Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ACRYLIC RESINS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93Linked to original sources

Temporary restorations: advantages and disadvantages.

The reaction of tissue to temporary restorations was studied in four young dogs and four young monkeys. A total of 56 cavities were prepared and filled with gutta percha, self-curing acrylic resin, or zinc oxide and eugenol cement. Attempts were made to finish the preparations at the deepest point of the existing clinical pocket, which invariably was found to coincide with the cemento-enamel junction. All the animals had the teeth on the left side brushed every day. The observation periods varied between 13 and 283 days. Immediately before the animals were killed by an overdose of Nembutal, the presence or absence of gingivitis was recorded. A series of sections were cut in the area of the cavity, as well as just outside it. The following observations were made: Examination of the sections from outside the cavities verified that the preparations had been made in pockets with soft walls made up of the junctional epithelium. The cavities ended shortly above the cemento-enamel junction (Figs. 3, 4, 6, and 8) or below it (Figs. 1, 2, 5, 7, and 9 to 11). The adaptation of the fillings was never perfect in all parts of the cavity at the same time. The pocket epithelium was regenerated within 13 days. Plaque formation first started in the open spaces between the preparation and the fillings. Subsequently, the plaque spread over the surfaces of the fillings and eventually over the tooth surface below them. The fillings invariably induced submarginal gingivitis, even in the absence of plaque. Presence of plaque exacerbated the inflammatory reaction, but the loss of attachment was limited to less than 0.2 mm as long as the plaque was confined to the fillings. Significant loss of attachment was always associated with apical growth of the subgingival plaque. The submarginal gingivitis was not manifested clinically if the fillings were brushed daily, because vigorous tooth brushing had an effect as far as 0.7 mm below the gingival margin.

Acrylic Resins↗

Retention of cast posts cemented with zinc phosphate cement using different cementing techniques.

PURPOSE: This study compares the effect of different cementation techniques on the retention of cast posts and cores. MATERIALS AND METHODS: Twenty-four extracted single rooted human teeth were used in this study. After routine preparation of the root canals, the canal space was enlarged with reamers. Direct post patterns were made with acrylic resin. Castings were fabricated using Ni-Cr-Mb alloy. Zinc phosphate cement was used as a luting agent using 4 different methods of cement introduction to the root canal space. This created 4 treatment groups consisting of 6 teeth in each group. In Group A, the cement was applied over the posts only. For the specimens in Group B, the cement was introduced into the root canals with a spiral filler and applied over the posts. In Group C, cement was injected into the root canals and then applied over the posts. Finally, for the specimens in Group D, cement was injected into the root canals and a spiral was used to spread it into the root canals, and cement was also applied over the posts. After cementation, teeth were stored in saline solution. The tensile retentive force of cast posts was evaluated using the Instron testing machine (Instron, Canton, MA). RESULTS: The retention obtained by the 4 techniques differed significantly (p <.05). The highest tensile force to post dislodgment was observed in Group D, and the least was in Group A. Analysis of variance test revealed a highly significant difference between groups (p <.0001). According to the Fisher exact test, there was a significant increase in retention from Group A to Group D (p <.05). CONCLUSIONS: Under the conditions of this study, the injection of cement into a root canal space followed by the use of a spiral resulted in the highest level of post retention. Retention was reduced when cement was placed using a Lentulo spiral alone (Kerr/Sybron Corp, Romulus, MI), a Jiffy tube (Teledyne Water Pik, Allegheny Teledyne Co, Fort Collins, CO) alone, or by application to the post only. J Prosthodont 2001;10:37-41.

Acrylic Resins↗

Electromyographic evaluation of the adductor pollicis muscle of elderly patients carriers of removable partial prosthesis when using acrylic devices adapted to the handle of toothbrush.

