Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Solid Phase Extraction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91Linked to original sources

Solid-phase extraction and large-volume sample stacking with an electroosmotic flow pump in capillary electrophoresis for determination of methotrexate and its metabolites in human plasma.

This paper describes approaches for large-volume sample stacking (LVSS) with an EOF pumpin CE for the determination of methotrexate (MTX) and its metabolites in human plasma. After pretreatment of plasma through a SPE cartridge, a large sample volume was loaded by hydrodynamic injection (3 psi, 70 s) into the capillary filled with phosphate buffer (70 mM, pH 6.0) containing 0.01% polyethylene oxide. Following removal of a large plug of sample matrix from the capillary using polarity switching (-25 kV), the separation of anionic analytes was subsequently performed without changing polarity again, achieving an improvement of sensitivity of around a 100-fold. The method was applied to therapeutic drug monitoring of MTX in one acute lymphoblastic leukemia patient. This study is one of very few applications showing the feasibility of LVSS in analysis of biological samples by CE.

Antimetabolites, Antineoplastic↗

Determination of tobacco-specific N-nitrosamines in rabbit serum by capillary zone electrophoresis and capillary electrophoresis-electrospray ionization-mass spectrometry with solid-phase extraction.

In this paper, we propose a new strategy for separation and determination of tobacco-specific N-nitrosamines (TSNAs), a group of strong carcinogens found only in tobacco products, by using CZE and CE-MS associated with SPE. Six TSNAs: N'-nitrosonornicotine, N'-nitrosoanatabine, N'-nitrosoanabasine, 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone, 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol, and 4-(methylnitrosamino)-4-(3-pyridyl)-1-butanol were simultaneously separated by either of two CZE methods, one of which worked with ammonium formate buffer (pH 2.5) and another with citrate buffer (pH 2.4), as well as a CE-MS method. The CZE conditions including pH and concentration of running buffer, capillary length, applied voltage, and capillary temperature were systematically optimized. For CE-MS method, an optimized sheath liquid consisted of methanol-water was used at a flow rate of 10 muL/min. With SPE procedure, our proposed CE-MS method was successfully applied to determine TSNAs after 15 min metabolism in rabbits. A comparison study between CZE and CE-MS methods for quantitative purposes was carried out, showing that both methods provided similar separation efficiency, selectivity, repeatability, linearity, and recovery. However, CE-MS method was better suited for the analysis of TSNAs in complicated biological samples for its sensitivity and extra information on molecular structure. Having good accordance with our previous work by using LC-MS, the new CE-MS method is expected to be an alternative to the LC-MS method and applied to study the metabolism of TSNAs.

Animals↗

External-standard high-performance liquid chromatographic method for quantitative determination of furosemide in plasma by using solid-phase extraction and on-line elution.

A rapid and simple external-standard high-performance liquid chromatographic (HPLC) method has been developed for the determination of the concentration of furosemide in plasma. The analyte is extracted with a C-2 ethyl sorbent. On-line elution of the analyte into the HPLC system is accomplished with an advanced automated sample processor (Varian). Furosemide is quantified by fluorescence detection within a linear range of 25 to 1000 ng/mL (average correlation coefficient, 0.9998), with a limit of detection of 1.8 ng/mL. Both internal- and external-standard procedures were evaluated, and the external-standard procedure demonstrated superior characteristics. The external-standard procedure was precise to within a relative standard deviation of 8% and accurate with less than 3% error throughout the concentration range studied. The external-standard HPLC method was used to analyze the concentration of furosemide in greater than 1000 plasma samples obtained from patients with either normal kidney function or renal failure who had received furosemide either orally or intravenously in an experimental setting.

Aged↗

Development of a validated HPLC method for the determination of B-complex vitamins in pharmaceuticals and biological fluids after solid phase extraction.

An HPLC method was developed for the simultaneous determination of seven water-soluble vitamins, viz. thiamine, riboflavin, nicotinic acid, nicotinamide, pyridoxine, cyanocobalamin, and folic acid, in multivitamin pharmaceutical formulations and biological fluids (blood serum and urine). Separation was achieved at ambient temperature on a Phenomenex Luna C18 (150 x 4.6 mm) analytical column. Gradient elution was performed starting at a 99:1 A:B v/v composition, where A: 0.05 M CH3COONH4/CH3OH (99/1) and B: H2O/CH3OH (50/50), at a flow rate of 0.8 mL/min. After a 4-min isocratic elution the composition was changed to 100% of B in 18 min and elution continued isocratically for 8 min. Detection was performed with a photodiode array detector at 280 nm. Each vitamin was quantitatively determined at its maximum wavelength. Spectral comparison was used for peak identification in real samples. Detection limits were in the range of 1.6-3.4 ng, per 20-microL injection, while linearity held up to 25 ng/microL. Accuracy, intra-day repeatability (n = 6), and inter-day precision (n = 7) were found to be satisfactory. Theobromine (2 ng/microL) was used as internal standard. Sample preparation of biological fluids was performed by SPE on Supelclean LC-18 cartridges with methanol-water 85/15 v/v as eluent. Extraction recoveries from biological matrices ranged from 84.6% to 103.0%.

