Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Friction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93Linked to original sources

Nanotribological and nanomechanical characterization of human hair using a nanoscratch technique.

Human hair ( approximately 50-100 microm in diameter) is a nanocomposite biological fiber with well-characterized microstructures, and is of great interest for both cosmetic science and materials science. Characterization of nanotribological and nanomechanical properties of human hair including the coefficient of friction and scratch resistance is essential to develop better shampoo and conditioner products and advance biological and cosmetic science. In this paper, the coefficient of friction and scratch resistance of Caucasian and Asian hair at virgin, chemo-mechanically damaged, and conditioner-treated conditions are measured using a nanoscratch technique with a Nano Indenter II system. The scratch tests were performed on both the single cuticle cell and multiple cuticle cells of each hair sample, and the scratch wear tracks were studied using scanning electron microscopy (SEM) after the scratch tests. The effect of soaking on the coefficient of friction, scratch resistance, hardness and Young's modulus of hair surface were also studied by performing experiments on hair samples which had been soaked in de-ionized water for 5 min. The nanotribological and nanomechanical properties of human hair as a function of hair structure (hair of different ethnicity), damage, treatment and soaking are discussed.

Black People↗

Tractive forces during rolling motion of the knee: implications for wear in total knee replacement.

Wear at the polyethylene tibial plateau in total knee arthroplasty (TKR) is one of the primary concerns with these devices. The artificial bearing of a TKR has to sustain large forces while allowing the mobility for normal motion, typically, rolling, gliding and rotation. The tractive forces during the rolling motion at the knee joint were analyzed to determine which factors cause these forces to increase in TKR. The implications of these tractive forces to polyethylene wear were considered. Traction forces were calculated using a model of the knee to evaluate the effect of variations in the coefficient of friction, gait characteristics, antagonistic muscle contraction and patellofemoral mechanics. The model was limited to the sagittal plane motion of the femur on the tibia. The input for the model was the shape of the articulating surface, coefficient of friction, contact path, muscle anatomy and gait kinetics common to patients with a total knee replacement. The generation of tractive forces on the tibial polyethylene plateau was highly dependent on the static and dynamic coefficient of friction between the femur and the tibia. A peak tractive force of approximately 0.4 body weight was calculated with a peak normal force of 3.3 body weight. Tractive rolling occurred during most of stance phase when the static coefficient was 0.2. Alterations in gait patterns had a substantial effect on the generation of tractive forces at the knee joint. When an abnormal gait pattern (often seen following TKR) was input to the model the posteriorly directed tractive force on the tibial surface was reduced. It was also found that variations in muscle contractions associated with antagonistic muscle activity as well as the angle of pull of the patellar tendon affected the magnitude of tractive forces. The results of the study suggest that there are feasible conditions following total knee replacement which can lead to tractive forces during rolling motion at the tibiofemoral articulation that should be considered in the analysis of factors leading to polyethylene damage in total knee replacement.

Feasibility Studies↗

Lubrication of saliva substitutes at enamel-to-enamel contacts in an artificial mouth.

Mechanisms of salivary lubrication can be quantitatively measured by a reduction in the coefficient of friction. It is important that lubrication be assessed under the conditions of the oral cavity to properly assess lubrication regimes. The relative lubricity of three artificial salivas and two controls were assessed at a bovine enamel interface in an artificial mouth with a range of conditions that approximate oral function. Statistical analysis indicated that the enamel lubricity of sodium dodecylsulfate (SDS) and Oracare-D saliva substitutes were different from the other saliva substitutes and water. The low friction with Oracare-D and SDS saliva substitutes was because of resident amphipaths adsorbed at the enamel interface. Amphipaths adsorbed on enamel may provide a reduction in interocculsal friction and its resulting complications for patients with xerostomia.

Animals↗

Molecular weight independence of the effect of additive hyaluronic acid on the lubricating characteristics in synovial joints with experimental deterioration.

OBJECTIVE: To assess the molecular weight dependence of the lubricating characteristics of additive hyaluronic acid in animal joints with experimental deterioration. DESIGN: An experimental study in rabbits stifles in vitro. BACKGROUND: Hyaluronic acid is used as a drug for osteoarthritis. However, the molecular weight dependence of the effect of hyaluronic acid has been unclear. METHODS: Using a robotic arm under force-control, frictional coefficients were measured in fourteen rabbit stifles. The experimental conditions examined were: (1) intact joint surfaces; (2) after the joint surfaces were washed with physiological saline; (3) after the addition of 1% hyaluronic acid solution with a molecular weight of one million daltons and two million daltons, respectively. RESULTS: The increased frictional coefficient produced by washing with saline was decreased significantly by the addition of hyaluronic acid to the joint surfaces. This effect was observed regardless of the molecular weight of the hyaluronic acid. CONCLUSION: The lubricating characteristics of hyaluronic acid in synovial joints do not change with molecular weight. RELEVANCE: Hyaluronic acid solution is used clinically for the treatment of osteoarthritis. In the present study, the molecular weight dependency of the lubricating characteristics of hyaluronic acid was tested using the friction in synovial joints.

