Hybrid fluorometric flow analyzer for ammonia.

We describe a robust, highly sensitive instrument for the determination of ambient ammonia. The instrument uses two syringe pumps to handle three liquids. The flow configuration is a hybrid between traditional flow injection (FI) and sequential injection (SI) schemes. This hybrid flow analyzer spends approximately 87% of its time in the continuous flow FI mode, providing the traditional FI advantages of high baseline stability and sensitivity. The SI fluid handling operation in the remaining time makes for flexibility and robustness. Atmospheric ammonia is collected in deionized water by a porous membrane diffusion scrubber at 0.2 L/min with quantitative collection efficiency, derivatized on-line to 1-sulfonatoisoindole, and measured by fluorometry. In the typical range for ambient ammonia (0-20 ppbv), response is linear (r2 = 0.9990) with a S/N = 3 limit of detection of 135 pptv (15 nM for 500 microL of injected NH4+(aq)) with an inexpensive light emitting diode photodiode-based detector. Automated operation in continuously repeated, 8-min cycles over 9 days shows excellent overall precision (n = 1544 p(NH)3 = 5 ppbv, RSD = 3%). Precision for liquid-phase injections is even better (n = 1520, [NH4+(aq)] = 2.5 microM, RSD = 2%). The response decreases by 3.6% from 20 to 80% relative humidity.

Ammonia↗

Application of ganglioside-sensitized liposomes in a flow injection immunoanalytical system for the determination of cholera toxin.

Cholera, an acute infectious disease associated with water and seafood contamination, is caused by the bacterium Vibrio cholerae, which lives and colonizes in the small intestine and secretes cholera toxin (CT), a causative agent for diarrhea in humans. Based on earlier lateral flow assays, a flow injection liposome immunoanalysis (FILIA) system with excellent sensitivity was developed in this study for the determination of CT at zeptomole levels. Ganglioside (GM1), found to have specific affinity toward CT, was inserted into the phospholipid bilayer during the liposome synthesis. These GM1-sensitized, sulforhodamine B (SRB) dye-entrapping liposomes were used as probes in the FILIA system. Anti-CT antibodies were immobilized in its microcapillary. CT was detected by the formation of a sandwich complex between the immobilized antibody and GM1 liposomes. During the assay, the sample was introduced first into the column, and then liposomes were injected to bind to all CT captured by the antibody in the microcapillary. Subsequently, the SRB dye molecules were released from the bound liposomes via the addition of the detergent octyl glucopyranoside. The released dye molecules were transported to a flow-through fluorescence detector for quantification. The FILIA system was optimized with respect to flow rate, antibody concentration, liposome concentration, and injected sample volume. The calibration curve for CT had a linear range of 10-16 to 10-14 g mL-1. The detection limit of this immunosensor was 6.6 x 10(-17) g mL-1 in 200-microL samples (equivalent to 13 ag or 1.1 zmol).

Antibodies↗

Analytical solutions of the ideal model for gradient liquid chromatography.

The analytical solutions of the ideal model for gradient elution that ignores the influence of the solute concentration on the retention factor (k) were studied by using the method of characteristics for solving partial differential equations. It is found for any gradient profiles and solvent strength models used that the concentration of the solute will be discontinuous where the mobile-phase composition is. On a given characteristic curve, the product of the concentration and the retention factor is kept constant at the point where the concentration is continuous. At the point where the concentration is discontinuous, the product on the left side of this point is equal to that on the right side. We also discussed the basic equations to predict the retention time in gradient elution and introduced the injection time into them. For linear solvent strength stepwise and linear gradient elution, general expressions were proposed for the prediction and they can be used as the basis to derive others for specific gradient modes such as single linear, stepwise, and ladderlike gradients. For these modes, simple expressions to account for the band compression and the concentration change during the elution were also given.

Algorithms↗

Flow injection renewable surface immunoassay for real time monitoring of biospecific interactions.

An automated system for performing rapid immunoassay, kinetic measurements, and affinity ranking of biomolecular interactions using fluorescence-labeled ligands is described. Its distinctive feature is the automated renewal of solid phase for each measurement, which avoids the need for regeneration of the sensing surface. This system--flow injection renewable surface immunoassay (FIRSI)--is used for the first time here for determination of rate constants for an antibody/antigen interaction and for affinity ranking of several related antigens against one antibody. The performance of the system is compared with a commercial BIAcore system that uses surface plasmon resonance for monitoring biomolecular interactions. While the values of association and dissociation rate constants for human serum albumin (HSA) with monoclonal anti-HSA antibody obtained by these techniques were comparable, it is shown that the FIRSI techniques requires simpler instrumentation, handles a broader size range of analytes, and does not suffer from disturbances caused by changes in the refractive index.

