Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “MAMMOGRAPHY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91Linked to original sources

3D-MR mammography-guided breast conserving surgery after neoadjuvant chemotherapy: clinical results and future perspectives with reference to FDG-PET.

BACKGROUND: Three dimensional MR Mammography (3D-MRM) can detect tumor extension more accurately than mammography or ultrasound. There are two shrinkage patterns observed by 3D-MRM after neoadjuvant chemotherapy. Concentric shrinkage is a good indication for breast conserving surgery. On the other hand, a dendritic pattern was represent ductal spread. Therefore, we developed MRM guided mapping to aid BCS for tumors showing a dendritic pattern. METHODS: Fifteen patients consisting of 8 stage II (T > 3.5 cm) cases and 7 stage IIIa cases aged 39 to 61 years (mean 47-8 years) were treated with AT neoadjuvant chemotherapy with the aim of performing breast conserving surgery. All patients were examined by 3D-MRM before and after neoadjuvant chemotherapy. Breast conserving surgery indications were determined by tumor volume reduction and shrinkage patterns on 3D-MRM. Supine position mapping using MRM was performed for dendritic type tumors. FDG-PET was simultaneously performed for one case with bilateral breast cancer. RESULTS: Breast conserving surgery was performed for 13 of the 15 cases. One case underwent re-operating and mastectomy because of a positive margin. One case had microscopically positive margin and received boost radiation. Therefore, 11 of 15 cases (73.3%) underwent BCS and achieved negative margins under MRM guidance. PET scanning can detect residual tumor and occult metastasis but it is not suitable for mapping because of its spatial resolution. CONCLUSIONS: 3D-MRM is a useful modality to select appropriate cases for breast conserving surgery after neoadjuvant chemotherapy. FDG-PET can also detect residual tumor or occult metastasis but it may not be suitable for mapping. Because both examinations have potential, further evaluation of their clinical efficacy is necessary.

Adult↗

Efficacy of 3D-MR mammography for breast conserving surgery after neoadjuvant chemotherapy.

BACKGROUND: One of the main roles of neoadjuvant chemotherapy for breast cancer is to shrink large tumors to increase patient eligibility for breast conserving surgery. Three dimensional MR Mammography (3D-MRM) can detect tumor extension more accurately compared with mammography and Ultrasonography (US). Therefore, the shrinkage pattern observed on 3D-MRM was analyzed with regard to several pathological factors. METHODS: A total of 27 breast cancer cases were examined by 3D-MRM before and after neoadjuvant chemotherapy. The volume reduction and shrinkage patterns were assessed and compared with the pathological diagnosis. RESULTS: There were two shrinkage patterns. Twelve of 25 evaluable breast cancers (48%) showed a concentric shrinkage pattern while 13 cases (52%) showed a dendritic shrinkage pattern. The cases with concentric shrinkage were good candidates for breast conserving surgery, But tumors showing dendritic shrinkage often had positive margins necessitating mastectomy. Pathologically, tumors with a papillotubular pattern, Estrogen receptor (ER) positivity, low nuclear grade and c-erbB 2 negativity tended to show dendritic shrinkage. CONCLUSIONS: 3D-MRM is a useful modality for evaluating whether breast conserving surgery can be safely done in the neoadjuvant setting.

Antineoplastic Combined Chemotherapy Protocols↗

Evaluation of dynamic studies of MR mammography for the diagnosis of intraductal lesions with nipple discharge.

OBJECTIVES: We assessed the utility of dynamic magnetic resonance imaging (MRI) in differentiating benign from malignant lesions of the breast and then applied MRI to diagnose intraductal breast tumors with nipple discharge. METHODS: Gadolinium (Gd)-enhanced MR mammography was performed on 74 patients with breast tumors and 8 patients with nipple discharge. RESULTS: The steepest slopes of the contrast medium uptake (S slope) s from time-intensity curves were significantly different between malignant and benign lesions. At S slope threshold of 0.95% /second, malignancy was predicted with a sensitivity and specificity of 75% . Six of 8 cases with nipple discharge were successfully identified by MR ductography by injecting Gd-DTPA into discharging ducts. Among them, 2 non-invasive ductal carcinomas were differentiated from benign lesions by the S slope value. CONCLUSIONS: Dynamic MR mammography is an useful modality for differentiating breast lesions and has potential for evaluating intraductal lesions with nipple discharge.

