Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ARTIFICIAL LIMBS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92Linked to original sources

A comparison of three measures of progress in early lower limb amputee rehabilitation.

OBJECTIVE: To assess the responsiveness to change and validity of three established outcome measures in relation to early lower limb vascular amputee rehabilitation: the Functional Independence Measure (FIM), the Office of Population Censuses and Surveys Scale (OPCS) and the Amputee Activity Score (AAS). DESIGN: Prospective observational study. SETTING: Inpatient amputee rehabilitation unit. SUBJECTS: Fifty-one consecutive patients admitted for rehabilitation following lower limb amputation for vascular disease. PROCEDURE: To study the responsiveness to change differences between total scores and between subsection scores at different times were analysed. To assess validity, comparisons of the total scores of the measures were made with each other, and the total scores for each measure were compared with other outcomes. RESULTS: Complete scores were obtained on 34 subjects. All measures showed significant change between admission and discharge (p < 0.00001) but only the AAS showed change between discharge and follow-up (p < 0.0001). Subsection analysis revealed expected improvements in mobility. During the inpatient stage progress was also detected in certain activities of daily living in the FIM and OPCS. The measures correlated with each other (p < 0.001). All of the measures' admission scores correlated with duration of stay (OPCS p < 0.005, AAS p < 0.006, FIM p < 0.009) and admission OPCS also correlated with discharge placement (p < 0.036). CONCLUSION: The FIM and OPCS are suitable for the inpatient stage but the AAS would appear to be the best measure at time of discharge and thereafter, and further studies are justified.

Activities of Daily Living↗

[The Borggreve rotation-plasty. A surgical method in therapy of malignant bone tumors and functional results].

From 1980 to 1992, 39 Borggreve-rotation-plasties were performed in patients with malignant bone tumors at the Orthopaedic Clinic of the University of Hamburg. The rotation-plasty was first published in 1930 by Borggreve. Salzer (Wien) described the method in 1981 for the operative treatment of osteosarcomas about the knee. The rotation-plasty is feasible for tumors of the distal femur, even when other limb-saving procedures are impossible, e.g. due to skip metastases, insufficient soft tissue coverage or involvement of the knee joint. The procedure was done on 26 female and 13 male patients, the age ranging between 7 and 45 years with a mean age of 17 years. The histological diagnosis was osteosarcoma in 36 cases, MFH, Ewing's sarcoma and Giant cell tumor in one case, respectively. The operative technique was slightly modified, compared to the method described originally by Salzer. The range of error of the different preoperative imaging procedures was evaluated and compared with the tumor extent in the resected specimen. MRI was found to be most precise. We saw no local recurrencies. Three patients had early thromboses, two of those had to be amputated, slow preoperative compression of the popliteal vein being the main cause in both. One patient developed a lymphatic fistula ten years postoperatively, which was eliminated in a second operation. All patients are followed routinely in the oncologic outpatient service. The functional results were rates "excellent" or "good" for all patients in six of seven categories, according to the Enneking evaluation system.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Measurement of maximal end-weight-bearing in lower limb amputees.

Modern sockets for lower limb amputees utilize total contact and distribute some weight on the stump end. Its tolerance to bear weight varies but is better after joint disarticulation, however, systematic measures have been missing. Different levels, indications, shapes etc. were analysed with 102 measurements in 69 patients. The maximal-end-weight-bearing of the stump measured on a scale was much lower after transmedullar amputations than after disarticulations. Men had a mean tolerance more than 15 kg but women less than 10 kg. There was a positive correlation to body weight. Diabetics tolerated significantly more end-bearing and patients with phantom pain more than patients with stump pain. Within each category of stumps the range of maximal end-weight-bearing was large. Among all below-knee amputees the tolerance was between 2 to 55 kg or 3 to 79 per cent of body weight. Pointed stumps statistically tolerated about as much as rounded ones and the variability of contact surface was not measured as its sensitivity to pain must be unevenly distributed. It is concluded that this simplified method is helpful to analyse pain and to modify end-weight-bearing more individually.

