Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Friction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95Linked to original sources

The effect of ethidium bromide on mobility of DNA fragments in agarose gel electrophoresis.

Ethidium Bromide (EtBr) is sometimes added to running buffer during the separation of DNA fragments by agarose gel electrophoresis. It is used because upon binding of the molecule to the DNA and illumination with a UV light source, the DNA banding pattern can be visualized. The mode of binding of EtBr is intercalation between the base pairs. This binding changes the charge, weight, conformation, and flexibility of the DNA molecule. Since DNA molecules are sized by their relative movement through a gel compared to a molecular weight standard, mobility measurements can be critical to size determinations. After running two identical gels, one without EtBr and one with 0.25, 0.5, 0.75 or 1.0 microgram/mL EtBr in the running buffer, the mobilities of lambda HindIII DNA fragments were compared. The mobility of DNA was always less in the gels with EtBr. Using the reptation theory equation, which describes the mobility of DNA molecules through gel, changes in frictional coefficients were calculated. It was determined that the change in frictional coefficients brought about by the addition of EtBr is directly proportional to the fraction of base pairs of a fragment bound to EtBr. This change in friction is greatest in the largest fragments, which suggests that the stiffening of the molecule by the EtBr binding is the cause for the decreased mobility.

Bacteriophage lambda↗

Protein polymer drag-tags for DNA separations by end-labeled free-solution electrophoresis.

We demonstrate the feasibility of end-labeled free-solution electrophoresis (ELFSE) separation of DNA using genetically engineered protein polymers as drag-tags. Protein polymers are promising candidates for ELFSE drag-tags because their sequences and lengths are controllable not only to generate monodisperse polymers with high frictional drag, but also to meet other drag-tag requirements for high-resolution separations by microchannel electrophoresis. A series of repetitive polypeptides was designed, expressed in Escherichia coli, and purified. By performing an end-on conjugation of the protein polymers to a fluorescently labeled DNA oligomer (22 bases) and analyzing the electrophoretic mobilities of the conjugate molecules by free-solution capillary electrophoresis (CE), effects of the size and charge of the protein polymer drag-tags were investigated. In addition, the electrophoretic behavior of bioconjugates comprising relatively long DNA fragments (108 and 208 bases) and attached to uncharged drag-tags was observed, by conjugating fluorescently labeled polymerase chain reaction (PCR) products to charge-neutral protein polymers, and analyzing via CE. We calculated the amount of friction generated by the various drag-tags, and estimated the potential read-lengths that could be obtained if these drag-tags were used for DNA sequencing in our current system. The results of these studies indicate that larger and uncharged drag-tags will have the best DNA-resolving capability for ELFSE separations, and that theoretically, up to 233 DNA bases could be sequenced using one of the protein polymer drag-tags we produced, which is electrostatically neutral with a chain length of 337 amino acids. We also show that denatured (unfolded) polypeptide chains impose much greater frictional drag per unit molecular weight than folded proteins, such as streptavidin, which has been used as a drag-tag before.

DNA↗

Transfer of bacteria between biomaterials surfaces in the operating room--an experimental study.

Bacterial adhesion to and transfer between surfaces is a complicated process. With regard to the success of biomaterials implants, studies on bacterial adhesion and transfer should not be confined to biomaterials surfaces in the human body, but also encompass surfaces in the operating room, where the origin of many biomaterials related infections is found. The purpose of this study was to quantify the transfer of Staphylococcus aureus, Staphylococcus epidermidis, and Propionibacterium acnes from one operating room material to another, while accounting for surface hydrophobicity and roughness, moistness and application of friction during transfer. The tested operating room materials were gloves, broaches (orthopaedic drills), theatre gowns, and light handles. As a possible clinical intervention method to prevent transfer, it was investigated whether dipping the gloves in a chlorhexidine splash-basin affected the viability of the transferred bacteria. Transfer (moist and without friction) was demonstrated to some extent with all bacterial strains and with every material, ranging from 17% to 71%, and was influenced by the bacterial strain, moistness of the inoculum, the application of friction, and the characteristics of both the donating and the receiving surface. Dipping the glove material in 4% or 0.4% chlorhexidine solutions killed all bacteria present, regardless of whether surfaces were dried or moist and thus prevented transfer.

Bacteria↗

Site-related variations in glycosaminoglycan content and swelling properties of bovine flexor tendon.

