Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Pulsatile Flow”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92Linked to original sources

Mini hemoreliable axial flow LVAD with magnetic bearings: part 1: historical overview and concept advantages.

Intec has been developing an ultra-miniature axial flow left ventricular assist device (LVAD) turbo pump that incorporates non-contacting magnetic bearings specifically designed to eliminate thrombus. The patent pending pump is similar in size to the Jarvik 2000, being 1.0 inch in diameter and having a volume of 25cc. This paper provides two decades of historical background regarding blood pumps and discusses new advances made possible by our contactless design. Design details are left for parts two and three. This LVAD is presently the smallest magnetically suspended turbo pump. It was made possible by use of new 1/2-inch diameter fringing ring magnetic bearings. These axial field bearings are 10 times smaller than equal capacity radial field conventional magnetic bearings currently in development in turbo pumps. Our LVAD is physiologically controllable, without the use of invasive sensors, by directly measuring pump differential pressure with the magnetic bearings. This mechanism will allow attainment of cyclic, closed-loop control of impeller revolutions per minute to achieve a high degree of pressure pulsatility. Pulsatile flow is important in obtaining long-term hemodynamic reliability without thrombus being generated in either the pump or body.

Heart-Assist Devices↗

Foveolar choroidal blood flow in age-related macular degeneration.

PURPOSE: To compare measurements of the foveolar choroidal blood circulation in subjects with nonexudative, age-related macular degeneration (AMD) with those of control subjects. METHODS: Laser Doppler flowmetry was used to assess relative choroidal blood velocity (ChBVel), volume (ChBVol), and flow (ChBFlow) in the center of the fovea. Measurements were obtained in 20 eyes of 20 subjects with 10 or more large drusen, visual acuity of 20/32 or better, and no evidence of choroidal neovascularization. Findings obtained in these subjects were compared with those of 10 eyes of 10 age- and blood pressure-matched control subjects with no large drusen. Foveolar choroidal blood flow measurements were obtained by asking the study participants to fixate on a probing laser beam. RESULTS: No significant differences in average age, blood pressure, or intraocular pressure were observed between subjects with AMD and control subjects. In subjects with AMD, average ChBVol was 0.24 +/- 0.08 (+/- 1 SD) arbitrary units (AU); this value was 33% lower than that of control subjects (0.36 +/- 0.11 AU; two-tailed, independent Student's t-test, P = 0.005). Average ChBVel, conversely, was not significantly different from normal (0.44 +/- 0.07 AU) in subjects with AMD (0.44 +/- 0.10 AU). Average ChBFlow in subjects with AMD (8.7 +/- 3.1 AU) was 37% lower than that of control subjects (13.7 +/- 3.5 AU) (P = 0.0005). Average blood flow pulsatility was 6% higher in subjects with AMD (0.71 +/- 0.15) than in control subjects (0.66 +/- 0.14), but this difference was not statistically significant (P = 0.42). CONCLUSIONS: Average ChBFlow in the nonexudative stages of AMD is lower than that of age-matched controls, and the effect is caused mainly by a decrease in ChBVol. Further studies are needed to elucidate whether decreased ChBFlow plays a role in the development of choroidal neovascularization, and whether ChBFlow measurements may help identify subjects with AMD at risk for developing choroidal neovascularization.

Aged↗

Current concepts of renal hemodynamics in diabetes.

Glomerular hyperfiltration has long been recognized in insulin-dependent diabetes, and has been more recently recognized in patients with non-insulin dependent diabetes mellitus as well. Experimentally, glomerular hyperfiltration has been shown to result from elevations in the glomerular capillary blood flow and the glomerular capillary hydraulic pressure (PGC). Of the hemodynamic determinants of hyperfiltration, it is glomerular hypertension that is most damaging to the glomerulus. Experimental and clinical studies have confirmed that antihypertensive agents that lower PGC more consistently slow the progression of injury than do those that fail to control glomerular hypertension. The pathogenesis of diabetic hyperfiltration is multifactoral. Many mediators have been proposed, including changes due to the altered metabolic milieu, and alterations in endogenous levels of such vasoactive mediators as atrial natriuretic peptide, endothelial-derived relaxing factor, angiotensin II, prostaglandins, thromboxanes, and kinins, among others. It has more recently been suggested that local renal tissue levels, rather than circulating levels, play the more profound role in hemodynamic regulation. For example, the renin-angiotensin system (RAS) appears to be disproportionately active in the renal tissue, potentially explaining the renal vascular responsiveness to angiotensin-converting enzyme inhibition despite absence of systemic RAS activation. Little is yet known of the mechanisms by which glomerular hypertension leads to injury. Innovative new in vitro systems have been developed to address this question. These studies postulate that glomerular hemodynamic factors (shear stress, pulsatile flow) modify the growth and activity of glomerular component cells, inducing the expression of cytokines and other mediators, which then stimulate matrix production and promote structural injury.