Chromatography, High Pressure Liquid↗

Thioacetamide chemically immobilized on silica gel as a solid phase extractant for the extraction and preconcentration of copper(II), lead(II), and cadmium(II).

Thioacetamide immobilized on silica gel was prepared via the Mannich reaction. The extraction and enrichment of copper(II), lead(II), and cadmium(II) ions from aqueous solutions has been investigated. Conditions for effective extraction are optimized with respect to different experimental parameters in both batch and column processes prior to their determination by flame atomic absorption spectrometry (FAAS). The optimum pH ranges for quantitative adsorption are 4.0-8.0, 2.0-7.0, and 5.0-10.0 for Pb(II), Cu(II), and Cd(II), respectively. Pb(II) and Cd(II) can be desorbed with 3 mol/L and 0.1 mol/L HCl/HNO3, and Cu(II) can be desorbed with 2.5% thiourea. The adsorption capacity of the matrix has been found to be 19.76, 16.35, and 12.50 mg/g for Pb(II), Cu(II), and Cd(II), respectively, with the preconcentration factor of approximately equal to 300 for Pb(II) and approximately equal to 200 for Cu(II) and Cd(II). Analytical utility is illustrated in real aqueous samples generated from distilled water, tap water, and river water samples.

Journal Article↗

Selective enrichment of anti-inflammatory drugs from river water samples by solid-phase extraction with a molecularly imprinted polymer.

A molecularly imprinted polymer (MIP) is synthesised by a noncovalent protocol in which ibuprofen was used as a template molecule. The polymer was evaluated chromatographically and it was seen that the MIP showed cross-reactivity. Subsequently, when this polymer was used as sorbent in SPE it was possible to selectively extract a mixture of nonsteroidal anti-inflammatory drugs from aqueous samples when a cleanup step with dichloromethane was performed. The performance of the MIP was evaluated with river water and water from a wastewater treatment plant, and compared with the performance of a commercial Isolute ENV+ sorbent.

Anti-Inflammatory Agents↗

Ultratraces analysis of organochlorine pesticides in drinking water by solid phase extraction coupled with large volume injection/gas chromatography/mass spectrometry.

This study describes an SPE coupled with large volume injection (LVI) analytical method for the analysis of organochlorine pesticides, BHC (alpha, beta, delta), aldrin, endosulfan (alpha, beta), endrin, dieldrin, and DDT, from aqueous samples. Determination was carried out by GC with MS. The LODs of organochlorine pesticides were determined at 10 ng/L concentration levels, and the results show that SPE-LVI-GC/MS has the potential to accurately determine organochlorine pesticides in water, as it avoids analyte classes in the various steps of a typical extraction procedure.

Chromatography, Gas↗

Application of multiwalled carbon nanotubes as solid phase extraction sorbent for preconcentration of trace copper in water samples.

The adsorption behavior of multiwalled carbon nanotubes (MWNTs) toward copper has been investigated systemically, and a new method has been developed for the determination of trace copper in water samples based on preconcentration with a microcolumn packed with MWNTs prior to its determination by flame atomic absorption spectrometry. The optimum experimental parameters for preconcentration of copper, such as pH of the sample, sample flow rate and volume, elution solution and interfering ions, have been investigated. Copper can be quantitatively retained by MWNTs in the pH range 5-8, and then eluted completely with 0.5 M HNO3. The detection limit of this method for Cu was 0.42 ng/mL, and the RSD was 3.5% at the 10 ng/mL Cu level. The method was validated using a certified reference material, and has been successfully applied for the determination of trace copper in water samples.

Adsorption↗

Direct determination of ciprofloxacin by mass spectrometry after a two-step solid-phase extraction using a molecularly imprinted polymer.

A molecularly imprinted polymer (MIP) has been prepared for the first time with ciprofloxacin (CIPRO) as the template molecule, via a noncovalent synthetic procedure. Prior to its use as a sorbent in SPE, the MIP was evaluated chromatographically to confirm that it was indeed molecularly imprinted. The MIP was then used to extract CIPRO selectively from urine samples by means of a two-step SPE procedure in which a commercial Oasis cartridge and a molecularly imprinted SPE cartridge were combined in series. This approach allowed the matrix compounds present in the samples to be removed effectively. The urine extracts obtained after this two-step SPE procedure was applied were relatively clean compared to the original samples, and this made it possible to inject directly the extracts into a mass spectrometer and thus quantify CIPRO in urine samples at low levels and reduce the time of analysis.

Evaluation Study↗

A method for routine quantitation of urinary 8-hydroxy-2'-deoxyguanosine based on solid-phase extraction and micro-high-performance liquid chromatography/electrospray ionization tandem mass spectrometry.

