Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ARTIFICIAL LIMBS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95Linked to original sources

Experience in prosthetic supply of patients with lower limb amputations in Croatia.

This study analyses some demographic characteristics of the amputees in Croatia, reason and level of amputation, care the amputees receive, the first prosthetic supply and functional level after rehabilitation. Anonymised data on all amputees in the Clinical Institute for Rehabilitation and Orthopaedic Aids in Zagreb (a national centre) were collected during the year 2000. Follow-up was undertaken for one year. As a result, the authors analysed 221 patients, classified into 3 groups according to the level of amputations: trans-tibial, except foot (TT), trans-femoral (TF) and bilateral amputations (bilateral). Among the population there were: 76% men and 24% women with average age of about 62 years (the average age of women was 8 years more than men). The most common diseases that resulted in amputation were: diabetes mellitus (DM) 48.9%; obstructive vascular diseases (OD): occlusive peripheral arterial disease, Buerger's disease and atherosclerosis 27.1%; trauma 11.3%; both OD and DM 7.2%; osteomyelitis (OM) 3.2% and tumours (TM) 2.3%. Average period from the amputation to admission for prosthetic supply was over 190 days but the average period from admission to discharge from the Institute was about 40 days. Prosthetic supply was accompanied by certain complications: flexion contractures of neighbouring joints, knee 37.9% and hip 35.2%; local complications of soft tissues: necrosis, wound dehiscence, soft tissue surplus, ischaemic tissue damage (the most frequent in TT amputation 35.9%) and phantom pain (55.7% of patients). Hours of daily use of the prosthesis at discharge was about 5 hours. Greater independence in fitting and removing the prosthesis was observed in patients with TT amputation (86.4%). In conclusion, it can be said that the time between the amputation and the beginning of the prosthetic supply, mobility at the time of admission, frequency of general and local complications and number of days in prosthetic supply, are very important for the result of rehabilitation.

Adult↗

Energy expenditure of below-knee amputees during harness-supported treadmill ambulation.

Traditional rehabilitation of amputees is primarily aimed at strengthening remaining musculature necessary for prosthetic use and gait training. Available gait training time, however, is often limited by pain, residual limb skin tolerance, and the patient's cardiovascular endurance. Harness-supported treadmill ambulation is a rehabilitation technique being used by physical therapists to decrease an individual's body weight by a given percentage during exercise. This, theoretically, allows an amputee to ambulate on a prosthesis at a lower energy cost. The purpose of this study was to compare the energy expenditure of healthy below-knee amputee volunteers with healthy able-bodied volunteers during harness-supported treadmill ambulation in order to determine if energy conservation is achieved. Subjects were tested on a treadmill, walking at .67 m/sec (1.5 mph) and 1.34 m/sec (3.0 mph) during each of the following randomized harness-supported treadmill ambulation situations: full body weight, 20% body weight supported, and 40% body weight supported. During the last minute of each trial, rate of perceived exertion, heart rate, and standardized indirect calorimetry oxygen consumption (VO2, ml/kg/min) measures were collected. Caloric expenditure (kl/min) was calculated using metabolic conversion equations. Peak heart rate, peak VO2, and peak kl/min were measured after the conclusion of the last walking trial by taking each subject to volitional fatigue. Data were analyzed for each harness-supported treadmill ambulation situation and group using analysis of variance (ANOVA). The researchers identified significantly lower ratings of perceived exertion, heart rates, and VO2s for able-bodied subjects vs. below-knee amputees for all trials. Both groups demonstrated significantly lower heart rates, VO2s, and kl/min at 1.34 m/sec with 40% body weight supported.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Functional outcome of rehabilitated bilateral lower limb amputees.