The presence of morphologically distinct tissues within the adult bovine deep flexor tendon presented a model which we examined for correlations between proteoglycan content and tissue swelling properties. The proximal portion which experiences only tensile forces contained low levels of glycosaminoglycan (0.2% glycosaminoglycan hexosamine as percentage of dry weight) that were evenly distributed throughout its length and thickness. Collagen accounted for 80% of tissue mass, and collagen fibers formed parallel arrays running longitudinal to the direction of tensile force. In equilibrium bulk swelling tests, the properties of proximal tissue were uniform throughout the tissue and typical of collagenous tissues in which the response to equilibration in low ionic strength buffers or acid pH is dominated by the collagen network. The anterior aspect of the distal deep flexor tendon articulates with the stiff paratendinous sheath and sesamoid bones and is subjected to compressive and frictional forces in addition to longitudinal tensile forces. Along this anterior surface and extending partially into the tendon is tissue that resembles fibrocartilage with collagen fibers organized as a random network. Greatest glycosaminoglycan hexosamine contents (2-3% of dry weight) were found in the distal surface layer, and large proteoglycans were concentrated at the site receiving direct compressive and frictional loads. Equilibrium bulk swelling tests on distal tissue showed that the articulating surface layer possessed unique material properties. Distal surface layers swelled when counter ions were washed from the tissue, whereas lowered pH had little effect on distal tissue volume. Swelling properties of distal tissue correlated directly with proteoglycan content and were similar to swelling properties of articular cartilage. These results suggest that the articulating layer of distal flexor tendon is adapted for a unique set of mechanical requirements and that an elevated proteoglycan content at the site of compressive and frictional forces contributes to meeting these functional needs.

Animals↗

Stresses in plated long-bones: the role of screw tightness and interface slipping.

Using a three-dimensional finite element model of a plated long bone, we studied the influence of screw tightness, sliding frictional interfaces, and loading magnitude on the stresses within the plated bone. The model incorporated frictional interface elements that allowed stress-free separation under tensile loading to occur between the plate and bone and between the screw heads and the plate. The applied loading stimulated both static preloads created by tightening the screws that secure the plate to the bone and physiologic loads created by activity. Initial screw tightening with plate application created regions of bone hydrostatic compressive stress that may be partly responsible for ischemia under the plate. The inclusion of frictional interfaces resulted in a nonlinear relationship between physiologic loan and bone strain that was dependent on screw tightness. This nonlinear response correlated well with the results of previous in vitro studies showing that slippage between the plate and the bone can occur at physiologic load levels. The results showed that the effect of such slippage can be at least as important as plate material, rigidity, and placement in determining the degree of stress shielding. The results also indicated that previous plated bone models that assumed tight interfaces may have overestimated the extent of mechanical stress shielding.

Biomechanical Phenomena↗

Mechanical characteristics of the stem-cement interface.

The mechanical characteristics of the interface between a metallic stem and the surrounding poly(methyl methacrylate) bone cement were determined from experimental tests and finite element analyses. Push-through-stem tests of straight and tapered titanium alloy stems, surrounded by cement columns, were performed and the resulting load-displacement behavior and strain distribution on the surface of the cement column were measured for loading, unloading, and reloading. Test geometries were modelled using nonlinear, axisymmetric, finite element analyses, which incorporated Coulomb friction elements at the titanium alloy-cement interface. Initial residual stresses, due to curing of the cement column, were modeled by thermal contraction of the cement. Good agreement was obtained between load-displacement curves and surface strains predicted from the nonlinear analysis and those obtained from experiments, when a coefficient of friction of 0.3 was assumed for the stem-cement interface. These results show that, in the absence of chemical adhesion, the load-displacement behavior of a stem-cement composite can be described completely in terms of the friction at the interface and the residual stresses normal to the interface.

Animals↗

Investigation of human hair fibers using lateral force microscopy.

Atomic force microscopy (AFM) and lateral force microscopy (LFM) were used to investigate the morphologic and surface changes associated with various surface modifications to human hair. These included extraction with a series of solvents, bleaching, and treatment with a cationic copolymer. The study assessed the ability of these techniques to distinguish the changes in surface properties, including morphology and friction coefficient, as manifested in changes brought about by the indicated surface modifications. While topographic morphology can easily be investigated with contact AFM. LFM offers an additional tool for probing the surface distribution of oils and waxes. The removal of surface lipids from the fiber surface was accomplished using soxhlet extraction with t-butanol and n-hexane, while the free internal lipids (within the fiber structure) were removed by extraction with a mixture of chloroform and methanol (70:30, v/v). In addition, the surface of hair was modified with the cationic polymer, co(vinyl pyrrolidone-methacrylamidopropyl trimethylammonium chloride [PVP/MAPTAC]), and its distribution on the surface was monitored. Ambient AFM and LFM studies of surface modified and native fibers clearly indicate that when investigated as a function of tip loading force, the different modifications result in changes of the friction coefficient, which increase in this order: native, bleached, solvent extracted, and polymer-treated hair. Friction images show surface variations that are interpreted as areas of varying lipid film coverage. In addition, topographic images of the fibers show the presence of small pores, which become increasingly prevalent upon solvent extraction.

