Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “MAGNETISM”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91Linked to original sources

Remanence due to wall magnetization and counterintuitive magnetometry data in 200-nm films of Ni.

200-nm-thick Ni films in an epitaxial Cu/Ni/Cu/Si(001) structure are expected to have an in-plane effective magnetic anisotropy. However, the in-plane remanence is only 42%, and magnetic force microscopy domain images suggest perpendicular magnetization. Quantitative magnetic force microscopy analysis can resolve the inconsistencies and show that (i) the films have perpendicular domains capped by closure domains with magnetization canted at 51 degrees from the film normal, (ii) the magnetization in the Bloch domain walls between the perpendicular domains accounts for the low in-plane remanence, and (iii) the perpendicular magnetization process requires a short-range domain wall motion prior to wall-magnetization rotation and is nonhysteretic, whereas the in-plane magnetization requires long-range motion before domain-magnetization rotation and is hysteretic.

Journal Article↗

Achieving Magnet accreditation in the UK: a case study at Rochdale NHS Trust.

AIMS: This study explored the Magnet accreditation process in the first health care organization outside the USA to attempt to gain the award, Rochdale NHS Trust United Kingdom. The development was supported by the American Nurses Credentialing Center as a pilot project and the research conducted as a case study in organizational response to the requirements of a new accreditation system. METHOD: Information was collected via 23 face-to-face and three telephone interviews carried out with 11 senior figures at Rochdale during the 2-year period of the Magnet project, from field notes of meetings attended by the researchers and from analysis of documents associated with the project. RESULTS: The work of applying for Magnet accreditation built upon a previous 2-3 year programme of shared governance and clinical leadership throughout the Trust which senior staff felt had been an essential foundation for the Magnet project. The process enabled staff to assemble evidence which held up a mirror to their practice and contributed to other quality-related initiatives. The experience at Rochdale suggests that Magnet enables care areas to identify and celebrate examples of good practice and for lessons to be learned and shared within the organization. Although the Magnet concept is primarily nursing oriented, medical and allied health professionals were able to contribute and benefit. The application was successful and Rochdale was awarded Magnet status in April 2002. CONCLUSIONS: The Magnet project at Rochdale was essentially a process of collecting evidence to formally recognize previous leadership initiatives and their effects within the organization. The emergent approach to implementing the Magnet project was one which attempted to integrate and utilize existing systems and resources. The project provides evidence that Magnet can be transferred to non-US health care systems. The principal issues associated with this transfer were the costs incurred, the interpretation of terminology and the engagement of medical and allied health professionals.

Accreditation↗

Noninvasive verification of nasogastric tube placement using a magnet-tracking system: a pilot study in healthy subjects.

BACKGROUND: Fluoroscopic verification of nasogastric (NG) feeding tube placement is inconvenient and involves radiation exposure. We tested whether the position of an NG tube can be assessed reliably by a recently introduced magnet-tracking system. METHODS: A small permanent magnet was attached at the end of an NG tube and its position was monitored using an external sensor array connected to a computer. NG tube trajectory, spontaneous movements of the magnet, and its position relative to the lower esophageal sphincter (LES) and xiphisternum were assessed in 22 healthy subjects and compared with esophageal manometry. In 12 subjects, localization of the magnet was also compared with fluoroscopy. RESULTS: Magnet-tracking displayed NG tube tip movement reproducibly as it moved vertically in the esophagus and then laterally into the stomach. Compared with manometry, the accuracy and sensitivity of magnet tracking for localization of the NG tube tip, above or below the diaphragm, were 100%. Compared with fluoroscopy, the accuracy of NG tube localization by magnet tracking was 100%. With the magnet in the stomach, but not in the esophagus or LES, low amplitude displacements at a frequency of 3 per minute, consistent with gastric slow wave activity, were observed. CONCLUSIONS: Magnet tracking allows accurate, real-time, 3-dimensional localization of an NG tube with respect to anatomic landmarks. Recorded motor patterns are indicative of the position of the NG tube. Magnet tracking may be a useful tool for bedside placement of nasogastric and enteral feeding tubes.

