Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ARTIFICIAL LIMBS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91Linked to original sources

[Lower limb amputations caused by tumours and prosthetic rehabilitation in Croatia from 2000 to 2004].

During the period of five years (2000-2004) we monitored 46 patients (25 males and 21 females) who were admitted to Clinical Institute for Rehabilitation and Orthopaedic Aids in Zagreb for the first prosthetic rehabilitation following the lower limb amputation which was caused by a tumour. The average age of patients was 51 +/- 17.11 years. According to the pathohistological diagnosis the most common cause of lower limb amputations was osteosarcoma. According to the level of amputation the most frequent was trans-femoral amputation (50%) and the least frequent was knee disarticulation (8.7%). The average number of days from the amputation to the beginning of prosthetic rehabilitation was 108 +/- 67.05. At the time of admission 15.2% of patients had local complications of the stump and 34.8% of patients complained of phantom pain. The average number of days of prosthetic rehabilitation was 35 +/- 7.94. The medium daily use of the prosthesis was 5 hours and the medium walking speed was 12 sec/10 m. At the time of admission for the prosthetic rehabilitation 10.9% of patients used a wheelchair, 8.7% walked with a walker and others with two crutches. At the time of discharge 89.1% of patients were able to walk with a prosthesis and two crutches, 4.4% with one crutch and 6.5% were able to walk without crutches. We can be satisfied with the results of prosthetic rehabilitation because patients regained mobility and full independence in performing their daily activities.

Adolescent↗

[Longitudinal study of vascular patients with standardized Brückner distal limb amputation].

OBJECTIVE: The present study aims to evaluate early and late results after standardized below-knee amputation according to Brückner in vascular patients. PATIENTS AND METHODS: During the period 1982 to 1989 72 patients with occlusive arterial disease stage IV underwent below-knee amputation at an average age of 69.7 years. 38 of the amputees could be re-investigated at the end of 1991 after an average follow-up of 5.3 years. Evaluation criteria consisted of wound healing, knee joint preservation, prosthetic fitting, stump appearance, gait capacity or ambulation, the need for assistance by another person and patients own valuation. Accordingly, rehabilitation level was classified to be good, satisfying or dissatisfying. RESULTS: Knee joint preservation rate amounted to 91.7% (66 patients). Postsurgical prosthetic fitting could be achieved in 55 amputees (76.4%). All the 38 re-investigated stumps were inapparent. 27 of the patients (71.1%) showed good and 7 patients (18.4%) satisfying rehabilitation, whereas the rehabilitation level was dissatisfying in 4 cases (10.5%). This objective evaluation was affirmed by patients own estimation: 33 amputees (86.6%) would again agree to the operation. CONCLUSIONS: Early as well as late results in this series indicate that the standardized below-knee amputation according to Brückner promises high rates of healing, knee joint preservation and thus successful rehabilitation in patients with occlusive arterial disease.

Adult↗

The long-term outcome of upper limb amputees treated at a rehabilitation centre in Sydney, Australia.

A follow-up study by questionnaire or interview has been made of the 27 respondents of 41 upper limb amputees (66%) treated at the Royal South Sydney Hospital between 1981 and 1990. Prosthetic use of 8 h/day or more was 37% and occasional use was 18.5%. The prosthetic users were more likely to be distal amputees. The reason for the low level of prosthetic use is not known. The majority of non-users discarded prostheses after leaving their rehabilitation programme. Occupational changes were made by 72% of the amputees. The unemployment rate at follow-up was similar to the rest of the community, which is a better outcome than 25 years ago. Activities of daily living had been affected in all patients, but to a lesser extent in prosthetic users. Leisure pursuits were changed in 70% of patients, with these activities being more sedentary and indoor in nature. Of the 18 car drivers, 15 drove automatic cars with modifications. Phantom pain was experienced by 16 of the respondents (59%) and stump pain was experienced by seven. Only 26% used medication or alcohol for the pain. Pain did not affect prosthetic use or functional ability.

Activities of Daily Living↗

Transcutaneous oxygen pressure. An effective measure for prosthesis fitting on below-knee amputations.

After amputation for arterial occlusive disease of the lower limbs, healing and local adaptation to a prosthesis depend on the oxygen ratio in the tissue. Transcutaneous oxygen tension (TcPO2) is a noninvasive microcirculatory exploration. Forty six below-knee stumps were selected without any prosthetic problem excepting vascular, with a follow-up mean duration of 23 months. They were classified into different prosthetic categories. The first was the worst because it required further amputation on the thigh and the fourth the best, which displayed complete adaptation to a socket contact. These groups were related to their TcPO2 values on the anterior and exterior face of the stumps in both reclined and seated positions. It seems that it is impossible to achieve healing when the TcPO2 value is lower than 15 mm Hg in lying position. However, healing is possible above 20 mm Hg but socket contact is not possible when TcPO2 values are under 40 mm Hg. When TcPO2 values are above 40 mm Hg, a good prosthesis fitting is possible when no problems are encountered other than vascular ones.

Aged↗

A CAD CAM method for custom below-knee sockets.