Adult↗

Mammography.

A comparison is made of breast cancer mortality in women included in a mammography screening program, including those who refused to attend, and women who were not included--even those who underwent voluntary mammography. About 215,000 women in five different studies showed between 4 and 24% reduction of mortality; however, this was significant in only two of the studies. No significant reduction was seen in those under 50 yr of age.

Age Factors↗

Evaluation of digital mammography in diagnosis of breast cancer.

Mammography has been digitized in all cases at our hospital. Digital mammography (MMG) of our hospital and its diagnostic accuracy were described in this report. Fuji Computed Radiography (FCR; Fuji Medical Systems, Tokyo, Japan) imaging plate was used and imaging data were processed with FCR 7000 or FCR 9000. Each image was output to a single hard copy. Sampling pitches for reading and output were 0.1 mm. The rate of breast cancer diagnosis by digital MMG was 67%, 95%, 94%, and 100% for unpalpable tumor, tumor less than phi 2 cm, tumor of phi 2 to 5 cm, and tumor greater than phi 5 cm, respectively, being 94% overall. Digital MMG enables us to establish goal-oriented image-processing conditions. The use of digital MMG, which provides an excellent diagnostic rate similar to that of screen-film MMG, is expected to became wide-spread in the near future.

Breast Neoplasms↗

Advanced digital mammography.

Mammography is the most effective method for early detection of breast cancer and yet, 10% to 30% of women who have breast cancer and undergo mammography have negative mammograms. Furthermore, of the women who are sent to biopsy, only 20% to 40% actually have breast cancer. Quantitative analysis of the radiographic features of microcalcifications and masses may help radiologists improve their specificity.

Breast Neoplasms↗

A controlled evaluation of tuned-aperture computed tomography applied to digital spot mammography.

The purpose of this work was to compare the detection accuracy of 3-dimensional (3D) modalities of tuned-aperture computed tomography (TACT) with that of conventional 2-dimensional (2D) digital spot mammograms. A standardized mammographic phantom was placed beneath cadaveric breast tissues of varying densities. Five radiologists were asked to detect as many objects (specks, fibers, and low-contrast masses) as possible from 90 displays in a controlled and factorially balanced multivariate experiment. Radiographic exposure was varied systematically, and projections were averaged to ensure stochastic comparability. Scores were weighted to eliminate task-specific bias and were analyzed by multivariate analyses of variance. All display modalities based on the linear application of the 3D TACT reconstruction method yielded significantly higher detection scores for all tasks than did conventional 2D digital spot mammography, which served as the scientific control modality. This effect was found to be statistically significant (P < .001) in spite of significant variations between tissues (P < .001), observers (P < .001), and exposures (P < .01). TACT may be a promising alternative or enhancement to conventional 2D digital mammography for tasks well simulated by this experimental design.

Artifacts↗

Iterative interim techniques for reduced costs and a better mammography workstation: an opinion.

The promise of digital mammography has focused considerable resources on the challenges of mammography workstations, but the risk of wasted time and resources in such efforts is very high. Although final testing of the workstation's image quality and ergonomics is common, a number of interim evaluation and refinement techniques can be applied throughout the design and development process. The use of such techniques holds potential not only to save time and money but also to produce a superior workstation.

Cost-Benefit Analysis↗

Advanced digital mammography.

Mammography is the most effective method for early detection of breast cancer and yet, 10% to 30% of women who have breast cancer and undergo mammography have negative mammograms. Furthermore, of the women who are sent to biopsy, only 20% to 40% actually have breast cancer. Quantitative analysis of the radiographic features of microcalcifications and masses may help radiologists improve their specificity.

Breast Neoplasms↗

[Information on mammography screening--from deception to insight].

Information about mammography-screening as a basis for informed-decision making has to be evidence-based and presented in an unbiased format. This includes communication of results about effectiveness/lack of effectiveness of screening programmes (breast cancer mortality, total mortality), the quality of mammography as a screening test (sensitivity, specificity, positive and negative predictive values), and possible harm (consequences of false positive and false negative results, overdiagnosis of breast cancer, overtreatment). Outcome data have to be communicated as natural frequencies rather than relative differences. In order to avoid framing of data equal emphasis has to be put on the proportion of persons who are likely to benefit and those who are unlikely to benefit or likely to be harmed.

