Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ARTHROPLASTY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95Linked to original sources

Reliability analysis of 16-MDCT in preoperative evaluation of total knee arthroplasty and comparison with intraoperative measurements.

OBJECTIVE: The aim of our study was to determine how consistent measurements of the distal femoral condyle on 16-MDCT are with intraoperative measurements and the reliability of 16-MDCT for the preoperative planning of total knee arthroplasty. MATERIALS AND METHODS: Between August 2003 and March 2004, 33 consecutive patients (two men and 31 women; age range, 53-89 years; mean age, 71 years) presenting with osteoarthritis underwent 16-MDCT (Mx 8000 IDT) of a total of 53 knees before total knee arthroplasty. The prospective analysis included measurements of transepicondylar distance, maximum anteroposterior dimension of medial and lateral femoral condyles, and trochlear width on a Rapidia workstation. To increase reliability, we repeated the measurements on a CT workstation after 2 months and compared them with the previous values. The values measured on the CT workstation were compared with the measurements obtained in the intraoperative field. Statistical analysis was performed using kappa statistics. A p value of less than 0.05 was considered statistically significant. RESULTS: The mean values of transepicondylar distance, maximum anteroposterior dimension of medial and lateral femoral condyles, and trochlear width were 75, 57, 58, and 38 mm at first measurement; 76, 58, 59, and 39 mm at second measurement on the CT workstation; and 79, 57, 60, and 42 mm at intraoperative measurement, respectively. At reliability analysis between the first measurements on the CT workstation and the intraoperative measurements, kappa values were 0.84 for the transepicondylar distance, 0.81 for the maximum anteroposterior dimension of the medial femoral condyle, 0.89 for the maximum anteroposterior dimension of the lateral femoral condyle, and 0.62 for the trochlear width. The kappa values for the second measurements were 0.86, 0.77, 0.84, and 0.61, respectively. Intraoperative measurements and measured values on the CT workstation showed excellent and almost perfect agreement, and intraobserver agreement was almost perfect. CONCLUSION: Femoral sizing on a CT workstation had excellent or almost perfect correlation with intraoperative measurements. Therefore, reliable preoperative planning for total knee arthroplasty may be done with 16-MDCT and an advanced workstation.

Aged↗

Sonography of polyethylene liners used in total knee arthroplasty.

OBJECTIVE: We investigated the ability of sonography to reveal the polyethylene liner used in total knee arthroplasty with the hopes of establishing a possible relationship between the sonographic measurement of the actual thickness of the polyethylene liner and the estimated thickness based on conventional radiography. MATERIALS AND METHODS: Twenty-four consecutive patients who were referred for Doppler screening for deep venous thrombosis after total knee arthroplasty were evaluated. The polyethylene liner was identified on sonography, and three measurements were obtained from four locations: anteromedial joint line (just medial to the midline incision), along the medial joint line, anterolateral joint line (just lateral to the midline incision), and along the lateral joint line. These sonographic measurements were compared with radiographic measurements of the radiolucent polyethylene liner and with the manufacturers' stated size of the polyethylene liner. Linear regression analyses were then performed. RESULTS: The polyethylene liner is seen on sonography as a strong linear echogenic interface with posterior acoustic shadowing. Linear regression analyses showed a high correlation (r = 0.8) between the sonographic measurements and the radiographic measurements. A relatively poor correlation (r = 0.2) was noted between the manufacturers' stated size of the liner and the sonographic measurements. CONCLUSION: We found that the polyethylene liner used in total knee arthroplasty can be clearly identified during sonographic evaluation of the knee. We also found a high correlation between the longitudinal measurement of the polyethylene liner with the thickness of the radiolucent polyethylene as measured on conventional radiographs. We propose that sonography could potentially be a useful noninvasive imaging modality to screen for subtle cases of polyethylene wear.

