Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Fractures, Compression”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95Linked to original sources

Treatment of mandibular angle fractures using two mini dynamic compression plates.

Thirty patients with 31 fractures of the mandibular angle were treated by open reduction and internal fixation using two mini dynamic compression plates with self-threading screws placed through a transoral incision with transbuccal trochar instrumentation. None of the patients were placed into postsurgical maxillomandibular fixation (MMF) or training elastics. Complications requiring secondary surgical intervention occurred in nine fractures (29%). Three were early infections requiring incision and drainage, removal of the hardware, and postoperative MMF. One was a nonunion with malocclusion requiring application of a more rigid bone plate. Five fractures developed late chronic swelling and low-grade infection requiring plate removal. Osseous union had occurred in these cases and no MMF was necessary. The use of two mini dynamic compression plates in the manner done in this study was found to be a relatively easy but unpredictable treatment for fractures of the mandibular angle.

Adolescent↗

Percutaneous compression plating for intertrochanteric fractures. Surgical technique, tips for surgery, and results.

OBJECTIVE: Fixation of intertrochanteric fractures by a minimally invasive technique using the Percutaneous Compression Plate (PCCP) allowing anatomic reduction and immediate postoperative weight bearing. INDICATIONS: Intertrochanteric fractures. CONTRAINDICATIONS: Intertrochanteric fractures that cannot be reduced by closed manipulation, subtrochanteric and reverse oblique fractures (AO/OTA 31-A3). SURGICAL TECHNIQUE: Placement of patient on a fracture table with a posterior reduction device (PORD) supporting the fracture. Reduction of the fracture by closed manipulation. Percutaneous insertion of the plate through a lateral proximal incision. Adaptation of the plate to the lateral aspect of the proximal femoral shaft with a bone clamp inserted through a second, more distal incision. Insertion of telescoping compression neck screw through the plate into the neck and securing of plate to the femoral shaft with three additional screws. Finally, completion of fracture fixation with second neck screw. RESULTS: Of 130 patients with intertrochanteric fractures treated using the described technique at the Orthopedic Surgery Department Hadassah University Hospital, Jerusalem, Israel, between May 2000 and December 2001, 108 were available for this study. Patients' age averaged 81 years (+/- 8 years). Mean surgical time was 67 min and mean hospital stay 11.5 days. 40% of patients did not require a transfusion during hospitalization, while 8.3% needed more than three units of packed cells. Complications occurred in four patients: two implant failures that were successfully revised with a Compression Hip Screw, one nonunion treated with hip arthroplasty; the fourth patient had a shortening of 3 cm needing a heel lift. Three patients developed an infection, one requiring surgical debridement.

Aged↗

Treatment of femoral neck fractures with a sliding compression screw and two Knowles pins.

Twenty-one patients with an average age of 65 years had displaced femoral neck fractures treated by a sliding compression screw and two Knowles pins. All patients had either Garden III or Garden IV fractures. One patient healed with a malunion and five developed symptomatic avascular necrosis; all of these patients required reconstructive surgery. There were no nonunions. The sliding compression screw with two Knowles pins gave a 100% rate of union, which was superior to most fixation methods. The incidence of avascular necrosis was 24%, the expected range for displaced femoral neck fractures.

Aged↗

Compression-plate fixation of femoral shaft fractures in children aged 8 to 12 years.

Twenty-one patients between the ages of 8 and 12 years with 23 femoral-shaft fractures underwent dynamic compression plating (DCP) between August 1993 and February 1996. Eleven patients had isolated femoral-shaft fractures, five had associated long-bone injuries, and five had multiple organ injuries. A 4.5-mm DCP plate was used in each case. Patients were kept non-weight bearing with crutches for an average of 8 weeks. Hardware failure occurred in two patients at 6 weeks. One was treated with revision plating, and the other, with spica casting. Both healed uneventfully. No other complications occurred. All patients were radiographically and clinically healed at last follow-up.

Bone Plates↗

Evaluation of surgical repair of humeral condylar fractures using self-compressing orthofix pins in 23 dogs.

