Dependence of radiochromic film optical density post-exposure kinetics on dose and dose fractionation.

Radiochromic film (RCF) has been shown to be a precise and accurate secondary planar dosimeter for acute exposure radiation fields. However, its application to low dose-rate brachytherapy has been questioned because of possible dose-rate effects. To address this concern, we have measured the optical density (OD) of Model 55-2 RCF as a function of time (interval between the completion of irradiation and densitometry using a 633 nm laser scanner) following exposure (from less than 1 hour to 90 days) for single and split doses from 1 Gy to 100 Gy. Our work demonstrates that film darkening as a function of post-irradiation time depends significantly on total dose, with films exposed to lower doses developing faster than films given higher doses. At 1 Gy, the OD 90 days after exposure is 200% larger than that measured 1 h after exposure compared to a 20% increase over 90 days for doses larger than 20 Gy. An empirical model with time-independent, fast and slow growth terms was used to fit single exposure data. The dependence of the resulting best-fit parameters on dose was investigated. Splitting the dose into two fractions (20 Gy followed by doses of 1-80 Gy 24 h later) results in modest post-irradiation time-dependent changes in the total optical density (at most 15% at small doses), which dissipates within 20 hours following the second exposure. This experimental finding is consistent with the predictions of a simple cumulative dose superposition model. Overall, both experimental and empirical modeling suggest that dose-rate effects may be relatively small despite the strong dependence of film darkening kinetics on total dose. However, more experimental evaluation of radiochromic film response dependence on dose rate and dose-time-fractionation patterns is needed.

Brachytherapy↗

A novel method of radiochromic film dosimetry using a color scanner.

A procedure that allows the improved extraction of the dose information based on the multicolor scanning of the radiochromic film is presented. The basic principle is the determination of the dose values from each color channel of the digital film image in RGB format by applying a nonlinear calibration function. The best estimate of the dose is then a weighted mean of the dose values derived from each color channel. The weighting factors are determined in such a way that the noise in the two-dimensional dose profile is at the minimum. The calculation of the weighting factors is presented; they are chosen to be proportional to the signal-to-noise ratio, Si/v(i)2, in all three color channels, i=red, green, or blue. The data reduction can be fully computerized, including the "cleaning" of the digital image from dust and scratches. It is highly reproducible, which is important for quality assurance, and easy to use. Our novel evaluation procedure combines the good response in the low dose range of the red color with the extended dose range of the blue and green color channels (response up to 10,000 Gy), making use of one single, steady evaluation function. Therefore, a smooth evaluation is possible in a wide dose range. For the interpretation of measurements with the radiochromic films the spatial inhomogeneity of the film's response to ionizing radiation is very important. Investigations on both film types, HS and MD55-2, as well as on the new EBT film have been carried out.

Algorithms↗

Film dosimetry of megavoltage photon beams: a practical method of isodensity-to-isodose curve conversion.

The central problems of photon beam film dosimetry are the dependence of film response upon photon energy, processing conditions, and film plane orientation. We have overcome these problems by accurately fitting the depth-dependent sensitometric curve of Kodak XV-2 film (exposed parallel to beam axis) to the equation OD(D,d) = ODs(1 - exp [- alpha 0[1 + beta(d-dm)]D]) where OD(D,d) is the optical density for dose D at depth d. ODs, alpha 0, and beta are constants characteristic of the film and beam energy but are independent of field size. Only central axis depth dose data for a single field are required to determine their values. A computer program based upon this equation has been written which successfully generates single field isodose curves from film data for a variety of field sizes (including wedged fields) with an accuracy of +/- 3%. Data are presented for 60Co, and 4 and 10 MV x rays.

Film Dosimetry↗

An electronic device for digitizing radiotherapy films for the construction of tissue compensators.

An electronic device was designed that measures film optical density and may be attached to the sonic pen of an x,y graphics terminal. Therapy portal films may be digitized by moving the assembly across the film by hand. Data is measured at a rate of 40 data points per second; hence, a large film can be digitized in about 5 min. Supporting computer software constructs a matrix array of optical densities covering the area of the film, converts optical density to dose, and plots tissue compensators. The concept of designing compensators from port films is reviewed. Phantom studies were performed to show that the compensators so designed are satisfactory for clinical application.