Aged↗

Clinical efficacy of the first metatarsophalangeal joint arthroplasty as a curative procedure for hallux interphalangeal joint wounds in patients with diabetes.

OBJECTIVE: To evaluate the safety and efficacy of first metatarsophalangeal joint arthroplasty compared with standard, nonsurgical management of wounds at the plantar hallux interphalangeal joint in patients with diabetes. RESEARCH DESIGN AND METHODS: We evaluated 41 patients with ulcers classified as University of Texas Grade 1A or 2A at the plantar aspect of the hallux interphalangeal joint using a case-control model [correction]. Case subjects were patients treated with resectional arthroplasty and control subjects received standard nonsurgical care. Both groups received standard off-loading and wound care. Outcomes included time to healing, reulceration, infection, and amputation. RESULTS: The surgery group healed significantly faster than patients in the standard therapy group (standard 67.1 +/- 17.1 versus surgery 24.2 +/- 9.9 days, P = 0.0001), and they had fewer recurrent ulcers (standard 35.0 versus surgery 4.8%, P = 0.02, odds ratio 7.6, 95% CI 1.1-261.7) Both groups had similar rates of infection (standard 38.1 versus surgery 40.0%, P = 0.9) and amputation (standard 10.0 versus surgery 4.8%, P = 0.5). CONCLUSIONS: Results suggest that resectional arthroplasty is a safe and effective procedure to treat wounds of the plantar hallux compared with nonsurgical therapy.

Age of Onset↗

Current concepts of total knee arthroplasty.

Total knee arthroplasty has become a reliable surgical procedure to treat painful degenerative arthritis. Pain relief and functional improvement is excellent and can allow patients to maintain an active lifestyle. Criteria for the type of prostheses selected should include diagnosis, age, functional level, severity of the disease, and patient expectations. Improved instrumentation, attention to surgical detail, including soft tissue balancing of the knee, and the use of polyethylene inserts greater than 8 mm have led to excellent long-term results and low failure rates. Recent improvements in revision total knee systems should significantly improve the long-term results of revision knee arthroplasty. The addition of modular implants has greatly increased the versatility of most systems and allows the surgeon to custom tailor the implant, contingent upon the amount of bony and ligamentous deficiency of the knee. The future goals of total knee arthroplasty include the development of knee systems that mimic normal joint kinematics with improved fixation and decreased polyethylene wear rates.

Arthroplasty, Replacement, Knee↗

A long term follow-up of Moore arthroplasty in femoral neck fractures.

Moore arthroplasty was performed for medial femoral neck fractures in 169 patients. The mortality rate was 21.3 per cent within 3 months. The general postoperative complication rate (39.6 per cent) was dominated by cardiopulmonary (17.2 per cent) and thromboembolic (16.0 per cent) events. Of local complications, wound infection was found in 4.7 per cent and osteitis in 3.0 per cent of cases. A total of 60 patients were followed up with a mean observation time of 4.9 years. Of these, 8.3 per cent sustained femoral fractures during this period. The results classified according to the criteria of the American Academy of Orthopedic Surgeons showed 52 per cent excellent or good, 43 per cent fair and 5 per cent poor results. The roentgenological finding of settling or osteolysis along the prosthesis was significantly correlated to reduced hip mobility. Ossification in the prosthetic fenestres gave significantly diminished settling, and was correlated to better hip mobility and less pain. In our opinion, Moore arthroplasty has proved to be an acceptable method for the treatment of femoral neck fractures in elderly patients, as 73 per cent had an acceptable range of motion, 40 per cent managed walking distances of more than 500 m and 70 per cent had minimal or no pain. Although 25 per cent became nursing home patients, this reduction of vitality could be related to the hip arthroplasty in only two cases.

Aged↗

Lateral dislocation of the patella following Marmor and Guepar arthroplasty of the knee.