OBJECTIVE: To report short- and long-term clinical and radiographic outcomes in dogs with humeral condylar fractures repaired using self-compressing Orthofix pins. STUDY DESIGN: Retrospective evaluation with solicited long-term clinical and radiographic evaluations. ANIMALS: Twenty-three dogs with humeral condylar fractures. METHODS: Medical records and radiographs were reviewed. Owners were asked to return dogs for long-term clinical and radiographic evaluation. RESULTS: Dogs were aged 1.5-26 months (mean+/-SD, 5.8+/-5.0 months) with 20 dogs weighing <5 kg (mean, 3.6+/-2.8 kg). Of 21 dogs with immediate post-operative radiographs, 10 had anatomic reduction with the rest having either a step and/or gap at the articular surface. Kirschner wire migration and implant loosening were the most common post-operative complications. All fractures with adequate follow-up radiographic evaluations achieved union. Twelve of 13 dogs returned for long-term evaluation (mean, 19.0+/-18.5 months) were either sound (10 dogs) or had subtle, weight-bearing lameness (2). Fourteen dogs had radiographs >/=75 days after surgery (mean, 18.7+/-18.3 months), 8 dogs (57%) had no radiographic evidence of osteoarthritis (OA; mean OA score, 0.8; median 0), and all dogs had good or excellent limb function. CONCLUSIONS: Self-compressing Orthofix pins are suitable implants for the stabilization of humeral condylar fractures in small breed dogs. Implants were convenient and simple to use and complications were easily resolved. Dogs consistently had good long-term clinical and radiographic outcomes with no or minimal lameness and OA. CLINICAL RELEVANCE: Self-compressing Orthofix pins should be considered for the repair of humeral condylar fractures in small breed dogs.

Animals↗

Anterior fusion for rotationally unstable cervical spine fractures.

STUDY DESIGN: A retrospective analysis of 32 rotationally unstable cervical fractures treated by brace, halo vest, or posterior surgical constructs plus fusion is compared with a second, prospective study of 18 similar fractures treated by early anterior discectomy, fusion, and plating. OBJECTIVES: To characterize an often unrecognized fracture pattern and compare various methods of management to identify the most effective treatment. SUMMARY OF BACKGROUND DATA: The rotationally unstable cervical spine fracture (compression-extension Stage 1) involves a hyperextension and lateral flexion injury, resulting in a unilateral pedicle, facet complex, and/or lamina fracture under compression and anterior annular disruption under tension. This fracture pattern allows a rotatory spondylolisthesis of the spine around the axis of the intact lateral mass and facet complex. METHODS: A retrospective review was made of 284 cervical fractures, identifying 32 compression-extension Stage 1 fractures that were treated by a variety of techniques. The results of that study led to a second (prospective) study, in which 18 similar fractures were treated by early anterior discectomy, fusion, and plating. RESULTS: Nonoperative treatment was uniformly unsuccessful. Posterior stabilization and fusion procedures led to unsuccessful results in 45%, related either to late kyphosis because of disc collapse or the inability of midline stabilization procedures to control rotational instability. Anterior fusion resulted in solid union without residual deformity in all cases. All four patients in the prospective study with incomplete cord lesions showed improvement in cord function, as did seven patients who had radiculopathy. CONCLUSION: Although posterior bony injury is the usual radiographic finding, the anterior disc and anterior longitudinal ligament disruption are the more significant injuries and lead to late collapse and kyphotic deformity. Early anterior fusion is recommended in compression- extension Stage 1 cervical spine injuries.

Adolescent↗

[Vertebral compression in epilepsy. Analysis of 8 cases].

Epileptic seizures can produce dislocations or fractures of the limbs and vertebral compression fractures. We tried to determine the clinical and radiological features of the latter in 8 patients: 6 men and 2 women including one aged only 41 years. The often multiple compression fractures involved the first thoracic (n = 3) and the intermediate thoracic (n = 3) or lower lumbar (n = 2) vertebrae but, contrary to common osteoporosis, never the thoracolumbar hinge. In 2 cases, the appearance of the fracture and the neurological signs led to surgery. Posterior dislocation of the shoulder was associated with the fractures in 2 cases. Chronic alcoholism (4 cases), anti-epileptic drugs (1 case) or corticosteroids (1 case) might have facilitated a demineralization which was however not obvious on X-ray films. The seizure was a first ever event in 6 cases. In the absence of controls the fracture was considered to be spontaneous. These particularities explain why a metastatic compression fracture was initially suspected in 3 cases, leading to explorations which sometimes were aggressive. In the presence of a suspicious vertebral compression fracture the clinician must consider the possibility of an epileptic seizure, a trauma which is sufficient to explain the fracture, as shown by the complications of electro-convulsive therapy.

Adult↗

Finite-element stress analysis of the normal and osteoporotic lumbar vertebral body.

