Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ACRYLIC RESINS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92Linked to original sources

Post-embedding immunocytochemistry for adhesive proteins and clathrin in LR White- and LR Gold-embedded human platelets.

Two hydrophilic acrylic resins, LR White and LR Gold, were tested for their suitability for post-embedding immunocytochemistry on human platelets. Both resins gave satisfying results with regard to ultrastructural preservation and retention of antigenicity for von Willebrand factor, fibrinogen, fibronectin and clathrin. Embedding in LR White and polymerization at 50 degrees C without accelerator proved to be the best method because it provided clear negative membrane contrast, good immunocytochemical localization of antigens and the entire procedure required a comparatively short time. Label for von Willebrand factor was found in typically eccentric location in alpha-granules, but also in the form of small caps directly outside the granule membranes, beneath the outer plasma membrane and in the cytoplasm. With the exception of the eccentric location within granules, labelling for fibrinogen and fibronectin revealed very similar results. Label for clathrin appeared in the form of small gold clusters attached to alpha-granules, in the cytoplasm and beneath membranes of the open canalicular system. Together with the appearance of coated vesicles attached to granules and to the membranes of the open canalicular system in araldite-embedded material, these results further strengthen the concept that adhesive proteins are taken up from the plasma and stored in granules. Moreover, the persistence of the clathrin coat on vesicles attached to storage granules may also indicate that receptors for adhesive proteins are recycled.

Acrylic Resins↗

Development of oral drug delivery system using floating microspheres.

Floating acrylic resin microspheres with an internal hollow structure were prepared by a solvent diffusion and evaporation method. The yield of microspheres depended on the diffusion rate of ethanol and/or isopropanol in the organic phase. They were successfully produced when a mixture of ethanol and isopropanol was used instead of ethanol alone. The mixing ratio of components in the organic phase affected the size and the yield of microspheres and the best results were obtained at the volume ratio of ethanol:isopropanol:dichloromethane (8:2:5). Direct introduction of the organic phase into the aqueous phase through a glass tube also significantly improved the yield by avoiding the contact of organic phase with the surface of water. The optimum rotation speed and temperature were 250 rpm and 25 degrees C, respectively. Several different drugs with various physico-chemical properties were used as model drugs for encapsulation and release tests. When a drug had low solubility in dichloromethane and high solubility in both water and a mixture of ethanol/isopropanol, the loading efficiency was the lowest. The release profiles were significantly different depending on the solubility of a drug in the release medium and the physico-chemical properties of an encapsulated drug.

2-Propanol↗

Heat transfer of impression plasters to an implant-bone interface.

PURPOSE: The purpose of this in vitro study was to measure heat generated at the implant-bone interface caused by exothermic setting reaction of 2 impression plasters. MATERIALS AND METHODS: The study consisted of 20 titanium-alloy abutment impressions connected to a titanium-alloy cylindrical implant embedded in an acrylic-resin mandible in a 37 degrees C water bath. There were 2 types of impression plaster used, Snow-White (Kerr, Romulus, MI) and Xantano (Kulzer, Dormagen, Germany). Temperature changes were recorded via embedded thermocouples at the cervix and implant surface apex. Analysis of variance for repeated measures was used to compare 2 treatment groups. RESULTS: Temperature increased less at the implant apex (1.5 degrees-2.1 degrees C) than at the implant cervix (7.4 degrees-10.5 degrees C). Differences between the 2 impression plasters were statisticallysignificant only at the implant cervical level (P < 0.05). A lower temperature increase was shown with the Snow-White compared with the Xantano. Although both plasters generated an exothermic reaction on setting (mean temperature change 22 degrees C), the increase in the temperature rate of the Snow-White was slower than the Xantano. CONCLUSIONS: Under the conditions of the present study, Snow-White impression plaster appears to be safer to use in implant prosthodontics compared with the Xantano because of its slower and lower exothermic reaction at the implant-bone interface. However, use of the material with the rapid setting time would require more care, such as limiting the volume of material used (e.g., by using a custom tray).

Acrylic Resins↗

Biochemical composition and cariogenicity of dental plaque formed in the presence of sucrose or glucose and fructose.

