Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Device Approval”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94Linked to original sources

Artecoll: a long-lasting injectable wrinkle filler material: Report of a controlled, randomized, multicenter clinical trial of 251 subjects.

Artecoll, an injectable wrinkle filler composed of polymethylmethacrylate microspheres and bovine collagen, is widely available outside the United States. For domestic availability, a multicenter Investigational Device Exemption study was required by the U.S. Food and Drug Administration. This study consisted of 251 subjects at eight centers who received injections of Artecoll or the currently approved collagen dermal filler (control) in 1334 wrinkles of the glabella, nasolabial fold, radial upper lip lines, and corner-of-the-mouth lines. The treatments were randomized, and follow-up safety, efficacy, investigator success rating, and subject satisfaction rating data were collected at 1, 3, and 6 months. The safety data, measured as adverse events and immunoglobulin G serum levels, were low and similar for both groups. The efficacy data, measured by masked observers using a photographic facial fold assessment scale, demonstrated a combined significant improvement with Artecoll compared with collagen at 6 months (p < 0.001). At 6 months, the investigator success ratings and the subject satisfaction ratings for each of the four injections sites were superior for Artecoll (p < 0.001). In the Artecoll group, 12-month follow-up was obtained for 111 subjects (86.7 percent) and showed persistence of significant augmentation. Artecoll had fewer adverse events reported throughout the 12-month safety study period than the control group did in 6 months, although the difference was not statistically significant.

Adult↗

Intravascular brachytherapy using 90Sr for saphenous vein grafts having diameters ranging from 2.0-5.0 mm.

PURPOSE: Symptomatic coronary artery disease is routinely treated with angioplasty and stenting. Unfortunately, treatment failure in the form of in-stent restenosis (ISR) occurs relatively frequently. Intravascular brachytherapy (IVBT) is a safe and effective method proven to markedly reduce the rate of ISR in native coronary arteries. The commercially available devices for IVBT are not FDA-approved for treatment of saphenous vein grafts (SVG). This article presents calculated dosimetry for treatment of a wide range of SVG, in addition to further evaluating the dose homogeneity for native coronary arteries. METHODS AND MATERIALS: AAPM Task Group 43 and 60 formalisms permitted dose calculations for a wide range of vessel internal diameters (phi) in both native coronary arteries and SVG. Doses were analytically calculated for the Novoste Beta-Cath 5.0 French (F) treatment devices (30, 40, and 60 mm sourcetrains) when employed for the treatment of native vessels with 2.7 <or= phi <or= 4.0 mm and for SVG with 2.0 <or= phi <or= 5.0 mm. This latter range of phi was segmented into 7 bins to facilitate rapid clinical implementation with minimal errors. Calculations of dose and dose rate for the 3.5 F devices were also performed. Dose inhomogeneity in the form of dose maxima and minima were calculated for the 3.5 and 5.0 F catheters, with the 30, 40, and 60 mm sourcetrains, and for 2.0 <or= phi <or= 5.0 mm. RESULTS: The calculated doses rates for the 30 mm device were in agreement (typically +/- 0.3%) with measured dose rates. Reference dose calculations performed for SVG with 2.0 <or= phi <or= 5.0 mm were in alignment with those used for the more narrow range of native coronary arteries currently approved for IVBT. Errors associated with using a phi binning technique for simplifying clinical implementation did not exceed 15%, and were typically under 9%. The degree of dose inhomogeneity at a depth of 0.5 mm increased as phi increased, catheter size decreased, and sourcetrain length decreased, and was -42% and +101% relative to the prescribed dose for the 40 mm 5.0 F system with phi = 4.0 mm. CONCLUSIONS: Use of 7 phi bins facilitates rapid clinical implementation of IVBT in the typical cardiac catheterization laboratory. While calculation of reference dose for treatment of large vessels is possible with established formalisms, the degree of dose inhomogeneity in light of current clinical results suggests further research is needed.

Brachytherapy↗

Summary and Comparison of Atrial Septal Defect Closure Devices.

A large number of atrial septal defect (ASD) closure devices have been investigated in an attempt to develop a nonsurgical, transvenous method of occlusion of ASD. Some of the devices have been discontinued and several are in clinical trials at this time, but none are approved for general clinical use. There are no prospective, randomized clinical trials to compare the available devices. Based on separate clinical trials, the feasibility, safety, and effectiveness of all devices appear similar. Considerations pertaining to the size of the device delivery sheath, ease of implantation, cost and availability are different with each of the devices; some devices have advantages in some aspects, and others with another. Approval by the regulatory authorities and larger clinical use with longer follow-up results may eventually determine the most appropriate device for a given clinical use.

