The effect of recent FDA legislation on contraceptive development and safety.

By law, medical devices with a potential hazard to health or safety are not subject to the same premarket approval and scientific review processes as drugs. Manufacturers of intrauterine contraceptive devices and new instruments or devices for surgical sterilization will be required to present evidence of their products' effectiveness and safety to a United States Food and drug Administration advisory panel made up of physicians and scientists from outside the agency. Hazards previously experienced with contraceptive devices and requirements for testing new devices are described.

Female↗

Vagus nerve stimulation: analysis of device parameters in 154 patients during the long-term XE5 study.

PURPOSE: To determine the effect of changes in device settings and duty cycle (on and off times) on the efficacy of vagus nerve stimulation (VNS) for refractory epilepsy. In the long-term XE5 study of VNS for intractable epilepsy, the median reduction in seizure frequency improved significantly after 1 year of follow-up. A central question is whether device changes improve efficacy. We analyzed the effects of device parameter changes on seizure frequency in 154 subjects who completed the study and who had complete data for analysis. METHODS: Retrospective analysis of device changes during the XE5 long-term study of VNS. During the XE5 long-term follow-up study, the subject's device settings were modified within a Food and Drug Administration (FDA)-approved range of output current, pulse duration, frequency, on time, and off time. Significant changes in device settings occurred after 3 months. We investigated the relationship between percentage reduction in seizures and changes in device parameters between the 3- and 12-month visits. Within-group comparisons were performed for those who continued on standard on/off cycle of 30 s on and 5 min off, and those with the most common off times of 3, 1.8, and < 1.1 min. RESULTS: Output current, pulse duration, frequency, and off time changed significantly between the 3- and 12-month long-term follow-ups. For the group as a whole, changes in device settings were not correlated with an improvement in efficacy. However, a significant improvement in efficacy occurred in a subgroup whose off time was reduced to < or = 1.1 min. In this group, the median reduction in seizures improved from 21% before the change in off time, to 39% after the change in off time (Wilcoxon Signed-Rank, p = 0.011). The responder rate (> 50% reduction in seizures) also significantly improved from 19 to 35% (McNemar's test, p = 0.046). CONCLUSIONS: The data from this retrospective analysis indicate that device changes were not the primary determinant of increased efficacy at 12 months of long-term follow-up. In general, patients who remained on the original settings of 30 s on and 5 min off continued to respond or improve in their response over the 1-year period. However, some patients may benefit from reductions in off time (increases in duty cycle). In a subgroup initially resistant to VNS, a change in off time to < or = 1.1 min off did result in significant improvements in efficacy.

Double-Blind Method↗

The nurse's role in developing voluntary consensus standards.

Involvement in evaluating and selecting products for patient care is an important function of the nurse. Invaluable aids in product evaluation are standards developed by the FDA or other standards-writing organizations, defining minimum levels of performance, labeling, and safety for specific devices. Compliance with a voluntary consensus standard, which has been approved by consensus of a committee of experts representing manufacturers and users, is recommended. Nurses should be aware of device standards and recommended practices now available or being developed for specific devices. Often the standards-writing group has developed for specific devices. Often the standards-writing group has considered or will consider specific problems troubling the nurse. Involvement in the process itself will help ensure that these problems are addressed.

Equipment Design↗

Respirator protection factors: Part II-protection factors of supplied-air respirators.

Protection Factors provided by 25 NIOSH approved supplied-air respirators were determined while the devices were worn by a panel of test subjects anthropometrically selected to represent adult facial sizes. Polydispersed DOP aerosol was used for respirator fit tests on continuous flow, demand, and pressure-demand respirators. Based on facepiece leakage measurements it appears that demand-type respirators should neither be used nor approved. The highest level of protection was provided by pressure-demand devices.

Evaluation Studies as Topic↗

Chronic evaluations of ventricular ejection phase dynamics during abdominal left ventricular assist device (ALVAD) pumping in the awake, unanesthetized calf.