Adult↗

ACQUISITION OF MAGNETIC DIRECTIONAL PREFERENCE IN HATCHLING LOGGERHEAD SEA TURTLES

During their natal migration, hatchling loggerhead sea turtles (Caretta caretta L.) establish courses towards the open ocean and maintain them after swimming beyond sight of land. Laboratory experiments have demonstrated that swimming hatchlings can orient using the earth's magnetic field. For the magnetic compass to function in guiding the offshore migration, however, hatchlings must inherit or acquire a magnetic directional preference that reliably leads them towards the open sea. On land, hatchlings find the ocean using light cues associated with the seaward horizon. To determine whether turtles might acquire a preference for a specific magnetic direction on the basis of such cues, we studied the magnetic orientation of turtles initially exposed to light from either magnetic east or west. Hatchlings that had been exposed to light in the east subsequently oriented eastward when tested in darkness, whereas those that had been exposed to light in the west swam westward. Reversing the magnetic field resulted in a corresponding shift in orientation, indicating that the turtles were orienting to the ambient magnetic field. These results demonstrate that light cues can set the preferred direction of magnetic orientation by loggerhead hatchlings. We therefore hypothesize that hatchlings initially establish a seaward course using visual cues available on or near land, then maintain the course using magnetic cues as they migrate into the open sea.

Journal Article↗

Magnetic fields and mammary cancer in rodents: a critical review and evaluation of published literature.

Epidemiological data suggesting a possible increase in breast cancer risk in male electricians have raised concerns about the relationship between exposure to power-frequency magnetic fields and breast cancer. In this paper, we review the results of animal studies that are relevant to identifying possible increases in breast cancer risk resulting from exposure to 50 or 60 Hz magnetic fields. Three large-scale chronic bioassays of carcinogenesis in rats or mice exposed to magnetic fields for 2 years demonstrated no increases in the incidence of mammary cancer; it is generally accepted that power-frequency magnetic fields have little or no activity as a complete carcinogen in the rodent mammary gland. Findings from one laboratory, though inconsistent, suggest that magnetic fields may stimulate mammary neoplasia in rats treated with a chemical carcinogen. However, studies conducted in two other laboratories failed to confirm these findings; rats exposed to magnetic fields demonstrated patterns of tumor incidence, multiplicity, size and latency that were generally similar to those in sham-exposed controls. Where differences were seen, the groups exposed to magnetic fields generally had fewer mammary tumors than did sham-exposed controls. On this basis, evaluations of the activity of 50 or 60 Hz magnetic fields in models of multistage mammary cancer in rodents have generally been negative; positive findings have been reported from only one laboratory. The totality of rodent data does not support the hypothesis that power-frequency magnetic-field exposure enhances mammary cancer in rodents, nor does it provide experimental support for possible epidemiological associations between magnetic-field exposure and increased breast cancer risk.

9,10-Dimethyl-1,2-benzanthracene↗

Magnetic fields alter the circadian periodicity of seizures.

We have recently reported that application of external, weak magnetic fields attenuated seizures in epileptic patients (Anninos et al., 1991). However, the mechanisms by which magnetic stimulation reduces seizure activity are unknown. We present four non-selected epileptic patients the first to be rated by the senior author, in whom treatment with magnetic fields attenuated the severity of seizures and also altered the circadian occurrence of seizures. The first patient, a 27-year old woman, had generalized tonic-clonic seizures which occurred almost exclusively at night. Following treatment with magnetic fields she experienced attenuation of seizures which then occurred only after waking up in the morning. The second patient, a 42-year old man, had generalized tonic-clonic seizures which occurred randomly during the day and night. Treatment with magnetic fields resulted in disappearance of nocturnal seizures with seizures now occurring exclusively during the day. The third patient, a 21-year old woman had generalized tonic-clonic seizures which occurred randomly during the day. After treatment with magnetic fields she was free of seizures for 7 months, but recently experienced one attack in the morning hours while sleeping. The fourth patient, a 39-year old woman had secondary generalized seizures since the age of 12. Prior to treatment with magnetic fields she had 8-10 seizures daily which occurred randomly during the day and night hours. Magnetic treatment resulted in attenuation in seizure frequency (1-2/day) with seizures now occurring only during the day. We propose, therefore, that since the pineal gland is a magnetosensitive organ which "transduces" environmental information of the light-dark cycle and of the earth's magnetic field into an endocrine message mediated via the circadian release of melatonin, and since it is recognized that melatonin attenuates seizure activity, artificial magnetic fields attenuate seizure activity by altering the functions of the pineal gland.

Adult↗

Within-day variability of magnetic fields among electric utility workers: consequences for measurement strategies.