The aim of this study was to evaluate the muscular activity of the adductor pollicis muscle, by electromyography, when using a device made of acrylic resin adapted to the handle of toothbrush. 10 patients of both sexes from the Clinic of Removable Partial Dentures of the Dental School--USP, with a mean age of 65 years, were selected. Electromyographic records were obtained with patients in clinical conditions of Initial Rest and under conditions of claw apprehension and dental brushing. The mean results obtained, in mV, were: sat men: 2.97 for rest (R); 11.55 for free closure (FC); 35.80 for strained closure (SC); 29.30 for simulated brushing (SB); 55.00 for brushing (B); 26.87 for simulated brushing with the device (SBA); 69.70 for brushing with the device (BA); 3.72 for post exercise rest (PR). Standing: 2.27 for rest (R); 13.92 for free closure (FC); 45.85 for strained closure (SC); 28.40 for simulated brushing (SB); 72.07 for brushing with the device (BA); 1.42 for postexercise rest (PR). Sat women: 9.78 for rest (R); 22.71 for free closure (FC); 41.48 for strained closure (SC); 26.45 for simulated brushing (SB); 52.78 for brushing (B); 17.00 for simulated brushing with the adapter (SBA); 42.38 for brushing with the adapter (BA); 14.40 for postexercise rest (PR). Standing: 5.26 for rest (R); 17.81 for free closure (FC); 46.55 for strained closure (SC); 40.61 for simulated brushing (SB); 61.71 for brushing (B); 26.08 for simulated brushing with the adapter (SBA); 54.06 for brushing with the adapter (BA); 3.46 for postexercise rest (PR). The adductor pollicis muscle showed a higher electromyographic activity, considered statistically similar to each other, in 3 clinical conditions analyzed: brushing (B), brushing with the adapter (BA) and strained closure (SC). The adductor pollicis muscle showed lower electromyographic activity, considered statistically similar, in 5 clinical conditions analyzed: simulated brushing (SB), simulated brushing with the adapter (SBA), free closure (FC), rest (R) and postexercise rest (PR).

Acrylic Resins↗

An oral formulation of nicotine for release and absorption in the colon: its development and pharmacokinetics.

AIMS: Ulcerative colitis is predominantly a disease of nonsmokers and transdermal nicotine has therapeutic value in active disease; however side-effects are troublesome. The aim of this study was to develop an oral formulation of nicotine which would be slowly released in the colon over 6 h, and to examine its pharmacokinetic profile in 12 healthy volunteers, with measurements of serum nicotine and cotinine, its principal metabolite. METHODS: Nicotine was combined with a polyacrylic carbomer, Carbopol 974P which was incorporated into 13 different vehicles and their release profiles examined in vitro. The polyglycolized glyceride, Gelucire 50/13, was chosen for subsequent kinetic studies because it consistently produced a suitable release pattern which was linear. Capsules containing 3 mg nicotine, combined with carbomer in Gelucire 50/13, were coated with an acrylic resin Eudragit L; this ensured the capsule would remain intact until the ileum. On 2 separate days, 6 and 15 mg nicotine, contained in 2 and 5 capsules, respectively, were administered to 12 subjects, all nonsmokers, mean age 28 years. Serial blood measurements were taken for 36 h, serum nicotine and cotinine concentrations were measured by gas liquid chromatography. RESULTS: There was considerable intersubject variability in the nicotine and cotinine values. Plasma nicotine levels began to rise about 4 h after ingestion of the capsules, corresponding with the oro-caecal transit time. Cmax nicotine values were 2.2 and 5 ng ml-1, obtained 7 h after the ingestion of 6 and 15 mg, respectively, of the formulation. The corresponding Cmax values for cotinine were 37 and 94.4 ng ml-1, occurring after 9-10 h. The mean for elimination half-lives in the 24 studies, including the 6 and 15 mg doses, for nicotine were 4.3+/-2.7 h and for cotinine 16.8+/-7.5 h. With 6 mg nicotine-carbomer, only 1 of 12 volunteers had possible side-effects, but with the 15 mg dose 11 out of the 12 reported adverse effects which were systemic or gastrointestinal in nature-their timing corresponded with peak serum concentrations of nicotine. CONCLUSIONS: An oral formulation of nicotine has been developed; in the ileum and colon, this becomes available for slow linear release over 6 h and delivers high concentrations of nicotine for topical effect on the colon. 6 mg Nicotine was well tolerated, whilst 15 mg gave both systemic and gastrointestinal side-effects. High concentrations of topical nicotine in the colon are achieved with relatively low systemic bioavailablity-reflected by the Cmax and AUC values for nicotine. This, or comparable formulations, may be of therapeutic value in ulcerative colitis.