The composition of dental plaque formed in the presence of sucrose or glucose and fructose and its relation to cariogenicity was evaluated. Twelve adult volunteers took part in this crossover study done in three phases of 28 days each. For each phase, an acrylic resin appliance containing four human dental enamel blocks was constructed for the volunteers. Solutions containing 20% sucrose or 10% glucose + 10% fructose were dripped onto the enamel blocks 8 times a day, while in the control group no solution was used. Enamel surface and cross-sectional microhardness results showed that dental plaque formed in the presence of sucrose was more cariogenic than that formed in the presence of glucose + fructose (p<0.05). The concentration of alkali-soluble carbohydrates in dental plaque was higher in the sucrose group than in the control and glucose + fructose groups (p<0.05). Although concentrations of Ca, P and F were lower in plaque formed in the presence of sucrose than glucose + fructose and the control, significant differences (p<0.05) were only observed in relation to control. The electrophoretic profile of the matrix proteins of dental plaque showed distinct patterns when it was formed in the absence or presence of the different carbohydrates. Although the results suggest that the high cariogenicity of dental plaque formed in the presence of sucrose can be mainly explained by the high concentration of insoluble glucans of its matrix, the low inorganic concentration and its protein composition may have some contribution.

Acrylic Resins↗

Reliability of preoperative planning of an image-guided system for oral implant placement based on 3-dimensional images: an in vivo study.

PURPOSE: The purpose of this study was to assess the reliability of the planning software of an image-guided implant placement system based on a mechanical device coupled with a template stabilized on soft tissue during surgery. MATERIALS AND METHODS: Thirty consecutive partially or completely edentulous patients were treated with the image-guided system. For each patient, a study prosthesis was fabricated and duplicated in acrylic resin and served as a scanning template. Axial images were obtained from a computerized tomographic scan and transferred to planning software that provides real 3-dimensional information to plan implant position. Once the final position of the implant was defined, preoperative data such as the size of implants and anatomic complications were recorded using the planning software. The scanning template was then drilled in that exact position by a drilling machine. During surgery, the drilled template was used as a drill guide. After implant placement, intraoperative data were recorded and statistically compared with the preoperative data using the Kendall correlation coefficient for qualitative data and the Kappa concordance coefficient for quantitative data. RESULTS: Agreement between the preoperative and intraoperative data was high for both implant size and anatomic complications. The Kendall correlation coefficient was 0.8 for the diameter and 0.82 for the length. The Kappa concordance coefficient was 0.87 for both dehiscence and bone graft, 0.88 for osteotomy, and 1.0 for fenestration. DISCUSSION: In the few instances where planning was not perfect, implant placement was completed in a clinically acceptable manner. CONCLUSION: The results suggest that the image-guided system presented is reliable for the preoperative assessment of implant size and anatomic complications. It may also be reliable for flapless surgery.

Acrylic Resins↗

Immediate loading with complete implant-supported restorations in an edentulous heavy smoker: histologic and histomorphometric analyses.

The clinical case presented is that of an edentulous female patient, a heavy smoker, who received implant-supported complete restorations in the maxilla and mandible using the immediate loading concept according to the Ankylos implant system. The patient received 12 commercially pure titanium (grade 2) Ankylos implants, 6 in the maxilla and 6 in the mandible. The implants were loaded immediately after surgery with temporary acrylic resin prostheses fabricated chairside using a prefabricated customized splint. The definitive ceramometal restorations were seated 4 months after surgery. Clinical and radiologic evaluation at 7 months after implant placement indicated functional bone anchorage of all implants, despite the patient being a smoker and having poor bone quality. The patient died 7 months after implant placement because of lung cancer; however, there was no known disease at the time of implant placement. After her death, the implants with the surrounding tissues were removed en bloc and examined histologically and histomorphometrically using undecalcified cut and ground sections. All implants were osseointegrated to some extent and surrounded by lamellar bone. However, around the upper, nonthreaded parts of the implants, much of the bone had been resorbed. In this region, fibrous connective tissue was in close contact with the titanium surface. Epithelial proliferation with pocket formation could not be observed in any of the implants. The histomorphometric evaluation of bone-implant contact in threads demonstrated a mean of approximately 51% of the available surface and a mean bone volume of approximately 52%, with a tendency toward greater contact and volume around the implants in the maxilla. If the nonthreaded cylindric portions of the implants were included, mean bone-implant contact was 46% and mean bone volume was 47%.