Chloroform↗

Force Calibration in Lateral Force Microscopy.

An analysis of the contact mechanics and the forces of interaction in lateral force microscopy measurements is presented. This analysis allows for a new method of interpretation of the frictional forces, the lateral contact stiffness, and the contact shear strength. The technique was developed for the interpretation of frictional data obtained with colloidal probes, although results are presented which illustrate its ability to interpret measurements recorded with both colloidal probes and standard atomic force microscopy tips. The technique is found to compensate for the variations in the contact geometry, giving repeatable results for probes of different sizes. A critical review of other techniques which have been employed to interpret the frictional force in lateral force microscopy is also presented. Copyright 2000 Academic Press.

Journal Article↗

Responses of intra-abdominal pressure and abdominal muscle activity during dynamic trunk loading in man.

The purpose of this study was to determine and compare interactions between the abdominal musculature and intra-abdominal pressure (IAP) during controlled dynamic and static trunk muscle loading. Myoelectric activity was recorded in six subjects from the rectus abdominis, obliquus externus, obliquus internus, transversus abdominis and erector spinae muscles using surface and intra-muscular fine-wire electrodes. The IAP was recorded intra-gastrically. Trunk flexions and extensions were performed lying on one side on a swivel table. An adjustable brake provided different friction loading conditions, while adding weights to an unbraked swivel table afforded various levels of inertial loading. During trunk extensions at all friction loads, IAP was elevated (1.8-7.2 kPa) with concomitant activity in transversus abdominis and obliquus internus muscles--little or no activity was seen from rectus abdominis and obliquus externus muscles. For inertia loading during trunk extension, IAP levels were somewhat lower (1.8-5.6 kPa) and displayed a second peak when abdominal muscle activity occurred in the course of decelerating the movement. For single trunk flexions with friction loading, IAP was higher than that seen in extension conditions and increased with added resistance. For inertial loading during trunk flexion, IAP showed two peaks, the larger first peak matched peak forward acceleration and general abdominal muscle activation, while the second corresponded to peak deceleration and was accompanied by activity in transversus abdominis and erector spinae muscles. It was apparent that different loading strategies produced markedly different patterns of response in both trunk musculature and intra-abdominal pressure.

Abdomen↗

Factors influencing the force control during precision grip.

A small object was gripped between the tips of the index finger and thumb and held stationary in space. Its weight and surface structure could be changed between consecutive lifting trials, without changing its visual appearance. The grip force and the vertical lifting force acting on the object, as well as the vertical position of the object were continuously recorded. Likewise, the minimal grip force necessary to prevent slipping, was measured. The difference between this minimal force and the employed grip force, was defined as the safety margin to prevent slipping. It was found that the applied grip force was critically balanced to optimize the motor behaviour so that slipping between the skin and the gripped object did not occur and the grip force did not reach exceedingly high values. To achieve this motor control, the nervous system relied on a mechanism that measured the frictional condition between the surface structure of the object and the fingers. Experiments with local anaesthesia indicated that this mechanism used information from receptors in the fingers, most likely skin mechanoreceptors. In addition to friction, the control of the grip force was heavily influenced by the weight of the object and by a safety margin factor related to the individual subject. The frictional conditions during the previous trial could also, to some extent, influence the grip force.

Adolescent↗

The relationship between maximal power and maximal torque-velocity using an electronic ergometer.

Eight subjects performed a single allout sprint on a cycle ergometer with strain gauges bonded to the cranks. The crank angle-torque curves of the left and right legs were recorded during ten revolutions using the software package supplied with the ergometer. Torque data were stored every 2 degrees (180 angletorque data per pedal revolution for each leg). The ergometer was used in the linear mode with the lowest available linear factor (F1 = 0.01). In this mode, the braking torque (TB) was proportional to cycling velocity v(TB = F1v) and mechanical power was equal to F1v2. The relationship between the torque averaged over one revolution and the average velocity of one pedal revolution was studied during the acceleration phase of short allout exercise on an electronic ergometer (eight subjects) and a friction-loaded ergometer (four subjects). The present study showed that it is possible to determine the maximal torque-velocity relationship and to calculate maximal anaerobic power during a single allout sprint using an electronic cycle ergometer provided that strain gauges are bonded to the cranks. The torque-velocity relationships calculated were linear as for a friction loaded ergometer. As expected, the values of torque and maximal power measured with the strain gauges were higher than the corresponding values computed from the data collected during an allout test on a friction loaded ergometer. The torque-angle data collected during a single allout cycling exercise would suggest that angular accelerations of the leg segments and gravitational forces play the main role at high velocity.

