Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “IONIZATION”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92Linked to original sources

Origin of the conformation dependence of protein charge-state distributions in electrospray ionization mass spectrometry.

The influence of tertiary structure on the electrospray ionization mass spectra of proteins is a well known and broadly exploited phenomenon. However, the underlying mechanism is not well understood. This paper discusses the bases and the implications of the two current hypotheses (solvent accessibility and Coulombic repulsions), pointing out the remaining open questions. Evidence reported here supports a third hypothesis, i.e. that intramolecular interactions in folded proteins play a key role in determining the observed charge-state distributions. It is proposed that native protein structures stabilize to a large extent pre-existing charges of the opposite polarity to the net charge of the ion, preventing their neutralization during the electrospray process. Thus, the higher charge states of unfolded conformations, relative to the folded structure, would not derive from a more extensive ionization of the former, but rather from a higher content of neutralizing charges in the latter. This interpretation allows several other problematic observations to be explained, including the different shapes of the spectra of folded and unfolded proteins, the discrepancies between observed and predicted gas-phase reactivity of protein ions and the apparent inconsistency of positive- and negative-ion mode results.

Animals↗

Direct stereochemical assignment of hexose and pentose residues in flavonoid O-glycosides by fast atom bombardment and electrospray ionization mass spectrometry.

Mass spectrometric methods have been developed which allow the direct stereochemical assignment of terminal monosaccharide residues in flavonoid O-glycosides without the need for chemical hydrolysis. Standards containing a glucose, galactose, mannose, xylose, arabinose or apiose residue were examined because these monosaccharides are by far the most commonly encountered in flavonoid glycosides. Following acetylation, the major peracetylated sugar related fragments, generated by fast atom bombardment (FAB) or electrospray ionization (ESI), were selected for collisional activation employing a broad range of collision energies. Both FAB and ESI proved to be useful as ionization techniques. Stereoselective fragmentation was achieved and allowed us clearly to differentiate and characterize isomeric monosaccharide residues. The method developed was successfully applied to an unknown flavonoid containing a terminal pentose and hexose residue which was isolated from Farsetia aegyptia.

Flavonoids↗

Effect of instrument tuning on the detectabilityof biopolymers in electrospray ionization mass spectrometry.

Electrospray ionization mass spectrometry of multiply charged biopolymer ions of different molecular size revealed a strong influence of tuning parameters on their detectability in quadrupole ion trap and triple quadrupole mass spectrometers. Hence, after optimizing the ion optical parameters with the signal of the 4- charge state of (dT)(24) (low charge state tuning), a tenfold increase in the signal-to-noise ratio for a mixture of oligodeoxythymidylic acids (n = 12-18) was obtained compared with the results achieved with tune parameters optimized with a synthetic 80-mer oligodeoxynucleotide. By contrast, a detection limit in the upper femtomole region could only be reached for a 104-mer oligodeoxynucleotide utilizing the 24- charge state of the 80-mer (high charge state tuning). The same effect was observed for proteins investigated in the positive ion mode using low and high charge states of cytochrome c and carbonic anhydrase, respectively, for instrument tuning. By comparing the settings for low and high charge state tuning, it became obvious that the most significant difference was observed in the potential applied to the heated metal capillary used to transfer ions from the atmospheric pressure to the vacuum region of the ion source. Taking advantage of the optimized tuning procedure, the molecular mass of a 61 base pair product of polymerase chain reaction was accurately determined by electrospray ionization mass spectrometry on-line interfaced to ion-pair reversed-phase high-performance liquid chromatography.

Base Sequence↗

Structural characterization and isomer differentiation of chalcones by electrospray ionization tandem mass spectrometry.

A series of chalcones were characterized by electrospray ionization tandem mass spectrometry (MS(n)). Several ionization modes were evaluated, including protonation, deprotonation and metal complexation, with metal complexation being the most efficient. Collision-activated dissociation (CAD) was used to characterize the structures, and losses commonly observed include H(2), H(2)O, CO and CO(2), in addition to methyl radicals for the methoxy-containing chalcones. CAD of the metal complexes, especially [Co(II) (chalcone-H) 2,2'-bipyridine](+), allowed the most effective differentiation of the isomeric chalcones with several diagnostic fragment ions appearing upon activation of the metal complexes. MS(n) experiments were performed to support identification of some fragment ions and to verify the proposed fragmentation pathways. In several cases, MS(n) indicated that specific neutral losses occurred by stepwise pathways, such as the neutral loss of 44 u as CH3* and HCO*, or CH(4) and CO, in addition to CO(2).

