At least 1,639 records · Page 91Linked to original sources

Colonoscopy in the office setting is safe, and financially sound ... for now.

PURPOSE: In 2000, the Centers for Medicare & Medicaid Services announced a plan to allow for enhanced reimbursement for office endoscopy. This change in reimbursement was phased in during three years. The purpose of this study was to evaluate the fiscal outcomes and quality measures in the first two and a one-half years of performing endoscopy in an office setting under the new Centers for Medicare & Medicaid Services guidelines. METHODS: The following financial parameters were gathered: number of endoscopies, expenses (divided into salaries and operational), net revenue, and margin for endoscopies performed in the office compared with the hospital. All endoscopies were performed by endoscopists with advanced training (gastroenterology fellowship or colon and rectal surgery residency). Monitoring equipment included continuous SaO2 and automated blood pressure in all patients and continuous electrocardiographic monitors in selected patients. Quality/safety data have been tracked in a prospective manner and include number of transfers to the hospital, perforations, bleeding requiring transfusion or hospitalization, and cardiorespiratory arrest. RESULTS: The financial outcomes are as follows: 13,285 endoscopies performed from the opening of the unit through December 2003; net revenue per case $504 per case; expense per case has dropped from $205 per case to $145 per case; the overall financial benefit of performing endoscopy in the office compared with the hospital was an additional $28 to $143 per case depending on the insurance carrier. The quality outcomes since inception of the unit include the following: 13,285 endoscopies; 0 hospital transfers, 0 cardiorespiratory arrests; 0 perforations; and 1 bleeding episode that required hospitalization. CONCLUSIONS: Endoscopy performed in the office setting is safe when done with appropriate monitoring and in the proper patient population. At the time of this study, office endoscopy also is financially rewarding but changes in Centers for Medicare & Medicaid Services reimbursement threaten the ability to retain any financial benefit.

Ambulatory Care↗

Dog colonoscopy model for predicting human colon absorption.

PURPOSE: This study was conducted to develop and validate a dog colon model that predicts colon permeability in humans. METHODS: The following compounds were studied: Class 1 highly soluble (HS)/highly permeable (HP): aminophylline, propranolol, CP-409092; Class 2 LS/HP: nifedipine; trovafloxacin, sertraline; Class 3 HS/LP: azithromycin, atenolol, CP-331684, CP-424391; Class 4 LS/LP: CJ-13610. Administration to dogs was made 30 cm cranial to the anal sphincter with a lubricated Schott Model VFS-5 flexible endoscope. The bioavailability of the compound following the colon administration in dogs, relative to the same formulation administered orally (relative bioavailability), was determined. RESULTS: Except for atenolol, a small hydrophillic molecule, the relative bioavailability from administration to the colon of the dog correlated well with the following compound properties: high solubility and high, passive permeability > high solubility, low permeability > low solubility, high, passive permeability approximately low solubility, low permeability. CONCLUSION: The dog colon model is proposed as a surrogate for human intubation studies when the controlled release candidate falls in BCS Classes 2 (LS/HP), 3 (HS/LP), and 4 (LS/LP). However, no human intubation or dog colon studies are required for Class 1 (HS/HP), as these compounds are likely to be well absorbed from the colon.

Administration, Oral↗

Indium 111-granulocyte scanning in the assessment of disease extent and disease activity in inflammatory bowel disease. A comparison with colonoscopy, histology, and fecal indium 111-granulocyte excretion.

Indium 111-leukocyte scanning has recently been introduced as a new method for imaging inflammatory bowel disease. The technique has recently been made more specific for acute inflammation by labeling a pure granulocyte fraction rather than the conventional mixed leukocyte preparation. We now report a prospective study comparing 111In-granulocyte scanning with endoscopy, histology, and fecal 111In-granulocyte excretion for the assessment of disease extent and severity in colonic inflammatory bowel disease. In 52 patients with Crohn's disease or ulcerative colitis, disease extent and severity were assessed macroscopically, histologically, or by scanning using a numerical grading system. Excellent correlations were found between both endoscopy and histology and 111In scans [r = 0.90 (endoscopy) and r = 0.90 (histology) for extent; r = 0.86 and r = 0.91 for disease activity]. Severity graded by scanning also showed a close correlation with fecal 111In-granulocyte excretion (r = 0.90). Indium 111-granulocyte scans are a rapid, accurate, noninvasive means of assessing both disease extent and severity of colonic involvement in inflammatory bowel disease.