Models, Structural↗

Measurement of dose distributions using film in therapeutic electron beams.

The feasibility of using film dosimetry data as the input data for patient treatment planning was evaluated. The central-axis depth dose and the off-axis ratios obtained from film measurements in a solid phantom were compared with those of ion-chamber measurements in water. Two techniques were used to generate isodose distributions. The first technique used only the film data, i.e., the central-axis depth dose and the off-axis ratios used for the reconstruction were determined from the film optical density (corrected for film nonlinearity). In the second technique, the central-axis depth dose measured by an ion chamber in a water phantom was combined with the off-axis ratios measured using film in the "solid water" phantom. The resulting isodose distributions from both techniques were compared with the ion-chamber measurements in water for 7-, 12-, and 18-MeV electrons, and the second technique showed better agreement with the ion-chamber measurements than did the first technique. The differences were within a clinically acceptable range.

Electrons↗

The measurement of radiation dose profiles for electron-beam computed tomography using film dosimetry.

The unique geometry of electron-beam CT (EBCT) scanners produces radiation dose profiles with widths which can be considerably different from the corresponding nominal scan width. Additionally, EBCT scanners produce both complex (multiple-slice) and narrow (3 mm) radiation profiles. This work describes the measurement of the axial dose distribution from EBCT within a scattering phantom using film dosimetry methods, which offer increased convenience and spatial resolution compared to thermoluminescent dosimetry (TLD) techniques. Therapy localization film was cut into 8 x 220 mm strips and placed within specially constructed light-tight holders for placement within the cavities of a CT Dose Index (CTDI) phantom. The film was calibrated using a conventional overhead x-ray tube with spectral characteristics matched to the EBCT scanner (130 kVp, 10 mm A1 HVL). The films were digitized at five samples per mm and calibrated dose profiles plotted as a function of z-axis position. Errors due to angle-of-incidence and beam hardening were estimated to be less than 5% and 10%, respectively. The integral exposure under film dose profiles agreed with ion-chamber measurements to within 15%. Exposures measured along the radiation profile differed from TLD measurements by an average of 5%. The film technique provided acceptable accuracy and convenience in comparison to conventional TLD methods, and allowed high spatial-resolution measurement of EBCT radiation dose profiles.

Electrons↗

The use of radiochromic film in treatment verification of dynamic stereotactic radiosurgery.

Standard silver-based films are usually too sensitive to be used as direct indicators of dose in dynamic radiosurgery because of optical saturation. This paper describes the use of a new radiochromic film to measure 6-MV radiosurgery doses and dose distributions in a head phantom. Dose calibration of the radiochromic film was performed in the range of 2.3-50.2 Gy using light of 632- and 530-nm wavelengths. Radiosurgery dose distributions were measured using the radiochromic film in a head phantom undergoing the same treatment as a patient, and were compared with the planned distributions. For an example case (nominal 2.0-cm-diam cone), film measurement verified the calculated dose distribution in one plane. The simple measurement technique described led to experimental uncertainties of +/- 0.1 cm for the 90% and 50% isodose lines, +/- 0.3 cm for the 20% line, and +/- 0.5 cm for the 10% line. Isocenter dose was measured with an uncertainty of +/- 3%. Refinements to the technique should allow more precise measurements. It is concluded that the radiochromic film, with some limitations, is a convenient and useful tool for dynamic radiosurgery quality assurance.

Film Dosimetry↗

A filtration method for improving film dosimetry in photon radiation therapy.

Successful radiotherapy requires accurate dosimetry for treatment verification. Existing dosimeters such as ion chambers, TLD, and diodes have drawbacks such as relatively long measurement time and poor spatial resolution. These disadvantages become serious problems for dynamic-wedged beams. Thus the clinical use of dynamic wedges requires an improved dosimetry method. X-ray film may serve this purpose. However, x-ray film is not clinically accepted as a dosimeter for photon beams, because it overresponds to photons with energies below about 400 keV. This paper presents and develops a method which was initially proposed by Burch to improve the dose response of x-ray film in a phantom. The method is based on placing high-atomic number foils next to the film. The foils are used as filters to preferentially remove low-energy photons. The optimal film and filter configuration in a phantom was determined using a mathematical scheme derived in this study and a Monte Carlo technique (ITS code). The optimal configuration thus determined is as follows: the filter-to-film distance of 6 mm and the filter thickness of 0.15 mm for percent depth-dose measurement; the distance of 1 cm and the thickness of 0.25 mm for off-axis (dose) ratio measurement. The configuration was then tested with photon beams from a 4 MV linac. The test result indicates that the in-phantom dose distribution based on the optimal configuration agrees well with those measured by ion chambers.

