 30-0 was 3.1 +/- 5.3% in the control and - 19.9 +/- 3.5% in the NO group, P < 0.01), which in turn resulted in a lower pulmonary arterial pressure during allergen challenge. NO also caused vasodilatation in the bronchial circulation, resulting in increased bronchial vascular conductance throughout the experiment. NO inhalation caused a small, but non-significant, reduction in the allergen-induced bronchoconstrictor response, whereas histamine release, as detected in urine, was not changed. Total protein levels in bronchoalveolar lavage (BAL) fluid were significantly decreased in the NO group at 120 min after challenge compared with 45 min (373 +/- 101 microg/mL vs. 631 +/- 184, respectively, P < 0.05, Wilcoxon matched pairs test), whereas levels in the control group did not change between these two time-points (513 +/- 282 vs. 599 +/- 354, not significant). CONCLUSION: These findings indicate that NO inhalation improves ventilation/perfusion matching and causes some bronchodilatation during the allergen-induced acute airway reaction, whereas histamine release is not affected. Moreover, NO inhalation enhanced the clearance of extravasated protein in the airways, possibly through increased bronchial blood flow. Even though some protective effects were seen, this study does not support a therapeutic role for exogenous NO in acute allergic reactions.

Administration, Inhalation↗

Effect of the long-term use of inhaled corticosteroids on bone mineral density in asthmatic women.

OBJECTIVE: Inhaled corticosteroids have become a key element in the maintenance treatment of bronchial asthma. Recent studies have shown that administration of inhaled corticosteroids is associated with evidence of derangement in bone turnover. Therefore, we studied the bone mineral density (BMD) of asthmatic women receiving long-term inhaled corticosteroids and compared them with healthy individuals matched for age, sex, menopausal status and body mass index. METHODOLOGY: Thirty-two female patients with bronchial asthma, who had been using inhaled corticosteroids (beclomethasone dipropionate 750-1500 microg/day) regularly for at least 3 months, were included in the study. Bone mineral density measurements were done with dual X-ray absorptiometry in the lumbar area of the spine and the hip. Detailed laboratory examination was also done for the patients and 26 controls. RESULTS: There was a significant decrease in BMD of the patient group at the lumbar region and femur as compared with normal controls. In the patients there was a significant negative correlation between the duration of therapy, daily and cumulative doses, and BMD at the lumbar region but not BMD at the femur. CONCLUSIONS: These results indicate that long-term use of inhaled corticosteroids is associated with significant bone loss in asthmatic women and is especially related to the duration of therapy. Therefore, it is necessary to appropriately screen and give prophylactic treatment to those who are likely to develop osteoporosis from inhaled corticosteroid treatment.

Absorptiometry, Photon↗

Histamine inhalation is a specific but insensitive laboratory test for migraine.

Migraine is a subjective complaint and no laboratory test has until now been of value. The aim of the present study is to evaluate whether histamine inhalation may be used as a diagnostic test for migraine. In a double-blind study design, 15 migraineurs and 15 control subjects scored headache intensity and characteristics before, during, and in the subsequent 12 h after inhalation of increasing doses of histamine (0, 2, 4, 8, 16, 32 and 64 mg/ml). During the histamine inhalations, headaches increased dose-dependently in both groups. Eleven of the migraineurs and eight of the healthy controls experienced headaches after the inhalations. These headaches fulfilled the IHS criteria for migraine without aura in six of the migraineurs, but in none of the control subjects. Using this as a test parameter, the specificity of the test was 1, but the sensitivity was only 0.4. Our results indicate that histamine inhalation is a specific but insensitive laboratory test for migraine. Migraineurs should be informed about the risk of a migraine attack being provoked before histamine inhalation in pulmonary laboratories.

Administration, Inhalation↗

Insulin inhalation with absorption enhancer at meal-times results in almost normal postprandial insulin profiles.

