Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Electric Capacitance”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94Linked to original sources

Non-linearities in response properties of insect visual cells: an analysis in time and frequency domain.

Intracellularly recorded voltage responses of the visual cells of the blowfly (Calliphora erythrocephala) were analysed in the time and frequency domains. The photoreceptors were stimulated with pulse (impulse), sine, sine-sweep and pseudorandomly (white noise) modulated green light. The blowfly photoreceptor responses, as analysed from the linear transfer functions, seem to arise from a system similar to that of cascaded low-pass filters, with a corner frequency at about 63 Hz (SD +/- 12 Hz). The system is likely to have at least five poles, including one linear second order term, and a pure delay element. Arising from the non-linearities a second harmonic can be seen in the power spectra of responses elicited by sine modulated light. This non-linearity is at least partly explained by the self-shunting property of the membrane voltage response. Light adaptation increases the non-linearities in frequencies lower than 20 Hz, as seen in the decrease of the coherence function with the signal-to-noise ratio remaining constant. Light adaptation also accelerates the transduction process and it appears in the linear transfer function in a form typical to negative feedback. With low stimulus frequencies it causes a 'phase lead'-type non-linearity. In addition, the sine-sweep responses show quite different frequency characteristics in respect of depolarization and repolarization. Lateral inhibition between photoreceptor responses recorded from retinular cell axons in the lamina appears as a drop in gain and as an increasing phase-lag in frequencies from 30 Hz upwards in linear transfer functions. The source of this capacitive-like coupling can be considered to be in the high resistance barriers compartmentalizing the second optic ganglion into discrete anatomical units.

Adaptation, Ocular↗

Active hepatic capacitance responses to neural and humoral stimuli in dogs.

Active changes in hepatic capacitance were studied in pump-perfused dog livers during hepatic nerve stimulation or during intrahepatic arterial infusion of histamine (0.01-1 mg/l) or epinephrine (0.05 mg/l). Hepatic nerve stimulation at 5 pulses/s (pps) reduced hepatic blood volume by 76 +/- 39 (SD) ml/kg tissue and decreased the apparent hepatic compliance 36% from a control value of 25.6 +/- 9.3 ml.kg-1.mmHg-1, with constant flow perfusion. With a constant hepatic arterial pressure, 5 pps stimulation decreased hepatic arterial flow to 16% of control; the volume expelled was 91 +/- 33 ml/kg. Epinephrine caused hepatic artery constriction, the active expulsion of 71 ml/kg of blood, and a decrease of about 30% in hepatic compliance. Histamine dramatically reduced the hepatic vascular compliance, decreased the portal venous conductance, increased hepatic arterial conductance, and caused the apparent hepatic blood volume to double. Increased hepatic venous pressure, hepatic nerve stimulation, epinephrine, and, especially, histamine caused a significant filtration of fluid from the hepatic vasculature. We conclude that significant active capacitance changes and transsinusoidal fluid filtration can be induced in the canine liver by neural and hormonal stimuli.

Animals↗

Nanoscale dielectrophoretic spectroscopy of individual immobilized mammalian blood cells.

Dielectrophoretic force microscopy (DEPFM) and spectroscopy have been performed on individual intact surface-immobilized mammalian red blood cells. Dielectrophoretic force spectra were obtained in situ in approximately 125 ms and could be acquired over a region comparable in dimension to the effective diameter of a scanning probe microscopy tip. Good agreement was observed between the measured dielectrophoretic spectra and predictions using a single-shell cell model. In addition to allowing for highly localized dielectric characterization, DEPFM provided a simple means for noncontact imaging of mammalian blood cells under aqueous conditions. These studies demonstrate the feasibility of using DEPFM to monitor localized changes in membrane capacitance in real time with high spatial resolution on immobilized cells, complementing previous studies of mobile whole cells and cell suspensions.

Animals↗

Passive transmission of ischemic ST segment changes in low electrical resistance myocardial infarct scar in the pig.

