Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “CLAMPS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94Linked to original sources

Comparison of RNase A, a chemical cleavage and GC-clamped denaturing gradient gel electrophoresis for the detection of mutations in exon 9 of the human acid beta-glucosidase gene.

Gaucher disease (GD), which results from mutations in the human acid beta-glucosidase (beta-Glc) gene, was used as a model system to compare the utility of three methods capable of detecting single base substitutions. PCR-amplified beta-Glc exon 9 sequences of GD patients were screened for single base mutations by GC-clamped denaturing gradient gel electrophoresis (DGGE) and RNase A cleavage of RNA-DNA heteroduplexes, and by chemical (hydroxylamine/osmium tetroxide) cleavage of dsDNA heteroduplexes. PCR products showing abnormal behaviour were cloned and sequenced. Three new point mutations were detected by this strategy. A G to C (Asp409 to His409) substitution was present in two Type 1 and one Type 3 GD patients; an A to T transversion (Asp409 to Val409) was detected in only a single Type 3 individual, and a G to T mutation (Val394 to Leu394) was present in one Type 1 and one Type 3 patient. GD thus exhibits extensive molecular heterogeneity, with at least five single base mutations in beta-Glc exon 9. In every case verified by ASO hybridization, DGGE had correctly identified the presence of the three new mutations, as well as the two previously described exon 9 mutations. In comparison, although RNase A and the chemical method were both able to detect some of these mutations, neither method reproducibly detected all of them. Additionally, DGGE was the only method that was able to reliably determine whether a given mutation was present homozygously or heterozygously. These results suggest that GC-clamped DGGE may be a more reliable and informative screening method for point mutation detection.

Base Composition↗

The 'helix clamp' in HIV-1 reverse transcriptase: a new nucleic acid binding motif common in nucleic acid polymerases.

Amino acid sequences homologous to 259KLVGKL (X)16KLLR284 of human immunodeficiency virus type 1 reverse transcriptase (HIV-1 RT) are conserved in several nucleotide polymerizing enzymes. This amino acid motif has been identified in the crystal structure model as an element of the enzyme's nucleic acid binding apparatus. It is part of the helix-turn-helix structure, alpha H-turn-alpha I, within the 'thumb' region of HIV-1 RT. The motif grasps the complexed nucleic acid at one side. Molecular modeling studies on HIV-1 RT in complex with a nucleic acid fragment suggest that the motif has binding function in the p66 subunit as well as in the p51 subunit, acting as a kind of 'helix clamp'. Given its wide distribution within the nucleic acid polymerases, the helix clamp motif is assumed to be a structure of general significance for nucleic acid binding.

Algorithms↗

Probing the role of the ATP-operated clamp in the strand-passage reaction of DNA gyrase.

The high-resolution structure of the 43 kDa N-terminal fragment of the DNA gyrase B protein shows a large cavity within the protein dimer. The approximate size of this cavity is 20 A, suggesting it could accommodate a DNA helix. Computer-modelling studies of this cavity suggest that it contains a constriction, reducing the width to approximately 13 A, principally caused by the side chain of Arg286. We have used site-directed mutagenesis to alter this residue to Gln. Gyrase bearing this mutation shows virtually no supercoiling activity and near-normal relaxation and DNA cleavage activities. The mutated protein has ATPase activity which cannot be stimulated by DNA. These data support the proposed role of the 43 kDa domain as an ATP-operated clamp which binds DNA during the supercoiling cycle. The lack of DNA-dependent ATPase of the mutant may indicate that binding of DNA within the clamp is a prerequisite for stimulation of the ATPase activity.

Adenosine Triphosphatases↗

The N-terminus of Mcm10 is important for interaction with the 9-1-1 clamp and in resistance to DNA damage.