BACKGROUND: Conventional insulin therapy with subcutaneous injections of regular insulin at meal-times result in plasma insulin peaks that are lower and appear later than meal related insulin peaks in healthy individuals. The present study was designed in order to evaluate the resulting insulin concentrations in peripheral blood after inhalation of micro crystalline human insulin together with an absorption enhancer [dioctyl sodium sulphosuccinate (DOSS)] via a powder inhaler. METHODS: Ten insulin dependent middle-aged non-obese diabetic patients (mean diabetes duration 21 years) were included. Blood samples for glucose and insulin were taken immediately before and 13 times, up to 300 min, after insulin inhalation. The mass median aerodynamic diameter of the particles was 3.2 microm. The inhaled insulin dose was 39 U. RESULTS: Within 5 min after the end of the 2 min inhalation procedure the mean increase of insulin was 7.0 microU ml-1, and the mean maximum concentration, 12.1 microU ml-1, was reached between 20 and 30 min. There was then a slow decline until base-line was reached after around 210 min and there were no adverse events. CONCLUSIONS: Inhalation of a mixture of 39 U of insulin and enhancer resulted in a rapid plasma insulin peak with a slow decline, similar to the normal postprandial insulin profile.

Administration, Inhalation↗

Bronchoconstrictive properties of inhaled 8-epi-PGF2alpha in healthy and heaves-susceptible horses.

The 8-epi-PGF2alpha is a marker of oxidative stress which is increased in lungs of asthmatic humans and heaves-susceptible horses. 8-Epi-PGF2alpha has also been demonstrated to be an in vitro and in vivo bronchoconstrictor in humans and rodents. We hypothesised that inhaled 8-epi-PGF2alpha was a bronchoconstrictor in healthy and heaves-susceptible horses in clinical remission. The effect on ventilatory mechanics of nebulised 8-epi-PGF2alpha was compared to that of PGF2alpha and U46619, a thromboxane A2 agonist. Pulmonary resistance (R(L)) and dynamic compliance (Cdyn) were assessed in six healthy horses and in six heaves-susceptible horses in clinical remission before (baseline) and immediately after a single inhalation challenge of 1 mg 8-epi-PGF2alpha PGF2alpha, or U46619 and placebo. R(L) and Cdyn were unchanged after inhalation of 8-epi-PGF2alpha in healthy horses. In heaves-susceptible horses, 8-epi-PGF2alpha induced a significant increase of R(L) and a significant decrease of Cdyn when compared to baseline values. Differences between R(L) and Cdyn values after 8-epi-PGF2alpha inhalation and those of placebo inhalation were not significant. Differences with healthy horses were not significant. PGF2alpha and U46619 induced a significant bronchoconstriction in healthy (R(L) and Cdyn versus baseline) and heaves-susceptible horses (R(L) and Cdyn, versus baseline and placebo), the R(L) increase in heaves-susceptible horses after PGF2alpha inhalation was significantly higher than that in healthy horses. Our results suggest that 8-epi-PGF2alpha is not a bronchoconstrictor in healthy horses, and a bronchoconstrictor far less efficient than PGF2alpha and U46619 at the same dose in heaves-susceptible horses.

15-Hydroxy-11 alpha,9 alpha-(epoxymethano)prosta-5↗

Inhaled nitric oxide inhibits the release of matrix metalloproteinase-2, but not platelet activation, during extracorporeal membrane oxygenation in adult rabbits.

BACKGROUND/PURPOSE: In neonates receiving extracorporeal membrane oxygenation (ECMO), platelet activation and dysfunction occur with the release of matrix metalloproteinase (MMP)-2, which stimulates platelet aggregation. Because inhaled nitric oxide (NO) reduces pulmonary hypertension and inhibits platelet aggregation, the authors examined the effects of inhaled NO on platelet activation induced by ECMO. METHODS: Ten adult white New Zealand rabbits were instrumented for ECMO and assigned randomly to receive either inhaled NO at 40 ppm or 30% oxygen for 1 hour before ECMO and continued for 4 hours after starting ECMO. Platelet counts, collagen-induced platelet aggregation ex vivo, plasma MMP-2, and MMP-9 activities were measured. RESULTS: (1) ECMO caused thrombocytopenia, decreased platelet aggregation, and increased plasma MMP-2 and MMP-9 activities in controls. (2) Inhaled NO inhibited platelet aggregation before ECMO but did not affect the ECMO-induced thrombocytopenia and platelet activation. (3) Inhaled NO significantly abolished the ECMO-induced increase in plasma MMP-2 but not MMP-9 activities. CONCLUSIONS: Although inhaled NO did not inhibit the platelet activation during ECMO in adult rabbits, it attenuated the increase in plasma MMP-2 activity that may be important for neonates treated with ECMO.