Biopsy↗

MR colonoscopy at 3.0 T: comparison with 1.5 T in vivo and a colon model.

PURPOSE: Retrospectively, magnetic resonance (MR) colonography images obtained from a colon model and in routine examinations of patients screened for polyps were compared in terms of whether, and to what degree, image quality improved at a higher field strength of 3.0 T compared to 1.5 T. MATERIALS AND METHODS: One hundred twenty-eight MR colonography images from 40 patients, of whom 20 had each been scanned at 1.5 and 3.0 T, respectively, using a four-element phased-array torso coil, were compared. At both field strengths, imaging included T1-weighted fat-suppressed spoiled gradient-echo (T1-fs-GE), T2/T1-weighted fast imaging employing steady-state acquisition (FIESTA), and T2-weighted single-shot fast spin-echo (T2-SSFSE), with breath-hold technique. Using receiver operating characteristic analysis performed by seven readers, the three types of images from the colon model and from 20 patients each at 1.5 and 3.0 T were compared. While a time window of 20 s was allowed for picture assessment in a chance-generated succession of images on a monitor, image quality was rated with a score of 1-5 (1=very good; 5=very bad). Statistical significance was calculated with Mann-Whitney U test. RESULTS: At both field strengths, T2-SSFSE images received the best ratings, followed by FIESTA images (P=.001). Although, overall, the 3.0-T images obtained scores worse than those of the 1.5-T images, a better detection of phantom polyps was noted in the colon model (P=.001). CONCLUSION: Although MR colonography with the breath-hold technique using the same four-element phased-array coil at 3.0 and 1.5 T does not perform better at a higher field strength in general, an improved detection of small polyps may be obtained.

Colon↗

Multi-detector CT-colonography in inflammatory bowel disease: prospective analysis of CT-findings to high-resolution video colonoscopy.

AIM: Prospective analysis of multi-detector CT-colonography (MDCTC) in patients with inflammatory bowel disease (IBD) compared to high-resolution video-endoscopy (HRVC). MATERIALS AND METHODS: Twenty-one patients (mean age 49.6 years) with Crohn's disease or ulcerative colitis underwent MDCTC (Somatom Volume Zoom, Siemens, Erlangen; 1mm collimation, Pitch 8, 100 mAs, 120 kVp). HRVC was performed within 2 h after MDCTC. MDCTC was analyzed by two blinded readers. MDCTC-findings including bowel wall alterations and extraintestinal changes were compared to results of HRVC. RESULTS: Over-all-sensitivity was 100% for endoluminal lesions with correct diagnosis of two cancers. Acute and chronic IBD were correctly identified by MDCTC in 63.6%, and 100%, respectively, with a specificity of 75%, and 100%. Sensitivity, specificity, positive and negative predictive values of MDCTC for diagnosis of acute and chronic disease were best for chronic disease. Sensitivity was worst for acute ulcerative colitis and specificity was worst for acute Crohn's disease. Haustral loss was seen only in ulcerative colitis. Pseudopolyps and fistulae were findings exclusive to Crohn's disease. Particularly extraintestinal findings as increased vascularization and local lymphadenopathy correlated well with endoscopic definition of acute disease. Because of the possibly more vulnerable colonic wall in acute inflammatory bowel disease, the air inflation for MDCTC should be performed most carefully to avoid any risk of colonic perforation. CONCLUSION: MDCTC may help to distinguish between patients with acute and chronic IBD. Especially extraintestinal complications, tumorous as well as pseudo-tumorous lesions can be detected with high sensitivity and specificity.

Adult↗