Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “VIBRATION”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91Linked to original sources

Responses of vibration-sensitive receptors in the interosseous region of the duck's hind limb.

1. Responses of receptors with fibres in the interosseous nerve of the duck's leg have been studied by recording unit discharges in filaments dissected from the sciatic nerve.2. Seventy-two of the ninety-four units examined served highly phasic, vibration-sensitive mechanoreceptors in the interosseous region interpreted as being Herbst corpuscles. Receptor types for most of the other units could not be determined, but some were slowly adapting mechanoreceptors.3. Rheobase threshold values for the most sensitive vibration-receptors were similar to those of mammalian Pacinian corpuscles.4. Threshold-frequency relationships for the vibration receptors showed a wider range of low frequency cut-off values, and a greater capacity to signal high frequencies, than is the case with Pacinian corpuscles.5. Fibres of the vibration-receptors had calculated diameters ranging from 5 to 10 mum and account for the bulk of the larger fibres in the interosseous nerve.6. It is suggested that Herbst corpuscles in the legs of birds might act as a warning device by detecting vibratory disturbances of the ground or other supporting surface.

Action Potentials↗

Assessment of the directional elastic moduli of ewe vertebral cancellous bone by vibrational testing.

The ovariectomized ewe is being used as an animal model for postmenopausal osteoporosis. Data on the mechanical properties of ewe vertebral cancellous bone is needed to assess its effectiveness as a model for vertebral osteoporosis. This study utilized traditional compression testing and a novel nondestructive vibrational testing method to assess the directional mechanical properties of ewe vertebral cancellous bone. Composition and density properties were also assessed. It was hypothesized that vibrational testing would have utility in that it would allow for the anisotropic stiffness of cancellous bone to be assessed nondestructively. The present study has found that ewe vertebral cancellous bone has similar physical and mechanical properties to humans. The vibrational testing method described was able to nondestructively provide a valid measure of stiffness that was correlated with stiffness estimates from traditional compression testing. Furthermore, the stiffness measure from the vibration test was found to be sensitive to the architecture of cancellous bone. These results suggest the promise of this testing method for the nondestructive mechanical assessment of skeletal tissue.

Animals↗

Dynamics of the head-neck complex in response to the trunk horizontal vibration: modeling and identification.

Although many studies exist concerning the influence of seat vibration on the head in the seated human body, the dynamic response of the head-neck complex (HNC) to the trunk vibration has not been well investigated. Little quantitative knowledge exists about viscoelastic parameters of the neck. In this study, the dynamics of the HNC is identified when it is exposed to the trunk horizontal (fore-and-aft) vibration. The frequency response functions between the HNC angular velocity and the trunk horizontal acceleration, corresponding to four volunteers, are obtained in the frequency range of 0.5 Hz to 10 Hz. A fourth-order mathematical model, derived by considering a double-inverted-pendulum model for the HNC, is designed to simulate the dynamic response of the HNC to the trunk horizontal vibration. The frequency domain identification method is used to determine the coefficients of the mathematical model of the HNC. Good agreement has been obtained between experimental and simulation results. This indicates that the system, similar to the designed fourth-order model, has mainly two resonance frequencies. The viscoelastic parameters of the neck, including the spring and damping coefficients, are then obtained by use of the optimization method.

Acceleration↗

Vibrational characteristics of bone fracture and fracture repair: application to excised rat femur.

BACKGROUND: The vibrational characteristics of any object are directly dependent on the physical properties of that object. Therefore, changing the physical properties of an object will cause the object to adopt changed natural frequencies. A fracture in a bone results in the loss of mechanical stability of the bone. This change in mechanical properties of a bone should result in a change of the resonant frequencies of that bone. A vibrational method for bone evaluation has been introduced. METHOD OF APPROACH: This method uses the radiation force of focused amplitude-modulated ultrasound to exert a vibrating force directly, and remotely, on a bone. The vibration frequency is varied in the range of interest to induce resonances in the bone. The resulting bone motion is recorded and the resonance frequencies are determined. Experiments are conducted on excised rat femurs and resonance frequencies of intact, fractured, and bonded (simulating healed) bones are measured. RESULTS: The experiments demonstrate that changes in the resonance frequency are indicative of bone fracture and healing, i.e., the fractured bone exhibits a lower resonance frequency than the intact bone, and the resonance frequency of the bonded bone approaches that of the intact bone. CONCLUSION: It is concluded that the proposed radiation force method may be used as a remote and noninvasive tool for monitoring bone fracture and healing process, and the use of focused ultrasound enables one to selectively evaluate individual bones.

