Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Compressive Strength”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94Linked to original sources

Biomechanical investigation of different internal fixations in medial opening-wedge high tibial osteotomy.

BACKGROUND: The medial opening-wedge osteotomy for treatment of varus gonarthritis has become very popular in recent years. Different implants for internal fixation after the osteotomy have been created. It is still unclear, which principle of internal fixation (angle stable or non-angle-stable plate with or without spacer) has the best biomechanical properties. The aim of this study was to determine the biomechanical properties of different fixation techniques in medial opening-wedge high tibial osteotomy in a porcine bone model. METHODS: A 10-mm high tibial opening-wedge osteotomy was performed and stabilized with plates of similar dimensions but different functional principle (conventional plate, angle stable plate with or without spacer). Biomechanical properties (stiffness, displacement within the osteotomy space and load at failure) were evaluated under axial load. RESULTS: Plates which contain a spacer had a significantly higher stiffness at a load at 1000 N (p < 0.05). This correlates with a significantly reduced deformation within the osteotomy space. The strength at failure was not different between the groups. The use of a spacer in a conventional plate produces fractures of the lateral tibial cortex. In angle stable plates and plates containing spacers, the failure was caused by fractures of the lateral tibia surface, the fibula or by displacement within the tibio-fibular joint. The failure was caused primarily by implant insufficiency in plates without spacers. CONCLUSIONS: In a model with comparable conditions, implants which contain a spacer have superior biomechanical properties. Angle stable plates may prevent fractures of the lateral cortex after opening-wedge osteotomy.

Animals↗

Mechanical properties of femoral diaphysis and femoral neck of female rats chronically exposed to various levels of cadmium.

The effect of chronic exposure to cadmium (Cd) on the mechanical properties of femoral diaphysis and femoral neck was investigated on a rat model of human exposure. Three-week-old female Wistar rats were exposed to Cd in drinking water at concentrations of 1, 5, 50, or 100 mg/L for 12 months. Biomechanical properties of the femoral diaphysis were evaluated in a three-point bending test and those of the femoral neck in a bending test with vertical loading of the head. Bone mineral content (BMC) and bone mineral density (BMD) at the whole femur, and BMD at the diaphysis and proximal femur (head and neck region) of the Cd-treated rats decreased in a dose-dependent manner, except for the diaphyseal BMD at a Cd concentration of 1 mg/L. Exposure to Cd concentrations of 1 and 5 mg/L had only little effect on the diaphyseal mechanical properties (decreased yield load with unchanged bending strength, stiffness, yield stress, ultimate stress, and Young modulus), whereas the bending strength and stiffness of the neck decreased and the yield load clearly tended to decline or declined. The effect of Cd at the two locations was more marked in the 50 and 100 mg/L groups, and changes in the bone geometry were observed in these animals. The results clearly revealed that chronic, even low-level, exposure to Cd results in demineralization and weakening of the femur. The femoral neck seems to be more vulnerable than the diaphysis to failure from Cd. We conclude that environmental exposure to Cd may be an important risk factor for femoral neck fracture.

Absorptiometry, Photon↗

Dietary xylitol supplementation prevents osteoporotic changes in streptozotocin-diabetic rats.

The effects of 10% and 20% dietary xylitol supplementation on the biomechanical properties, trabeculation, and mineral content of long bones were studied in streptozotocin-diabetic rats. Forty 3-month-old male Wistar rats were divided randomly into four groups of 10. Rats in three groups were administered a single injection of streptozotocin (50 mg/kg body weight) to induce type I diabetes, while animals in the fourth group were given a sham injection of physiological saline. The sham-injected group and one of the streptozotocin-diabetic groups were fed the basal diet, while the two diabetic groups were fed the same diet supplemented with 10% and 20% xylitol (wt/wt). After 3 months, the rats were killed and the long bones were prepared for analysis. The 10% and 20% dietary xylitol supplementation significantly prevented the type I diabetes-induced decrease in the mechanical stress resistance of the tibia in the three-point bending test, the shear stress of the femur in the torsion test, and the stress resistance of the femoral neck in the loading test. No statistically significant differences were found between any groups in the values for strain or Young's modulus in the three-point bending test, or in the values for the shear modulus of elasticity in the torsion test. These findings indicate that dietary xylitol protects against the weakening of the bone strength properties of both cortical and trabecular bone without affecting the elastic-plastic properties. Supplementation with 10% and 20% dietary xylitol significantly prevented the type I diabetes-induced decrease of humeral ash weight and tibial density. Histomorphometric data for the secondary spongiosa of the proximal tibia showed that 10% and 20% dietary xylitol supplementation also significantly prevented the type I diabetes-induced loss of trabecular bone volume. In conclusion, dietary xylitol supplementation protects against the weakening of bone biomechanical properties in streptozotocin-diabetic rats. This is related to the preserved bone mineral content and preserved trabecular bone volume.

