Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Compressive Strength”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92Linked to original sources

Flexural behaviour of post-cured composites at oral-simulating temperatures.

Post-curing treatments have been known to improve the mechanical stability of visible light-cured composites. After individual post-curing treatment, the flexural strength (FS) of four commercial direct/indirect placement composite materials which differ greatly in composition [oligocarbonate dimethacrylate (OCDMA)-based Conquest C & B (CQT), Bisphenol-A glycidyl dimethacrylate (BisGMA)-based Charisma, urethane dimethacrylate (UDMA)-based Concept (CCT), and BisGMA/UDMA-based Dentacolor] was evaluated under water in the temperature range of 12-50 degrees C. A control series was tested in air at room temperature (25 +/- 1 degrees C). Data were analysed using ANOVA and Duncan's test. Flexural strengths overall decreased (20-40%, P < 0.01) with increasing temperatures except with Conquest C & B. Surprisingly, higher FS values were found in wet conditions than in dry conditions at 25 degrees C. UDMA-based materials much more easily undergo softening in water and by temperature change than do BisGMA- or OCDMA-based materials. Post-cured composites can be significantly affected by exposure to oral environments. Different composition determines the degree of influence.

Composite Resins↗

Interrelationship of trabecular mechanical and microstructural properties in sheep trabecular bone.

The ability to evaluate fracture risk at an early time point is essential for improved prognostics as well as enhanced treatment in cases of bone loss such as from osteoporosis. Improving the diagnostic ability is inherent upon both high-resolution non-invasive imaging, and a thorough understanding of how the derived indices of structure and density relate to its true mechanical behavior. Using sheep femoral trabecular bone with a range of strength, the interrelationship of mechanical and microstructural parameters was analyzed using multi-directional mechanical testing and micro-computed tomography. Forty-five cubic trabecular bone samples were harvested from 23 adult female sheep, some of whom had received hind-limb vibratory stimuli over the course of 2 years with consequently enhanced mechanical properties. These samples were pooled into a low, medium, or high strength group for further analysis. The findings show that microCT indices that are structural in nature, e.g., structural model index (SMI) (r2=0.85, p<0.0001) is as good as more density oriented indices like bone volume/total volume (BV/TV) (r2=0.81, p<0.0001) in predicting the ultimate strength of a region of trabecular bone. Additionally, those indices more related to global changes in trabecular structure such as connectivity density (ConnD) or degree of anisotropy (DA) are less able to predict the mechanical properties of bone. Interrelationships of trabecular indices such as trabecular number (TbN), thickness (TbTh), and spacing (TbSp) provide clues as to how the trabecular bone will remodel to ultimately achieve differences in the apparent mechanical properties. For instance, the analysis showed that a loss of bone primarily affects the connectedness and overall number of trabeculae, while increased strength results in an increase of the overall thickness of trabeculae while not improving the connectedness. Certainly, the microCT indices studied are able to predict the bulk mechanical properties of a trabecular ROI well, leaving unaccounted only about 15-20% of its inherent variability. Diagnostically, this implies that future work on the early prediction of fracture risk should continue to explore the role of bone quality as the key factors or as an adjuvant to bone quantity (e.g., apparent density).

Absorptiometry, Photon↗

Titanium casting using commercial phosphate-bonded investments with quick heating method.

The purpose of this study was to investigate the possible use of quick heating method for titanium casting using two commercial investments (Rematitan Plus and Tancovest). The resulting characteristics of the investments with the quick heating method were as follows: residual thermal expansion at the casting temperature was in the range of 0.39 to 0.64%; green strength and fired strength ranged from 4.4 to 10.3 MPa and from 13.8 to 17.6 MPa, respectively. Five full crown titanium castings from each casting condition were obtained using an argon arc melting and gas pressure casting machine. The thickness of cast surface reaction layer was approximately 200 microm, regardless of heating methods or investments. Further, the heating method did not significantly influence either the accuracy or surface roughness of the titanium castings. These results therefore suggested that these commercial investments for titanium could be used for the quick heating method.