Occupational exposure to 50-Hz magnetic fields was surveyed among electric utility workers to investigate (1) components of exposure variability, (2) patterns of autocorrelation between short-term measurements, and (3) imprecision and misclassification due to short-term measurements. Spot measurements every 10 seconds during 81 working days were analyzed for 42 electric utility workers from 10 occupational subgroups and during 8 working days for 4 office workers from the same company. For the 8-hour time-weighted average (TWA) magnetic fields, the variability was partitioned into its components: within workers, between workers, and between groups. For spot measurements of magnetic fields, the within-day variance component also was examined. Autocorrelation functions were determined and numbers of short-term measurements necessary for reliable estimates of 8-hour TWA magnetic fields were assessed. Spot measurements of magnetic fields, as well as 8-hour TWA magnetic fields, were approximately lognormally distributed among workers. The mean exposure to magnetic fields was 0.47 microT (n = 81 days) in electric utility workers and 0.12 microT (n = 8 days) in office workers. A large fraction, 76% of the spot measurements total variance, could be attributed to variability within days. For the 8-hour TWA magnetic fields, between-group variability was small and of the same magnitude as between-worker variability. Significant autocorrelations between short-term averages of 7.5, 15, and 30 minutes were present, when taken within periods of 30 minutes. One-hour averages showed no autocorrelation. Simulations showed that, due to high within-day variability and autocorrelation, a limited number of short-term measurements of magnetic fields in electric utility workers are likely to result in imprecise estimates of 8-hour TWA magnetic fields. Measurement strategies relying on short-term (spot) measurements are therefore likely to result in misclassification of exposure and consequently absent or spurious exposure-response relations.

Electromagnetic Fields↗

[The role of magnetic stimulation in diagnosis of the peripheral nervous system].

Magnetic stimulation has recently been introduced as a new method for stimulation of neuronal tissues. Up to now most investigators were emphasized the advantages of this method for the investigation of the central nervous system. With this paper we want to show that magnetic stimulation may also be useful for the examination of the peripheral nervous system. Both, magnetic and electrical stimulation, seem to employ the same stimulation mechanisms in the nervous tissue. The results obtained with both methods should therefore be comparable. By measuring EMG-latencies after electrical and magnetic stimulation (Fig. 1) the exact site of magnetic stimulation can be determined. Magnetic stimulation offers major advantages over electrical stimulation: 1) Magnetic stimulation is a painless method even when high stimulus intensities are used. 2) Magnetic stimulation can reach deep neuronal structures that are not easily accessible using electrical stimulation (Fig. 2, Fig. 3). 3) Using a wide range of stimulus intensities (Fig. 4, Fig. 5) magnetic stimulation provides a much better descrimination of different components of the compound muscle action potential than electrical stimulation. Magnetic stimulation seems to be a promising new method for the electrodiagnostic examination of pain- sensitive patients, especially when deep-lying peripheral nerves have to be investigated.

Electric Stimulation↗

Magnetic field activation of protein-DNA binding.

The mechanisms involved in sensing, signaling, and coordinating changes resulting from magnetic field-induced stress show substantial similarities to those of heat shock, e.g., magnetic field-induced heat shock 70 gene (HSP70) expression involves heat shock factor (HSF) activation and heat shock element binding. However, an additional requirement for transactivation of HSP70 expression by magnetic fields is the binding of Myc protein, indicating that additional elements and/or pathways are involved in the induction of HSP70 expression by magnetic fields. To investigate the possible participation of additional genetic elements in magnetic field-induced HSP70 expression, we examined both magnetic field exposure and heat shock on protein-DNA binding of the transcription factors HSF, AP-1, AP-2, and SP-1 in four human cell lines. The binding sites for these transcription factors are present in the HSP70 promoter. AP-1 binding activity, normally not increased by heat shock, was increased by magnetic fields; heat shock induced an increase only in HSF binding. Although intersecting and converging signaling pathways could account for the multiplicity of elements involved in magnetic field-induced HSP70 transcription, direct interaction of magnetic fields with DNA is also a possible mechanism. Because magnetic fields penetrate the cell, they could well react with conducting electrons present in the stacked bases of the DNA.

Binding, Competitive↗

Exposure of female rats to a 100-microT 50 Hz magnetic field does not induce consistent changes in nocturnal levels of melatonin.

