Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “RESPIRATION”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93Linked to original sources

In vitro Na+,K+-ATPase (EC 3.6.1.3)-dependent respiration and protein synthesis in skeletal muscle of pigs fed at three dietary protein levels.

1. Eighteen pigs were offered diets containing 130, 170 or 210 g protein/kg with three barrows and three gifts per diet from 20 to 60 kg live weight. Oxygen consumption, Na+,K+-ATPase (EC 3.6.1.3)-dependent and -independent respiration and protein synthesis were measured in vitro in intercostal and sartorius muscle preparations from these pigs. 2. Increasing dietary protein concentration increased (P less than 0.01) daily gain and dissectible muscle in carcass. 3. O2 consumption and Na+,K+-ATPase-dependent respiration of the intercostal and sartorius muscles increased linearly (P less than 0.01) with increase in dietary protein concentration. The requirement for the support of the transport of Na+ and K+ across the cell membrane in these muscles, on average, accounted for 22-25% of the O2 consumption. 4. Synthesis rate (mg/g per d) of protein in the sartorius muscle increased (P less than 0.05) from 3.05 to 5.07 and increased (P less than 0.1) from 2.57 to 4.06 in the intercostal muscle as dietary protein increased from 130 to 210 g/kg diet. 5. Regression of Na+,K+-ATPase-dependent respiration against protein synthesis in each of intercostal and sartorius muscles showed a linear relation, an attestation of a close link between productive processes and auxiliary energy expenditure.

Animals↗

The prediction of recommended energy expenditure for an 8 h work-day using an air-purifying respirator.

Thirty railway workers executed maximal, or near maximal, stress tests with and without the use of a half mask air-purifying respirator (Spasciani 85 A1 P1) fitted with two combined filters for simultaneous protection from organic vapours and particulate matter. The pressure-flow characteristics of inspiratory and expiratory resistance at airflows in the range 0-90 l.min-1 were established by a continuous flow method on one test mask. Significant differences were found by paired t-test between the two exercises (with and without use of mask), showing reduced values with use of the mask, for breath frequency, ventilation rate, oxygen uptake, carbon dioxide production, maximal oxygen uptake, percentage of maximal voluntary ventilation used at the maximal exercise ventilation. No significant differences were found for tidal volume, respiratory quotient, heart rate, systolic blood pressure, oxygen uptake at anaerobic threshold, and duration of exercise. The predicted energy expenditure recommended for an 8 h work shift, corresponding to 40% of maximal oxygen uptake, is found to be reduced working with respirator and is significantly different from that observed during stress test without mask. The average ventilation rate at this workload is below 25 l.min-1, with predicted inspiratory mouth pressure equal to, or less than, 20 mm H2O. This maximal inspiratory mouth pressure is proposed as a safety limit for prolonged work using a respirator, with a recommended energy expenditure close to 40% of maximal oxygen uptake.

Adult↗

Effect of organic synthetic food colours on mitochondrial respiration.

Eleven organic synthetic dyes, currently or formerly used as food colours in Brazil, were tested to determine their effect on mitochondrial respiration in mitochondria isolated from rat liver and kidney. The compounds tested were: Erythrosine, Ponceau 4R, Allura Red, Sunset yellow, Tartrazine, Amaranth, Brilliant Blue, Blue, Fast Red E, Orange GGN and Scarlet GN. All food colours tested inhibited mitochondrial respiration (State III respiration, uncoupled) supported either by alpha-ketoglutarate or succinate. This inhibition varied largely, e.g. from 100% to 16% for Erythrosine and Tartrazine respectively, at a concentration of 0.1 mg food colour per mitochondrial protein. Both rat liver and kidney mitochondria showed similar patterns of inhibition among the food colours tested. This effect was dose related and the concentration to give 50% inhibition was determined for some of the dyes. The xanthene dye Erythrosine, which showed the strongest effect, was selected for further investigation on mitochondria in vivo.

Animals↗

Degradation of atrazine, metolachlor, and pendimethalin in pesticide-contaminated soils: effects of aged residues on soil respiration and plant survival.

This study was conducted to determine the effects of pesticide mixtures on degradation patterns of parent compounds as well as effects on soil microbial respiration. Bioavailability of residues to sensitive plant species was also determined. Soil for this study was obtained from a pesticide-contaminated area within an agrochemical dealer site. Degradation patterns were not affected by the presence or absence of other herbicides in this study. Atrazine concentrations were significantly lower at 21 through 160 days aging time compared to day 0 concentrations. Metolachlor and pendimethalin concentrations were not significantly different over time and remained high throughout the study. Microbial respiration was suppressed in treated soils from day 21 to day 160. Soybean and canola were the most successful plant species in the germination and survival tests. Generally, with increased aging of pesticides in soil, germination time decreased. Survival time of plants increased over time for some treatments indicating possible decreased bioavailability of pesticide residues. In some cases, survival time decreased at the longer 160-day aging period, possibly indicating a change in bioavailability, perhaps as the result of formation of more bioavailable and phytotoxic metabolites. No interactive effects were noted for mixtures of pesticides compared to individually applied pesticides in terms of degradation of the parent compound or on seed germination, plant survival, or microbial respiration.

