Regulatory aspects of invasive glucose measurements.

On May 26, 1976, the Food and Drug Administration (FDA) began implementing the Medical Device Amendments to the Federal Food Drug and Cosmetic Act. These amendments give FDA specific authority to regulate "medical devices." Additional authority was provided in the Safe Medical Devices Act of 1990. The pathways to get in vitro diagnostic products to market for commercial distribution include: premarket notification [or 510(k)] and premarket approval (PMA). Reviews of these applications are performed in the Division of Clinical Laboratory Devices, Office of Device Evaluation within the Center for Devices and Radiological Health. Most submissions for invasive glucose devices are 510(k) applications. Through this process the manufacturer demonstrates that its device is substantially equivalent to another device that is already legally marketed, referred to as the predicate device. To date, noninvasive and minimally invasive glucose testings have been approved through the PMA process and will be discussed in a separate article.

Blood Glucose↗

Gaps, tensions, and conflicts in the FDA approval process: implications for clinical practice.

Despite many successes, drug approval at the Food and Drug Administration (FDA) is subject to gaps, internal tensions, and conflicts of interest. Recalls of drugs and devices and studies demonstrating advantages of older drugs over newer ones highlight the importance of these limitations. The FDA does not compare competing drugs and rarely requires tests of clinical efficacy for new devices. It does not review advertisements before use, assess cost-effectiveness, or regulate surgery (except for devices). Many believe postmarketing surveillance of drugs and devices is inadequate. A source of tension within the agency is pressure for speedy approvals. This may have resulted in "burn-out" among medical officers and has prompted criticism that safety is ignored. Others argue, however, that the agency is unnecessarily slow and bureaucratic. Recent reports identify conflicts of interest (stock ownership, consulting fees, research grants) among some members of the FDA's advisory committees. FDA review serves a critical function, but physicians should be aware that new drugs may not be as effective as old ones; that new drugs are likely to have undiscovered side effects at the time of marketing; that direct-to-consumer ads are sometimes misleading; that new devices generally have less rigorous evidence of efficacy than new drugs; and that value for money is not considered in approval.

Conflict of Interest↗

Hematology and pathology devices; reclassification of the automated differential cell counter. Final rule.

The Food and Drug Administration (FDA) is reclassifying the automated differential cell counter (ADCC) from class III (premarket approval) into class II (special controls). FDA is also identifying the guidance document entitled "Class II Special Controls Guidance Document: Premarket Notifications for Automated Differential Cell Counters for Immature or Abnormal Blood Cells; Final Guidance for Industry and FDA" as the special control that the agency believes will reasonably ensure the safety and effectiveness of the device. This reclassification is being undertaken based on new information submitted in a reclassification petition from the International Society for Laboratory Hematology (ISLH), under the Federal Food, Drug, and Cosmetic Act (the act), as amended by the Safe Medical Devices Act of 1990 and the FDA Modernization Act of 1997.

Blood Cell Count↗

Medical devices; reclassification and codification of the stainless steel suture. Food and Drug Administration, HHS. Final rule.

The Food and Drug Administration (FDA) is announcing that it has issued an order in the form of a letter to Alto Development Corp. (the petitioner) reclassifying the 316L stainless steel suture for use in abdominal wound closure, intestinal anastomosis, hernia repair, and sternal closure from class III (premarket approval) to class II (special controls). The order is being codified in the Code of Federal Regulations (CFR). Although FDA reclassified the device in 1986, it inadvertently neglected to publish a notice of the reclassification in the Federal Register or codify the change in the CFR.

Device Approval↗

Implantable middle ear hearing devices: current state of technology and market challenges.

PURPOSE OF REVIEW: This review of implantable middle ear hearing devices is relevant to hearing professionals and otolaryngologists as an update of technological developments and the status of performance of current devices used in the United States. The 9th International Conference on Cochlear Implants and related Sciences was conducted 14-17 June in Vienna, Austria. Middle ear implantable devices were considered a 'hot topic', as two fully implantable devices are nearing European CE and FDA approval. RECENT FINDINGS: The main themes in this review focus on the fundamental technology applied to middle ear implantables, currently available devices, an overview of devices now off the US market and on challenges in improving performance and reliability. The necessary interplay with manufacturing devices which are more straightforward to surgically place and affordable enough to be accessed by the eligible population of people with hearing loss is discussed. SUMMARY: Indications for middle ear implantable hearing devices are expanding and the reliability of systems continues to improve. Solving problems related to affordability and access has made little progress in comparison, as evidenced by the poor performance of several 'technologically successful' manufacturers in the US market.

