Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Fractures, Compression”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91Linked to original sources

Percutaneous compression plating for intertrochanteric hip fractures: treatment rationale.

Percutaneous compression plating was developed after thorough consideration of each stage in the surgical procedure for intertrochanteric fractures and the ways in which they might be improved. This system represents a minimally invasive method of fracture stabilization and fixation, providing enhanced rotational stability and bone sparing, which reduces both peri- and postoperative complications including cut outs and fracture collapse.

Aged↗

Application of a lateral compression clamp in the management of mandibular fractures.

A lateral compression clamp system has been used in the treatment of fractures of the mandible. It provides rigid fixation and promotes earlier osteogenesis at the fracture site. Intermaxillary fixation can often be eliminated in edentulous persons and greatly reduced in duration when necessary as an adjunct to fixation in patients with teeth. These significant qualities make the compression clamp quite beneficial in the treatment plan and postoperative management of many otherwise difficult cases. Having evaluated our experiences with compression clamps, we believe that this approach deserves further attention and may contribute to a solution of the controversy that often exists regarding the management of mandibular fractures in both edentulous patients and those with a compromised complement of teeth.

Accidents, Traffic↗

Tibial shaft fractures. The frequency of local complications in tibial shaft fractures treated by internal compression osteosynthesis.

Ninety-two tibial shaft fractures in 90 patients over the age of 15 were treated by compression osteosynthesis according to the AO method, but using plates and screws of Vitallium. Fifteen fractures (14 patients) were excluded, because the follow-up period was less than 12 months. The frequency of complications in the remaining 77 fractures, 44 per cent comminuted and 30 per cent open fractures, were: skin necrosis over the osteosynthesis material: 5.2 per cent, osteitis: 1.3 per cent, delayed osseous healing necessitating secondary operation: 2.6 per cent, loosened screw (not requiring secondary operation): 5.2 per cent, loosened screw + refracture: 1.3 per cent, plate bending: 1.3 per cent, plate fractured: 1.3 per cent, and refracture after removal of the plate (new relevant traumas): 4.8 per cent. In this series there was a markedly high frequency of complications in comminuted fractures with laceration of skin and muscles, whereas an increased tendency for complications to develop in the remaining injury groups was not seen.

Adolescent↗

Case report: central venous catheter fracture due to compression between the clavicle and first rib.

A central venous catheter inserted via the subclavian route may be compressed by the clavicle and adjacent first rib. This appearance on a radiograph has been previously described as the 'pinch-off sign' and indicates the need to remove the catheter, due to a significant risk of subsequent fracture. A case and its management are presented, followed by discussion of the radiographic appearances and their cause.

Adult↗

Treatment of femoral neck fractures with the sliding compression screw.

Twenty-nine patients with intracapsular fractures of the femur were treated with a sliding compression screw. The overall incidence of unsatisfactory results was 48%. In the combined group of Garden III-type and Garden IV-type fractures, 58% had unsatisfactory results. The Garden IV type fractures, considered separately, had 89% unacceptable results. The most significant factors associated with an unsatisfactory result were: (1) poor reduction; (2) poor alignment or depth of the screw; and (3) the use of the long threaded lag screw. Inability to control the proximal fragment during the procedure made it difficult to maintain satisfactory reduction and may have contributed to avascular necrosis in seven of the 29 hips. Displaced fractures of the femoral neck are difficult to reduce and transfix. The sliding compression screw did not compensate for a technically poor reduction or unsatisfactory surgical placement of the device.

Bone Screws↗

[Compression hip screw in trochanteric fractures. Conclusions based on 128 cases].

Compression hip screw is currently used in our department since 1998 and we operated 128 trochanteric fractures using DHS (Synthes) or Omega system (Howmedica-Stryker). We recommend the use of this implant in all stable fractures, most unstable fractures and we believe it is useless in reverse oblique trochanteric fractures. Best time for surgery seems to be the first or second day after admission. A preoperative planning must precede the surgery. We prefer the lateral approach of the hip with "L" type incision for vastus lateralis. For insertion of implant AO original technique was used. Mechanical complication occur only in unstable fractures but the failure rate was lower than for other implants. Patient with stable fractures were allowed full weight bearing immediately postoperative, this being delayed 6 weeks for patients with unstable fractures. We recommend compression hip screw as a very useful implant in trochanteric fractures.

Biomechanical Phenomena↗

Unilateral S-1 root compression syndrome caused by fracture of the sacrum.

Unilateral S-1 nerve root compression after an S-1 sacral fracture was found in an 18-year-old man after a motor vehicle accident. The positive myelogram, myelogram-computed tomogram, and magnetic resonance studies led to surgical intervention. Marked bony callous formation contiguous with the S-1 alar fracture protruded into the canal and was responsible for tethering the S-1 nerve root. A right L-5 hemilaminectomy, an L-4, L-5 and L-5, S-1 medial facetectomy, and foraminotomy facilitated nerve root decompression. Postoperatively, the patient was markedly improved. The authors suggest a more aggressive attitude in the diagnostic, radiographic, and surgical management of sacral fractures now that more specific technical facilities are available to define the precise character of the lesions involved.