Animals↗

Evaluation of titanium brackets for orthodontic treatment: part I. The passive configuration.

The static and kinetic frictional coefficients of commercially pure titanium brackets were evaluated in the passive configuration in the dry and wet states against stainless steel, nickel-titanium, and beta-titanium arch wires. For comparison, stainless steel brackets were evaluated under identical conditions. Titanium brackets were grayer in color and rougher in texture than the stainless steel brackets. Bracket slots were up to 0.002 inch greater than the nominally stated values. Remarkably, the static and kinetic frictional coefficients of the couples formed by titanium and stainless steel brackets were comparable. When evaluated against stainless steel and nickel-titanium arch wires in the dry state at 34 degrees C, the static coefficient averaged.12 and.20, respectively, independent of bracket alloy. When evaluated against stainless steel and nickel-titanium wires in the wet state at 34 degrees C using human saliva, the static coefficient averaged.15 and.20, respectively, independent of bracket alloy. Only the beta-titanium arch wires increased by about 15%, when tested in either the dry or the wet state against titanium versus stainless steel brackets. Noteworthy, too, was the decrease of both coefficients in the beta-titanium wire couples from their previously reported values. Analyses of electron spectroscopy for chemical analysis spectra and depth profiles show that these new brackets are titanium only in the bulk. Indeed the immediate surfaces are composed of, at least, 80 atomic percent (at.%) carbon and oxygen; whereas, the titanium that is present (>11 at.%) is mostly in the form of titanium dioxide. The presence of this quite thin passivating layer, which resides on top of an oxygen-hardened titanium substrate, reduces the galling and fretting that would normally be expected in such materials. Pending the outcome of future angulation tests, these frictional measurements show that titanium brackets are not only comparable to stainless steel brackets but also are more biocompatible with nickel having been eliminated from their constitution.

Dental Alloys↗

Electrowetting dynamics of microfluidic actuation.

When voltage is suddenly applied to vertical, parallel dielectric-coated electrodes dipped into a liquid with finite conductivity, the liquid responds by rising up to reach a new hydrostatic equilibrium height. On the microfluidic scale, the dominating mechanism impeding this electromechanically induced actuation appears to be a dynamic friction force that is directly proportional to the velocity of the contact line moving along the solid surface. This mechanism has its origin in the molecular dynamics of the liquid coming into contact with the solid surface. A simple reduced-order model for the rising column of liquid is used to quantify the magnitude of this frictional effect by providing estimates for the contact line friction coefficient. Above some critical threshold of voltage, the electromechanical force is clamped, presumably by the same mechanism responsible for contact angle saturation and previously reported static height-of-rise limits. The important distinction for the dynamic case is that the onset of the saturation effect is delayed in time until the column has risen more than about halfway to its static equilibrium height.

Algorithms↗

Sliding mechanics of coated composite wires and the development of an engineering model for binding.

A tribological (friction and wear) study, which was designed to simulate clinical sliding mechanics, was conducted as part of an effort to determine the suitability of poly(chloro-p-xylylene) coatings for composite orthodontic archwires. Prototype composite wires, having stiffnesses similar to those of current initial and intermediate alignment wires, were tested against stainless steel and ceramic brackets in the passive and active configurations (with and without angulation). Kinetic coefficient of friction values, which were determined to quantify sliding resistances as functions of the normal forces of ligation, had a mean that was 72% greater than uncoated wire couples at 0.43. To improve analysis of the active configuration, a mathematical model was developed that related bracket angulation, bracket width, interbracket distance, wire geometry, and wire elastic modulus to sliding resistance. From this model, kinetic coefficients of binding were determined to quantify sliding resistances as functions of the normal forces of binding. The mean binding coefficient was the same as that of uncoated wire couples at 0.42. Although penetrations through the coating were observed on many specimens, the glass-fiber reinforcement within the composite wires was undamaged for all conditions tested. This finding implies that the risk of glass fiber release during clinical use would be eliminated by the coating. In addition, the frictional and binding coefficients were still within the limits outlined by conventional orthodontic wire-bracket couples. Consequently, the coatings were regarded as an improvement to the clinical acceptability of composite orthodontic archwires.

