Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “VESSELS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93Linked to original sources

Muscarinic binding of pial vessels and arachnoid membrane.

The muscarinic sites in arachnoid and pial vessels were compared by analysis of the binding of quinuclidinyl benzilate (QNB) to membrane preparations. Saturation analysis indicated that the process was saturable, high affinity, and related to protein concentration in both structures. Although the affinities in the two structures [KD = 0.039 (arachnoid) and 0.097 nM (pial vessels)] were similar, the arachnoid had approximately 10-fold more binding sites (Bmax = 2,100 fmol/mg of protein) than the pial vessels (Bmax = 250 fmol/mg of protein). This difference was found in both bovine and porcine fractions. Pharmacological analysis of [3H]QNB displacement by muscarinic and nonmuscarinic ligands gave the typical pattern of muscarinic receptors in both structures. Inhibition of binding to pial vessels by the M1 antagonist pirenzepine revealed only one low-affinity site (Ki = 7.8 x 10(-7) M), whereas, the arachnoid had a small proportion (21%) of high-affinity sites (Ki = 2.2 x 10(-9) M) associated with low-affinity sites (Ki = 5.50 x 10(-7) M). It is concluded that muscarinic-mediated effects that do not involve the M1 subtype are induced in bovine pial vessels by a relatively low concentration of binding sites. The high content of muscarinic binding sites and their diversity in the arachnoid suggest a functional role for muscarinic cholinergic receptors in this structure.

Animals↗

Response to acetylcholine and nicotine of the perfused vessels of the rabbit ear.

1. The vessels of the isolated rabbit ear were perfused at 23 mbar with Krebs solution with (tonic) and without (atonic) noradrenaline (5.9 x 10(-7)M) at selected temperatures of 20 degrees -38 degrees C. Peripheral resistance units (PRU) were calculated from the observed peak flow rates and alterations caused by drugs expressed as Delta% PRU.2. ACh is constrictor in the atonic vessel.3. ACh is a vasodilator of the tonic vessel perfused with NA. This effect is potentiated by anticholinesterase and by denervation, unaffected by botulinum toxin and antagonized by atropine. ACh also dilates the vessel perfused with vasopressin.4. Increasing the temperature reduces the responses to ACh but increases the effect of anticholinesterase.5. Nicotine causes a dose dependent dilatation of the tonic vessels, reduced but not abolished by C(6), by atropine, by botulinum toxin and by denervation.6. Nicotine causes a dose dependent constriction of the atonic vessels, abolished by C(6) and by phentolamine, reduced by denervation, but unaffected by botulinum toxin.

Acetylcholine↗

Anaphylactic contraction of pulmonary blood vessels of chicken.

1 Isolated pulmonary arterial and vein strips from sensitized or non-sensitized chickens exhibited dose-dependent contractions to adrenaline greater than, noradrenaline greater than, 5-hydroxytryptamine greater than, histamine greater than, dopamine. Individual variability in the responsiveness of the vessels to agonists was marked. In general veins were 2 to 25 times more sensitive to agonists than arterial strips. 2 Isoprenaline (a relatively specific beta-adrenoceptor agonist) induced relaxation of the submaximally contracted pulmonary vein and arteries at low doses and contractions at high concentrations. 3 Contractile responses to acetylcholine or carbachol were not regularly recorded; only 50% of the vessels reacted to cholinoceptor agonists over a wide threshold dose range. 4 Chicken pulmonary vessels were found relatively insensitive to bradykinin. 5 Effects of prostaglandins were variable. Prostaglandin F2alpha induced dose-related contractions of the vein and arterial strips; prostglandins E1 and E2 at low doses partially contracted pulmonary artery irrespective of the spasmogen used and further increase in doses induced either no effect or contractions. Prostaglandin E1 induced marked and rapid contractions of the vein. Prostaglandin E2 induced relaxations of the prostaglandin F2alpha-contracted vein only, but produced no effect or slight contractions of the veins partially contracted to other spasmogens. 6 Pulmonary arterial and vein strips obtained from chickens sensitized to horse plasma exhibited Schultz-Dale contractions of variable magnitude and duration to specific antigenic challenge only. In many vessels, antigen-induced contractions were associated with marked increase in spontaneous activity. 7 The importance of the Schultz-Dale reaction in avian pulmonary vessels is discussed in relation to the right heart dilatation associated with anaphylaxis in the chicken.