The follow-up of 50 knees treated with the modular Marmor prosthesis and 50 with the Guepar hinge joint included tangential radiography of the femoro-patellar joint. After Marmor arthroplasty lateral patellar dislocation was found in seven knees, in six causing pain. After Guepar arthroplasty lateral patellar dislocation was found in 32 knees, but pain was present in only three. There was only a questionable correlation between pre-existing valgus deformity and postoperative lateral patellar dislocation, and an external rotation deformity of the lower leg was found in only five cases after Guepar arthroplasty. Thus, neither phenomenon could explain the high incidence of lateral patellar dislocation in the Guepar series. These dislocations must be assumed to be due to the unphysiological strain on the extensor apparatus inherent in this type of prosthesis.

Adolescent↗

St. Georg sledge for medial compartment knee replacement. 461 arthroplasties followed for 4 (1-17) years.

We evaluated the long-term outcome of 461 medial compartment knee arthroplasties operated at one orthopedic center from 1974 to 1993 through survivorship analysis. Prospective assessment was based on clinical examinations using a modified Bristol knee-scoring system and complete radiographical knee survey. 92% had good or excellent results on objective scoring, and range of motion averaged 112 degrees. 3 criteria were applied to indicate failure: 1) revision or recommended revision, 2) severe-to-moderate pain or revision, 3) lost to follow-up. 20 arthroplasties were revised or recommended to be revised at mean 5.5 years. The incidence of failure due to progression of arthrosis in the unreplaced compartment was low (< 2%). Loosening or wear occurred in 6 cases (1.5%), 2 of which developed fracture of implant. With revisions only as end-point to failure, the survival was 87% at 10 years (95% CI 81%-93%, effective number at risk = 133). In addition to revisions, 19 knees were considered to have failed, as moderate-to-severe pain was noted at follow-up and the survival was reduced to 74% at 10 years with pain or revision as endpoint (95% CI 65%-82%, effective number at risk = 105). We conclude that unicompartmental knee arthroplasty gives long-term pain relief in elderly patients with medial compartment arthrosis.

Aged↗

Validation of the Swedish Knee Arthroplasty Register: a postal survey regarding 30,376 knees operated on between 1975 and 1995.

The Swedish Knee Arthroplasty Register is dependent on the participating clinics regarding accuracy of information. As the register is prospective, and since revision is used as the endpoint in survival analyses, it is important that all revisions of registered primary arthroplasties are reported. To validate the register, we sent a questionnaire to all living patients with 30,796 knees registered as having been operated on from 1975-1995. Of living patients, 99% could be located and 93% answered. We found that one fifth of the revisions had not been reported and that relatively fewer revisions were lost to follow-up during the first decade of the register than in the following years. To investigate whether the Patient Administrative System (PAS), a database based on ICD coding and run by the Swedish health authorities, could be used to locate missing revisions found by the postal survey, we compared this database with the Swedish Knee Arthroplasty Register. 84% of the missing revisions revealed by the postal survey were found by using this method. Hence after the survey and the use of the PAS to find unreported revisions in deceased and non-responding patients, we estimate that 94% of all revisions are accounted for. Apart from a generally higher cumulative revision rate, conclusions reported from the Register in recent years regarding survivorship seem to be unaffected by the underreporting.

Arthroplasty, Replacement, Knee↗

Magnetic resonance imaging evaluation of adjacent segments after disc arthroplasty.