Animals↗

Mechanical properties and wear behavior of light-cured packable composite resins.

OBJECTIVES: Determination of flexural strength, flexural modulus, fracture toughness and wear resistance of three packable composites (Solitaire, Surefil, ALERT) and a packable ormocer (Definite) in comparison with an advanced hybrid composite (Tetric Ceram) and an ion-releasing composite (Ariston pHc). METHODS: Flexural strength, flexural modulus and fracture toughness of each material were determined in three-point bending (each test n = 10). Single-edge notched-bend specimens were used to evaluate the fracture toughness (K1C). Wear of the materials (n = 8) was determined in a pin-on-block-design with a spherical Degusit antagonist at 50 N vertical load and quantified by a replica technique using a 3D-laser scanner. Replicas were made after 6000, 10,000, 30,000 and 50,000 load cycles. The mean wear rate (MWR (micron 3 cycle-1)) was obtained by a linear regression analysis in the steady-state of the time-wear-curve. All results were statistically analyzed with ANOVA and post hoc Tukey HSD tests (p < 0.05). RESULTS: ALERT exhibited the highest flexural modulus (12.5 +/- 2.1 GPa) and K1C (2.3 +/- 0.2 MN m-3/2), but the lowest wear resistance (8275 micron 3 cycle-1). Solitaire presented the highest wear resistance (1591 micron 3 cycle-1), but significantly lower flexural strength (81.6 +/- 10.0 MPa), flexural modulus (4.4 +/- 0.3 GPa), and K1C (1.4 +/- 0.2 MN m-3/2) than all other materials. Surefil revealed a significantly higher flexural modulus (9.3 +/- 0.9 GPa) and wear resistance (3028 micron 3 cycle-1) than Tetric Ceram (6.8 +/- 0.5 GPa; 5417 micron 3 cycle-1) and Ariston pHc (7.3 +/- 0.8 GPa; 7194 micron 3 cycle-1). SIGNIFICANCE: The tested packable composite resins differed significantly in their mechanical properties. This study suggested that fracture and wear behavior of the composite resins are highly influenced by the filler system. Overall, Surefil demonstrated good fracture mechanics parameters and a low wear rate.

Analysis of Variance↗

The effect of processing on the structural characteristics of vancomycin-loaded amorphous calcium phosphate matrices.

Calcium polyphosphate antibiotic delivery matrices were prepared using a unique processing technique involving the exposure of calcium polyphosphate pastes to high humidity for 0, 5, 24 or 48 h to induce gelling. Subsequently, samples were dried for a minimum of 24 h. The mild conditions associated with matrix fabrication readily allowed for vancomycin incorporation within an environment that did not disrupt antibiotic activity. While reproducible from a processing standpoint, the gelling and drying process did contribute to a decrease in matrix tensile strength and the formation of significant pores near the surface of the matrices. Generally, the core of the gelled matrices appeared to be denser than their non-gelled counterparts. The degree of phosphate chain lysis during the gelling and drying stages was quantified using solution 31P nuclear magnetic resonance (NMR) spectroscopy. Both NMR and Raman spectroscopy indicated that the presence of vancomycin did not appreciably alter the matrix formation process. The ability to incorporate clinically relevant levels of antibiotic within this degradable bone substitute matrix suggests the potential of this approach for creating a localized antibiotic delivery system to treat osteomyelitis infections.

Anti-Bacterial Agents↗

[Study of shearing strength between layers of light curing composite Esterfill PHOTO].

There was determined shearing strength of monolit samples of light curing material and samples received by modeling of further layers on surfaces with and without inhibited layer and also tensile strength of layers connected with the help of light curing adhesive. The study was performed on enamel, dentine and cutting edge masses from set of light curing material Esterfill PHOTO for prosthetic purposes. The received results showed that shearing strength between layers of enamel, dentine and cutting edge masses of Esterfill PHOTO varied between 22 and 28 MPa and tensile force divided by the nominal surface area did not depend upon the way of sample modeling. Distraction zone represented half of the cone turn out of substrate. More rigid material chopped in the process of distraction lesser volume off substrate. For prosthetic purposes it was recommended to use the equipment allowing to combine the final photopolymerization of the article with annealing under high temperature conditions or make annealing of the ready article after photopolymerization.

