Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ACRYLIC RESINS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94Linked to original sources

Impact properties of acrylic denture base resin. 2. Effect of temperature and residual monomer on impact characteristics.

The temperature dependence of the impact strength, resilience, and toughness of the acrylic denture base resins on temperature changes was examined by using a modified impact testing machine. In addition, the creep properties and the residual monomer of their resins were measured; and considering these properties, the impact characteristics of the denture base resins were discussed. With an increase in temperature, the impact properties of all the acrylic denture base resins tested decreased. Furthermore, there was an adequate correlation between the impact characteristics and the amount of the residual monomer. The coefficient of correlation was 0.92 for the impact strength, -0.95 for the resilience and 0.94 for the toughness. For the cold cured acrylic resins, both elastic moduli obtained by the impact test and by the creep test increased obviously according to an increase in the time which elapsed after polymerization.

Acrylic Resins↗

Posterior composite resins.

A quarter of a century ago, composite resin was introduced and quickly outmoded silicate cement and acrylic resin as a restorative material. Although composite resin cannot replace amalgam, it has a strong foothold in dentistry, most notably for its superior color-matching ability. This article contrasts many properties of composite resin to amalgam, and takes a look at new developments in posterior esthetic materials.

Chemical Phenomena↗

Effect of bonded restorations on the fracture resistance of root filled teeth.

AIM: To evaluate the fracture resistance of root filled maxillary premolars restored with different techniques. METHODOLOGY: One hundred and twenty single-rooted maxillary premolar teeth were divided randomly into six groups of 20 teeth and subjected to the following procedures: group 1: intact teeth. Group 2: endodontic access cavities prepared. Group 3: MOD cavities were prepared, root canals were filled and no restoration was placed. Group 4: teeth were prepared as group 3 and restored conventionally with amalgam. Group 5: teeth were prepared as group 3 and restored with amalgam using a bonding material. Group 6: teeth were prepared as group 3 and restored with composite resin using the same bonding material. Teeth were embedded in acrylic resin and the loads for fracture strength were applied vertically with a constant speed of 1 mm min(-1). Data were evaluated statistically with anova and Tukey's tests. RESULTS: The mean force of fracture values were 1191.41, 599.86, 233.03, 494.72, 962.81 and 856.48 N for groups 1, 2, 3, 4, 5 and 6, respectively. The fracture resistance of group 5 was similar to group 1 (P > 0.05). The mean force at fracture of group 5 and group 6 was not significantly different. The fracture resistance of groups 5 and 6 was significantly higher than group 4 (P < 0.001). CONCLUSIONS: The group, restored with conventional amalgam, had the weakest resistance to fracture when compared with the bonded restorations. No statistically significant differences were found between the bonded amalgam and composite resin groups.

Acid Etching, Dental↗

An in vitro investigation of water sorption and solubility of two acetal denture base materials.

Acetal resins have been used as an alternative denture base and clasp material recently. The aim of this study was to compare water sorption and water solubility of pink and white acetal resins as compared to a heat-polymerized polymethyl methacrylate resin (PMMA). The tests were performed in accordance with International Standards Organization specification No: 1567. Pink acetal resin showed significantly lower water sorption than heat-polymerized acrylic resin and white acetal resin. PMMA showed significantly higher solubility than pink and white acetal resin. Water sorption and solubility of PMMA, pink and white acetal resins were within the ISO specification limit.

Polymethyl Methacrylate↗

Methods for physical stabilization of ashed teeth in incinerated remains.

Methods for physically stabilizing the extremely fragile ashed teeth that are often encountered in incinerated human remains were investigated. Results of a questionnaire sent to forensic anthropologists and forensic odontologists disclosed that, for these two groups, the most popular methods currently used are impregnation with a solution of polyvinyl acetate or application of cyanoacrylate cement, respectively. In addition, extracted human teeth were incinerated in the laboratory and impregnated with commercially available preparations of either cyanoacrylate cement, clear acrylic spray paint, hair spray, spray furniture varnish, clear fingernail polish, quick-setting epoxy cement, Duco household cement, polyvinyl acetate polymer in acetone, or self-curing clear dental acrylic resin. Every substance tested successfully stabilized the incinerated teeth. Clear acrylic spray paint was judged the most efficacious overall because of its ease of application, availability, inexpensiveness, and rapidity of setting.

Burns↗

Principles of enamel etching.

