Fabrication of phospholipid bilayer-coated microchannels for on-chip immunoassays.

Herein we describe a new class of microfluidic immunoassays based upon solid supported lipid bilayers. Two-dimensionally fluid bilayer material, which can accommodate multivalent binding between surface-bound ligands and aqueous receptors, was coated on the surface of poly(dimethylsiloxane) microchannels. The bilayers contained dinitrophenyl (DNP)-conjugated lipids for binding with bivalent anti-DNP antibodies. Twelve independent data points of surface coverage versus bulk protein concentration could be made simultaneously by forming a linear array of channels and flowing fluorescently labeled antibodies into them. This enabled an entire binding curve to be obtained in a single experiment. The measured apparent binding constant for the DNP/anti-DNP system was 1.8 microM. The methodology for performing heterogeneous assays developed here not only produces rapid results but also requires much less protein than traditional procedures and eliminates some standard sources of experimental error.

Immunoassay↗

Surface biopassivation of replicated poly(dimethylsiloxane) microfluidic channels and application to heterogeneous immunoreaction with on-chip fluorescence detection.

Poly(dimethylsiloxane) (PDMS) appeared recently as a material of choice for rapid and accurate replication of polymer-based microfluidic networks. However, due to its hydrophobicity, the surface strongly interacts with apolar analytes or species containing apolar domains, resulting in significant uncontrolled adsorption on channel walls. This contribution describes the application and characterization of a PDMS surface treatment that considerably decreases adsorption of low and high molecular mass substances to channel walls while maintaining a modest cathodic electroosmotic flow. Channels are modified with a three-layer biotin-neutravidin sandwich coating, made of biotinylated IgG, neutravidin, and biotinylated dextran. By replacing biotinylated dextran with any biotinylated reagent, the modified surface can be readily patterned with biochemical probes, such as antibodies. Combination of probe immobilization chemistry with low nonspecific binding enables affinity binding assays within channel networks. The example of an electrokinetic driven, heterogeneous immunoreaction for human IgG is described.

Dimethylpolysiloxanes↗

On-chip integration of sequential ion-sensing system based on intermittent reagent pumping and formation of two-layer flow.

A sequential ion-sensing system using a single microchip was successfully realized. The system developed here involves intermittent pumping of plural organic phases into a microchannel, followed by contact with a single aqueous phase to form a stable organic-aqueous two-layer flow inside the microchannel. Because the plural organic phases created by intermittent flow contain the same lipophilic pH indicator dye but different ion-selective neutral ionophores, different ions can be sequentially and selectively extracted into the different organic phases, where they can be determined by thermal lens microscopy (TLM). We used KD-A3 as the lipophilic pH indicator dye and valinomycin and DD16C5 as neutral ionophores to demonstrate sequential ion sensing of potassium and sodium ions by measuring the deprotonated dye caused by the ion extraction. The integrated microfluidic system proposed here allows multi-ion sensing, which is not easily demonstrated by conventional ion sensor technology using a solvent polymeric membrane. The minimum volume of single organic phase needed to obtain an equilibrium response without dilution by cross dispersion of two organic phases was ca. 500 nL in our system, indicating that the required amounts of expensive reagents in one measurement could be reduced to 1.7 ng and 2.8 ng for the dye and ionophore molecules, respectively.

Biosensing Techniques↗

Design and analysis of folded channels for chip-based separations.

Analytical methods are employed to investigate band broadening in a microchannel turn and adjoining straight channel segments for species transport by electrophoresis or electroosmotic flow. On the basis of closed-form solutions, we find that turn-induced broadening is negligible relative to total broadening when the radius of the turn exceeds some minimum. This minimum radius is about six-tenths of the product of the channel width and the Peclet number. We also find that the minimum radius is significantly reduced when a straight channel segment adjoins the turn in a folded configuration. Such straight segments noticeably reduce the minimum radius even for segment lengths comparable to the turn radius. The application of these results to folded and spiral channels is discussed, and sample calculations for practical conditions are presented. New pleated and coiled geometries for the compact layout of separation channels are also presented.

Journal Article↗

MALDI chip shot.

Explore the source record for details and available documents.

Comment↗

Genotyping on a complementary metal oxide semiconductor silicon polymerase chain reaction chip with integrated DNA microarray.

A novel method for the fast identification of genetic material utilizing a micro-DNA amplification and analysis device (micro-DAAD) consisting of multiple PCR microreactors with integrated DNA microarrays was developed. The device was fabricated in Si-technology and used for the genotyping of Chinese medicinal plants on the basis of differences in the noncoding region of the 5S-rRNA gene. Successful amplification of the genetic material and the consecutive analysis of the fluorescent-labeled amplicons in the micro-DAAD by the integrated oligonucleotide probes were demonstrated. Parallel analysis was performed by loading the four PCR reactors of the micro-DAAD with different samples of 3-microL volume. Temperature sensors and heating elements of the micro-DAAD enable precise temperature control and fast cycling, allowing the rapid completion of a combined amplification and analysis (hybridization) experiment.

Genotype↗

Sampling BIAS at channel junctions in gated flow injection on chips.

