Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Cardiac Output”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91Linked to original sources

Cardiac output increases prior to development of pulmonary edema after re-expansion of spontaneous pneumothorax.

Pulmonary edema following reexpansion of spontaneous pneumothorax is an uncommon complication. The underlying mechanism of this condition is unclear. We report the hemodynamic characteristics in a series of 7 male patients with spontaneous large (>50%) pneumothoraces of > or = 24 h and correlate the changes with reexpansion pulmonary edema (REPE). A pulmonary artery floatation catheter was inserted and hemodynamic data were obtained before therapeutic chest tube insertion, 1 h after chest tube insertion and the following day. Four (57%) patients developed REPE. There was a tendency for larger pneumothorax to develop REPE. Capillary wedge pressure did not change significantly 1 h after the insertion of chest tube in all our patients. Cardiac output increased significantly in patients who developed REPE compared to those who did not (+ 1.06 l/min vs -0.27 l/min; P = 0.03) 1 h after insertion of chest tube. One patient did not develop pulmonary edema despite having a large (> 80%) pneumothorax. His cardiac output did not rise 1 h after chest tube insertion. REPE is not an uncommon complication following chest tube drainage in patients with large and long-standing pneumothorax. The increase in cardiac output after chest tube insertion may be associated with subsequent development of REPE.

Adult↗

Noninvasive cardiac output: simultaneous comparison of two different methods with thermodilution.

The authors attempted to simultaneously measure cardiac output by thermodilution (COtd), thoracic bioimpedance (CObi), and suprasternal Doppler ultrasound (COdopp) in 68 patients. Subgroups separately compared included patients whose lungs were mechanically ventilated, patients undergoing cardiac surgery, aortic surgery, patients with dysrhythmias, and patients with sepsis. The authors also studied the value of the ventricular ejection time (VET) in evaluating the agreement of CObi and COdopp with COtd. Simultaneous CObi and COtd were available in a total of 56 patients (416 data sets) with an overall correlation coefficient r = 0.61, regression slope (m) of 0.52, intercept (y) of 2.46, and mean (CObi-COtd) difference (bias) of -0.67 +/- 1.72 (SD) l/min. Simultaneous COdopp and COtd were available in 59 patients (446 data sets) with an overall r = 0.51, m of 0.53, y of 2.05, and bias of -0.79 +/- 1.95 l/min. CObi agreed most closely with COtd in patients whose lungs were mechanically ventilated, who had not undergone cardiac or aortic surgery, and with VET difference less than 40 ms (16 patients, 99 data sets; r = 0.74; m = 0.97; y = 0.15; bias = -0.02 +/- 1.53 l/min). COdopp agreed most closely with COtd in patients whose lungs were mechanically ventilated, who had not undergone cardiac or aortic surgery, and in sinus rhythm with VET difference less than 40 ms (10 patients, 45 data sets; r = 0.82; m = 0.98; y = -0.07; bias = -0.82 +/-1.03 l/min). VET by radial artery can help evaluate the reliability of CObi and COdopp.

Aorta↗

[Reproductibility of the true measurement of blood volume, cardiac output, mean pulmonary circulation time and pulmonary blood volume by radiocardiography].

Radiocardiography provides a simple method of measurement of blood volume, cardiac output, mean pulmonary circulation time, and pulmonary blood volume. The use of a computer allows the results to produced immediately provided that the circulating blood volume is measured during the test anpd that the radiocardiographic tracing is analysed by an entirely automatic method. The reproducibity of the results given by this automatic method has been studied in 35 patients, two measurements being made at 20 minute intervals. The standard deviation of the percentage difference between consecutive measurements was 5.8% for the blood volume, 10.4% for the cardiac output, 8.8% for the mean pulmonary circulation time, and 9.7% for the pulmonary blood volume.

Adolescent↗

Blood flow in the common carotid artery in term and preterm infants: reproducibility and relation to cardiac output.

