Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ARTIFICIAL LIMBS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93Linked to original sources

Perinatal limb ischemia: orthopaedic implications.

Fifteen patients (16 ischemic limbs) who ultimately required amputation for perinatal limb ischemia were treated at The Children's Hospital of Philadelphia and the Shriners Hospital for Crippled Children in Philadelphia between 1980 and 1993. The average birth weight of these patients was 1,870 g, and the average gestational age was 30.8 weeks. Ischemic events occurred at an average postnatal age of 5.4 weeks. The causes of the ischemia included (a) arterial thrombosis as a complication of arterial catheterization (eight patients), (b) thromboembolism resulting from a hypercoagulable state (five patients), (c) intravenous infiltrate (one patient), and (d) in utero arterial thrombosis (one patient). Amputation was required at an average postnatal age of 8.5 weeks. The final patient, with concurrent ischemia involving the right hand and left leg, had complete resolution of the ischemic hand with fibrinolytic therapy alone and required only an amputation of the lower extremity. Eleven of the 15 patients were available for follow-up (two dead, two lost to follow-up), at an average of 4.5 years. Nine of these 11 patients (six lower and three upper extremities) are functioning well in prostheses. The two remaining patients are infants who will be fitted for lower-extremity prostheses when they begin to attempt to walk.

Amputation, Surgical↗

Bilateral lower limb amputations as a result of landmine injuries.

Landmine explosions cause most of the war injuries in the battlefield. Amputations resulting from severe injuries reveal serious problems despite the improvements in surgery. Bilateral lower limb amputations have more impact than unilateral on social life. Some 29 cases with lower limb amputations due to landmine injuries were treated in the Department of Orthopaedics and Traumatology, Gülhane Military Medical Academy between January 1992 and December 1996. Amputation levels were as follows: 1 case had hip disarticulation and a trans-femoral amputation, 6 had bilateral trans-femoral amputations, 6 had trans-femoral and trans-tibial amputations, 12 had bilateral trans-tibial amputations, 1 had trans-femoral and Chopart amputations and the remaining 3 cases had trans-tibial and Chopart amputations. The initial treatment was done for all cases in the first 6-8 hours after injury at the field hospitals. Aggressive debridement, excision and primary closure were performed. None of the stumps required reamputations and/or revision. No case had gas gangrene or tetanus. Postoperative, pre-prosthetic training programme which ranged between 30-120 days with an average 48 days; and prosthesis fitting and adequate post-prosthetic training programme which ranged 32-126 (average 94) days was applied. All the cases were followed-up with a mean of 38.5 months (14-72 months). Nine (9) cases (31%) returned to their previous occupation, while 20 (69%) cases had to change their jobs.

Adult↗

Extracortical bridging callus after limb salvage surgery about the knee.

The increasing survival of children treated for osteosarcoma has led to an increase in limb sparing surgery. Little published information is available about the postoperative imaging appearance of this technique. Thus, information gleaned from medical records and imaging reviews was correlated with clinical outcome of 19 consecutive children (median age at diagnosis, 12.3 years) treated for distal femoral osteosarcoma with a cemented rotating hinged knee endoprosthesis with porous coated collar. An extracortical bridging bony callus was identified in 16 patients who were followed up after surgery for a median of 2.8 years (range, 1.4-6 years). Extracortical bridging bony callus formation was circumferential in eight and preferentially posterior in nine, and ranged from 0.5 to 0.7 cm in thickness; 14 patients had lucent lines subjacent to the bridging bone. Thirteen patients had good functional use of the surgically treated leg. Five patients had progressive metastatic disease develop. One patient had local disease recurrence 8 months after surgery. Extracortical bridging bone was not identified in three patients, two of whom had infection develop 7 months and 17 months after surgery; both infections required amputation. Extracortical bridging bone preferentially develops posteriorly, along the compression side of the femur, often is associated with subjacent lucency, and seems to reflect increased prosthetic stability.

Adolescent↗

Evaluation of the validity of the prosthetic upper extremity functional index for children.