Aluminum Oxide↗

Autocorrelation of acoustic signals from the temporomandibular joint.

Although there have been many investigations of TMJ sounds in the time and frequency domains, no previous reports have been found of investigations of the autocorrelation spectra of these sounds. In the present study, TMJ sounds were digitized at 1.7 kHz and 300 ms samples containing either clicks (single short duration sounds), crepitus (long duration continuous sounds) or creaks (a series of two or more clicks) were selected. These samples were compared with sounds of known origin: tooth impact sounds, frictional sounds elicited by scratching the head, and bruxing sounds resulting from stick-slip friction as teeth were slid against one another under high pressure. There were clear qualitative and quantitative differences between the autocorrelation spectra of the three types of TMJ sounds. Clicks were similar to tooth impact contact sounds, creaks were similar to the bruxing sounds, and crepitus was similar to the scratching sounds. The repetition rate of creaks was 16 Hz (s.d. 9 Hz), this being similar to the resonance of the mandible about the condylar axis. It is suggested that the creaks are due to stick-slip friction in the lower joint compartment of the TMJ.

Acoustics↗

Physical mechanisms involved in the genesis of temporomandibular joint sounds.

Several different mechanisms are potentially capable of generating sounds in the temporomandibular joint (TMJ). These include impact, sliding and stick-slip friction, fluid dynamic effects and the release of elastic strain energy. It is the aim of this paper to provide a framework with which to separate sounds resulting from the different underlying causes. Each mechanism is described and its relevance to TMJ sounds and clinical significance discussed. Since it is not possible to observe these mechanisms in vivo the arguments are based mainly on analogies which are used to make predictions of the characteristic acoustic signatures of the sounds produced by these different mechanisms. In particular the changes in the characteristics of the sounds as parameters such as mandibular speed and loading are stressed. It is suggested that single short duration sounds (clicks) are due to impact, multiple short duration sounds (creaks) to stick-slip friction and defects of form and long duration sounds (crepitus) to simple sliding friction. Several other mechanisms which have no obvious clinical significance but which are capable of producing similar sounds are also described and methods of distinguishing them from the sounds that do have clinical implications are discussed.

Acoustics↗

Role of uppermost superficial surface layer of articular cartilage in the lubrication mechanism of joints.

The uppermost superficial surface layer of articular cartilage, the 'lamina splendens' which provides a very low friction lubrication surface in articular joints, was investigated using atomic force microscopy (AFM). Complementary specimens were also observed under SEM at -10 degrees C without dehydration or sputter ion coating. Fresh adult pig osteochondral specimens were prepared from the patellas of pig knee joints and digested with the enzymes, hyaluronidase, chondroitinase ABC and alkaline protease. Friction coefficients between a pyrex glass plate and the osteochondral specimens digested by enzymes as well as natural (undigested) specimens were measured, using a thrust collar apparatus. Normal saline, hyaluronic acid (HA) and a mixture of albumin, globulin, HA (AGH) were used as lubrication media. The surface irregularities usually observed in SEM studies were not apparent under AFM. The articular cartilage surface was resistant to hyaluronidase and also to chondroitinase ABC, but a fibrous structure was exhibited in alkaline protease enzymes-digested specimens. AFM analysis revealed that the thickness of the uppermost superficial surface layer of articular cartilage was between 800 nm and 2 microm in adult pig articular cartilage. The coefficient of friction (c.f.) was significantly higher in chondroitinase ABC and alkaline protease enzymes digested specimens. Generally, in normal saline lubrication medium, c.f. was higher in comparison to HA and AGH lubrication media. The role of the uppermost, superficial surface layer of articular cartilage in the lubrication mechanism of joints is discussed.

Animals↗

The distribution of anaerobic energy in 1000 and 4000 metre cycling bouts.

In sprinting events of short duration, performance depends not only on the mean external power output and the frictional losses but also on the distribution of energy over the race. To investigate the optimal distribution of anaerobic energy during cycling the 1000 m time trial and the 4000 m pursuit, we simulated a power equation which contains expressions for the production of aerobic and anaerobic power, for frictional losses and for the rate of change of kinetic energy. Parameters for air- and rolling resistance were derived from the literature and the equations for aerobic and anaerobic power production were based on supra-maximal bicycle ergometer tests. Simulated lap and final times were compared to those realized by the best four athletes during the 1990 World Championships. The mean final times of these athletes of 64.1 s and 272.6 s for the 1000 m and 4000 m respectively were closely approximated by the simulated times of 63.7 s and 281.3 s. The simulations show that performance in the 1000 m race depends to a great extent on a large power output at the onset of the race. Moreover, it is demonstrated that this distance should be cycled in an all out fashion and not with a uniform velocity after the start despite the higher air frictional losses. For the 4000 m pursuit it appears to be more effective to perform a short but powerful start and then continue the race with a constant or only slightly decreasing power output.