Adhesiveness↗

Cyclic loading alters biomechanical properties and secretion of PGE2 and NO from tendon explants.

BACKGROUND: Tendon overuse injuries are a common occurrence; accounting for a large proportion of occupational and athletic injuries. The concept examined in this study is the role of load-induced intrinsic inflammation to the mechanism of these injuries. This study examined the influence of cyclical loading on the mechanical properties, cell viability, and inflammatory mediators of cultured tendon explants. METHODS: Chicken digital flexor tendon explants were isolated and separated into no-load (24 h rest), moderate load (0.25-3.0 MPa, 1 Hz, 4 h, 20 h rest), and aggressive load (0.25-12.0 MPa, 1 Hz, 24 h) treatment groups. Tissue loading was carried out with a pneumatic device under load-control. The loading regimens for each explant treatment group started at a uniform time point (day 3 from isolation, t = 0 h). Medium was collected at t = 24 and t = 48 h and analyzed for the inflammatory mediators prostaglandin E(2) and nitric oxide. Viability was evaluated at t = 48 h. FINDINGS: Biomechanical data revealed a significantly (P < 0.05) lower strength in the aggressively loaded specimens compared to the moderately loaded samples. Prostaglandin E(2) concentrations of aggressively loaded samples showed significantly higher values compared to moderately loaded samples at t = 48 h. Nitric oxide concentrations were greater in the moderately loaded samples relative to the no-load group at t = 24 h. Viability was not found to differ among the groups. INTERPRETATION: Alterations in cyclical loading of tendon may cause a change in fibroblast-mediated inflammatory mediator production in tendon. This response is of clinical significance as it may have a role in the pathology of tendon overuse injuries.

Adaptation, Physiological↗

Development of supporting materials for microbial immobilization and iron oxidation.

We developed the microbial immobilization particle with curdlan and activated carbon, which has great adsorption capacity. The characteristics of porosity and mechanical strength of these supporting particles are dependent on manufacturing method. The supporting particle showed the best performance when the ratio of curdlan and activated carbon was 30 to 6 g/L. Brumauer-Emmett-Teller (specific surface area) and swelling capacity of the carrier were 52.63 m2/g and 17 (w/w), respectively. The immobilization characteristics of iron-oxidizing bacteria on supporting particles were observed using a scanning electron microscope. The concentration of microorganism on the surface of supporting particle was increased with reaction time. As the number of iron oxidation batch cycles increased, the iron oxidation rate increased.

Bacterial Adhesion↗

Serum albumin-alginate coated beads: mechanical properties and stability.

According to a previously described method, alginate beads were prepared from a Na-alginate solution containing propylene glycol alginate (PGA) and human serum albumin (HSA). The solution was added dropwise to a CaCl2 solution. The beads were treated with NaOH, which started the formation of amide bonds between HSA and PGA at the periphery, giving a membrane. Batches of beads with increasingly thick membranes were prepared using growing concentrations of NaOH, and studied with a texture analyser. When raising NaOH concentration, the rupture strength progressively increased, and the resistance strength to a deformation of 50% of total height also increased before slightly decreasing for the highest NaOH concentration. Variations of bead elasticity were also observed. When the beads were prepared with saline reducing gelation time from 10 to 5 min, and reaction time from 15 to 5 min, mechanical properties varied more progressively with the NaOH concentration, while the results became more reproducible. A series of assays conducted with 0.01 M NaOH confirmed the importance of using a short gelation time, and saline rather than water. Stability assays were also performed. The results were compared to those of alginate-polylysine coated beads and showed the interest of the transacylation method.

Alginates↗

A new selective estrogen receptor modulator, CHF 4227.01, preserves bone mass and microarchitecture in ovariectomized rats.