Administration, Inhalation↗

Inhaled nebulized adrenaline improves lung function in infants with acute bronchiolitis.

Beta2-agonists have questionable symptomatic effect in infants with acute bronchiolitis, whereas inhaled, nebulized racemic adrenaline, commonly used in Norway, appears (clinically) to be effective. Limited lung function observations during acute bronchiolitis exists, and less for assessing possible effects inhaled adrenaline. In this preliminary study, tidal flow-volume loops were measured in 16 infants with acute bronchiolitis and seven healthy controls (mean age 7.9 and 4.4 months, respectively), with repeated measurements 15 min after inhaled nebulized racemic adrenaline (4 mg diluted in 2 ml saline) in nine bronchiolitis patients. The ratio of time to reach peak tidal expiratory flow to total expiratory time (tPTEF/tE) was significantly reduced in children with acute bronchiolitis (mean, 95% CI) (0.08, 0.05-0.10) compared to controls (0.31, 0.18-0.43), with significant improvement after inhaled racemic adrenaline 0.19 (0.13-0.25), parallel with significant clinical improvement. Lung function (tPTEF/tE) was reduced in infants with acute bronchiolitis and improved significantly after inhaled racemic adrenaline. Inhaled racemic adrenaline is potentially an important alternative for treating infants with acute bronchiolitis.

Acute Disease↗

Capsaicin inhalation test for identification of sensory hyperreactivity.

BACKGROUND: Patients with upper and lower airway symptoms and with pronounced sensitivity to chemical odours, such as perfumes, flower scents and tobacco smoke, have been suggested to have sensory hyperreactivity (SHR). The symptoms have been difficult to identify with physiological measurements and the effects of various medications are doubtful. However, these patients have been found to be more sensitive to inhalation of capsaicin than healthy people. The aim of this study was to establish limit values with the capsaicin inhalation test in patients with SHR. METHODS: Ninety-five consecutive patients with upper and lower airway problems, who were admitted for allergy testing, underwent a capsaicin inhalation test with three different concentrations. The number of coughs was registered during each challenge. Score systems were used for symptoms and influence on social life of sensitivity to odours. In relation to scored symptoms, the patients were grouped as SHR or not, and compared with 73 healthy controls. RESULTS: All patients and controls coughed on capsaicin in a dose-dependent manner. Symptom score of odour sensitivity in patients was positively correlated to the response of the test. Out of 95 patients, 15 (16%) were scored to SHR. Patients with SHR reacted more to the capsaicin inhalation test than the other patients and the healthy controls. The limit values for a positive capsaicin inhalation test for the SHR were determined to be 10, 35 and 55 coughs at 0.4, 2.0 and 10 microM capsaicin, respectively. CONCLUSION: The capsaicin inhalation test well reflects the degree of airway sensitivity to chemicals and to what extent the social life is influenced. The cut-off values of the test can distinguish patients with pronounced sensitivity to odours.

Administration, Inhalation↗

Improvement of asthma therapy by a novel budesonide multidose dry powder inhaler.