Angiotensin II↗

Quantifying CBF with arterial spin labeling.

The basic principles of measuring cerebral blood flow (CBF) using arterial spin labeling (ASL) are reviewed. The measurement is modeled by treating the ASL method as a magnetic resonance imaging (MRI) version of a microsphere study, rather than a diffusible tracer study. This approach, particularly when applied to pulsed ASL (PASL) experiments, clarifies that absolute calibration of CBF primarily depends on global properties of blood, rather than local tissue properties such as the water partition coefficient or relaxation time. However, transit delays from the tagging region to the image voxel are a potential problem in all standard ASL methods. The key to quantitative CBF measurements that compensate for this systematic error is to create a well-defined bolus of tagged blood and to ensure that all of the bolus has been delivered to an imaging voxel at the time of measurement. Two practical technical factors considered here are 1) producing a tagged bolus with a well-defined temporal width and 2) accounting for reduction in magnitude of the tagged magnetization due to relaxation. The ASL approach has the potential to provide a robust estimation of CBF, although the timing of water exchange into tissue and the effects of pulsatile flow require further investigation.

Blood Physiological Phenomena↗

Proximal pulmonary emboli modify right ventricular ejection pattern.

Analysis of the systolic flow velocity curve (SFVC) in the right ventricular outflow tract is considered as an alternative to the tricuspid valve pressure gradient (TVPG) method for echo-Doppler assessment of pulmonary arterial pressure (P(pa)). The present study checked whether or not SFVC is affected by the cause of pulmonary hypertension. Doppler recordings of 86 patients (39 female, aged 55.5+/-15.2 yrs) with acute (AP-PE) or chronic (CP-PE) proximal pulmonary embolism, chronic obstructive pulmonary disase (COPD) or primary pulmonary hypertension (PPH) were retrospectively analysed by two observers unaware of the purpose of the study. Despite having the lowest TVPG (48+/-13 mmHg), patients with AP-PE had the shortest acceleration time (t(acc); 56+/-15 ms) and time to midsystolic deceleration (t(msd); 105+/-16 ms). t(acc) <60 ms in patients with TVPG <60 mmHg had 98% specificity and 48% sensitivity for AP-PE. In PPH, SFVC was less abnormal (t(acc) 64+/-14 ms, t(msd) 125+/-25 ms, both p<0.03) despite having a TVPG twice as high (92+/-12 mmHg, p< 0.001). In contrast to t(acc), TVPG showed strong correlation with direct P(pa) measurements whenever performed (r=-0.43, p=0.02, versus r=0.80, p<0.001; n=30). There was no correlation between t(acc) and TVPG in a pooled study group and SFVC seemed strongly affected by the presence of both AP-PE and CP-PE. While potentially useful for evaluation of the true right ventricular afterload during pulsatile flow conditions, the systolic flow velocity curve does not provide a reliable estimate of pulmonary arterial pressure.

Adult↗

[Correlation analysis of predictive factors of successful implantation in fertilization in vitro].