Acetylcholine↗

The influence of endothelin-1 on human foeto-placental blood vessels: a comparison with 5-hydroxytryptamine.

1. The vasoconstrictor effect of endothelin-1 (3 x 10(-11) M-10(-7) M) was studied in successive generations of blood vessels of the foeto-placental vascular tree. These were the human umbilical arteries and veins, primary surface chorionic plate arteries, secondary chorionic plate arteries, tertiary surface chorionic plate arteries and veins and the secondary stem villus arterioles. The responses to endothelin-1 were compared with those to 5-hydroxytryptamine (10(-9) M-10(-5) M). Arterial preparations were gassed with 2.5% O2, 8% CO2 balance N2 and venous preparations were gassed with 5% O2, 6% CO2 balance N2 to simulate the conditions prevalent in utero. The influence of increasing the oxygen tension to 16% (that prevalent at birth) on the response to endothelin-1 on the umbilical arteries was also investigated. 2. All the arterial vessels tested were some ten times more sensitive to endothelin-1 than to 5-hydroxytryptamine and the venous preparations were ten times more sensitive to endothelin-1 than were their equivalent arteries. Increasing oxygen tension did not affect the responses to endothelin-1 in the umbilical artery. 3. Whilst the amplitude of the endothelin-1-induced response was uniform throughout the foetoplacental vascular tree, including the stem villus arterioles, the maximum response to 5-hydroxytryptamine decrease with successive generations and it had no significant effect on the stem villus arterioles.The ratios of the responses to 10- M endothelin-1: 10-7M 5-hydroxytryptamine in human umbilical arteries, primary surface chorionic plate arteries, secondary chorionic plate arteries,tertiary surface chorionic plate arteries and the secondary stem villus arterioles in the vessels (listed in order of decreasing vessel size) were 1:1.2, 1:0.36, 1:0.33, 1:0.35 and 1:0.04 respectively.4. In conclusion, endothelin-1 is a powerful vasoconstrictor at all levels of the foeto-placental vascular system including the stem villus resistance vessels. It may play an important role in maintaining foeto-plancental vascular resistance at the low oxygen tension which exists in this vascular system in utero.

Blood Vessels↗

ETA receptor-mediated constrictor responses to endothelin peptides in human blood vessels in vitro.

1. We have characterized the constrictor endothelin receptors present in human isolated blood vessels using ETA and ETB selective agonists and antagonists. 2. Monophasic dose-response curves were obtained for ET-1 with EC50 values of 6.8 nM in coronary artery, 3.9 nM in internal mammary artery, 17.4 nM in pulmonary artery, 14.5 nM in aorta and 3.2 nM in saphenous vein. In coronary artery, ET-2 was equipotent with ET-1 with an EC50 value of 5.7 nM. The non-selective peptide, sarafotoxin 6b, was 2-3 times less potent than ET-1 but the maximum responses to these two were comparable. 3. In each vessel ET-3 was much less active than ET-1. No response was obtained to ET-3 in aorta and pulmonary artery or in up to 50% of coronary artery, mammary artery and saphenous vein preparations. In those preparations that did respond, dose-response curves were incomplete at 300 nM. Variable contractions were also obtained with the ETB-selective agonist, sarafotoxin 6c (S6c). Where responses were detected, although S6c was more potent than ET-1 (EC50 values of 0.6-1.2 nM), the maximum response produced was always less than 20% of that to ET-1. 4. The synthetic ETB agonists, BQ3020 and [1,3,11,15Ala]-ET-1, were without effect in any of the five blood vessels at concentrations up to 3 microM. 5. ET-1-induced vasoconstriction was blocked by the ETA-selective antagonists, BQ123 and FR139317. Schild-derived pA2 values were 7.0, 7.4 and 6.9 for BQ123 and 7.6, 7.9 and 7.3 for FR139317 in coronary artery, mammary artery and saphenous vein, respectively, consistent with antagonism of ETA receptors. Slopes of the Schild regressions were not significantly different from one. Comparable values of pA2 were estimated for 3ftM BQ123 in aorta (7.4+/-0.5) and pulmonary artery (6.9) from the Gaddum-Schild equation.6. In conclusion we have shown that in human isolated blood vessels, ET-1 is more potent than ET-3 suggesting the presence of vasoconstrictor ETA receptors. This is supported by the lack of effect of the ETB agonists, BQ3020 and [1,3,1,1,15Ala]-ET-l and the ability of the ETA antagonists, BQ123 andFR139317 to block ET-1 responses. Some preparations did contract in response to low concentrations of the ETB-selective sarafotoxin 6c but responses were variable and the maximum was always much less than that to ET-1 in the same preparations. Therefore although constrictor ETB receptors were present on the smooth muscle of human blood vessels, vasoconstriction elicited by the endothelin peptides in vitro is via ETA receptor activation.