Journal Article↗

Delegations of authority and organization; Center for Biologics Evaluation and Research, Center for Devices and Radiological Health, and Center for Drug Evaluation and Research--FDA. Final rule.

The Food and Drug Administration (FDA) is amending the regulations for delegations of authority relating to premarket approval of products that are or contain a biologic, a device, or a drug. The amendment grants directors, deputy directors, and certain other supervisory personnel in the Center for Biologics Evaluation and Research (CBER), the Center for Devices and Radiological Health (CDRH), and the Center for Drug Evaluation and Research (CDER) reciprocal premarket approval authority to approve such products.

Biological Products↗

Marketing approval for the lithotripter.

In December 1984, the Food and Drug Administration (FDA) granted Dornier Systems (FRG) approval to market the external shock wave lithotripter (ESWL) in the USA. The Medical Device Amendments of the Food, Drug, and Cosmetic Act require that the FDA evaluate the safety and effectiveness of medical devices intended for commercial distribution in the U.S. Such evaluation includes basic scientific studies, animal testing, and investigational studies in human subjects, culminating in a judgment concerning acceptable risks in terms of anticipated benefits, and whether the device is effective for its intended use. Prior to human studies in West Germany, Dornier had evaluated the destruction of stones of varying composition, measured the rate and energy of stone destruction, and tested blood samples and lymphocyte cultures exposed to shock waves. In addition, studies in both rats and dogs had demonstrated the feasibility of the technique and evidence of safety. Such data are provided by manufacturers when applying for an investigational device exemption (IDE) from the FDA, which permits clinical studies in humans; such studies also require the approval of an Institutional Review Board. The FDA approved Dornier's IDE, allowing human investigational use of the ESWL in facilities in the U.S., conducted concurrently with similar studies in West Germany. Upon completion of clinical trials, data acquired in vitro, in laboratory animals, and in human investigations are submitted to the FDA for a premarked approval application (PMAA). The Agency was given 6 months to make a decision, taking into consideration the recommendation of an advisory panel of experts from outside the Agency who had reviewed the same data. In its evaluation of the ESWL for safety and effectiveness, the FDA considered the question of alternative practices and procedures to treat nephrolithiasis, including percutaneous nephrolithotomy and open surgical procedures, and the adverse effects of such procedures. Clinical data available at the time of review for approval included reports of treatment of 667 patients in West German centers, and 327 patients treated in three U.S. facilities. Dornier and the FDA initiated discussions concerning the labeling of the device and a postmarketing surveillance plan. These were completed and marketing approval for the ESWL was granted.

Costs and Cost Analysis↗

Obstetric and gynecologic devices; reclassification and classification of medical devices used for in vitro fertilization and related assisted reproduction procedures--FDA. Final rule.

The Food and Drug Administration (FDA) is announcing that it is reclassifying instrumentation intended for use in in vitro fertilization (IVF) and related assisted reproduction technology (ART) procedures, including but not limited to gamete intrafallopian transfer (GIFT), embryo transfer (ET), and intracytoplasmic sperm injection (ICSI), from class III (premarket approval) to class II (special controls). FDA is also reclassifying assisted reproduction microscopes and microscope accessories from class III to class I. This reclassification is on the Secretary of the Department of Health and Human Services' (the Secretary's) own initiative based on new information. Accordingly, the order is being codified in the Code of Federal Regulations. Upon the effective date, this Federal Register document may be cited in the absence of an existing predicate device which would be used to support substantial equivalence. Elsewhere in this issue of the Federal Register, FDA is announcing the availability of a draft guidance entitled "Devices Used for In Vitro Fertilization and Related Assisted Reproduction Procedures: Submission Guidance for a 510(k)."

Device Approval↗

Medical devices; reclassification of the cutaneous carbon dioxide and the cutaneous oxygen monitor. Final rule.

The Food and Drug Administration (FDA) is reclassifying the cutaneous carbon dioxide (PcCO2) monitor from class II (performance standards) into class II (special controls). FDA is also reclassifying the cutaneous oxygen (PcO2) monitor for an infant patient who is not under gas anesthesia from class II (performance standards) into class II (special controls) and is reclassifying the cutaneous oxygen (PcO2) monitor for all other uses from class III (premarket approval) into class II (special controls). Elsewhere in this issue of the Federal Register, FDA is announcing the availability of the guidance document entitled "Class II [[Page 76679]] Special Controls Guidance Document: Cutaneous Carbon Dioxide (PcCO2) and Oxygen (PcO2) Monitors; Guidance for Industry and FDA" that will serve as the special control for the devices. These reclassifications are taken on the agency's own initiative based on new information. These actions are being taken under the Federal Food, Drug, and Cosmetic Act (the act), as amended by the Medical Device Amendments of 1976 (the 1976 amendments), the Safe Medical Devices Act of 1990 (the SMDA), the Food and Drug Administration Modernization Act of 1997 (FDAMA), and the Medical Device User Fee and Modernization Act.

