Fiberoptic coupling device.
Explore the source record for details and available documents.
SEARCH · Search PubMed
Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
In this work we study the effects of the optical shrinkage in polymer and liquid crystal (LC) mixtures optimized for their use as active media in compact plastic laser devices. These mixtures are characterized by the presence of the rhodamine 6G as an active dye. Modifications in the reflection properties of the gratings as a function of the active dye concentration have been determined experimentally and a detailed theoretical simulation of the optical transmittance properties of these devices is provided. Moreover, the comparison between two different experimental approaches clarifies the contribution to the optical shrinkage due to the presence of the active dye. In principle this approach allows determining the linear mechanical shrinkage by separating the contribution to optical shrinkage due to photochemical transformations from that due to mechanical effects.
Silicon is the dominant semiconductor for electronics, but there is now a growing need to integrate such components with optoelectronics for telecommunications and computer interconnections. Silicon-based optical modulators have recently been successfully demonstrated; but because the light modulation mechanisms in silicon are relatively weak, long (for example, several millimetres) devices or sophisticated high-quality-factor resonators have been necessary. Thin quantum-well structures made from III-V semiconductors such as GaAs, InP and their alloys exhibit the much stronger quantum-confined Stark effect (QCSE) mechanism, which allows modulator structures with only micrometres of optical path length. Such III-V materials are unfortunately difficult to integrate with silicon electronic devices. Germanium is routinely integrated with silicon in electronics, but previous silicon-germanium structures have also not shown strong modulation effects. Here we report the discovery of the QCSE, at room temperature, in thin germanium quantum-well structures grown on silicon. The QCSE here has strengths comparable to that in III-V materials. Its clarity and strength are particularly surprising because germanium is an indirect gap semiconductor; such semiconductors often display much weaker optical effects than direct gap materials (such as the III-V materials typically used for optoelectronics). This discovery is very promising for small, high-speed, low-power optical output devices fully compatible with silicon electronics manufacture.
A typical radiology department can create many gigabytes of image data per day and as much as 1 terabyte of data per year. Archiving and accessing this much data are substantial problems. One solution is data compression, which decreases data storage requirements and increases the rate of data transfer; however, standards are not yet available. Other solutions involve improvements in archival media. Jukebox subsystems allow automated access to multiple units. Digital magnetic tape, the standard medium, can store large amounts of information and enables easy updates or replacements; more practical technologies have been introduced in recent years. Digital videotape allows storage of digital video data and features a high rate of data transfer. Optical disks, now the preferred permanent archival medium, have a large storage capacity and provide excellent long-term stability. Optical tape is also being investigated as a solution to the archiving dilemma. Which technology to choose depends on many factors, including needs of the institution and the cost, stability, transfer time, and storage capacity of the system.
A modular separation-based fiber-optic sensor (SBFOS) with an integrated electronically controlled injection device is described for potential use in remote environmental monitoring. An SBFOS is a chemical monitor that integrates the separation selectivity and versatility afforded by capillary electrophoresis with the remote and high sensitivity capabilities of fiber-optic-based laser-induced fluorescence sensing. The detection module of the SBFOS accommodates all essential sensing components for dual-optical fiber, on-capillary fluorescence detection. An injection module, similar to injection platforms on micro-analysis chips, is also integrated to the SBFOS. The injection module allows for electronically controlled injection of the sample onto the separation capillary. The design and operational characteristics of the modular SBFOS are discussed in this paper. A micellar electrokinetic capillary chromatography mode of separation is employed to evaluate the potential of the sensor for in situ monitoring of neutral toxins (aflatoxins). The analytical figures of merit for the modular SBFOS include analysis times of between 5 and 10 min, separation efficiencies of approximately 10(4) theoretical plates, detection limits for aflatoxins in the mid-to-low nanomolar range, and controllable operation that results in sensor performance that is largely immune to sample matrix effects.
Design and characterization of a general-purpose spectrometer for recording time-resolved emission spectra of typical fluorescent species is described. The system is based on a high repetition rate amplified Ti : sapphire system, an optical Kerr shutter for gating the emission, and a polychromator plus charge-coupled device (CCD) detection system. Using 1 mm of liquid benzene as the Kerr medium, and optics designed to provide high polarization quality, emission spectra of dilute solutions of solutes with nanosecond lifetimes can be recorded with good signal-to-noise ratios. The current spectrometer uses excitation wavelengths near 390 nm and provides spectra over the wavelength range 400-650 nm with 4 nm resolution and instrument response times of 450 fs (full width at half-maximum, FWHM). Selected applications are described to demonstrate the utility of this instrument.