AIM: To assess the reproducibility of, and determine normative data for, flow volume measurements from the right common carotid artery (CCA) and its relation to left ventricular output (LVO) in stable term and preterm babies using Doppler ultrasound. METHODS: Right CCA flow volume was measured using a near focus, high frequency transducer by obtaining intensity weighted mean velocity and right CCA diameter. LVO was determined using standard Doppler techniques. Reproducibility studies were performed on 30 newborn infants by two observers. Normative data were obtained from 40 spontaneously breathing preterm babies and 21 term babies. RESULTS: The intraobserver coefficient of variation for CCA flow measurements was 10.5% for observer 1 and 15.4% for observer 2, whereas the interobserver coefficient of variation was 16.4%. In term and preterm infants, right CCA flow was about 20 ml/kg/min, accounting for 11% of cardiac output. Among the preterm infants, there was a positive correlation of right CCA flow with gestation (r = 0.61, p<0.001), weight (r = 0.64, p<0.001), and LVO (r = 0.59, p<0.001). Right CCA diameter also increased with weight (r = 0.63, p<0.001) and gestation (r = 0.58, p<0.001). The proportion of LVO distributed to the right CCA did not increase with gestation, nor did the right CCA flow per kg body weight. CONCLUSIONS: It is possible to perform reproducible measurements of flow volume in the CCA of newborn infants. In stable, spontaneously breathing babies, both cardiac output and carotid flow increased with gestation and body weight. The proportion of cardiac output distributed to the right CCA remained relatively constant across gestation.

Birth Weight↗

Continuous positive pressure ventilation during epidural blockade--effects on cardiac output distribution.

BACKGROUND: It has been shown that when cardiac output (CO) decreases during continuous positive pressure ventilation (CPPV), its regional distribution adapts with a favouring of vital organs. Does epidural blockade modify this adaptation? METHODS: Regional blood flows were assessed by the microsphere technique (15 microm) in 17 anaesthetised pigs during spontaneous breathing and CPPV with 8 cm H2O end-expiratory pressure (CPPV8) before and after epidural blockade. The block was induced at either the Th6-7 (Thep) or the L6-S1 (Lep) level with 1 ml of lidocaine 40 mg x ml(-1). RESULTS: When Lep was combined with CPPV8, mean arterial pressure and CO decreased significantly, and they decreased even more when combined with Thep. In contrast, the relative perfusion of the central nervous system, heart and kidneys remained stable during the four conditions studied. The adrenal perfusion during CPPV8 was obviated by epidural blockade. The absolute and relative perfusion of the skeletal muscle decreased during epidural blockade. The administered doses of epidural lidocaine did not affect blood flow in the spinal cord. CONCLUSIONS: The locally mediated nutritive vasoregulation of vital organs outweighed the sympathetic blockade induced by epidural blockade. During Thep blockade the animals were less capable of responding to the haemodynamic changes induced by CPPV8, probably due to the blockade of the cardiac part of the sympathetic nervous system.

Adrenal Glands↗

Effect of atrial septal defect created during balloon mitral valvuloplasty on calculation of cardiac output and mitral valve area.

We studied the effect of atrial septal defect (ASD), produced during transseptal puncture, on estimation of cardiac output (CO) and mitral valve area (MVA), after successful balloon mitral valvuloplasty (BMV) using the Inoue balloon in 20 patients. Oximetry run, pressure gradients, thermodilution CO and MVA were measured initially while temporarily occluding the ASD by partially inflating the Inoue balloon catheter. Measurements were repeated after withdrawing the balloon catheter into the right atrium. Post-BMV cardiac output and MVA were similar in both the situations (4.52 +/- 1.37 L/min vs 4.50 +/- 1.19 L/min; 1.89 +/- 0.4 cm2 vs 1.93 +/- 0.38 cm2 respectively, p = ns). Only 2 patients showed a step up at atrial level on oximetry (9% and 16% respectively) but did not have significantly different CO or MVA, both with ASD occluded or otherwise. We conclude that the magnitude of ASD created during BMV by Inoue balloon technique is small and does not significantly affect the estimation of CO or MVA if the septal puncture is done in the fossa ovalis area.

Adolescent↗

Doppler echocardiography for the estimation of cardiac output with exercise.

Insights into both normal and pathological cardiac responses to exercise have been hampered by lack of a safe, accurate, feasible means of estimating cardiac output (Q) during high-intensity and maximal exercise. Doppler ultrasound noninvasively measures blood velocity as it exits the heart and can be performed during exhaustive exercise without interference of the subject or need for steady state. From the product of aortic blood velocity and cross-sectional area of the aorta, stroke volume (SV) can be calculated. Despite these advantages of the Doppler technique, a number of potential sources of error have raised concern regarding the accuracy of this method. These include transducer angulation, change in aortic cross-sectional area during exercise, turbulence and alteration of a flat velocity profile in the aorta with increased Q, and uncertainties regarding the proper location for measurement of aortic outflow area. The magnitude of the influence of these potentially confounding variables on the accuracy of SV measurements determined by the Doppler technique is unknown. Estimates of both construct and concurrent validity suggest that the overall error may be small. Test-retest studies have indicated a high level of reliability with this technique.