8-Hydroxy-2'-deoxyguanosine (8OHdG), one of the major oxidative DNA lesions induced by radical agents, is commonly used as a biomarker for oxidative stress, nowadays preferably in urine. In the absence of a commercially available internal standard a micro-high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (micro-HPLC/ESI-MS/MS) method, suitable for routine analysis of 8OHdG in human urine using external calibration, was developed. Evaluation of the matrix effect showed that the method allows highly sensitive and accurate quantitation despite the absence of an internal standard. HPLC analysis was performed using gradient elution at a flow rate of 10 microL min(-1) using a capillary reversed-phase column and an injection volume of 0.5 microL, with detection of 8OHdG in positive multiple reaction monitoring (MRM) mode. The absolute limit of detection was 0.35 fmol using m/z 168 as a quantifier (fragment) ion. A linear (R2> 0.999) calibration curve in urine was obtained over a range 0.2-10 ng mL(-1). This method is about 20 times more sensitive than previously described procedures, and is characterized by high accuracy (mean 90%) and good reproducibility (RSD <10%). The optimized method was applied to determination of 8OHdG in 18 urinary samples derived from three healthy volunteers. 8OHdG urinary excretion ranged from 3.0-7.9 microg/day, and a large intra-individual variation was found. This method, which effectively circumvents the need for isotopically labeled 8OHdG (internal standard), is suitable for routine monitoring of exposure to DNA-damaging factors in a large number of subjects.

8-Hydroxy-2'-Deoxyguanosine↗

Simultaneous determination of ten antihistamine drugs in human plasma using pipette tip solid-phase extraction and gas chromatography/mass spectrometry.

Ten antihistamine drugs, diphenhydramine, orphenadrine, chlorpheniramine, diphenylpyraline, triprolidine, promethazine, homochlorcyclizine, cyproheptadine, cloperastine and clemastine, have been found to be extractable from human plasma samples using MonoTip C18 tips, inside which C18- bonded monolithic silica gel was fixed. Human plasma (0.1 mL) containing the ten antihistamines was mixed with 0.4 mL of distilled water and 25 microL of a 1 M potassium phosphate buffer (pH 8.0). After centrifugation of the mixture, the supernatant fraction was extracted to the C18 phase of the tip by 25 repeated aspirating/dispensing cycles using a manual micropipettor. The analytes retained on the C18 phase were then eluted with methanol by five repeated aspirating/dispensing cycles. The eluate was injected into a gas chromatography (GC) injector without evaporation and reconstitution steps, and was detected by a mass spectrometer with selected ion monitoring in the positive-ion electron impact mode. The separation of the ten drugs from each other and from impurities was generally satisfactory using a DB-1MS column (30 m x 0.32 mm i.d., film thickness 0.25 microm). The recoveries of the ten antihistamines spiked into plasma were 73.8-105%. The regression equations for the ten antihistamines showed excellent linearity with detection limits of 0.02-5.0 ng/0.1 mL. The within-day and day-to-day coefficients of variation for plasma were not greater than 9.9%. The data obtained from determination of diphenhydramine and chlorpheniramine in human plasma after oral administration of the drugs are also presented.

Administration, Oral↗

Evaluation of several solid phase extraction liquid chromatography/tandem mass spectrometry on-line configurations for high-throughput analysis of acidic and basic drugs in rat plasma.

Several configurations using 6- and 10-port switching valves were studied for high flow, on-line extraction of rat plasma coupled to an electrospray triple quadrupole mass spectrometer. Each plasma sample was diluted 1:1 with an aqueous internal standard solution. The sample was injected into a 2.1 x 20 mm cartridge column packed with 25 microm divinylbenzene/N-vinylpyrrolidone packing using 100% aqueous mobile phase at 4 mL/min. After sample loading and sample cleanup, the analytes were eluted from the extraction column with a 1.0-min gradient at 0.4 mL/min. The samples were either analyzed directly after elution from the extraction column or after additional separation using a short high performance liquid chromatography (HPLC) column. The different configurations were tested using an acidic drug (diflunisal) and a basic drug (clemastine) in rat plasma. On-line analysis was performed by injecting 200 microL of diluted plasma. The mass spectrometer was operated in the multiple reaction monitoring (MRM) mode. All calibration standards gave relative standard deviations (RSDs) below 5%. The total time per sample was 3 min.

Animals↗

Analysis of a basic drug by on-line solid-phase extraction liquid chromatography/tandem mass spectrometry using a mixed mode sorbent.

Two on-line configurations using multiple 6- and 10-port valves were investigated for high-flow on-line extraction of a basic drug in rat plasma and human urine using a reversed-phase and a cation-exchange SPE sorbent. The first configuration studied was a single reversed-phase extraction cartridge (2.1 x 20 mm, 25 microm) using an optimized washing protocol. The results showed that up to 1.5 mL of sample (urine or plasma diluted 1:1) can be injected with limits of quantification (LOQs) as low as 100 pg/mL. The second configuration studied was the combination of a cation exchanger and a reversed-phase cartridge using at-column dilution. The results showed better LOQs than those obtained with the single cartridge at 10 pg/mL with the same injection volume. The mass spectrometer was operated in the multiple reaction monitoring (MRM) mode. All calibration curves gave an average of 5% relative standard deviation (RSD).

Absorption↗