Adolescent↗

A comparative stereologic and ultrastructural study of blood vessels in odontogenic keratocysts and dentigerous cysts.

Blood vessels were investigated both stereologically and ultrastructurally in keratocyst and dentigerous cyst. The volume and surface densities of blood vessels in 15 keratocysts and dentigerous cysts were analyzed stereologically. No significant differences were found between them using these parameters, suggesting that their overall vascularity may be similar. However, the ultrastructural study showed marked differences between blood vessels in these two types of cysts. It was observed that fenestrated capillaries were found only in keratocysts. In addition, degeneration of endothelial lining associated with thrombosis was also a prominent feature of this cyst. While ruptured endothelium, narrow lumen and Weibel-Palade bodies were characteristic of vessels in dentigerous cyst. The presence of fenestrated capillaries in keratocyst and not in dentigerous cyst might indicate a rapid transfer of fluid to meet the demand of the relatively active proliferating epithelium, which may be promoted by growth factors released from platelets in those thrombosed vessels.

Arterioles↗

Transphyseal vessel involvement in repair of metaphyseal retained cartilage.

A foal with retained cartilage in the distal metaphysis of the right and left radii and third metacarpal bones had abnormal physeal vasculature. In areas where cartilage was retained, vessels crossed the physis, and branched at the physeal-metaphyseal junction or at the site of retained cartilage. Vessels appeared to be involved in re-initiation of endochondral ossification and in the repair reponse to the presence of retained cartilage. In areas where the physis was radiographically and histologically normal, no vessels crossed the physis. A function of transphyseal vessels may be as a reserve blood supply in areas of metaphyseal abnormality, at a stage of maturity when metaphyseal vessels are not well developed.

Animals↗

Variations in small and large vessel volumes caused by cations, adrenaline and histamine.

1. Plasma and blood cell volumes were measured simultaneously with [(131)I]albumin and [(32)P]erythrocytes, together with the arterial haematocrits, in acutely splenectomized dogs anaesthetized with sodium barbital. These measurements were made during control runs and after the administration of vasoactive substances.2. With these data and previously derived equations the mean composite radius of all small vessels with a radius < 150 mu, the distribution of the blood volumes between small and large vessels, and other variables could be calculated.3. Adrenaline, CaCl(2) or vasopressin administration caused a reduction of the mean composite radius, a net shift of erythrocytes and plasma out of the small vessel volume, and an expansion of the large vessel volume. Histamine, KCl and MgCl(2) produced opposite effects.4. Adrenaline appeared to cause the release of sequestered erythrocytes into the active circulation.5. The effects of CaCl(2) and KCl persisted for several hours, while those of MgCl(2) did not.6. The effects of vasopressin could be reversed by histamine, those of adrenaline by splenic plasma or KCl, and those of CaCl(2) by MgCl(2).7. It was suggested that the observed vasoactions are essentially the resultants of diverse combinations of direct and indirect actions on the capacitance section of the small vessel volume.

Animals↗

Pulsed photothermal radiometry as a method for investigating blood vessel-like structures.

Pulsed photothermal radiometry (PPTR) is known to be suitable for in vivo investigations of tissue optical properties. As a noncontact, nondestructive method it is a very attractive candidate for on-line dosimetry of laser treatments that rely on thermal laser-tissue interaction. In this article, we extend the one-dimensional (1D) analytical formalism that has widely been used to describe PPTR signals to a two-dimensional treatment of a simplified model of a blood vessel. This approach leads to quantitative description of a PPTR signal that, unlike in an 1D treatment, not only shows changes in time, but also varies in space. Using this approach, we are able to gain instructive understanding on how target characteristics of a blood vessel-like structure influence such a spatiotemporal PPTR signal. Likewise, the ability of extracting target features from those measurements is evaluated. Subsequently, we present experimental realization of the idealized model of a blood vessel as used in our theory. Comparison of actual PPTR measurements with theoretical predictions allow vessel localization laterally and in depth. Using our setup, we furthermore demonstrate the influence of flow inside the vessel on the measured signal.