Hearing Aids↗

Initial experience with a prototype staple detector.

Stainless steel staples can be overgrown by granulation tissue or skin grafts and become buried in tissue. Although they are generally asymptomatic, they can on rare occasion erode to the surface or complicate the radiographic evaluation of pain not related to the staples. A device to facilitate detection of retained staples would be desirable, but it has been difficult to develop because stainless steel staples have poor magnetic and conductive properties. A prototype device, based on the presence of metal disturbing a low-power electromagnetic field, was developed. With human studies committee approval, this miniaturized detector was used in 13 burn patients to detect staples during planned removal of large numbers of staples. Staples were first removed using visual inspection and palpation of the wounds. This was followed by use of the staple detector. The age of the patients was 10.8 +/- 3.3 years, and burn size was 54.6 +/- 8.8% of the body surface. In 8 (62%) of the patients one or more additional staples were detected by the device that would otherwise have been overlooked. In 4 (31%) of the patients there was a false-positive signal, possibly related to topical silver in the wounds, that required additional focused physical examination. A portable staple detector has been developed. Initial experience with the device is favorable and warrants an expanded trial, which is in the planning stages.

Adolescent↗

Fluoride varnish: a useful new tool for public health dentistry.

Since first shown to be effective by Bibby in 1942, professionally applied topical fluorides have been used successfully as a caries-preventive intervention. In the United States, the acidulated phosphate fluoride (APF) gels have been the most widely used agent for over two decades. While effective, APF has several practical disadvantages, including unpleasant taste and the risk of fluoride overingestion. The use of APF on infants and very young children is not practical or safe. Recently, fluoride varnish has become available in the United States. It has been used widely in Europe and Scandinavia for 25 years. Its effectiveness and safety are documented in over 50 clinical trials. Fluoride varnish is easy to apply, is well accepted by children, and eliminates the risk of overingestion of fluoride. Fluoride varnish is approved by the FDA as a "device" and must be used "off label" for the prevention of caries. Because of the large body of published data documenting its effectiveness and safety, there is no legal risk in using fluoride varnish off label. In fact, the American Dental Association has granted its seal of approval to Duraphat, one of the varnish products. Varnish offers considerable advantages in the dental public health setting. Of particular note, it is practical and safe to apply to the teeth of infants and very young children.

Acidulated Phosphate Fluoride↗

Anterior cruciate ligament replacement: a review.

The anterior cruciate ligament (ACL) is the major intra-articular mechanical element that limits motion of the tibia with respect to the femur. It is a multi-fasciculated structure composed of crimped aligned collagen fibers. The purpose of this paper is to review the literature on ACL structure and mechanical properties in an effort to stimulate the development of a new generation of more effective replacement devices. Replacement of the ACL is achieved using biologic and synthetic grafts. Biologic grafts include illiotibial band, semitendinosus and gracilis tendons, patellar tendon, and meniscus. Bone-patellar-bone complexes used to replace the ACL are revascularized and ultimately replaced by neo-ligament. Synthetic implants including the Integraft, Leads-Keio ligament, Gore-Tex¿ ligament and Kennedy Ligament Augmentation Device (LAD) have either not been approved or approved by the FDA for limited use as a replacement for the ACL. The Kennedy LAD has been found to increase the strength of autogenous tissue during revascularization. Based on the success of autografts and the Kennedy LAD, we conclude that the next generation of ACL replacement devices will consist of a scaffold and a biodegradable augmentation device. The scaffold will have a structure that mimics the normal ACL as well as stimulates revascularization and healing. A biodegradable augmentation device will be employed to mechanically reinforce the scaffold without stress shielding the neo-ligament. By combining the advantages of autografts and a biodegradable augmentation device, a new generation of ACL replacements will be achieved.

Anterior Cruciate Ligament↗

Medical devices; 30-day notices and 135-day PMA supplement review--FDA. Final rule.