Acrylic Resins↗

Immunoelectron microscopy: a new method for detection of insulin antibodies.

The aim of the present study was to set up a sensitive technical alternative to the classical procedures for detection of human insulin antibodies. We developed a method of post-embedding immunoelectron microscopy (IEM) using as the substrate fresh human pancreas, embedded in acrylic resin to maintain its antigenic structure. The antigen was insulin within the mature secretory granule. Serum samples obtained from 10 patients with insulin antibodies detected at various titers by either radio binding assay (RBA) or enzymatic immunoassay (EIA) were incubated for 2 hr at 37 degrees C at dilutions of 1:25, 1:100, 1:400, 1:1600, 1:6400, 1:25,600, and 1:102,400. The electron microscope photographs were analyzed by computerized morphometry and the number of protein A-gold-IgG complexes was calculated per micron2 of insulin granule. IEM results were compared with those obtained with EIA. The specificity of both techniques towards insulin was assessed as the difference between the signals (number of gold particles per micron2 of insulin granule in IEM or optical density > or = 0.193 in EIA) with and without excess insulin. Sensitivity was defined as the detection limit of the assay. In all the 10 sera investigated, IEM was more sensitive, with a 12- to 40-fold lower detection limit than EIA. IEM, with native insulin granules as substrate, is a specific, reproducible, and sensitive method for detection of human serum insulin antibodies. These findings also suggest IEM as a procedure potentially suitable for identifying antigen specificity of autoantibodies circulating at low concentration.

Acrylic Resins↗

Retention, marginal leakage, and cement solubility of provisional crowns cemented with temporary cement containing stannous fluoride.

PURPOSE: This in vitro study investigated the (1) retention and microleakage of provisional crowns cemented with temporary cements to which stannous fluoride (SnF2) was added, and (2) solubility of these cements. MATERIALS AND METHODS: Provisional crowns were constructed of acrylic resin with shoulder preparations for 12 molars. The crowns were luted with Tempbond, Tempbond NE, and Freegenol temporary cements, and also with SnF2 added to these cements. Specimens were thermocycled 100 times, stored for 6 days, and immersed in 0.5% basic fuschin. Seven days after cementation, crown removal (retention) tests were conducted. Marginal leakage was assessed using a five-level scale to score dye penetration. Solubility in water of the cements with and without SnF2 was assessed using cement disks. RESULTS: Freegenol was more retentive than the other cements. The incorporation of SnF2 significantly increased the retention capacity of Freegenol and Tempbond NE but had no effect on Tempbond. Tempbond showed significantly higher dye penetration than Freegenol. The addition of SnF2 did not alter the dye penetration of the cements. There were no significant differences in the solubility of the cements. However, the incorporation of SnF2 increased the solubility of Freegenol and Tempbond NE (P < .001) and Tempbond (P < .01). CONCLUSION: The addition of SnF2 increased the retention of temporary crowns cemented with Tempbond NE and Freegenol but did not affect the retention of those cemented with Tempbond. The marginal leakage of crowns cemented with the tested temporary cements with and without the incorporation of SnF2 was similar. However, the addition of SnF2 increased the solubility of the cements.

Acrylic Resins↗

Intrathoracic and intraabdominal wall implantation of a centrifugal blood pump for circulatory assist.

An implantable centrifugal pump (ICP) 320 ml in volume and 830 g in weight has been developed for prolonged circulatory assist. The antithrombogenicity of the ICP is provided by a balancing hole in the center of the impeller. The watertightness and histocompatibility of the ICP are supported by its silicone ring seal and its casing of titanium and acrylic resin, respectively. The total efficiency of the ICP was 30% at a 5 L/min flow rate and a 100 mm Hg head. The heat generation, watertightness, and anatomical fitting of the ICP were assessed in an intrathoracic implantation in a goat (66 kg) and in an intraabdominal wall implantation in a goat (70 kg). Warfarin was given for anticoagulation in each experiment to keep the prothrombin time around 1.7 times that of the control. The temperatures of the pump surface, the pleura, and the room were measured every 3 h. Anatomical fitting was evaluated by pathological observation after the termination of the experiment. The ICP could run for 40 days in the chest cavity and for 11 days in the abdominal wall. The temperature of the motor remained about 1.8 degrees C higher than the reference in both experiments. The ICP was completely covered by a layer of smooth fibrous tissue. The moisture content of the seals remained normal. Although a small amount of atelectasis was found in the lingula, neither lung adhesion nor necrotic change of the chest wall was observed. The inflammation of the surrounding tissue including foreign body reaction and thermal burn was minimal. In conclusion, the ICP has satisfied in vivo testing of its watertightness, exothermicity, and anatomical fitting.