Accurate replication of the genome requires the evolutionarily conserved minichromosome maintenance protein, Mcm10. Although the details of the precise role of Mcm10 in DNA replication are still debated, it interacts with the Mcm2-7 core helicase, the lagging strand polymerase, DNA polymerase-α and the replication clamp, proliferating cell nuclear antigen. Loss of these interactions caused by the depletion of Mcm10 leads to chromosome breakage and cell cycle checkpoint activation. However, whether Mcm10 has an active role in DNA damage prevention is unknown. Here, we present data that establish a novel role of the N-terminus of Mcm10 in resisting DNA damage. We show that Mcm10 interacts with the Mec3 subunit of the 9-1-1 clamp in response to replication stress evoked by UV irradiation or nucleotide shortage. We map the interaction domain with Mec3 within the N-terminal region of Mcm10 and demonstrate that its truncation causes UV light sensitivity. This sensitivity is not further enhanced by a deletion of MEC3, arguing that MCM10 and MEC3 operate in the same pathway. Since Rad53 phosphorylation in response to UV light appears to be normal in N-terminally truncated mcm10 mutants, we propose that Mcm10 may have a role in replication fork restart or DNA repair.

Cell Cycle Proteins↗

Neuroanesthesia adjunct therapy (mannitol and hyperventilation) is as effective as cerebrospinal fluid drainage for prevention of paraplegia after descending thoracic aortic cross-clamping in the dog.

We compared cerebrospinal fluid (CSF) drainage (Group D; n = 8) to neuroanesthesia adjunct therapy (hyperventilation and mannitol administration; Group N; n = 8) for the prevention of paraplegia using a canine model of descending thoracic aortic cross-clamping (AXC; 2.5 mm distal to the left subclavian artery for 30 min). We expected no difference in neurologic outcome between groups. After surgical preparation and a 30-min stabilization period, dogs in Group D had CSF drained prior to application of the AXC. During the period of AXC, CSF was allowed to drain freely in an attempt to have cerebrospinal fluid pressure (CSFP) no greater than central venous pressure (CVP). Dogs in Group N were hyperventilated (PaCO2 28-32 mm Hg) and received 2 g/kg of mannitol prior to AXC and then 1 g.kg-1.hr-1 during clamping. Systemic hemodynamics, CSFP, and arterial blood gases were measured at 1) baseline, 2) 2 min after AXC, 3) 20 min after AXC, 4) 5 min after AXC release, and 5) 30 min after resuscitation. With release of the AXC, PaCO2 was not controlled in Group D; in Group N the minute ventilation was further increased to maintain PaCO2 constant. At precisely 24 h after AXC, the animals were assessed for incidence and severity of paraplegia, using the Tarlov score, by an observer unaware of the experimental protocol. The animals were then killed, and the entire spinal cord was removed for histologic assessment. Multiple sections of the lumbar spinal cord were processed and stained with hematoxylin and eosin, then examined by light microscopy for nonviable neurons in the anterior spinal cord.(ABSTRACT TRUNCATED AT 250 WORDS)

Anesthesia↗

Portal triad clamping or hepatic vascular exclusion for major liver resection. A controlled study.

OBJECTIVE: The authors compared operative course of patients undergoing major liver resections under portal triad clamping (PTC) or under hepatic vascular exclusion (HVE). SUMMARY BACKGROUND DATA: Reduced blood loss during liver resection is achieved by PTC or HVE. Specific complications and postoperative hepatocellular injury mediated with two procedures have not been compared. METHODS: Fifty-two noncirrhotic patients undergoing major liver resections were included in a prospective randomized study comparing both the intraoperative and postoperative courses under PTC (n = 24) or under HVE (n = 28). RESULTS: The two groups were similar at entry, but eight patients were crossed over to the other group during resection. In the HVE group, hemodynamic intolerance occurred in four (14%) patients. In the PTC group, pedicular clamping was not efficient in four patients, including three with involvement of the cavohepatic intersection and one with persistent bleeding due to tricuspid insufficiency. Intraoperative blood losses and postoperative enzyme level reflecting hepatocellular injury were similar in the two groups. Mean operative duration and mean clampage duration were significantly increased after HVE. Postoperative abdominal collections and pulmonary complications were 2.5-fold higher after HVE but without statistical significance, whereas the mean length of postoperative hospital stay was longer after HVE. CONCLUSIONS: This study shows that both methods of vascular occlusion are equally effective in reducing blood loss in major liver resections. The HVE is associated with unpredictable hemodynamic intolerance, increased postoperative complications with a longer hospital stay, and should be restricted to lesions involving the cavo-hepatic intersection.