Blood Vessels↗

A real vessel phantom for imaging experimentation.

Vascular phantoms are used to evaluate imaging techniques such as ultrasound (US), CT, and angiography. They are expected to mimic the vasculature, surrounding tissue, and blood, and therefore must meet specific requirements on the mimicking materials, with respect to x-ray attenuation and acoustic properties (velocity, attenuation). In the past, researchers have used a variety of vessel models, including walled (typically latex tube) and wall-less phantoms (obtained by moulding a lumen in a block of agar). These models lacked the exact geometry of human vessels as well as pathologic features such as plaques and calcifications. To overcome these disadvantages, this paper describes a real vessel phantom for US and x-ray studies. The phantom consists of an agar-filled acrylic box containing a formaldehyde fixed section of a real human vessel (obtained at autopsy) cannulated onto two acrylic tubes. This phantom was evaluated by comparing the images obtained with x-ray angiography, CT, and 3-D B-mode US. The images show good overall correlation based on the location of the geometrical features within the phantom, such as lumen, plaques, and calcifications. Discrepancies, artifacts, and difficulties were minor, and are discussed. The use of a real vessel, with its natural geometry and pathology, makes this phantom attractive for evaluation of imaging techniques including projection radiography, CT and US, and for extending its use to MR and US based flow studies.

Angiography↗

A blood vessel exposed to ultrasound: a mathematical simulation of the temperature field.

In this article we present a mathematical simulation of the temperature field in and around a blood vessel when it is sonicated by a focused ultrasound beam. A simplified geometry is considered: a cylindrical blood vessel is embedded in tissue parallel to a flat skin surface. The ultrasound transducer is placed on the skin above the blood vessel, perpendicular to the skin surface. The 3D geometry of the problem is simplified by transformation, which maps the domain into a parallelepiped. A computational algorithm and computer program were developed. The simulation provides the conditions for successful occlusion of a blood vessel and demonstrates the significant role of the blood flow rate on the temperature difference between the vessel wall and the surrounding tissue. Comparing the predictions with published experimental data tested the validity of the method.

Blood Flow Velocity↗

Differential distribution of beta-adrenergic receptor subtypes in blood vessels of knockout mice lacking beta(1)- or beta(2)-adrenergic receptors.

beta-Adrenergic receptors (beta-AR) are essential regulators of cardiovascular homeostasis. In addition to their prominent function in the heart, beta-AR are located on vascular smooth muscle cells, where they mediate vasodilating effects of endogenous catecholamines. In this study, we have investigated in an isometric myograph different types of blood vessels from mice lacking beta(1)- and/or beta(2)-adrenergic receptor subtypes (beta(1)-KO, beta(2)-KO, beta(1)beta(2)-KO). In wild-type mice, isoproterenol induced relaxation of segments from thoracic aorta, carotid, femoral and pulmonary arteries, and portal vein. The relaxant effect of beta-receptor stimulation was absent in femoral and pulmonary arteries from beta(1)-KO mice. In aortic and carotid arteries and in portal veins, the vasodilating effect of isoproterenol was reduced in mice lacking beta(1)- or beta(2)-receptors. However, in these vessels the vasodilating effect was only abolished in double KO mice lacking both beta(1)- and beta(2)-receptors. Vessel relaxation induced by forskolin did not differ between wild-type and KO mice. Similar contributions of beta(1)- and beta(2)-receptors to isoproterenol-induced vasorelaxation were found when vessels from KO mice were compared with wild-type arteries in the presence of subtype-selective beta-receptor antagonists. These studies demonstrate that beta(1)-adrenergic receptors play a dominant role in the murine vascular system to mediate vasodilation. Surprisingly, beta(2)-receptors contribute to adrenergic vasodilation only in a few major blood vessels, suggesting that differential distribution of beta-adrenergic receptor subtypes may play an important role in redirection of tissue perfusion.