Absorption↗

An ex vivo investigation to compare orthodontic bonding using a 4-META-based adhesive or a composite adhesive to acid-etched and sandblasted enamel.

OBJECTIVE: This study investigates the shear-peel orthodontic bond strengths of brackets bonded with an unfilled acrylic resin containing 4-META (MCP Bond or a no-mix composite adhesive (Right On) to acid-etched or sandblasted enamel. DESIGN: Ex vivo. MATERIALS AND METHODS: Eighty human pre-molar teeth were separated into four equal groups, according to the adhesive used and method of enamel pre-treatment. Group I-Right On with enamel etched using phosphoric acid for 30 seconds. Group II-Right On with enamel sandblasted using 50- microm alumina particles at 80 psi for 3 seconds. Group III-MCP Bond with enamel etched using phosphoric acid for 30 seconds. Group IV-MCP Bond with enamel sandblasted using 50- microm alumina particles at 80 psi for 3 seconds. Subsequently, the specimens were stored in distilled water for 24 hours prior to bond strength testing using an Instron universal testing machine. Each debonded tooth was scored using the adhesive remnant index (ARI) to determine the site of bond failure. RESULTS: The mean bond strength (1 SD) were Group I: 10.7 (2.7) MPa, Group II: 5.3 (1.3) MPa, Group III: 15.9 (3.4) MPa, Group IV: 15.0 (2.2) MPa. Statistical analysis using one-way analysis of variance and Tukey test found no statistical difference between Group III and Group IV (P > 0.05), but the other groups were statistically different from each other (P < 0.05). The data were found to fit the Weibull distribution and Weibull analysis showed stress required for a 5 per cent probability of failure was: Group I: 5.77 MPa; Group II: 3.32 MPa; Group III: 10.31 MPa; Group IV: 10.58 MPa. Chi-square test showed a statistically significant difference existed between the ARI scores (P < 0.001), principally through less adhesive remnants being observed on the sandblasted specimens. CONCLUSION: The adhesive containing 4-META achieved significantly higher bond strengths than the composite adhesive, particularly in the case of sandblasted enamel.

Acid Etching, Dental↗

Factors that affect the adhesion of two irreversible hydrocolloid materials to two custom tray materials.

STATEMENT OF PROBLEM: Little evidence is available on the length of time that adhesive should be allowed to dry before irreversible hydrocolloid impression making. PURPOSE: This study investigated the effect of adhesive drying times on the bond strengths of 2 irreversible hydrocolloid impression materials to 2 "custom" tray materials. MATERIAL AND METHODS: A total of 1,632 specimens were tested: 816 in tensile tests and 816 in tests of the shear bond strength (megapascals) of 2 irreversible hydrocolloid impression materials to an autopolymerizing and a visible light-polymerizing acrylic resin tray material. In the first part of the investigation, a single coat of adhesive was applied to specimen plates that simulated the custom impression tray surface; in the second part, a second coat of adhesive was applied after the irreversible hydrocolloid was removed, and the effect of this second coating on bond strength was examined. In both parts, the adhesive was allowed to dry for a range of times (0 to 8 minutes at 30-second intervals, for a total of 17 time periods) before the addition of the impression material. The specimen plates were placed in a humidor and separated in a universal testing machine operated at a crosshead speed of 100 mm/min with 0- to 5-kN load cell. Data from each of the 1,632 specimens were collected and evaluated with analysis of variance, regression analysis, and t tests (P<.05). RESULTS: Significant differences in mean bond strengths were found between specimens with a 4-minute adhesive drying time (0.179 MPa tensile, 0.068 MPa shear) and specimens with a 0-minute drying time (0.065 MPa tensile, 0.015 MPa shear). Any period over 4 minutes produced no significant difference. The mean bond strengths of the single-coated specimens were 0.179 MPa (tensile) and 0.076 MPa (shear). These values were significantly greater than those for specimens with a second adhesive layer (0.136 MPa tensile, 0.035 MPa shear) over all time periods. Mean tensile bond strengths (0.158 MPa) were consistently higher than shear bond strengths (0.056 MPa) for all combinations of tray material, adhesive application, and time. CONCLUSION: Within the limitations of this study, the results suggest that adhesive applied to the autopolymerized and light-polymerized custom tray materials tested should be allowed to dry for at least 4 minutes before irreversible hydrocolloid is applied. Better results were obtained when the adhesive layer from a failed irreversible hydrocolloid impression was removed and replaced rather than overlaid with an additional adhesive coating.