The hypothesis whereby alternating (50 or 60 Hz) magnetic fields such as those produced by electric power reduce the nocturnal production of melatonin in the pineal gland and thereby indirectly enhance development and growth of breast cancer has attracted a great deal of interest. In view of the potential importance of this hypothesis that there is a link between electric power and breast cancer, which is also known as the "melatonin hypothesis", we undertook various experiments in female Sprague-Dawley rats to evaluate whether 100-microT 50 Hz magnetic-field exposure, i.e. a flux density shown recently to exert a tumor (co)promoting effect in the 7,12-dimethylbenz[a]anthracene (DMBA) model of breast cancer in Sprague-Dawley rats, consistently reduces melatonin levels and, if not, which factors may be involved in the inconsistent effects of magnetic-field exposure on production of melatonin. Long-term exposure of female Sprague-Dawley rats to magnetic fields for 13 weeks did not alter the nocturnal levels of melatonin in the pineal gland or serum (determined 5 h after the onset of darkness) significantly, irrespective of whether rats were treated with DMBA or not. In one experiment, when blood was sampled 3, 5 and 6 h after the onset of darkness after 2 weeks of magnetic-field or sham exposure, a significant decrease in melatonin was seen in magnetic-field-exposed rats at 6 h. However, the results could not be reproduced in two subsequent experiments in other groups of rats. Shorter (1 day, 1 week) or longer (4, 8, 13 weeks) exposure periods also did not result in any significant effects of the magnetic field on melatonin levels when blood sampling was performed either 5 or 6 h after onset of the dark phase. Various potential sources of variation in melatonin levels or in magnetic-field effects on melatonin levels were evaluated, but the reason(s) for the inconsistent effect of magnetic-field exposure remains unclear. Thus the present study failed to demonstrate a consistent effect of 100-microT 50 Hz magnetic-field exposure on melatonin levels in Sprague-Dawley rats.

9,10-Dimethyl-1,2-benzanthracene↗

Theory of 1/T1 and 1/T2 NMRD profiles of solutions of magnetic nanoparticles.

Organically coated iron oxide crystallites with diameters of 5-50 nm ("nanoparticles") are potential magnetic resonance imaging contrast agents. 1/T1 and 1/T2 of solvent water protons are increased dramatically by magnetic interactions in the "outer sphere" environment of the nanoparticles; subsequent diffusive mixing distributes this relaxation throughout the solvent. Published theory, valid for the solute magnetic energy small compared with thermal energy, is applicable to small magnetic solutes (e.g., gadolinium and manganese diethylenetriaminopentaacetic acid, and nitroxide free radicals) at generally accessible fields (< or = 50 T). It fails for nanoparticles at fields above approximately 0.05 T, i.e., at most imaging fields. The authors have reformulated outer sphere relaxation theory to incorporate progressive magnetic saturation of solute nanoparticles and, in addition, indicate how to use empirical magnetization data for realistic particles when their magnetic properties are not ideal. It is important to handle the effects of rapid thermally induced reorientation of the magnetization of the nanoparticles (their "superparamagnetism") effectively, including their sensitivity to particle size. The theoretical results are presented as the magnetic field dependence (NMRD profiles) of 1/T1 and 1/T2, normalized to Fe content, for three sizes of particles, and then compared with the limited data extant for well-characterized material.

Algorithms↗

Lanthanide-based susceptibility contrast agents: assessment of the magnetic properties.

The T2* contrast efficacy of paramagnetic contrast agents is dependent on their magnetic properties. Vibrating sample magnetometry (VSM) and the Live Chan NMR method have been used to evaluate the influence of ligand structure on the bulk magnetic susceptibility (BMS) of low-molecular weight (LMW) lanthanide chelates. VSM was also used for the BMS assessment of LMW lanthanide chelates covalently attached to cross-linked starch particles. The ligand structure had no influence on the BMS of the gadolinium (Gd) and dysprosium (Dy) chelates. The mean BMS value of the Dy-chelates was 1.8 fold higher than that of the Gd-chelates. The holmium (Ho) DTPA-BMA chelate had a similar BMS to that of Dy-DTPA-BMA while the lowest BMS was found for europium (Eu(III)) DTPA-BMA. The covalent attachment of Gd-DTPA and Dy-DTPA to a cross-linked starch particle had no impact on their intrinsic magnetic properties. The BMS data were in good accordance with those obtained for non-particulate bound LMW Dy- and Gd-chelates. The magnetic susceptibility of the Gd-DTPA labeled particles was described by the Curie law, indicative of no magnetic interactions between Gd-DTPA molecules. The magnetic susceptibility of the Dy-DTPA labeled particles followed the Curie-Weiss law with a Curie-Weiss temperature of about-2 K, indicating magnetic interactions. The magnetic susceptibility of Dy-DTPA will, however, not be affected by such magnetic interactions at physiological temperatures.