Aged↗

Occlusive vascular disease of lower limbs: diagnosis, amputation surgery and rehabilitation. A review of the Burke experience.

This review is concerned with the epidemiology of lower limb amputations, frequency and results of limbsaving procedures and the contemporary management of dysvascular amputees. National data showed no decline in the number and rates of amputations from 1981-1985, but the frequency of bypass surgery increased indicating that the problem of peripheral arterial occlusive disease is far from being resolved. Femoral/popliteal bypasses are performed twice as often as aorto/ileac procedures but failure rates are high. Based on observations of 238 amputees we noted that femoral/popliteal bypasses had the highest failure rate, particularly when performed as a last limbsaving effort. A laudable trend of preserving the knee was noted but poor stump conditions were the most important factors influencing the length of hospital stay (average 51 days). The amputee rehabilitation process is discussed along with a description of contemporary prosthetic technology. The cost effectiveness of state of the art devices for the older dysvascular amputee is questioned. The cost of amputation and rehabilitation is enormous, especially when preceded by unsuccessful arterial reconstruction. The loss of a leg is, of course, a major disaster for every individual and therefore limbsaving efforts and amputation techniques must be refined and the rehabilitation effort optimized.

Activities of Daily Living↗

Postoperative transcutaneous oxygen measurement in the prediction of delayed wound healing and prosthetic fitting among amputees during rehabilitation. A pilot study.

Postoperative assessment of amputation wound healing remains largely subjective in nature, being based on the physician's clinical judgement. These considerations significantly impact on the rehabilitation course, as premature prosthetic fitting may result in wound breakdown. Alternatively, delayed healing may result in prolonged hospital length of stay. Few attempts have been made to correlate objective parameters of limb perfusion with amputation wound healing or prosthetic fitting outcome during the rehabilitation phase of treatment. A pilot study was conducted, in which the transcutaneous oxygen monitor, a noninvasive device measuring transcutaneous partial pressure of oxygen (tcpO2), was applied to the stumps of 11 consecutive above-or below-knee amputees admitted for rehabilitation after amputation. All patients were tested within 1 wk of admission and 45 days of amputation. The treatment team was blinded as to the test results. A direct correlation was observed between wound healing outcome and tcpO2 results (Fisher's exact test [FET], P = 0.03), and no patient with a tcpO2 of < or 15 mm Hg healed during their rehabilitation stay (FET, P = 0.006). TcpO2 of < or = 15 mm Hg was significantly correlated with prolonged length of stay (Point Biserial Correlation Coefficient [rpbi], = -0.835; P = 0.01), delayed prosthetic fitting (rpbi = 0.742; p = 0.01), and poorer wound healing at admission (rpbi = 0.932; P = 0.001). Postoperative tcpO2 measurement may have use in objectively identifying patients at greater risk of delayed wound healing and prosthetic fitting, although further study is warranted.

Aged↗

The design and testing of a composite lower limb prosthesis.

In unilateral lower limb prosthetic gait, the intact limb, together with the hip on the affected side, strive to compensate for the loss of the missing below-knee musculature. The resultant abnormal gait patterns can eventually lead to pathologies of the spine and other joints. The aim of this research was to design a trans-tibial dynamic elastic response (DER) prosthesis which could simulate the power generation and absorption properties of an intact foot and shank segments. A carbon fibre sickle-shaped prosthesis was developed in which the strain energy from the early part of the stride was stored, and was released again at the point of take-off, to simulate the action of the missing musculature. Stress analysis techniques were used in the design of the prosthesis, for the purposes of computing and maximizing the strain energy of the elements. A force transducer was designed into the prosthesis to verify the analysis. Video motion analyses of the prosthesis were carried out in order to determine the most appropriate shape that would reduce gait asymmetries. The research shows that biomechanical techniques, together with good engineering design and the selection of modern materials, can lead to a prosthesis which approaches the function of a natural foot.