OBJECTIVES: To analyze the passive electrical properties of a healed infarction and assess their role on transmission of contiguous ischemic ST segment potential changes. METHODS: We measured tissue resistivity (omega cm) at 1 kHz and the epicardial ST segment during 1 h of proximal reocclusion of the left anterior descending (LAD) coronary artery in 12 anesthetized pigs with one-month-old transmural infarction elicited by LAD ligature below the first branch. The impedance spectrum (1 to 1000 kHz) of normal and infarcted myocardium was measured in seven other pigs with similar infarctions. Electrical transmission of current pulses (30 microA) in infarcted tissue and in test solutions was also investigated. RESULTS: The infarct scar has a lower than normal resistivity (110 +/- 30 omega cm vs. 235 +/- 60 omega cm, p < 0.0001) and, unlike the normal myocardium, resistivity and phase angle of the scar did not change at increasing current frequencies, reflecting no capacitative response. LAD reocclusion induced a resistivity rise (510 +/- 135 omega cm, p < 0.01) and a ST segment elevation (0.6 +/- 0.7 to 9.5 +/- 5.1 mV, p = 0.002) in the ischemic peri-infarction zone, whereas the infarcted area showed ST segment elevation (0.5 +/- 0.5 to 3.8 +/- 2.6 mV, p = 0.03) with no resistivity changes. Potential decay of both ST segment and current pulses in the scar and in 0.9% NaCl solution was less than 1 mV/mm. Transmural deposition of connective tissue was seen in the center of the infarction. CONCLUSIONS: A one-month-old transmural infarction is a low resistance, noncapacitative medium that allows a good transmission of current pulses and of ST segment potential changes generated by contiguous peri-infarction ischemia.

Animals↗

Optimizing defibrillation through improved waveforms.

Defibrillation of the heart is achieved if an electrical current depolarizes the majority of the unsynchronized fibrillating myocardial cells. The applied current or the corresponding voltage described as a function of time is called the waveform. In pacing, to stimulate myocardial cells close to the electrode, a relatively low voltage is needed for a relatively brief duration. However, in defibrillation, approximately a 100-fold higher voltage is needed and achieved by the use of capacitors. The exponential voltage decay of a capacitor during its discharge determines the basic waveform for defibrillation. In an attempt to lower the energy needed for defibrillation, the steepness of the decay (different capacitances), the duration (fixed duration waveforms) or tilt (fixed tilt waveforms), or the initial polarity can be changed. Additionally, the polarity of the electrodes can be reversed during the discharge of the capacitor once (biphasic waveform) or twice (triphasic waveform). If two capacitors and defibrillation pathways are available, bidirectional defibrillation pulses can be delivered sequentially. In humans, the original standard waveform used with endocardial leads was a single monophasic pulse delivered by a 125-microF capacitor using the endocardial right ventricular electrode as cathode. It is now known that a reversal of the initial polarity and a reversal of polarity during capacitor discharge may significantly lower the energy needed for defibrillation, thereby preventing formerly frequent failures of defibrillation with endocardial lead systems. The use of sequential pulses showed no or only slight reductions of energy requirements and was abandoned due to the additional electrode needed. The use of a smaller capacitance (60-90 microF reduced maximum energy output but generally did not reduce energy requirements for defibrillation. However, with more efficient electrodes, smaller capacitances that will help to reduce the size of the defibrillator might be used. Thus, today defibrillation is optimized with respect to energy, capacitor size, and ease of implantation if an approximately 90-microF capacitor is used to deliver a biphasic pulse via a bipolar lead system using the right ventricular electrode as anode.

Animals↗

EMG needle electrodes: electrical impedance.