This study compares the photosensitizer concentration measured noninvasively in vivo by diffuse reflectance spectroscopy with the results of postmortem tissue solubilization and fluorometric assay. The reflectance spectrometer consists of a fiber optic surface probe, spectrometer and charge-coupled device (CCD) array detector. The surface probe has eight detection fibers separated from the light source fiber by distances ranging from 0.85 to 10 mm. The imaging spectrometer disperses the light from each detector fiber onto the two-dimensional CCD array, while maintaining spatial separation of each individual spectrum. A single exposure of the CCD therefore captures the reflectance spectrum ar eight distances and over a range of 300 nm. From the spectra, the tissue's optical scattering and absorption coefficients are determined using a diffusion model of light propagation. Changes in the tissue absorption are used to estimate the photosensitizer concentration. Normal New Zealand White rabbits were injected with aluminum phthalocyanine tetrasulfonate (AlPcS4) and probe measurements made 24 h after injection on the dorsal skin, on muscle after surgically turning the skin back and on liver. For skin, the noninvasive estimate to proportional to the true concentration but low by a factor of 3. Based on Monte Carlo modeling of multilayered systems, this underestimate is attributed to the layered structure of the skin and nonuniform AlPcS4 distribution. A comparison of the noninvasive concentration estimates to the postmortem assay results finds good agreement for liver tissue even though application of the diffusion model is not strictly justified.
All-optical noninvasive control of a multisection semiconductor laser by means of time-delayed feedback from an external Fabry-Perot cavity is realized experimentally. A theoretical analysis, in both a generic model as well as a device-specific simulation, points out the role of the optical phase. Using phase-dependent feedback we demonstrate stabilization of the continuous-wave laser output and noninvasive suppression of intensity pulsations.
We have designed, constructed, and tested a thermoacoustic computed tomography (TCT) scanner for imaging optical absorption in small animals in three dimensions. The device utilizes pulsed laser irradiation (680-1064 nm) and a unique, 128-element transducer array. We quantified the isotropic spatial resolution of this scanner to be 0.35 mm. We describe a dual-wavelength subtraction technique for isolating optical dyes with TCT. Phantom experiments demonstrate that we can detect 5 fmol of a near-infrared dye (indocyanine green, ICG) in a 1-microL volume using dual-wavelength subtraction. Initial TCT imaging in phantoms and in two sacrificed mice suggests that three-dimensional, optical absorption patterns in small animals can be detected with an order of magnitude better spatial resolution and an order of magnitude better low-contrast detectability in small animals when compared to fluorescence imaging or diffusion optical tomography.
With the help of the research results presented here and on the basis of a graphic analysis we aim to prove the existence of a relationship between the difference in prismatic refractive power and the thickness, curvature radius, and type of material used for panoramic oculars in protective spectacles, goggles, and face shields. The difference in the prismatic refractive power is a fundamental optical characteristic of a protective ocular without corrective effect. According to Standard No. EN 165:1995 (European Committee for Standardization, 1995) the difference in the prismatic refractive power is a difference in the prismatic effect at 2 observation points of an eye-protector.