Aorta↗

Thermal dilution measurement of cardiac output in dogs using an analog computer.

Thermal dilution cardiac output determinations in dogs were compared to simultaneously performed Fick oxygen measurements. The purpose of this study was to validate in dog experiments a method for thermal dilution measurement which employs a double-thermistor catheter combined with an automatic computer as described by Olsson et al. Dilution and injectate temperature are entered directly into the calculation. The method does not employ logarithmic extrapolation, integration of the dilution signal being terminated when a preset cut-off level is reached. Errors due to recirculation, thermal capacitance of the right heart and heat exchange with the catheter's dead space require the use of an empirically derived correction factor, which in dogs was found to be significantly different from the factor used for human thermal dilution curves. With the appropriate cut-off level and correction factor a good agreement was found between the results of the thermal dilution and the Fick method. The regression equation for 47 experiments was found to be COtd = 0.95 COFick + 0.08; the correlation coefficient was 0.94.

Animals↗

Protection of the ischaemic myocardium by L-propionylcarnitine: effects on the recovery of cardiac output after ischaemia and reperfusion, carnitine transport, and fatty acid oxidation.

The effects of L-propionylcarnitine on the recovery of cardiac contractile performance after global ischaemia and reperfusion were studied in isolated perfused rat hearts. The addition of either 5.5 or 11 mmol X litre-1 L-propionylcarnitine significantly improved the recovery of cardiac output, left ventricular pressure, and dP/dt after 90 min of ischaemia and 15 min of reperfusion. Myocardial adenosine triphosphate and creatine phosphate concentrations were significantly higher in the L-propionylcarnitine treated hearts than in controls, but the concentrations of long chain acyl carnitine and coenzyme A were unaffected. The protecting effects of L-propionylcarnitine were compared with those of L-carnitine and L-acetylcarnitine. A 11 mmol X litre-1 dose of L-propionylcarnitine and L-acetylcarnitine significantly improved the recovery of cardiac output after 90 min of ischaemia and 15 min of reperfusion, but L-carnitine did not. L-Propionylcarnitine was the most protective agent. The effects of these derivatives on L-3H-carnitine transport and 14C-palmitate oxidation were also measured. All of these derivatives competitively inhibited L-3H-carnitine transport in isolated cardiac myocytes, but L-propionylcarnitine was the most potent. Carnitine and L-propionylcarnitine stimulated palmitate oxidation in the homogenate, whereas L-acetylcarnitine inhibited it. In myocytes only L-propionylcarnitine affected palmitate oxidation. These data show that L-propionylcarnitine protects the ischaemic myocardium. Its protection is greater than that for L-carnitine or L-acetylcarnitine, and the difference in effectiveness may relate to the rate of transport into the cells and the effects on fatty acid utilisation.

Acetylcarnitine↗

An on line technique to detect cardiac output variations and cardiovascular performances during abdominal aortic surgery.

Cardiac output (CO) is a parameter usually requested to assess hemo dynamic status of patient and efficacy of therapy especially in critically ill patients. This paper, in line with other research activities and new market availability, intends to correlate a parameter derived from data already acquired in standard patient monitoring (systemic arterial pressure--Pas) in order to identify CO trends and, more generally, to obtain information on the efficiency of cardiovascular system of the patient in examination. Attention has been focussed on patients undergoing abdominal aneurysm aortic (AAA) surgery with combined anaesthesia (epidural and light general). Awake correlation was found between maximum value of Pas time derivative, max (dPas/dt), and CO measured with thermodilution method on 56 measurements on 10 patients. To evaluate further diagnostic capability of max (dPas/dt), we compare its trend with other parameters but no statistical significant results have been obtained. Therefore the target parameter can be profitably used in the examined patients to monitor CO trend and, in correlation with other parameters, as a sign of efficiency of the cardio circulatory system.

Aged↗

The precision of a special purpose analog computer in clinical cardiac output determination.