Calibration↗

Comparison of a cathode-ray-tube and film for display of computed radiographic images.

The goal of the study was to compare a cathode-ray-tube (CRT) digital display with film by using task-dependent image quality assessment methods. Contrast-detail analysis was utilized. Human observers performed a simple detection task, specifically, detecting a pillbox target in a uniform Poisson field, using either film or a digital display that employed a CRT monitor. Observers performed equally well on both film and CRT when the window settings of the digital display were established subjectively by a radiologist. Changing the window settings of the digital display to match the average background luminance of a film-illuminator combination decreased the luminance contrast of the targets and observer performance was reduced, though these effects were probably not linked. The "gold standard" film had lower luminance contrast than the CRT displayed images, yet observer performance was never lower for film than for the CRT. Therefore we concluded that luminance contrast was not a limiting factor for observer performance in this study. The CRT monitor changed fairly rapidly after it was calibrated. During a period of six months the gamma of the display increased from 1.82 to 2.42 and the maximum luminance decreased from 319 to 228 cd/m2. Low luminance output demonstrated a larger percentage decrease (approximately equal to 85%) than high luminance output (approximately equal to 29%) over the same time period. These observations suggest that standard window settings should be reviewed from time to time to ensure that the display is used optimally. No special look-up table setup such as perceptual linearization was used.

Calibration↗

The use of improved radiochromic film for in vivo quality assurance of high dose rate brachytherapy.

GAFChromic film has become increasingly popular for radiation dosimetry. In this study we explore the use of GAFChromic film as an in vivo dosimeter for quality assurance (QA) of fractionated high dose rate 192Ir treatments. Accuracy of dose distribution is explored for the simple vaginal cylinder geometry for which the dose can be easily calculated for comparison. Source dwell times for several patients were optimized to deliver 500 cGy at 0.5 cm from the surface of the vaginal cylinder applicator using a commercial treatment planning system. GAFChromic film was taped to the vaginal cylinder applicator and was enclosed in a leak proof rubber sleeve prior to its insertion. Optical densities were measured along the film at 2 mm spacing, using a densitometer with filtered red light. Density corrections for transient film darkening effects were made and optical densities were converted to absorbed dose in cGy. In vivo patient dose distribution measured for different patients and different fractions were compared with the calculated values along the applicator surface. The variation between the calculated and measured dose was +/- 10%. the reproducibility of dose measurement for different fraction was within +/- 5%. This study demonstrates the potential usefulness of the film as an in vivo for brachytherapy QA.

Administration, Intravaginal↗

The use of radiographic film for linear accelerator stereotactic radiosurgical dosimetry.

The measurement of stereotactic radiosurgical dose distributions requires an integrating, high-resolution dosimeter capable of providing a spatial map of absorbed dose. Although radiographic film is an accessible dosimeter fulfilling these criteria, for larger radiotherapy photon fields the sensitivity of film emulsion exhibits significant dependencies on both depth in phantom and field size. We have examined the variation of film sensitivity over the ranges of depths and field sizes of interest in radiosurgery with a 6 MV photon beam. While for large (20cm x 20cm) fields the potential error in dose due to the variation of the film response with depth reaches 15%, the corresponding maximum error for a 2.5 cm diameter radiosurgical beam is 1.5%. This uncertainty was observed to be comparable in magnitude to that produced by variation in processing conditions (1.1%) and by varying the orientation of the film plane relative to the beam central axis (1.5%). The dependence of emulsion sensitivity on field size has been observed to be negligible for fields ranging in diameter from 1.0 cm to 4.0 cm. The source of the dependence of film sensitivity has been illustrated by using an EGS4 Monte Carlo simulation for large fields to illustrate significant increases in the photon spectrum below 400 keV with depth in phantom. In contrast, relative increase of this low-energy component is negligible for radiosurgical photon fields.