The functional outcome of rehabilitated bilateral lower limb amputees was studied. The study included 31 amputees who were admitted during 1980-1990 to a rehabilitation centre in the north of the Netherlands. The clinical notes made during the patients' admission were studied to obtain information about their characteristics, while mobility and prosthetic use were studied at discharge. The patients who were alive and willing to participate in the study were interviewed by a physician at their residence in November 1992, using among other things, the Sickness Impact Profile (SIP) and the Life Satisfaction questionnaire. Some 25 of the 31 patients were amputated for vascular reasons, 1 patient primarily for traumatic reasons and secondarily for vascular reasons, 5 patients for traumatic reasons. Eight patients had a bilateral trans-femoral amputation, 18 patients a bilateral trans-tibial amputation, 2 patients a combination of trans-tibial and knee-disarticulation amputation, 3 patients a trans-femoral/trans-tibial amputation. Mean age at second amputation was 66.3 years. Of the 31 amputees 21 were men and 10 women, 25 amputees were prosthetically rehabilitated during admission, 3 of them died during admission and 5 did not achieve mobility at discharge. In their activities of daily life 22 of the 28 patients alive at discharge were almost independent. At the time of the follow-up evaluation 17 of the 31 patients had died. For several reasons only 8 patients could be included in the follow-up, 6 vascular amputees and 2 traumatic amputees.(ABSTRACT TRUNCATED AT 250 WORDS)

Activities of Daily Living↗

Laboratory and clinical tests of a prototype pressure sensor for clincial assessment of prosthetic socket fit.

Lower limb prosthetic socket fabrication is a highly refined process relying on the prosthetist's skill and experience. Despite their best efforts, patients often return with complications. Additionally, clinical application of technological advances for the quantification of biomechanical factors at the socket interface has not changed in practice. Measuring pressure levels at the stump/socket interface could provide valuable information in the process of prosthetic socket fabrication, fit and modification. This paper presents findings on the performance of a prototype capacitance pressure sensor designed for prosthetic socket use. Bench tests using compressed air were performed to measure accuracy, hysteresis and drift responses in both a flatbed chamber and a custom-modified pressure vessel. For the contoured testing, the sensors were placed on nine sites on a positive trans-tibial stump mould and enveloped with a silicone liner. Additionally, a preliminary clinical evaluation was performed with two trans-tibial amputee subjects at the nine sites during normal ambulation. Bench test results showed that the prototype capacitance sensor performed well in all categories, exhibiting a 2.42% (flatbed) and 9.96% (contoured) accuracy error, a 12.93% (flatbed) and 12.95% (contoured) hysteresis error, and a 4.40% (flatbed) and 6.20% (contoured) drift error. The clinical study showed that after three hours of continual use, no noticeable sensor drift occurred between pre and post-test calibration values. The results from this study were encouraging and the authors hope to conduct further laboratory and clinical trials to assess the influence of shear force and dynamic loading on sensor response.

Ambulatory Care Facilities↗

Measurement properties of the Frenchay Activities Index among individuals with a lower limb amputation.

OBJECTIVE: To assess the reliability and validity of the original and a modified version of the Frenchay Activities Index (FAI) among individuals with a lower limb amputation. DESIGN: Two week test-retest design. SETTING: South Western Ontario Amputee Program, London, Ontario, Canada. SUBJECTS: Consecutive sample of 84 individuals, primarily men (78.6%), mean age 56.5 years with a unilateral transtibial (71.4%) or transfemoral amputation related to traumatic (59.5%) or vascular causes. INTERVENTIONS: All subjects completed a questionnaire containing the FAI and other scales, the 2-minute walk and timed up and go tests during a regularly scheduled clinic visit. Fifty-five subjects completed a second FAI which was mailed to them two weeks later. Twenty-nine others completed the second FAI upon return for testing related to another project. MAIN MEASURES: FAI, Activity-specific Balance Confidence Scale, Prosthetic Evaluation Questionnaire-Mobility Scale, 2-minute walk, timed up and go and walking device aid use. RESULTS: Relative reliability for the FAI (intraclass correlation coefficient (ICC) = 0.79) and FAI-18 (ICC = 0.78) was acceptable, however bias between measurements was detected. Hypothesized relationships (p < 0.001) between both FAI versions and the Activity-specific Balance Confidence Scale, Prosthetic Evaluation Questionnaire-Mobility Scale, 2-minute walk and timed up and go test were observed. Significant group differences were observed for amputation cause, mobility device use, age and years as an amputee. Neither version distinguished between amputee level or gender groups. CONCLUSIONS: The original and modified FAI are valid and reliable tools for unilateral amputees. Reliability is adequate to detect group but not individual level differences. Additional FAI-18 items did not substantially improve the ability to detect between-amputation-group differences.