Amongst the innovations that have changed the practice of dentistry over the past three decades, the acid-etch technique and the use of composite resins may be regarded as two of the most influential. In 1955, Michael Buonocore, a researcher at the Eastmen Dental Centre in Rochester, New York, made the astute observation that the application of weak inorganic acid could alter the surface enamel so that bonding of a resin to the surface could take place. Buonocore experimented with acrylic resins but found these were much too weak to withstand the stresses exerted upon them in the mouth. It was not until Rafael Bowen developed a unique system containing 25 percent by weight of polymerisable monomer and 75 percent by weight of a vitreous filler--the composite resin--that the acid-etch technique became an effect procedure. This article reviews historical and current research, in the search to optimise the resin to enamel bond.

Acid Etching, Dental↗

Cytotoxicity evaluation of a new radiopaque resin additive--triphenyl bismuth.

Triphenyl bismuth (Ph3Bi) is a promising new additive for making biomedical resins visible on x-ray images. We evaluated the cytotoxicity of Ph3Bi, both alone and as a component of a denture resin, as an initial step in determining its biocompatibility. These experimental materials were compared with several types of dental materials that are in current clinical use (PMMA denture acrylic resin, two photo-cured sealants, and two glass-ionomer cements). Human embryonic lung fibroblast tissue cultures (WI-38 cells) were exposed to 24-hour aqueous extracts of the materials. Changes in cell growth, cell viability, and the visual appearance of cells were used for the assessment of toxic response. Only a slight degree of cytotoxicity was observed for Ph3Bi, both alone and in combination with self-cured PMMA. All clinical materials showed a higher level of cytotoxicity than did Ph3Bi. The sealants and cements exhibited the most cytotoxicity and PMMA acrylic the least. The cytotoxicity of PMMA was elevated slightly by inclusion of Ph3Bi, probably due to decreased monomer conversion. When stored in water, the already low levels of cytotoxicity of both PMMA and PMMA with added Ph3Bi were reduced even further. From these results, we can predict a high level of safety for Ph3Bi as a radiopaque additive for biomedical resins. Any toxicity associated with Ph3Bi-containing resins can be reduced or avoided by prior extraction. Alternatively, curing conditions can be selected that would drive the polymerization reaction to a higher level of conversion.

Acrylic Resins↗

Contact dermatitis to anaerobic sealants.

High-performance polymerizable anaerobic sealants originated in 1953 and are used to lock metal parts together chemically. A case of hand contact dermatitis from Loctite RC/601, 242, and 504 is reported in a 60-year-old machine assembler. This diagnosis was documented by positive patch tests of the product and of three of the components: polyethylene glycol dimethacrylate, hydroxypropyl, and hydroxyethyl methacrylate. This is the third report of contact dermatitis caused by these sealants in the United States, is the second in the world on hydroxypropyl methacrylate, and is another example of the wide environmental use of potentially sensitizing acrylic resins.

Acrylates↗

Impregnation of soft biological specimens with thermosetting resins and elastomers.

A new method for impregnation of biological specimens with thermosetting resins and elastomers is described. The method has the advantage that the original relief of the surface is retained. The impregnation is carried out by utilizing the difference between the high vapor tension of the intermedium (e.g., methylene chloride) and the low vapor tension of the solution to be polymerized. After impregnation, the specimen is subject to polymerization conditions without surrounding embedding material. The optical and mechanical properties can be selected by proper choice from various kinds of resins and different procedures, for example, by complete or incomplete impregnation. Acrylic resins, polyester resins, epoxy resins, polyurethanes and silicone rubber have been found suitable for the method. Excellent results have been obtained using transparent silicone rubber since after treatment the specimens are still flexible and resilient, and have retained their natural appearance.

Animals↗

Effect of two dentinal desensitizing agents on retention of complete cast coping using four cements.

The cementation of artificial crowns is commonly accompanied by sensitivity, so the clinical application of desensitizing agents has become prevalent. This study investigated the effects of Imperva bonding agent and All-Bond desensitizing agent on the retention of artificial crowns. The cements selected for this study were: zinc phosphate, polycarboxylate, glass ionomer, and resin luting agents. Extracted, intact, human molars were mounted in autopolymerizing acrylic resin and prepared for complete cast copings. Thirty-two teeth were treated with All-Bond desensitizing agent, 32 teeth with Imperva bonding agent, and 32 remained untreated. Castings were cemented and tested on an Instron testing machine. The results demonstrated a significant reduction in retention when All-Bond desensitizing agent was used with polycarboxylate cement and some reduction with zinc phosphate cement. Imperva bonding agent demonstrated less retention with glass ionomer cement.

Analysis of Variance↗

Thermoplastic resin used to modify an alveolar orthopedic prosthesis in a patient with cleft lip before cheiloplasty: a clinical report.