Blood Gas Monitoring, Transcutaneous↗

Medical devices: reclassification and codification of the absorbable polydioxanone surgical suture. Final rule.

The Food and Drug Administration (FDA) is announcing that it has issued an order in the form of a letter to Ethicon, Inc., reclassifying the absorbable polydioxanone surgical (PDS) suture intended for use in soft tissue approximation, including use in pediatric cardiovascular tissue where growth is expected to occur and ophthalmic surgery, from class III (premarket approval) to class II (special controls). Elsewhere in this issue of the Federal Register, FDA is announcing the availability of the guidance document entitled "Class II Special Controls Guidance Document: Surgical Sutures; Guidance for Industry and FDA," which is immediately in effect as the special control for the PDS suture, but remains subject to public comment and possible future revision under the agency's good guidance practices. The agency is reclassifying this device into class II because new information supplied by the petitioner indicates that special controls, in addition to general controls, will provide reasonable assurance of the safety and effectiveness of the device, and there is sufficient information to establish special controls. Accordingly, the order is being codified in the Code of Federal Regulations. Any firm submitting a premarket notification (510(k)) for a new PDS suture will need to address the issues covered in the special control guidance. However, the firm need only show that its device meets the recommendations of the guidance or in some other way provides equivalent assurances of safety and effectiveness.

Device Approval↗

The Food and Drug Administration and the regulation of clinical trials for endosseous implants.

The Office of Device Evaluation (ODE), within the Center for Devices and Radiological Health of the Food and Drug Administration is the primary component responsible for the premarket review of medical devices. Dental devices are reviewed by the Dental Devices Branch within ODE. Premarket submissions to FDA for dental endosseous implants should include complete characterization of the device and often may necessitate the inclusion of mechanical and other bench testing and clinical data. FDA guidance documents are available which outline the information that should be included in the submissions. The guidance document for premarket approval submissions for dental endosseous implants also provides guidance on clinical trials for dental implants. This guidance document addresses such issues as the number of patients and study sites, length of follow-up, post-implant assessment, and pooling of data. The review of dental endosseous implants involves many challenging issues, including success/failure criteria, new designs and new indicated uses. The Dental Branch continues to gather information to address these issues.

Clinical Trials as Topic↗

Prosthetic heart valves: Objective Performance Criteria versus randomized clinical trial.

The current Food and Drug Administration (FDA) heart valve guidance document uses an objective performance criteria (OPC) methodology to evaluate the clinical performance of prosthetic heart valves. OPC are essentially historical controls, but they have turned out to be an adequate, and perhaps optimal, study design in this situation. Heart valves have a simple open-and-close mechanism, device effectiveness is easy to document, and the common complications (thromboembolism, thrombosis, bleeding, leak, and infection) are well known and easily detected. Thus, randomized clinical trials (RCTs) have not been deemed necessary for the regulatory approval of prosthetic heart valves. The OPC are derived from the average complication rates of all approved heart valves. Studies based on OPC have been shown to work well; many different valve models have gained FDA market approval based on this methodology. Although heart valve RCTs are not required by the FDA, they have been done to compare valves or treatment regimens after approval. Recently, the Artificial Valve Endocarditis Reduction Trial (AVERT) was designed to compare a new Silzone sewing ring, designed to reduce infection, with the Standard sewing ring on a St. Jude Medical heart valve. This was the largest heart valve RCT ever proposed (4,400 valve patients, followed for as long as 4 years), but it was stopped prematurely because of a high leak rate associated with the Silzone valve. Examining the results showed that a much smaller, OPC-based study with 800 patient-years would have been sufficient to disclose this complication of the Silzone valve.

Bayes Theorem↗

Skin closures using cyanoacrylate tissue adhesives. Plastic Surgery Educational Foundation DATA Committee. Device and Technique Assessment.