UNLABELLED: A new SERM, CHF 4227.01, given to 6-month-old female rats immediately after ovariectomy, preserved bone mass and bone microarchitecture without affecting uterus weight. It also decreased serum cholesterol and fat mass in estrogen-deficient rats. INTRODUCTION: We tested the effect of a new benzopyran derivative, CHF 4227.01, with selective estrogen receptor modulator (SERM) activity on bone mass and biomechanics in ovariectomized (OVX) female rats in comparison with 17alpha-ethinylestradiol (EST), raloxifene (RLX), and lasofoxifene (LFX). MATERIALS AND METHODS: Four doses of CHF 4227.01 (0.001, 0.01, 0.1, and 1 mg/kg body weight [bw]/day) were administered in OVX animals daily by gavage 5 days/week for 4 months. EST was administered at a dose of 0.1 mg/kg bw/day, whereas RLX and LSX were administered at doses of 1 and 0.1 mg/kg bw/day, respectively, by gavage. In one group (Sham), rats were operated but the ovaries not removed; another OVX group was treated only with placebo. RESULTS AND CONCLUSIONS: Treatment with CHF 4227.01 (1.0 and 0.1 mg/kg bw), EST (0.1 mg/kg bw), LFX (0.1 mg/kg bw), or RLX (1.0 mg/kg bw) prevented bone loss on the lumbar spine and the proximal femur assessed in vivo by DXA. Volumetric BMD obtained by pQCT ex vivo confirmed protection from bone loss in the spine and proximal femur among rats treated with CHF 4227.01. This effect was associated with strong inhibition of bone resorption both histologically and biochemically. Furthermore, CHF 4227.01 preserved trabecular microarchitecture, analyzed by muCT, and maintained biomechanical indices of bone strength in the spine and proximal femur, effects also observed for RLX, whereas LSX was less protective of microarchitecture. CHF 4227.01 treatment did not affect uterine weight, prevented the increase in body weight and fat mass seen in OVX animals, and decreased serum cholesterol to below the average of intact animals. In conclusion, CHF 4227.01 exhibits a promising therapeutic and safety profile as a new SERM on both skeletal and extraskeletal outcomes.

Absorptiometry, Photon↗

Effects of sintering temperature over 1,300 degrees C on the physical and compositional properties of porous hydroxyapatite foam.

Porous hydroxyapatite (HAP) foam permits three-dimensional (3D) structure with fully interconnecting pores as well as excellent tissue response and good osteoconductivity. It is therefore thought to be a good candidate as scaffold material for bone regeneration and as a synthetic bone substitute material. To fabricate better porous HAP foam, improved physical and structural properties as well as higher osteoconductivity are desired. In the present study, the effects of sintering temperature on the physical and compositional properties of porous HAP foam were evaluated by employing high sintering temperature starting at 1,300 degrees C up to 1,550 degrees C. The mechanical strength of porous HAP foam increased with sintering temperature to reach the maximum value at 1,525 degrees C, then decreased slightly when sintering temperature was further increased to 1,550 degrees C. Alpha tricalcium phosphate (alpha-TCP) was formed, and thus the porous HAP foam became biphasic calcium phosphate. Biphasic calcium phosphate consisting of both alpha-TCP and HAP had been reported to show higher osteoconductivity than HAP alone. We therefore recommend 1,500-1,550 degrees C as the sintering temperature for porous HAP foam since this condition provided the most desirable physical properties with biphasic calcium phosphate composition.

Analysis of Variance↗

A comparison of pedicle and lateral mass screw construct stiffnesses at the cervicothoracic junction: a biomechanical study.

STUDY DESIGN: Biomechanical comparison of five different posterior cervicothoracic junction (C7-T1) fixation constructs in a cadaveric model. OBJECTIVES: To determine whether augmenting C7 lateral mass screws with spinous process wires or additional fixation in the C6 lateral mass can create constructs of similar normalized stiffness to that of C7 pedicle screws. SUMMARY OF BACKGROUND DATA: Cervical pedicle screws are known to provide excellent fixation but are potentially dangerous and technically demanding to insert. Lateral mass screws are safer and easier to insert but have less pullout strength and must often be short at C7. METHODS: Twelve cadaveric cervicothoracic specimens (C5-T2) were randomly assigned to one of three experiments: Experiment A (Part 1 and Part 2), Experiment B, and Experiment C (Part 1 and Part 2) (n = 4 each for each experiment). First, the intact specimens were biomechanically tested according to a seven-part loading protocol. The specimens were then destabilized, and then restabilized with the following constructs in conjunction with bilateral T1 pedicle screws and biomechanically tested again using the same seven-part biomechanical protocol as was applied to the intact specimens. Experiment A: Part 1: lateral mass screw fixation at C7 (C7LM); then Part 2: retested after augmentation with triple wiring (C7LM+W). Experiment B: pedicle screw fixation at C7 (C7PS). Experiment C: Part 1: C6 and C7 lateral mass screws (C6C7LM); then Part 2: retested after augmentation with triple wiring (C6C7LM+W). Thus, five different constructs were biomechanically compared in these three experiments. RESULTS: None of the lateral mass constructs demonstrated a significant increase in normalized stiffness when augmented with wiring in any mode of testing. In axial compression, the C7PS construct showed significantly higher (P < 0.001) normalized stiffness than any of the other four constructs. In extension, there were no significant differences among any of the five constructs. Inflexion, right/left lateral bending and right/left axial torsion, the C7PS construct again showed significantly higher normalized stiffness (P < 0.05) than lateral mass fixation at C7 alone. However, in these five modes of testing, the addition of a secondary point of lateral mass fixation at C6 (C6C7LM) produced a construct with a normalized stiffness similar to that of C7PS with no significant difference (P > 0.05). CONCLUSION: C7 pedicle screw fixation provides the construct with the highest normalized stiffness for stabilizing the cervicothoracic junction. If C7 pedicle fixation is not possible, then performing two-level lateral mass fixation at C6 and C7 will achieve a construct with similar normalized stiffness except in axial compression. The addition of triple wiring to the spinous processes does not significantly increase lateral mass construct normalized stiffness.