Chalcone↗

Exact mass measurement on an electrospray ionization time-of-flight mass spectrometer: error distribution and selective averaging.

An automated, accurate and reliable way of acquiring and processing flow injection data for exact mass measurement using a bench-top electrospray ionization time-of-flight (ESI-TOF) mass spectrometer is described. Using Visual Basic programs, individual scans were selected objectively with restrictions on ion counts per second for both the compound of interest and the mass reference peaks. The selected "good scans" were then subjected to two different data-processing schemes ("combine-then-center" and "center-then-average"), and the results were compared at various ion count limit settings. It was found that, in general, the average of mass values from individual scans is more accurate than the centroid mass value of the combined (same) scans. In order to acquire a large number of good scans in one injection (to increase the sampling size for statistically valid averaging), an on-line dilution chamber was added to slow down the typically rapid mass chromatographic peak decay in flow-injection analysis. This simple addition worked well in automation without the need for manual sample dilution. In addition, by dissolving the reference compound directly into the mobile phase, manual syringe filling can be eliminated. Twenty-seven samples were analyzed with the new acquisition and process routines in positive electrospray ionization mode. For the best method found, the percentage of samples with RMS error less than 5 ppm was 100% with repetitive injection data (6 injections per sample), and 95% with single injection data. Afterwards, 31 other test samples were run (with MW ranging from 310 to 3493 Da, 21 samples in ESI+ and 10 in ESI- mode) and processed with similar parameters and 100% of them were mass-calculated to RMS error less than 5 ppm also.

Automation↗

An atmospheric pressure chemical ionization study of the positive and negative ion chemistry of the hydrofluorocarbons 1,1-difluoroethane (HFC-152a) and 1,1,1,2-tetrafluoroethane (HFC-134a) and of perfluoro-n-hexane (FC-72) in air plasma at atmospheric pressure.

A report is given on the ionization/dissociation behavior of the title compounds within air plasmas produced by electrical corona discharges at atmospheric pressure: both positive and negative ions were investigated at different temperatures using atmospheric pressure chemical ionization mass spectrometry (APCI-MS). CHF(2)CH(3) (HFC-152a) undergoes efficient ionic oxidation to C(2)H(5)O(+), in which the oxygen comes from water present in the plasma. In contrast, CF(3)CH(2)F (HFC-134a) does not produce any characteristic positive ion under APCI conditions, its presence within the plasma being revealed only as a neutral ligand in ion-molecule complexes with ions of the background (H(3)O(+) and NO(+)). Analogously, the perfluorocarbon FC-72 (n-C(6)F(14)) does not produce significant positive ions at 30 degrees C: at high temperature, however, it undergoes dissociative ionization to form many product ions including C(3)F(6)(+), C(2)F(4)(+), C(n)F(2n+1)(+) and a few families of oxygen containing cations (C(n)F(2n+1)OH(2)(+), C(n)F(2n)OH(+), C(n)F(2n-1)O(+), C(n)F(2n-1)O(2)H(2)(+), C(n)F(2n-2)O(2)H(+)) which are suggested to derive from C(n)F(2n+1)(+) in a cascade of steps initiated by condensation with water followed by steps of HF elimination and H(2)O addition. Negative ions formed from the fluoroethanes CHF(2)CH(3) and CF(3)CH(2)F (M) include complexes with ions of the background, O(2)(-)(M), O(3)(-)(M) and some higher complexes involving also water, and complexes of the fluoride ion, F(-)(H(2)O), F(-)(M) and higher complexes with both M and H(2)O also together. The interesting product O(2)(-)(HF) is also formed from 1,1-difluoroethane. In contrast to the HFCs, perfluoro-n-hexane gives stable molecular anions, M(-), which at low source temperature or in humidified air are also detected as hydrates, M(-)(H(2)O). In addition, in humidified air F(-)(H(2)O)(n) complexes are also formed. The reactions leading to all major positive and negative product ions are discussed also with reference to available thermochemical data and relevant literature reports. The effects on both positive and negative APCI spectra due to ion activation via increasing V(cone) are also reported and discussed: several interesting endothermic processes are observed under these conditions. The results provide important information on the role of ionic reactions in non-thermal plasma processes.