Adult↗

Optimal velocity for maximal power production in non-isokinetic cycling is related to muscle fibre type composition.

To determine whether power-velocity relationships obtained on a nonisokinetic cycle ergometer could be related to muscle fibre type composition, ten healthy specifically trained subjects (eight men and two women) performed brief periods of maximal cycling on a friction loaded cycle ergometer. Frictional force and flywheel velocity were recorded at a sampling frequency of 200 Hz. Power output was computed as the product of velocity and inertial plus frictional forces. Force, velocity and power were averaged over each down stroke. Muscle fibre content was determined by biopsy of the vastus lateralis muscle. Maximal down stroke power [14.36 (SD 2.37)W.kg-1] and velocity at maximal power [120 (SD 8) rpm] were in accordance with previous results obtained on an isokinetic cycle ergometer. The proportion of fast twitch fibres expressed in terms of cross sectional area was related to optimal velocity (r = 0.88, P < 0.001), to squat jump performance (r = 0.78, P < 0.01) and tended to be related to maximal power expressed per kilogram of body mass (r = 0.60, P = 0.06). Squat jump performance was also related to cycling maximal power. expressed per kilogram of body mass (r = 0.87, P < 0.01) and to optimal velocity (r = 0.86, P < 0.01). All these data suggest that the nonisokinetic cycle ergometer is a good tool with which to evaluate the relative contribution of type II fibres to maximal power output. Furthermore, the strong correlation obtained demonstrated that optimal velocity, when related to training status, would appear to be the most accurate parameter to explore the fibre composition of the knee extensor muscle.

Adult↗

[The deactivation behavior and effectiveness of different orthodontic leveling arches--a dynamic analysis of the force systems].

Using the orthodontic measuring and simulation system (OMSS), the deactivation behaviour of diverse orthodontic levelling arches was investigated. The vertical forces and uprighting moments, as also the levelling effectiveness for initial malalignments of tooth 21 (1 mm and 2 mm infraocclusion, 20 degrees angulation) were measured, with the influence of various ligatures used in clinical practice being taken into account. The results may be summarized as follows: In the case of a large vertical offset (infraocclusion) the vertical forces can attain values of up to 3.8 N, depending on the type of levelling arch used. On deactivation, we can observe a sharp decrease in force caused by the frictional resistance between bracket and arch wire, which has to be overcome by the wire. The loss of desired force caused by friction may be as much as 50%, and is determined by the arch wire, bracket and mode of ligation. A smaller vertical offset (infraocclusion) (1 mm) is associated with extrusive forces of 0.2 N--0.8 N. Using looped levelling arches made of 0.016" standard steel wire, there is no frictional loss of orthodontic force, so that the highest vertical forces (more than 3.0 N) are observed with these arch wires. With an initial angulation of the tooth of about 20 degrees, uprighting moments of between 3.0 Nmm and 33.0 Nmm are measured, the looped arches again generating the highest moments. To ensure adequate uprighting moments in a combination of vertical offset (infraocclusion) and angulation, very high extrusive forces must be accepted. As a dynamic analysis of the tooth movement with the OMSS shows, the use of a specific arch wire results in a typical levelling defect. There is no general correlation between extrusive force or uprighting moment and the levelling effectiveness of an orthodontic arch. It is not possible to recommend a particular levelling arch.

Biomechanical Phenomena↗

Optical acceleration cancellation: a viable interception strategy?

Interception of fly balls requires active locomotion toward the point where catching can take place; as a result, the visual information guiding interception is affected by the catcher's own movement. The only interception theory currently available for a catcher standing in the plane of motion of the ball is Optical Acceleration Cancellation (OAC); in this strategy, the pseudo-optical variable "optical acceleration" (OA), if nonzero, specifies how the catcher should adjust his current velocity. We formulate a precise implementation of OAC where the catcher strives to maintain OA zero at all times and analyze its implications in terms of the catcher's interception behavior for different ball trajectories under air-friction-free, low-friction, and friction-dominated conditions. We conclude that the point in the ball trajectory where first visual contact (FVC) takes place determines to a large extent the ensuing interception behavior of the catcher. Conventional trajectories (FVC slightly above eye level, ball coming toward the catcher) result in fast acceleration to a constant velocity and successful interception. Trajectories with FVC below eye level typically result in unsatisfactory behavior of the catcher, who runs away from rather than toward the point of interception. In addition, ball trajectories are identified for which the OA equals zero even though the catcher is not on an interception course.