Adolescent↗

Thoracoabdominal aneurysm repair: perspectives over a decade with the clamp-and-sew technique.

OBJECTIVES: Experience over a decade with thoracoabdominal aortic aneurysm (TAA) repair using a clamp-sew technique was reviewed to compare overall results with alternative operative methods. SUMMARY BACKGROUND DATA: Controversy continues as to the optimal technique for TAA repair, with frequent contemporary emphasis on bypass-distal perfusion methods. Proponents of this technique claim improved results compared to those of historic control subjects in the parameters of operative mortality, postoperative renal failure, and lower extremity neurologic deficit. METHODS: Over the interval from 1987 to 1996, 160 TAA repairs (type I, 32%; type II, 15%; type III, 34%; and type IV, 19%) were performed in 157 patients with a mean age of 70 years and a male-to-female ratio of 1/1. Clinical features included ruptured TAA (10%), urgent operation (22.5%), and aortic dissection (18%). Operative management used a clamp-sew technique with regional hypothermia for spinal cord (epidural cooling, since 1993) and renal protection. Variables associated with the endpoints of operative mortality or major morbidity, particularly spinal cord injury, were assessed with Fisher exact test and logistic regression; late survival was estimated with the Kaplan-Meier method. RESULTS: In-hospital mortality was 9% and was associated with operation for rupture (p < 0.005) or other acute presentation (p < 0.001). After multivariate analysis, the postoperative complication renal failure (relative risk, 6.5 [95% confidence interval, 1.8-23.6, p = 0.004]) and significant spinal cord injury (relative risk, 16.5 [95% confidence interval, 3.2-83.2, p = 0.001]) were associated independently with operative mortality. Paraparesis-paraplegia occurred in 7%, an incidence significantly (p < 0.001) less than that (18.7%) predicted for this cohort from published models. Variables associated (univariate analysis) with this complication included TAA rupture (p < 0.0001), other acute presentation or dissection (p < 0.001), prolonged (>6 hours) operation (p < 0.04), and excessive (>3 L) transfusions (p < 0.02). Operation for acute presentation or dissection (relative risk, 7.9 [95% confidence interval, 1.7-37.7, p = 0.009]) and prolonged surgery [relative risk, 7.5 [95% confidence interval, 1.5-35.3, p = 0.01]) retained independent association with paraplegia-paraparesis after multivariate analysis. Dialysis was needed in 2.5%. Late survival at 1 and 5 years was 86 +/- 2.9% and 62 +/- 5.8%, respectively. CONCLUSIONS: These data compare favorably with those from contemporary reports using other operative strategies and do not support routine adoption of bypass-distal perfusion as the preferred technique for TAA repair.

Acute Kidney Injury↗

Continuous, non-invasive volume-clamp blood pressure: determinants of performance.