Dose-Response Relationship, Radiation↗

Effect of film-based versus filmless operation on the productivity of CT technologists.

PURPOSE: To determine the relative time required for a technologist to perform a computed tomographic (CT) examination in a "filmless" versus a film-based environment. MATERIALS AND METHODS: Time-motion studies were performed in 204 consecutive CT examinations. Images from 96 examinations were electronically transferred to a picture archiving and communication system (PACS) without being printed to film, and 108 were printed to film. The time required to obtain and electronically transfer the images or print the images to film and make the current and previous studies available to the radiologists for interpretation was recorded. RESULTS: The time required for a technologist to complete a CT examination was reduced by 45% with direct image transfer to the PACS compared with the time required in the film-based mode. This reduction was due to the elimination of a number of steps in the filming process, such as the printing at multiple window or level settings. CONCLUSION: The use of a PACS can result in the elimination of multiple time-intensive tasks for the CT technologist, resulting in a marked reduction in examination time. This reduction can result in increased productivity, and, hence greater cost-effectiveness with filmless operation.

Analysis of Variance↗

Beam profile analysis using GafChromic films.

GafChromic film dosimetry techniques were used to evaluate the beam profiles for each collimator of the Leksell Gamma Knife at the University of Kentucky Medical Center. At the conclusion of acceptance testing, representatives from Leksell exposed conventional films for beam profile processing and analysis in Sweden. At the same time, an inhouse technique using GafChromic films was utilized in the analysis of the beam profiles. GafChromic films were irradiated to 100 Gray to provide data in each of the three planes for each collimator size. The films were analyzed using a scanning helium-neon laser densitometer with a small aperture of 5-10 microns. The digitized density profiles were curve-fitted using a PC plotting algorithm. The curve-fitted density profiles were converted to relative dose using a standard calibration curve determined with a conventional cobalt-60 teletherapy beam. The results are in excellent agreement with the conventional film analysis reported by Leksell. The GafChromic method has proven to be an accurate and rapid method of analysis and could be easily incorporated into a quality assurance program.

Calibration↗

The influence of film processing temperature and time on mammographic image quality.

High image quality and low radiation levels are essential in mammography. This study investigates the effect of changes in processor temperatures and developing times on sensitometric findings. These findings were matched with the changes in the image quality during similar changes in the developing parameters. Temperatures ranging between 35 degrees C and 40 degrees C and developing times from 20 s and 50 s were investigated. Higher developing temperatures and increased developing times resulted in an increase in film speed and film contrast. A definite pattern of change could be demonstrated in film speed and film contrast during sensitometry. The same pattern of change could, however, not be demonstrated in the quality of phantom images under similar circumstances. The base plus fog level was not adversely affected. Sensitometric findings of film speed can be effectively used as an indicator of radiation exposure to the patient, but cannot be used to establish the developing parameters that will give the best image quality. Both these methods should be used to determine which processing variables should be used to obtain a combination of the best image with radiation as low as possible. Recommendations for optimum processing parameters are made for the films and processing chemistry investigated.

Female↗

Consistency of film optical density in mammographic screening programmes.

Maintaining a constant and appropriate mean film optical density in mammography is an essential part of quality assurance in a breast screening programme. It depends on stability in X-ray exposure controls, film supplies, intensifying screens and film processing. A programme of weekly monitoring is described which helps to trace the source of any irregular or step-wise changes in any of the relevant parameters. Its results are also used to investigate by statistical methods the degree of film optical density variation achieved in periods of several weeks of apparent general stability. Results are presented for 20 X-ray sets and a total of 32 record periods of 8-10 weeks each. The mean standard deviation for density of a single film of a Perspex block was found to be 3.5%. For processor speed index it was the same while for X-ray set variations it was less than 2%. Neither of these last two variables showed any strong correlation with block film optical density.

Breast Neoplasms↗

Measurements of exit dose profiles in 60Co beams with a conventional portal film system.