Artificial Limbs↗

The influence of falling, fear of falling, and balance confidence on prosthetic mobility and social activity among individuals with a lower extremity amputation.

OBJECTIVE: To assess in amputee patients the relationship between having fallen in the past 12 months, fear of falling, and balance confidence on mobility capability, mobility performance, and social activity. DESIGN: Population-based survey and chart review. SETTING: Two university-affiliated outpatient amputee programs in southwestern Ontario. PARTICIPANTS: Community-living individuals (n = 435) with a unilateral lower limb amputation. INTERVENTIONS: Patient chart review and a survey questionnaire. MAIN OUTCOME MEASURES: Self-report assessment of prosthetic capability and performance and social activity participation was assessed with the Prosthetic Evaluation Questionnaire mobility subscale, the Houghton Scale, and the Frenchay Activities Index. RESULTS: Falling experiences in the past 12 months were not significantly associated with any outcomes. Fear of falling was important in univariate relationships in all 3 outcomes, but not when balance confidence was included in multivariable modeling. Balance confidence was statistically significant with each of the outcomes and remained significant with inclusion of the covariates. There was statistical interaction (balance confidence x automatism; balance confidence x medication count) in modeling mobility capability and in modeling mobility performance (balance confidence x pain + balance confidence x amputation level). The final models accounted for 70%, 60%, and 55% of the variation in mobility capability, mobility performance, and social activity, respectively. CONCLUSION: Balance confidence was the only factor associated with mobility capability and performance and social activity in the final adjusted models. Clinicians and researchers should consider this variable in the rehabilitation of amputee patients.

Accidental Falls↗

Inter-observer reliability of clinical outcome measures in a lower limb amputee population.

PURPOSE: In an attempt to find a more clinically useful functional outcome measure specifically tailored for lower limb amputees undergoing inpatient prosthetic rehabilitation, a 6-month prospective assessment of inter-rater reliability for Harold Wood-Stanmore Mobility Scale Data, including two handicap scales, was undertaken. An analysis of the data is presented in this paper. METHODS: An inter-rater reliability study was undertaken using four observers to complete admission and discharge scores for the three disability/handicap scales on 14 consecutive patients over 6 months. RESULTS: The disability mobility scale demonstrated perfect observer agreement on admission and at discharge the inter-rater reliability for this measure was high (0.83). By contrast, reliability between observers for admission scores on the handicap mobility scale was poor at 0.49 but reasonably high on discharge (0.83). On admission, inter-rater reliability for handicap physical independence was very low (0.15). At discharge, reliability improved to 0.69 being more consistent with results achieved for the other axes. CONCLUSIONS: This study confirms the good inter-rater reliability demonstrated previously in the literature but reveals poor inter-rater reliability for the two handicap scales. The latter will require modification before they can be used with confidence in conjunction with the disability scale.

Adult↗

Amputees in Limburg: incidence, morbidity and mortality, prosthetic supply, care utilisation and functional level after one year.

OBJECTIVES: To describe for the province of Limburg, the Netherlands, the incidence of lower limb amputation (LLA), the demographic characteristics of the amputees, reason and level of amputation, care the amputees receive, prosthetic supply and functional level after one year. DESIGN: A prospective descriptive cohort study. METHODS: Anonymized data on all amputees in all nine hospitals were collected during 1994. Follow-up was one year. RESULTS: 191 major lower limb amputations in 164 patients. Incidence was 17.1 per 100,000. Amputation levels: 77 trans-tibial, 52 transfemoral and 43 knee disarticulation. Twenty (20) patients died during hospitalisation. Eighty-seven (87) amputees gave permission for followup, 60 could be actually followed. Twenty-two (22) patients received in-patient rehabilitation, 16 primary day-care, 21 went to a nursing home and one went home without rehabilitation. The mean duration of rehabilitation was 35 weeks. In 53 patients a functional prosthesis was indicated. Forty-three (43) of these patients walked with the prosthesis after one year, 7 of whom more than 500 metres. Nineteen (19) amputees performed the Get Up and Go Test (GUGT) safely. Amputees on average have a low level of functioning, as indicated by SIP68 and Barthel Index Scores. The ability to walk is closely related to this daily function and quality of life. CONCLUSION: After one year the majority of amputees have low walking skills and the walking distance is limited. They are often ADL-dependent and their amputation greatly limits their daily function.

