Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Fractures, Compression”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94Linked to original sources

Compression plating of pediatric femoral shaft fractures.

The authors conducted a retrospective review of 60 children under the age of 16 years with femoral shaft fractures treated with compression plate fixation. All patients were followed to hardware removal. The 100% union rate and low complication rate after compression plate fixation of pediatric femur fractures compared favorably to the literature of other treatment options. Compression plate fixation is a safe and effective treatment in children with both isolated femoral shaft fractures and those associated with multiple injuries.

Adolescent↗

Treatment of mandibular fractures by means of compression osteosynthesis.

This report is a retrospective study of 76 patients with mandibular fractures treated by compression osteosynthesis. Good results were achieved in 83% of the cases. The complications encountered were either soft tissue infections or minor malocclusions. It was concluded that the relatively low rate of complications can be further reduced by careful selection of patients and meticulous performance of the technique.

Adolescent↗

[Treatment of femoral shaft fractures and pseudoarthrosis with compressive and interlocking intramedullary nailing].

OBJECTIVES: We evaluated the results of compressive and interlocking intramedullary nailing in femoral shaft fractures. METHODS: Thirty-three femoral fractures of 30 patients (23 males, 7 females; mean age 36.9 years; range 14 to 80 years) were treated by compressive and interlocking intramedullary nailing. There were 26 closed and seven open (2 type II, 5 type IIIA) fractures. In three femurs, intramedullary nailing was performed due to pseudoarthrosis. According to the Winquist classification, there were 13, 8, 8, and 4 type I to IV fractures, respectively. Clinical, radiographic, and functional results were evaluated according to the Thoresen criteria. The mean follow-up was 29 months (range 6 to 29 months). RESULTS: The mean operation time was 105.7 minutes. Union was obtained in all the patients within a mean duration of 19.6 weeks. In six cases, dynamization was performed due to insufficient callus formation. The results were excellent in 17 patients (56.7%), good in eight patients (26.7%), fair in three patients (10%), and poor in two patients (6.7%). Complications included shortening (n=3; 2 to 4 cm), varus deformity (n=2; 8 and 11 degrees), external rotation (n=3), restriction in knee flexion (n=3), superficial infection (n=8), trochanteric bursitis (n=3), and irritation of the skin by distal screws (n=2). CONCLUSION: High rates of union with low complication rates makes interlocking intramedullary nailing an appropriate method in the treatment of femoral shaft fractures in adults. Compression with top screws contributes to the stability of fixation by eliminating any looseness through the fracture line.

Adolescent↗

Use of the talon hip compression screw in intertrochanteric fractures of the hip.

A retrospective analysis of a compression hip screw with four reversibly deployable talons was done. Fifty-four patients had sufficient radiographs to be included in this analysis. One-year mortality was 17% and increased to 41% by 2 years. No lag screws cut out, and postoperative slide was reduced compared with that in many published series. Three patients had revision of a failed alternate-type hip pin with the Talon hip compression screw. Previous studies showed the talons provide the definitive difference in allowing enhanced compression at the time of surgery, preventing cut-out by enhanced rotational stability, and allowing immediate postoperative weightbearing without excessive limb shortening. The failure mode of the Talon compression hip screw seems to be side-plate loosening rather than varus deformity and lag screw cut-out. The Talon compression hip screw especially is effective with weak, osteoporotic bone and in unstable, three-part and four-part fractures. A previous study showed that Talon deployment notably improved interfragment compression and torsional strength, and that engagement or penetration into or through the cortical bone at the base of the femoral head-neck junction in the inferior lag screw position was the critical technical step to maximize the talon lag screw purchase.

Adolescent↗

Risk of vertebral insufficiency fractures in relation to compressive strength predicted by quantitative computed tomography.

Vertebral insufficiency fractures may result from excessive loading of normal and routine loading of osteoporotic spines. Fracture occurs when the mechanical load exceeds the vertebral compressive strength, i.e., the maximum load a vertebra can tolerate. Vertebral compressive strength is determined by trabecular bone density and the size of endplate area. Both parameters can be measured non-invasively by quantitative computed tomography (QCT). In 75 patients compressive strength (i.e., trabecular bone density and endplate area) of the vertebra L3 was determined using QCT. In addition, conventional radiographs of the spines were analysed for the prevalence of insufficiency fractures in each case. By relating fracture prevalence to strength, three fracture risk groups were found: a high-risk group with strength values of L3 less than 3 kN (kilo Newton) and a fracture risk of 100%, an intermediate group with strength values from 3 to 5 kN and a steeply increasing risk with decreasing strength, and a low-risk group with strength values greater than 5 kN and a fracture risk near 0%. Biomechanical measurements and model calculations indicate that spinal loads of 3 to 4 kN at L3/4 will be common in everyday activities. These data and the results described above suggest that spines with strength values of L3 less than 3 kN are at an extremely high risk of insufficiency fractures in daily life. Advantages of fracture risk assessment by strength determination over risk estimation based on clinically used trabecular bone density measurements are discussed.