The commonly used gated injection scheme was examined and found to suffer from multiple levels of electrokinetic sampling bias, including a new type based on transradial electrokinetic selection (TREKS). TREKS occurs as analytes of differing electrophoretic mobilities migrate around the corner at a channel junction in a microchip. The overall sample bias in gated injection was shown to be time-dependent and resulted in a larger sample bias against components of negative electrophoretic mobility. A new injection procedure for microchip devices based on interstream diffusion at zero potential is proposed. Diffusion of molecules into the separation channel is the main driving force for this type of injection. The new scheme is shown to be useful for injection of complex samples with multiply charged components, such as peptide mixtures. This procedure allows sampling of volumes from 12 to 45 pL, reproducible retention times (RSD < 1.5%), and reproducible peak areas (RSD < 2.3%).

Electrophoresis↗

Stopped-flow enzyme assays on a chip using a microfabricated mixer.

This paper describes a microfabricated enzyme assay system including a micromixer that can be used to perform stopped-flow reactions. Samples and reagents were transported into the system by electroosmotic flow (EOF). Streams of reagents were merged and passed through the 100-pL micromixer in < 1 s. The objective of the work was to perform kinetically based enzyme assays in the stopped-flow mode using a system of roughly 6 nL volume. Beta-galactosidase (beta-Gal) was chosen as a model enzyme for these studies and was used to convert the substrate fluorescein mono-beta-D-galactopyranoside (FMG) into fluorescein. Results obtained with microfabricated systems using the micromixer compared well to those obtained with an external T mixing device. In contrast, assays performed in a microfabricated device by merging two streams and allowing mixing to occur by lateral diffusion did not compare well. Using the microfabricated mixer, Km and kcat values of 75 +/- 13 microM and 44 +/- 3 s(-1) were determined. These values compare well to those obtained with the conventional stopped-flow apparatus for which Km was determined to be 60 +/- 6 microM and kcat was 47 +/- 4 s(-1). Enzyme inhibition assays with phenylethyl-beta-D-thiogalactoside (PETG) were also comparable. It was concluded that kinetically based, stopped-flow enzyme assays can be performed in 60 s or less with a miniaturized system of roughly 6 nL liquid volume when mixing is assisted with the described device.

Clinical Enzyme Tests↗

On-chip coupling of isoelectric focusing and free solution electrophoresis for multidimensional separations.

We have developed an acrylic microfluidic device that sequentially couples liquid-phase isoelectric focusing (IEF) and free solution capillary electrophoresis (CE). Rapid separation (<1 min) and preconcentration (73x) of species were achieved in the initial IEF dimension. Using full-field fluorescence imaging, we observed nondispersive mobilization velocities on the order of 20 microm/s during characterization of the IEF step. This transport behavior allowed controlled electrokinetic mobilization of focused sample bands to a channel junction, where voltage switching was used to repeatedly inject effluent from the IEF dimension into an ampholyte-based CE separation. This second dimension was capable of analyzing all fluid volumes of interest from the IEF dimension, as IEF was 'parked' during each CE analysis and refocused prior to additional CE analyses. Investigation of each dimension of the integrated system showed time-dependent species displacement and band-broadening behavior consistent with IEF and CE, respectively. The peak capacity of the 2D system was approximately 1300. A comprehensive 2D analysis of a fluid volume spanning 15% of the total IEF channel length was completed in less than 5 min.

Algorithms↗

Flow control valves for analytical microfluidic chips without mechanical parts based on thermally responsive monolithic polymers.

Monolithic plugs of poly(N-isopropylacrylamide) cross-linked with 5% methylenebisacrylamide have been prepared by photoinitiated polymerization within the channel of a microfluidic device. The volume change associated with the polymer phase transition at its lower critical solution temperature of 32 degrees C allows both the rapid swelling and the deswelling of the monoliths enabling the polymer to close or open the channel as it functions as a nonmechanical valve. Thermoelectric elements capable of changing the temperature of the system between 17 and 57 degrees C were used to actuate the valve. Flow through the device was monitored by fluorescence measurements via the laser-triggered photobleaching of a dye contained in the liquid phase. Photobleaching occurs quickly once the flow is stopped, and the time required to open and close the valve was 3.5 and 5.0 s, respectively. No changes in function were observed even after 120 open-close cycles. Although the 2-mm-long valve was prepared from a polymerization mixture consisting of only a 5% aqueous solution of monomers, it resists pressures of up to 1.38 MPa (200 psi) without observable structural damage.

Acrylic Resins↗

Chip with twin anchors for reduced ion suppression and improved mass accuracy in MALDI-TOF mass spectrometry.

A new sample target for matrix-assisted laser desorption/ionization mass spectrometry is described. The target consists of pairs of elevated hydrophilic anchor surfaces, positioned in proximity onto a microchip. The anchors are used to obtain separate preparations of sample and external standard, while both anchor surfaces are irradiated simultaneously by the laser pulse. Using a standard, based on six peptides, a 2-fold improvement in mass accuracy is observed. Also, ion suppression is significantly reduced. With a one peptide calibration standard, 22 tryptic fragments from a BSA digest are detected using the twin-anchor concept, whereas only 14 fragments are detected when the sample and standard are laser-ablated as a mixture from a conventional anchor target. A volume of approximately 30 pL of sample solution of angiotensin I is transferred to the anchor surface, under a thin layer of a perfluorocarbon, to prevent a concentration bias due to evaporation. With this arrangement, a detection limit of 1.5 amol was achieved with a signal-to-noise ratio of 22:1.

Adrenocorticotropic Hormone↗