Air↗

Amino acid cluster formation studied by electrospray ionization mass spectrometry.

The association properties of natural and non-natural amino acids were studied in detail using electrospray ionization mass spectrometry. The results show a highly diverse cluster formation behavior of amino acids. There are differences regarding the degree of clustering (average cluster size), the presence or absence of one or several 'magic' clusters of special stability and the influence of chirality on cluster stability. Cluster formation does not show a good correlation with simple physico-chemical properties (such as solubility), indicating that it is a specific process and not only a simple aggregation during evaporation/ionization. A systematic study of cluster formation of serine derivatives reveals that all functional groups play a prominent role in the binding of the magic octamer. The results support the idea of the zwitterionic character of the octamer. Electrospray ionization of the side-chain acetylated serine shows the formation of a very stable tetramer with a strong preference for homochirality. The results suggest that Ser8 is made up of two tetramer subunits, held together by hydrogen bonds of the side-chain.

Amino Acids↗

Online microdialysis-dynamic nanoelectrospray ionization-mass spectrometry for monitoring neuropeptide secretion.

Although mass spectrometric approaches offer a sensitive method for identifying cell-cell signaling peptides, the high salt-containing environment of extracellular solutions often complicates characterization of these microscale samples. Accordingly, we have developed a miniature hollow-fiber microdialysis device optimized for desalting small-volume neuronal samples online, with the device directly connected to a modified dynamic nanoelectrospray ionization assembly interfaced with an ion trap mass spectrometer. Improvements over existing designs include placement of a capillary insert within the microdialysis fiber to minimize volume, as well as the use of a microinjector that enables 1 microl sample injections. We present detailed evaluation of peptide recoveries within the microdialysis fiber by liquid chromatography-electrospray ionization-ion trap-mass spectrometry analysis of tissue homogenate in artificial seawater with and without microdialysis. Analyte recoveries after microdialysis ranged from 6 to 78% with higher recoveries of more hydrophilic peptides, while little correlation between mass and percentage recovery was observed in the range studied (2000 to 6000 Da). Recoveries of peptides were the lowest for the analytes with the highest initial mass spectrometry signal intensity. Finally, we illustrate the utility of this microdialysis device for desalting neuropeptides secreted from preparations of the peptidergic bag cell neurons of the marine mollusk, Aplysia californica. Without microdialysis, the high concentration of salts ( approximately 0.5 M) prevented detection of peptides, whereas following online microdialysis-dynamic nanoelectrospray mass spectrometry of stimulated releasate, three peptides (acidic peptide, acidic peptide 1-24 and delta-bag cell peptide) were detected.

Animals↗

Mechanism of the formation of a dehydrated ion by an unusual loss of oxygen at the 4'-carbonyl group of abscisic acid methyl ester in electron ionization mass spectrometry.

Methyl ester of abscisic acid (ABA), a plant hormone, gives a dehydrated ion at m/z 260 in electron ionization mass spectrometry (EI-MS). This dehydrated ion had been considered to be derived only from the elimination of the tertiary hydroxyl group at C-1'. We found that 34% of the dehydrated ion was formed by elimination of the oxygen atom at the 4'-carbonyl group, and the remaining 66% by elimination of the 1'-hydroxyl group. This unusual elimination of the carbonyl oxygen was shown with [4'-(18)O]ABA methyl ester. Involvement of the 4'-carbonyl oxygen in dehydration was observed in methyl ester of phaseic acid (PA), a natural metabolite of ABA, but not in 1'-deoxy-ABA methyl ester or isophorone. This suggested that the 1'-hydroxyl group was necessary for the elimination of the 4'-carbonyl oxygen. ABA methyl esters labeled with stable isotopes showed that hydrogen atoms at the 1'-hydroxyl group and at C-4 or -5 or -3' or - 5' or -7' were eliminated with the 4'-carbonyl oxygen. These results allow us to propose a formation mechanism of the dehydrated ion derived from the elimination of 4'-carbonyl oxygen and hydrogen atoms at C-4 and 1'-oxygen in ABA methyl ester as follows: first, ionization at the 1'-hydroxyl group occurs to give an ion radical, and the proton at the 1'-oxygen migrates to the 4'-carbonyl oxygen after the bond fission between C-1'-C-6'; second, migration of the proton at C-4 to the 1'-oxygen is followed by migration of the protons at C-5 and C-7' to C-4 and C-5, respectively; finally, the proton at the 1'-oxygen migrates to the 4'-hydroxyl group, and H(2)O at C-4' is eliminated to give the dehydrated ion. Our findings point out that a dehydrated ion is not always derived from the elimination of a hydroxyl group.