Analysis of Variance↗

Cement from magnesium substituted hydroxyapatite.

Brushite cement may be used as a bone graft material and is more soluble than apatite in physiological conditions. Consequently it is considerably more resorbable in vivo than apatite forming cements. Brushite cement formation has previously been reported by our group following the mixture of nanocrystalline hydroxyapatite and phosphoric acid. In this study, brushite cement was formed from the reaction of nanocrystalline magnesium-substituted hydroxyapatite with phosphoric acid in an attempt to produce a magnesium substituted brushite cement. The presence of magnesium was shown to have a strong effect on cement composition and strength. Additionally the presence of magnesium in brushite cement was found to reduce the extent of brushite hydrolysis resulting in the formation of HA. By incorporating magnesium ions in the apatite reactant structure the concentration of magnesium ions in the liquid phase of the cement was controlled by the dissolution rate of the apatite. This approach may be used to supply other ions to cement systems during setting as a means to manipulate the clinical performance and characteristics of brushite cements.

Bone Cements↗

Force production in the rugby union scrum.

In this study, we examined the relationship between anthropometric, strength and power characteristics of rugby forwards, their body position when scrummaging, and their ability to apply force when scrummaging. Force applied to an instrumented scrum machine was measured for 56 players, both individually and as scrum packs. Measurements of body position for individuals were made by digitizing videotape records of the trials. Forty players subsequently had their anthropometry assessed and completed several strength and power tests. Body mass, each component of somatotype, maximal anaerobic power developed on a cycle ergometer, and isokinetic knee extension strength correlated significantly with individual scrummaging force. A regression model (P < 0.001) including body mass, mesomorphy, maximal anaerobic power and hip angle while in the scrummaging position accounted for 45% of the variance in individual scrummaging force. The packs that produced the largest scrummaging forces were, in general, characterized by a greater pack force to sum of individual force ratio than the packs producing lower forces. Our results emphasize the need for a scrum pack to develop technique and coordination as a unit to maximize scrummaging force.

Adult↗

Fracture strengths of provisional restorations reinforced with plasma-treated woven polyethylene fiber.

STATEMENT OF PROBLEM: Fracture strength of interim fixed partial prosthesis is of great concern, especially in long-span restorations or areas of heavy occlusal stress. PURPOSE: Effects of a plasma-treated woven polyethylene fiber (Ribbond) on the fracture strength of polymethyl methacrylate (Coldpac) and a resin-based two-phase curing provisional restorative material (Provipont DC) were evaluated. MATERIAL AND METHODS: A polyvinyl siloxane template was used to fabricate three-unit posterior provisional prostheses on a stainless steel die with two abutments 22 mm apart. The reinforced groups were fabricated by affixing 3 mm wide pieces of fiber treated with methyl methacrylate monomer or polyisocyanate (activator part of Provipont DC) on the occlusal surfaces of abutments. The interim materials were mixed, according to the manufacturers' specifications, and placed in the template. The template was pressed on the die and held secure until complete setting of the material occurred by light curing (Provipont DC) or autopolymerization (PMMA). The specimens were divided into 4 groups of 10 each (A, reinforced Provipont DC; B, unreinforced Provipont DC; C, reinforced PMMA; and D, unreinforced PMMA). A central compressive load force was exerted on the specimen to determine the fracture load of the restorations. RESULTS: The data revealed mean fracture loads of A, 65.59 +/- 11.27 kg; B, 46.59 +/- 14.84 kg; C, 53.46 +/- 7.76 kg; and D, 49.86 +/- 14.44 kg. CONCLUSION: Plasma-treated polyethylene reinforced PMMA restorations showed no significant increase in fracture loads when compared with unreinforced restorations (p > 0.10), whereas reinforced resin-based restorations revealed significantly higher fracture loads (p < 0.01) than the unreinforced resin-based and PMMA provisional restorations.