Activities of Daily Living↗

[Significance of static prosthesis alignment for standing and walking of patients with lower limb amputation].

The influence of three alignment parameters of a transtibial prosthesis (sagittal foot position, plantar flexion, mediolateral foot position) on the load and motion of the lower extremity joints was investigated in 13 unilateral transtibial amputees. The aim was to determine whether a correlation exists between static prosthetic alignment and gait pattern that would allow an optimal biomechanical prosthetic alignment. The gait pattern was measured using kinematic, kinetic, and electromyographic methods. Statics was defined using the alignment apparatus L.A.S.A.R. Posture. The electromyogram of the m. vastus lateralis and m. biceps femoris was recorded on both sides. The motion of joints is described by joint angles. External joint moments define the mechanical loads. Alignment has almost no influence on muscle activity and joint mechanics of the contralateral leg. In contrast, prosthetic alignment affects clearly and systematically the load and motion of the knee joint during the stance phase on the ipsilateral side. The sagittal foot position influences the maximal flexion angle in the stance phase. The plantar flexion of the foot affects the temporal structure of knee motion. The mediolateral foot position causes correspondingly different varus and valgus moments acting on the knee. Swing phase motion does not depend on prosthetic alignment. The iEMG of the m. vastus lateralis is reduced. Innervation characteristics of the m. biceps femoris on the prosthetically fitted leg has completely changed. The ischiocrural muscles take over the neuromuscular action of the m. gastrocnemius to compensate for the external knee extension moment during the second part of the stance phase. Prosthetic statics determines if the knee joint is physiologically stressed in a standing posture and during walking. Statics will be correct if the anatomical knee axis of the standing amputee is located about 15 mm posterior to the load line in the sagittal plane. In the frontal plane, the load line touches the lateral patella border and strikes the middle of the foot about 5 cm anterior to the adapter. During walking, attention should be paid to performance of knee flexion in the stance phase.

Adult↗

The effect of foot and ankle prosthetic components on braking and propulsive impulses during transtibial amputee gait.

OBJECTIVE: To assess the influence of energy storage and return (ESAR) prosthetic feet and multi-axis ankles on ground reaction forces and loading asymmetry between lower limbs in transtibial amputees. DESIGN: Subjects wore 2 different prosthetic feet with and without a multi-axis ankle and were analyzed using a blind repeated-measures multivariate analysis-of-variance design. SETTING: Gait analysis laboratory. PARTICIPANTS: Fifteen healthy unilateral transtibial amputees (>55 y) who had an amputation at least 1 year before testing because of vascular disorders. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: The anteroposterior ground reaction force impulse, peak ground reaction forces, and braking and propulsion impulse duration were analyzed as subjects walked at a self-selected speed while wearing each of the 4 foot-ankle prosthesis combinations. Statistical analyses were used to determine if there was a significant foot, ankle, or foot-ankle interaction effect on the outcome measures for each foot (P<.05). RESULTS: Amputees generated a significantly greater propulsive impulse with the residual leg when wearing a multi-axis ankle with the ESAR and non-ESAR foot, which improved the propulsive symmetry between the residual and intact legs. There was no prosthetic foot effect on these measures. There were no significant differences in the peak residual-leg braking or propulsive ground reaction forces or the impulse durations due to the prosthetic foot, ankle, or foot-ankle interactions, although an increase in the propulsive impulse duration approached significance (P=.062) with a multi-axis ankle. CONCLUSIONS: These results suggest that amputee gait may improve with the prescription of multi-axis ankles that allow for greater propulsive impulses by the residual leg, which improve the loading symmetry between legs.