Activities of Daily Living↗

Water activity limbs.

With advances in technology there is an increasing availability of Water Activity Limbs (WALs) and subsequently a greater number of requests for their provision. This study aims to establish a national consensus for indications, recommended best practice and procedures. The study was conducted with 2 rounds of questionnaires sent to 40 doctors, prosthetists and therapists each. The first questionnaire had a list of possible tasks requiring a WAL and respondents were asked to record their personal rating for prescription of each of the indications. Following analysis of the 91 responses, a list of indications, guidelines and procedures was sent to the same 120 respondents, enquiring whether they agreed or disagreed to each recommendation. The tasks orientated questionnaire showed that more than 50% of respondents considered occupation as an absolute indication. Other indications were some specific water sports. Occasional swimming and beach activity were only considered as possible indications. Showering was not considered an indication. The second questionnaire showed an overwhelming agreement to most of the procedures and indications recommended except social reasons for leisure. The authors present recommendations for prescription of WALs as guidelines and procedures based on the national consensus amongst peers. They also recommend a process for establishing evidence in a speciality where there is very little published evidence to recommend best practice.

Amputees↗

Beyond the 10-m time: a pilot study of timed walks in lower limb amputees.

OBJECTIVE: To investigate in a pilot study the use of extended walking times as an objective method of distinguishing differences in outcome in lower limb amputees. SETTING: Sixteen lower limb amputees attending the prosthetic clinic. METHOD: Patients were asked to walk 100 m, turning every 20 m, using their usual walking aids and prostheses at their chosen walking speed. Demographic details and modified Stanmore/Harold Wood mobility grades, walking aids used and discomfort were recorded. Time to walk each 20 m up to 100 m was recorded. Statistical analysis was carried out using the Spearman rank order correlation coefficient. RESULTS: There was a wide age range and differing causes of amputation. Five out of 16 subjects failed to complete 100 m and these had the slowest 20- and 40-m times. The mean time to walk 40 m was 41 seconds for those who were able to complete 100 m and 144 seconds for those who could not complete 100 m. All those with modified Stanmore/Harold Wood mobility grades less than four failed to complete 100 m. There was a high correlation between 20-, 40-, 60-, 80- and 100-m times and mobility grades, which was statistically significant, and between 20-, 40-, 60-, 80- and 100-m times. CONCLUSION: Forty-metre walking time can differentiate between those of mobility grades 4b-6 and those with lower mobility grades who are unable to walk significantly outside.

Amputees↗

Cineplasty as a control input for externally powered prosthetic components.

To achieve significant improvement in the function of electric-powered, upper-limb prostheses, we believe it is necessary to develop better control interfaces with inherent sensory feedback. Small cineplasties, or other surgical procedures that also externalize the force and excursion of a muscle, could potentially provide this superior control. Connecting a muscle to a prosthetic component via a controller that embodies the concept of extended physiological proprioception (EPP) would enable the physiological sensory feedback inherent in the skin, muscle, and other tissues of the cineplasty to inform the user of the state of the prosthesis. Multiple miniature forearm tunnel cineplasties, each with an EPP controller, might enable meaningful independent multifinger control of hand prostheses. At higher levels of amputation (e.g., transhumeral), small pectoral or deltoid cineplasties could augment existing control sources to improve control of multifunctional total arm prostheses. To explore the feasibility of these ideas, we quantified the control capabilities of individuals with preexisting biceps muscle tunnel cineplasties with the use of pursuit tracking experiments. A "proof-of-concept" EPP electric hand prosthesis was also successfully developed for a subject with agonist-antagonist, forearm tendon exteriorization cineplasties. The results of the tracking studies demonstrate numerically the efficacy of control by cineplastized muscles relative to other control approaches.