Acetamides↗

A quantitative in vitro fluorescence imaging method for phospholipid loss from respirable mineral particles.

Respirable quartz and kaolin particles were treated with fluorescent-labeled phospholipids to model contact of fibrogenic and nonfibrogenic particles with pulmonary surfactant in the alveolar regions of the lung. Particles were used to challenge rat pulmonary macrophages in vitro at times from 1 d to 10 d. The objective was to develop a quantitative method to track surfactant components that adsorb to respirable particles in the lung or inside cells. Confocal laser scanning microscopy was used to image and quantify surfactant remaining on particles internalized by cells. Results indicate that the fluorescent label is removed from quartz particles quickly, with the fluorescence intensity less than 15% of initial value at 3 d, and about 5% at 10 d. In contrast, the kaolin particle-associated fluorescence was still approximately 39% of initial intensity at 3 d, and 10-15% at 10 d. Unchallenged cells showed a background of approximately 5%, and noninternalized particles did not exhibit any loss of fluorescence over the 10-d exposure. The results indicate the method may be useful in label-removal rate studies of respirable particles in vitro, with some cautions and limitations. Results are discussed and compared with similar studies using nonimaging techniques.

Air Pollutants, Occupational↗

Horizontal diffusion elutriation: a new size-separation technique for preparation of rodent-respirable fibers for animal testing.

Short-and long-term animal experiments are used to examine the toxicology and biopersistence of various types of fibers. In order to ensure an adequate exposure dose for testing, modern experimental protocols specify that the exposure aerosol (in an inhalation test) or the fibers (in an intratracheal instillation [IT] test) must contain at least a minimum concentration of long (> 20 mum) rodent-respirable fibers. As produced and handled, most fibers contain a distribution of diameters and lengths, only some of which are both long and rodent-respirable. Therefore, it is necessary to size-separate the fibers to enrich the proportion of long, rodent-respirable fibers in the material to be tested. This article presents a new and relatively simple method for size separation that avoids some of the difficulties associated with other methods. The method, termed horizontal diffusion elutriation (HDE), is illustrated by size-separating refractory ceramic fiber (RCF) and four polycrystalline alumina (PCA) fibers.

Aluminum Oxide↗

Oxygen dynamics in crude oil contaminated salt marshes: I. Aerobic respiration model.

A simple model was developed to predict oxygen demand exerted by aerobic biodegradation of spilled crude oil and fertilizer added to stimulate biodegradation in salt marsh sediment. The role of aerobic respiration (AR) was determined using first-order G kinetics. The G kinetic rate constants were calculated from laboratory data sets through linear regression. The effect of oil and fertilizer on AR was quantified by comparing three treatments: (i) control (no oil and fertilizer amended), (ii) fertilized, and (iii) oiled and fertilized sediments. The effects of dissolved oxygen concentration in the overlying water and surface mass transfer coefficient were investigated. Aerobic respiration was strongly dependent on the overlying dissolved oxygen concentration when crude oil and fertilizer were added. Oiled/fertilized cores did not show higher SOD and AR than control cores when overlying DO concentration dropped below 5 mg l(-1). Results indicate that higher aerobic respiration in oiled/fertilized is exerted by aerobic biodegradation of crude oil and that major biodegradation of crude oil occurs only when DO level is high (> 5 mg l(-1)).

Accidents↗

Effect of phosphogypsum on respiration and methane emissions in sediment.

The impact of adding phosphogypsum (PG) to freshwater wetland areas, and potential effect on methane production and respiration in sediment was studied in the laboratory. Two organic matter levels (native and enriched with 0.5% by weight ground dry plant material) were studied using five sediment treatments each: (1) no PG added, (2) 4% PG by dry weight (homogenized), (3) 20% PG by dry weight (homogenized), (4) 2000 kg ha(-1) (surface applied), and (5) 5000 kg ha (surface applied), and the experiment was run in triplicate. There was a net flux of methane into sediment for all treatments that were maintained at the native organic matter level, indicating net methane oxidation. In the organic-enriched cores, both of the homogenized treatments exhibited no methane emissions, while the surface applied treatments retained the potential for high emissions. Soil respiration was depressed in all treatments when compared to controls, especially in the organic-enriched cores. The results conclude that it may be possible to add PG to non-vegetated areas with few observable effects on sediment respiration, but organic matter content and method of application are critical concerns.

Calcium Sulfate↗

Electrostatic respirator filter media: filter efficiency and most penetrating particle size effects.