Contrast Media↗

Therapy monitoring in human and canine soft tissue sarcomas using magnetic resonance imaging and spectroscopy.

PURPOSE: The goals of this study were to determine whether magnetic resonance parameters (a) can identify early during therapy those patients most likely to respond to hyperthermia and radiotherapy, (b) can provide prior to or early during therapy information about the temperature distributions which can be obtained in patients receiving hyperthermia, and (c) can provide an understanding of the effects of hyperthermia on tumor metabolic status. METHODS AND MATERIALS: Twenty-one human patients and 10 canine patients with soft tissue sarcomas treated with preoperative hyperthermia and radiation had a series of magnetic resonance imaging and phosphorous spectroscopy studies done. To address the goals for both the human and canine populations, changes in mean T2 relaxation times, pH, and various phosphometabolite ratios from the pretreatment (Study 1) to the post first hyperthermia study (Study 2) were correlated with treatment outcome; pretreatment magnetic resonance parameters and changes in magnetic resonance parameters (Study 2-Study 1) were compared with various cumulative thermal descriptors; and thermal descriptors of the first hyperthermia were compared with changes in magnetic resonance phosphometabolite ratios. RESULTS: A decrease in adenosine triphosphate/phosphomonoester from study 1 to study 2 is associated with a greater chance of > or = 95% necrosis in surgical resected tumors from human patients, but no significant relationships were observed between changes in tumor pH or phosphometabolite ratios and time to local failure in dogs. Pretreatment magnetic resonance parameters correlated with various thermal dose descriptors in canines but not in humans. Change in adenosine triphosphate/inorganic phosphate and phosphomonoester signal to noise ratio correlated with cumulative thermal descriptors in dogs and humans, respectively. In dogs only, increases in thermal dose resulted in decreases in high energy phosphometabolites. CONCLUSION: Changes in magnetic resonance parameters early during therapy may be predictive of treatment outcome. Pretreatment and changes in magnetic resonance parameters appear to predict how well a tumor will be heated during hyperthermia. Magnetic resonance spectroscopy also appears to be a useful tool to study the effects of various thermal doses on tumor metabolic status.

Adenosine Triphosphate↗

Short-term exposure to a 1.5 tesla static magnetic field does not affect somato-sensory-evoked potentials in man.

The literature is contradictory regarding the effect of static magnetic fields on the function of the central nervous system of mammals. Since human subjects are exposed to intense static magnetic fields during magnetic resonance imaging, it is important to determine if the static magnetic field adversely affects the nervous system of man. Therefore, somato-sensory evoked potentials (SEPs) elicited from median nerve stimulation were measured in 11 normal subjects before and during short-term exposure to a 1.5 Tesla static magnetic field. Specially modified instrumentation was used to record SEPs that were unperturbed by the static magnetic field. There were no statistically significant differences in the N20 or P25 latencies or in the amplitude from N20 negative peak to P25 positive peak of the SEPs obtained before compared to those recorded during exposure to the static magnetic field. In addition, there were no changes in the waveforms associated with exposure to the static magnetic field. We conclude that short-term exposure to a 1.5 Tesla static magnetic field does not affect SEPs (i.e., nerve conduction and synaptic transmission were within normal limits) in normal human subjects.

Adult↗

Magnetic resonance force microscopy with a ferromagnetic tip mounted on the force detector.

The Magnetic Resonance Force Microscope (MRFM) presents the opportunity for a magnetic resonance imaging probe with ultra-high, potentially atomic-scale, resolution. The successful application of this technique in detection of nuclear magnetic, electron-spin and ferromagnetic resonance (FMR) highlights its significant potential. We discuss the capabilities of the MRFM with particular emphasis on the detection of FMR using MRFM techniques. A crucial remaining challenge in the development of the magnetic resonance force microscope (MRFM) is to place the magnetic probe on the mechanical resonator. We address the problem of spurious detector response arising from interactions between the magnetic tip and various external applied fields. We show that miniature, magnetically-polarized Nd2Fe14B particles show promise as magnetic probe tips. Our experience indicates it will be important to minimize the total polarized moment of the magnetic tip and to ensure that the applied fields are as uniform as possible.