Amputation Stumps↗

Lower extremity residual limb slippage within the prosthesis.

OBJECTIVE: The ability to measure skin surface slippage relative to the internal wall of a lower extremity prosthesis under various loading conditions is important for evaluation of socket fit and function, and creation of finite element models. Skin surface three-dimensional (3D) shape measurements with tracking of fiducial displacements in situ under axial loading of the prosthesis have not previously been reported. Analysis of slippage within the prosthesis has been performed using a new experimental measurement method based on spiral x-ray computed tomography (SXCT) imaging. DESIGN: Small lead markers were placed on the residuum of an adult with a below-knee amputation, and SXCT scans were obtained with the prosthesis in situ under two static axial loading conditions (44.5N and 178N). The 3D scan data were used to assess slippage with three methods: gross displacement of the tibia and distal end of the residuum; relative displacement of markers; and distance measurements between markers. RESULTS: The markers affixed to the below-knee skin surface within the prosthesis were measured. The skin slipped from 2 to 6 mm relative to the internal prosthesis wall when an additional load of 133.5N was applied in the axial direction to the distal end of the prosthesis. The tibial remnant moved 10.0 mm distally relative to the prosthesis internal wall. CONCLUSION: This method provides a feasible means for measuring residuum skin slippage relative to the prosthesis and skin deformation relative to tibia within an in situ prosthesis under load.

Artificial Limbs↗

Mobility outcome following unilateral lower limb amputation.

This study investigated mobility outcome following unilateral trans-tibial or trans-femoral amputation. It was an observational study at the sub-regional amputee rehabilitation centre in Sheffield, UK. All unilateral trans-tibial or transfemoral amputees referred during the study period were included. The Harold Wood Stanmore mobility grade was recorded approximately one year following initial assessment at the centre. Of the 357 amputees referred, complete outcome data was available for 281 (78.7%). The mean age was 68 years (range 16-95), 70.1% were male, and the aetiology of the amputation was vascular or diabetic in 87.5% of cases. Trans-tibial amputations accounted for 50.5% and trans-femoral 49.5%. Almost all trans-tibial and trans-femoral amputees aged 50 and under achieved functional household and community mobility. Approximately 50% of the trans-tibial amputees aged over 50 years gained independent community mobility and around 60% household mobility. There was a significant worsening of community mobility rates with increasing age but for household mobility the differences did not reach statistical significance. Fewer than 25% of trans-femoral amputees aged over 50 achieved community mobility and around 50% achieved household mobility. There was a statistically significant deterioration in both community and household mobility levels with increasing age. This study concludes that mobility rates one year after prosthetic provision for unilateral trans-tibial and trans-femoral amputees worsen with increasing age at amputation and a higher level of amputation.

Adolescent↗

Interface mechanics in external prosthetics: review of interface stress measurement techniques.

Instrumentation to measure accurately the stresses at the interface of a residual limb and prosthetic socket has a strong potential for use in prosthetic treatment. As a tool in the clinical setting, the device would allow a clinician to identify sites of excessive loading, information which could then be combined with clinical assessment of skin quality to determine regions of potential skin breakdown. Stress distributions for different prosthetic designs could be compared, facilitating a clinician's judgement to determine the optimal design for a patient. The instrumentation would have additional use in research as an evaluation tool for computer-based finite-element (FE) models. Stump-socket FE models predict stress distributions for proposed socket designs, thus offering advantages over interface stress measurement because evaluation can be conducted before a prosthesis is fabricated or put on an amputee patient. However, FE models must first be proven valid against experimental measurements before they can be considered accurate predictors of interface stresses. Current interface stress measurement techniques are described, with a concentration on a physical explanation of the advantages and limitations with each technique. New emerging technologies are discussed which are instruments that have been described but for which no data collected on amputees have been reported in the literature. The important new features of those technologies are also discussed.