Acrylic Resins↗

Effect of bleaching agents on the hardness and morphology of enamel.

PURPOSE: The goal of the present laboratory study was to analyze the effect of two home bleaching agents (Opalescence 10%, Ultradent, and Hi-Lite II, Shofu) as well as the separate solutions of 10% carbamide peroxide primary components (3% hydrogen peroxide and 7% urea) on enamel microhardness and surface morphology. MATERIALS AND METHODS: Thirty human molars stored in water for no longer than 3 months were selected. Their facial and lingual surfaces were embedded in acrylic resin, and the specimens were polished with up to 600-grit sandpaper. The 30 molar sections were divided into five groups as per treatment modality (n = 6); group 1, 10% carbamide peroxide bleach with carbopol (Opalescence, Ultradent); group 2, oxygen-free gel bleach (Hydroxylite, Hi-Lite II, Shofu); group 3, 3% hydrogen peroxide with carbopol (Dermus Pharmacy, Florianópolis, SC, Brazil); group 4, 7% urea treatment (Dermus Pharmacy); and control, group 5, artificial saliva (Dermus Pharmacy). Prior to treatment, six indentations (Vickers) were made on each of the six surfaces in each group under a load of 100 g for 30 seconds. Bleaching procedure was conducted for 3 hours per day for 2 weeks, the control group excepted. Following each bleaching session, the specimens were washed with deionized water and kept in artificial saliva at 37 degrees C, this solution being changed daily. Pre- and post-treatment microhardness data were analyzed using a two-way analysis of variance. In a similar way, 30 other specimens underwent the same procedures. After the bleaching period, the samples were observed under the scanning electron microscope. RESULTS: Specimens submitted to bleaching treatment with 3% hydrogen peroxide gel as described in this study showed a significant reduction of surface microhardness (p < .0001). The other treatment modalities had no effect on surface microhardness. No morphologic alterations were observed on enamel submitted to bleaching gel of 10% carbamide peroxide (Opalescence), oxygen-free gel (Hi-Lite II, Shofu), or 7% urea solution compared with the control (artificial saliva). However, the specimens bleached for 3 hours per day for 2 weeks with 3% hydrogen peroxide gel presented areas of mild erosion. The effect, nevertheless, was not uniform, occurring with varying intensity on all samples of enamel bleached with 3% hydrogen peroxide. CLINICAL SIGNIFICANCE: Bleaching treatment conducted with two home bleaching agents (Opalescence 10%, Ultradent, and Hi-Lite II, Shofu) had no adverse effects on enamel microhardness or on surface morphology. Bleaching with 3% hydrogen peroxide can have a negative effect on enamel hardness and surface morphology when performed as described in this study.

Acrylic Resins↗

Dimensional change in complete dentures fabricated by injection molding and microwave processing.