Studies have been done and approval is soon possible from the FDA for an octylcyanoacrylate tissue glue for closure of lacerations of incisions. This is a newer-generation cyanoacrylate that improves on the butylcyanoacrylates currently in use in Canada and other countries but not approved by the FDA. It is a pliable, waterproof, film adhesive that can be applied to a laceration and left in place until it disintegrates in 7 to 14 days. It is safe and effective and represents an improvement over the butylcyanoacrylates that have been used for years in many countries. It is not a replacement for sutures but does offer an alternative. Some indications that seem appropriate are for closure of incisions that would be under casts; for simple lacerations in children to avoid the fear of suturing and suture removal; and for closure of incisions or lacerations where it would be a problem for a follow-up visit. This adhesive is less indicated for closure over highly mobile areas such as joints; for areas with usage and friction such as hands or feet; or for areas where exact alignment is a priority, such as the face or eyelids.

Cyanoacrylates↗

Problems in the evaluation of new devices for coronary intervention: what have we learned since 1989?

The objectives of this study are to review the problems associated with the evaluation of new devices, the progress made in that evaluation process since 1989, and the role played by the New Approaches to Coronary Intervention (NACI) registry. In 1988-1989, the first wave of new coronary devices (stents, atherectomy, laser catheters) were entering clinical investigation. It seemed unlikely that the small manufacturer-run registries used to gain approval for earlier balloon catheters would be adequate to evaluate the host of complex new devices, each of which might be used for a restricted set of anatomic indications. Moreover, the wide range of arbitrary definitions then in use for fundamental outcomes (such as success, complication, and restenosis), effectively precluded meaningful device-to-device comparisons. Against this backdrop, the NACI registry was formed with National Heart, Lung, and Blood Institute funding to provide an independent and standardized evaluation of the first 8 new devices under evaluation in the United States, across the broad range of their application. The registry employed a unique modular form set to track the sequence of events during complex cases in which serial new devices and balloon angioplasty might be used, either in a planned way, or an unplanned way (to treat complications or suboptimal results). Outcomes were subjected to standardized criteria for (1) the reason for device use (planned, unplanned); (2) success (device, lesion, and procedural success); (3) complications (a) major (death, Q-wave myocardial infarction, and emergency coronary artery bypass grafting); or (b) other (groin complications, non-wave myocardial infarction, etc.); and (4) clinical restenosis (any subsequent revascularization, target lesion revascularization). Separate funding for an angiographic core laboratory was obtained in 1992, which analyzed 3,936 (88.9%) of the 4,429 films obtained on patients enrolled between November 1990 and March 1994. The NACI registry has addressed a broad range of problems inherent in the evaluation of new devices for coronary intervention. Whereas the approval process has moved progressively towards randomized clinical trials (and away from registries), the NACI registry offers a unique view of current practice, outside the narrow scope of the limited number of randomized trials that have been performed to date. This article shows, however, that we have learned about more than the devices themselves since 1989-we have also learned about the importance of knowing the reason for device use, using precise definitions of endpoint variables, understanding the financial and reimbursement ramifications of new device trials, and upholding strict investigator ethics during the conduct of such evaluations.

Angioplasty↗

Viscosupplementation: therapeutic mechanisms and clinical potential in osteoarthritis of the knee.

Viscosupplementation by means of intra-articular injections of hyaluronic acid has been used to treat osteoarthritis of the knee. The proposed mechanisms of action result from the physical properties of hyaluronic acid, as well as from its anti-inflammatory, anabolic, local analgesic, and chrondroprotective effects. Adverse reactions from hyaluronic acid injections into the knee occurred in 8.3% of the 336 patients treated in one study, but at a rate of less than 3% per injection. Reactions were almost always local and generally resolved over 1 to 2 days. Hyaluronic acid injections were approved by the US Food and Drug Administration as a medical device; thus, the level of efficacy demonstrated is less than might have been required for approval as a drug. Several studies have failed to show statistically significant benefit compared with placebo. Furthermore, the treatment is relatively expensive; the cost of the drug for a series of injections is more than $500 per knee. Therefore, widespread use of these agents should be limited until more convincing data on their efficacy are available from well-designed clinical trials.

Analgesics↗

The control of medical devices in Canada. Canadian Society of Laboratory Technologists.