Amputation Stumps↗

Intra- and inter-rater reliability of the assessment of capacity for myoelectric control.

OBJECTIVE: To examine the reliability of the Assessment of Capacity for Myoelectric Control (ACMC) in children and adults with a myoelectric prosthetic hand. DESIGN: Intra-rater and inter-rater reliability estimated from reported assessments by 3 different raters. PATIENTS: A sample of convenience of 26 subjects (11 males, 15 females) with upper limb reduction deficiency or amputation and myoelectric prosthetic hands were video-taped during a regular clinical visit for ACMC. Participants' ages ranged from 2 to 40 years. METHODS: After instruction, 3 occupational therapists with no, 10 weeks' and 15 years' clinical experience of myoelectric prosthesis training and follow-up independently rated the 30 ACMC items for each patient. The ratings were repeated after 2-4 weeks. Inter- and intra-rater reliability in items was examined by using weighted kappa statistics and Rasch-measurement analyses. RESULTS: The mean intra-rater agreement in items was excellent (kappa 0.81) in the more experienced raters. Fit statistics showed too much variation in the least experienced rater, who also had only good (kappa 0.65) agreement in items. The stability of rater calibrations between first and second assessment showed that no rater varied beyond chance (>0.50 logit) in severity. The mean inter-rater agreement in items was fair; kappa 0.60, between the experienced raters and kappa 0.47 between raters with no and 10 weeks' experience. CONCLUSION: Overall, the agreement was higher in the more experienced raters, indicating that reliable measures of the ACMC require clinical experience from myoelectric prosthesis training.

Adult↗

The biomechanics of one-footed vertical jump performance in unilateral trans-tibial amputees.

This study investigated vertical jumps from single support for two trans-tibial amputees from a standing position. The mechanisms used to achieve flight and the compensatory mechanisms used in the production of force in the absence of plantarflexors are detailed. Two participants completed countermovement maximum vertical jumps from the prosthetic and the sound limbs. The jumps were recorded by a 7-camera 512 VICON motion analysis system integrated with a Kistler forceplate. Flight height was 5 cm jumping from the prosthetic side and 18-19 cm from the sound side. The countermovement was shallower and its duration was less on the prosthetic side compared to the sound side. The reduced and passive range of motion at the prosthesis resulted in an asymmetrical countermovement for both participants with the knee and ankle joints most affected. The duration of the push-off phase was not consistently affected. At take-off the joints on the sound side reached close to full extension while on the prosthetic side they remained more flexed. Joint extension velocity in the push-off phase was similar for both participants on the sound side, though the timing for participant 2 illustrated earlier peaks. The pattern of joint extension velocity was not a smooth proximal to distal sequence on the prosthetic side. The magnitude and timing of the inter-segment extensor moments were asymmetrical for both subjects. The power pattern was asymmetrical in both the countermovement and push-off phases; the lack of power generation at the ankle affected that produced at the remaining joints.

Amputees↗

[Possibilities for quantitative gait analysis in evaluation of prosthesis fit].

Nowadays, the fitting of a lower-limb prosthesis is done mainly on an empirical basis. The main aim of the present study was to provide objective data and presentations to support the subjective data. With the aid of a cybernetic statement, the process of fitting a prosthesis to a human subject was developed as a self-optimizing control cycle. Using this systematic scheme, the walking trial was identified as the process element of this control cycle in which the fitting proper took place. Starting with this systematic scheme, the characteristics of defined changes to the system human-prosthesis during walking were measured with the aid of a specially configured gait analysis system. For the estimation of the characteristics of the measured walking trial, a three stage parameter system based initially only on the angle, velocity and acceleration curves at the knee joint was developed. On the basis of pattern recognition routines, the parameter system permits a very high level of identification of the measurements. The identification of poor fittings not covered by the pattern recognition system is not yet satisfactory. However, with the incorporation of additional gait parameters, it will be possible to further improve the description of the gait, enabling better recognition of disturbances in the human-prosthesis system.

Artificial Limbs↗