OBJECTIVE: To test a prototype hydraulic, non-invasive, continuous finger blood pressure monitor based on the volume-clamp principle for procedure-related factors likely to influence precision. DESIGN: The influence of these factors was determined by repeatability of finger blood pressure measurement and the relationship to contralateral arm-cuff blood pressure. METHODS: Repeated blood pressure measurements from three different fingers were made in 60 subjects following re-initialization of the device and re-insertion of the finger into the cuff. Repeatability was assessed in relation to simultaneous arm-cuff readings. Drift in arm-finger discrepancy was measured over a 1-h period. Finger diameter, drug therapy and presence of peripheral vascular disease were correlated with arm-finger blood pressure difference. RESULTS: Repeatability coefficients (twice the SD of the arm-finger difference) across device re-initialization were large, but similar to parallel repeated arm blood pressure determinations: 17.6 and 17.1 mmHg for systolic blood pressure (SBP) and 13.9 and 13.6 mmHg for diastolic blood pressure (DBP), respectively. Withdrawing and re-inserting the finger reduced repeatability substantially, with a 50% increase in repeatability coefficient. A trend towards a progressive 9-mmHg increase was observed in overestimation of SBP over the 1-h period. Mean +/- SD pooled arm-finger blood pressure differences were -10.8 +/- 14.6 mmHg for SBP and 4.5 +/- 9.4 mmHg for DBP. Blood pressure measured in different fingers was similar on average, with repeatability no poorer than for re-insertion of the same finger. The presence of peripheral vascular disease in 15 subjects correlated with a smaller arm-finger difference for DBP. CONCLUSIONS: Variations in positioning of the finger within the cuff influences blood pressure measurement during volume-clamp plethysmography, reducing its precision. Finger SBP exceeds brachial auscultatory readings and has similar precision.

Adult↗

Protective effects of endothelin receptor antagonists in dogs with aortic cross-clamping.

Endothelin (ET) may play an important role in the pathogenesis of vasoconstriction and acute renal failure after aortic cross-clamping (ACC). However, the relative contribution of the ET(A) and ET(B) receptors to the physiopathology of ischemic acute renal failure is poorly understood. This study was carried out to evaluate the potential protective effect of a selective ET(A) antagonist versus combined ET(A)/ET(B) antagonist on altered systemic, pulmonary, and renal hemodynamics induced by cross-clamping the suprarenal aorta for 1 h, followed by 2-h reperfusion. Studies were performed in three groups of anesthetized mongrel dogs. After baseline measurements, treatment (3 mg/kg i.v. bolus + 3 mg/kg/h infusion) with either a selective ET(A) antagonist, Ro 61-1790 (n = 5), or a combined ET(A)/ET(B) antagonist, bosentan (n = 5) or vehicle (n = 8) was initiated 5 min before ACC. There were marked increases in total peripheral (TPR), pulmonary (PVR), and renal (RVR) vascular resistances, and significant decreases in cardiac output (CO) and glomerular filtration rate (GFR) and tubular sodium reabsorption after ACC in the vehicle group. Both Ro 61-1790 and bosentan prevented the marked increases in TPR, PRV, and RVR, and attenuated the declines in CO, GFR, and tubular sodium reabsorption. We concluded that the profound systemic, pulmonary, and renal vasoconstriction, as well as the impairments in glomerular and tubular functions associated with ACC, is mostly ET mediated and that the ET(A) receptor activation makes a major contribution to the ET-mediated impairments of hemodynamics and renal function after ACC.

Acute Kidney Injury↗

Atlantoaxial arthrodesis using Halifax interlaminar clamps reinforced by halo vest immobilization: a long-term follow-up experience.

Thirty-two patients who underwent atlantoaxial arthrodesis using Halifax interlaminar clamps and halo vests between January 1989 and December 1992 were reviewed. The atlantoaxial instabilities were related to trauma in 16 patients, including 14 patients with unstable odontoid fractures, 1 patient with a complex C2 fracture, and 1 patient with a disrupted transverse ligament. Of the other 16 patients, whose atlantoaxial instabilities were nontraumatic in origin, 9 had instabilities that were secondary to rheumatoid arthritis, 1 had instability that was secondary to tuberculous infection, and 6 had instabilities that were caused by os odontoideum. The patients were followed postoperatively with lateral cervical radiographs for an average of 37 months (range, 16-59 mo). Solid atlantoaxial arthrodeses were achieved in all (100%) of these 32 patients after 32 to 111 days (average, 84.5 d) of halo immobilization, indicating atlantoaxial arthrodeses can be reasonably anticipated when Halifax interlaminar clamps with autogenous iliac bone grafting are reinforced by halo vest immobilization for 3 months.