Correction of cleft lip and cleft palate is a multidisciplinary team effort. Severe bilateral clefts with protruded and rotated premaxillae may complicate surgical correction. Prosthetic intervention to reposition segments before surgical correction may improve the bony base for tissue molding and avoid excess tension at the surgical site. A conventional bulb prosthesis with bonnet and straps is often used as an extraoral device to retract a protruded premaxilla for severe cleft patients before cheiloplasty. Sometimes, because of lack of retention, stability, patient compliance, and controllable forces from a bonnet and straps, movement of the premaxillae to a desirable position is difficult to achieve. The use of thermoplastic resin to modify a bulb prosthesis as described in this clinical report is a simple method to provide good retention for the bulb prosthesis and to move a laterally displaced premaxillae to the facial midline. The wedging effect created by the thermoplastic resin generated "compressive forces" to the premaxilla that was more controllable than the pulling forces created by the bonnet and straps therapy. Thermoplastic resin is also a better material than a conventional chemically polymerized acrylic resin in dealing with an infant's delicate mucosa before cheiloplasty.

Cleft Lip↗

Removal of THM precursors by coagulation or ion exchange.

The removal of natural organic matter (NOM) from drinking water supplies can be achieved by different processes, among them coagulation and adsorption. Synthetic waters made from concentrates of humic substances from reservoir and river waters were tested in the laboratory for ease of removAl of NOM by coagulation with cationic organic polymers and with alum, and by adsorption on anion exchangers. For polymers such as high molecular weight polydiallyldimethylammonium chloride (polyDADMAC) and cationic polyacrylamides of high charge, performance was nearly as effective as alum, with colour removals 86-100% of those obtained for alum. Ion exchange using the best commercially available resins designed for this purpose, a gel polystyrene and a macroporous acrylic resin, was more effective than alum treatment for two of the natural waters studied, but inferior for a third. The resins were overall superior to cationic polymers. The NOM was separated into four fractions based on hydrophobic and hydrophilic properties. Alum was not as effective as ion exchange for the elimination of individual ionic NOM fractions. It was better than cationic polymers for removal of humic and fulvic acids, although polyDADMAC was as good for one water. For the removal of charged compounds alum then polyDADMAC were the best performers for that water. Unequivocal evidence was obtained that coagulants remove material that is not adsorbed by resins, and vice versa. A combination of coagulation with a cationic polymer and adsorption by an anion exchanger removed essentially all of the NOM. The preference of the coagulants was for the larger, more hydrophobic molecules, and of resins for smaller highly charged hydrophilic molecules. Each fraction had trihalomethane formation potentials in the range 11-24 microg/mg, except for one water that was more reactive. Hence, the actual amount of each fraction in the original water becomes a crucial factor.

Alum Compounds↗

Simultaneous activation technique: an alternative for bonding composite resin to glass ionomer.

PURPOSE: The purpose of this study was to evaluate a new simultaneous activation technique (SAT)-for the union between glass ionomer cements and composite resins. METHODS: Forty primary molars were embedded in self-curing acrylic resin. Class I cavity preparations were performed on the dentin surface and the teeth were randomly divided into 4 groups (N = 10). Two groups were restored with the SAT and 2 by etching the ionomer surface/sandwich technique (ST). The materials tested were Vidrion F (SS/ White), Vitremer (3M), and Z100 (3M). After 24 hours in aqueous solution at 37 degrees C, a tensile test was performed. The microleakage study was also performed by selecting 40 primary molars which were distributed in the same way as in the bond strength test. Furthermore, 1 tooth from each group of the microleakage test was evaluated by means of scanning electron microscopy. RESULTS: The SAT and ST did not show statistically significant differences in both tests. CONCLUSIONS: The SAT is a less complex, quicker, and feasible alternative for the bonding of glass ionomer cements to composite resins in primary molars.

Acid Etching, Dental↗

Impact properties of acrylic denture base resin. 3. Impact properties of cross-linked polymers.

The impact properties in acrylic denture base resins cross-linked using 6 diacrylates, such as ethylene glycol dimethacrylate (EDMA) and rho-divinyl benzene (DVB), were investigated and discussed. In addition, the creep characteristics of these cross-linked resins were examined and related with their impact characteristics. From these results, it was seen that both characteristics deteriorated with an increase in the diacrylate concentration from 2 mol% to 10 mol%. On the other hand, an increase in the repeated number (n) of (--CH2--CH2--O--)n promoted a flexibility in the materials which resulted in a higher impact strength and toughness. But, there was no a significant difference in the resilience of these materials.

Acrylic Resins↗