Amputation, Surgical↗

Prosthetic management of children in The Netherlands with upper limb deficiencies.

The aim of the study was to assess which children with congenital and acquired upper limb deficiencies were fitted with prostheses, what types of prostheses were prescribed as first, second and third prostheses, at what age prostheses were first prescribed and how long the children wore their prostheses. The design was a retrospective chart review at De Hoogstraat Rehabilitation Centre, Utrecht (The Netherlands). Medical files of all patients with congenital or acquired upper limb deficiencies who visited the outpatient clinic between 1972 and 1996 were reviewed, collecting data on patient characteristics, prosthesis prescription and use of prostheses. The group included 224 children, of whom 206 (92%) had congenital deficiencies. Of all children with unilateral congenital deficiencies, 54% had been fitted with prostheses, against 3% of all children with bilateral congenital deficiencies and 67% of all children with acquired deficiencies. In the congenital group, it was children with transverse defects of one-third or two-thirds of the forearm who had most frequently had prostheses fitted (85% of the children). Most of the children with unilateral congenital deficiencies had received passive prostheses as their first prostheses (80 of the 90 prescribed prostheses); children with acquired defects usually had active prostheses (8 of the 12 prescribed prostheses). Body-powered prostheses were most commonly prescribed as the second type of prosthesis. In the group of 119 children who had been seen before the age of 4 years and had been followed for at least three years, 63 had been fitted with one or more prostheses at a mean age of 2.6 (SD 2.5) years. Of the 46 children with congenital defects, 30 had been fitted with prostheses, and at the age of 12, two-thirds of them still used their prostheses (63%, 19/30). "De Hoogstraat" rehabilitation centre uses a restrained prosthesis prescription policy, depending on the type of deficiency and the expected functional benefits. Data on prosthesis use are encouraging, although a follow-up study is required to determine the functional outcome for prosthesis users and non-users.

Adolescent↗

Quality of life in survivors with a Van Ness-Borggreve rotationplasty after bone tumour resection.

BACKGROUND AND OBJECTIVES: In large malignancies of the distal femur, limb salvage may not be feasible. Amputation is often the treatment of choice. A Van Ness-Borggreve rotationplasty is an alternative when the sciatic nerve is free of tumour. The appearance of the rotated lower leg is poor, which justifies a general concern about the psychosocial functioning of these patients. The aim of the study was to assess the medium- and long-term effects on quality of life (QOL) after rotationplasty. METHODS: A self-report questionnaire included the SF-36, the Social Support List, and selected items from the European Organisation for Research and Treatment of Cancer (EORTC) questionnaires as well as study-specific questions. The questionnaire was mailed to 34 patients at once. All patients were older than 16 years and at least 1 year postsurgery (mean 6.3 years). The response rate was 96%. RESULTS: Patients' physical functioning was poorer than that of healthy peers but better in comparison to chronically ill patients. Levels of psychosocial functioning, general QOL, and social support were highly comparable with those of healthy peers. One-third to one-half of the patients reported negative effects of the surgery on initiating social and/or intimate contacts, body image, and sexuality. With respect to physical functioning, two-thirds of patients engaged actively in sports. Patients reported wearing the prosthesis continuously and were, in general, satisfied with its fit. CONCLUSIONS: Given the relatively high levels of QOL and psychosocial functioning of these patients, these results indicate that rotationplasty is a good alternative in the treatment of patients with a large malignancy of the distal femur.

Activities of Daily Living↗

Prosthetic loading during kneeling of persons with transfemoral amputation.