STATEMENT OF PROBLEM: Acrylic resin complete dentures undergo dimensional changes during polymerization. Techniques with injection molding and polymerization and microwave polymerization are reported to reduce these changes and thereby improve clinical fit. These dimensional changes need to be quantified. PURPOSE: The purpose of this study was to compare differences in dimensional changes of simulated maxillary complete dentures during polymerization and storage in water after injection molding and conventional polymerization, or microwave polymerization against a control of conventionally packed and polymerized simulated maxillary complete dentures. MATERIAL AND METHODS: Forty identical maxillary denture bases were prepared in dental wax with anatomic teeth. They were invested and the wax eliminated from the molds. Ten specimens each were randomly assigned to 1 of 4 groups. Group 1 was compression molded and conventionally polymerized; group 2 was injection molded and conventionally polymerized (Success); group 3 was injection molded and microwave polymerized (Acron MC); and group 4 was injection molded and microwave polymerized (Microbase). Intermolar width and changes in vertical dimension of occlusion, were determined after polymerization and after storage in water for 28 days. Measurements in triplicate were made between points scribed on the second molar teeth with a traveling microscope (accurate to 0.005 mm). Vertical dimension of occlusion was measured between points scribed on the upper and lower members of an articulator by use of an internal micrometer (accurate to 0.05 mm). Data were analyzed by use of a 1-way analysis of variance with Tukey post-hoc contrasts (P <.05). RESULTS: Polymerization contractions (intermolar widths) for each group were: group 1, -0.24%; group 2, -0.27%; group 3, -0.35%; and group 4, -0.37%. The Microbase specimens had greater shrinkage than conventionally polymerized specimens, but there were no significant differences between the groups. All injection methods had less postpolymerization increase in vertical dimension of occlusion (0.63 to 0.41 mm) than the conventional Trevalon control (0.74 mm), but only group 4 was significantly different (P<.004). After storage in water for 28 days, all specimens increased in vertical dimension of occlusion (0.10% to 0.16%) from polymerization techniques, but there were no significant differences between groups. CONCLUSION: Within the limitations of this study, injection molding resulted in a slightly less increase of vertical dimension of occlusion than conventional polymerization techniques, the difference being significant for Microbase compared with the conventional Trevalon control.

Acrylic Resins↗

Effect of a denture cleanser on weight, surface roughness, and tensile bond strength of two resilient denture liners.

STATEMENT OF PROBLEM: Denture cleansers used in clinical practice can damage resilient denture lining materials. PURPOSE: This study evaluated the effects of a denture cleanser on weight change, roughness, and tensile bond strength on 2 denture resilient lining materials. MATERIAL AND METHODS: Forty specimens of microwave acrylic resin (Onda-Cryl), 30 mm in diameter and 4 mm thick, were prepared to verify weight change and surface roughness. The specimens were divided into 4 groups consisting of 10 specimens each, relined with a resilient liner (Coe Soft or Dentusoft), and treated (Polident or tap water). To evaluate tensile bond strength, 12 specimens were used for each group. All specimens were stored in artificial saliva for 15 days, immersed once a day in Polident or tap water, and evaluated at 0 hours and after 24 hours and 7 and 15 days. Roughness was evaluated by use of a profilometer. Weight changes were recorded in milligrams and expressed as the percentage of weight difference between the periods of evaluation. Tensile bond strength was determined with a universal testing machine. The specimens were placed under tension until failure by a cross-speed of 5 mm/min with a 500 Kg load cell. The type of failure was determined by use of stereoscopic microscopy at original magnification x8. The data were submitted to analysis of variance and compared by Tukey's test (alpha=.05). RESULTS: Specimens immersed in Polident showed higher and significant (P<.05) weight changes (%) than those immersed in water between 24 hours and 7 days (Coe Soft-Polident: 0.48 +/- 0.09; Coe Soft-water: 0.28 +/- 0.09; Dentusoft-Polident: 0.44 +/- 0.16; Dentusoft-water: 0.22 +/- 0.15) and between 7 and 15 days (Coe Soft-Polident: 0.08 +/- 0.04; Coe Soft-water: -0.17 +/- 0.05; Dentusoft-Polident: 0.01 +/- 0.04; Dentusoft-water: - 0.24 +/- 0.03). There was significant difference (P<.05) in roughness (in micrometers), between treatments after 7 days (Coe Soft-water: 4.07 +/- 0.22; Coe Soft-Polident: 3.36 +/- 0.52; Dentusoft-water: 3.68 +/- 0.72; Dentusoft-Polident: 3.26 +/- 0.41) and 15 days (Coe Soft-water: 4.88 +/- 0.29; Coe Soft-Polident:3.53 +/- 0.61; Dentusoft-water: 4.42 +/- 1.12; Dentusoft-Polident: 3.68 +/- 0.37). Tensile bond strength was highest (P<.05) after 15 days (Coe Soft-water: 5.19 +/- 0.93; Coe Soft-Polident: 4.40 +/- 0.38; Dentusoft-water: 4.42 +/- 1.15; Dentusoft-Polident: 4.84 +/- 1.14). Most failures were cohesive (Coe Soft: 76.04% and Dentusoft: 82.29%). CONCLUSION: Within the limitations of this in vitro study, specimens immersed in Polident demonstrated increased weight changes of resilient liners when compared with tap water, but surface roughness and tensile bond strength were unaffected.