Bisphenol A-Glycidyl Methacrylate↗

Mechanical and magnetic properties of nickel-dispersed tetragonal zirconia nanocomposites.

Effects of Ni dispersions on microstructure and mechanical properties have been studied for Y2O3-stabilized tetragonal zirconia (Y-TZP)/Ni nanocomposites with Ni dispersion up to 10 vol%. Composites were successfully fabricated by reducing and hot-pressing Y-TZP/NiO powder mixtures. Fracture strength was significantly improved from 1.5 GPa for monolithic Y-TZP to 1.9 GPa for nanocomposites with a small addition of Ni (1-2 vol%). Magnetic properties of Y-TZP/Ni nanocomposites were also investigated. Magnetization curves of Y-TZP/Ni nanocomposites showed typical hysteresis loops of soft magnetic materials, whereas coercivity was much larger than that of pure Ni metal. A new function arising from magnetomechanical effects of metallic Ni is also discussed for the present nanocomposites.

Compressive Strength↗

Canine cancellous bone microarchitecture after one year of high-dose bisphosphonates.

We examined the effects of one-year high-dose bisphosphonates (risedronate 0.5 mg/kg/day or alendronate 1.0 mg/kg/day) on the three-dimensional (3-D) microstructural and mechanical properties of canine cancellous bone. A high-resolution micro-CT scanner was used to scan cubic specimens produced from the first lumbar vertebrae. Microstructural properties of the specimens were calculated directly from the 3-D datasets and the mechanical properties of the specimens were determined. Our data demonstrate significant microarchitectural changes in the bisphosphonate-treated cancellous bone that was typically plate-like, denser, with thicker and more trabeculae compared with those of the controls. Consistent with architectural changes, the Young's moduli of cancellous bone increased in all three directions with the greatest increase in primary axial loading (cephalo-caudal) direction after treatment. Our results suggest a bone remodeling-adaptation mechanism stimulated by bisphosphonates that increases bone volume fraction, thickens trabeculae, changes trabeculae towards more plate-like, and increases mechanical properties. The secondary degree of anisotropy contributed significantly to the explained variance in bone strength, and the primary or tertiary degree of anisotropy improved the explanation of variances for Young's moduli, i.e., 79% of strength variances or 74-83% of modulus variances could be explained by the combined anisotropy and bone volume fraction. These significant improvements of cancellous bone architecture provide a rationale for the clinical observation that fracture risk decreased by 50% in the first year of bisphosphonate therapy with only a 5% increase in bone mineral density. We conclude that bisphosphonates enhance mechanical properties and reduce fracture risk by improving architectural anisotropy of cancellous bone 3-D microarchitecture.

Alendronate↗

Properties of medium density fiberboards made from renewable biomass.

The goal of this study was to determine the comparative properties of dry-formed medium density fiberboards (MDF) made from renewable biomass (wheat and soybean straw) and those from conventional soft wood fiber. The MDF properties evaluated were modulus of elasticity, modulus of rupture, internal bond strength, thickness swell, and screw holding capacity. The results show that MDF made from wheat straw fiber and soy straw fiber have weaker mechanical and water resistance properties than those made from softwood fiber. Soybean straw is comparable to wheat straw in terms of both mechanical and water resistance properties to make MDF. Water resistance of MDF decreased drastically with increasing straw fiber composition. Wheat straw fiber and soybean straw fiber should be physically or chemically treated to increase their water resistance property for MDF production.

Adhesives↗

Relationship among biomechanical, biochemical, and cellular changes associated with osteoarthritis.