INTRODUCTION: Endometrial receptivity as isolated predictive factor of successful implantation, with its specifity is determined with numbered factors. PURPOSE: Purpose of this study was to evaluate significance and correlation between relevant factors using appropriate statistical analyses on term of embryo implantation. MATERIAL AND METHODS: Evaluated group contained 85 women whom according different causes of infertility have been determined for assisted reproduction program. Analysed measurements were: endometrial thickness, assessed hyperechogenity in relation with absolute endometrial thickness (HEA relation) and uterine blood flow (pulsatile index-Pi). Simultaneously were analyzed serum estradiol (E2; pg/ml) and progesterone (P; nmol/l) levels. After these evaluations achieved results were processed with standard statistical pack. Beside that were applied parameter and nonparameter tests with aim to test significancy of difference and multiple regressive analyse (Stepwise). RESULTS: Resulted measured parameters have been presented in basic analyse as middle value (Xrs) from all measurements + SD (standard deviation) and significance of difference is tested by mentioned statistical tests (Table 1). Application of Stepwise analyse, "step by step", has used parameter by parameter based on value which has decreased variability and based on achieved correlative coefficient between dependent uneven and complex of independent uneven values. This procedure confirms best correlation between HEA relation and serum progesterone levels and HEA relation in correlation with associated values: P, E2 and endometrial thickness (Table 1). DISCUSSION: Investigation provided till now shows that embryo quality and endometrial receptivity with highest probability determine success of applied assisted reproduction, successful embryonal implantation There is assessed influence of endometrial receptivity represented trough HEA relation using many folded regressive analyse where qualitative endometrial value has been looked with dependency with other parameters gives picture for high determinancy with hormonal activity and with stimulative ovarian activity. This determinancy could be viewed mostly through serum progesterone levels on day of HCG administration. Correlative relation between qualitative endometrial characteristics on day of HCG administration has high value related to progesterone levels. CONCLUSION: Results presented with this research confirm once again complexity characteristic for factors that play final role in embryo implantation in IVF program. There is presented only one aspect related with this problem with aim to contribute quantification importance and assessment rate of mutual influence these factors known till now as relevant.

Blood Flow Velocity↗

Neurocognitive function in patients with ventricular assist devices: a comparison of pulsatile and continuous blood flow devices.

The effect of successful ventricular assist device (VAD) implantation on neurocognitive function in terminal heart failure is uncertain. Additionally, the different impact of continuous versus pulsatile blood flow devices is unknown. A total of 29 patients (mean age 53 years), surviving implantation of a ventricular assist device as bridge to transplantation were prospectively followed (continuous flow: Micromed DeBakey, n = 11; pulsatile flow: Thoratec and Novacor, n = 18). Normative data were obtained in 40 age- and sex-matched healthy subjects (mean age 54 years). Neurocognitive function was objectively measured by means of cognitive P300 auditory evoked potentials before operation (baseline), at intensive care unit (ICU) discharge, and at the 8-week and 12-week follow-up. Before implantation of the VAD, cognitive P300 evoked potentials were impaired (prolonged) compared with age- and sex-matched healthy subjects (p < 0.001). After successful VAD implantation, P300 evoked potentials markedly improved compared with before operation (ICU discharge, p = 0.007; 8-week follow-up, p = 0.022; 12-week follow-up, p < 0.0001). Importantly, there was no difference between continuous and pulsatile VADs (before operation, p = 0.676; ICU discharge, p = 0.736; 8-week follow-up, p = 0.911 and 12-week follow-up, p = 0.397; respectively). Nevertheless, P300 peak latencies did not fully normalize at 12-week follow-up compared with healthy subjects (p = 0.012). Successful VAD implantation improves neurocognitive impairment in patients with terminal heart failure. Importantly, this effect is independent of the type of VAD (pulsatile vs. continuous blood flow).

Austria↗

Pulsatile ocular blood flow: the effect of the Valsalva manoeuvre in open angle and normal tension glaucoma: a case report and prospective study.

AIM: A case of severe normal tension glaucoma is reported in a trumpet player, along with a study investigating the association between glaucoma and raised intrathoracic pressure, using measurements of pulsatile ocular blood flow (POBF). METHODS: Three patient groups were studied; normals (n = 34), untreated primary open angle glaucoma (POAG) (n = 20), and untreated normal tension glaucoma (NTG) (n = 22), with a total of 76 patients who underwent measurements of POBF using the OBF pneumotonometer at rest and while forcibly exhaling through a mouthpiece connected to a mercury manometer (30 mm Hg) (Valsalva manoeuvre). RESULTS: POBF fell during Valsalva in all groups with the greatest predictor being the resting value of POBF. There was no evidence of significant differences in the mean change in POBF occurring during the Valsalva manoeuvre for the three groups studied before or after adjusting for the sex, the resting POBF, and the resting IOP of the patients (p = 0.294 and p = 0.542, respectively). However, statistically significant associations were found between the change in POBF and sex (p = 0.049), resting POBF (p<0.0001) and resting IOP (p = 0.032). Males had a greater drop, on average, in POBF during Valsalva manoeuvre than females after adjusting for the other factors. Additionally, there was a significant difference in the mean change in IOP during Valsalva for the three groups (p = 0.002), with the difference occurring between the normal and POAG groups (p<0.005). The POAG group had, on average, a drop in IOP during Valsalva, while the other two groups had an increase in IOP. Also noted was a significant difference in the distributions of the risk factors among the three groups (p = 0.002). CONCLUSIONS: This study demonstrates no difference between groups with respect to resting or Valsalva POBF, but does demonstrate a possible trend with respect to IOP, with a drop in IOP occurring during Valsalva in the POAG group. There is, however, much variability in the data left unexplained by our models. Thus, unfortunately, we cannot advise our trumpet player whether his NTG is directly related to his trumpet playing.