Abdominal Muscles↗

Accuracy assessment of image-guided implant surgery: an experimental study.

PURPOSE: To accurately accomplish the drilling of an implant socket, the use of image-guided navigation has become an option. The aim of this study was to evaluate the 3-dimensional (3D) accuracy of navigation-guided drilled holes. MATERIALS AND METHODS: Laboratory accuracy measurements were obtained on an acrylic resin model with standardized target holes drilled by a computerized numerical control machine. The model was scanned by a multislice computerized tomography scanner and registered with fiducial marker-based algorithms. Navigated drillings were performed using an optical navigation system based on passive marker technology. Coordinates of drilled holes were determined by a 3D-digitizer probe, and accuracy was assessed for all 5 degrees of freedom using a computer-aided design system (Pro/Engineer). RESULTS: A total of 240 drillings were evaluated. Mean registration error was 0.86 mm (SD 0.25 mm). Target point deviation between preplanned and actual drill starting point was 0.95 mm (SD 0.25 mm). The deviation in terms of full length was 0.97 mm (SD 0.34 mm), and mean angular deviation on the coronal and sagittal planes was 1.35 degrees (SD 0.42 degrees). DISCUSSION: The accuracy of image-guided navigation depends on imaging modalities, patient-to-image registration procedures, and instrument tracking. The technical accuracy and the navigation procedure, as evaluated in the study presented, seem to be of minor influence. CONCLUSION: The data obtained by this in vitro study demonstrate that the accuracy of navigation-based drilling may be sufficient for clinical practice, particularly in terms of the transferability of preplanned trajectories. However, in vivo clinical trials need to be performed to evaluate the clinical accuracy and treatment quality of navigation-guided interventions.

Acrylic Resins↗

Effects of endodontic instrument handle diameter on electromyographic activity of forearm and hand muscles.

AIM: To determine the influence of the handle diameter of endodontic instruments on forearm and hand muscle activity using electromyographic (EMG) recording. METHODOLOGY: Size 45 K-type files were fitted with four different handle diameters; 3.5, 4.0, 5.0, and 6.0 mm. Seven dentists then attempted to negotiate to the working length acrylic resin root canals with each of the four handle sizes using a reaming motion. EMG activities were recorded from the flexor pollicis brevis muscle (f.p.b.), the flexor carpi radialis muscle (f.c.r.), and the brachioradialis muscle (b) with bipolar surface electrodes. The time taken to negotiate the canals, the area of integrated EMG that corresponded to the amount of EMG activity required during penetration and the maximum amplitude of EMG were measured using the EMG data. Results were analysed statistically using a one-way factorial ANOVA test and multiple comparison tests. RESULTS: Reaming time and integrated EMG area of each muscle decreased with an increase in handle diameter. The most significant difference in time and area of integrated EMG was detected between handles of 6 mm and 3.5 mm diameter (time: P < 0.01, area of the f.p.b.: P < 0.01, area of the f.c.r. and b: P < 0.05), and between handles of 5 mm and 3.5 mm diameter (P < 0.05). Both 5 mm and 6 mm handles significantly decreased the maximum amplitude of EMG recorded from the f.p.b. compared with 3.5 mm handles (between 3.5 mm and 6 mm: P < 0.01, between 3.5 mm and 5 mm: P < 0.05). CONCLUSION: The results indicate that handle diameter has an effect on reaming time as well as on muscle activity. As a consequence, handle diameter influenced operator performance during instrumentation.

Acrylic Resins↗

A pilot study comparing the efficacy of hard and soft stabilizing appliances in treating patients with temporomandibular disorders.