Breast Neoplasms↗

[Experience with a quality control system for mammography in a private practice setting].

Design and performance of a private audit of mammography utilizing the BI-RADS classification in a private practice setting are presented. By using a combination of physical examination,mammography and, whenever necessary, additional views and sonography, the goals of the BI-RADS audit were met. Practical issues of this audit are addressed.

Breast Neoplasms↗

[Multiple reader analysis for evaluation of functional MR mammography].

The diagnostic impact and reproducibility of the different methods used within the concept of functional MR-Mammography (FMRM) was assessed by a multi-reader-analysis. By four experienced readers, 100 histologically confirmed cases were evaluated in six different sessions. Per session, one of the following components was analyzed: clinical history (I), static MRM (II), color-coded projection images (III), time-signal curves of contrast enhancement within a large ROI (IV) and the strongest enhancing pixel (V) obtained from the histologically confirmed lesion and the complete FMRM reading (VI). The functional methods (IV-VI) revealed significantly (p < 0.05) higher specificities than the others (I-III). The highest reproducibility between the readers was observed for (IV) phi chi = 0.80, (V) phi chi = 0.76 and FMRM (VI) phi chi = 0.63. These three methods also presented the best ROC-curves and showed the highest complementarity with respect to the false positive classifications in x-ray mammography. FMRM is a reader independent, reproducible method. The analysis of the contrast enhancement time-intensity curves with high temporal resolution allows an improved differentiation of malignant and benign findings.

Adult↗

[Concept and implementation of model projects for mammography screening in Germany].

The carriers of the German Statutory Health Care System have recognized that only mammographic screening according to the European Guidelines for the Quality Assurance of Mammography Screening will permit early detection of breast cancer with an acceptable risk/benefit ratio. In the German pilot projects, regional mammography screening programmes according to the European guidelines are being tested in the framework of the German health care system. The European guidelines require comprehensive quality assurance of all relevant steps in the chain of events involved in screening, from invitation on to therapy and follow-up. Such comprehensive quality assurance involves several medical specialities and other professional groups dealing with out-patient and in-patient health care and requires long-term cooperation with public institutions (population registries, cancer registries). The objective of the pilot projects is to test the organizational and legal conditions essential to introduction of a mammographic screening programme according to the European quality assurance guidelines in Germany.

Breast Neoplasms↗

[Evaluation of current mammography screening studies in Europe and North America].

The ancient randomized-controlled trials of breast cancer screening have offered clear evidence that invitation to participate in mammography screening with/without clinical examination is effective in breast cancer mortality reduction und underline the detection sensitivity of mammography. Recently published criticism of both the effect and fundamental data handling could be shown to be untenable. Randomized studies underestimate the effect while well-designed observational studies do not systematically overestimate the magnitude of the effect. To transform high-quality study results in all-day's practice is a hugh challenge, but affordable as has been demonstrated in Great-britain, the Netherlands and Sweden.

Cross-Cultural Comparison↗

Breast cancer and bone mass in older women: is bone density prescreening for mammography useful?

INTRODUCTION: The utility of screening mammography for older women with low bone mineral density (BMD) is controversial. This case-control study compares BMD at multiple sites in women with and without breast cancer to determine if BMD prescreening is useful in selecting women for continued screening mammograms. METHODS: Women diagnosed with breast cancer in the preceding 4 months and age-matched controls (+/-2 years) with a normal mammogram, all aged 65 years and older, were recruited on a 1:2 basis; 237 women participated: 79 women (cases) with breast cancer and 158 controls. BMD at the lumbar spine, hip, radius, and whole body was measured with dual x-ray absorptiometry (DXA). RESULTS: Among women with breast cancer, 17.1% had stage 0, 41.5% stage I, 40.0% stage II, and 1.4% stage III. Women with breast cancer had larger waist circumferences (p=0.002) and waist-hip ratios (p=0.01), and they exercised less (p=0.002) than women of the control group. However, there were no differences between the cases and controls for age, obesity, and reproductive and menopausal history variables, or other covariates (p>0.10). There were no differences in lumbar spine, total hip, femoral neck, midshaft radius, or total body BMD (p>0.10), although the cases had higher BMD at the ultradistal radius than the controls (means: 0.527 vs. 0.516, respectively; p=0.014). There were no differences in breast cancer risk by tertile of BMD or osteoporosis status at the hip or spine. CONCLUSION: There is little difference in BMD between women with and without breast cancer. BMD is not useful as a prescreening predicator of mammography in older women and using it as such would result in cases of breast cancer being missed.