Ferric Compounds↗

Magnetic relaxation switches capable of sensing molecular interactions.

Highly sensitive, efficient, and high-throughput biosensors are required for genomic and proteomic data acquisition in complex biological samples and potentially for in vivo applications. To facilitate these studies, we have developed biocompatible magnetic nanosensors that act as magnetic relaxation switches (MRS) to detect molecular interactions in the reversible self-assembly of disperse magnetic particles into stable nanoassemblies. Using four different types of molecular interactions (DNA-DNA, protein-protein, protein-small molecule, and enzyme reactions) as model systems, we show that the MRS technology can be used to detect these interactions with high efficiency and sensitivity using magnetic relaxation measurements including magnetic resonance imaging (MRI). Furthermore, the magnetic changes are detectable in turbid media and in whole-cell lysates without protein purification. The developed magnetic nanosensors can be used in a variety of biological applications such as in homogeneous assays, as reagents in miniaturized microfluidic systems, as affinity ligands for rapid and high-throughput magnetic readouts of arrays, as probes for magnetic force microscopy, and potentially for in vivo imaging.

Base Sequence↗

Design and implementation of magnetization transfer pulse sequences for clinical use.

The transfer of magnetization between a free and a bound pool of spins is described in terms of the respective longitudinal relaxation times and the life times of spins in each pool. The effect of an off resonance radiofrequency (RF) pulse in producing saturation in the bound pool and a consequent decrease in both the available longitudinal magnetization and the T1 of spins in the free pool is described. The effects of increasing duration of the saturating RF pulse on image pixel signal intensity were used to determine values for the decrease in both T1 and the available magnetization in gray and white matter of the brain as well as in muscle, fat, and CSF. At 0.15 T the available magnetization of muscle was reduced by approximately 60% and its T1 was decreased from 350 to 150 ms. The available magnetization of white and gray matter was reduced by 40% and their values of T1 were reduced by 80-110 ms. The reduction in available magnetization was used to increase contrast on proton density weighted or T2-weighted SE pulse sequences. These changes were also used to design inversion recovery (IR) pulse sequences with particular contrast properties. A short inversion time (TI) magnetization transfer (MT) IR (MT-STIR) pulse sequence was used to reduce the signal from normal muscle to zero to produce an angiographic effect in the leg. Increased tissue contrast was observed with a T2-weighted (MT-SE) sequence in a patient with bilateral cerebral infarction and with an MT-IR pulse sequence in a patient who had an intracranial hematoma. Three patients with cerebral tumors showed high lesion contrast with MT-STIR sequences. Components within two tumors were changed to different degrees by MT and in one case change in the brain attributable to recent radiotherapy treatment was only identified with an MT-STIR sequence. Magnetization transfer can be used to manipulate both the available longitudinal magnetization and the T1 of normal and abnormal tissues. The changes in tissue contrast produced by this can be very substantial and are likely to be of importance in clinical imaging.

Adult↗

Transcranial magnetic stimulation: the method and application.

Transcranial magnetic stimulation is a noninvasive method for stimulation of brain that is based on the ability of magnetic field to penetrate skull and brain meninges, subsequently inducing electric current in the brain tissues that produces neuronal depolarization and generation of action potentials. Moreover, transcranial magnetic stimulation has effects on neurochemical and synaptic processes in neurons. Due to its easy use and relatively fair side effects, nowadays, transcranial magnetic stimulation is widely used in neurosciences and medicine. The main areas of transcranial magnetic stimulation application are: 1) the investigation of cortical and spinal excitability, 2) the investigation of neuronal plasticity, 3) the investigation of neuronal connectivity, 4) functional mapping, and 5) the treatment of some neurological and psychiatric disorders. Transcranial magnetic stimulation alone or in combination with other noninvasive neuroimaging (PET--positron emission topography, MRI--magnetic resonance imaging) and neurofunctional (EEG--electroencephalography, ERP--event-related potentials, fMRI--functional magnetic resonance imaging) methods allows conducting research on brain functions. Thus, transcranial magnetic stimulation is suitable as a diagnostic tool in neurologic and neuropsychiatric brain research.

Action Potentials↗