Bicycling↗

Lubricating properties of the initial salivary pellicle--an AFM study.

The role of saliva in the oral cavity is manifold; an important function is to serve as lubricant between hard (enamel) and soft (mucosal) tissues. Intraoral lubrication is of crucial importance in order to maintain functions such as deglutition, mastication and the faculty of speech. A large number of people suffer from impaired salivary functions, displaying symptoms such as 'dry mouth'. This results in a need for methods to assess the lubricating properties of both native saliva and potential artificial saliva formulations. Here, normal as well as lateral forces, acting between adsorbed salivary films, have been measured for the first time by means of colloidal probe atomic force microscopy (AFM). It was found that the presence of salivary pellicles between hard surfaces reduces the friction coefficient by a factor of 20. This reduction of friction is consistent with the long-range purely repulsive nature of the normal forces acting between the salivary films. The lubricating mechanism is presumably based on a full separation of the sliding surfaces by the salivary films. The friction between salivary films has been investigated at normal loads that cover the clinical jaw closing forces, and it can be concluded that the lubricating properties are maintained within this load interval. The present study indicates the usefulness of colloidal probe AFM, which offers a direct and quantitative measure of lubrication at a molecular level, in the study of biotribological phenomena. In particular, the results obtained here may have implications for the development of saliva substitutes.

Adult↗

Can loaded interface characteristics influence strain distributions in muscle adjacent to bony prominences?

Pressure distributions at the interface between skin and supporting tissues are used in design of supporting surfaces like beds, wheel chairs, prostheses and in sales brochures to support commercial products. The reasoning behind this is, that equal pressure distributions in the absence of high pressure gradients is assumed to minimise the risk of developing pressure sores. Notwithstanding the difficulty in performing reproducible and accurate pressure measurements, the question arises if the interface pressure distribution is representative of the internal mechanical state of the soft tissues involved. The paper describes a study of the mechanical condition of a supported buttock contact, depending on cushion properties, relative properties of tissue layers and friction. Numerical, mechanical simulations of a buttock on a supporting cushion are described. The ischial tuberosity is modelled as a rigid body, whereas the overlying muscle, fat and skin layers are modelled as a non-linear Ogden material. Material parameters and thickness of the fat layer are varied. Coulomb friction between buttock and cushion is modelled with different values of the friction coefficient. Moreover, the thickness and properties of the cushion are varied. High shear strains are found in the muscle near the bony prominence and the fat layer near the symmetry line. The performed parameter variations lead to large differences in shear strain in the fat layer but relatively small variations in the skeletal muscle. Even with a soft cushion, leading to a high reduction of the interface pressure the deformation of the skeletal muscle near the bone is high enough to form a risk, which is a clear argument that interface pressures alone are not sufficient to evaluate supporting surfaces.

Adipose Tissue↗

Factors influencing restaurant worker perception of floor slipperiness.

Falls are responsible for a substantial injury burden in the global workplace. Restaurant environments are particularly challenged by slips, trips, and falls. This study explored those factors that could influence workers' self-reports of slipperiness in U.S. fast-food restaurants. One hundred and twenty-six workers employed in 10 fast-food restaurants in the northeastern United States participated in the study representing a study-wide response rate of 87.5%. Participants' ratings of floor slipperiness and occupational slip history within the past 4 weeks were collected through written questionnaire. Additional factors collected by questionnaire included age, gender, shift length, and shoe type. Shoe condition (wear) and shoe contamination were visually assessed by the investigators. Floor friction was also measured. Lower restaurant mean coefficient of friction and the presence of contamination on workers' shoe soles were environmental factors significantly associated with workers reporting more slippery conditions. A recent workplace history of slipping with or without a subsequent fall was also significantly associated with workers reporting more slippery conditions. Workers over the age of 45 reported conditions to be significantly less slippery than younger workers. The results suggest that worker ratings of slipperiness are influenced not only by the actual level of friction but also by the other individual and environmental factors noted above. Recommendations for future studies would include a longitudinal design to better capture the temporal sequence between these variables. More field research is needed to better understand the association between workplace conditions, worker perception of slipperiness, and slipping at work.

Accidental Falls↗

Influence of Avicel PH-301 on the compressibility of alpha-methyldopa and phenobarbitone in direct compression.