Animals↗

Identification of in-vivo vibration modes of human tibiae by modal analysis.

When attempting to evaluate the mechanical properties of human bones in vivo by mechanical vibration analysis, some essential requirements must be met. A quantitative relation between measured vibration parameters (e.g., natural frequency) and mechanical bone properties must be available, in-vivo vibration modes should correctly be identified and the associated natural frequencies reproducibly and accurately measured, the influence of joints and soft tissues must be known. These problems were addressed by modal analysis (i.e., experimental determination of natural frequencies, mode shapes and damping ratios) of human tibiae in the following situations: 1) dry excised tibiae, 2) fresh excised tibiae, 3) in-vivo tibiae, 4) tibiae in an amputated leg, in different steps of dissection. In the in-vivo measuring conditions used by the authors, the tibia vibration is practically free-free. Two single bending modes (at +/- 270 Hz and +/- 340 Hz, respectively), each of them corresponding with one principal direction for bending, were identified. The difference between the natural frequencies observed in vivo and those of fresh excised tibiae is almost completely caused by the effect of muscles (added mass and damping), whereas joints and skin play only a minor role. Frequency differences between fresh and dry excised tibiae are largely accounted for by the absence of bone marrow in the latter.

Adult↗

Resonance properties of the vocal folds: in vivo laryngoscopic investigation of the externally excited laryngeal vibrations.

The study presents the first attempt to investigate resonance properties of the living vocal folds by means of laryngoscopy. Laryngeal vibrations were excited via a shaker placed on the neck of a male subject and observed by means of videostroboscopy and videokymography (VKG). When the vocal folds were tuned to the phonation frequency of 110 Hz and sinusoidal vibration with sweeping frequency (in the range 50-400 Hz) was delivered to the larynx, three clearly pronounced resonance peaks at frequencies around 110, 170, and 240 Hz were identified in the vocal fold tissues. Different modes of vibration of the vocal folds, observed as distinct lateral-medial oscillations with one, two, and three half-wavelengths along the glottal length, respectively, were associated with these resonance frequencies. At the external excitation frequencies below 100 Hz, vibrations of the ventricular folds, aryepiglottic folds and arytenoid cartilages were dominant in the larynx.

Adult↗

A bending wave simulator for investigating directional vibration sensing in insects.

Substrate vibrations are important in social and ecological interactions for many insects and other arthropods. Localization cues include time and amplitude differences among an array of vibration detectors. However, for small species these cues are greatly reduced, and localization mechanisms remain unclear. Here we describe a method of simulating the vibrational environment that facilitates investigation of localization mechanisms in small species. Our model species was the treehopper Umbonia crassicornis (Membracidae; length 1 cm), which communicates using bending waves that propagate along plant stems. We designed a simulator consisting of a length of dowel and two actuators. The actuators were driven with two time signals that created the relationship between slope and displacement characteristic of steady-state bending wave motion. Because the surface of the dowel does not bend, as would a natural stem, close approximation of bending wave motion was limited to a region in the center of the dowel. An example of measurements of the dynamic response of an insect on the simulator is provided to illustrate its utility in the study of directional vibration sensing in insects.

Animal Communication↗

Modeling of chaotic vibrations in symmetric vocal folds.