Articular cartilage that lines the surface of long bones is a multilayered material. The superficial layer consists of collagen fibrils and chondrocytes that run parallel to the joint surface. In the deeper layers, the collagen fibrils are more randomly arranged and support vertical units termed chondrons containing rows of chondrocytes. In the deepest layers, the collagen fibrils run almost vertically and ultimately insert into the underlying subchondral bone. Osteoarthritis (OA) is a disease that affects articular cartilage and is characterized by enzymatic and mechanical breakdown of the extracellular matrix, leading to cartilage degeneration, exposure of subchondral bone, pain, and limited joint motion. Changes in mechanical properties of articular cartilage associated with OA include decreases in modulus and ultimate tensile strength. These changes parallel the changes observed after enzymatic degradation of either collagen or proteoglycans in cartilage. Results of recent viscoelastic studies on articular cartilage suggest that the elastic modulus of collagen and fibril lengths decrease in OA and are associated with a loss of the superficial zone and a decreased ability of articular cartilage to store elastic energy during locomotion. It is suggested that osteoarthritic changes to cartilage involve enzymatic degradation of matrix components and fibril fragmentation that is promoted by subsequent mechanical loading.

Animals↗

Influence of the degradation of the organic matrix on the microscopic fracture behavior of trabecular bone.

In recent years, the important role of the organic matrix for the mechanical properties of bone has become increasingly apparent. It is therefore of great interest to understand the interactions between the organic and inorganic constituents of bone and learn the mechanisms by which the organic matrix contributes to the remarkable properties of this complex biomaterial. In this paper, we present a multifaceted view of the changes of bone's properties due to heat-induced degradation of the organic matrix. We compare the microscopic fracture behavior (scanning electron microscopy; SEM), the topography of the surfaces (atomic force microscopy; AFM), the condition of bone constituents [X-ray diffraction (XRD), thermogravimetric analysis (TGA), and gel electrophoresis], and the macromechanical properties of healthy bovine trabecular bone with trabecular bone that has a heat-degraded organic matrix. We show that heat treatment changes the microfracture behavior of trabecular bone. The primary failure mode of untreated trabecular bone is fibril-guided delamination, with mineralized collagen filaments bridging the gap of the microcrack. In contrast, bone that has been baked at 200 degrees C fractures nondirectionally like a brittle material, with no fibers spanning the microcracks. Finally, bone that has been boiled for 2 h in PBS solution fractures by delamination with many small filaments spanning the microcracks, so that the edges of the microcracks become difficult to distinguish. Of the methods we used, baking most effectively weakens the mechanical strength of bone, creating the most brittle material. Boiled bone is stronger than baked bone, but weaker than untreated bone. Boiled bone is more elastic than untreated bone, which is in turn more elastic than baked bone. These studies clearly emphasize the importance of the organic matrix in affecting the fracture mechanics of bone.

Animals↗

Prevention of bone loss in ovariectomized rats: the effect of Salvia miltiorrhiza extracts.

The preventive effect of Salvia miltiorrhiza extracts (SMEs) on the progress of bone loss induced by ovariectomy (OVX) was studied in rats. We measured body weight and bone histomorphometry in sham, OVX or SMEs-administered OVX rats. From light microscopic analyses, a porous or erosive appearances were observed on the surface of trabecular bone of tibia in OVX rats, whereas those of the same bone in sham rats and in SMEs-administered rats were composed of fine particles. The trabecular bone area and trabecular thickness in OVX rats decreased by 50% from those in sham rats, these decreases were completely inhibited by administration of SMEs for 7 weeks. In this study, the mechanical strength in femur neck was significantly enhanced by the treatment of SMEs for 7 weeks. In OVX rats, free T3 was normal in all cases, whereas free T4 was significantly increased. Although there was no difference between OVX and SMEs-administered rats in T3 level, we have found significant difference between them in T4 level. These results strongly suggest that SMEs are effective in preventing the development of bone loss induced by OVX in rats.

Alkaline Phosphatase↗

The role of proximal femoral support in stress development within hip prostheses.