STATEMENT OF PROBLEM: Soft and hard stabilizing appliances have been used to treat temporomandibular disorders. No data exist to suggest whether a hard or soft appliance is beneficial. PURPOSE: This study compared soft and hard acrylic resin stabilizing appliances in the reduction of masticatory muscle pain in patients with temporomandibular disorders. MATERIALS AND METHODS: Twenty-three patients with at least one clinical sign from the list of diagnostic subgroups of temporomandibular disorders were alternately assigned a hard or soft appliance for temporomandibular disorder treatment. No other temporomandibular disorder treatment (self-care, physical therapy, biofeedback, or muscle or joint injections) was rendered. Each patient was seen by two dentists at each visit. One dentist initially fabricated the appliance and adjusted the appliance on each visit and an examining dentist examined the patient each visit and recorded signs of temporomandibular disorders. The appliance material (soft or hard) was not disclosed to the examining dentist, only to the dentist who fabricated and adjusted the appliance. Patients were examined and appliances were adjusted every 2 to 3 weeks for a minimum of 10 weeks. Masticatory muscles were palpated and charted on each visit. Data were analyzed and subjected to nonparametric Mann-Whitney test. RESULTS: Eighteen of the initial 23 patients, 7 in the hard appliance group and 11 in the soft appliance group finished the study over 10- to 15-week period. Soft and hard appliances performed the same in reduction of masticatory muscle pain. CONCLUSION: This study suggests, based on the limited number of participants, that soft and hard stabilizing appliances may be equally useful in reducing masticatory muscle pain in short-term appliance therapy.

Acrylic Resins↗

Immediate loading of single-tooth implants in the anterior maxilla. Preliminary results after one year.

According to the standard protocol, a load-free healing period is one of the most emphasized requirements for implant integration. Recent studies have encouraged a progressive shortening of the healing period for single-tooth implants and immediate loading has been proposed for the aesthetic zone in the maxilla. The present study evaluated clinical outcomes of immediately loaded FRIALIT-2 Synchro implants 12 months after placement in the maxillary incisal region. In the course of our investigation, nine patients have been treated following an immediate loading protocol. The stepped-screw type implants were inserted with an increasing torque up to 45 Ncm, thus measuring the primary stability of the implants. All implants were immediately restored with unsplinted acrylic resin provisional crowns and the patients provided with occlusal splints. Regular controls were performed at monthly intervals, intraoral radiographs were taken directly after implant placement, 6 and 12 months post insertion. The survival rate, clinical stability (Periotest) and radiographic coronal bone defects (CBD) were evaluated at delivery of the definitive superstructures (CBD 6) and 6 months later (CBD 12). Twelve FRIALIT-2 Synchro stepped screws of 3.8, 4.5 and 5.5 mm diameter and 13 and 15 mm length were placed in the incisal maxillary region. The median Periotest value 6 months post insertion was -2 with a minimum of -5 and a maximum of +2. The mean coronal bone level changes (CBD) at 6 and 12 months were 0.45 and 0.75 mm. No implant failed up to 12 months after insertion, resulting in a 100% survival rate. The presented results showed promising data for immediately loaded single-tooth implants in the anterior maxilla. Periotest values were within the range published for submerged implants. The radiographic coronal bone resorption after 6 and 12 months was even less than evaluated for implants placed in a standard two-stage procedure. It is evident that successful immediate loading protocols require a careful and strict patient selection aimed at achieving the best primary stability and avoiding any excessive functional or non-functional loading. Additional research needs to be done to provide data in situations where problems of poor bone quality, multiple implants or augmentation procedures must be overcome.

Acrylic Resins↗

Hardness measured with traditional Vickers and Martens hardness methods.

OBJECTIVE: To determine the differences, if any, between hardness measured with traditional Vickers and Martens hardness test methods on denture teeth under 2, 10 and 50 N loads. METHOD: Hardness of acrylic resin (VIV), composite resin (ORT) and porcelain (POR) denture tooth materials was measured using a traditional Vickers hardness (HV) method and Martens hardness (HM) method at 2, 10 and 50N test loads. Vickers hardness was also calculated from the force-indentation depth curves (HVfid) that were recorded during Martens hardness. Indentation creep of the three test materials was also determined during Martens hardness testing. RESULTS: HM values were the same irrespective of the test force used. However, HV values were different for the three test forces. ANOVA using Tukey's test of the HM data showed that the hardness of POR was significantly higher than VIV or ORT (P<0.001). Moreover, ORT had a significantly higher hardness than VIV (P<0.001). The statistical analysis of HVfid data showed similar results. ANOVA of the HV data showed the hardness of VIV to be significantly higher than ORT (P<0.001) under 2, 10 and 50 N test load. The HV values for POR under 2 and 10 N test load could not be calculated because of inability to measure the indentation diagonals. Under the 50 N load, the hardness of POR was significantly higher than VIV and ORT. POR had a significantly lower creep value than any other material tested while VIV showed a statistically significantly higher creep than ORT. SIGNIFICANCE: This study confirms that the visco-elastic recovery of the materials has a very significant effect on the outcome of the hardness tests of denture teeth and the Martens hardness test method has obvious advantages when testing dental materials.