New electrostatic filter media has been developed for use in 42 CFR 84 negative pressure particulate respirator filters. This respirator filter media was not available for evaluation prior to the change from 30 CFR 11 to 42 CFR 84. Thus, characterization of this filter media is warranted. In this study, the new 42 CFR 84 electrostatic respirator filters were investigated with respect to filter penetration and most penetrating particle size. Three different models of N95 filters, along with one model each of the N99, R95, and P100 class filters were used in this study. First, three of each filter were loaded with a sodium chloride (NaCl) aerosol, and three of each filter were loaded with a dioctyl phthalate (DOP) aerosol to obtain normal background penetration results for each filter. Then, two new filters of each type were dipped in isopropanol for 15 seconds and allowed to dry. This isopropanol dip should reduce or eliminate any electrostatic charge on the fibers of each filter, as reported in the technical literature. These dipped filters, along with controls of each filter type, were tested on a TSI 8160 filter tester to determine the most penetrating particle size. These same filters were then tested against a NaCl aerosol to get final penetration values. Electret filters rely heavily on their electrostatic charge to provide adequate filter efficiencies, and correlations between penetration and a filter's electrostatic characteristics are found in the technical literature. In all six of the filter models tested, filter penetration values increased considerably and the most penetrating particle size noticeably shifted toward larger particles. These results are important in better understanding how these new filter materials perform under various conditions, and they indicate the need for additional research to define environmental conditions that may affect electrostatic filter efficiency.

Equipment Design↗

Analysis of sampling line bias on respirable mass measurement.

This study investigated the bias introduced by an inlet sampling line on a respirable mass monitor. The 1.5-m electrically conductive, flexible sampling line conducts aerosol at a flow rate of 2.2 Lpm from a helmet-mounted inlet to a waist-mounted sensor for mass concentration measurement. Particulate transport was modeled for each section of the sampling line and considered the effects of diffusion, gravitational settling, and inertial impaction. An estimate of respirable mass concentration measured with the sampling line was determined by integrating assumed workplace aerosols with the transport curves. The bias introduced by the sampling line was then calculated by dividing the difference between the respirable mass concentration with and without the sampling line by that without the sampling line. For the current sampling line, in which the inner diameter is 4.83 mm, bias was calculated as -0.3 percent, -2.4 percent, -4.6 percent, and -6.7 percent for four test aerosols with mass median aerodynamic diameters of 0.6 microm, 4 microm, 12 microm, and 30 microm, respectively. Optimization studies suggest that increasing the sampling line with a larger inner diameter by a factor of 1.25 to 1.75 will minimize bias to below -3.0 percent. An experimental study confirmed that bias due to the presence of the sampling line is small.

Aerosols↗

Development of a new respirator for organic vapors with a breakthrough detector using a semiconductor gas sensor.

A method for determining breakthrough of organic vapors in a respirator cartridge was developed. A thick film semiconductor gas sensor was used as a breakthrough detector. Air containing organic vapor was introduced into the cartridge, and an output signal from the sensor inserted in the downstream flow of the cartridge was recorded on an IC card. Simultaneously, the breakthrough curve was obtained by measuring the vapor concentration at downstream from the respirator cartridge with a gas chromatograph (GC) equipped with a flame ionization detector. When the breakthrough was almost completed, the data recorded in the card were transferred to a personal computer and the change in the output signal from the sensor was compared with the breakthrough curve obtained by the GC. Twelve organic solvents including aromatic hydrocarbons, chlorinated hydrocarbons, acetates, alcohols, ketones, and aliphatic hydrocarbons were tested under low (20%-25%) and high (70%-80%) relative humidity ranges. The sensitivity of the sensor for chlorinated hydrocarbons such as 1,1,1-trichloroethane was relatively low, especially when the relative humidity was high, but the rise time of the sensor output signal was almost the same as or earlier than the breakthrough time by the GC. Based on the experimental results, a new respirator for organic vapors that can detect the end of service life was developed.

Chromatography, Gas↗

Effects of the local anesthetic bupivacaine on mitochondrial energy metabolism: change from uncoupling to decoupling depending on the respiration state.

The local anesthetic bupivacaine has been found to uncouple oxidative phosphorylation. However, the precise mechanisms of bupivacaine uncoupling have not been elucidated. In the present paper, we demonstrate that the uncoupling effect of the local anesthetic depends on the respiration state. In state 4-respiration (no ADP phosphorylation), bupivacaine acts as a true protonophoretic uncoupler. On the other hand, in state 3-respiration (ADP phosphorylation), bupivacaine induces a change in proton pump stoichiometry and appears to be a decoupler (slip inducer). Moreover, at high concentration, the local anesthetic inhibits the respiratory chain itself. Thus, the divergent reports in the literature on the action of bupivacaine show in fact the various mechanisms by which the local anesthetic may alter mitochondrial energy metabolism.