OBJECTIVE: To evaluate the validity of the Prosthetic Upper Extremity Functional Index (PUFI), a parent- and older child-report measure that evaluates the extent of Prosthetic limb use, ease of task performance with and without the prosthesis, and its usefulness. DESIGN: Evaluation of discriminant validity (the PUFI's ability to detect differences between children), construct validity (between the parent-report PUFI and University of New Brunswick Test of Prosthetic Function [UNB Test]), and criterion validity (comparison of parent-report PUFI responses with an assessor's scores of a child's performance of PUFI activities). SETTING: Four pediatric amputee clinics. PARTICIPANTS: Thirty-eight children, ages 3 to 18 years, with unilateral upper-extremity amputation and a prosthesis. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: The PUFI and the UNB Test. RESULTS: The PUFI differentiated between children in high and low UNB Test score categories, and between younger and older children's functional abilities. The extent of correlation between PUFI ratings and UNB skill of performance scores was moderate for "ease of performance" and "usefulness of prosthesis" categories (r>.47, P<.05). The level of agreement between parent report and observational assessment of PUFI skills was acceptable (weighted kappa range,.44-.65). CONCLUSIONS: The PUFI showed acceptable validity and showed promise in identifying prosthetic skill and use in children of different ages and abilities.

Activities of Daily Living↗

Lower limb prosthesis utilisation by elderly amputees.

The goal of prosthetic rehabilitation is to compensate for the loss of a limb by amputation by, in the case of a lower limb, encouraging walking, and to achieve the same level of autonomy as prior to the amputation. However, because of difficulties walking, elderly amputees may use their prosthesis to a greater or lesser degree or simply stop using it during the rehabilitation period. The objective of this research was to study factors such as physical and mental health, rehabilitation, physical independence and satisfaction with the prosthesis to understand why amputees use their prosthesis or not. The sample was composed of 65 unilateral vascular amputees 60 years old or over living at home. The information was collected from medical records, by telephone interview and by mail questionnaire. Prosthesis use was measured by a questionnaire on amputee activities developed by Day (1981). Eighty-one per cent (81%) of the subjects wore their prosthesis every day and 89% of this group wore it 6 hours or more per day. Less use of the prosthesis was significantly related to age, female gender, possession of a wheelchair, level of physical disability, cognitive impairment, poorer self-perceived health and the amputee's dissatisfaction. A multiple regression analysis showed that satisfaction, not possessing a wheelchair and cognitive integrity explained 46% of the variance in prosthesis use.

Age Distribution↗

A robust design procedure for improvement of quality of lower-limb prosthesis.

Lower-limb prostheses are used to restore amputee's walking. Monolimb is one of the designs referring to socket and the shank being molded into one piece of thermoplastic material. Appropriate shank flexibility of a monolimb can improve gait of an amputee. However, during the fabrication, the variations of design variables are inevitably produced which may lead the unexpected shank deflection and directly influence on gait efficiency of an amputee. This paper presents a robust design procedure for improvement of quality of the monolimb by simultaneously minimizing performance variations caused by variations in design variables and bringing the mean value of performance on target. The robust design procedure embodies the integration of response surface methodology with genetic algorithms. Response surface models are developed for the responses of monolimb as functions of design variables over the region of interest and genetic algorithms are employed to find the robust solution. A robust design of monolimb is performed for an amputee subject and the results show that the robust design can design a "robust" monolimb which provides specified performance targets that are minimally sensitive to the variations of design variables. This indicates that robust design may have the potential application in improving the quality of the prescribed prosthesis.

Algorithms↗

The efficacy of physiological cost index (PCI) measurement of a subject walking with an Intelligent Prosthesis.