In 1974, between 2 and 8% of the 50,000 adult patients undergoing cardiac surgery in this country succumbed in the early post-operative period from left ventricular failure, despite various methods of pharmacologic and/or mechanical support. Our laboratories have concentrated on the development, modification, evaluation, and validation of an abdominally positioned left ventricular assist device which has the potential of reducing these mortalities. Continuous testing in animals, for periods exceeding 2 mos, satisfied reliability, durability and longevity requirements. The cumulative results of these investigations were reviewed at the National Heart and Lung Institute on August 21, 1975. Authorization for clinical trials of the device according to specific criteria and protocols46 was approved on November 1, 1975. The ALVAD is now in the early stages of clinical testing. The results of the current experiments demonstrate that ventricular outflow impedance and prosthetic inflow impedance are the major determinants of left ventricular assist device hemodynamic effectiveness. By markedly reducing outflow impedance, the ALVAD profoundly lowers ventricular pressure-work and oxygen demands while simultaneously increasing ventricular performance and maintaining or augmenting systemic perfusion. Moreover, our studies indicate that improved device designs (intended for intermediate and long-term implantation) and maximal performance can be achieved by focusing on these central determinants.

Animals↗

Clinical results with ProDisc: European experience and U.S. investigation device exemption study.

STUDY DESIGN: This study is based on a review of the literature related to the use of the ProDisc device and a report of the preliminary results of a prospective randomized study. OBJECTIVES: To review European results related to the use of the ProDisc device and compare the results of this device to lumbar fusion in a prospective, randomized study being performed as part of a Food and Drug Administration-approved investigational study. SUMMARY OF BACKGROUND DATA: There are two devices that have been used on a large-scale basis for total disc replacement. These are the SB Charitè and the ProDisc. Both devices were created in Europe and have been used there for more than 10 years. Reported results for these devices have been favorable, but there have been no prospective studies evaluating the outcome. METHODS: The literature related to the ProDisc was reviewed. The preliminary study data were based on one center's experience participating in the Food and Drug Administration Investigation Device Exemption study. There were 39 patients with a minimum 6-month follow-up. Patients were randomly assigned to receive either the ProDisc or undergo a combined anterior-posterior lumbar fusion in a ratio of 2:1 (ProDisc to fusion). Patients completed standardized questionnaires before surgery and at 6 weeks, 3 months, and 6 months after surgery. Data collection is continuing for the 12- and 24-month follow-up. RESULTS Operative time, blood loss, and length of hospitalization were significantly less in the disc replacement group (P < 0.05). At the 3-month follow-up, the disc replacement group had a significantly greater improvement in Oswestry scores than did the fusion group. There were no differences in pain scores as measured by visual analog scales. Disc replacement patients had greater motion and there was a trend for this group to have greater satisfaction at the 6-month follow-up. CONCLUSIONS: The preliminary results of this prospective randomized study found that peri-operative factors were more favorable in the disc replacement group than in the fusion group. There was a trend to greater patient satisfaction in this group. These early results suggest that total disc replacement may be a viable alternative to lumbar spinal fusion in patients with symptomatic disc disruption unresponsive to nonoperative care. Long-term follow-up is needed and is currently being collected for this study group.

Arthroplasty, Replacement↗

Medical devices; implementation of third party review under the Food and Drug Administration Modernization Act of 1997; emergency processing request under OMB review--FDA. Notice.

The Food and Drug Administration (FDA) is announcing a program under which persons may be accredited to review premarket notifications and recommend initial classification of certain medical devices. At the same time, FDA is announcing the termination of the Third Party Review Pilot Program. This notice announces the criteria to accredit or deny accreditation to persons (Accredited Persons) who request to conduct premarket notification reviews consistent with provisions of the FDA Modernization Act of 1997 (FDAMA). FDA is also announcing that this proposed collection of information has been submitted to the Office of Management and Budget (OMB) for emergency processing under the Paperwork Reduction Act of 1995 (the PRA). FDA is requesting OMB approval within 45 days of receipt of this submission. FDA is taking this action to implement section 210 of FDAMA. The availability of guidance detailing the review of submissions, training for third party reviewers, and basic document processing by FDA is announced elsewhere in this tissue of the Federal Register.