Animals↗

Reduced response of retinal vessel diameters to flicker stimulation in patients with diabetes.

BACKGROUND/AIM: Stimulation of the retina with flickering light increases retinal arterial and venous diameters in animals and humans, indicating a tight coupling between neural activity and blood flow. The aim of the present study was to investigate whether this response is altered in patients with insulin dependent diabetes mellitus. METHODS: 26 patients with diabetes mellitus with no or mild non-proliferative retinopathy and 26 age and sex matched healthy volunteers were included in the study. Retinal vessel diameters were measured continuously with the Zeiss retinal vessel analyser. During these measurements three episodes of square wave flicker stimulation periods (16, 32, and 64 seconds; 8 Hz) were applied through the illumination pathway of the vessel analyser. RESULTS: In retinal arteries, the response to stimulation with diffuse luminance flicker was significantly diminished in diabetic patients compared to healthy volunteers (ANOVA, p<0.0031). In non-diabetic controls flicker stimulation increased retinal arterial diameters by +1.6% (1.8%) (mean, p<0.001 v baseline), +2.8% (SD 2.2%) (p<0.001) and +2.8% (1.6%) (p<0.001) during 16, 32, and 64 seconds of flicker stimulation, respectively. In diabetic patients flicker had no effect on arterial vessel diameters: +0.1% (3.1%) (16 seconds, p = 0.9), +1.1% (2.7%) (32 seconds, p = 0.07), +1.0% (2.8%) (64 seconds, p = 0.1). In retinal veins, the response to flicker light was not significantly different in both groups. Retinal venous vessel diameters increased by +0.7% (1.6%) (16 seconds, p<0.05), +1.9% (2.3%) (32 seconds, p<0.001) and 1.7% (1.8%) (64 seconds, p<0.001) in controls during flicker stimulation. Again, no increase was observed in the patients group: +0.6% (2.4%), +0.5% (1.5%), and +1.2% (3.1%) (16, 32, and 64 seconds, respectively). CONCLUSION: Flicker responses of retinal arteries and veins are abnormally reduced in patients with IDDM with no or mild non-proliferative retinopathy. Whether this diminished response can be attributed to altered retinal vascular reactivity or to decreased neural activity has yet to be clarified.

Analysis of Variance↗

Ultrastructural distribution of collagen types I-VI in aging human retinal vessels.

Retinal vessels from freshly enucleated human eyes were classified into three stages of the hyalinisation process. The distribution of collagen types I-VI within the vessel walls was studied ultrastructurally by immunogold labelling combined with the tissue preparation techniques of cryoultramicrotomy and London resin white embedding. Collagen types I, III, IV, V, and VI were found in large vessels, types I, IV, and V plus small amounts of III and VI in small vessels, and types I, IV, and V in capillaries. Hyalinised vessel walls consisted mainly of types I, IV, and VI collagen.

Adult↗

Clinical evaluation of scanning laser polarimetry: I. Intraoperator reproducibility and design of a blood vessel removal algorithm.

AIMS: To evaluate the reproducibility of the retardation values (change in polarisation) obtained with the scanning-laser polarimeter in a series of normal subjects and glaucoma patients. To improve the analysis of the raw data by devising and evaluating a blood vessel removal algorithm. METHODS: Scanning laser polarimetry was performed on 10 normal subjects and 10 glaucoma patients. A series of six images was obtained from each eye. The normal subjects were re-imaged 3 months after their initial assessment. The retardation values obtained from each eye were analysed using the authors' own methods, including the use of an algorithm to remove blood vessels from the polar profiles. The reproducibility of these measurements and the performance of the blood vessel removal algorithm were assessed. RESULTS: The "individual point" coefficient of variation was approximately 12.5% for normal subjects and 17.0% for glaucoma patients. The "integral" coefficient of variation for these groups was approximately 5.5% and 9.5% respectively. The reproducibility of the measurements did not improve with an increased number of measurements. There was no difference in the reproducibility of the measurements in normal subjects over time. The blood vessel removal algorithm improved the reproducibility of the measurements when the shape of the profile was assessed. CONCLUSION: The intraoperator reproducibility of retardation values obtained with the scanning laser polarimeter is satisfactory for its use as a clinical tool. The use of a blood vessel removal algorithm improves the reproducibility of the measurements and also assists the clinician in the interpretation of the polar profiles. Furthermore, it allows the construction of normal database polar profiles, thereby enabling the identification, location and quantification of retinal nerve fibre layer damage in an "at risk" individual's polar profile.