Observations in the field of lower limb prosthetic rehabilitation have shown that several transfemoral prostheses show signs of wear on some components of the knee unit. This is thought to be a result of severe loading developed during activities associated with kneeling. Some prostheses may have failed due to repetitive action of such loading. In order to determine the nature and magnitude of the loads developed during kneeling by persons with transfemoral amputation, and to investigate the influence of various prosthetic parameters, an analysis of the results of 162 tests in prosthetic knee hyperflexion was undertaken. The services of four males with amputation were enlisted. The measurements involved simultaneous use of two Kistler force platforms, a six-channel strain gauge transducer mounted on the prosthetic shank, and a data acquisition system. The critical loads for this configuration were found to be the shear force on the knee hinge, the shear force imposed by the knee chassis on the shin, and the bending moment tending to hyperflex the knee. These loads ranged from 0.6 to 6.2 kN, 0.9 to 6.7 kN, and from 18.3 to 155.7 Nm, respectively. To achieve a comfortable kneeling position, some prostheses permit foot rotation about the pylon axis of 90 infinity to allow the shank to be approximately parallel to the ground. Tests were also conducted with the prostheses in this configuration and the most influential prosthetic parameter was found to be the external rotation of the foot (toe-out angle). During kneeling, it was found that the loading was dependent upon the position of the torso relative to the prosthesis, but loads were much higher than those developed during level walking.

Artificial Limbs↗

Segment velocities in normal and transtibial amputees: prosthetic design implications.

Dynamic elastic response foot and ankle prostheses (Seattle-Lite, Flex Foot, etc.) used by transtibial amputees feature substantial design improvements over conventional designs (SACH, Single Axis, etc.). Despite this progress, transtibial amputees continue to expend greater energy than normals. Increased residual limb EMG data and altered gait patterns suggest that impaired mobility may be the cause of overactive muscles in early stance. Prosthetic mobility was therefore quantified by measuring foot, shank and thigh velocities in nine transtibial amputees, wearing three different foot designs: Single Axis (SA), Seattle Lite (SL) and Flex Foot (FF). The magnitude, timing and rate of segment velocities for each prosthetic design, characterizing early stance mobility, were compared with corresponding measures in normal, nonamputee (NA) controls using Dunnett's test. Regardless of foot type, transtibial (TT) amputees walked slower than non amputee controls (63.3-65.8 m/min versus 78.5 m/min, p < 0.05) and their stride length was shorter (1.21-1.26 m versus 1.41 m, p < 0.01). In early stance, peak foot and shank velocities were lower (p < 0.01) for both the SL and FF while only shank velocity was lower (p < 0.01) with the SA compared to NA controls. Significant delays in the timing of early stance events such as peak shank velocity, peak ankle plantarflexion and peak knee flexion compromised shank and knee stability in TT amputees. Foot and shank mobility was uncontrolled with the SA design while ankle mobility was restricted by the FF and SL feet. In NA controls on the other hand, appropriate timing and rate of segment velocity changes preserved dynamic stability and forward progression in early stance. This was evidenced by rapid decreases in foot and shank velocity as the thigh velocity increased during weight acceptance. Future prosthetic designs should provide TT amputees with improved ankle mobility that attempt to capture the dynamic characteristics of a normal articulation between the foot and shank segments during the early stance weight acceptance period.

Amputation, Surgical↗

A biomechanical analysis of the long-jump technique of elite female amputee athletes.

PURPOSE: The purpose of this study was to investigate whether female lower-limb amputees conform to the established long-jump model and to compare the kinematics of the approach and take-off phases for elite female transfemoral and transtibial amputee long jumpers. METHODS: Eight female transfemoral and nine female transtibial amputee athletes were videotaped (sagittal plane movements at 50 Hz) from third-to-last step to take-off during the 2004 Paralympic Games long-jump finals. After digitizing and reconstruction of 2D coordinates, key variables were calculated at each stride and during contact with the take-off board. Additionally, approach speed during the run-up of each jump was recorded (100 Hz) using a laser Doppler device (LDM 300 C Sport, Jenoptik Laser, Jena, Germany). RESULTS: The transfemoral amputees had a consistently higher center of mass height on the last three steps before take-off than the transtibial amputees. However, at touch-down onto the take-off board, they lowered their center of mass excessively so that from touch-down to take-off, they were actually lower than the transtibial amputees. This resulted in a greater negative vertical velocity at touch-down and may have inversely affected their jump performance. CONCLUSION: Female transtibial athletes conformed to the long-jump model, although adaptations to this technique were displayed. Female transfemoral athletes, however, exhibited no relationship between take-off speed and distance jumped, which may be attributable to their excessive lowering of their center-of-mass height at touch-down onto the take-off board. It is recommended that coaches and athletes proceed with caution when trying to replicate techniques used by able-bodied athletes because adaptations to the constraints of a prosthesis should be considered.