Accreditation↗

Silicone gel-filled breast prostheses; silicone inflatable breast prostheses: patient risk information--FDA. Notice.

The Food and Drug Administration (FDA) is issuing a notice to promote the dissemination of information on risks associated with silicone gel-filled breast prostheses and silicone inflatable ("saline-filled") breast prostheses to women considering having the devices implanted. This notice addresses an important public health issue presented by the continued marketing and implantation of these unapproved devices. FDA has identified significant deficiencies in premarket approval applications for silicone gel-filled breast prostheses. FDA will regard breast prostheses as misbranded under the Federal Food, Drug, and Cosmetic Act (the act) if their labeling does not provide adequate written information to patients on the risks associated with these devices. Such information should be written so as to be easily comprehensible to most patients and should be provided to patients prior to scheduling implantation, so that patients have sufficient time to review the information and discuss it with their physicians. To satisfy the requirements of the act, such patient risk information must set out the known, suspected, and potential risks associated with implantation of these devices. This notice includes suggested patient risk information sheets as guidance.

Female↗

Ruptured abdominal aortic aneurysm after endovascular repair.

OBJECTIVE: The purpose of this study was to present the experience with aneurysm rupture after deployment of Guidant/EVT (Guidant) endografts and review previously reported cases with other devices. METHODS: Records from Guidant/EVT clinical trials and postmarket approval databases from February 1993 to August 2000 were analyzed to identify patients with rupture and to extract pertinent data. Previously reported cases were obtained with a Medline search. RESULTS: Seven ruptures were found with Guidant/EVT devices. Five of these occurred among the 686 patients in US Food and Drug Administration protocols (group I) who were followed for a mean of 41.8 +/- 21.9 months and limited to the subgroup of 93 first generation tube endografts. Two ruptures occurred in group II (3260 patients after market approval with limited follow-up), specifically in the subgroup of 166 patients who underwent treatment with second generation tube grafts. No ruptures were found in patients with bifurcation or unilateral iliac implants followed for a mean of 37.5 months. All ruptures were caused by distal aortic type I endoleaks on the basis of attachment system fractures (first generation devices only), aortic neck dilatations, persistent primary endoleaks, migration, overlooked imaging abnormalities, refused reintervention, and poor patient selection. The mortality rate was 57% (4/7) overall and was 50% for surgical repair (3/6). A literature search identified 40 additional ruptures related to other devices, for a total of 47. All 44 that were documented with adequate data were caused by endoleaks (26 type I, 2 type II, 11 type III, and 5 source not reported). Other contributing factors were graft module separation and graft wall deterioration. The overall mortality rate for the combined series was 50%, with an operative mortality rate of 41%. CONCLUSION: Postendograft AAA rupture is infrequent, although the true incidence rate is unclear because of inadequate follow-up of individual device designs. Tube endografts should be limited to the rare patient with ideal anatomy, no other alternatives, and at high risk for standard open repair. Prevention of aneurysm rupture requires long-term surveillance with attention to subtle imaging abnormalities and the establishment of reliable follow-up protocols for specific devices. The outcome of postendograft aneurysm rupture is similar to that of rupture without prior endograft therapy.

Aged↗

Medical devices manufactured from latex: European regulatory initiatives.

In Europe the marketing of medical devices manufactured from latex is regulated by directives describing the essential (safety) requirements that products have to fulfill to obtain marketing approval. This paper describes the general requirements for marketing medical devices in Europe and, more specifically, the requirements for products manufactured from natural rubber latex. The requirements for marketing medical devices can be fulfilled by using the relevant harmonized European standards. These standards are regularly under revision to incorporate the latest scientific developments. For certain devices, for example, latex medical (examination and surgical) gloves, specific standards have been published. Medical devices manufactured from latex pose a serious problem because of the risk of induction of allergy both against the latex proteins inherently present (type I or immediate type allergy) and against chemicals added during processing (type IV or delayed type hypersensitivity) present as residues in the latex products. So, besides requirements for product quality in terms of barrier properties, strength, and sterility, the main focus consists of the allergy-inducing properties of the latex products. Recent developments have reopened the discussion on the value of total protein versus allergen determination in latex medical gloves. However, as long as minimal levels needed for both sensitization and elicitation have not been established, a safe maximum level for leachable proteins/allergens in latex products cannot be determined. A European Commission guidance document on the latex allergy problem is currently being drafted by experts from Competent Authorities.