Adenosine Diphosphate↗

Measuring performance of a half-mask respirator in a styrene environment.

A workplace protection factor (WPF) study was conducted with a half-mask air-purifying respirator during fiber glass boat production. Styrene was the measured analyte, and the geometric mean WPF found was 39.7. Analytical detection limits, sample contamination, and pulmonary elimination from previous exposures or from skin absorption were identified as important considerations that can bias the WPFs measured. There were significant differences in the mean concentrations found inside the respirator when analyzed by time period. An increase in the concentration found inside the facepiece cavity and a decrease in the WPF over time was found for people with three or four measurements. This indicates either a change in performance of the respirator over time or a bias from low-level exposures during the day or skin absorption.

Air Pollutants, Occupational↗

Effect of external dead volume on performance while wearing a respirator.

Respirator dead volume accumulates exhaled carbon dioxide and returns it to the respiratory system during subsequent inhalations. Because inhaled carbon dioxide is known to be a powerful respiratory stimulant and psychoactive gas, respirator dead volume would be expected to influence performance times while respirators are worn during work. This experiment was performed at intense levels of treadmill walking (80-85% VO2max) to demonstrate maximum sensitivity to respiratory stress. Six dead volume conditions (representing a range of 280 to 1,160 mL) were imposed on the subjects. Results show linear decreases in performance times and breathing apparatus comfort with increasing dead volumes. For each 350 mL of external dead volume, a 19% decrease of performance time and an 18% decrease in breathing apparatus comfort can be expected.

Acidosis, Respiratory↗

Respirator cartridge test system and test results for benzene and acrylonitrile.

NIOSH approves organic vapor respirator cartridges based upon testing against 1000 parts per million carbon tetrachloride vapors. Data for other organic vapors are necessary for proper use of organic vapor cartridge respirators against those vapors. This paper describes a system designed to test respirator cartridges and canisters and results of cartridge tests against benzene and acrylonitrile at a variety of concentrations.

Acrylonitrile↗

Physiological response to "pressure-demand" respirator wear.

This investigation determined cardiorespiratory responses of subjects with normal lung function and exercise tolerance and compared them with subjects with moderate impairment of lung function and exercise tolerance. The respirator was an air-line full-face mask (MSA-Ultravue) "pressure-demand" breathing type equipped with an inspiratory resistance of 85 mmH2O at 85 L/min air flow. This resistance was operable in conjunction with the fixed 25 mmH2O inspiratory and expiratory resistance required to pressurize the face piece. Physiologically and subjectively the response of the normal and moderately impaired subjects to respirator wear during rest, 35%, 50% and 80% of their maximal aerobic capacity (VO2max) were not different. However, the pressure swings inside the face piece exceeded 24 cmH2O and resulted in 50% of the subjects being unable to finish 10 minutes of work at 80% VO2max. The greater the ventilatory demand placed upon the respirator due to increasing workload, the more like a "demand" system pressure-flow response the "pressure-demand" system produced. Hence, the concept of increased protection and reduced inspiratory resistance as a result of pressurizing the facepiece during heavy work is seriously questioned.

Adult↗

Determination of critical anthropometric parameters for design of respirators.

The objectives of this study were 1) to collect useful anthropometric data from 243 workers fit-tested in a continuing respirator fit-test program; and 2) to determine correlation between anthropometric data and Protection Factor obtained from quantitative fit-testing for half-mask respirators. Anthropometric data were collected from two direct facial measurements [nasal root breadth (NRB), and face-length (FL)] and five indirect facial measurements [nose length, nose protrusion, chin length, mouth width (MW), and face width (FW)] from front- and side-view slides of test subjects. For quantitative analysis, the anthropometric data collected in this study were normalized with relevant respirator dimensions (for four different brands and ten sizes). Results of linear regression analysis indicated that correlation coefficients between Protection Factor and anthropometric data (FL, MW, FW and NRB) were respectively - 0.04, 0.22, 0.30 and 0.04. These correlation coefficients are for white males without facial hair. The "critical" anthropometric parameters as apparent from the analysis were MW and FW. However, a person with certain combination(s) of multiple anthropometric parameters may provide a better correlation with Protection Factor.

Anthropometry↗

Computing partial-shift respirator use periods.

Occasionally, airborne contaminant concentrations cannot be reduced to desired levels, even after the installation of feasible engineering controls. The industrial hygienist may have to recommend full-shift or partial-shift use of appropriate respirators to reduce exposures. The method described allows the industrial hygienist to recommend the minimum period of time an exposed employee needs to use a respirator in order to reach the desired exposure level. The procedure is based on the calculation of Time-Weighted Averages, using the upper confidence levels of air sampling data, and the respirator protection factors.

Air Pollutants↗