Amputees↗

Children with congenital deficiencies or acquired amputations of the lower limbs: functional aspects.

The aim of the study was to evaluate the use of prostheses, some secondary complications and functional aspects among children who had a congenital leg deficiency or an acquired leg amputation. Rehabilitation physicians were asked to refer children, aged 1-18 years, with a leg deficiency or amputation. Mentally retarded children, children who had only had a toe amputated and children within one year after amputation were excluded. A total of 88 children were included; 64 with a congenital deficiency and 24 with an acquired amputation. In 25 of these 88, both legs were affected; 28 children also had an arm deficiency or amputation. A structured interview was held and the Child-HAQ assessed. Five (5) questions from the Child-HAQ, all relating to leg functions, were analysed. All but 7 children had had a prosthesis fitted, most (89%) using it for almost the entire day. In the children with congenital deficiencies, the first prosthesis had been fitted at an average age of approximately 18 months. Four (4) of the 7 children without prostheses used orthopaedic footwear. The 10 children with congenital deficiencies necessitating prostheses with articulated knees had the first knee of this type fitted at an average age of approximately 37 months. Forty-seven (47) of the 88 children had needed one or more (secondary) operations. In the children with congenital deficiencies, this was usually a conversion procedure, while the children with an acquired amputation had usually been operated on for osseous overgrowth. Twenty (20) of the 88 children experienced or had previously experienced phantom sensations, 5 children phantom pain. Skin problems were common. Most children (95%) were able to walk, most of them (93%) more than 100 m and 93% of the children aged 4 years or over were able to cycle. Most children (94%) aged 6 years or over were able to don and doff their prostheses independently. Some 90% of the children aged 4 years or over attended a normal primary or secondary school. Most (93%) of the children were able to take part in the physical education programme at school, although frequently (47%) with some degree of difficulty. The functional abilities of 88 Dutch children with congenital leg deficiencies or leg amputations were found to be generally satisfactory. Most of the children used prostheses in their daily activities. Secondary complications were, however, frequent.

Adolescent↗

Measuring long-term outcome in people with lower limb amputation: cross-validation of the Italian versions of the Prosthetic Profile of the Amputee and Prosthesis Evaluation Questionnaire.

AIM: Recently 2 questionnaires have been developed for people with lower limb amputation to determine, in follow-up studies, the level of function and extent of prosthetic use, to measure major life domains connected with prosthesis function, and to study the factors potentially related to prosthetic use the Prosthetic Profile of the Amputee (PPA) and the Prosthesis Evaluation Questionnaire (PEQ). The purpose of the present study was: a) to produce Italian versions of both PPA (PPA-it) and PEQ (PEQ-it), using a validated procedure of cross-cultural translation; b) to analyse and discuss the internal consistency and construct validity of the main sections of the 2 questionnaires, in an Italian population. METHODS: The PPA questionnaire consists of 44 questions arranged in 6 sections. The PEQ is composed of 82 questions subdivided into 9 scales related to 4 sectors. In order to produce the Italian versions of the PPA and PEQ the forward/backward translation method was used. The final versions of the questionnaires were mailed to 110 patients and 95 of them returned the questionarries. RESULTS: The Cronbach's alpha of Locomotor Capabilities Index (LCI/5), part of the PPA, was 0.97, and those of the 9 PEQ-it scales ranged from 0.64 (appearance) to 0.95 (mobility, MO). The LCI/5 and MO correlated highly with each other (rs=0.81) and with the variables related to prosthesis use. There was a significant correlation among the PEQ-it domains concerning MO, prosthesis function, psycho-social aspects and well-being. CONCLUSION: Unfortunately, the acceptability and feasibility of both questionnaires (rather low completion rate, visual analogue scale format of PEQ, demanding scoring procedures) were sub-optimal, and their structure (item selection, response format, scaling properties, etc.) would need some refinement and simplification in order to facilitate a broader clinical use. On the other hand, findings for the LCI/5 (PPA) and MO (PEQ) are encouraging (particularly regarding the first scale) and confirm their sound practical and psychometric features.