Acrylic Resins↗

Effect of encapsulation of mefenamic acid with cationic Eudragit E on its bioavailability and gastric ulcerogenic activity in rabbits.

Encapsulation of mefenamic acid (MFA), a potent non-steroidal anti-inflammatory drug with cationic acrylic resin, Eudragit E, was carried out using a fluidized-bed granulator (Glatt AG). Three drug:polymer ratios were prepared using 50 ml of 1, 2.5 and 5 per cent w/v aqueous suspension of Eudragit to coat 100 mg powdered drug. The bioavailability of the coated and uncoated drug was studied using four groups of animals, each consisting of six male rabbits (2-2.5 kg). Investigations were performed using the rabbits to examine the effects of prolonged administration of the coated and the uncoated MFA with Eudragit E(1 and 5 per cent) in a dose of 100 mg filled in hard gelatin capsules. One capsule was given daily for 30 days. Plasma levels of MFA with Eudragit E were significantly higher than those of drug only. Meanwhile, 5 per cent w/v polymer coating afforded higher drug availability than 2.5 per cent w/v which induced a higher level than 1 per cent w/v. Chronic gastric ulcers with different severities were found in the internal mucosa of all animals. In addition, there were multiple erosions in the glandular mucosa of stomachs of rabbits receiving MFA within the treatment period. IN the control group the gastric photograph was normal in every instance. Despite the extensive morphological damage at the end of treatment, the observed changes in the stomach of rabbits given coated drug is less deleterious than that treated with uncoated drug. The results of this study indicate that the coating of MFA with cationic Eudragit E increases its bioavailability and decreases the probability of ulceration.(ABSTRACT TRUNCATED AT 250 WORDS)

Acrylic Resins↗

A short-term clinical evaluation of immediately restored maxillary TiOblast single-tooth implants.

PURPOSE: The purpose of this study was to evaluate the short-term clinical outcome of single-tooth implants placed in the maxilla and immediately restored using cementless friction-fit temporary crowns. MATERIALS AND METHODS: Twenty-five patients consecutively referred to a private specialist practice for the replacement of failing or missing maxillary teeth were treated by means of immediate temporization of their single-tooth implants. Where teeth were still present, implants were placed immediately following extraction. Provisional crowns were fabricated on a special friction-fit coping by means of autopolymerizing acrylic resin. Definitive crowns were placed a mean of 4.5 months after surgery. Implant survival was recorded along with the level of the marginal bone relative to a fixed reference point 1 year after placement. Any adverse soft tissue changes were also noted. RESULTS: A total of 28 Astra Tech ST dental implants were placed. The overall survival rate at the end of the study was 96.4% for implants which were in function for periods ranging from 15.7 to 27 months. One patient, a smoker, lost 1 implant within 1 month of surgery. Mean marginal bone loss was 0.40 mm (range 0 to 1.53 mm) 1 year after placement of the implants. Many implants (37.5%) had no observed bone loss. No implants or crowns have been lost during the functional loading period. One implant was associated with an unfavorable recession of soft tissues; however, most maintained an esthetic gingival architecture. Eleven of 28 provisional restorations needed treatment; 6 required replacement during the temporization period, and 5 required cementation because of looseness. The ease of removal of the crowns allowed regular access for irrigation with chlorhexidine and thus maintenance of soft tissue health. DISCUSSION: The need to provide provisional restorations for single-tooth gaps often presents challenges. An immediate temporary partial denture or adhesive prosthesis may be unacceptable or impractical. The current study describes a simple method for the immediate temporization of single-tooth implants. The results did not indicate any negative influence on osseointegration or short-term survival once the implants were functionally loaded. CONCLUSION: Immediate temporization of maxillary single-tooth implants can be both safe and predictable, and it appears that the procedure can yield favorable soft tissue esthetics.