Age Factors↗

Isolated popliteal segment v tibial bypass. Comparison of hemodynamic and clinical results.

Clinical and hemodynamic results of isolated popliteal segment, tibial, and sequential bypass grafts were compared in a retrospective review. Results were good with vein grafts to either an isolated segment or infrapopliteal vessel, with five-year patency rates of 71% and 72%, respectively. Prosthetic grafts performed poorly in both groups, and sequential grafts appeared advantageous in such circumstances. Average ankle pressure increased 49 mm Hg following successful isolated segment grafts. Although less than with patent tibial or sequential grafts, improvement was sufficient to relieve rest pain in all instances and heal ischemic lesions or local amputations in all but four patients. If an adequate vein is available and a good tibial vessel exists, distal grafting may be elected, particularly if advanced ischemic lesions demand restoration of pulsatile flow to the foot. If such conditions are not present, isolated segment grafting will give highly satisfactory results.

Aged↗

Imaging subcortical auditory activity in humans.

There is a lack of physiological data pertaining to how listening humans process auditory information. Functional magnetic resonance imaging (fMRI) has provided some data for the auditory cortex in awake humans, but there is still a paucity of comparable data for subcortical auditory areas where the early stages of processing take place, as amply demonstrated by single-unit studies in animals. It is unclear why fMRI has been unsuccessful in imaging auditory brain-stem activity, but one problem may be cardiac-related, pulsatile brain-stem motion. To examine this, a method eliminating such motion (using cardiac gating) was applied to map sound-related activity in the auditory cortices and inferior colliculi in the brain stem. Activation in both the colliculi and cortex became more discernible when gating was used. In contrast with the cortex, the improvement in the colliculi resulted from a reduction in signal variability, rather than from an increase in percent signal change. This reduction is consistent with the hypothesis that motion or pulsatile flow is a major factor in brain-stem imaging. The way now seems clear to studying activity throughout the human auditory pathway in listening humans.

Auditory Cortex↗

Photocurable surgical tissue adhesive glues composed of photoreactive gelatin and poly(ethylene glycol) diacrylate.

This article presents a novel photochemically driven surgical tissue adhesive technology using photoreactive gelatins and a water-soluble difunctional macromer (poly(ethylene glycol) diacrylate: PEGDA).The gelatins were partially derivatized with photoreactive groups, such as ultraviolet light (UV)-reactive benzophenone and visible light-reactive xanthene dye (e.g., fluorescein sodium salt, eosin Y, and rose bengal). A series of the prepared photocurable tissue adhesive glues, consisting of the photoreactive gelatin, PEGDA, and a saline solution with or without ascorbic acid as a reducing agent, were viscous solutions under warming, and their effectiveness was evaluated as hemostasis- and anastomosis-aid in cardiovascular surgery. Regardless of the type of photoreactive groups, the irradiation of the photocurable tissue adhesive glues by UV or visible light within 1 min produced water-swollen gels, which had a high adhesive strength to wet collagen film. These were due to the synergistic action of photoreactive group-initiated photo-cross-linking and photograft polymerization. An increase in the irradiation time resulted in increased gel yield and reduced water swellability. A decrease in the molecular weight of PEGDA and an increase in concentration of both gelatin and PEGDA resulted in reduced water swellability and increased tensile and burst strengths of the resultant gels. In rats whose livers were injured with a trephine in laparotomy, the bleeding spots were coated with the photocurable adhesive glue and irradiated through an optical fiber. The coated solution was immediately converted to a swollen gel. The gel was tightly adhered to the liver tissue presumably by interpenetration, and concomitantly hemostasis was completed. The anastomosis treatment with the photocurable glue in the canine abdominal or thoracic aortas incised with a knife resulted in little bleeding under pulsatile flow after declamping. Histological examination showed that the glues photocured on rat liver surfaces were gradually degraded with time in vivo with infiltration of inflammatory cells and connective tissues without necrotic sign in surrounding tissue. In addition, in the laparoscopic surgery, percutaneous delivery of the glue and its in situ photogelation on rat liver surfaces were demonstrated using a specially designed fiberscope. These results indicate that the photocurable glues developed here may serve as a biodegradable tissue adhesive glue usable in cardiovascular surgery and endoscopic surgery.