A finite-element model of an isolated elderly human L3 vertebral body was developed to study how material properties and loading conditions influence end-plate and cortical-shell displacements and stresses. The model consisted of an idealized geometric representation of an isolated vertebral body, with a 1-mm-thick end plate and cortical shell. For uniform compression, large tensile stresses occurred all around the cortical shell just below the end plate as a result of bending of the cortical shell as it supported the end plate. Large tensile bending stresses also developed in the inferior surface of the end plate. Equal reductions in both trabecular and cortical bone moduli increased displacements but did not affect peak stresses. A 50% reduction in trabecular bone modulus alone increased peak stresses in the end plate by 74%. Elimination of the cortical shell reduced peak stresses in the end plate by approximately 20%. For nonuniform, anteriorly eccentric compression, peak stresses everywhere changed by less than 11% but moved to the anterior aspect. When material properties were adjusted to represent osteoporosis with disproportionate reductions in trabecular (50% decrease) and cortical (25% decrease) bone moduli, anterior compression increased peak stresses by up to 250% compared to uniform compression. If fractures are initiated in regions of large tensile stresses, the results from this relatively simple model may explain how central end-plate and transverse fractures initiate from uniform compression of the end plate. Furthermore, for anterior compression, disproportionate modulus reductions in trabecular and cortical bone may substantially increase end plate and cortical shell stresses, suggesting a cause of age-related spine fractures.

Aged↗

Hip fractures: condylocephalic rod versus compression screw.

In a series of 70 consecutive patients with nonpathologic intertrochanteric or subtrochanteric hip fractures, the first 35 were treated by a single semi-flexible condylocephalic nail. The second 35 patients were treated by a sliding compression screw and side-plate. The groups were comparable regarding age and intercurrent medical illness. The average anesthesia time and blood loss were nearly the same in each group. The incidence of failure of fracture fixation was high in the group treated by the condylocephalic nail, statistically significant at p less than .001. None of the patients treated by the sliding compression screw and side-plate lost fracture fixation. In this series, condylocephalic nails did not provide good fixation of this type of fracture and did not lessen surgical morbidity.

Aged↗

[Locking compression plate fixation for periprosthetic femoral fracture].

OBJECTIVE: To introduce a method for fixation in periprosthetic fracture with locking compression plate (LCP). METHODS: During the surgery, a long 12-hole LCP was placed to the lateral side of the femur. Six holes of the plate were placed proximal to the main fracture line to make sure that there could be enough cortex units for rigid fixation of proximal fragments. Locking screws used except for the most proximal hole where a 4.5 mm screw was used instead. RESULTS: The patient was pain free at the fracture site one week after the surgery, and was able to walk with a cane 3 months after the surgery. Bone union was evident radiographically 3 months after the surgery. There was no loose signs around the stem. Six months after the surgery, the patient recovered full function without pain. CONCLUSION: In our experience from this case, LCP in treating periprosthetic fracture was easy and less time consuming, more over, extensive periosteal stripping could be avoided. LCP is a good choice in treating some periprosthetic fractures.

Aged↗

A biomechanical evaluation of methods of distal humerus fracture fixation using locking compression plates versus conventional reconstruction plates.

OBJECTIVES: To examine the biomechanical behavior of 2 techniques of double-plate osteosynthesis for fractures of the adult distal humerus using conventional reconstruction plates and locking compression plates. DESIGN: Basic science study. SETTING: Experimental in vitro study. PATIENTS/PARTICIPANTS: Forty fresh-frozen human distal humeri specimens. INTERVENTION: Four matched groups with 10 humeri each, median age 74 years (46-95), were created using similar bone mineral density values. Two standard configurations of double-plate osteosynthesis (dorsal or 90 degrees configuration) with either conventional reconstruction plates or locking compression plates were studied for biomechanical properties of the constructs. A fracture model with a 5-mm supracondylar osteotomy gap simulating metaphyseal comminution (AO type 13-A3.3) was used. MAIN OUTCOME MEASUREMENT: Stiffness testing of the constructs in anterior/posterior bending, torsion, and axial compression loading. Evaluation of alterations of the bone-implant interface and failure patterns under cyclic loading and strength testing. RESULTS: The study demonstrates that primary stiffness in anterior/posterior bending and torsional loading is significantly increased by using locking compression plates in a 90 degrees configuration (P < 0.05) as compared with dorsally applied plates. The differences between the different plate types are insignificant if applied in the same configuration. It is demonstrated that none of the tested implants failed under cyclic loading within the number of cycles expected for 3 months of use. The bone-implant interface is less likely to fail during strength testing with locking compression plates. CONCLUSION: The biomechanical behavior of the osteosynthesis depends more on plate configuration than plate type. Advantages of locking compression plates are only significant if compared with dorsal plate application techniques. Nevertheless, locking compression plates are helpful supplementary tools for achieving primary stable fracture fixation. This might be of considerable clinical relevance in patients with diminished bone mineral quality or in the presence of metaphyseal comminution.

Aged↗

Two times unlucky: treatment of repeated adjacent vertebral fractures following posterolateral interbody fusion.