Adolescent↗

Hepatic microcirculatory disturbances due to portal vein clamping in the orthotopic rat liver transplantation model.

Most modifications and applications of the orthotopic rat liver transplantation (ORLT) model require clamping of the portal vein, thus leading to ischemia of the gut. The purpose of this study was to evaluate the effect of portal vein clamping during ORLT on hepatic microcirculation and leukocyte--endothelial interaction by intravital fluorescence microscopy. ORLT were performed following 1 hr of cold storage in EuroCollins solution without (standard group) and with insertion of a portojugular shunt (shunt group) to minimize intestinal ischemia. ORLT induced reduction of perfused sinusoids (83%) and velocity of leukocytes (311 +/- 4.5 microns/sec; mean +/- SEM) compared with nontransplanted controls (99% and 417 +/- 4.9 microns/sec). Portojugular shunt during ORLT improved hepatic microvascular perfusion (89% and 355 +/- 3.4 microns/sec; P less than 0.05). Furthermore, percentage of permanent and temporary adherent leukocytes decreased significantly when a portosystemic shunt was applied (from 33.5 +/- 1% to 22.1 +/- 1% and 19.7 +/- 1.2% to 14.0 +/- 0.9%; P less than 0.05). The results of the study reveal that intestinal congestion and reperfusion results in a rise in leukocyte adhesion to the sinusoidal wall and in disturbances of the hepatic microcirculation. It seems likely that increased endotoxin concentrations in the portal vein induce an activation of hepatic macrophages that subsequently cause release of chemoattractant mediators. In conclusion, side effects of intestinal ischemia during experimental liver transplantation surgery on liver function due to release of chemoattractant mediators should be considered when experimental data are transferred to clinical settings.

Animals↗

Water jet assisted laparoscopic partial nephrectomy without hilar clamping in the calf model.

PURPOSE: Hemostasis represents a primary challenge during laparoscopic partial nephrectomy (LPN). We typically clamp the renal artery/vein en bloc and perform LPN expeditiously under warm ischemia conditions. We evaluated Helix Hydro-jet assisted LPN without renal hilar vascular control in the survival calf model. MATERIALS AND METHODS: Staged bilateral LPN using the Hydro-jet was performed without renal hilar vessel control in 10 survival calves (20 kidneys). Parenchymal hydrodissection was performed with a high velocity, ultracoherent saline stream at 450 psi through a small nozzle with integrated suction at the tip. The denuded intrarenal parenchymal blood vessels were precisely coagulated with a BIClamp bipolar instrument and transected. Followup involved biochemical, radiological and histopathological evaluation at designated sacrifice intervals of 1 and 2 weeks, and 1, 2 and 3 months, respectively. RESULTS: All LPNs were completed successfully without open conversion. Of 20 LPNs 18 (90%) were performed without hilar clamping. Pelvicaliceal suture repair was necessary in 5 of 10 chronic kidneys (50%). Mean Hydro-jet(R) partial nephrectomy time was 63 minutes (range 13 to 150), mean estimated blood loss was 174 cc (range 20 to 750) and mean volume of normal saline used for hydro-dissection was 260 cc (mean 50 to 1,250). No animal had a urinary leak. Histological sections from the acute specimen revealed a thin (1 mm) layer of adherent coagulum at the amputation site with minimal thermal artifact. At 2 weeks a layer of adherent fibro-inflammatory pseudomembrane with giant cell reaction was seen. CONCLUSIONS: In this more stringent and robust survival calf model Hydro-jet assisted LPN can be performed without hilar vessel control, thus, completely avoiding warm ischemia. This approach has the potential to decrease the level of technical difficulty inherent in LPN.

Animals↗

QEEG changes during carotid clamping in carotid endarterectomy: spectral edge frequency parameters and relative band power parameters.