Adult↗

Prosthetic rehabilitation for older dysvascular people following a unilateral transfemoral amputation.

BACKGROUND: Dysvascularity accounts for 75% of all lower limb amputations in the UK. Around 37% of these are at transfemoral level (mid-thigh), with the majority of people being over the age of 60 and having existing co-morbidities. A significant number of these amputees will be prescribed a lower limb prosthesis for walking. However, many amputees do not achieve a high level of function following prosthetic rehabilitation. OBJECTIVES: We aimed to identify and summarise the evidence from randomised controlled trials evaluating rehabilitation interventions for prosthetic ambulation following unilateral transfemoral amputation in older dysvascular people, whether community dwelling or institutionalised. SEARCH STRATEGY: We searched the Cochrane Peripheral Vascular Diseases Group Specialised Register (July 2006), the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2006, Issue 3), MEDLINE (1966 to February 2006), EMBASE (1980 to February 2006), CINAHL (1982 to December 2005), AMED (1985 to December 2005), several more specialised databases and reference lists of articles. We also searched the UK National Research Register (Issue 2, 2005) for ongoing trials and contacted experts in the field. No language restrictions were applied. SELECTION CRITERIA: Randomised and quasi-randomised controlled trials testing prosthetic rehabilitation interventions following a unilateral transfemoral or transgenicular amputation in older (aged 60 years or above) dysvascular people. DATA COLLECTION AND ANALYSIS: Two authors independently scanned the search results for potentially eligible studies and then, on obtaining full reports of these, selected studies for inclusion and exclusion. Two authors independently assessed methodological quality and extracted data. No data pooling was possible. MAIN RESULTS: Of 38 full reports obtained for consideration, one trial was included and four were excluded. The sole included trial was a short-term crossover randomised trial which tested the effects of adding three seemingly identical prosthetic weights (150 g versus 770 g versus 1625 g) to the prostheses of 10 participants with unilateral dysvascular transfemoral amputation. Eight participants were over 60 years of age. The trial found that four participants preferred the lightest weight (150 g), five preferred the middle weight (770 g) and one preferred the addition of the heaviest weight (1625 g). AUTHORS' CONCLUSIONS: There is a lack of evidence from randomised controlled trials to inform the choice of prosthetic rehabilitation, including the optimum weight of prosthesis, after unilateral transfemoral amputation in older dysvascular people. A programme of research, including randomised controlled trials to examine key interventions, is urgently required in this area.

Aged↗

Amputation and prostheses in Khartoum.