Posterolateral interbody fusion with cages and posterior fixation is a widespread, accepted method in the treatment of lumbar instability with and without spinal stenosis. Adjacent level instability was occasionally detected in the neighbouring discs. A fracture of the adjacent vertebral body including the upper disc was not reported in the literature. The authors describe a case of a female patient with two time fractures in the adjacent levels-nontraumatic and traumatic-after posterolateral fusion. Recommendations regarding the operative treatment were given.

Aged↗

[Fat embolism of retinal arteries following acute pancreatitis].

Fat embolism is well known in traumatic skull fractures, chest compression and long bone fractures. Inkeles and Walsh (1975) first described fat embolism of retinal vessels following acute pancreatitis. Fat embolism of ocular vessels in this disease is presumably due to enzymatic destruction of omental tissue. The patient described here fell ill with acute pancreatitis after years of alcohol abuse; he noticed a considerable deterioration in vision. This was a result of fat embolism of the retinal arteries. Multiple cotton wool spots around the optic nerve and in the macular area, combined with some intraretinal hemorrhages, were seen at ophthalmoscopic examination. The pathogenesis of fat embolism of choroidal and retinal vessels following acute pancreatitis is discussed in brief.

Acute Disease↗

Percutaneous screw fixation of fractures of the iliac wing and fracture-dislocations of the sacro-iliac joint (OTA Types 61-B2.2 and 61-B2.3, or Young-Burgess "lateral compression type II" pelvic fractures).

A technique for closed reduction and percutaneous screw fixation of fractures of the iliac wing and fracture-dislocations of the sacro-iliac joint is presented. Twenty-seven pelvic fractures were treated with attempted closed reduction followed by percutaneous screw fixation. Closed reduction failed in two patients. In the other twenty-five, closed reduction to within one centimeter of residual displacement was obtained, and was followed by stabilization with percutaneously placed cannulated screws. Complications included dislodgment of a screw from the superior pubic ramus in one patient, and partial cut-out of a screw along the inner cortex of the iliac wing in another. Two patients were lost to follow-up before fracture union occurred. The remaining twenty-three patients were followed-up for an average of twenty-seven months (range, 18-48 months). All of the fractures healed in the twenty-three patients who were not lost to follow-up. All but two of the patients who were working before injury returned to work. All but one of the patients was satisfied with the outcome of their pelvic fracture treatment. Closed reduction and percutaneous screw fixation of fractures of the posterior portion of the iliac wing yields acceptable reductions, with minimal blood loss and limited damage to the surrounding soft tissues.

Adolescent↗

The role of vertebroplasty in metastatic spinal disease.

Many advances have been made in the treatment of metastatic spinal disease over the last few decades. Radiotherapy offers benefit and pain relief to many patients; however, this modality provides minimal vertebral stabilization. Surgical management consists of decompression and complex fusions. Vertebroplasty offers an adjuvant therapy to both radiotherapy and surgery by providing additional stabilization and pain relief. The results of case studies suggest that including vertebroplasty in the management of these patients is beneficial. In this article the authors review the role of vertebroplasty in metastatic spinal disease.

Bone Cements↗

Intraspinal leakage of bone cement after vertebroplasty: a report of 3 cases.

We report 3 cases of vertebroplasty-induced intraspinal leakage of bone cement that were referred to us for management. Two patients received decompressive surgery, and one received rehabilitation. The gross surgical finding of yellowish dura mater and intradural fibrosis, adhesion, and microscopic finding of arachnoid membrane fibrosis are suggestive of late effect of thermal injury. These patients had residual lower extremity weakness and urinary and stool problems 13 months, 3 years, and 4.75 years post-vertebroplasty, respectively.

Aged↗

Instability and femoral head vitality in fractures of the femoral neck.

Sixteen patients with femoral neck fractures were studied with roentgen-stereophotogrammetric analysis (RSA) and low-field magnetic resonance (MR) imaging in addition to plain roentgenography. In six patients, these results were compared with the results of histopathologic analyses. All fractures were stabilized with two cannulated titanium screws. Evaluation of fracture movement before weight bearing (nine fractures) revealed no or only slight movement (less than 3.4 mm or 4.7 degrees). During weight bearing, two undisplaced fractures were compressed about 5 mm and one 20.3 mm, because of delayed union, which was verified by repeated RSA measurements and MR imaging. The average compression in nine displaced fractures that subsequently healed was 13.3 mm. MR imaging revealed signs of femoral head necrosis in three healed and two unhealed fractures. Segmental or total femoral head necrosis was histologically confirmed in all removed femoral heads, and the fracture areas were shown to be bridged by bone trabeculae to a varying degree. Absence of micromovement six months after fracture implied uncomplicated healing. Fracture stabilization at nine to 12 months postfracture was associated with femoral head necrosis or delayed union in four of six cases. Micromotion after more than one year indicated femoral head necrosis or pseudarthrosis.

Aged↗