Equipment and Supplies↗

MR imaging-guided prostate biopsy with a closed MR unit at 1.5 T: initial results.

The authors evaluated a magnetic resonance (MR) imaging-compatible biopsy device comprising a needle guide that can be visualized with MR imaging and manipulated mechanically from outside the MR unit. With approval from the local ethics committee and patient consent, this device was tested in 12 patients by using a closed 1.5-T MR unit and a body phased-array coil. Patients had elevated prostate-specific antigen levels (6-60 ng/mL) and one or more areas in the prostate that were suspicious for carcinoma at prebiopsy MR imaging. Biopsy was performed with transrectal access and with the patient prone. A 16-gauge MR imaging-compatible needle was successfully positioned with the device, and between six and nine tissue cores were obtained in each patient. In one patient, two suspicious basal areas could not be reached with the device. Histologic analysis showed prostate cancer in five patients and prostatitis in six. No complications were observed. The device enabled MR imaging-guided core-needle biopsy of prostate areas suspicious for cancer on MR images.

Aged↗

Ectopic pregnancy risk when contraception fails. A review.

OBJECTIVE: To alert clinicians to the risk of ectopic pregnancy when certain contraceptive methods fail by summarizing data from trials reviewed by the U.S. Food and Drug Administration (FDA). STUDY DESIGN: The review focuses on 7 contraceptive drug products with an increased risk of ectopic pregnancy when the method fails. Data were extracted from reviews of clinical trials submitted to the FDA to support marketing applications and from the medical literature. Data on 6 other contraceptive drug products and published data for tubal ligations are used for comparison. This review does not include medroxyprogesterone acetate injections because the FDA reviews for this method did not include any pregnancy outcome information. RESULTS: The results are presented in a table and are compared to postmarketing surveillance reports and published literature, when available. The proportion of ectopic pregnancies among all pregnancies ranged from 1:2 to 1:21 for intrauterine devices, tubal ligations, progestin-only implants and progestin-only oral contraceptives. Although the confidence intervals for the proportions were large in trials with few pregnancies, both postmarketing surveillance reports and published literature support proportions calculated from clinical trial data. CONCLUSION: Pregnancies in women using progestin-only oral contraceptives, progestin-only implants, intrauterine devices and tubal ligations are more likely to be ectopic than pregnancies in the general population.

Clinical Trials as Topic↗

In vitro and in vivo studies of subcutaneous hydromorphone implants designed for the treatment of cancer pain.