Bone remodeling commonly associated with implant loosening may require revision total hip replacement when there is substantial proximal femoral bone loss. Additionally, the surgical exposure required to remove primary implants may alter the proximal femur's structure. As a result, in many revision hip situations the proximal femur provides compromised support for the revision femoral component. Stress analyses of the proximal femur with extensively porous-coated prosthetic femoral components show that proximomedial femoral bone loss, ununited femoral osteotomy, and periprosthetic fracture can result in significant elevation of stress within revision prosthetic components. The first principal stress within prosthetic components can, in proximal bone loss conditions, be elevated significantly above a revision prostheses' fatigue strength. Loss of proximomedial bone is predicted to increase stress within a revision component by as much as 82%. An unhealed transverse femoral fracture or osteotomy is predicted to more than double the stress within a revision femoral component. In revision total hip replacement, efforts directed toward the restoration of proximal femoral bone and the use of larger prostheses may contribute to avoiding prostheses fatigue fracture. Similarly, protected weightbearing in patients with ununited femoral osteotomies and periprosthetic fractures may be important to preventing prosthetic fracture.

Arthroplasty, Replacement, Hip↗

Municipal sludge as landfill barrier material.

The aim of this research is to find substitute barrier materials for natural clay from two kinds of municipal sludge: waterworks sludge (S(W)) and dredging sludge (Sd). Laboratory tests were performed firstly to determine their Atterberg limits and hydraulic conductivity. Based on the results, the use of waterworks sludge was recommended. Then, shear strength tests were performed and it was found the shear resistance property of waterworks sludge is strong enough to maintain slope stability. In order to evaluate the possibility of secondary pollution, the heavy metal contents of waterworks sludge was determined and the results indicated that secondary pollution is unlikely happened. Finally, economic analysis proves that reusing waterworks sludge as barrier will reduce the lost a great for both landfill and waterworks. Based on the results, waterworks sludge was proposed to use and a further long-term simulated landfill test was suggested.

China↗

Impact strength of acrylic denture base resin reinforced with woven glass fiber.

This study investigated the effect of the number and position of woven glass fibers in denture base resin matrix on its impact strength. Test specimens were reinforced with woven glass fiber 0.5, 1.0, or 1.5 mm below the surface. The impact strength was tested using an Izod-type impact tester with an impact speed of 335 cm/s, which simulates dropping the denture, and using a flywheel-type impact tester with a two-point support at 13.5 and 75.0 cm/s, which simulates the chewing. The woven glass fibers had a strengthening effect in all tests, and the impact resistance was further improved when the woven glass fibers were positioned more superficially in the resin. The results suggest that woven glass fiber is an effective reinforcement in denture base resin.

Analysis of Variance↗

Relationship between fracture toughness and flexural strength in dental porcelains.

The aim of this study was to investigate the correlation between fracture toughness (K(Ic)) and flexural strength (FS) in dental porcelains. Porcelains with different leucite contents and clinical indications were used (A, B, C, D, and E). K(Ic) was determined by surface crack in flexure method (SCF) and FS was determined by four-point-bending test. Microstructural characterization was also carried out. The leucite contents of porcelains A, B, C, D, and E were, respectively, 22, 22, 6, 15, and 0%. Materials with higher leucite content (A and B) presented significantly higher K(Ic) values compared to materials with lower leucite content (C and E). The Weibull moduli (m) of porcelains A and B were statistically higher than those of the other three materials. Regarding characteristic strength (sigma(0)), porcelains D and E showed similar values and statistically higher than those of the other materials which were statistically different from each other. According to the regression analysis, sigma(0) increased with the increase of K(Ic) until approximately 0.75 MPa m(1/2). After that, the increase in K(Ic) was accompanied by a decrease in sigma(0). However, the Weibull modulus increased with the increase in K(Ic), especially for values greater than 0.80 MPa m(1/2).

Aluminum Silicates↗

Influence of osteocalcin and collagen I on the mechanical and biological properties of Biocement D.