The Food and Drug Administration (FDA) is amending its regulations governing the submission and review of premarket approval (PMA) supplements to provide for the submission of a 30-day notice for modifications to manufacturing procedures or methods of manufacture. Amendments are being made to implement revisions to the Federal Food, Drug, and Cosmetic Act (the act) as amended by the Food and Drug Administration Modernization Act of 1997 (FDAMA).

Device Approval↗

Hematology and pathology devices; reclassification; restricted devices; OTC test sample collection systems for drugs of abuse testing. Food and Drug Administration, HHS. Final rule.

The Food and Drug Administration (FDA) is reclassifying over-the-counter (OTC) test sample collection systems for drugs of abuse testing from class III (premarket approval) into class I (general controls) and exempting them from premarket notification (510(k)) and current good manufacturing practice (CGMP) requirements. FDA is also designating OTC test sample collection systems for drugs of abuse testing as restricted devices under the Federal Food, Drug, and Cosmetic Act (the act) and establishing restrictions intended to assure consumers that: The underlying laboratory test(s) are accurate and reliable; the laboratory performing the test(s) has adequate expertise and competency; and the product has adequate labeling and methods of communicating test results to consumers. Finally, FDA is adding a conforming amendment to the existing classification regulation for specimen transport and storage containers to clarify that it does not apply to specimen transport and storage containers that are part of an OTC test sample collection system for the purpose of testing for the presence of drugs of abuse or their metabolites in a laboratory.

Device Approval↗

Medical devices; classification/reclassification of immunohistochemistry reagents and kits--FDA. Final rule.

The Food and Drug Administration (FDA) is issuing a final rule to classify/reclassify immunohistochemistry reagents and kits (IHC's) into three classes depending on intended use. FDA is classifying/reclassifying into class I (general controls) and exempt from premarket notification requirements IHC's used as adjunctive tests and presenting a low risk to public health. FDA is classifying/reclassifying into class II (special control) IHC's that detect or measure certain target analytes and that provide prognostic or predictive data that is not confirmed by routine histopathologic control specimens. The results of the class II IHC's are reported independently to the clinician, and the performance claims are widely accepted and supported by valid scientific evidence. FDA is classifying/reclassifying into class III (premarket approval) IHC's intended for any other use. The scope of products covered by this final rule includes both pre-1976 devices that have not been previously classified, as well as post-1976 devices that are statutorily classified into class III. The intent of this final rule is to regulate pre-1976 devices and post-1976 devices in a consistent fashion. Therefore, FDA is classifying or reclassifying these products as applicable.

Device Approval↗

Hematology and pathology devices; reclassification; restricted devices; OTC test sample collection systems for drugs of abuse testing--FDA. Proposed rule.

The Food and Drug Administration (FDA) is proposing to reclassify over-the-counter (OTC) test sample collection systems for drugs of abuse testing from class III (premarket approval) into class I (general controls), and to exempt them from the premarket notification (510(k)) and current good manufacturing practice (CGMP) requirements. FDA is also proposing to designate OTC test sample collection systems for drugs of abuse testing as restricted devices under the Federal Food, Drug, and Cosmetic Act (the act), and to establish restrictions intended to assure consumers that: The underlying laboratory test(s) are accurate and reliable; the laboratory performing the test(s) has adequate expertise and competency; and the product has adequate labeling and methods of communicating test results to consumers. Finally, FDA is proposing a conforming amendment to the existing classification regulation for specimen transport and storage containers, to clarify that it does not apply to specimen transport and storage containers that are part of an OTC test sample collection system for the purpose of testing for the presence of drugs of abuse or their metabolites in a laboratory.

Consumer Product Safety↗

Technology transfer of neuroprosthetic devices.

Despite long development periods for neuroprosthetic devices, the numbers in clinical use or clinical trials are rising, with an estimated 3,000 systems in use today. As they gain experience with the regulatory approval process, developers are learning to conduct research to best prepare for transfer of technology to industry. The track record of the first motor prosthesis to be approved by the United States Food and Drug Administration contains important lessons for a company planning to undergo the regulatory process. Throughout the development of a neuroprosthesis, the capabilities and preferences of the customers who will use it (physicians, surgeons, therapists, and end-users) should be sought out and used in device design. When a device has reached clinical application, particular attention is needed to maximize both the population who will use it and each individual's degree of use (optimal, partial, reluctant). Identification of person-technology mismatches can help to select training strategies and other interventions that can be applied to ensure a good rehabilitation outcome.