Acceleration↗

Driver behaviour at horizontal curves: risk compensation and the margin of safety.

A study involving unobtrusive observation of drivers at horizontal curves before and after realignment is described. The speeds and path radii adopted by drivers in the curves before and after realignment are compared, as are the levels of side friction demanded by each driver while negotiating the curves before and after realignment. The results reveal substantial variations between drivers (with respect to speed, path radius, and side friction demand) and between the path and curve radii. While vehicle speeds increased markedly, the side friction demand was reduced for all curves except one. It is concluded that the margin of safety was increased for all curves, and this is supported by the accident data.

Automobile Driving↗

Frequency of pericardial effusion as determined by M-mode echocardiography in acute myocardial infarction.

A pericardial friction rub occurs in 6 to 16% of patients after acute myocardial infarction (AMI), but the incidence of pericardial effusion (PE) is not known. M-mode echocardiography was done 1, 3 and 5 days after AMI in 43 consecutive patients admitted within 24 hours of AMI, and PE was detected in 16 (37%). The PE was small in 7 patients, moderate in 6 and large in 3. A pericardial friction rub developed in 8 (19%), of whom only 4 had PE. Pleuritic chest pain diminished by sitting up and relieved by antiinflammatory agents developed in 12 (28%), of whom only 5 had PE. The peak creatine kinase level was significantly higher in patients with PE (1,769 +/- 1,003 U) than in those without (1,181 +/- 838 units). More patients with PE were in Killip classification II, III or IV (11 of 16 [69%] vs 9 of 27 [33%]). The presence of PE was not associated with age, site of AMI, development of Q waves, use of heparin or previous AMI. In conclusion, PE as detected by M-mode echocardiography is frequently present after AMI, and its presence is not closely associated with the occurrence of a pericardial friction rub or typical pericardial pain.

Aged↗

Suture technic and suture-holding capacity. A model study and a theoretical analysis.

The suture-holding capacity (SHC) of six representative surgical suture materials was analyzed. The single loop, the far-and-near, and the near-and-near suture technics were used in the study. The SHC was found to depend on: (1) the coefficient of friction between the suture strand and the tissue; (2) the distensibility of tied and untied fiber; (3) the holding capacity of the knot used; and (4) the strength of the untied strand. Knot-holding capacity (KHC) was of the greatest importance when the single loop technic was used and when the friction between the suture strand and the tissue was low. When the near-and-near or the far-and-near technic was used, the SHC was influenced little by the strength of the knot, especially when the coefficient of friction between strand and tissue was high. The near-and-near suture technic produced the strongest sutures for all materials except Dexon, for which the far-and-near technic produced the strongest sutures. With a correct suture and tying technic, one can optimally use the strength of the suture material and one can use thin strands.

Humans↗

Linear and nonlinear one-dimensional models of pulse wave transmission at high Womersley numbers.

The accuracy of nonlinear and linear one-dimensional models in describing pulse wave propagation in a uniform cylindrical viscoelastic tube, with Womersley's parameter alpha equal to 7.6 at 1 Hz, was evaluated. To this end calculations of wave propagation using these models were compared with the experimentally determined propagation of the pressure wave in the tube. The experimentally generated pressure pulse had an amplitude of 9.0 kPa and caused a relative radius change of about 17%. The static pressure vs cross-sectional area relation was found to be nonlinear for these pressure changes. Maximum fluid velocity was about 2.9 ms-1, while the phase velocity was about 5.4 ms-1. The radius change and the ratio of fluid and phase velocities violated the linear model assumptions. The nonlinear model with viscous fluid friction modelled on the basis of Poiseuille's law and treating the tube wall as purely elastic, underestimated the damping of the pulse wave and predicted the formation of shock waves, which were not found experimentally. In the linear models, the viscous friction of the blood was modelled according to either Poiseuille's law or Womersley's theory and the tube wall was treated as either linearly elastic or linearly viscoelastic. A description of the viscous friction of the blood based on Poiseuille's law underestimated damping. Disregarding the viscoelasticity of the tube wall resulted in an underestimation of both phase velocity and damping. In spite of the nonlinearity of the system, the linear viscoelastic Womersley model described the pulse wave propagation satisfactorily.

Animals↗