Animals↗

A flow injection microdialysis sampling chemiluminescence system for in vivo on-line monitoring of glucose in intravenous and subcutaneous tissue fluid microdialysates.

A novel flow injection on-line microdialysis system for in vivo monitoring of glucose in subcutaneous tissue fluid and blood is described. An implantable loop-type microdialysis probe was used for subcutaneous sampling, and a flow-through microdialyzer was used for intravenous sampling by pumping of the blood from the tested rabbit through the microdialyzer located outside the living system at a flow rate of 10 microL/min. The perfusion rate of the dialysate was 20 microL/min. The glucose in the dialysate was detected on-line with a flow injection chemiluminescence system after passing through an immobilized glucose oxidase reactor. The calibration of the detector system (including reactor) and monitoring of baseline drifts were performed simultaneously to improve the reliability of the monitoring process. The dialysate sample volume was 20 microL, and the sample throughout was 28 h-1. The variation of glucose level in subcutaneous tissue fluid and blood of the rabbits was monitored after the administration of glucose or insulin to demonstrate the favorable resolution and reliability of the system for in vivo on-line monitoring.

Animals↗

Gas chromatograph injection liner for continuous analyte admission into a mass spectrometer.

An inexpensive modification to a gas chromatography injector liner is reported that facilitates continuous admission of analyte into a gas chromatograph/mass spectrometer (GC/MS) for methods development. The MS methods development liner can be made by making simple modifications to commercially available liners and fits into standard injectors in place of the normal liners without any need to break vacuum in the MS. The injector temperature and gas flow rates are adjusted to provide appropriate analyte levels in the MS, which can be admitted under conditions identical with those of real analyses, including co-admission of column bleed. The device is particularly useful for development of tandem MS methods in GC/MS/MS instruments, which are configured with the GC as the sole sample inlet.

Flow Injection Analysis↗

Flow injection monitoring of aflatoxin M1 in milk and milk preparations using filter-supported bilayer lipid membranes.

This work describes a technique for the rapid and sensitive electrochemical flow injection monitoring of aflatoxin M1 (AFM1) using stabilized systems of filter-supported bilayer lipid membranes (BLMs). Injections of AFM1 were made into flowing streams of a carrier electrolyte solution, and a transient current signal with a duration of seconds reproducibly appeared less than 10 s after exposure of the lipid membranes to the toxin. The magnitude of this signal was linearly related to the concentration of AFM1, with detection limits at the subnanomolar level. The mechanism of signal generation was investigated by differential scanning calorimetric experiments. The technique was applied for the rapid flow injection determination of AFM1 in milk and milk preparations. The effect of potent interferences such as proteins and lipids was investigated, and the results show that interferences from these milk constituents can be eliminated by modulation of the flow rate of the carrier solution so as not to allow adsorption of these compounds in BLMs. AFM1 could be determined in continuous flowing systems with a rate of at least 4 samples min-1. Repetitive cycles of injection of AFM1 showed no signal degradation during each cycle.

Aflatoxin M1↗

Bioelectrochemical monitoring of phenols and aromatic amines in flow injection using novel plant peroxidases.

An amperometric flow system combined with a glucose oxidase-mutarotase reactor was optimized and used to determine aromatic amines and phenols using peroxidase-modified graphite electrodes. An increase in currents upon injection of the analyzed substrate was shown to be approximated by a Michaelis-Menten type dependence. The detection limit was calculated as 3 times the noise, and the sensitivity was calculated as Imax/K(m)app. Commercially available horseradish peroxidase was compared with tobacco anionic and peanut cationic peroxidases for determination of aromatic amines and phenols. Detection limits of 10 nM for determination of o-aminophenol and o- and p-phenylenediamine achieved with a tobacco peroxidase-modified electrode give a promise for further improvements in sensitivities and detection limits of biosensors.

Aniline Compounds↗

Automated flow injection gradient technique for binding studies of micromolecules to proteins using potentiometric sensors: application to bovine serum albumin with anilinonaphthalenesulfonate probe and drugs.