Clinical Trials as Topic↗

Orthopedic devices: reclassification of the hip joint metal/polymer constrained cemented or uncemented prosthesis. Final Rule.

The Food and Drug Administration (FDA) is reclassifying the hip joint metal/polymer constrained cemented or uncemented prosthesis intended to replace a hip joint from class III (premarket approval) to class II (special controls). FDA is also [[Page 21172]] identifying the guidance document entitled "Class II Special Controls Guidance Document: Hip Joint Metal/Polymer Constrained Cemented or Uncemented Prosthesis" as the special control that the agency believes will reasonably ensure the safety and effectiveness of the device. This reclassification is being undertaken based on new information regarding the device contained in a reclassification petition submitted by the Orthopedic Surgical Manufacturers Association (OSMA), under the Federal Food, Drug, and Cosmetic Act (the act), as amended by the Medical Device Amendments of 1976 (the 1976 Amendments), the Safe Medical Devices Act of 1990 (SMDA), and the Food and Drug Administration Moderization Act of 1997 (FDAMA). FDA is also revising the device identification to accurately describe the device.

Device Approval↗

Medical devices; reclassification and codification of the nonabsorbable expanded polytetrafluoroethylene surgical suture. Food and Drug Administration, HHS. Final rule.

The Food and Drug Administration (FDA) is announcing that it has issued an order in the form of a letter to W.L. Gore and Associates, Inc., reclassifying the nonabsorbable expanded polytetrafluoroethylene (ePTFE) surgical suture intended for use in soft tissue approximation and ligation, including cardiovascular surgery, from class III (premarket approval) to class II (special controls). Accordingly, the order is being codified in the Code of Federal Regulations (CFR).

Device Approval↗

Doppler-guided regulation of a telemetrically operated adjustable pulmonary banding system.

OBJECTIVES: We report on the Doppler-assessed regulation of an adjustable pulmonary artery band (PAB) in an animal model and in our first group of patients. BACKGROUND: Indications for pulmonary artery banding have expanded to include patients requiring a late arterial switch. A telemetry-operated, fully implantable, adjustable PAB system (FloWatch- PAB, Endoart SA, Lausanne, Switzerland) has been developed to facilitate these operations. METHODS: The device was implanted in 13 minipigs (age one to five months, weights 3.2 to 12.0 kg). The main study was performed on nine minipigs with adjustments of the PAB at implantation and at 1, 3, 5, 8, and 12 weeks after, assessed by Doppler pressure gradients. Explanation was performed 12 weeks after surgery. A long-term histology study (6 months and 14 months after surgery) was done on the other four minipigs. After approval by the ethics committee, the device was implanted in eight patients with weights between 2.8 and 9 kg to decrease pulmonary blood flow and pressure and to retrain the left ventricle before arterial switch. The device was progressively tightened, with increasing transband Doppler gradients. Follow-up was one to three months. RESULTS: An excellent correlation between transbanding systolic pressure gradient and degree of PAB constriction was encountered in the minipig study as well as in the human setting. No early or late deaths or reoperations occurred. Malfunction of the device was noted in three of 21 implanted devices. Two were related to surgically inflicted damage at implantation and one to an electronic problem that was fixed by resetting the control device. CONCLUSIONS: The device offers a Doppler-controllable adjustment of pulmonary blood flow. It permits controlled tightening and release of the band, which improves perioperative and postoperative courses and decreases surgical interventions to adjust tightness of the band. It allows a protracted occlusion protocol, which may provide the best effect on retraining the left ventricle.

Animals↗

[Scientific advice by the nationally competent authority and by the EMEA on the conduct of clinical trials].