Adolescent↗

Fracture of the osteoporotic cervical spine from a low-level trauma.

Most cervical spine fractures are caused by high-level trauma or by malignancy. Compression-type fractures usually affect the lumbar and thoracic spine below the T8 level and rarely the cervical spine. In the elderly, however, cervical spine compression fractures can occur with relatively minor trauma and are associated with high morbidity and mortality.

Accidental Falls↗

Occipital condyle fractures: clinical presentation and radiologic detection.

PURPOSE: To describe the CT findings in occipital condyle fractures in patients suffering craniocervical trauma. METHODS: Six occipital condyle fractures in five patients were analyzed. Because of clinical or plain-film findings, the craniocervical junction in each patient was imaged using thin-section, high-resolution CT. Axial data were reformatted in the coronal plane or in both coronal and sagittal planes. Clinical and radiologic findings associated with occipital condyle fractures reported in the English medical literature were correlated with our cases to determine conclusive predictive features indicating condylar injury. RESULTS: Two avulsion (type III) fractures in two patients, two compression (type I) fractures in one patient, and two compression fractures in two patients were diagnosed by CT. Specific predictive features indicating occipital condyle fracture could not be confirmed. CONCLUSIONS: CT greatly facilitates diagnosing and typing of occipital condyle fractures. Nonspecific parameters promoting CT after trauma are unexplained persistent upper-neck pain with normal plain-film findings, lower cranial nerve palsies, spasmodic torticollis, retropharyngeal or prevertebral soft-tissue swelling, and fractures of the atlas or axis.

Cervical Vertebrae↗

[Open reduction and internal fixation of a displaced transverse fracture of the sacrum with a locking compression plate].

Isolated fractures of the distal sacrum are usually caused by direct trauma. Undisplaced fractures are easily missed on conventional X-ray films. CT scans can disclose the full extent of the fracture. Undisplaced, or minimally displaced fractures can be treated conservatively with analgesics and a restriction to seat for six weeks. In cases of major displacement or neurological symptoms, a digital transanal reduction of the fracture under local or regional anaesthesia can be attempted. If this manoeuvre fails, open reduction and internal fixation are required. Stabilisation is challenging because of the thin bone and the complex shape of the sacrum. In a 15 year old girl with major horizontal displacement and comminution of S4, following a snowboard accident, we achieved sufficient and stable fixation with the new LCP (Locking Compression Plate) system. For six weeks after the operation, the patient was not allowed to sit down. Thereafter, she was free of pain and unrestricted in daily activities and sport. The LCP system has a number of advantages in the fixation of fractures in osteoporotic or thin bone, but clinical experience/skill and careful planning of the operation are crucial.

Adolescent↗

Effect of fitting adjustments on compressive strength of a new foil crown system.

The effect of die spacing and precementation internal adjustments on the compressive strength of a new ceramic foil crown system was examined in vitro. Twenty-four ceramic foil crowns were made for identical stylized master dies made of polycarbonate filled with 30 wt% carbon. One half of the stone working dies were coated with die spacer and the remaining were left untreated. A special foil used for these crowns was adapted to the working dies under 2500 psi loading. A sculpturing device was used to standardize the size and shape of the ceramic foil crowns. Only crowns made on dies coated with die spacer received precementation fitting adjustment. All crowns in the two groups were cemented with zinc phosphate cement and were subjected to compressive force until fracture occurred. Compressive strength data were analyzed and compared. Results showed that the use of die spacer and internal adjustments increased the compressive strength of the new ceramic foil crown.

Crowns↗

[A classification proposal for compression-flexion articular fractures of the distal extremity of the radius. A radiographic study of 40 cases].

40 articular fractures of the distal radius with palmar displacement, have been analyzed with Roentnograms. An original classification is proposed for a better initial evaluation of detailed articular damages and displacement. 4 main different types of fracture are described considering for elementary fragments constituted with antero-medial margin, radial styloid and dorsal margin; type A: total anterior margin, type B: separated anterior margin, type C: antero-lateral margin, and type D: antero-medial margin. The two types I and II described by Cauchoix, Duparc and Postel concerning the integrity of the dorsal margin have been incorporated. The quantity of radial gene fractured is determined on lateral view: < 1/2, > or = 1/2, and total. Finally the displacement is typed: anterior dislocation, or anterior translation. An original case of volar dislocated fracture with an intact radial styloid is reported. This classification could drive to specific orientations for treatment: even external fixation often associated with pinning, or alternative buttress plating.

Female↗