The electrical impedance of samples of stainless-steel monopolar needle electrodes and concentric electrodes from 3 manufacturers were measured in 154mM saline solution using sine-wave excitation at 4 frequencies from 10Hz to 10kHz. Current densities of less than 2.5x10(-5) amp/cm2 were used. Measurements on both needle and fine-wire electrodes were also made in live rats. Linear dimensions of the exposed tips were measured from which the areas of exposure were calculated. Surface areas of the monopolar needles varied between 0.06 and 0.15mm2. Presoaking of the electrodes for 20 minutes in saline solution containing a small concentration of a wetting agent produced a sixfold to twentyfold reduction in impedance. The average impedance magnitudes of the monopolar electrodes ranged from 1.4 megohms (Momega) at 10Hz to 6.6 kolohms (komega at 10kHz. The phase angle of the impedance due to the capacitive component of the needle-electrolyte impedance ranged between -45 and -71 degrees. The reduction in impedance resulting from presoaking and the concomitant reduction in electronic noise would be an advantage in observing lowamplitude potentials.

Animals↗

An optically coupled power stimulus isolation unit with high voltage and fast rise time output.

Recent technological developments have created new devices that could improve and simplify the construction of stimulus isolators. HEXFET transistors can switch large currents and hundreds of volts in nanoseconds. The newer opto-isolators can give a pulse rise time of a few nanoseconds, with output compatible with MOSFET devices, in which delays are reduced to nanoseconds. Integrated DC/DC converters are now available. Using these new resources we developed a new electrical stimulus isolator circuit with selectable constant-current and constant-voltage modes, which are precise and easy to construct. The circuit works like a regulated power supply in both modes with output switched to zero or to free mode through an opto-isolator device. The isolator analyses showed good practical performance. The output to ground resistance was 10(11) ohms and capacitance 35 picofarads. The rise time and fall time were identical (5 microseconds) and constant. The selectable voltage or current output mode made it very convenient to use. The current mode, with higher output resistance values in low current ranges, permits intracellular stimulation even with tip resistances close to 100 megaohms. The high compliance of 200 V guarantees the value of the current stimulus. The very low output resistance in the voltage mode made the device highly suitable for extracellular stimulation with low impedance electrodes. Most importantly, these characteristics were achieved with a circuit that was easy to build and modify and assembled with components available in Brazil.

Electric Stimulation↗

Nonlinear resonances of particles in a dusty plasma sheath.

Vertical oscillations of microparticles trapped in the sheath of a capacitive rf discharge have been excited showing a strongly nonlinear resonance. The nonlinear oscillations are analyzed in terms of an anharmonic fourth-order potential energy curve. It is demonstrated that the observed nonlinearities can be related to a position dependent charge of the microspheres, whereas the electric field is found to be as nearly linearly increasing. The experimental results on the position dependent charging and electric field structure are compared to a numerical model.

Journal Article↗

Cable properties of external intercostal muscle fibres from myotonic and nonmyotonic goats.

1. In preparations of about 200 fibres each from thirty-nine biopsies of external intercostal muscle taken from nine myotonic and six nonmyotonic goats, cable properties were determined at 38 degrees C for individual fibres with a pair of intracellular micro-electrodes.2. In each preparation the mean fibre dimensions, determined histologically and corrected for shrinkage, were used to calculate the mean membrane resistance, R(m), fibre capacitance, C(t), and myoplasmic resistivity, R(i). In the 124 nonmyotonic fibres the mean values were: R(m), 1897 Omega.cm(2), C(t), 4.1 muF/cm(2), and R(i), 112 Omega.cm. In 151 myotonic fibres R(m) was 5589 Omega.cm(2), C(t), 4.4 muF/cm(2), and R(i), 103 Omega.cm.3. Conductance of the fibre core times unit length increased with cross-sectional area, and fibre capacitance per unit length increased with perimeter. There was little correlation of membrane resistance per unit length of fibre with either fibre perimeter or resting potential.4. The principal abnormality of cable properties in the myotonic fibre is its threefold higher membrane resistance, which accounts for its decreased electrical current rheobase.

Animals↗

Total respiratory impedance measurement by forced oscillations: a noninvasive method to assess bronchial response in occupational medicine.