Acrylic Resins↗

Spofacryl.

Explore the source record for details and available documents.

Acrylic Resins↗

[Acrylics].

Explore the source record for details and available documents.

Acrylic Resins↗

Influence of temporary cements on bond strength between resin-based luting agents and dentin.

PURPOSE: To examine the influence of temporary cements on the strength of the bond formed between resin-based luting agents and dentin. METHODS: An acrylic resin plate was luted to bovine dentin using one of three temporary cements; HY-Bond Temporary Cement Hard (HYB), Freegenol Temporary Pack (FTP), or Neodyne T (NDT). The control group (CON) was not treated with cement. Following the removal of the temporary cement, each dentin substrate was bonded to a silane-treated ceramic material (IPS Empress) with one of four luting agents; Super-Bond C&B (SCB), Panavia F (PAF), Nexus II (NEX), or Fuji Luting S (FLS). The specimens were immersed in water for 24 hours and the strength of the bond to shearing forces was determined. RESULTS: The bond strengths (in MPa), with statistical categories shown in parentheses were: HYB (25.7, a), CON (23.5, a, b), FTP (19.8, b, c), and NDT (16.8, c, d) for the SCB system; FTP (13.8, d, e), CON (12.9, d, e), NDT (10.6, e, f), and HYB (7.8, f, g, h) for the PAF system; FTP (9.2, e, f, g), CON (7.9, f, g, h), HYB (7.7, f, g, h), NDT (7.1, f, g, h) for the NEX agent; and FTP (5.2, g, h, i), CON (3.7, h, i), NDT (3.0, h, i), HYB (1.6, i) for the FLS agent, (P< 0.05).

Analysis of Variance↗

The effect of serrations on carbon fibre posts-retention within the root canal, core retention, and post rigidity.

The retention in root canals of serrated carbon fibre Composiposts and stainless steel Paraposts was tested under tensile load. Twenty unrestored human roots were endodontically prepared and root filled. Two groups of 10 roots received 1.4-mm Composiposts or 1.25-mm Paraposts luted with a resin cement. The specimens were then embedded in acrylic resin and mounted in an Instron machine. The tensile force (kg) required to dislodge the posts was recorded and analysed with Student's test. The results revealed that there was no significant difference in the retention of either post (P > .05). The rigidty of 10 1.4-mm serrated Composiposts was tested in a three-point bend test in an Instron machine, and the retention of composite cores to 10 of these posts under tensile force was also tested. The results from these tests were compared to previous data from the authors' laboratory and revealed that the serrations significantly reduced the rigidity of the post (P < .001) and increased the retention of a core material (P < .001).

Carbon↗

Esthetic management of congenitally missing lateral incisors with single-tooth implants: a case report.

Achievement of an esthetic single-tooth restoration in the anterior segment is a difficult task for the restorative dentist. A case is described in which two congenitally missing maxillary lateral incisors were replaced with single-tooth implants. A new technique was used to restore the teeth provisionally with a polyethylene ribbon and resin replacement. Light-cured staining systems for acrylic resins and ceramics were employed to customize both the provisional and final restorations.

Adolescent↗