Adult↗

The effect of lossy discrete cosine transform compression on subtle bone fractures.

Extensive research efforts have been devoted to the feasibility of picture archiving and communication systems (PACS) in recent years. The advantages of PACS are numerous but mainly include reduced cost and improvement in the operational efficiency of a PACS-based radiology department. In digital radiography, images are viewed either in hard-copy or soft-copy format. Usually, these images are subsequently compressed and archived for future evaluation. There are various methods used in image compression. In this study, computed radiography images showing subtle pediatric bone fractures were compressed with the lossy method of image compression after they had been initially evaluated on workstation monitors. These studies were subsequently evaluated by observers, who were unaware of the interpretations of these images before compression, to determine if they could detect similar abnormalities. Our conclusion is that there is no difference in the interpretation of soft-copy computed radiographic images before or after lossy 10:1 compression in studies of subtle pediatric bone fractures. This is a US government work. There are no restrictions on its use.

Analysis of Variance↗

Pelvic fracture mechanism of injury in vehicular trauma patients.

To investigate the correlation between motor vehicle crash mechanisms and pelvic injury in front-seat occupants, we retrospectively reviewed the clinical records of, and had complete crash reconstructions performed for, 145 vehicular trauma patients with injury Severity Scores greater than 16 admitted to a level I trauma center. After excluding rear-seat and ejected occupants, 44 of the remaining 115 patients had pelvic injuries. We excluded acetabular fractures and classified the remaining 26 pelvic ring fractures by the system of Young and Burgess: 20 lateral compression (LC) fractures, five anteroposterior compression (APC) fractures, and one combined mechanical injury (CMI) fracture. Eighteen pelvic fractures were managed conservatively; eight required surgical intervention and four of those eight required emergent application of an external fixator for unresponsive hypotension. Trained investigation teams conducted the crash reconstructions, evaluating crash sites and vehicles with direct measurements of more than 500 variables. Calculations from these data, e.g., direction of impact and change in velocity at impact (delta V), were made with the CRASH III computer program and statistical analyses were performed using Chi-square and t tests. This information was then merged with the orthopedic evaluations.(ABSTRACT TRUNCATED AT 250 WORDS)

Accidents, Traffic↗

[Medial femoral neck fractures treated with hip compression screw. A product control study].

311 medial femoral neck fractures (213 of them displaced) treated with a hip compression screw were studied retrospectively. 90 patients were treated with a primary hemiprosthesis during the same period. Fixation was lost in the case of seven fractures within three months after the operation. Two patients developed pseudarthrosis and 53 late segmental collapse. 54 patients have been reoperated, and given an endoprosthesis. The radiographs of 176 patients (114 displaced fractures) who were accessible for follow-up until failure, or for at least three years, were analysed. The rates of late segmental collapse were particularly high for fractures with a postoperative anterior angulation exceeding 15 degrees. Displacement and time until operation were independently related to late segmental collapse.

Adult↗

Late compression neuropathies after Colles' fractures.

Conservative management of 166 Colles' fractures was associated with a 12% rate of late compression neuropathies (mean follow-up period, 28 months). Compression of the median nerve (8%) was twice as common as ulnar nerve compression (4%). Eighty-five percent of the patients with median nerve compression had malunion with radial collapse with or without other deformities (dorsal angulation/radial displacement). Patients with ulnar nerve compression had either malunion with radial collapse or volar subluxation of the ulnar head in those fractures that healed with dorsal angulation. Patients without nerve complications showed a significantly lower rate of malunions. These results demonstrate that anatomic derangements play a role in the development of late compression neuropathies following Colles' fractures.

Adolescent↗

A biomechanical evaluation of a cannulated compressive screw for use in fractures of the scaphoid.

The compressive force generated by a 3.5 mm ASIF cannulated cancellous screw with a 5 mm head was compared with that generated by a standard 3.5 mm ASIF screw (6 mm head), a 2.7 mm ASIF screw (5 mm head), and a Herbert screw. The screws were evaluated in the laboratory with the use of a custom-designed load washer (transducer) to the maximum compressive force generated by each screw until failure, either by thread stripping or by head migration into the specimen. Testing was done on paired cadaver scaphoids. To minimize the variability that occurs with human bone, and because of the cost and difficulty of obtaining human tissue specimens, a study was also done on polyurethane foam simulated bones. The 3.5 cannulated screw generated greater compressive forces than the Herbert screw but less compression than the 2.7 mm and 3.5 mm ASIF cortical screws. The 3.5 mm cannulated screw offers more rigid internal fixation for scaphoid fractures than the Herbert screw and gives the added advantage of placement over a guide wire.