Acrylic Resins↗

Monotonic flexure and fatigue strength of composites for provisional and definitive restorations.

STATEMENT OF PROBLEM: Ordinarily, the mechanical strength of composites is characterized by their flexural strength. Information as to the material's fatigue strength is seldom provided. PURPOSE: The purpose of this study was to compare the flexural strength and the resistance to fatigue loading of composites and an acrylic resin for provisional and definitive restorations. MATERIAL AND METHODS: Artglass, Colombus, and Targis (composites) and Jet, Protemp II, Protemp Garant, and Provipont DC (provisional restorations) were subjected to mechanical tests. Fatigue tests (MPa) (n = 30 specimens/group) were conducted with the rotating-bending cantilever design. Monotonic flexural strength (MPa) (n = 10) was determined in 3-point bending tests. Fatigue resistance was analyzed via the staircase procedure, and flexural strength was examined by use of the 2-parameter Weibull distribution (confidence intervals at 95%). RESULTS: The mean fatigue resistances (S(50)) in MPa +/- SD were: Targis, 62.1 +/- 7.0; Artglass, 58.5 +/- 3.7; Colombus, 54.6 +/- 6.2; Provipont DC, 29.5 +/- 3.2; Protemp II, 23.1 +/- 5.3; Jet, 22.8 +/- 8.3; Protemp Garant, 19.6 +/- 4.6. The flexure strengths (Weibull's S(0)) in MPa and their shape parameters (m) were: Colombus, 145.2 (13.1); Targis, 110.3 (7.8); Artglass, 5.9 (5.4); Jet, 150.9 (17.3); Provipont DC, 97.3 (23.8); Protemp II, 57.9 (6.4); Protemp Garant, 54.2 (12.8). The S(50) of Targis was significantly higher than that of Colombus but not different from Artglass. In flexion, the S(0) of Colombus was significantly higher than that of Artglass and Targis. The S(50) ranged between 40% and 60% of the S(0) for the composites and between 15% and 30% for the provisional restorative materials. CONCLUSIONS: Correlations between monotonic flexure strength and resistance to fatigue loading were weak. Because fatigue tests are considered more pertinent than monotonic tests as to their predictive value, it is concluded that flexure strength data alone may not provide relevant information for long-term clinical performance. The material's resistance to fatigue loading should also be determined.

Acrylic Resins↗

Influence of posts and cores on light transmission through different all-ceramic crowns: spectrophotometric and clinical evaluation.

PURPOSE: The influence of different types of posts and cores on light transmission through all-ceramic crowns was assessed by spectrophotometric analysis and clinical evaluation. MATERIALS AND METHODS: Three extracted natural teeth were replicated in acrylic resin, with roots prepared to receive standardized posts and cores. Using a silicone impression material as a template, various prosthodontic reconstructions were obtained by combining four types of posts and cores (polished and matte-finished gold alloy, all-ceramic, and ceramized metal alloy) and three types of all-ceramic crowns (IPS-Empress 2 surface-colored, IPS-Empress 2 stratified, and In-Ceram). The spectrophotometric analysis was performed in the dark at 25 degrees C. The teeth were backlit with an incandescent lamp at the color temperature of A illuminant and shielded to avoid spurious light entering the spectrophotometer. The transmitted light was analyzed in terms of luminance at four points of the sample surface (cervical, middle, incisal, and proximal). Twelve measurements were performed for the natural teeth, and 144 were performed for the artificial teeth. RESULTS: Natural teeth had the highest luminance. Among all-ceramic crowns, surface-colored IPS-Empress 2 had the highest luminance, and stratified IPS-Empress 2 had the lowest. Regarding posts and cores, the luminance was highest with the all ceramic, lower with the ceramized and the polished gold alloy (which had very similar luminance), and lowest with the matte-finished gold alloy. No significant difference among prosthodontic combinations was detected under clinical observation. CONCLUSION: The surface-colored glass ceramic (IPS-Empress 2) was the most translucent crown. At the standard crown thickness used, there were small, significant spectrophotometric, but not clinical, differences among the combinations tested. These findings show no esthetic contraindications for the use of polished gold alloy posts and cores with all-ceramic crowns.

Acrylic Resins↗