The objective of the present post-marketing surveillance (PMS) was the evaluation of efficacy, tolerability and acceptance of the novel budesonide (CAS 51333-22-3) multidose dry powder inhaler (MDPI) Novopulmon 200 Novolizer. A total of 3,057 patients suffering from allergic, non-allergic or mixed bronchial asthma were included in the PMS. The study medication was administered by inhalation at a median dosage of 2 x 200 micrograms budesonide/day. In order to evaluate the efficacy of the novel budesonide MDPI, pulmonary functions (peak expiratory flow rate (PEFR) and FEV1) were measured at the start of the treatment and after 4 weeks of treatment. Severity of the following symptoms was evaluated on a four-score scale: cough, wheezing, diurnal dyspnea, nocturnal dyspnea and dyspnea on physical effort. Furthermore, the patients' satisfaction in dealing with the control mechanisms (optical, acoustic, sensory, dose counter, overdose prevention) of this innovative MDPI was assessed. Patients who already had used another inhalation system assessed the control mechanisms of the novel budesonide MDPI in comparison with their previous inhalation system (e.g. fluticasone premetered dose MDPI, non-refillable budesonide MDPI). The patients' compliance and any improvement of compliance by the control mechanisms according to physicians' assessments were evaluated. The novel budesonide MDPI was shown to lead to a decrease in the severity of symptoms. The median total symptom score (0 = no symptoms, 15 = all symptoms severe) decreased from 8 before therapy to 2 after therapy. Pulmonary function measurements supported a relief of the patients' symptoms: The median PEFR increased from 5 l/s before therapy to 6.3 l/s at the end of therapy, with a median individual increase of 1 l/s. The median FEV1 increased from 2250 ml before therapy to 2700 ml at the end of therapy, with a median individual increase of 310 ml. The majority of patients were satisfied with the control mechanisms. 97% of the patients were satisfied with the optical control mechanism, 94% with the acoustic, 78% with the sensory mechanism, 92% with the dose counter and 81% with the overdose prevention. Compliance was assessed by the physicians to be good in 84% of the patients, to be satisfactory in 14% and to be not satisfactory in 2%. An improvement in compliance by the control mechanisms of the inhaler was observed in 80% of the patients. 97% of the patients were satisfied with the control mechanisms, the optical and acoustic mechanisms were confirmed as being the most important ones. The vast majority of patients assessed the control mechanisms of the novel MDPI to be better or much better than those of a previously used inhaler (e.g. 41.2% and 52.1%, respectively, of patients who had previously used a non-refillable budesonide MDPI; 38.7% and 44.7%, respectively, of patients who had previously used a fluticasone premetered dose MDPI). Overall, the novel budesonide MDPI was shown to be efficient in the relief of asthma symptoms and improvement of lung function. The MDPI's control mechanisms were shown to be well accepted by the patients and considered by the physicians as an important contributor to an improvement of patient compliance.

Administration, Inhalation↗

[Powder inhalation systems].

Inhalation of bronchodilators and corticosteroids is the mainstay treatment for patients with obstructive lung diseases. Many dry powder inhaler devices and drug combinations are now available, and competing promotional claims can confuse both prescribers and patients. The appropriate dose of a given drug may be different for a pressurized metered dose inhaler (pMDI) and a dry powder inhaler (DPI). DPIs create aerosols by drawing air through an aliquot of dry powder. The powder contains either micronized (< 5 micro m in diameter) drug particles bound into loose aggregates, or micronized drug particles that are loosely bound to large (> 30 micro m in diameter) lactose or glucose particles. Usually, the drug particles are bound to carrier particles and are stripped form the carrier particles by the energy provided by the patientacute;s inhalation. The release of respirable particles of the drug requires inspiration at relatively high flow rates (30 - 120 L/min). Other important factors influencing aerosol generation and lung deposition are device design (resistance to airflow) and environmental conditions (humidity, temperature). Preferably, patients should employ only one type of aerosol-generating device for inhalation therapy. The technique of use varies among devices, and repeated instruction is highly advisable, to ensure that the patient uses the device appropriately. At present, DPIs are recommended for prophylactic and maintenance therapy in patients with asthma and chronic obstructive pulmonary disease, but not for patients with acute severe bronchoconstriction or children less than 5 years of age.

Administration, Inhalation↗

Meter-dosed, inhaled beclomethasone attenuates bronchoalveolar oxyradical inflammation in premature infants at risk for bronchopulmonary dysplasia.