Biomechanical Phenomena↗

Buckling of adaptive elastic bone-plate: theoretical and numerical investigation.

During day-to-day activities, many bones in the axial and appendicular skeleton are subjected to repetitive, cyclic loading that often results directly in an increased risk of bone fracture. In clinical orthopedics, trabecular fatigue fractures are observed as compressive stress fractures in the proximal femur, vertebrae, calcaneus and tibia, that are often preceded by buckling and bending of microstructural elements (Müller et al. in J Biomechanics 31:150 1998; Gibson in J Biomechanics 18:317-328 1985; Gibson and Ashby in Cellular solids 1997; Lotz et al. in Osteoporos Int 5:252-261 1995; Carter and Hayes in Science 194:1174-1176 1976). However, the relative importance of bone density and architecture in the etiology of these fractures are poorly understood and consequently not investigated from a biomechanical point of view. In the present contribution, an attempt is made to formulate a bone-plate buckling theory using Cowin's concepts of adaptive elasticity (Cowin and Hegedus in J Elast 6:313-325 1976; Hegedus and Cowin J Elast 6:337-352 1976). In particular, the buckling problem of a Kirchhoff-Love bone plate is investigated numerically by using the finite difference method and an iterative solving approach (Chen in Comput Methods Appl Mech Eng 167:91-99 1998; Hildebland in Introduction to numerical analysis 1974; Richtmyer and Morton in Difference methods for initial-value problems 1967).

Biomechanical Phenomena↗

Biomechanics of the Ilizarov fixator for fracture fixation.

Compression, distraction, and torsion stiffness of the Ilizarov external fixator was measured in two fracture models in autopsy specimens of tibia and fibula. A transverse model was tested in six frame constructions with the osteotomy site preloaded in four different positions. An oblique model was tested in four frame constructions also with four preloaded positions. Stiffness was more dependent on bone preload than wire number, wire type, or frame design. High stiffness was achieved by bone preloading, by compressing the rings together, by increasing the number of wires, and by using olive wires. The stiffness can be decreased (dynamization) by separating the rings and by removing wires. This data is helpful for frame design of the Ilizarov fixator.

Biomechanical Phenomena↗

Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures.

The use of volar locking compression plates for the treatment of fractures of the distal radius is becoming increasingly popular because of the stable biomechanical construct, less soft-tissue disturbance and early mobilisation of the wrist. A few studies have reported complications such as rupture of flexor tendons. We describe three cases of rupture of extensor tendons after the use of volar locking compression plates. We recommend extreme care when drilling and placing the distal radial screws to prevent damaging the extensor tendons.

Adult↗

[Stabilization of the fractured odontoid process with a compression screw].

The surgical technique for fractured dens stabilization with the use of compression screws was discussed. This method suggested by Böhler, in certain modification due to the equipment shortage, was applied in 8 patients operated shortly after injury has occurred. Relatively simple operative technique, good results, possibility to avoid head movements restrictions usually associated with posterior approach procedures makes this method valuable in certain cases especially in centers experienced in anterior approach spine surgery.

Adult↗

Internal fixation of an unstable open fracture of a distal phalanx with a Herbert screw.

A 20-year-old patient was seen with an unstable, infected, open fracture of the distal phalanx of the long finger of the right dominant hand. The patient was treated by removal of the nail, debridement of the fracture site, and stabilization of the fracture with a Herbert screw. The Herbert screw compressed the fracture site and allowed early active motion of the distal inter-phalangeal (DIP) joint. The wound healed without incident, and the fracture was radiographically united 6 weeks after the procedure. The Herbert screw is useful in the treatment of unstable fractures of the distal phalanx, since the screw maintains reduction, compresses the fracture site, and allows early active motion of the DIP joint.

Adult↗

Comparison of initial injury features in cervical spine trauma of C3-C7: predictive outcome with halo-vest management.

The purpose of this retrospective study was to examine specific patient variables and fracture morphologies to further elucidate the predictors of successful halo-vest treatment for cervical spine fractures (C3-C7). Eighty-seven cases of acute cervical spine injuries treated with halo-vest management were reviewed to assess initial injury features and radiographic outcomes by measuring (a) subluxation and direction, (b) angulation, (c) facet abnormalities, and (d) vertebral body fracture patterns on plain radiographs and computed tomography scans. The cases were divided into three groups: facet subluxations with fractures, facet subluxation without fractures, and fractures with no subluxation. Patients with facet subluxation and advance-staged compression-flexion fractures (stages 4 or 5) were a distinct group when treated conservatively with a halo. Despite anatomic reduction, facet subluxations associated with advance-staged compression-flexion fractures (stages 4-5), might be best treated surgically. Risk factors for late halo failure should include subluxations with advance-staged compression-flexion fractures when treated conservatively.

Adolescent↗