Abscisic Acid↗

Effect of stereochemistry on the electrospray ionization tandem mass spectra of transition metal chloride complexes of monosaccharides.

The effect of stereochemistry on the complexation of aldohexoses (glucose, mannose, galactose, allose and talose) and ketohexoses (fructose, tagitose and sorbose) with transition metal chlorides (CoCl(2), NiCl(2), MnCl(2) and ZnCl(2)) has been investigated by electrospray ionization tandem mass spectrometry. Electrospray ionization of methanolic solutions of hexoses containing metal chlorides gave abundant ions corresponding to [M + MetCl](+) and [2M + MetCl](+) which on collision-induced dissociation gave characteristic fragment ions. The fragmentation pathways have been confirmed by examining methyl glucoside and several isotopically labeled glucoses. Eliminations of H(2)O and HCl, C-C cleavages and elimination of metalhydroxychloride are the competing fragmentation pathways observed. All these pathways seem to be influenced by the stereochemistry of the molecule. The fragmentation of the dimeric complexes, [2M + MetCl](+), is also controlled by the stereochemistry of the molecule. The abundance of the product ions corresponding to elimination of HCl is found to increase with increasing number of axial hydroxyl groups in aldohexoses. [2M + MetCl](+) dissociates by elimination of HCl followed by C(2)H(4)O(2) in aldohexose complexes and by elimination of HCl followed by C(3)H(6)O(3) in ketohexose complexes.

Chlorides↗

Determination of lafutidine in human plasma by high-performance liquid chromatography-electrospray ionization mass spectrometry: application to a bioequivalence study.

A rapid, sensitive and specific high-performance liquid chromatography-electrospray ionization mass spectrometry (LC/ESI-MS) method was developed and validated for the first time to determine the concentration of lafutidine in human plasma. After the addition of diazepam (the internal standard, IS) and 1 M sodium hydroxide solution to 0.5-ml plasma sample, lafutidine was extracted from plasma with n-hexane : isopropanol (95 : 5, v/v). The organic layer was evaporated and the residue was redissolved in 200-microl mobile phase. The analyte was chromatographically separated on a prepacked Shimadzu Shim-pack VP-ODS C(18) column (250 x 2.0 mm i.d.) using a mixture of methanol-water (20 mM CH(3)COONH(4)) = 80 : 20 (v/v) as mobile phase. Detection was performed on a single quadrupole mass spectrometer using an electrospray ionization interface and the selected-ion monitoring (SIM) mode. The method showed excellent linearity (r = 0.9993) over the concentration range of 5-400 ng/ml and had good accuracy and precision. The within- and between-batch precisions were within 10% relative standard deviation. The limit of detection was 1 ng/ml. The validated LC/ESI-MS method has been successfully applied to the bioequivalence study of lafutidine in 24 healthy male Chinese volunteers.

Acetamides↗

Induction of radioprotective peroxiredoxin-I by ionizing irradiation.

Results of this study indicate a radioprotective effect of peroxiredoxin-I. Peroxiredoxin-I is an antioxidant that scavenges hydroperoxides, whereas reactive oxygen species are the main mediators of ionizing radiation toxicity. We hypothesized that peroxiredoxin-I might be induced by cellular exposure to radiation and act to protect them against its cytotoxic effects. Western blot and Northern blot analyses were used to assess peroxiredoxin-I protein and mRNA expression. Rat C6 glioma cells were engineered to overexpress sense or antisense human peroxiredoxin-I using retroviral vectors. Clonogenic cell survival was used to assess radiosensitivities of the engineered cells. Ionizing radiation induced peroxiredoxin-I protein and mRNA expression in human HT29 colon cancer and rat C6 glioma cells in a dose- and time-dependent manner over a 24 hr period. To determine the effect of peroxiredoxin-I on radiation responses, C6 glioma cells were engineered to overexpress sense or antisense human peroxiredoxin-I. In clonogenic assays, cells overexpressing peroxiredoxin-I were more radioresistant. Cells transduced with antisense peroxiredoxin-I were marginally more sensitive to radiation toxicity. Irradiation can induce peroxiredoxin-I expression, and the increased peroxiredoxin-I may protect cells from further radiation damage. These results suggest that protection by peroxiredoxin-I may play an important role in the survival of glioma and colon cancer cells in patients undergoing radiation therapy.