The Intelligent Prosthesis may enable lower limb amputees to walk faster than with conventionally damped prostheses and as a result the physical burden involved in walking could be expected to be considerably higher. The aim of this study was to investigate whether or not physiological cost index (PCI) is applicable as an indicator for monitoring the amount of exercise load involved in walking with an Intelligent Prosthesis. The method used a treadmill and monitored gas exchange, ventilation and heart rate (HR) in 6 unilateral trans-femoral amputees, ages were between 17 and 34 with an average age of 23.1. The exercise protocol was as follows: for each person speeds at 0.8 times the subject's free level walking speed, 1.0 times, 1.2 times, 1.4 times and for some 1.6 times were applied. In each case the index of correlation between PCI and oxygen uptake in response to walking speed was calculated. A significant correlation was observed between PCI and oxygen uptake in each case, which indicated a close relationship between cardiopulmonary factor and energy consumption while walking. These results suggest that PCI is of use as an indicator for ascertaining the amount of exercise load in walking with an Intelligent Prosthesis.

Adolescent↗

Use of lower limb prosthesis among elderly amputees.

Forty-seven elderly patients (21 males and 26 females) with lower limb amputation, and with prostheses fitted were studied. Their ages ranged from 65 years to 91 years old, with an average of 75.4 years. The three most common contributory causes for amputation were diabetes mellitus, vascular occlusion and carcinoma of the skin. Among the lower limb amputations, below knee amputation was the most common (93.6%). About 30% of the patients developed complications from prostheses, the 3 most common in order of frequency were stump pain, pressure ulcers and stump infection. Male patients tended to do better with prostheses than female patients. More male patients wanted prostheses for mobility, while most female patients cited cosmesis as the reason for wanting a prosthetic leg. More male patients used the prostheses more frequently and this was associated with a higher level of function in terms of self care and mobility. Reasons for non-usage of prosthesis were poor-fitting sockets, floppy stump, stump ulcers and infection. Carers of male amputees tended to cope better than those caring for female amputees. Both the present age of patient, and the age at amputation were found not to be a factor in deciding the frequency of usage of prosthesis, and the outcome of success in rehabilitation of the amputee. Psychological factors played an important role in the outcome of rehabilitation. Eighty-five percent of patients who functioned at a lower level despite a relative lack of serious medical condition cited psychological reasons for their poor performance, among which were age and the 'expected' loss of mobility with amputation.

Aged↗

Testing of elastomeric liners used in limb prosthetics: classification of 15 products by mechanical performance.

The mechanical properties of 15 elastomeric liner products used in limb prosthetics were evaluated under compressive, frictional, shear, and tensile loading conditions. All testing was conducted at load levels comparable to interface stress measurements reported on transtibial amputee subjects. For each test configuration, materials were classified into four groups based on the shapes of their response curves. For the 15 liners tested, there were 10 unique classification sets, indicating a wide range of unique materials. In general, silicone gel liners classified within the same groups thus were quite similar to each other. They were of lower compressive, shear, and tensile stiffness than the silicone elastomer products, consistent with their lightly cross-linked, high-fluid content structures. Silicone elastomer products better spanned the response groups than the gel liners, demonstrating a wide range of compressive, shear, and tensile stiffness values. Against a skin-like material, a urethane liner had the highest coefficient of friction of any liner tested, although coefficients of friction values for most of the materials were higher than interface shear:pressure ratios measured on amputee subjects using Pelite liners. The elastomeric liner material property data and response groupings provided here can potentially be useful to prosthetic fitting by providing quantitative information on similarities and differences among products.

Artificial Limbs↗

Polyurethane gel liner usage in the Oxford Prosthetic Service.

The objective was to investigate which lower limb amputees are using Alpha polyurethane gel liners and the effects of these on comfort and suspension of their prosthesis. A retrospective study was carried out of case records of all patients issued with Alpha cushion and locking liners between 1997 and the end of January 1999. The type of liner used was compared with age, sex, level and cause of amputation, time since amputation, comfort and suspension. Modified Stanmore/Harold-Wood mobility grades; duration of use and number of liners issued per patient were recorded. Sixteen (16) patients were identified who had been prescribed Alpha cushion liners. Improved comfort was reported by all. Forty (40) patients were identified who had been prescribed Alpha locking liners. Twenty (20) of these reported improved comfort and 10 improved suspension. The average time since amputation was 18.5 years for those using cushion liners and 14.1 years for locking liner users. Fifty-two (52) of all 56 patients using Alpha cushion and locking liners had mobility grades of 4 or more. Trauma was the most common cause of amputation. This group is a relatively mobile group of amputees. All those using cushion liners reported improved comfort. Some of the locking liner users reported improved comfort and suspension but this was not universally the case.