OBJECT: Disc arthroplasty in the lumbar spine is an alternative to fusion when treating discogenic pain. Its theoretical benefits include preservation of the motion segment and the potential prevention of adjacent-segment degeneration. Despite the need to evaluate the benefit of preserving the adjacent segments after disc replacement, no study has been conducted to assess the ability of magnetic resonance (MR) imaging to depict the adjacent segments in patients who have undergone disc replacement surgery. METHODS: Postoperative lumbar MR images were obtained in the first 10 patients in whom a metal-on-metal disc arthroplasty system was used to treat the L4-5 or L5-S1 levels. At the superior adjacent level, the superior endplate and disc space were demonstrated on 90% of the images on both T1-weighted fluid-attenuated inversion-recovery (FLAIR) and T2-weighted sequences despite the presence of artifacts. The inferior endplate at this level was documented on 70% of both T1-weighted FLAIR and T2-weighted sequences. At the level below the disc replacement in patients who underwent L4-5 surgery, the superior endplate was demonstrated on 66.7% of the T1-weighted FLAIR sequences but only 33.3% of the T2-weighted images. The disc space and inferior endplate were depicted on 66.7% of both T1-weighted FLAIR and T2-weighted sequences. Axial images revealed an artifact in every adjacent space except at the L5-S1 level. CONCLUSIONS: Based on the results of this pilot study, it appears that sagittal MR imaging can be undertaken to evaluate the adjacent motion segment for degenerative changes following total disc arthroplasty in most patients. This imaging modality will provide an additional measure to assess the long-term efficacy of this intervention compared with other treatment modalities and the natural history of lumbar disc degeneration.

Adult↗

Cervical disc arthroplasty: a controlled randomized prospective study with intermediate follow-up results. Invited submission from the joint section meeting on disorders of the spine and peripheral nerves, March 2005.

OBJECT: The authors of studies of anterior cervical fusion for disc-related disease have documented satisfying clinical results and infrequent complications. Recently, cervical disc arthroplasty has entered clinical trials as an alternative to fusion. Although the results of anecdotal reports and prospective studies support this procedure, these studies have not conferred the validity of a controlled randomized study. In the present study, the author presents data obtained in such a study. METHODS: After symptoms failed to respond to conservative therapy, 46 patients with one-level discogenic cervical radiculopathy and/or myelopathy were randomized to undergo arthroplasty or fusion as part of a US Food and Drug Administration medical device study. In all patients there was a minimum follow-up duration of 1 year. Equivalent results for the relief of arm pain and neck pain were noted in both treatment groups. Treatment parameters other than operative time were similar. No neurological or serious systemic complications occurred. CONCLUSIONS: Although extended follow-up data and larger patient populations are needed, the results of this study indicate that arthroplasty is a viable alternative to cervical fusion.

Arthroplasty↗

Treatment of symptomatic adjacent-segment degeneration after lumbar fusion with total disc arthroplasty by using the prodisc prosthesis: a prospective study with 2-year minimum follow up.

OBJECT: The authors conducted a prospective longitudinal study to assess the efficacy of ProDisc arthroplasty in patients in whom symptomatic adjacent-segment degeneration has developed after remote lumbar fusion. The follow-up period was a minimum of 2 years. METHODS: The 20 patients in this study ranged in age from 18 to 67 years. They presented with disabling adjacent-level discogenic low-back pain with or without L1-S1 radicular pain. Patients with radiographic evidence of circumferential spinal stenosis or facet joint degeneration had been excluded. Patients were assessed preoperatively and postoperatively at 3, 6, 12, and 24 months. Eighteen patients (90%) fulfilled all follow-up criteria. The median age of all patients was 50 years. Statistical improvements in visual analog scale, Oswestry Disability Index, and patient satisfaction scores were documented 3 months after arthroplasty. These improvements remained at the 24-month follow-up examinations. Patient satisfaction rates were 86% at 24 months. Radicular pain was also significantly decreased. No additional surgeries were necessary at affected or unaffected levels. CONCLUSIONS: Analysis of early results indicates that ProDisc lumbar total disc arthroplasty is an efficacious treatment for symptomatic adjacent-segment lumbar discogenic low-back pain following remote fusion. Significant improvements in patient satisfaction and disability scores were observed by 3 months postoperatively and were maintained at the 2-year follow-up examination. No device-related complications occurred. Patients should be screened carefully for evidence of facet joint impingement/degeneration, hardware-induced pain, and/or nonunion at prior fusion levels before undergoing disc replacement surgery.