Animals↗

Determination of perfluorooctane sulfonate and perfluorooctanoic acid in human plasma by large volume injection capillary column switching liquid chromatography coupled to electrospray ionization mass spectrometry.

Rapid, selective, and sensitive methodology for the quantification of perfluorooctanoic acid (PFOA) and perfluorooctane sulfonate (PFOS) in human plasma using packed capillary liquid chromatography coupled to electrospray ionization ion-trap mass spectrometry has been developed. Plasma proteins were precipitated using acetonitrile and the resulting supernatant was diluted 1+1 with water containing 10 mM ammonium acetate (NH4Ac) prior to injection. Sample volumes of 250 microL were loaded onto a 30 mm x 0.32 mm ID 10 microm Kromasil C18 precolumn by a carrier solution consisting of 10 mM NH4Ac in ACN/H2O (5/95, v/v) at a flow rate of 100 microL/min, providing on-line analyte enrichment and sample clean-up. Backflushed elution onto a 100 mm x 0.32 mm ID 3.5 microm Kromasil C18 analytical column was conducted using an ACN/H2O solvent gradient containing 10 mM NH4Ac. In order to improve the robustness and performance of the method, perfluoroheptanoic acid (PFHA) was used as internal standard. Separation and detection of PFOA, PFHA, and PFOS were achieved within 10 minutes. Ionization was performed in the negative mode in the m/z range 250-550. The method was validated over the concentration range 1-200 ng/mL for PFOA and over the range 5-200 ng/mL untreated plasma for PFOS, yielding correlation coefficients of 0.997 (PFOA) and 0.996 (PFOS), respectively. The within-assay (n = 6) and between-assay (n = 6) precisions were in the range 2.1-9.2 and 5.6-12%, respectively. The concentration limits of detection (cLOD) of PFOA was 0.5 ng/mL while the cLOD of PFOS was estimated to be 0.2 ng/mL in untreated plasma.

Alkanesulfonic Acids↗

Evaluation of the sensitivity of miniaturized liquid chromatography-electrospray ionization-mass spectrometry for pharmaceutical analysis.

LC-ESI-MS is applied frequently in pharmaceutical analysis. The sample amount is generally not restricted, however with LC-ESI-MS, a lack of sensitivity may still be observed with standard-bore LC columns in isocratic mode. Therefore, it was investigated whether increased sensitivity could be achieved by using miniaturized LC-ESI-MS. Seven columns ranging from 0.1 to 4.6 mm ID were tested using several instrument setups. For proper comparison, a sensitivity gain factor (SGF) was introduced. The SGF expresses the extra sensitivity that may be obtained on top of the normal increase of peak concentration, which can be expected when the column ID is reduced. Desogestrel, mirtazapine, and sugammadex sodium were used as test compounds. For desogestrel and sugammadex sodium, the SGF increased up to a factor of 5-13 when the column ID was reduced, indicating enhanced ionization efficiencies at lower flow rates. Optimum sensitivity was found for the 0.3 mm column coupled in combination with a microinjection valve and a dedicated low flow rate interface. For mirtazapine, no increase of SGF was observed when the column ID was decreased. Apparently, the ionization efficiency of this compound is not affected by the flow rate and the spray quality.

Chromatography, High Pressure Liquid↗

Electrospray ionization mass spectrometry of oligonucleotide complexes with drugs, metals, and proteins.

I. Introduction 61 II. Binding of Small Molecules to DNA 62 A. Covalent Binding 62 B. Reversible (Noncovalent) DNA-Binding Agents 65 III. DNA-Metal Ion Complexes 67 A. Platinum Complexes 70 B. Other Metal Ions 73 IV. DNA-Protein Complexes 74 A. Introduction 74 B. ESI-MS of DNA-Protein Complexes 76 C. ESI-MS Analysis of Proteolytic Products of DNA-Protein Complexes 79 D. ESI-MS of Ternary DNA-Protein-Ligand Complexes 80 V. Conclusions 80 Abbreviations 81 References 81 --Interactions of DNA with drugs, metal ions, and proteins are important in a wide variety of biological processes. With the advent of electrospray ionization (ESI) and matrix-assisted laser desorption ionization (MALDI), mass spectrometry (MS) is now a well-established tool for the characterization of the primary structures of biopolymers. The gentle nature of the ESI process, however, means that ESI-MS is also finding application for the study of noncovalent and other fragile biomolecular complexes. We outline here the progress, to date, in the use of ESI-MS for the study of noncovalent drug-DNA and protein-DNA complexes together with strategies that can be employed to examine the binding of small molecules and metal complexes to DNA. In the case of covalent complexes with DNA, sequence information can be derived from ESI-MS used in conjunction with tandem mass spectrometry (MS/MS) and/or enzymatic digestion. MS/MS can also be used to probe the relative binding affinities of drugs that bind to DNA via noncovalent interactions. Overall, the work in this area, to date has demonstrated that ESI-MS and MS/MS will prove to be valuable complements to other structural methods, offering advantages in terms of speed, specificity, and sensitivity. (c) 2001 John Wiley & Sons, Inc.