Adolescent↗

Early post-surgical prosthetic fitting with a pre-fabricated plastic limb.

Early prosthetic fitting and independent ambulation are major goals in the rehabilitation of amputees with early walking being extremely valuable in the physical and psychosocial rehabilitation of the amputee. With early resumption of weight bearing and ambulation, deterioration of postural reflexes can be prevented and the residual limb (stump) can be shaped for definitive prosthetic fitting. A new temporary prosthesis was evaluated in its use on new below-knee amputees. The prosthesis is a plastic, hollow form which fits over the conventional rigid, plaster postoperative dressing. It comes in one size and is cut to fit the patient. The prosthesis is readily available, needs little training for its application, can be re-used, and is inexpensive. Twenty-two consecutive patients treated at Hines Veteran's Administration Hospital and Loyola University Medical Center underwent below-knee amputations. All were determined to be potential walkers. The average age at surgery was 61 years with a range of 17 to 74 years. Amputation was performed for trauma in two patients and gangrene in the other 20. All wounds were dressed with conventional rigid, plaster dressings with cast changes five days postoperatively. The prefabricated temporary prosthesis was applied at the second cast application at an average of 8.1 days postoperatively with permanent prosthetic fitting at 7.7 weeks. There were no complications related to the use of the plastic temporary prosthesis. The use of a new plastic temporary prosthesis has been found to be advantageous in the early rehabilitation of below-knee amputees.

Adolescent↗

Prognostic factors in prosthetic rehabilitation of bilateral dysvascular above-knee amputee: is the stump condition an influencing factor?

AIM: The aim of this study was to evaluate the prognostic factors for rehabilitation outcome in bilateral dysvascular lower limb amputees, specifically to ascertain how the stump condition can influence the mobility outcome. METHODS: A retrospective study of 30 selected bilateral above-knee amputees for vascular disease was carried out. Barthel Index (BI) was given and stump condition was assessed at admission and at discharge. Influence of age, comorbidities and stump condition on effectiveness of BI was evaluated. Locomotor Capability Index (LCI) was performed at discharge. Influence of stump problems (pain, flexion, pain with flexion) on LCI was evaluated. RESULTS: At discharge, 25 patients were able to ambulate. Age and pathological conditions of stumps correlated negatively with BI effectiveness. LCI values were higher for patients with ideal stumps and lower for patients with combined stump pain and flexion deformities. Post hoc analysis showed that the principal factor negatively influencing the LCI score was the presence of stump flexion deformities. CONCLUSIONS: In our homogeneous group of bilateral amputees, age reduced the possibility of improving the level of autonomy. Good stump quality is one of the major determinants of mobility outcome. Efforts should be made to minimize stump complications. In particular, incorrect positioning of the stump, which is responsible for hip flexor retraction, should be avoided after surgery.

Activities of Daily Living↗

Lower limb proximal amputation for a tumour: a retrospective study of 12 patients.

OBJECTIVE: To analyse survival, prosthetic fitting and functional status after trans-femoral amputation or hip disarticulation for a primitive tumour. METHODS: Retrospective study of all patients admitted since 1985. RESULTS: Mean age at amputation was 55. Causes of amputation were osteosarcoma in 50%. Eight (8) patients had initial conservative surgery. Local recurrence was never observed. Nine (9) developed metastasis and required further hospitalisation. Fifty percent (50%) of patients died. Inpatient rehabilitation started 14 days after amputation (7-27), and was of a mean duration of 32 days. Prosthetic fitting was performed 13 days after admission (7 days when a liner was used). Further improvement of the prosthesis was performed in 10 patients. Among the patients who died, 5 had gone home, 4 were wearing their prosthesis all day long and 2 walked indoors with no additional support at discharge. Three (3) patients lived less than 2 months at home. Among the patients who did survive, all went home, 5 were wearing their prosthesis all day long and 2 walked indoors without aid at discharge. Two (2) patients practised sport and 4 drove. All the patients who were active have gone back to work. CONCLUSIONS: Gain due to prosthesis provision is undebatable. Good functional results can be obtained with adapted materials. Initial problems due to the synchronisation of treatments are resolved with multidisciplinary care. All patients should have a rapid and short hospitalisation in a rehabilitation unit and receive a first, simple prosthesis that can be further adapted.