The forced oscillation technique is a noninvasive and effort-independent test to characterize the mechanical impedance of the respiratory system. By applying a complex signal, the frequency-dependent behavior of the respiratory system can be measured over an extended spectrum. For clinical practice, the input impedance is used most frequently; pressure and flow are measured at the same place. The impedance can be partitioned into a real part or resistance and an imaginary part or reactance. At low frequencies, reactance is determined by the capacitance of the system and at high frequencies by the inertial properties of the system. Equipment and impedance data in normal subjects and patients with chronic obstructive pulmonary disease are discussed. The frequency-dependent behavior of the respiratory system is described with the use of an electrical model characterized by partitioning of airway resistance and the presence of shunt compliance represented by the compliance of the intrathoracic airway walls. Influences of peripheral resistance, airway compliance, lung volumes, chest wall and pulmonary resistance, and resistance of the cheeks and upper airways are analyzed. Input impedance can be applied to the detection of bronchoconstriction and bronchodilation, but this technique is suitable for detecting early airway abnormalities caused by smoking or occupational hazards.

Airway Resistance↗

Electrical impedance tomography. An improved design of voltmeter for semi-parallel data acquisition.

The design and implementation of high performance differential voltmeters for semi-parallel data acquisition are described. The general requirements and specific conditions encountered in electrical impedance tomography (EIT) for accurate measurements are analysed. The major parameters are common-mode rejection and bandwidth. A specific implementation of the voltmeters, with separate DC supplies and independent signal references, is described. This arrangement, in which each voltmeter follows the input signal, automatically cancels any common-mode voltage present at the input. The signal is fed to the remainder of the instrumentation through a transformer. The use of a reduced number of components contributes to the minimisation of the inter-channel variations. Furthermore, the geometrical distribution of the voltmeters around the object minimises the length of electrode wires, also reducing the input capacitance. The number of modular voltmeters and DC/DC converters is 32. The common-mode rejection of these voltmeters is greater than 72 dB in the frequency range 3.6-560 kHz. In conclusion, the proposed solution ensures a minimisation of common-mode errors and enables the use of a 250 kHz frequency.

Electric Conductivity↗

Changes in intercellular electrical coupling of smooth muscle accompanying atrophy and hypertrophy.

Longitudinal tissue impedance was determined for cat circular intestinal muscle that was either hypertrophied due to volume overloading or atrophied due to defunctionalization. These conditions were produced by bypassing 50 cm of jejuno-ileum in six cats and, 2-6 mo later, removing segments from the proximal jejunum of the hypertrophied functional gut and from the atrophied proximal end of the bypassed loop. Impedances were compared with those of jejunal circular muscle from 15 normal cats. Specific tissue impedance was determined by a modification of the method of Tomita (J. Physiol. Lond. 201: 145-159, 1969), which employs Krebs and Krebs-sucrose solutions; a tissue shrinkage of 5%, empirically found to occur in Krebs-sucrose solution, was corrected for. Impedance values were determined at 20 frequencies between 30 Hz and 30 kHz. The value at 30 kHz was taken to represent the specific myoplasmic resistance (Rmyo) of each tissue, while the difference between the value of 30 Hz and 30 kHz was taken to represent the specific junctional resistance (Rj). Values (in omega X cm) for Rmyo were control 134 +/- 2, functional 128 +/- 5, bypassed 151 +/- 6 (mean of means +/- SE). Corresponding values for Rj were control 173 +/- 15, functional 96 +/- 27, bypassed 340 +/- 75. Calculated values (in microF/cm) for junctional capacitance were control 2.66, functional 6.10, bypassed 1.97. Acid uncoupling by saturating the bathing solutions with 100% CO2 revealed a pH-sensitive resistive component of Rj, assumed to be attributable to gap junctions.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Electrogenic bicarbonate secretion in the turtle bladder: apical membrane conductance characteristics.