Aged↗

[Experiences of the Bavarian mammography screening program].

The Bavarian Mammography Screening Program started in April 2003. A detailed analysis of the consistency of diagnosis in the evaluation of vacuum-assisted stereotactic or core needle breast biopsies is presented. A total of 32 pathologists participated in a blinded evaluation of the biopsies. Each case was evaluated independently by two participating pathologists. A total of 1,357 cases were reviewed. The histopathological reports of the biopsies made by the two consulting pathologists were compared. The concordance rate of the first and second consulting pathologist was 93% for the B-classification. In general, the level of diagnostic agreement was very high for well defined, benign and malignant lesions. Some of the discrepancies resulted from the incorrect application of the B-classification. Discrepancies in the reports were also due to divergent interpretation of benign and "borderline" lesions. The protocol for the blinded evaluation of breast biopsies in two rounds assured a high level of quality. In conclusion, prerequisites for the success of a mammography screening program are interdisciplinary consensus conferences and audit rounds involving pathologists.

Biopsy, Needle↗

Is the "blooming sign" a promising additional tool to determine malignancy in MR mammography?

The aim of this study was to evaluate potential diagnostic relevance of blooming effect for verification of suspicious breast lesions in MR mammography (MRM). The MRM examinations of 1035 patients, all following the same imaging protocol (from 1994 to 2001) were retrospectively evaluated by two experienced radiologists in consensus. A total of 817 lesions showed a focal enhancement; of these, 793 were histologically verified after surgical intervention so that 514 malignant and 279 benign lesions could be evaluated. Using a 1.5-T Gyroscan ACS II-imager (Philips, Hamburg, Germany) and a double breast coil with the patient lying in a prone position, 0.1 mmol/kgbw Magnevist (Schering, Berlin, Germany) were injected into the cubital vein to obtain dynamic axial and coronal T1-weighted fast-field-echo images every minute up to 7 min after bolus injection. Blooming sign describes a progradient unsharpness of lesion borders initially sharply shaped and fast enhancing 7 min after bolus injection; 324 of 514 (63.0%) malignant lesions and 41 of 279 (14.7%) benign lesions revealed a blooming sign (sensitivity 63.0%, specificity 85.3%, accuracy 70.9%, positive predictive value 88.8%, negative predictive value 56.0%). Forty-one of 279 benign lesions showed a blooming sign; of these, there were 4 of 86 (4.7%) fibroadenomas, 2 of 21 (9.5%) phylloides tumours, 11 of 38 (28.9%) papillomas, 3 of 9 (33.3%) radial scars, 2 of 19 (10.5%) mastitis, 1 of 4 (25%) galactophoritis, 1 of 3 (33.3%) ADH and 19 of 99 (17.2%) mastopathic proliferations, respectively. Blooming sign is a phenomenon which should be taken into account when diagnosing MR mammographies because it might increase the ability to discriminate uncertain breast lesions; however, this effect can only be used as an additional item to other well-known effects such as plateau, washout and cancer corner.

Adult↗

Digital detectors for mammography: the technical challenges.

This paper reviews the different techniques available and competing for full-field digital mammography. The detectors are described in their principles: photostimulable storage phosphor plates inserted as a cassette in a conventional mammography unit, dedicated active matrix detectors (i.e., flat-panel, thin-film transistor-based detectors) and scanning systems, using indirect and direct X-ray conversion. The main parameters that characterize the performances of the current systems and influence the quality of digital images are briefly explained: spatial resolution, detective quantum efficiency and modulation transfer function. Overall performances are often the result of compromises in the choice of technology.

Equipment Design↗