Quality Control (QC) is essential in cytologic laboratories. To reduce or avoid false negatives due to screening or interpretation errors, all cervical smears may be analyzed twice by two different cytopathologists (CP). During rescreening or Quality Control (QC), the second CP may be assisted by an automated device. Today there are different instruments: computerized microscope Ac Cell Series 2000 Pathfinder System), semiautomated or interactive systems (PAPNET, CytoRich or AutoCyte, ACCESS), automated systems (AutoPap 300). These devices, except computerized microscopes, utilize algorithmic image analysis that values single cells using morphological features but has difficulty in analyzing clusters of overlapping cells. For this reason it is better to use thin or monolayer preparations. This approach results in the loss of background and cells useful for the diagnosis and modifies sampling and processing methods. However, the techniques to obtain thin or monolayer preparations may process a higher number of cells than conventional method; moreover, the samples obtained may be valued also by the optic microscope, making cytologic analysis easier. The only device that combines the use of algorithmic image analysis with neural networks is the PAPNET system. Neural networks was inspired by neurobiology and may identify different cellular morphology and overlapping cells. In our laboratory, the PAPNET was proposed in 1995. In the present study, the last rescreening results of 1958 negative cervical smears are reported, analyzed during primary screening from July 1997 to February 1998. During the QC assisted by the PAPNET, 6 false negatives (0.31%), due to cytologic errors in the primary screening were detected. These results confirm the usefulness and the effectiveness of QC assisted by automated devices. However, only the CP evaluates abnormal cells detected by semiautomated systems or analyzes more atypical smears identified by the instruments. The work of CP is difficult: therefore a strict collaboration between clinician and CP to formulate the correct diagnosis is essential.
STUDY OBJECTIVE: To determine if the DxTek monitor, which is a device that measures blood pressure (BP) noninvasively and continuously by means of pulse velocity and wave shapes derived from the pulse oximeter optical plethysmograph and electrocardiogram is as accurate as an oscillometric cuff device when compared with intraarterial BP measurement. DESIGN: Prospective, comparative study. SETTING: University Medical Center. PATIENTS: 28 intensive care unit patients. INTERVENTIONS: Blood pressures were reported every minute by intraarterial catheters and DxTek and every 10 minutes by an oscillometric monitor for 2 to 5 hours. DxTek calibration was performed initially and when specified patient manipulations by caretakers were performed (on average, every 100 minutes). Comparisons with intraarterial pressure included: 1) DxTek calibrated with arterial catheter pressure, 2) DxTek calibrated with oscillometric pressure, and 3) oscillometric pressure. MEASUREMENTS AND MAIN RESULTS: When comparing oscillometric pressure to intraarterial pressure, the averages of the mean differences (bias) were -4.0 mmHg for systolic (SBP) and < 1.5 mmHg for diastolic (DBP) and mean (MAP) pressures. The averages of the standard deviation of the differences (precisions) were 9.6, 6.4, and 6.3 mmHg, respectively. With the DxTek device calibrated to intraarterial pressure, comparison of the DxTek pressure to intraarterial pressure resulted in a bias < OR = 0.5 mmHg for all three pressures and an average precision of 10.1 mmHg for SBP, 6.0 mmHg for DBP, and 6.7 mmHg for MAP. With the DxTek device calibrated to the oscillometric pressure, the DxTek pressure compared to the intraarterial pressure resulted in average biases of -5.1, -0.8, and -2.2 mmHg and average precisions of 11.1, 7.7, and 8.1 mmHg for SBP, DBP, and MAP, respectively. CONCLUSIONS: The DxTek monitor provides continuous, noninvasive BP measurements with an accuracy comparable to oscillometric devices.
Lanthanide ions possess fascinating optical properties and their discovery, first industrial uses and present high technological applications are largely governed by their interaction with light. Lighting devices (economical luminescent lamps, light emitting diodes), television and computer displays, optical fibres, optical amplifiers, lasers, as well as responsive luminescent stains for biomedical analysis, medical diagnosis, and cell imaging rely heavily on lanthanide ions. This critical review has been tailored for a broad audience of chemists, biochemists and materials scientists; the basics of lanthanide photophysics are highlighted together with the synthetic strategies used to insert these ions into mono- and polymetallic molecular edifices. Recent advances in NIR-emitting materials, including liquid crystals, and in the control of luminescent properties in polymetallic assemblies are also presented. (210 references.).
A central challenge for both the science and the technology of carbon nanotubes is the controlled assembly of devices. Here, we report a technique that allows us to place a nanotube with the desired properties in a predetermined location by direct mechanical transfer. We demonstrate single-tube and multiple-tube transfer and electrical characterization of an optically characterized nanotube. The ability to rationally design nanotube devices and circuits will enable more detailed study of the physics and chemistry of nanotubes and provide a stepping stone toward implementation of a wide spectrum of applications.