Scientific advice for potential applicants for marketing authorization for medicinal products has been part of the tasks of the European Medicines Agency (EMEA) ever since its establishment in 1995, and has been of increasing significance. Based on Article 56(3) of Regulation (EC) No. 726/2004, this task is now the responsibility of an independent working group of the EMEA, the Scientific Advice Working Party (SAWP). National scientific and regulatory advice has also been part of the work of two national authorities in Germany, the Federal Agency for Medicinal Products and Medical Devices (BfArM) and the Paul Ehrlich Institute (PEI) for several years, but has gained in significance especially over the past 3 years. The basis for advice at a national level is Article 71c of the Law on Administrative Procedures (Verwaltungs-Verfahrensgesetz), the Drug Law, the Guidelines for the Evaluation of Medicinal Products (Arzneimittelprufrichtlinien), and relevant guidelines defining the scientific state of the art. A company developing medicinal products may consult the EMEA or the national authority at any time in order to obtain opinions on the investigations and studies on the pharmaceutical, preclinical and clinical development required for a particular stage of development. In this context, the focus is exclusively on the data required for the planned authorization and the assessment of the evaluation strategy suggested by the company itself. The agreement between the company and the regulatory authority prior to marketing approval is designed to achieve a more effective development of the product and to obtain a more rapid decision on a future authorization procedure. An important component of the scientific advice procedure is the discussion between the company and the agencies. The results of this oral exchange is always summarised in writing. Advice is available for all medicinal products, including "orphan drugs". At the European level, the authorization procedure is prepared with the EMEA which provides administrative and legal support, whereas the scientific opinion itself is elaborated by the members of SAWP, and is adopted by CHMP after a maximum of 3 months following the application. In addition to the written opinions elaborated by two members of SAWP, acting as coordinators, and the internal discussion, the exchange of positions within a "discussion meeting" is also an important part of the European procedure. Scientific advice is a fee-paying procedure, with certain exceptions. Experience from previous advice from the EMEA and the BfArM has shown a certain acceleration in subsequent procedures. This experience, however, also shows very clearly that it is the data actually established in the investigation, especially on efficacy and safety, which are important for a successful and fast approval procedure.

Advisory Committees↗

Percutaneous catheter thrombectomy device for acute pulmonary embolism: in vitro and in vivo testing.

PURPOSE: To evaluate a percutaneous pulmonary embolism (PE) thrombectomy catheter that aspirates, macerates, and removes thrombus. MATERIALS AND METHODS: Nine in vitro tests were performed by using porcine thrombi at a PE test station that provides continuous fluid output of 2 L/min at a pressure of 50 mmHg. Macroembolization was defined as embolized particles larger than 1.5 mm in dimension; microembolization was defined as particles that range in size from 0.1 to 1.5 mm. In static in vitro tests, researchers measured plasma-free hemoglobin levels in a 36-year-old man to assess mechanical hemolysis. Investigational review board approval and informed consent were obtained. The Department of Agriculture, Veterinary Bureau, Bern, Switzerland approved in vivo tests. Researchers investigated device effectiveness in 10 pigs that developed cardiogenic shock but survived massive PE after injection of two or three porcine thrombi into the external jugular vein via a surgically implanted 24-F sheath. Pulmonary angiography and hemodynamic measurements, including mean aortic and mean pulmonary artery pressure, heart rate, and mixed venous oxygen saturation, were obtained at baseline, after embolization, and after thrombectomy. Repeated-measures analysis of variance was performed to compare hemodynamic measurements at baseline, after embolization, and after thrombectomy. Cardiovascular structures were examined at necropsy for rupture, perforation, dissection, or hemorrhage. RESULTS: During a mean aspiration time of 69 seconds +/- 19, thrombi were completely extracted from 14-mm test tubes, with an aspirated fluid volume of 201 mL +/- 64. Although no macroembolization was observed, microembolization was quantified at 1.9 g +/- 1.3. Catheter aspiration was not associated with an increase in plasma-free hemoglobin. In 10 animals, aortic pressure increased from 52 mmHg +/- 24 before thrombectomy to 90 mmHg +/- 32 after thrombectomy, mixed venous oxygen saturation increased from 48% +/- 19% to 61% +/- 12%, pulmonary artery pressure decreased from 33 mmHg +/- 9 to 22 mmHg +/- 4, and heart rate decreased from 162 beats per minute +/- 24 to 114 beats per minute +/- 14. We did not observe macro- or microscopic damage to treated or untreated cardiovascular structures. CONCLUSION: The PE thrombectomy device was highly effective, facilitating rapid reversal of cardiogenic shock without device-related complications.

Acute Disease↗