The object of this study was to examine the hypothesis that meter-dosed, inhaled beclomethasone administered to premature infants beginning at birth in a tapering dosage schedule over the first 12 days of life attenuates bronchoalveolar lining fluid oxyradical inflammation concomitant with modulation of bronchopulmonary dysplasia. The design of this study was an unblinded, uncontrolled phase I, pilot investigation of inhaled beclomethasone primarily examining safety and administration. The setting was a tertiary care neonatal intensive care unit. Intubated, premature infants were studied longitudinally to 36 weeks corrected gestational age. Meter-dosed, inhaled beclomethasone was administered in a tapering dosage schedule over the first 12 days of life. Endotracheal tube aspirates were collected on Days 2, 4, and 6 of life and assayed for various markers of bronchoalveolar lining fluid oxyradical stress. Infants were also assessed with regards to a number of relevant clinical variables and presence or absence of bronchopulmonary dysplasia at 36 weeks corrected gestational age. Although no differences in clinical outcome were apparent in comparing nine control infants with nine beclomethasone-treated infants, bronchoalveolar lining fluid from control infants exhibited evidence of apparent phospholipid peroxidation (enhanced polyunsaturated fatty acid consumption) on Day 2 of life compared to beclomethasone-treated infants. Significant differences were noted for percent arachidonic acid, total polyunsaturated fatty acids and ratio of polyunsaturated fatty acids, to saturated fatty acids. The ratio of monohydroxyl linolenic acid to native linoleic acid (a more specific marker of lipid peroxidation) as well as myeloperoxidase activity (a marker of neutrophil oxyradical stress) tended to be higher in the control group but did not achieve statistical significance for this small subject number study. No adverse reactions related to meter-dosed, inhaled beclomethasone were noted in the treatment group; most specifically no evidence of hypothalamic-pituitary-adrenal axis suppression was noted in either control or beclomethasone-treated infants. Meter-dosed, inhaled beclomethasone in the dosage schedule utilized was safe and appeared to moderate bronchoalveolar lining fluid phospholipid peroxidation. Small numbers of infants entered into the present investigation preclude comments on clinical efficacy because of the likelihood of a statistical type 2 error. However, additional investigations of inhaled beclomethasone initiated at birth in premature infants at risk for bronchopulmonary dysplasia, enrolling larger number of subjects and perhaps a higher dosage of beclomethasone, are warranted.

Administration, Inhalation↗

Preventing bronchoconstriction in exercise-induced asthma with inhaled heparin.

BACKGROUND: We have previously reported that inhaled heparin prevents allergic bronchoconstriction in sheep and inhibits the anti-IgE-mediated release of histamine from mast cells in vitro. Since the release of such mediators has been implicated in exercise-induced asthma, we investigated whether inhaled heparin could also attenuate the bronchoconstrictor response in this disease. METHODS: On five days we studied 12 subjects with a history of exercise-induced asthma. On day 1 they underwent a standardized exercise challenge on a treadmill to document the presence of exercise-induced asthma. Minute ventilation was estimated with a calibrated respiratory inductive plethysmograph. The workload was increased until the heart rate reached 85 percent of the predicted maximal value, and was sustained for 10 minutes. The magnitude of bronchoconstriction was assessed by measuring specific airway conductance before and after the exercise. On day 2 the partial-thromboplastin time was measured in plasma obtained before and after the subjects inhaled a nebulized solution of heparin (1000 U per kilogram of body weight). On days 3 through 5 the subjects were pretreated with 4 ml of inhaled heparin (1000 U per kilogram), cromolyn sodium (20 mg), or placebo according to a single-blind, randomized, crossover design and underwent exercise challenge 45 minutes later. To exclude the possibility that heparin had any direct effect on airway smooth muscle, bronchial provocation with histamine was induced in five subjects on two further days after pretreatment with either heparin or placebo. RESULTS: Inhaled heparin and cromolyn sodium had no effect on specific airway conductance at base line, but did attenuate the exercise-induced decreases in this variable: the mean (+/- SE) maximal decrease five minutes after exercise was 9 +/- 5 percent after pretreatment with heparin, as compared with 22 +/- 5 percent after pretreatment with cromolyn and 35 +/- 2 percent after pretreatment with placebo. Heparin did not change the partial-thromboplastin time and did not modify the bronchoconstrictor response to histamine. CONCLUSIONS: Inhaled heparin prevents exercise-induced asthma without influencing histamine-induced bronchoconstriction. This non-anticoagulant action of heparin is more likely to be related to a modulation of mediator release than to a direct effect on smooth muscle.

Administration, Inhalation↗