An important step in the verification of the reliability of portal films as in vivo dosemeters is the evaluation of the agreement between exit dose profiles and optical density profiles measured on the portal film. To test the possibilities of a conventional portal film system in 60Co beams suitable for head and neck irradiation, we verified the agreement between relative exit doses (measured by ionization chamber) and relative optical densities, on cubic homogeneous phantoms, on an homogeneous "step" phantom and on a cubic phantom including air and aluminium inhomogeneities. The optical density profiles were corrected with the appropriate sensitometric curves. For an homogeneous phantom 10.8 cm thick and with the film in contact with the phantom, the agreement was found to be excellent with a mean deviation of 0.8% and a maximum deviation of 1.5%. The agreement was worse when the air gap between the exit surface of the phantom and the portal film was increased (with an air gap equal to 15 cm the maximum deviation was 4%), and when the thickness of the phantom was increased (for a thickness of 14.4 cm the maximum deviation was 3.1%). The agreement was found to be acceptable for the "step" phantom too, with a mean deviation around 1% and a maximum deviation within 2% (air gap equal to zero). When air and aluminium inhomogeneities were incorporated into the phantom a maximum deviation of 6% and a mean deviation less than 3% were found. Furthermore, the relative optical density profiles show an underestimate of measured off-axis exit dose values under a high density inhomogeneity and a small overestimate under a low density inhomogeneity. Results suggest the possibility of using conventional portal films for exit relative dosimetry in head and neck irradiation with 60Co beams if the air gap is kept as small as possible.

Air↗

Detection of approximal caries with a storage phosphor system. A comparison of enhanced digital images with dental X-ray film.

OBJECTIVES: To compare the accuracy of approximal caries detection using enhanced and unenhanced storage phosphor images and dental X-ray film. METHODS: Fifty premolar/molar teeth were exposed simultaneously under standardized conditions on storage phosphor (SP) image plates (Digora) and Ektaspeed film. The image files were transferred to a different platform for image processing. Using a five-point confidence scale, ten observers rated 95 approximal surfaces for caries in enamel and dentin with three image modalities: enhanced and unenhanced SP images and film. The observations were validated microscopically. Diagnostic accuracy was measured as the area beneath the ROC curve (Az). RESULTS: Enhanced SP images had significantly higher Az values in both enamel (Az = 0.819) and dentin (Az = 0.845) than unenhanced images and film. No significant differences were found in either enamel or dentin between unenhanced SP images (Az = 0.780 and Az = 0.789) and film (Az = 0.688 and Az = 0.793). CONCLUSION: Enhancement of storage phosphor images improved detection of approximal caries in this in vitro study compared with unenhanced images and Ektaspeed film.

Adult↗

Visually detectable resolution of intraoral dental films.

OBJECTIVES: The visually utilizable resolution of intraoral dental films was examined with the naked eye, with two-fold optical magnification and after digitization using a computer display. METHODS: Agfa Dentus M2, Kodak Ektaspeed Plus and Kodak InSight dental films were exposed with a line pair (lp) test pattern providing frequencies up to 16.6 lp mm(-1). Films were developed at 24 degrees C in a Dürr Periomat machine and at 28 degrees C in a Dürr AC245 machine. Forty dental students evaluated the maximum visually detectable resolution with their naked eye, with an X-ray viewer (providing two-fold magnifying lenses and eliminating disturbing light) and following digitization and monitor display examination. RESULTS: The best detectable resolution was achieved through digitization, reaching a mean of up to 16.5 lp mm(-1). With two-fold magnification, a mean of up to 13.3 lp mm(-1) could be resolved, while only 11.7 lp mm(-1)could be resolved with the naked eye. Unlike the other film types, the resolution of Ektaspeed depended on the processing type when viewing digitized images or when viewing with the naked eye. There was a trend for students above 29 years of age to detect a lower resolution with the naked eye, although they performed comparably with students below 29 years when using the X-ray viewer or viewing digitized images. CONCLUSIONS: Film resolution is utilized best through digitization and secondly using a magnifying lens. With the naked eye, a mean of 11 lp mm(-1) with a broad distribution can be resolved. A magnifying lens is recommended if resolution is important or if the viewer's eyesight is reduced. Compared with E-speed films, Kodak Insight was less dependent on processing conditions.

Adult↗