Adolescent↗

Complications with cervical arthroplasty.

OBJECT: Spinal arthroplasty is becoming more widely performed in the treatment of degenerative cervical disc disease. Although this new technology may offer benefits over arthrodesis, it also requires that the surgeon acquire new operative techniques, and new potential complications are introduced. To determine the incidence and distribution of perioperative complications, the authors analyzed their early data obtained in a series of patients treated with the Bryan Cervical Disc prosthesis. METHODS: The authors prospectively recorded operative data, complications, and clinical and radiographic outcome data in all patients treated with Bryan prosthesis-based arthroplasty at two tertiary care centers since 2001. Patients underwent standard anterior cervical discectomy followed by one- to three-level arthroplasty. Ninety-six discs were implanted in 74 patients. The perioperative complication rate was 6.2% per treated level. In one patient a retropharyngeal hematoma developed, requiring evacuation. Neurological worsening occurred in three patients. Intraoperative migration of the prosthesis was observed in one two-level case, whereas delayed migration occurred in one patient with postoperative segmental kyphosis. In another patient with severe postoperative segmental kyphosis, revision was required with a customized lordotic prosthesis. Heterotopic ossification and spontaneous fusion occurred in two cases; motion was preserved in the remaining 94 prostheses. Partial dislocation of the prosthesis in extension occurred in one patient with preoperative segmental hypermobility, the first reported failure of a Bryan prosthesis. Twenty-five percent of patients reported neck and shoulder pain during the late follow-up period. There was a trend toward increased kyphosis of the C2-7 curvature postoperatively. CONCLUSIONS: The Bryan prosthesis was effective in maintaining spinal motion. Major perioperative and device-related complications were infrequent.

Adult↗

Wrist arthroplasty: a retrospective study.

A retrospective study was conducted to evaluate the long-term effectiveness of wrist arthroplasties in patients with various arthritic conditions. A total of 39 wrist arthroplasties were performed in 29 patients (average age, 52.5 years) by the orthopedic staff at Tulane University School of Medicine. Rheumatoid arthritis was the major presenting diagnosis in 84.6% of these operative cases and pain was the most common indication for surgery (79.5%). Postoperative relief of pain was reported in all of the cases reviewed, with an average follow up period of 51.2 months (range, 12 to 118 months). A group of 15 patients who were examined clinically had an average grip strength of 19.2 lb (range, 6 lb to 45 lb). Pinch measurements averaged 1.9 lb and arc of motion averaged 59.5 degrees (range, 20 degrees to 100 degrees) for these patients. Postoperative complications included dislocation (3 cases), fracture of the prosthesis (2 cases), and infection (2 cases). No complications were observed in 32 (82.1%) of the 39 cases reviewed. This retrospective study revealed that at an average follow up period of 51.2 months, pain relief was excellent and patient acceptance was good, with 94.9% of the wrists having been improved by the procedure. The majority (82.1%) of the cases were free of complication. It is concluded from this study that wrist arthroplasty is a viable alternative to wrist arthrodesis.

Adult↗

Clinical results of the modular porous-coated anatomic (PCA) total knee arthroplasty with cement: a 5-year prospective study.