Anastomosis, Surgical↗

Assessment of hemodynamics properties of a new-type artificial heart valve prosthesis using catheterization and echocardiography.

OBJECTIVE: The objectives of this study were to assess the hemodynamic properties of the newly developed artificial heart valve prosthesis experimentally in laboratory simulation, in an animal model, and clinically in a human model and to compare the results measured by catheterization and echocardiography. METHODS: (1) Laboratory simulation. The prosthesis was tested using a pulsatile flow simulator in the aortic position. Hydrodynamics parameters were automatically analyzed through a custom-designed data processing program. (2) Animal experiment. Six sheep subjected to mitral replacement with 21-mm-valve prosthesis were measured by open cardiac catheterization intraoperatively. Doppler echocardiography and open cardiac catheterization under dobutamine stress were performed in two sheep subjected to implantation 2.5 years ago. (3) Clinical patient observation. Observations were carried out on 14 patients with aortas replacement and 10 patients with bicuspid replacement using both doppler echocardiography and open cardiac catheterization. RESULTS: (1) Laboratory simulation. The results showed that the value of the transvalvular gradient (DeltaP) decreased with the increase of heart rate, and the values were not greater that 10 mm Hg at any given tissue annulus diameter. (2) Animal experiment. The mean DeltaP value of the six sheep was 5.2 +/- 1.7 mm Hg intraoperatively, while the corresponding DeltaP value of the two sheep 2.5 years after implantation was 6.1 +/- 0.3 mm Hg measured by open cardiac catheterization. (3) Clinical patient observation. The mean DeltaP values in the aortic position measured by catheterization and echocardiography were 6.26 approximately 4.10 and 9.42 approximately 7.48 mm Hg, respectively. The gradients in the mitral position were 2.10 approximately 1.9 and 5.28 approximately 4.10 mm Hg, respectively. CONCLUSIONS: The results demonstrate that the new-type bileaflet heart valve prosthesis only generates a relatively low transvalvar gradient and thus has good hemodynamic properties.

Adult↗

Limiting brain and lung damage after coronary artery bypass grafting: an alternative to conventional coronary artery bypass graft.

The development of coronary artery bypass graft (CABG) for the treatment of coronary heart disease has resulted in reduced morbidity and mortality compared with medical therapy. Even with the rapid development of improved percutaneous interventions, CABG remains an important approach for treating patients with advanced coronary heart disease. However, recent studies and commentary reporting an alarmingly high incidence of subtle, cognitive decline following CABG have generated questions about whether these adverse outcomes could be lessened. Even after considerable study, there is no consensus as to the cause of brain and lung injury after CABG and cardiopulmonary bypass, nor an agreed upon, mechanistic approach to study its prevention. The potential causes of these adverse outcomes and a simple approach are described, involving the use of the cannulae, biventricular pulsatile flow pump, and a blood substitute to optimize the perfusion of brain and alveolar cells, minimize systemic microembolization, and limit post-CABG cognitive decline.

Blood Substitutes↗

A model of thrombin inactivation in heparinized and nonheparinized tubes with consequences for thrombus formation.

The role of flow and mass transport in determining procoagulant concentration at the wall of synthetic and natural cylindrical blood vessels is analyzed theoretically. The model assumes steady laminar flow and considers, in addition to the fluid dynamic parameters, three rate-determining steps: production of procoagulant (thrombin) and its inactivation at the wall, as well as inactivation in the fluid bulk. The ratio of thrombin wall concentration to production rate Cw/N emerges as a critical parameter in characterizing the behavior of the tube wall. With a wall-inactivation rate typical of heparinized materials, Cw/N = 11.1 s/cm, independent of flow (shear rate) and axial position. This is significantly less than the range of Cw/N (50-500 s/cm) for which the thrombin concentration is high enough to result in significant fibrin formation and thrombosis. Hence little fibrin formation and a high degree of thromboresistance is expected for heparinized materials. Nonheparinized materials have Cw/N values above this range, which are only weakly dependent on shear rate and diameter, suggesting that flow-induced dispersion of thrombin (or other procoagulants) has limited impact on the thrombin wall concentration. These latter results appear to refute the conventional wisdom that attributes the relative patency of large-diameter vessels and differences between venous and arterial thrombi to such flow effects. It is likely that additional factors such as flow pulsatility and wall geometry must be considered to account for these observations.