Unrelieved cancer pain remains a significant problem worldwide. Patients receive inadequate analgesia for a variety of complex and multifactorial reasons. Limited availability of opioids secondary to concerns about potential diversion of these medications for illicit use and poor compliance with oral regimens are significant factors in many countries. This study was designed to develop and test an implantable opioid delivery device capable of releasing a potent opioid subcutaneously at a continuous rate for 4 weeks. A low temperature solvent casting technique was used to formulate ethylene vinyl acetate (EVA) copolymer disks containing 50% hydromorphone by weight. The release characteristics of disks of different height and diameter, coated and uncoated, and with and without a central uncoated channel were studied. The effect of temperature and pH were also evaluated. In vitro assessments were conducted in phosphate buffer using UV spectrophotometry. In vivo studies employed New Zealand White Rabbits and a radioimmunoassay. Plasma levels following hydromorphone delivery by polymer, osmotic pump, and intravenous administration were compared. In vitro, uncoated EVA polymer disks measuring 1.05 cm in diameter and 0.27 cm in height released an initial large burst of hydromorphone. Coating the disks with 100-200 microM of poly(methyl-methacrylate) prevented drug egress from the polymer. A central uncoated channel measuring 1.25 mm in diameter in an otherwise coated polymer virtually eliminated the initial burst of drug release and provided near zero-order hydromorphone release at an average rate of 164 micrograms per hour for 4 weeks. Doubling the height of the polymer approximately doubled the release rate while doubling the diameter of the polymer extended the duration of drug release to over 8 weeks. In rabbits, stable plasma hydromorphone concentrations (23-37 ng/ml) were sustained for 4 weeks following implantation of 2 polymers with an uncoated central channel. No initial burst of hydromorphone release was noted. Increasing the number of polymers produced sustained and predictable increases in plasma hydromorphone concentrations. Plasma levels were similar with subcutaneous hydromorphone delivered by polymer and osmotic pump and much less variable than with intravenous bolus hydromorphone. A uniquely configured implantable drug delivery device has been developed using materials which are approved for human use. It safely and reproducibly releases hydromorphone for weeks in vitro and in vivo without an initial burst of drug release. Varying the thickness, diameter, and number of implants provides flexibility in the release rate and duration of release. This implantable opioid delivery device could provide a sustained subcutaneous infusion of hydromorphone to patient with cancer pain in developed and developing nations without pumps, catheters, or extensive outpatient support services. In addition, it should improve compliance and reduce concern regarding illicit diversion of opioids.

Analgesics, Opioid↗

Add-on device for stereotactic core-needle breast biopsy: how many biopsy specimens are needed for a reliable diagnosis?

PURPOSE: To prospectively determine whether there is a minimum number of cores required for histopathologic diagnosis of mammographically detected nonpalpable breast lesions with an add-on 14-gauge stereotactic core-needle biopsy device. MATERIALS AND METHODS: The study was approved by the ethics committee of the hospital; informed consent was obtained. Biopsy was performed in 197 patients with 205 lesions (97 masses, 108 microcalcifications). The first sample (from the center) was collected in container A; second and third samples (2 mm from center), in container B; and additional samples, in container C. Malignancies, atypical ductal hyperplasia (ADH), and radial scars were excised. Benign lesions were followed up mammographically (mean, 24 months). Strict sensitivity and working sensitivity were calculated separately. Stereotactic biopsy with diagnosis of a nonmalignant lesion that, after surgery, proved to be malignant was considered false-negative when strict sensitivity was calculated. Stereotactic biopsy with diagnosis of ADH or radial scar was considered true-positive if the findings at surgery corresponded to the results at biopsy or indicated malignancy and was considered false-positive if the findings at surgery were benign when working sensitivity was calculated. Sensitivity, specificity, and overall accuracy of stereotactic biopsy were determined for masses and microcalcifications in all three containers by using surgical samples and findings at mammographic follow-up as reference. At chi2 analysis, P < .05 was considered to indicate significant difference. RESULTS: Strict sensitivity of the first sample was 77% (66 of 86) (90% [35 of 39] for masses, 66% [31 of 47] for microcalcifications). Results of the first sample were false-negative significantly more often in microcalcifications (n = 16) than in masses (n = 4) (P = .010). Combined results of containers A and B (ie, three samples) yielded higher strict sensitivity than those with first sample alone (95% [37 of 39] for masses [P = .196], 91% [43 of 47] for microcalcifications [P < .001]). With multiple samples, strict and working sensitivity were both 100% (39 of 39) for masses and 91% (43 of 47) and 98% (46 of 47), respectively, for microcalcifications. Four false-negative diagnoses (ADH, three cases; lesion with discordant mammographic and stereotactic biopsy findings, one case) were microcalcifications. CONCLUSION: More than three samples are needed (a minimum number was not determined) for a histologic diagnosis of a mass lesion by using an add-on stereotactic biopsy device.

Biopsy, Needle↗

The status of failure and reliability testing of artificial blood pumps.