An automated flow injection (FI) gradient technique is described for the binding study of the potentiometric probe 1-anilino-8-naphthalenesulfonate (ANS) to bovine serum albumin (BSA). Using a single-channel FI system with a mixing chamber and a flow ANS electrode, the binding parameters (binding constant and number of binding sites) were calculated using the Scatchard model. The concentration gradient was calibrated by injecting ANS in the stream, and the binding experiment was performed by injecting ANS-BSA solution in the carrier solution of equal albumin concentration. The equations describing the concentration gradient and the corresponding electrode potential curve are presented. A systematic study of the factors affecting the complexation equilibrium and the electrode response was performed. For the ANS binding to BSA, two binding classes were determined with binding constants of (2.1 +/- 0.3) x 10(5) and (3.3 +/- 0.8) x 10(3) M-1 and 3.8 +/- 0.6 and 10 +/- 2 binding sites per class, respectively, at 27 +/- 1 degrees C, in 0.10 M phosphate pH 7.4. Competitive binding experiments of sulfamethoxazole, salicylate, azapropazone, ketoprofen, and tolmetin to albumin were also performed by monitoring ANS binding inhibition (decrease of apparent binding constant). This technique takes advantage of FI gradients and direct potentiometry and utilizes the total information contained in FI peaks, providing fast and accurate binding information in a wide range of concentration ratios.

Anilino Naphthalenesulfonates↗

A flow injection renewable surface technique for cell-based drug discovery functional assays.

A novel flow injection-renewable surface (FI-RS) technique is introduced for the execution of automated pharmacology-based assays on living cells. Cells are attached to microcarrier beads, which serve as the disposable and renewable surface with which the assay is performed. The feasibility of this FI-RS technique is demonstrated by performing a functional assay using Chinese hamster ovary cells transfected with the rat muscarinic receptor (M1). The intracellular calcium elevation resulting from the agonist-receptor interaction is measured via a calcium-sensitive fluorescent probe (fura-2) and a fluorescence microscope photometry system. The FI apparatus allows reproducible and precise control of the concentration gradient of chosen muscarinic receptor agonists (carbachol, acetylcholine, pilocarpine) delivered to cells attached to microcarrier beads. The RS methodology eliminates problems associated with diminishing biological response vis-à-vis traditional functional assays that are performed repetitively on the same group of cells. Using this technique, reproducible responses are measured and pharmacologic parameters quantified that compare favorably to literature values. In addition, the use of the FI-RS functional assay as an analytical method for discrimination of agonists based on kinetic parameters is proposed.

Animals↗

Amperometric biosensor for glutamate using prussian blue-based "artificial peroxidase" as a transducer for hydrogen peroxide.

The specially deposited Prussian Blue denoted as "artificial peroxidase" was used as a transducer for hydrogen peroxide. The electrocatalyst was stable, highly active, and selective to hydrogen peroxide reduction in the presence of oxygen, which allowed sensing of H2O2 around 0.0 V (Ag/AgCl). Glutamate oxidase was immobilized on the surface of the Prussian Blue-modified electrode in a Nafion layer using a nonaqueous enzymology approach. The calibration range for glutamate in flow injection system was 1 x 10(-7)-1 x 10(-4) M. The lowest concentration of glutamate detected (1 x 10(-7) M) and the highest sensitivity in the linear range of 0.21 A M-1 cm-2 were achieved. The influence of reductants was practically avoided using the low potential of an indicator electrode (0.0 V Ag/AgCl). The attractive performance characteristics of the glutamate biosensor illustrate the advantages of Prussian Blue-based "artificial peroxidase" as transducer for hydrogen peroxide detection.

Biosensing Techniques↗

Solvent extraction coupled on-line to a reversed micellar mediated chemiluminescence detection system for trace-level determination of atropine.

A fast and sensitive method for the determination of atropine, an alkaloid closely related to cocaine, is proposed. The principles of on-line ion-pair formation of alkaloid-metal complexes and liquid-liquid extraction are applied to the chemiluminescence determination of atropine. On mixing with a reversed micellar medium of cetyltrimethylammonium chloride in dichloromethane-cyclohexane (1:1 v/v)-water (0.3 M Na2CO3) containing luminol, the ion-pair complex of tetrachloroaurate(III) with atropinium produced an analytical chemiluminescence signal when it entered the reversed micellar water pool. Using the reverse-flow injection and chemical conditions optimized for atropine in aqueous samples, a detection limit of 1 ng/mL was achieved and a linear calibration graph was obtained with a wide dynamic range from 10 ng/mL to 100 micrograms/mL. The proposed method is simple and provides a good precision with a relative standard deviation (n = 6) of ca. 3% at the atropine concentration of 100 ng/mL. After a preliminary study involving the potential interference from species of organic, inorganic, and metallic nature, the method was applied to the determination of atropine in artificial urine samples and of atropine and scopolamine in pharmaceutical formulations.