The chaos mechanism of above-range phonation was examined in symmetrically modeled vocal folds by using the traditional two-mass model assumption. The Poincaré map technique was used to display chaotic attractors. This method provided an effective description of irregular vocal-fold movements. The power spectrum, Lyapunov exponent, and Kaplan-Yorke dimension were employed to describe chaotic vibrations in the vocal-fold model. These nonlinear dynamic analyses suggested that, for the positive Lyapunov exponent, chaotic attractors contribute to irregular vocal-fold vibrations. Descriptions of complicated irregular vibrations of the vocal fold yielded evidence of chaos. To investigate the effects of independent parameters such as subglottal pressure, coupling stiffness, and phonation neutral area, bifurcation diagrams based on the Poincaré map were discussed. The results confirmed that the dynamics of the two-mass model was strongly influenced by independent parameters. Nonlinear dynamic methods were expected to provide useful information for better understanding of irregular vocal-fold vibrations as well as of the dynamic mechanism of above-range phonation in excised larynx experimentation.

Humans↗

Remote measurement of material properties from radiation force induced vibration of an embedded sphere.

A quantitative model is presented for a sphere vibrated by two ultrasound beams of frequency omega1 and omega2. Due to the interference of two sound beams, the radiation force has a dynamic component of frequency omega2-omega1. The radiation impedance and mechanical impedance of the sphere are then used to compute the vibration speed of the sphere. Vibration speed versus vibration frequency is measured by laser vibrometer on several spheres, both in water and in gel phantom. These experimental results are used to verify the model. This method can be used to estimate the material properties of the medium (e.g., shear modulus) surrounding the sphere.

Elasticity↗

Noncontact ultrasound stimulated optical vibrometry study of coupled vibration of arterial tubes in fluids.

Coupled vibration of arterial tubes is analyzed with the wave propagation approach and first-order shear deformation theory. Both the interior and exterior fluids are considered as compressible so that acoustic waves can be generated and propagated in the fluids. Results obtained using the theory have been evaluated against those available in the literature and the agreement has been found to be good. The theory can be used for future research on the vibration and acoustics of arterial walls. Vibration experiments were carried out on a silicone rubber tube in a water tank with a novel ultrasound stimulated optical vibrometry system. This system uses the radiation force of ultrasound to vibrate the tube at low frequency and records the resulting response by a laser vibrometer. Both the excitation and measurement are remote and noncontact. The silicone rubber tube was chosen because it has mechanical properties close to those of arteries. The fundamental frequency is well excited by the radiation force and measured with the laser. The measured fundamental frequency is in good agreement with the present theory.

Arteries↗

Model-based classification of nonstationary vocal fold vibrations.

Classification of vocal fold vibrations is an essential task of the objective assessment of voice disorders. For historical reasons, the conventional clinical examination of vocal fold vibrations is done during stationary, sustained phonation. However, the conclusions drawn from a stationary phonation are restricted to the observed steady-state vocal fold vibrations and cannot be generalized to voice mechanisms during running speech. This study addresses the approach of classifying real-time recordings of vocal fold oscillations during a nonstationary phonation paradigm in the form of a pitch raise. The classification is based on asymmetry measures derived from a time-dependent biomechanical two-mass model of the vocal folds which is adapted to observed vocal fold motion curves with an optimization procedure. After verification of the algorithm performance the method was applied to clinical problems. Recordings of ten subjects with normal voice and ten dysphonic subjects have been evaluated during stationary as well as nonstationary phonation. In the case of nonstationary phonation the model-based classification into "normal" and "dysphonic" succeeds in all cases, while it fails in the case of sustained phonation. The nonstationary vocal fold vibrations contain additional information about vocal fold irregularities, which are needed for an objective interpretation and classification of voice disorders.

Adult↗

Vibration and sound signatures of human footsteps in buildings.

The acoustic signature of a footstep is one of several signatures that can be exploited for human recognition. Early research showed the maximum value for the force of multiple footsteps to be in the frequency band of 1-4 Hz. This paper reports on the broadband frequency-dependent vibrations and sound pressure responses of human footsteps in buildings. Past studies have shown that the low-frequency band (below 500 Hz) is well known in the literature, and generated by the force normal to the ground/floor. The seismic particle velocity response to footsteps was shown to be site specific and the characteristic frequency band was 20-90 Hz. In this paper, the high-frequency band (above 500 Hz) is investigated. The high-frequency band of the vibration and sound of a human footstep is shown to be generated by the tangential force to the floor and the floor reaction, or friction force. The vibration signals, as a function of floor coverings and walking style, were studied in a broadband frequency range. Different walking styles result in different vibration signatures in the low-frequency range. However, for the walking styles tested, the magnitudes in the high-frequency range are comparable and independent of walking style.