Two types of low-cost optical communication aids for non-vocal paralyzed patients are described: one based on reflection via mirrors and the other based on refraction via prisms. The recognition by the partner, when the handicapped person looks straight via the mirror/prism into his eyes, is crucial in the selection of the corresponding symbol in this communication process. The configurations in which the mirrors/prisms are arranged in aids of one- or two-dimensions, respectively. Preceding the choice of an advanced eye-controlled aid, eye defects can be detected using two-dimensional aids. Both types of optical communicators have been used in rehabilitation. The prism-aids appeared to be preferable to mirror-devices and to ETRAN-window in the communication process for speech replacement or in playing simple games.
Fiber optics for carbon dioxide laser surgery have been in developmental research for the past ten years. An up-to-date presentation of infrared fiber optics as they pertain to laser surgery is presented. Optical properties such as intrinsic and extrinsic electronic absorption, multiphonon absorption, and scatter mechanisms are discussed. Real-world considerations for materials selection and fabrication techniques for both crystalline and glassy fiber optics give the reader a perspective regarding the stage of development of these devices. Data are presented indicating transmission ranges and absorption coefficients for both bulk materials and fabricated fiber optics. The conclusions are drawn based on the needs of the clinician as they relate to the degree of existing technology.
The purpose of this work was to examine the dosimetric performances of the radiochromic Fricke-Agarose-Xylenol Orange gel by optical measurements in order to perform dose reconstructions, in view of a future development for 3-D maps. Optical images and dose-response curves of the gel were obtained by a CCD-based device, originally designed for reading radiochromic films, that was modified to meet the optical properties of the dosemeter. With a resolution of 0.18 x 0.18 mm the optimum range of doses in which per cent uncertainty is lower than 2% was 3-10 Gy. The minimum detectable dose, estimated as the absorbed dose corresponding to 3 SD above background, was 0.1 Gy. With a resolution of 1.98 x 1.98 mm the optimum range of doses in which per cent uncertainty is lower than 2% was 0.3-10 Gy. The minimum detectable dose, estimated as the absorbed dose corresponding to 3 SD above background, was 0.015 Gy. The comparison with alanine dosemeters in the dose range 7-10 Gy showed agreement within a few per cent and the same agreement was observed for the comparison with TLD in the range 1-3 Gy.
BACKGROUND: There are few published reports on the clinical application of Fresnel membrane prisms in the treatment of diplopia in adults. The authors describe the use of these prisms in patients with fourth and sixth cranial nerve palsies, restrictive motility caused by thyroid-related orbital disease, and convergence insufficiency. METHODS: Of 209 patients who had been treated with Fresnel prisms, 141 were selected. The database included patients from a private practice in Montreal, seen from 1988 to 1996, and patients seen by orthoptists in the ophthalmology department of a children's hospital in Montreal between 1992 and 1996. All the patients had diplopia associated with fourth (48 patients) or sixth (43 patients) cranial nerve palsy, thyroid-related orbitopathy (18 patients) or convergence insufficiency (32 patients). After qualitative and quantitative assessment of the ocular misalignment, a Fresnel prism was selected for power and axis and for appropriate location on the spectacle lens. Ocular dominance and side of paresis or restriction were also considered in the placement of the prism. The patient's response to treatment was documented. RESULTS: The Fresnel prisms were oriented horizontally in 72 patients (51%), vertically in 55 (39%) and obliquely in 14 (10%). They were placed on the spectacle lens before the nondominant eye in 127 cases (90%), either covering the entire lens, or on the upper or lower segment or both. The patients were followed for an average of 15 (range 2 to 96) months. Of the 141 patients 113 (80%) had a successful outcome, with relief of their diplopia. Twenty-seven patients (19%) eventually had the prismatic correction ground into the lens, 70 (50%) chose to wear the Fresnel prism on a permanent basis because incorporation into the lens was not possible or because of cost, and 17 (12%) used the Fresnel prism as a temporary device before or after surgery. Most patients who converted to incorporated prisms did so when the prismatic power became stable, usually after 6 to 8 months. Eight patients (6%) stopped using the prism because of associated side effects, such as blurred vision, persistent diplopia, torsion or optical aberrations. INTERPRETATION: The Fresnel prism is an excellent device in treating diplopia in adult patients. It is a reasonable permanent option when incorporating the prism into the spectacle lens is not possible. A fused blurred image caused by a Fresnel prism placed in front of the nondominant eye is preferable to double but clear images.