In order to generate a calcium-phosphate bone cement as a transient replacement for bone defects, we modified Biocement D (Merck Biomaterial GmbH) containing mineralised collagen with osteocalcin, the most abundant non-collageneous protein of bone. Osteocalcin was added to the cement paste during setting in order to control the crystallisation kinetics of hydroxyapatite (HAP) as well as to stimulate the interaction of osteoblasts and osteoclasts with the bone replacement material. Analysis by SEM and AFM shows, that the addition of osteocalcin causes a nanosize microstructure of the calcium cement, which can be explained by inhibited growth of HAP crystals. The fracture strength of the material decreased by incorporation of osteocalcin, pointing onto a higher defect concentration of the crystalline structure. The impact of osteocalcin onto the interaction of bone cells with HAP-Collagen I-cements was studied in a cell culture system using the human osteosarcoma cell line SAOS-2. Results suggest, that osteocalcin might possibly improve the initial adherence of osteoblast-like cells, whereas proliferation of the cells is not effected.

Biomechanical Phenomena↗

The effect of kyphosis on the mechanical strength of a long-segment posterior construct using a synthetic model.

STUDY DESIGN: This experimental study used synthetic spine models to compare the effect of the angle of kyphosis, rod diameter, and hook number on the biomechanical stiffness of a long-segment posterior spinal construct. OBJECTIVE: To examine the biomechanical effects of incremental kyphosis on variously instrumented long-segment posterior spinal constructs. SUMMARY OF BACKGROUND DATA: Euler's formula for loading of curved long columns would suggest that kyphosis has a profound impact on the biomechanical behavior of long-segment posterior spinal constructs. The effects of sagittal contour on the mechanical properties of long-segment posterior spinal constructs have not been well documented. METHODS: Kyphotic and straight synthetic spine models were used to test long-segment posterior instrumentation constructs biomechanically while varying rod diameter and the number of hook sites. The synthetic spines, composed of polypropylene vertebral blocks and isoprene elastomer intervertebral spacers, were fabricated with either 0 degrees, 27 degrees, or 53 degrees of sagittal contour. The models were instrumented with 5.5- or 6.35-mm titanium rods, and with either 8 or 12 hooks. The models were loaded from 0 to 300 N in a cyclical ramp fashion using an MTS 858 Bionix testing device testing device. Construct stiffness (force and displacement) during axial compression was determined. RESULTS: Straight model: Changing the hook number from 8 to 12 caused a 32% increase in construct stiffness with the 5.5-mm rod. Changing the rod diameter from 5.5 to 6.35 mm caused a 36% increase in construct stiffness with the 8-hook pattern. Changing both the rods and hooks caused the stiffness to increase 44%. 27 degrees MODEL: Changing the hook number from 8 to 12 caused a 20% increase in construct stiffness with the 6.5-mm rod. Changing the rod diameter from 5.5 to 6.35 mm caused a 29% increase in construct stiffness with the 12-hook pattern. Changing both the rods and hooks caused the construct stiffness to increase 26%. 53 degrees MODEL: Changing the hook number from 8 to 12 caused a 14% increase in construct stiffness with the 6.35-mm rod. Changing the rod diameter from 5.5 to 6.35 mm caused a 17% (P<0.0005) increase in construct stiffness with the 12-hookpattern. Changing both rods and hooks caused the stiffness to increase 21%. Summary data on angular kyphosis: Using the same rod diameter and the same number of hooks, and progressing from a straight alignment to 27 degrees of sagittal contour decreased construct stiffness 32%. Going from straight alignment to 53 degrees decreased the stiffness 59.6%. All reported values were statistically significant (P < 0.0005). CONCLUSIONS: The biomechanical stiffness of the straight spine was sensitive to both an increase in hook fixation sites and an increase in rod diameter. The kyphotic spines, however, were more sensitive to variations in rod diameter. Although with increasing kyphosis, the optimum instrumentation strategy will maximize both rod diameter and the number of hook sites, instrumented kyphotic spines remain biomechanically "disadvantaged" as compared with nonkyphotic instrumented spines.

Bone Nails↗