Three hundred dye-dilution curves taken during our first year of clinical experience with the Waters CO-4 cardiac output computer were analyzed to estimate the errors involved in its use. Provided that calibration is accurate and 5.0 mg of dye are injected for each curve, then the percentage standard deviation of measurement using this computer is about 8.7%. Included in this are the errors inherent in the computer, errors due to baseline drift, errors in the injection of dye and acutal variation of cardiac output over a series of successive determinations. The size of this error is comparable to that involved in manual calculation. The mean value of five successive curves will be within 10% of the real value in 99 cases out of 100. Advances in methodology and equipment are discussed which make calibration simpler and more accurate, and which should also improve the quality of computer determination. A list of suggestions is given to minimize the errors involved in the clinical use of this equipment.

Cardiac Output↗

The consistency of cardiac output measurement (CO2 rebreathe) in children during exercise.

Exercise cardiac output (Q) was determined using the CO2 rebreathing equilibrium method. Five repeat tests in 12 boys and two tests over a 4 month interval in 47 boys were performed. Regression equations to predict Q from VO2 were in close agreement with dye dilution studies in boys (Eriksson and Koch 1973). Group mean data were reproducible from trial to trial. The day-to-day variability of Q, with a coefficient of variation of 7-8%, was found to be higher than when the CO2 method has been applied in adults. This greater variability was related, in part, to a larger biological variation in children as depicted in such relatively simple measures as submaximal exercise heart rate. The larger variability was also related to inaccuracies in the methods of PaCO2 estimation in children. Estimation from end-tidal CO2 concentrations requires further research to establish a correction for the alveolar-arterial gradient during exercise in children. Estimation of the child's dead space in exercise, with subsequent derivation of PaCO2 from the Bohr equation, also could be improved. Nevertheless, Q estimates in children exercising above VO2 1.01 X min-1 showed a day-to-day and long term stability acceptable for use in research and clinical studies.

Adolescent↗

Noninvasive estimation of cardiac output with nonprescribed breathing.

A noninvasive method to estimate cardiac output Q without special patient cooperation was developed by modifying a previous acetylene-helium (C2H2-He) rebreathing technique (ART). Estimation of Q using ART is based on a single-compartment model that is valid only under prescribed breathing; e.g., fast, deep breathing, and emptying of the rebreathing bag on each breath. To make the ART less dependent on subject cooperation, a more sophisticated mathematical model and estimation method are needed. For this purpose, we modeled the C2H2 and He concentration dynamics at the mouth over successive breaths using a multi-compartment model. This model takes into account the effects of breathing pattern, compartmental volumes, and gas solubility. From computer simulations and sensitivity analysis, we found that Q could be estimated from the available data with adequate precision. Our model and estimation method were tested on a group of six normal adult subjects, at rest and during submaximal exercise (75 watts). Estimates of Q from our new method (6.5 +/- 0.4 L/min at rest, 12.5 +/- 0.4 L/min at 75 watts) were in agreement with those obtained using a previous ART (7.0 +/- 0.3 L/min at rest, 12.6 +/- 0.5 L/min at 75 watts). We conclude that this approach promises to provide reliable estimates of Q in patients (e.g., children and elderly), at rest and during exercise, without the need of prescribed breathing patterns or changes in rebreathing bag volume.

Acetylene↗

After effects of chronic hypoxia on cardiac output and muscle blood flow at rest and exercise.

Cardiac output (Q, by N2-CO2 rebreathing) and limb muscle blood flow (qm, from 133Xe clearance) were determined in eight male subjects at rest and during cycloergometric loads immediately before and 12 days after return from the 1981 Swiss Lhotse Shar (8,398 m) Expedition. Compared to control conditions, after exposure to hypoxia: 1) Q was unchanged at rest and at 75 watts (W) but was 18% less (P less than 0.01) at 150 W with constant heart rate (approximately 140 beats X min-1); 2) qm in the vastus lateralis was identical at rest but 26% and 39% less (P less than 0.05 and P less than 0.001, respectively) at two submaximal leg work loads (75 and 125 W); 3) qm in the biceps at 50 W was 34% less (P less than 0.01); 4) hemoglobin flow (QHb and qmHb), similarly to blood flow (Q and qm), was significantly reduced; 5) the qm adjustment rate, measured from the time required to attain a new steady state upon a square wave change of work load starting from rest, was slower, particularly at the lower work loads. From the above results as well as from corresponding morphometric findings showing in the same subjects: 1) a decrease of the ratio between fiber section and number of capillaries and 2) a rise of the mitochondrial to fiber volume ratio, it is concluded that during altitude acclimatization peripheral O2 delivery becomes more efficient.