Medical devices should not be allowed into Canada until they have been approved by a Canadian Regulatory Agency. The approval process should be carried out expeditiously in order to ensure timely availability of medical devices to Canadians, BUT the protection of the public must always be paramount in regulatory decisions. Premarket review of devices should include: a) Testing by the manufacturer to ensure that they operate efficiently b) testing by the manufacturer to validate that they can be operated effectively by the targeted user group(s) c) review of published reports d) investigation of experience with the device in other jurisdictions, through a network of contacts with regulatory agencies in other countries e) if the agency requires it, independent testing of the device should be performed at the expense of the manufacturer Post market surveillance should include: a) adverse incident reporting by health professionals which must be confidential b) review of published reports c) ongoing review of experience with the device in other jurisdictions d) dissemination of adverse experience reports to health care professionals Availability of medical devices should be restricted to situations where they are prescribed and monitored by appropriately-trained health care professionals. The effectiveness of the existing Bureau of Medical Devices should be evaluated. Adequate resources must be provided to a Canadian Regulatory Agency to enable it to ensure that medical devices meet the public's expectations for safety and effectiveness.

Canada↗

Summary recommendations for responsible monitoring and regulation of clinical software systems. American Medical Informatics Association, The Computer-based Patient Record Institute, The Medical Library Association, The Association of Academic Health Science Libraries, The American Health Information Management Association, and The American Nurses Association.

Clinical software systems are becoming ubiquitous. A growing literature documents how these systems can improve health care delivery, but concerns about patient safety must now be formally addressed. In 1996, the U.S. Food and Drug Administration (FDA) called for discussions on regulation of software programs as medical devices. In response, a consortium of organizations dedicated to improving health care through information technology developed recommendations for the responsible regulation and monitoring of clinical software systems by users, vendors, and regulatory agencies. These recommendations were revised and approved by the American Medical informatics Association Public Policy Committee and Board. Other organizations reviewed, modified, and approved the recommendations, and the Boards of Directors of most of the organizations in the consortium endorsed the guidelines. The consortium proposes four categories of clinical system risk and four classes of monitoring and regulatory action that can be applied on the basis of the risk level. The consortium recommends that most clinical software systems be supervised locally and that developers of health care information systems adopt a code of good business practices. Budgetary and other constraints limit the type and number of systems that the FDA can regulate effectively; therefore, the FDA should exempt most clinical software systems and focus on systems that pose high clinical risk and provide limited opportunity for competent human intervention.

Clinical Medicine↗

Update of carotid stent trials.

As is the case in many vascular territories, endovascular treatment of extracranial carotid artery disease is becoming a rival alternative to surgery. Results of carotid artery stenting (CAS) are improving with the introduction of embolic protection devices, improved technology, and increasing operator experience. Multiple clinical studies have shown results in favor of CAS as opposed to carotid endarterectomy (CEA) in patients considered at high risk for surgery. Current ongoing trials are examining both treatment options in low and intermediate risk patients in prospective randomized protocols. With the recent FDA approval of carotid stent systems, we are entering a new era in the treatment of carotid artery disease. An update of modern carotid stent studies, as well as stent versus surgery studies in the current era is needed.

Blood Vessel Prosthesis Implantation↗

Direct intrauterine sampling: the IUMC Endometrial Sampler.

Endometrial cytology has been studied for more than 25 years, and a variety of cytologic devices have been developed for direct sampling of the endometrium. The quality of endometrial samples procured by various devices is markedly different and greatly affects the diagnostic accuracy. A new endometrial sampling device, the IUMC Endometrial Sampler, was developed at the Indiana University Medical Center and approved by the Food and Drug Administration for general medical use. This device is intended for the early detection of endometrial carcinoma and its precursors. It can be used to monitor the endometrial condition of patients receiving estrogen replacement therapy or tamoxifen. It is also useful for the procurement of uncontaminated endometrial samples for microbiologic studies from patients with suspected endometritis. It has the potential to be used for endometrial dating for patients with infertility disorders. In our clinical trials and sampling tests using hysterectomy specimens, adequate and representative endometrial samples without contamination from endocervix and vagina were consistently obtained by this device. The procedure of endometrial sampling using this device and the preparation techniques for endometrial brushing specimens are discussed and illustrated.

Adenocarcinoma↗

Frameless intra-uterine contraceptive device (GyneFix).

Modern copper-containing contraceptive intra-uterine devices (IUDs) typically comprise a solid plastic frame loaded with copper wire and/or copper sleeves. Although they are very effective (annual pregnancy rates generally below 1%), some women discontinue their use within a year after insertion because of excessive bleeding and/or painful periods (4-15%), or because the device has been spontaneously expelled (2-8%). GyneFix (Contrel) is a new IUD approved for up to 5 years of use. Its manufacturer claims that the device produces fewer unwanted effects, and is less likely to be expelled, than conventional IUDs because it does not have a plastic frame (a frameless device). Here we assess these claims.

Costs and Cost Analysis↗