Female↗

Anterior-posterior biphonation in a finite element model of vocal fold vibration.

In this paper, a finite-element model is used to simulate anterior-posterior biphonation [Neubauer et al., J. Acoust. Soc. Am. 110(6), 3179-3192 (2001)]. The anterior-posterior stiffness asymmetric factor and the anterior-posterior shape asymmetric factor describe the asymmetry properties of vocal folds. Spatiotemporal plot, spectral analysis, anterior-posterior fundamental frequency ratio, cross covariation function, and correlation length quantitatively estimate the spatial asymmetry of vocal fold oscillations. Calculation results show that the anterior-posterior stiffness asymmetry decreases the spatial coherence of vocal fold vibration. When the stiffness asymmetry reaches a certain level, the drop in spatial coherence desynchronizes the vibration modes. The anterior and posterior sides of the vocal fold oscillate with two independent fundamental frequencies (f(a) and f(p)). The complex spectral characteristics of vocal fold vibration under biphonation conditions can be explained by the linear combination of f(a) and f(p). Empirical orthogonal eigenfunctions prove the existence of higher-order anterior-posterior modes when anterior-posterior biphonation occurs. Then, it is found that the anterior-posterior shape asymmetry also decreases the spatial coherence of vocal fold vibration, and shape asymmetry is a possible reason for anterior-posterior biphonation.

Humans↗

Mechanisms of irregular vibration in a physical model of the vocal folds.

Previous investigations have shown that one mechanism of irregular vocal fold vibration may be a desynchronization of two or more vibratory modes of the vocal fold tissues. In the current investigation, mechanisms of irregular vibration were further examined using a self-oscillating, physical model of vocal fold vibration, a hemi-model methodology, and high-speed, stereoscopic, digital imaging. Using the method of empirical eigen-functions, a spatiotemporal analysis revealed mechanisms of irregular vibration in subharmonic phonation and biphonation, which were not disclosed in a standard acoustic spectrum.

Acoustics↗

Noise and vibration interactions: effects on hearing.

There is the suggestion in the literature that vibration may potentiate the effects of noise and may thus increase the risk of hearing loss in a variety of exposure situations. However, in human experimental studies, which, by necessity, are limited to low levels of exposure, the effects measured are relatively small. A very limited number of animal studies have also shown an enhanced noise-induced hearing loss in the presence of vibration, but the scope of these studies is limited. The animal studies (chinchilla) that form the basis of this report were performed using a 30-Hz, 3g rms and a 20-Hz, 1.3g rms cage vibration separately and in combination with continuous noise (95-dB, 0.5-kHz octave band) and impact noise (113, 119, or 125 dB peak SPL) exposure paradigms. All exposures lasted for 5 days. The impact noise exposures were designed to have approximately equal total energy. Temporary and permanent threshold shifts were measured using evoked potentials, and sensory cell loss was measured using surface preparation histology. The results obtained from some of the noise/vibration paradigms showed that such exposures can alter some of the dependent measures of hearing. This effect was statistically significant only for the stronger vibration exposure conditions and was evident primarily in the extent of the outer hair cell losses and in the shape of the PTS audiogram.

Animals↗

Vibration-induced postural reaction continues after the contact with additional back support.

We investigated the development of postural reactions induced in standing subjects by Achilles tendon vibration. We compared vibratory reactions in 3 different conditions: normal standing, standing near support, and when the solid support being protracted forward changed the initial posture. Additional support for the back was placed at subject's sacral or shoulder level. In the easy standing condition, the postural vibration reaction consists of progressive backward upper body movement. When the body contacted the additional support on the sacral level during the vibratory reaction, the movement of the upper body continued in most of the subjects. This was accompanied by an increase of pressure on the toes. When the support was applied at the shoulder level, the body motion reversed its direction in half of the subjects. In this case, backward-forward oscillations occurred near the support. The initial change of body-support interaction did not influence the ensuing vibration reaction; namely the reaction was similar to that with the support near to the body at the sacral level. Our data demonstrate that the vibration-induced reaction is not a local reaction limited to one joint, but a complex postural synergy that involves both leg and trunk muscles and integrates the information from touch and pressure afferents of the upper body.