We have recently shown that stimulation of electrogenic HCO3- secretion is accompanied by a simultaneous increase in short-circuit current (Isc, equivalent to HCO3- secretion rate under these conditions), apical membrane capacitance (Ca, proportional to membrane area), and apical membrane conductance (Ga, proportional to membrane ionic permeability). The current experiments were undertaken to explore the ionic basis for the increase in Ga and the possibility that the rate of electrogenic HCO3- secretion is regulated by changes in Ga. Membrane electrical parameters were measured using impedance-analysis techniques before and after stimulation of electrogenic HCO3- secretion with cAMP in three solutions which contained different chloride concentrations. In another series of experiments, the effects of an anion channel blocker, anthracene-9-carboxylic acid (9-AA), were measured after stimulation of electrogenic HCO3- secretion with cAMP. The major conclusions are: (i) a measurable apical Cl- conductance exists in control hemibladders; (ii) the transport-associated increase in Ga includes a Cl(-)-conductive component; (iii) Ga also appears to reflect a HCO3- conductance; (iv) the relative magnitudes of the apical membrane conductances to Cl- and HCO3- are similar; (v) 9-AA reduces Ga and Isc in cAMP-stimulated hemibladders; and (vi) alterations in Isc appear to be mediated by changes in Ga.

Animals↗

Capacitance flickers and pseudoflickers of small granules, measured in the cell-attached configuration.

We have studied exocytosis of single small granules from human neutrophils by capacitance recordings in the cell-attached configuration. We found that 2.2% of the exocytotic events were flickers. The flickers always ended with a downward step. This indicates closing of the fusion pore. During flickering, the fusion pore conductance remained below 1 nS, and no net membrane transfer was detectable. After fusion pore expansion beyond 1 nS the pore expanded irreversibly, leading to rapid full incorporation of the granule/vesicle into the plasma membrane. Following exocytosis of single granules, a capacitance decrease directly related to the preceding increase was observed in 7% of the exocytotic events. This decrease followed immediately after irreversible pore expansion, and is presumably triggered by full incorporation of the vesicle into the patch membrane. The capacitance decrease could be interpreted as endocytosis triggered by exocytosis. However, the gradual decrease could also reflect a decrease in the "free" patch area following incorporation of an exocytosed vesicle. We conclude that non-stepwise capacitance changes must be interpreted with caution, since a number of factors go into determining cell or patch admittance.

Biophysical Phenomena↗

Electrical Impedance Analysis of Tissue Properties Associated with Ethylene Induction by Electric Currents in Cucumber (Cucumis sativus L.) Fruit.

A study based on electrical impedance analysis of tissue properties was conducted in order to understand the relationship between impedance components and ethylene biosynthesis induced by direct current in cucumber (Cucumis sativus L.) fruit. Impedances were measured at a range of alternating current frequencies from 500 Hz to 1 MHz. We calculated capacitances representing the plasma membranes, C1, and organelle membranes, C2, and resistances representing extracellular space, R1, cytoplasm, R2, and organelle interior, R3. Direct current of 1 to 3 mA induced ethylene synthesis with a sharp peak at 1 h. The rate of production was greater with a stronger current. This abrupt induction of ethylene synthesis was accompanied by an equally abrupt activation of 1-aminocyclopropane-1-carboxylic acid (ACC) synthase within 1 h, but not that of ACC oxidase, which was activated only at the later stages of the treatment at a time when ethylene production and ACC synthase activity were declining. Using direct current of 0 to 3 mA, C2, R1, and R2 increased abruptly, and C1 increased gradually after 3 h. The rates of increases were greater with currents of larger magnitude, R3 was not affected during passage of the current. Diazocyclopentadiene, an inhibitor of ethylene action, eliminated the direct current induction of R1 but had no effect on the increases in C2 and R2. Diazocyclopentadiene counteracted the stimulative effects of exogenously applied ethylene with respect to respiration and activities of ACC oxidase and phenylalanine ammonia-lyase. These results indicate that an externally applied current may generate signal(s) by altering the functions of organelle membranes and/or cytoplasmic pH to induce ACC synthase.

Journal Article↗

The role of the autonomic nerves in the control of nasal circulation.