Atropine↗

Rearrangement of L-2-hydroxyglutarate to L-threo-3-methylmalate catalyzed by adenosylcobalamin-dependent glutamate mutase.

Adenosylcobalamin-dependent enzymes catalyze a variety of chemically difficult isomerizations in which a nonacidic hydrogen on one carbon is interchanged with an electron-withdrawing group on an adjacent carbon. We describe a new isomerization, that of L-2-hydroxyglutarate to L-threo-3-methylmalate, involving the migration of the carbinol carbon. This reaction is catalyzed by glutamate mutase, but k(cat) = 0.05 s(-)(1) is much lower than that for the natural substrate, L-glutamate (k(cat) = 5.6 s(-)(1)). EPR spectroscopy confirms that the major organic radical that accumulates on the enzyme is the C-4 radical of L-2-hydroxyglutarate. Pre-steady-state kinetic measurements revealed that L-2-hydroxyglutarate-induced homolysis of AdoCbl occurs very rapidly, with a rate constant approaching those measured previously with glutamate and methylaspartate as substrates. These observations are consistent with the rearrangement of the 2-hydroxyglutaryl radical being the rate-determining step in the reaction. The slow rearrangement of the 2-hydroxyglutaryl radical can be attributed to the poor stabilization by the hydroxyl group of the migrating glycolyl moiety of the radical transiently formed on the migrating carbon. In contrast, with the normal substrate the migrating carbon atom bears a nitrogen substituent that better stabilizes the analogous glycyl moiety. These studies point to the importance of the functional groups attached to the migrating carbon in facilitating the carbon skeleton rearrangement.

Animals↗

Oxidation of yeast iso-1 ferrocytochrome c by yeast cytochrome c peroxidase compounds I and II. Dependence upon ionic strength.

The reduction of cytochrome c peroxidase compound I by excess yeast iso-1 ferrocytochrome c is biphasic. Two pseudo-first-order rate constants can be measured by stopped-flow techniques. The fastest rate process is the reduction of cytochrome c peroxidase compound I to compound II, and the slower process is the reduction of II to the native enzyme. The yeast iso-1 ferrocytochrome c concentration dependence of the reduction of cytochrome c peroxidase compound I to compound II is consistent with a mechanism involving two binding sites for cytochrome c on cytochrome c peroxidase. Electron transfer from cytochrome c bound at the high-affinity binding site to the Fe(IV) site in cytochrome c peroxidase compound I is dependent upon ionic strength, increasing from 15 +/- 6 to 2000 +/- 100 s-1 over the ionic strength range 0.01-0.20 M. The reduction rate of the Fe(IV) site in the 2:1 yeast iso-1 ferrocytochrome c/cytochrome c peroxidase compound I complex is essentially independent of ionic strength with a value of 3800 +/- 300 s-1. The Fe(IV) site in cytochrome c peroxidase compound I is preferentially reduced by yeast ferrocytochrome c between 0.01 and 0.20 M ionic strength while the Trp-191 radical is preferentially reduced above 0.30 M ionic strength. The association rate constant for the binding of yeast iso-1 ferrocytochrome c to cytochrome c peroxidase compound I can be evaluated and varies from a remarkable 1 x 10(10) M-1 s-1 at 0.01 M ionic strength to 1.2 x 10(5) M-1 s-1 at 1.0 M ionic strength. Between 0.01 and 0.20 M ionic strength, the reduction of cytochrome c peroxidase compound II to the native enzyme is anomalous. The reaction is independent of the cytochrome c concentration and directly proportional to the initial cytochrome c peroxidase compound I concentration.

Binding Sites↗

Electron transfer reactions between aromatic amine dehydrogenase and azurin.