Achilles Tendon↗

White blood cell activation in Raynaud's phenomenon of systemic sclerosis and vibration induced white finger syndrome.

Systemic sclerosis (SSc) and vibration induced white finger syndrome (VWF) are common causes of secondary Raynaud's phenomenon. Previous studies have suggested an increase in inflammation in patients with SSc. Vibration induced white finger syndrome occurs in workers exposed to vibration and is now a prescribed disease. In VWF, although it is recognised that vibration can cause direct damage to blood vessels, it does not explain why only some workers are affected. It is possible that an inflammatory process develops in these patients in the same way as is seen in SSc. Leukotriene B4, produced mainly by polymorphonuclear cells, is a potent mediator of inflammation. The plasma thiol concentration shows the degree of oxidation of plasma and a decreased concentration indicates the increased production of free radicals which are capable of oxidative damage. In this work, the white blood cell (WBC) production of leukotriene B4 and plasma thiol concentrations were measured in patients with SSc and VWF. Fifty nine patients were studied: 34 had SSc and 25 had VWF. The results were compared with 25 matched normal controls and are expressed as the median and range. After stimulation of the polymorphonuclear cells with calcium ionophore A23187 (1 microgram/ml), patients with SSc and VWF were found to have significantly increased leukotriene B4 production (23.5 (14.4-44.0) and 26 (14.4-39.4) ng/10(6) cells, respectively) compared with normal controls (17.2 (6.0-38.0) ng/10(6) cells). The plasma thiol concentration was shown to be significantly lower in patients with SSc and VWF (445 (375-475) and 450 (417-510) mumol/l, respectively) compared with normal controls (480 (418-555) mumol/l). Our results show increased leukotriene B4 production and increased free radical activity in patients with SSc and VWF. Although previous indirect evidence has suggested increased WBC activity in patients with SSc, this is reported directly here for the first time. In addition, the possibility of an inflammatory process occurring in patients with VWF, as shown here, has not previously been studied. This may be a further mechanism to explain the poor circulation in the fingers of these patients.

Adult↗

Influence of vibration on delayed onset of muscle soreness following eccentric exercise.

UNLABELLED: Delayed onset muscle soreness (DOMS), which may occur after eccentric exercise, may cause some reduction in ability in sport activities. For this reason, several studies have been designed on preventing and controlling DOMS. As vibration training (VT) may improve muscle performance, we designed this study to investigate the effect of VT on controlling and preventing DOMS after eccentric exercise. METHODS: Fifty healthy non-athletic volunteers were assigned randomly into two experimental, VT (n = 25) and non-VT (n = 25) groups. A vibrator was used to apply 50 Hz vibration on the left and right quadriceps, hamstring and calf muscles for 1 min in the VT group, while no vibration was applied in the non-VT group. Then, both groups walked downhill on a 10 degrees declined treadmill at a speed of 4 km/hour. The measurements included the isometric maximum voluntary contraction force (IMVC) of left and right quadriceps muscles, pressure pain threshold (PPT) 5, 10 and 15 cm above the patella and mid-line of the calf muscles of both lower limbs before and the day after treadmill walking. After 24 hours, the serum levels of creatine-kinase (CK), and DOMS level by visual analogue scale were measured. RESULTS: The results showed decreased IMVC force (P = 0.006), reduced PPT (P = 0.0001) and significantly increased mean of DOMS and CK levels in the non-VT group, compared to the VT group (P = 0.001). CONCLUSION: A comparison by experimental groups indicates that VT before eccentric exercise may prevent and control DOMS. Further studies should be undertaken to ascertain the stability and effectiveness of VT in athletics.

Adult↗