Artificial blood pumps are today's most promising bridge-to-transplant, bridge-to-recovery, and destination therapy solutions for patients with congestive heart failure. There is a critical need for increased reliability and safety as the next generation of artificial blood pumps approach final development for long-term destination therapy. To date, extensive failure and reliability studies of these devices are considered intellectual property and thus remain unpublished. Presently, the Novacor N100PC, Thoratec VAD, and HeartMate LVAS (IP and XVE) comprise the only four artificial blood pumps commercially available for the treatment of congestive heart failure in the United States. The CardioWest TAH recently received premarket approval from the US Food and Drug Administration. With investigational device exemptions, the AB-180, AbioCor, LionHeart, DeBakey, and Flowmaker are approved for clinical testing. Other blood pumps, such as the American BioMed-Baylor TAH, CorAide, Cleveland Clinic-Nimbus TAH, HeartMate III, Hemadyne, and MagScrew TAH are currently in various stages of mock loop and animal testing, as indicated in published literature. This article extensively reviews in vitro testing, in vivo testing, and the early clinical testing of artificial blood pumps in the United States, as it relates to failure and reliability. This detailed literature review has not been published before and provides a thorough documentation of available data and testing procedures regarding failure and reliability of these various pumps.

Clinical Trials as Topic↗

Use of genetic toxicology information for risk assessment.

Genetic toxicology data are used worldwide in regulatory decision-making. On the 25th anniversary of Environmental and Molecular Mutagenesis, we think it is important to provide a brief overview of the currently available genetic toxicity tests and to outline a framework for conducting weight-of-the-evidence (WOE) evaluations that optimize the utility of genetic toxicology information for risk assessment. There are two major types of regulatory decisions made by agencies such as the Environmental Protection Agency (EPA) and the Food and Drug Administration (FDA): (1) the approval and registration of pesticides, pharmaceuticals, medical devices, and medical-use products, and (2) the setting of standards for acceptable exposure levels in air, water, and food. Genetic toxicology data are utilized for both of these regulatory decisions. The current default assumption for regulatory decisions is that chemicals that are shown to be genotoxic in standard tests are, in fact, capable of causing mutations in humans (in somatic and/or germ cells) and that they contribute to adverse health outcomes via a "genotoxic/mutagenic" mode of action (MOA). The new EPA Guidelines for Carcinogen Risk Assessment [Guidelines for Carcinogen Risk Assessment, USEPA, 2005, EPA Publication No. EPA/630/P-03/001F] emphasize the use of MOA information in risk assessment and provide a framework to help identify a possible mutagenic and/or nonmutagenic MOA for potential adverse effects. An analysis of the available genetic toxicity data is now, more than ever, a key component to consider in the derivation of an MOA for characterizing observed adverse health outcomes such as cancer. We provide our perspective and a two-step strategy for evaluating genotoxicity data for optimal use in regulatory decision-making. The strategy includes integration of all available information and provides, first, for a WOE analysis as to whether a chemical is a mutagen, and second, whether an adverse health outcome is mediated via a mutagenic MOA.

Animals↗

The use of ultrasound in the assessment of bone status.

The assessment of skeletal status has wide clinical applications, especially in the management of osteoporosis. Osteoporosis, once thought of as an unpreventable and untreatable aging process, has revealed many of its secrets over the last decade, and the advent of successful drug therapy has changed our perception of the disease. Non-invasive techniques play a fundamental role in the diagnosis of osteoporosis and in the assessment of the efficacy of drug treatments. The primary technique used in osteoporosis is dual X-ray absorptiometry (DXA), that has been established as a reliable means of measuring bone density. Quantitative ultrasound (QUS), because of the relative portability of the equipment, ease of use, lack of ionizing radiation and low cost, has great potential for widespread use. Five devices for QUS assessment have recently been approved by the Food and Drug Administration and many more applications are in progress. QUS is a relatively new technology, at least in its application to bone fragility. Nevertheless, QUS has demonstrated that it is able to detect bone fragility as well as DXA. However, diagnosis of osteoporosis by QUS remains contentious, but the problems are due more to the limitations of the present T-scores rather than to the technique. A better option for QUS would be to report results in terms of remaining lifetime fracture risk, keeping in mind that a risk estimate needs not only the QUS or DXA measurement, but also the specific data, such as age, weight, gender, hormonal status and fracture history of the patient.

Bone Density↗