Aged↗

Partial coverage restoration systems on molars--comparison of failure load after exposure to a mastication simulator.

This in vitro study evaluated the failure load of partial coverage restorations (PCR) made of various materials cemented on natural molars after exposure to the mastication simulator. Sixty-four maxillary molars were divided into four groups of 16 test specimens each. The specimens in one group remained unprepared (group NP); the teeth in the other groups were prepared equally according to standardized guidelines and restored with the following PCR: Group GO (Gold-Pontor-MPF; Metaux Precieux SA, Metalor, Neuchatel, Switzerland), group TA (Targis; Ivoclar Vivadent AG, Schaan, Liechtenstein) and group EM (IPS-Empress; Ivoclar Vivadent AG). The restorations in group GO were cemented conventionally, while those in groups TA and EM were luted adhesively. Groups NP and GO served as control groups. All test specimens were subjected to 1.2 million cycles (F = 49 N) in a mastication simulator. Subsequently, all test specimens were loaded occlusally until fracture occurred using an universal testing machine. All specimens withstood the masticating simulation. The median (IQR = x(0.25)-x(0.75)) failure loads were as follows: group NP: 1960.3(1480.5-2227.5) N, group TA: 1478.6(1293.4-1856.7) N and group EM: 1400.1(1043.1-1721.6) N. All test specimens of group GO achieved fracture strength values which exceeded a fracture load of 5500 N. The values of group GO were statistically significantly higher than those of groups NP, TA and EM (P < 0.00001). Furthermore, the results of group NP were significantly higher (P = 0.0226) than those of group EM. The results of groups NP and TA (P = 0.2022) as well as of groups TA and EM (P = 0.5340) did not differ significantly. The median values of all PCR systems obtained were within the limits of clinical acceptance. Long-term clinical investigations which take additional parameters into consideration are required before the composite-based Targis(R) (Ivoclar Vivadent AG) material can be recommended for indirect PCR.

Compressive Strength↗

The effects of improved strength on obstacle negotiation in community-living older adults.

Poor mobility has been associated with age-related deterioration in muscle strength. While previous work has examined the effects of improved strength on level walking, we have quantified the effects of a resistance-training program on obstructed gait tasks using biomechanical-dependent measures. Forty-five community-dwelling participants aged 62 years or older were randomised to either a control (n=16) or experimental group (n=29). The experimental subjects exercised for 24 weeks on a progressive resistance-training program designed to improve lower body strength. Dynamic strength was assessed at weeks 0 and 24 as well as specific laboratory gait kinetics and kinematics during stepping over an obstacle and negotiation of a raised surface set at 10, 20 and 30% of each subject's leg length. Significant strength improvements (P<0.05), ranging between 197 and 285%, were recorded in the experimental group. The strength gains in the experimental group were accompanied by significant increases in obstacle-crossing stride velocity (range 5.5-15.5%) due to increases in stride length and decreases in stride duration for both gait tasks. Significant changes in the peak vertical and anterior-posterior ground reaction forces as well as in kinematic variables associated with a safe obstacle traverse such as vertical obstacle heel clearance, limb flexion at obstacle crossing, horizontal foot placement and vertical landing velocity resulted in an improved crossing strategy in the experimental subjects. These findings provide evidence of significant improvements in obstructed gait function of community-living older adults associated with a systematic resistance-training program.

Age Factors↗

Fixation of segmental subtrochanteric fractures. A biomechanical study.