Our study examines the clinical, radiographic, and patient satisfaction outcome of the cemented Modular Porous-Coated Anatomic (PCA) total knee arthroplasty with a minimum 5-year follow up. All data were gathered prospectively and consecutively. Patient satisfaction was assessed with a self-administered survey. Statistical analysis examined the effect of 17 patient factors, 19 surgical factors, and postoperative continuous passive motion use on range of motion (ROM) and HSS scores at 2 years. Seventy-eight Modular PCA arthroplasties performed by 9 orthopedic surgeons on 71 patients between January 1988 and November 1989 are reported in this study. Preoperative HSS scores averaged 51.2 and improved to an average of 89 at 1 and 2 years, and 86 at 5 years after surgery (90% good or excellent). ROM changed after surgery through improvement in preoperative knee flexion contracture, but not in increased knee flexion. One patient underwent reoperation for patellar instability, and one patient's arthroplasty was revised at 53 months for late instability. The total reoperation rate for any reason was 7.7%. Zonal analysis for progressive radiolucency at the bone-cement interface showed increasing frequency of narrow (< 1 mm) radiolucencies concentrated on the anterior and medial aspect of the tibial tray. Ninety-eight percent of patients responded to an outcome questionnaire, and 96% rated themselves improved. The Kaplan-Meier probability of an implant surviving without loosening at 5 years was 100%. The Modular PCA TKA has a low incidence of patellofemoral problems, is clinically successful, and results are stable at a minimum 5-year follow-up examination.

Activities of Daily Living↗

Fracture of the patella following total knee arthroplasty.

The charts of 21 patients (22 knees) with significant radiographic changes of the patella after total knee arthroplasty were reviewed. The average patient age was 73 years, and average follow-up after arthroplasty was 7.3 years. Lateral release, fat pad excision, quadriceps tendon release, and previous surgery were implicated in the etiology of fracture of the patella. Five cases had type 1 pattern (sclerosis, fragmentation, and no fracture), 5 cases had type 2 pattern (undisplaced fracture and fragmentation), and 12 cases had type 3 pattern (displaced fracture and fragmentation). Type 1 and 2 patterns required no surgical treatment and were rated good to excellent according to the Hospital for Special Surgery Disability Score Sheet. Patients with a type 3 pattern who did not undergo surgery were rated poor to fair, while patients with a type 3 pattern who underwent surgical treatment (patellectomy, removal of the patellar component, or excision arthroplasty for infection) were rated good. Patellectomy is the treatment of choice for patients with displaced fractures of the patella. A classification system for the pattern of patellar changes is proposed.

Aged↗

The role of concomitant biceps tenodesis in shoulder arthroplasty for primary osteoarthritis: results of a multicentric study.

This study evaluated the effects of concomitant biceps tenodesis in patients undergoing shoulder arthroplasty for primary osteoarthritis. Six hundred eighty-eight shoulders that had undergone replacement for primary glenohumeral arthritis were reviewed at a mean 43 months postoperatively. One hundred twenty-one patients had undergone a biceps tenodesis at arthroplasty, while the remaining patients did not. Tenodesis was significantly better than no tenodesis in most outcome parameters. No difference was found between the groups in complication rate. Biceps tenodesis is a useful adjunct to shoulder arthroplasty in the treatment of primary osteoarthritis.

Adult↗

Three decades of experience with unicompartmental knee arthroplasty: mistakes made and lessons learned.

Unicompartmental arthroplasty results and survivorship will continue to improve with time. The future will refine patient selection and bring better surgical techniques and prosthetic designs. Improved polyethylene will increase longevity of the arthroplasty, and mobile-bearing articulations also may improve longevity by decreasing wear and allowing a metal-backed component with relatively thin polyethylene inserts for a conservative arthroplasty.

Arthroplasty, Replacement, Knee↗

Role of the posterior cruciate ligament in total knee arthroplasty.

Since the introduction of condylar knee designs, total knee arthroplasty has become a remarkably successful and durable procedure. Improvements in instrumentation systems, fixation, and patellar resurfacing have been widely applied and have made total knee arthroplasty a reproducible procedure. The appropriate role for the posterior cruciate ligament in total knee arthroplasty, however, continues to be debated. Proponents of both cruciate substitution and cruciate retention can point to excellent clinical and radiographic results in the literature with knee designs of both types. Recent research findings in the areas of biomechanics, histology, and gait analysis, combined with refinements in intraoperative technique, have further sharpened the focus of the posterior cruciate ligament debate.

Arthroplasty, Replacement, Knee↗