The aim of this work was to investigate the compressibility behavior of alpha-methyldopa and phenobarbitone using a Korsch EK0 instrumented eccentric tablet machine, with force-time and force-displacement curves constructed and applied to calculate different compressional values to study the compressional behavior. The results of this work revealed a difference in compressibility behavior between the two drugs during the compressional process. alpha-Methyldopa gave an abnormal compressional curve with high friction in the pre- and postcompressional phases. A residual force could be seen on the lower punch. Furthermore, capping and sticking were observed visually during tablet pressing, indicating poor compressibility behavior. In the case of phenobarbitone, no friction was observed in the precompressional phase, but there was higher friction in the postcompressional phase, especially in the ejection phase. The compressibility of the drugs was improved by the addition of Avicel PH-301 and magnesium stearate.

Anticonvulsants↗

An ex-vivo investigation into the effect of bracket displacement on the resistance to sliding.

This ex-vivo study investigated the effect that repeated bracket displacement has on sliding friction and the magnitude of bracket displacement, and hence tooth movement, required to release bracket/archwire binding. The design consisted of an ex-vivo laboratory study. A jig was designed that allowed repeated displacement of a bracket to occur, while the resistance to sliding (friction) was measured using an Instron universal testing machine. One type of stainless steel bracket was used in conjunction with four archwire types (0.016-inch stainless steel, 0.019 x 0.025-inch stainless steel, 0.021 x 0.025-inch stainless steel, 0.019 x 0.025-inch beta-titanium) and four magnitudes of displacement. Repeated bracket displacement has a significant effect on the sliding resistance at the bracket/archwire interface (P < 0.001). The reduction in sliding resistance noted with displacement depended on the archwire. Over the range of displacements tested, there was an 85 and 80 per cent reduction associated with 0.021 x 0.025-inch and 0.019 x 0.025-inch stainless steel, respectively. For 0.019 x 0.025-inch beta-titanium and 0.016-inch stainless steel, these reductions were 27 and 19 per cent, respectively. The importance of true friction, given the likelihood of bracket and/or archwire displacements in vivo, may be lessened.

Analysis of Variance↗

Probabilistic fasteners with parabolic elements: biological system, artificial model and theoretical considerations.

Probabilistic fasteners are attachment devices composed of two surfaces covered with cuticular micro-outgrowths. Friction-based fasteners demonstrate high frictional forces when the surfaces come into contact. Attachment in this case is based on the use of the surface profile and mechanical properties of materials, and is fast, precise and reversible. The best-studied examples composed of parabolic elements are the wing-locking mechanism in beetles and the head arrester in dragonflies. This study combines experimental data of force measurements, obtained in an artificial model system, and theoretical considerations based on the simple model of behaviour of probabilistic fasteners with parabolic elements. Elements of the geometry in both cases correspond to the biological prototypes. Force measurements on the artificial system show that the attachment force is strongly dependent on the load force. At small loads, the increase of attachment is very slow, whereas rapid increase of attachment was detected at higher loads. At very high loads, a saturation of the attachment force was revealed. A simple explanation of the attachment principle is that with an increasing load elements of both surfaces slide into gaps of the corresponding part. This results in an increase of lateral loading forces acting on elements. High lateral forces lead to an increase of friction between single sliding elements. An analytical model which describes behaviour of the probabilistic fasteners with parabolic elements is proposed.

Animals↗

Time scale and other invariants of integrative mechanical behavior in living cells.

In dealing with systems as complex as the cytoskeleton, we need organizing principles or, short of that, an empirical framework into which these systems fit. We report here unexpected invariants of cytoskeletal behavior that comprise such an empirical framework. We measured elastic and frictional moduli of a variety of cell types over a wide range of time scales and using a variety of biological interventions. In all instances elastic stresses dominated at frequencies below 300 Hz, increased only weakly with frequency, and followed a power law; no characteristic time scale was evident. Frictional stresses paralleled the elastic behavior at frequencies below 10 Hz but approached a Newtonian viscous behavior at higher frequencies. Surprisingly, all data could be collapsed onto master curves, the existence of which implies that elastic and frictional stresses share a common underlying mechanism. Taken together, these findings define an unanticipated integrative framework for studying protein interactions within the complex microenvironment of the cell body, and appear to set limits on what can be predicted about integrated mechanical behavior of the matrix based solely on cytoskeletal constituents considered in isolation. Moreover, these observations are consistent with the hypothesis that the cytoskeleton of the living cell behaves as a soft glassy material, wherein cytoskeletal proteins modulate cell mechanical properties mainly by changing an effective temperature of the cytoskeletal matrix. If so, then the effective temperature becomes an easily quantified determinant of the ability of the cytoskeleton to deform, flow, and reorganize.

Adaptation, Physiological↗