Segmental subtrochanteric fractures have been associated with high rates of malunion, nonunion, and implant failure. Although the use of second generation intramedullary nails with proximal interlocking in the femoral head has been advocated for these fractures, shaft fractures at the tip of short second generation intramedullary rod nails in clinical studies raise concerns about the mechanical suitability of these implants. No biomechanical data are available on the strength of fixation and mode of failure of these newer implants. This study compares the strength and failure mode of segmental subtrochanteric fractures stabilized with 3 current implants. Eighteen anatomic specimen femurs were obtained. The 3 implants tested were the Russell-Taylor reconstruction nail, a short intramedullary hip screw, and a long intramedullary hip screw. Each femur was instrumented and a segmental subtrochanteric fracture was created. The femurs were loaded in a Materials Testing System. The strength of the reconstruction nail group (2869 +/- 210 N) was significantly greater than for the short intramedullary rod hip screw (2330 +/- 490 N), and the long intramedullary rod hip screw (2181 +/- 244 N). The failure modes for the implants were: screw cut out of the femoral head for the reconstruction nail; fracture of the femoral shaft for the short intramedullary hip screw, and implant bending for the long intramedullary hip screw. This study suggests that the reconstruction nail is the superior implant for segmental subtrochanteric fractures of those tested. Implant bending and shaft fractures at lower loads make the 2 intramedullary rod hip screw implants less suitable.

Aged↗

Utilization of industrial by-products for the production of controlled low strength materials (CLSM).

Industrial by-products were used for the production of controlled low-strength material (CLSM). CLSM, also known as 'flowable fill' is used as a replacement of compacted soil in cases where the application of the latter is difficult or impossible. The low mechanical requirements (compared with structural concrete) enable the use of industrial by-products for the production of CLSM. In this study cement kiln dust, asphalt dust, coal fly ash, coal bottom ash and quarry waste were tested for the possibility of producing CLSM with large proportions of those wastes. The results showed that in most cases, CLSM with good properties could be made with significant amounts of dust (25-50%w), especially when the dust has some cementing or pozzolanic potential as do fly ash and cement kiln dust.

Carbon↗

High density polyetherurethane foam as a fragmentation and radiographic surrogate for cortical bone.

BACKGROUND: Although one of the most important factors in predicting outcome of articular fracture, the comminution of the fracture is only subjectively assessed. To facilitate development of objective, quantitative measures of comminution phenomena, there is need for a bone fragmentation surrogate. METHODS: Laboratory investigation was undertaken to develop and characterize a novel synthetic material capable of emulating the fragmentation and radiographic behavior of human cortical bone. RESULT: Screening tests performed with a drop tower apparatus identified high-density polyetherurethane foam as having suitable fragmentation properties. The material's impact behavior and its quasi-static mechanical properties are here described. Dispersal of barium sulfate (BaSO4) in the resin achieved radio-density closely resembling that of bone, without detectably altering mechanical behavior. The surrogate material's ultimate strength, elastic modulus, and quasi-static toughness are within an order of magnitude of those of mammalian cortical bone. The spectrum of comminution patterns produced by this material when impacted with varying amounts of energy is very comparable to the spectrum of bone fragment comminution seen clinically. CONCLUSIONS: A novel high-density polyetherurethane foam, when subjected to impact loading, sustains comminuted fracture in a manner strikingly similar to cortical bone. Moreover, since the material also can be doped with radio-opacifier so as to closely emulate bone's radiographic signature, it opens many new possibilities for CT-based systematic study of comminution phenomena.

Barium Sulfate↗

Effects of neurectomy and tenotomy on the bone mineral density and strength of tibiae.

The right hindlimbs of 5 or 6-week old Wistar male rats were sciatic/femoral neurectomized, tenotomized or sham operated. The rats were sacrificed 2 weeks after the surgery and the tibiae were removed. pQCT measurement was performed on total, cortical, and trabecular bone separately at different regions. Reduction of the bone mineral density by unloading was observed more significantly at metaphysis than at diaphysis due to histological heterogeneity between metaphysis and diaphysis; metaphysis is rich in trabecular bone and diaphysis is abundant in cortical bone. Trabecular bone might be more sensitive to unloading because the reduction rate of volumetric bone mineral density in trabecular bone was approximately 10 times and 3 times larger than that of cortical bone in both neurectomy and tenotomy rats, respectively, Unloading also reduced the cross-sectional area and stress strain index at metaphysis.

Absorptiometry, Photon↗