Adult↗

The CAT-CAM socket and quadrilateral socket: a comparison of energy cost during ambulation.

Twenty unilateral trans-femoral amputees fitted with either the Contoured Adducted Trochanteric-Controlled Alignment Method (CAT-CAM) socket (n = 10) or the quadrilateral (QUAD) socket (n = 10), and a "non-amputee" control group (n = 10) participated in the study. Subjects meeting the following criteria were studied: healthy males between the ages of 18 and 55 years, amputation due to non-vascular pathology, an unaffected sound limb, at least six months use of the test prosthesis, and a minimal stump length of 15 cm. Subjects ambulated in two randomized trials separated by 20 minutes of rest at 2 assigned speeds: a pace reflecting normal walking speed (97 m/min = 2.5 mph) or a slower speed (48.5 m/min = 1.25 mph). Heart rate (HR) and Oxygen uptake (VO2) measured during steady state walking were analyzed via two-way ANOVA. Differences among means were further analyzed using Tukey post hoc and simple effects tests. Significant differences were observed between the control group and CAT-CAM subjects with respect to VO2 (p < 0.05) and HR (p < 0.01) at the slower speed. The control group and subjects using the QUAD socket also differed with respect to VO2 (p < 0.01) and HR (p < 0.01) at the slower pace. Faster pace required more energy expenditure (p < 0.01) and produced higher HR (p < 0.01) than slower speeds. At faster pace, a significantly higher energy expenditure in the QUAD than the CAT-CAM group was observed (p < 0.01). It is concluded that ambulating at normal pace using the CAT-CAM socket design uses less energy than when using a QUAD socket design.

Adolescent↗

Validation of spiral CT and optical surface scanning for lower limb stump volumetry.

Spiral X-ray Computed Tomography (SXCT), Optical Surface Scanning (OSS), and hydrostatic weighing methods were used to measure stump volume of trans-tibial amputees. The precision and accuracy of these methods were assessed in a validation study. A repeated measures analysis of variance statistical design was employed that required each participant to be measured (scanned) twice at each of two separate measurement sessions. For OSS and SXCT, each scan was segmented twice to determine intra-observer error. Plaster cast replicas of subject stumps were formed by certified prosthetists to serve as a reference standard. Accuracy (bias) of SXCT and OSS was determined by comparison to volumetry by hydrostatic weighing. Ten trans-tibial amputees were recruited for this study and nine completed both sessions. Plaster replica measurement precision error relative to the mean was found to be less than 1% for all modalities. The precision was slightly inferior on subjects, 1.1% and 2.2% error for hydrostatic weighting and OSS respectively, due to patient instability during measurement, but was better with SXCT where the subjects' stumps were stabilized during scan acquisition. The OSS and SXCT methods offer advantages over hydrostatic weighing and other volumetry methods since the volume data are represented digitally and can be analyzed in multiple ways. SXCT enables study of the stump and its internal tissues with the prosthesis in place. It was found that SXCT is comparable to hydrostatic weighing in both precision and accuracy. While OSS had a high precision and reproducibility, it was found to have an associated bias.

Adult↗

Dynamic balance training during standing in people with trans-tibial amputation: a pilot study.