One hundred and seventy patients with major lower limb amputation (MLLA) presenting to The National Prosthetic-Orthotic Centre (NPOC) in Khartoum over a 1-year period were studied. There were 141 males and 29 females giving a M:F ratio of 4.9: 1.0, with mean age of 37 years (range 5-72 years). Forty-one patients (24%) underwent amputation of diabetic septic foot, 30 patients (17.6%) underwent amputation as a result of trauma from road traffic accidents and Madura foot, and war injuries accounted for 29 amputations (17%). One hundred and eleven patients had below knee amputation (BKA), 52 had above knee amputation (AKA) and seven patients had Syme's amputation. Diabetic amputees had higher rate of revisional surgery compared with others because of sepsis and/or flap necrosis. Stump pain was reported by amputees with excessive scarring of the stump and those with undue prominence of bony ends. There are two types of prostheses provided by the NPOC for both BKA and AKA: the peg leg and the conventional prostheses. The Syme's amputees were fitted with either simple hoof or articulated prostheses with solid ankle cushion heel (SACH). The peg leg consists of a leather lined side bearing metal socket connected to a rocker base by side steels. It is used by the country natives as it suits different weather and job conditions, particularly farming, and it can be repaired locally. The urban population use the conventional prostheses which is lighter in weight, can be put on and taken off easily and is cosmetically acceptable. However, these prostheses are more expensive and require frequent repair or replacement. The functional outcome of patient's rehabilitation with the prostheses was significantly affected by the level and indication of amputation. Those with BKA and those amputated because of trauma or Madura foot experienced better functional outcome compared with the diabetics, independent of age. 50% of patients with the AKA and 19% of those with BKA reported poor functional outcome. Surgeons should be more involved with the long-term evaluation of functional outcome in such patients, to offer help if feasible and to modify their technique for future procedures.

Adolescent↗

The application of implant technology for cybernetic systems.

OBJECTIVE: To assess the usefulness, compatibility, and long-term operability of a microelectrode array into the median nerve of the left arm of a healthy volunteer, including perception of feedback stimulation and operation of an instrumented prosthetic hand. SETTING: The study was carried out from March 14 through June 18, 2002, in England and the United States. RESULTS: The blindfolded subject received feedback information, obtained from force and slip sensors on the prosthetic hand, and subsequently used the implanted device to control the hand by applying an appropriate force to grip an unseen object. Operability was also demonstrated remotely via the Internet, with the subject in New York, NY, and the prosthetic hand in Reading, England. Finally, the subject was able to control an electric wheelchair, via decoded signals from the implant device, to select the direction of travel by opening and closing his hand. The implantation did not result in infection or any perceivable loss of hand sensation or motion control. The implant was finally extracted because of mechanical fatigue of the percutaneous connection. Further testing after extraction has not indicated any measurable long-term defects in the subject. CONCLUSIONS: This implant may allow recipients to have abilities they would otherwise not possess. The response to stimulation improved considerably during the trial, suggesting that the subject learned to process the incoming information more effectively.

Adult↗

Long-term lower extremity prosthetic costs in children with traumatic lawnmower amputations.

OBJECTIVES: To evaluate prosthetic costs of pediatric lawnmower amputations; to see if reducing the incidence of pediatric lawnmower amputations could result in significant cost savings; and to consider if a cost analysis could be useful to implement more safety features (voluntarily or legislatively). DESIGN: Pediatric lawnmower amputees from 1980 to 2000 were reviewed to determine age at time of injury, level of amputation, number of prostheses, and lifetime per prosthesis. A standard prosthetic program beginning at amputation and ending at age 18 years was constructed. An aggregate cost was calculated according to the proportion of amputation levels. The cost burden for prosthetic care was estimated from the statistics of US pediatric lawnmower injuries. SETTING: Referral pediatric orthopedic center. PATIENTS: Fifty-three lower extremity amputees with 58 lower extremity amputations at a mean +/- SD age of 4.7 +/- 2.5 years were reviewed. RESULTS: The percentage of amputee children injured by riding lawnmowers was 80%; the percentage injured by riding lawnmowers engaged in reverse was 39%. Prosthetic costs from the time of injury to the age of 18 years range from 73,140 dollars to 116,040 dollars per single lower extremity amputation. With 600 to 650 new childhood amputations per year due to lawnmowers, the new annual burden for prosthetic costs thus ranges from 43.88 to 75.42 million dollars, or (600)(73,140 dollars) to (650)(116,040 dollars). CONCLUSIONS: Further encouragement of lawnmower manufacturers to install improved safety devices (such as those to disengage power while in reverse mode of operation), new research on improved safety measures, and continued promotion of educational campaigns regarding the dangers of children being around and/or operating riding lawnmowers and garden tractors should be pursued. This will result in significant cost savings as well as incalculable health savings.

Amputation, Traumatic↗