Blood Coagulation↗

Porous hybrid structures based on P(DLLA-co-TMC) and collagen for tissue engineering of small-diameter blood vessels.

Poly (D,L-lactide)-7co-(1,3-trimethylene carbonate) [P(DLLA-co-TMC)] (83 mol % DLLA) was used to produce matrices suitable for tissue engineering of small-diameter blood vessels. The copolymer was processed into tubular structures with a porosity of approximately 98% by melt spinning and fiber winding, thus obviating the need of organic solvents that may compromise subsequent cell culture. Unexpectedly, incubation in culture medium at 37 degrees C resulted in disconnection of the contact points between the polymer fibers. To improve the structural stability of these P(DLLA-co-TMC) scaffolds, a collagen microsponge was formed inside the pores of the synthetic matrix by dip coating and freeze drying. Hybrid structures with a porosity of 97% and an average pore size of 102 mum were obtained. Structural stability was preserved during incubation in culture medium at 37 degrees C. Smooth-muscle cells (SMCs) were seeded in these hybrid scaffolds and cultured under pulsatile flow conditions in a bioreactor (120 beats/min, 80-120 mmHg). After 7 days of culture in a dynamic environment viable SMCs were homogeneously distributed throughout the constructs, which were five times stronger and stiffer than noncultured scaffolds. Values for yield stress (2.8 +/- 0.6 MPa), stiffness (1.6 +/- 0.4 MPa), and yield strain (120% +/- 20%) were comparable to those of the human artery mesenterica.

Blood Vessel Prosthesis↗

Sonographic diagnosis and follow-up of idiopathic hepatic artery aneurysm, an unusual cause of obstructive jaundice.

Hepatic artery aneurysms are rare. We report an idiopathic hepatic artery aneurysm causing obstructive jaundice in a case in which the common hepatic artery arose from the superior mesenteric artery. The diagnosis of hepatic artery aneurysm was suggested by gray-scale sonography, which showed that the common bile duct and intrahepatic biliary radicles were dilated with no obvious intraluminal abnormality and showed no evidence of a mass in the head of the pancreas. A papillotomy of the papilla duodeni major was performed to relieve the cholestasis. Repeat sonography 2 weeks later showed dilatation of the common bile duct and a cyst-like lesion at the porta hepatis impressing the anterior part of the common bile duct. Doppler sonography confirmed pulsatile flow within the cyst-like lesion. Helical CT showed a well-circumscribed lesion with a density similar to that of the abdominal aorta, and mesenteric angiography showed a 3-cm, smooth aneurysm arising from the common hepatic artery, which originated from the superior mesenteric artery. The aneurysm was successfully treated with transcatheter embolization.

Aneurysm↗

Pseudoaneurysm of the dorsalis pedis artery: color Doppler sonographic and angiographic findings.

Pseudoaneurysm of the dorsalis pedis artery is an uncommon condition that is usually caused by a traumatic injury or an iatrogenic intervention. The patient usually complains of an enlarging painless, pulsatile mass. A tentative diagnosis may be made by palpation of the pulsatile mass and detection of an associated systolic bruit. Color Doppler sonographic and arteriographic examinations can be used to confirm the diagnosis. We report the case of a 17-year-old patient with a posttraumatic pseudoaneurysm of the dorsalis pedis artery. Sonographic examinations revealed pulsatile flow into and out of a cystic structure surrounded by a thick hypoechoic wall and a "to-and-fro" pattern in the neck of the vascular mass; these findings were consistent with the diagnosis of a pseudoaneurysm. Angiography confirmed the diagnosis. The patient was treated with ligation of the artery and resection of the pseudoaneurysm. He recovered well after surgery and remained free of symptoms 3 months postoperatively. We believe that color Doppler sonography should be the procedure of choice for use in diagnosing pseudoaneurysms; arteriography can then be used to evaluate the alternative blood supply before surgery is undertaken.

Adolescent↗