Falls and fear of falling are significant problems arising from impaired balancing abilities that affect people with lower limb amputation during unassisted transfer manoeuvres and ambulation. It is important to develop and evaluate efficient therapeutic interventions aimed at improving balancing and coordination skills. A group of 14 persons after trans-tibial amputation, fitted with trans-tibial prostheses, were included in a balance-training programme, consisting of approximately 20 minutes of balance training per day for five consecutive days on BalanceReTrainer--a novel balance-training, fall-safe mechanical apparatus. Before and after the training period three outcome measures were taken: duration of standing only on the prosthetic leg, timed up and go test and 10m walk. Each measurement was repeated five times and the mean value was used in the subsequent calculation of mean values and standard deviations for the group. Before training the group was able to stand on the prosthetic leg for 2.98 +/- 2.75s, they needed 6.15 +/- 1.9s for accomplishing timed up and go test and they needed 5.51 +/- 1.5s to cover the distance of 10m. After the treatment period the values were 4.3 + 4.5s, 5.4 +/- 1.5s and 4.5 +/- 0.9s, respectively. The results indicate improved performance in all three measured tasks, thereby indicating that the applied treatment programme improves balancing and ambulation abilities in people after trans-tibial amputation.

Accidental Falls↗

Effects of alignment changes on stance phase pressures and shear stresses on transtibial amputees: measurements from 13 transducer sites.

Interface pressures and shear stresses were measured at 13 sites on two unilateral below-knee amputee subjects ambulating with lower-limb patellar-tendon-bearing prostheses. Interface stresses at the time of the first peak in the shank axial force-time curve were investigated at different socket-shank alignment settings. Stress magnitudes ranged from 1.2 to 214.7 kPa for pressure and 0.4 to 79.6 kPa for resultant shear stress, and changes in stress due to misalignment ranged from 1.3 to 80.7 kPa for pressure and from 0.2 to 38.0 kPa for resultant shear stress. For both subjects interface stress changes were much greater in the anterior socket region than in the lateral or posterior regions. Thus, alignment changes had a localized effect on interface stresses. Plots of alignment versus pressure or resultant shear stress were nonlinear for both subjects, in a number of cases maximizing or minimizing at the nominal alignment, indicating complex interface stress-alignment relationships. Variation (standard deviation/mean) was not significantly different for nominal versus misaligned steps, indicating that the subjects adapted well to the alignment changes. Session to session differences in interface stresses were typically larger than interface stress differences induced by alignment modifications. Thus, while these subjects compensated well for alignment changes to maintain consistent interface stresses within a session, they did not do so for different sessions conducted weeks apart.

Adult↗

[Prosthesis replacement of proximal humerus after resection of malignant tumor].

OBJECTIVE: To study the operative effect and complication of the prosthesis replacement of the proximal humerus with malignant tumor. METHODS: From October 1998 to August 2003, the prosthesis replacement was performed to treat the proximal femur with malignant tumor in 4 patients, including 2 patients with osteosarcoma (Enneking staging, I A) and 2 patients with giant cell tumor of the bone (II A, II B). By the International Society of Limb Salvage (ISOLS) criterion, the 2 cases of osteosarcoma were preoperatively scored as 4 and 5 points, and 2 cases of giant cell tumor of the bone were scored as 9 and 11 points. The patients' psychological conditions as well as their limb pain, shape, locality, activity, and function were also observed. RESULTS: The follow-up for 24-58 months (mean, 44 months) showed that there was no local recurrence or infection in all the patients except one patient who had the loosening of the screws for the fixation 17 months after operation and had no treatment. After operation, all the patients had a better postoperative extention angle from 22 degrees to 41 degrees (mean, 25 degrees), bending angle from 29 degrees to 80 degrees (mean, 35 degrees), abduction angle from 5 degrees to 28 degrees, and circumgyrate angle from 15 degrees to 22 degrees in their shoulder joints. However, the shoulder joint function was still unstable to some extent and the joints had a decreased strength. By the criterion formulated by the ISOLS, the postoperative score for assessing the 2 patients with osteosarcoma was increased by 16 points when compared with the preoperative score; the score for the 2 patients with giant cell tumor of the bone was increased by 9.5 points. CONCLUSION: The prosthesis replacement to treat the malignant tumor of the proximal humerus is the good method of choice and has a good therapeutic result; however, there are more complications and so the method should be cautiously employed in the clinical practice.

Adult↗