Algorithms↗

Ventricular inversion without transposition of the great vessels in situs inversus.

A classification of one type of congenital malformation previously reported (de la Cruz et al., 1967) is based on the integration of an embryological theory for ventricular inversions with the embryological concepts of trunco-conal malformations (de la Cruz and da Rocha, 1956). In that classification we consider that in each situs, either solitus or inversus ventricular inversions may be associated with: (a) normally arranged great vessels (not transposed); (b) transposition of the great vessels; (c) persistent truncus arteriosus. The patients had ventricular inversion without transposition of the great vessels in situs inversus.THE CORRECT ANATOMICAL DIAGNOSIS WAS NOT FORESEEN BUT THE PHYSIOPATHOLOGICAL DIAGNOSIS WAS CORRECT: pulmonary ischaemia associated with septal defects. In one case these facts were substantiated by catheterization and by angiocardiographic findings which led us to advise surgery. Haemodynamically isolated inversion of the ventricles is as severe a malformation as complete (not corrected) transposition of the great vessels. However, an operation of the anastomotic type between a systemic vessel and the narrow pulmonary artery seemed justified in these cases, as a means to convey more blood to the lungs and improve the saturation of the arterial blood. It was unsuccessfully carried out in one patient.The anatomical, radiological, and electrocardiographic features which might aid in the diagnosis are analysed.

Adult↗

Accurate detection of triple vessel disease in patients with exercise induced ST segment depression after infarction.

The severity of coronary artery disease is an important determinant of prognosis after acute myocardial infarction. The ability of a symptom limited exercise test to predict the presence of triple vessel disease was assessed in 221 patients three weeks after infarction. Coronary angiography was performed in patients with exercise induced ST segment depression. The presence of ST segment depression alone was poorly indicative of triple vessel disease; however, some specific features of ST segment changes on exercise were of predictive value. Downsloping ST segment configuration alone or horizontal ST segment depression associated with an early onset and a late recovery time after exercise correctly identified 30 (90%) of 33 patients with triple vessel disease whereas it incorrectly identified only 6 (15%) of 39 patients with single and double vessel disease. An abnormal blood pressure response was also predictive. In patients with ST segment depression after infarction triple vessel disease can be detected accurately by a combination of the electrocardiographic and haemodynamic variables attained on exercise.

Adrenergic beta-Antagonists↗

Atherosclerotic coronary lesions with inadequate compensatory enlargement have smaller plaque and vessel volumes: observations with three dimensional intravascular ultrasound in vivo.

OBJECTIVE: To compare vessel, lumen, and plaque volumes in atherosclerotic coronary lesions with inadequate compensatory enlargement versus lesions with adequate compensatory enlargement. DESIGN: 35 angiographically significant coronary lesions were examined by intravascular ultrasound (IVUS) during motorised transducer pullback. Segments 20 mm in length were analysed using a validated automated three dimensional analysis system. IVUS was used to classify lesions as having inadequate (group I) or adequate (group II) compensatory enlargement. RESULTS: There was no significant difference in quantitative angiographic measurements and the IVUS minimum lumen cross sectional area between groups I (n = 15) and II (n = 20). In group I, the vessel cross sectional area was 13.3 (3.0) mm2 at the lesion site and 14.4 (3.6) mm2 at the distal reference (p < 0.01), whereas in group II it was 17.5 (5.6) mm2 at the lesion site and 14.0 (6.0) mm2 at the distal reference (p < 0.001). Vessel and plaque cross sectional areas were significantly smaller in group I than in group II (13.3 (3.0) v 17.5 (5.6) mm2, p < 0.01; and 10.9 (2.8) v 15.2 (4.9) mm2; p < 0.005). Similarly, vessel and plaque volume were smaller in group I (291.0 (61.0) v 353.7 (110.0) mm3, and 177.5 (48.4) v 228.0 (92.8) mm3, p < 0.05 for both). Lumen areas and volumes were similar. CONCLUSIONS: In lesions with inadequate compensatory enlargement, both vessel and plaque volume appear to be smaller than in lesions with adequate compensatory enlargement.

Coronary Angiography↗