Binding and electron transfer reactions between the tryptophan tryptophylquinone (TTQ) enzyme, aromatic amine dehydrogenase (AADH), and the type I copper protein azurin have been characterized. In steady-state kinetic assays using azurin as an electron acceptor, it was observed that the apparent Km for azurin decreased with increasing ionic strength. These results are the opposite of what was observed for the reaction between the TTQ enzyme methylamine dehydrogenase (MADH) and amicyanin, despite the fact that in both cases the pairs of redox proteins are each acidic proteins. It was further demonstrated that azurin does not function as an effective electron acceptor for MADH, and that amicyanin does not function as an effective electron acceptor for AADH. Thus, while the two TTQ enzymes each use type I copper proteins as physiologic electron acceptors, there is a strong specificity for which copper protein serves as a redox partner. The kinetic parameters for the electron transfer reactions from reduced AADH to oxidized azurin were determined by stopped-flow spectroscopy. Different results were obtained depending upon whether AADH was reduced chemically with dithionite or with the substrate tyramine. The values for the limiting first-order apparent electron transfer rate constant (kET) at 30 degrees C were 4 and 102 s-1, respectively. Kinetically determined values of Kd also differed by a factor of 2.4. These data suggest that the incorporation of the substrate-derived amino group into the reduced TTQ of AADH significantly increases the apparent kET. The interaction between AADH and azurin was also quantitated using an ultrafiltration binding assay. This yielded a Kd of 300 microM for the AADH--azurin complex.(ABSTRACT TRUNCATED AT 250 WORDS)

Alcaligenes↗

The ferrous heme of soluble guanylate cyclase: formation of hexacoordinate complexes with carbon monoxide and nitrosomethane.

The soluble form of guanylate cyclase (sGC) is the only definitive receptor for the signaling agent nitric oxide (.NO). The enzyme is a homologous heterodimer in which each subunit binds 1 equiv of 5-coordinate high-spin heme. .NO increases the Vmax of sGC up to 400-fold, probably by binding directly to the heme. Carbon monoxide (CO) forms a 6-coordinate complex with the heme and weakly activates the enzyme. Using stopped-flow spectrophotometry, the on-rate and off-rate for the binding of CO to the heme have been determined to be (3.58 +/- 0.15) x 10(4) M-1 s-1 and 3.5 +/- 0.5 s-1, respectively, at 10 degrees C. The equilibrium dissociation constant (Kd) has been independently determined to be 97 +/- 9 microM. Comparison of this Kd with that calculated from the rate constants indicates that the binding of CO to sGC is a simple one-step process, in which the off-rate of CO from the hexacoordinate complex is much faster than typically found in hemoproteins. The Kd of CO for activating the enzyme was also determined and compared to that for binding to the heme. Nitrosomethane forms irreversible complexes with typical ferrous hemoproteins but was observed to bind reversibly to the heme in sGC, with an off-rate > or = (7.6 +/- 0.2) x 10(-3) s-1. In general, the ferrous heme in sGC has a low affinity for ligands that form 6-coordinate complexes due primarily to fast ligand off-rates.

Animals↗

Spectroscopic, calorimetric, and kinetic demonstration of conformational adaptation in peptide-antibody recognition.

Little is known about the extent to which protein flexibility contributes to antigen-antibody recognition and cross-reactivity. Using short coil peptides (leucine zippers) as model antigens, we demonstrate that a monoclonal antibody can force a noncognate peptide into a conformation that is similar to the conformation of the cognate peptide against which the monoclonal antibody is directed. Monoclonal antibodies 29AB and 13AD were raised against the 29-residue peptide LZ (Ac-EYEALEKKLAALEAKLQALEKKLEALEHG-amide) that forms a very stable coiled coil. The two antibodies cross-reacted strongly with the random coil analogue LZ(7P14P) that contains Lys-->Pro and Ala-->Pro substitutions in positions 7 and 14, respectively. The antibody-bound peptide LZ(7P14P) adopted an altered conformation that possibly was coiled coil-like, as shown by CD difference spectroscopy and fluorescence quenching experiments on coumarin-labeled peptides. Isothermal titration calorimetry revealed that the cross-reaction of antibodies 13AD and 29AB with the random coil peptide LZ(7P14P) exhibited a large unfavorable entropy. This, however, was strongly compensated by a more favorable enthalpy, resulting in only a small difference between the association constants for peptide LZ and LZ(7P14P), respectively. To investigate the opposite type of cross-reaction, monoclonal antibody 42PF was raised against the random coil peptide LZ(7P14P). 42PF cross-reacted with coiled coil peptide LZ by forcing it to dissociate into single chains. Enthalpy/entropy compensation again enabled the cross-reaction, which now was entropically favored and enthalpically disfavored. The rate of reaction of antibody 42PF with peptide LZ was controlled by the rate of dissociation of LZ into single chains. This observation, as well as the generally much slower reaction rate with the noncognate peptides, indicated that the cross-reactivity occurred because the antibody selected the conformer of the antigen that binds the strongest, a mechanism we call "induced fit by conformational selection."

Amino Acid Sequence↗