Intraoperative monitoring is needed to identify accurately those patients in need of a shunt during carotid endarterectomy. EEG can be used for this purpose, but there is no consensus on the variables to use. Using a database consisting of 149 EEGs recorded from patients during carotid endarterectomy under isoflurane (n=61) or propofol (n=88) anesthesia and who did or did not receive a shunt, the authors investigated which of 16 derivations (common reference, Cz) and 12 parameters (relative and absolute powers and spectral edge frequencies [SEFs]) singly or in combination could best distinguish between the shunt and the nonshunt groups for the two anesthesia regimens. Receiver operating characteristic curves were used to select derivation/parameter combinations for three types of trend computation: (1) values of relative powers and SEFs during clamping (C) only, (2) clamp minus preclamp (baseline) differences (C-B), and (3) C-B differences in absolute logarithmic power (DeltalogP). For both anesthesia regimens, C-B computation distinguished best between the shunt and nonshunt groups. For isoflurane anesthesia, SEF parameters were the best, and for propofol anesthesia the relative power parameters. Discriminant analysis, in which additional derivation/parameter combinations were added, increased the discriminative power of the DeltalogP computation but not of the C or C-B computations. For isoflurane anesthesia, SEF 90% was the best single parameter for distinguishing between patients who did and did not need a shunt and the four best derivations were F3-Cz, P4-Cz, C4-Cz, and F7-Cz. For the propofol anesthesia, the relative power (C or C-B computations) of the delta band was the best and the four best derivations were F8-Cz, T4-Cz, C4-Cz, and F4-Cz.

Anesthetics, Inhalation↗

Measurement of GABA-evoked conductance changes of lobster muscle fibres by a three-microelectrode voltage clamp technique.

The effective membrane conductance and capacity of lobster muscle fibres was measured by a three-intracellular-microelectrode voltage clamp technique. Conductance values agreed well with those determined under current clamp, by means of the 'short' cable equations. Reversible increases in conductance evoked by gamma-aminobutyric acid (GABA) were reflected by differences (delta V) in electrotonic potential amplitude recorded at the centre, and midway between the centre and fibre end respectively. GABA dose--conductance curves derived from cable theory or from delta V measurements were virtually identical. The effective capacity (ceff), determined from the area beneath the 'on' delta V capacity transient, yielded values of the membrane time constant consistently lower than those obtained by the graphical method of E. Stefani & A.B. Steinbach (J. Physiol., London. 203, 383-401 (1969)); one possible explanation for this discrepancy is discussed. In the presence of GABA, the effective capacity was reduced in a dose-related manner. The results were interpreted in terms of an equivalent circuit in which surface membrane was arranged in parallel with cleft-tubular membrane of finite conductance, charged through an access resistance. GABA was though to be decreasing ceff by selectively increasing the conductance of the cleft-tubular membranes.

Animals↗

Voltage-clamp studies on the canine Purkinje strand.

Purkinje strands were excised from the left and right ventricles of adult mongrel dogs and cut to lengths of less than 2.0 mm in order to apply the two-microelectrodes voltage-clamp technique. A sizeable fraction of these preparations fully recover following dissection, with resting potentials more negative than--80 mV and upstroke velocities faster than 290 V s-1. Analysis of the voltage response to small current pulses shows that the short Purkinje strands can be treated as simple finite one-dimensional cables with ends of infinite resistance. The average length constant is 2.5 mm. In keeping with the relatively long length constant, insertion of a third microelectrode along the strand demonstrates a high degree of longitudinal homogeneity of the voltage clamp. Analysis of the capacity transient gives an estimate of the total capacity, normalized to cylindrical surface area, of 11.5 muF cm-2. The final decay of the capacity transient is a single exponential with an average time constant of 1 ms. A second slower component to the final decay of the capacity transient is absent in solutions of normal conductivity as well as in solutions of reduced (13%) conductivity. This suggests that the extracellular series resistance may be relatively small. The magnitude of the K+ depletion current was estimated by measuring the ratio of depletion current to instantaneous current. This ratio averaged 10%. These two results are consistent with the morphometric data described in the accompanying paper, which show that the canine preparation has wider extracellular clefts than the ungulate preparation. The existence of the full complement of inward and outward currents, including the pacemaker current, is demonstrated. The presence of wide clefts does not affect the potential at which the pacemaker current reverses (about--107 mV in 4 mM [K+] Tyrode solution), since the pacemaker current reverses at approximately the same potential in the canine Purkinje preparation as it does in the ungulate.