Patients suffering from allergic or vasomotor rhinitis usually show nasal mucosal hyperaemia, engorgement, hyperrhinorrhoea and obstruction of the nasal airway. The nasal mucosa is drained by two venous systems which are anatomically and functionally separate. The nasal mucosa receives tone discharges from the sympathetic nerves but not from the parasympathetic nerves. Sympathetic nerve stimulation causes constriction of the resistance vessels via the alpha-adrenergic mechanism and constriction of the capacitance vessels via the alpha-adrenergic mechanism and some non-adrenergic and non-cholinergic mechanism; the capacitance vessels are under more prominent sympathetic influence than the resistance vessels. Parasympathetic nerve stimulation causes non-cholinergic dilatation of both resistance and capacitance vessels; dilatation is more pronounced in the posterior venous system. Simultaneous optimal stimulation of the autonomic nerves resulted in vasoconstriction, especially of the capacitance vessels. Hence, nasal congestion may be related more to a withdrawal of sympathetic discharge than to an overactivity of the parasympathetic nerves.

Animals↗

Vascular compliance and mean circulatory filling pressure in trout: effects of ACE inhibition.

Mean circulatory filling pressure (MCFP), whole body vascular compliance (C), and unstressed blood volume (USV) are important indexes of cardiovascular function in mammals, but they have not been measured in fish. In the present experiments, dorsal aortic (PDA) and sinus venosus (PSV) pressures were measured in unanesthetized trout before and during electrical cardiac fibrillation, while blood volume (BV) was manipulated between 50 and 150% of normal. Measurements were repeated after angiotensin-converting enzyme (ACE) inhibition with lisinopril. Cardiac fibrillation (zero-flow condition) rapidly (approximately 5 s) dropped PDA and increased PSV (equals MCFP). MCFP in normovolemic trout (4.8 +/- 0.3 mmHg) varied directly with BV. C determined from in vivo capacitance curves was similar to that obtained gravimetrically, in vitro (3.4 and 3.5 ml.mmHg-1.kg body wt-1, respectively). USV was 13.3 ml/kg body wt (approximately 45% of BV). ACE inhibition reduced PDA in unfibrillated trout at all BV and reduced PDA in fibrillated fish at BV > or = 80%. ACE inhibition did not affect PSV, MCFP, C, or USV. The systemic arteriovenous pressure gradient at zero flow (delta PF0) was greatest at 100% BV (8.2 +/- 0.5 mmHg) and was reduced by ACE inhibition at 80-120% BV. These results show that key indexes of venous function are readily measured in fish and that the trout venous system is not an effector of angiotensin-mediated regulation of arterial blood pressure. Thus angiotensin acts solely on arterial resistance vessels. Furthermore, the drop in delta PF0 during ACE inhibition is due to a decrease in arteriolar resistance.

Angiotensin-Converting Enzyme Inhibitors↗

Conductometric study of shear-dependent processes in red cell suspensions. II. Transient cross-stream hematocrit distribution.

A novel experimental approach based on electrical properties of red blood cell (RBC) suspensions was applied to study the effects of the size and morphology of RBC aggregates on the transient cross-stream hematocrit distribution in suspensions flowing through a square cross-section flow channel. The information about the effective size of RBC aggregates and their morphology is extracted from the capacitance (C) and conductance (G) recorded during RBC aggregation, whereas a slower process of particle migration is manifested by delayed long-term changes in the conductance. Migration-induced changes in the conductance measured at low shear rates (< or =3.1 s(-1)) for suspensions of RBCs in a strongly aggregating medium reveal an increase to a maximum followed by a decrease to the stationary level. The ascending branch of G(t) curves reflects the aggregate migration in the direction of decreasing shear rate. A further RBC aggregation in the region of lower shear stresses leads to the formation of RBC networks and results in the transformation of the rheological behavior of suspensions from the thinning to the thickening. It is suggested that the descending branches of the G(t) curves recorded at low shear rates reflect an adjustment of the Hct distribution to a new state caused by a partial dispersion of RBC networks. For suspensions of non-aggregating RBCs it is found that depending on whether the shear rate is higher or lower compared with the prior value, individual RBCs migrate either toward the centerline of the flow or in the opposite direction.

Conductometry↗