Animals↗

Liquid chromatography-electron ionization mass spectrometry: fields of application and evaluation of the performance of a Direct-EI interface.

A comprehensive evaluation and a thorough discussion of the fields of possible applications of the Direct-EI interface are described in this review. Direct-EI allows the direct introduction of the effluent from a capillary HPLC column into the electron ionization (EI) ion source of a mass spectrometer. Thanks to the reduced liquid intake and an in-source nebulizer, the interfacing process occurs smoothly and entirely into the ion source. No intermediate interfacing mechanisms of any sort are interposed between the column and the mass spectrometer, thus circumventing any undesired sample loss and minimizing the effort for instrument modification. Theoretically, any GC-MS system can be converted into an LC-MS for EI amenable compounds. Several parameters, crucial for a successful integration of liquid chromatography and mass spectrometry, have been considered in the evaluation of the functioning of such an interface: limit of detection, linearity of response, reproducibility, and chromatographic compatibility. Different mobile phases, also containing non-volatile buffers, were taken into account, demonstrating an outstanding separation flexibility. The entire set of experiments was carried out at different flow rates and temperatures of the ion source. The interface behavior was also tested in real world applications, with mixtures of pesticides, hormones, nitro-PAH, and endocrine-disrupting compounds, allowing picogram level detection and the possibility to record library-matchable, readily interpretable electron ionization mass spectra, for prompt compound characterization and confirmation.

Chromatography, High Pressure Liquid↗

The 'apparent' hydrolysis of alkyl esters during electrospray ionization.

Electrospray ionization (ESI) mass spectrometry was employed to obtain both molecular weight confirmation and structural information for a series of novel alkenyldiarylmethane (ADAM) analogs. The mass spectral data were intended for use during the structure elucidation of ester hydrolysis products formed during an in vitro metabolism study of a series of novel ADAM analogs. The data on the precursor molecules show the presence of the molecular ion peak, [M+H](+), as well as a peak consistent with the hydrolysis product of the original ester ([MH-ROH+H(2)O](+)). However, chemical ionization mass spectrometry, elemental analysis and (1)H NMR data indicated the presence of only the intact diester compounds, suggesting that the formation of the hydrolysis product was an instrumental artifact, i.e., in-beam hydrolysis during ESI or a result of longer ion residence times of the ion trap mass analyzer.

Alkylation↗

Matrix effects during analysis of plasma samples by electrospray and atmospheric pressure chemical ionization mass spectrometry: practical approaches to their elimination.

Some cases of occurrence of matrix effects (mostly ion suppression) in protein-precipitated plasma samples, and their influence on the validity of plasma concentrations and pharmacokinetic parameters, are discussed. The comparison of matrix effects using either electrospray (TurboIonspray, TISP) or atmospheric pressure chemical ionization (APCI) indicated that APCI is less prone to matrix effects. Nevertheless, TISP is usually the first choice of ionization technique since unknown thermally labile metabolites might be present in the plasma samples causing erroneous results. A high impact of ion suppression on the plasma concentrations after intravenous (i.v.) administration was found, depending on the drug formulation (vehicle). Since ion suppression caused significantly lower plasma concentrations (by a factor of up to 5.5) after i.v. dosing, the area under the curve (AUC) was underestimated and the plasma clearance was consequently erroneously high, with an impact on drug candidate selection. By simple stepwise dilution (e.g. 10-fold and 50-fold) of the supernatant of protein-precipitated plasma samples, including all calibration and quality control samples, the matrix effects were recognized and eliminated.

Animals↗