Acclimatization↗

Comparison of bioimpedance and Doppler ultrasound cardiac output in CAPD patients.

The reproducibility and reliability of cardiac output (CO) measurement by transthoracic electrical bioimpedance (TEB) and dual beam Doppler ultrasound methods were compared in 9 uremic patients during treatment with continuous ambulatory peritoneal dialysis (CAPD). CO was measured simultaneously by each method during supine rest and 70 degree passive head-up tilt on two separate days. The effect on CO after the infusion of dialysate was also studied on day 1. CO, stroke volume (SV) and heart rate (HR) measurements were reproducible by each method. The median day to day differences (95% confidence intervals) in CO and SV were 0.6 (-0.3, 1.8) l/min and 10 (-1.5, 24.5) ml for TEB and 0.7 (-0.5, 2.2) l/min and 13 (-1.0, 30.5) ml for Doppler at supine rest; 0.4 (-0.2, 0.9) l/min and 11 (-0.5, 19.0) ml for TEB and 0.5 (-0.3, 1.2) l/min and 8 (-5.0, 16.0) ml for Doppler during tilt (p > 0.05 in each case). Data were unobtainable by TEB at five time points while none were lost by Doppler. This is due to incorrect HR or poor quality signals detected by TEB. CO and SV measured by Doppler were higher than that by TEB during supine rest (p < or = 0.01) but not during passive tilt. As a result, there was significant change (p < or = 0.01) in CO and SV from supine to tilt measured by Doppler but not by TEB. Neither TEB nor Doppler detected significant change (p > 0.05) in CO or SV after the infusion of dialysate, in either the supine or tilt positions.(ABSTRACT TRUNCATED AT 250 WORDS)

Cardiac Output↗

Quantification of mitral regurgitation by automated cardiac output measurement: experimental and clinical validation.

OBJECTIVES: To develop and validate an automated noninvasive method to quantify mitral regurgitation. BACKGROUND: Automated cardiac output measurement (ACM), which integrates digital color Doppler velocities in space and in time, has been validated for the left ventricular (LV) outflow tract but has not been tested for the LV inflow tract or to assess mitral regurgitation (MR). METHODS: First, to validate ACM against a gold standard (ultrasonic flow meter), 8 dogs were studied at 40 different stages of cardiac output (CO). Second, to compare ACM to the LV outflow (ACMa) and inflow (ACMm) tracts, 50 normal volunteers without MR or aortic regurgitation (44+/-5 years, 31 male) were studied. Third, to compare ACM with the standard pulsed Doppler-two-dimensional echocardiographic (PD-2D) method for quantification of MR, 51 patients (61+/-14 years, 30 male) with MR were studied. RESULTS: In the canine studies, CO by ACM (1.32+/-0.3 liter/min, y) and flow meter (1.35+/-0.3 liter/min, x) showed good correlation (r=0.95, y=0.89x+0.11) and agreement (deltaCO(y-x)=0.03+/-0.08 [mean+/-SD] liter/min). In the normal subjects, CO measured by ACMm agreed with CO by ACMa (r=0.90, p < 0.0001, deltaCO=-0.09+/-0.42 liter/min), PD (r=0.87, p < 0.0001, deltaCO=0.12+/-0.49 liter/min) and 2D (r=0.84, p < 0.0001, deltaCO=-0.16+/-0.48 liter/min). In the patients, mitral regurgitant volume (MRV) by ACMm-ACMa agreed with PD-2D (r= 0.88, y=0.88x+6.6, p < 0.0001, deltaMRV=2.68+/-9.7 ml). CONCLUSIONS: We determined that ACM is a feasible new method for quantifying LV outflow and inflow volume to measure MRV and that ACM automatically performs calculations that are equivalent to more time-consuming Doppler and 2D measurements. Additionally, ACM should improve MR quantification in routine clinical practice.

Adult↗

High-output cardiac failure as a presenting symptom of plasma cell leukemia.

A patient presented with high-output cardiac failure and was found to have plasma-cell leukemia. No cause for the cardiac failure was found, and there was no response to treatment with diuretics and thiamine. Chemotherapy for the leukemia resulted in resolution of the cardiac failure, suggesting that the latter was caused by the leukemia--a hitherto unreported association.

Antineoplastic Combined Chemotherapy Protocols↗