Action Potentials↗

Genetic and voltage-clamp analysis of a Drosophila potassium channel.

These genetic and voltage-clamp studies have produced evidence that strongly supports the hypothesis that the Shaker locus codes for at least one molecular component of the IA channel. Mutations at the Shaker locus have effects that are specific to IA, and thus a general membrane component is not produced by this locus. Regarding the function of the Shaker product itself, there is evidence that it is at least involved in the inactivation and recovery process of the channel. The evidence so far is also consistent with there being a single Shaker product per channel. Regarding its genetic and developmental properties, IA is apparently completely independent of the other major voltage-activated K+ channel in the membrane, IK. However, only after molecular information becomes available will it become clear whether or not these experiments have revealed clues about the molecular nature of these channels. Ultimately, voltage-clamp experiments, even combined with resourceful genetic tools, can only reveal circumstantial information about the molecular structure of channels. It is hoped, however, that these studies have stimulated interest in the Shaker locus and that the way has been well prepared for molecular studies of the IA channel. The actual molecular characterization of the Shaker locus is already under way (cf. Jan et al., this volume; M. Tanouye , pers. comm .).

Animals↗

Pressure clamp method to measure transpiration in growing single plant cells : demonstration with sporangiophores of phycomyces.

A pressure probe method (pressure clamp) was developed to measure transpiration rates of both growing and nongrowing single plant cells, and represents an improvement over the previous pressure probe method (pressure relaxation), which is restricted to nongrowing plant cells (J.K.E. Ortega, R.G. Keanini, K.J. Manica [1988] Plant Physiol 87: 11-14). The pressure clamp method was used to measure transpiration rates of Phycomyces sporangiophores in two developmental stages: stage III (nongrowing) and stage IV (growing).

Journal Article↗

Enlargement in chara studied with a turgor clamp : growth rate is not determined by turgor.

A new method, the turgor clamp, was developed to test the effects of turgor on cell enlargement. The method used a pressure probe to remove or inject cell solution and change the turgor without altering the external environment of the cell walls. After the injections, the cells were permanently at the new turgor and required no further manipulation. Internode cells of Chara corallina grew rapidly with the pressure probe in place when growth was monitored with a position transducer. Growth-induced water potentials were negligible and turgor effects could be studied simply. As turgor was decreased, there was a threshold below which no growth occurred, and only reversible elastic/viscoelastic changes could be seen. Above the threshold, growth was superimposed on the elastic/viscoelastic effects. The rate of growth did not depend on turgor. Instead, the rate was highly dependent on energy metabolism as shown by inhibitors that rapidly abolished growth without changing the turgor. However, turgors could be driven above the maximum normally attainable by the cell, and these caused growth to respond as though plastic deformation of the walls was beginning, but the deformation caused wounding. Growth was inhibited when turgor was changed with osmotica but not inhibited when similar changes were made with the turgor clamp. It was concluded that osmotica caused side effects that could be mistaken for turgor effects. The presence of a turgor threshold indicates that turgor was required for growth. However, because turgor did not control the rate, it appears incorrect to consider the rate to be determined by a turgor-dependent plastic deformation of wall polymers. Instead, above the turgor threshold, the rapid response to energy inhibitors suggests a control by metabolic reactions causing synthesis and/or extension of wall polymers.

Journal Article↗