The purpose of this investigation was to develop a numerical method for fabricating prosthetic sockets for below-knee amputees. An optical/laser digitiser scans an amputee's stump and collects three dimensional numerical data describing the surface of the limb and describing specific modification site locations. The numerical data from the laser camera representing the stump and modification sites are altered by the prosthetist using a custom computer aided design software system running on a personal computer. Using the altered numerical data a programme is created for a high resolution numerically controlled milling machine and a mould is made. The prosthetist then fabricates a socket. While the system has been tested with below-knee amputees it has been designed for application in most areas of prosthetics and orthotics. Utilising this method 15 patients were fitted. All patients subjectively stated that their "computer designed" socket fitted better than their conventionally made socket. As the research progressed and experience was gained with the system patients were normally fitted with the first socket iteration. The system overcomes five limitations existing with some of the other numerical systems: 1) accurate high resolution surface topography, 2) specific identification of subject modification sites, 3) flexible, user friendly software, 4) high resolution numerically controlled milling, and 5) integrated expansion to other prosthetic and orthotic areas.

Artificial Limbs↗

Amputation alternatives in the lower limb, stressing combined management of the traumatized extremity.

A methods approach for the care of the traumatic lower extremity amputee is presented, emphasizing joint surgical approach, specifics of management, ideal amputation levels, and functional rehabilitation. The role of the plastic surgeon with an interest in free flaps is ever increasing and has elevated the level and quality of traumatic extremity amputation. Therefore, an understanding by the plastic surgeon of the orthopedic, prosthetic, functional, and rehabilitation principles becomes as important as the orthopedic surgeon's appreciation of current microvascular reconstruction potential. Fortunately, large numbers of traumatic amputees are not available for study in the civilian population. With better-quality extremity salvage by free flap coverage, this number is decreasing. However, the problem will never be eliminated and efforts to produce the best possible amputation must be expended by the best techniques and personnel. Prosthetic management continues to develop with exciting innovations on the horizon. Currently, the modular concept of prosthetic design (Fig. 26) is a practical, cosmetic standard. Newer space-age materials and design changes should facilitate the functional potential of the traumatic amputee. Characteristics of traumatic lower extremity amputees are youth, immaturity, arrogance, and psychological instability, but they are usually cooperative following the initial shock and reality of the situation. These young people deserve our best efforts to allow them to become integrated into society and continue an active life, albeit passive or active (Fig. 27).

Amputation, Surgical↗

Rehabilitation after lower limb amputation: a comparative study of above-knee, through-knee and Gritti-Stokes amputations.

A study of 169 unilateral amputees under three Disablement Services Centres was performed. The study comprised 88 above-knee, 54 through-knee and 27 Gritti-Stokes amputations. Satisfactory rehabilitation occurred in 33 per cent of above-knee, 62 per cent of through-knee and 44 per cent of Gritti-Stokes patients (56 per cent overall). The better rehabilitation of through-knee versus above-knee amputees (P less than 0.02) was also found in a group of patients matched for comparable age and duration of amputation as well as in a group of age-matched vascular amputees. Through-knee amputees relied significantly less on wheelchairs than above-knee (P = 0.016) and Gritti-Stokes (P = 0.05) amputees. The prosthesis used for the through-knee and Gritti-Stokes amputations was considered unsightly in 50 per cent of cases (versus 31 per cent for the above-knee prosthesis). The superior rehabilitation with through-knee amputations should prompt us to improve both our technique for this amputation and the prostheses currently available. A through-knee amputation should be performed in preference to an above-knee amputation in the case where either is surgically possible, and a below-knee amputation not feasible.

Adult↗

Predictive factors of functional ability after lower-limb amputation.

Functional ability and accommodation situation were studied by personal interview and examination of 125 surviving lower-limb amputees after one postoperative year. Among ten independent variables studied by multiple linear regression analysis, an unfavourable association was found between increasing age and the following aspects of physical function: walking distance (P less than 0.001), walking time (P less than 0.001), amount of outdoor walking outdoors (P less than 0.001), increased need for aids to ambulation (P less than 0.01), use of a prosthesis (P less than 0.05). Using a partial correlation coefficient analysis of functional ability and accommodation situation, with adjustment for age, the time lag between surgery and prosthetic fitting, and the occurrence of cerebrovascular disease displayed a similar unfavourable association with prosthetic usage. In the group of BK (below-knee) amputees the length of the stump had a significant favourable relationship with walking distance (P less than 0.01). In the male group of vascular BK amputees, smoking had an unfavourable association with walking distance (P less than 0.01), ability to walk outdoors (P less than 0.01) and walking time (P less than 0.05). None of the variables showed any significant relationship with the postoperative accommodation situation.

Adolescent↗

Gait recovery pattern of unilateral lower limb amputees during rehabilitation.

The aim of this study was to determine the rate at which gait recovery as measured by temporal distance factors (velocity and symmetry) occurs in unilateral lower limb amputees. A microcomputer foot switch system was used to record the gait patterns of twenty subjects, mean age 65.1 years. The initial measurement was taken when the subject was capable of walking 6 metres with an interim prosthesis within the parallel bars. The patient sample as a whole was analyzed and subjects were further divided into four groups, depending on ambulatory aid required at discharge. Group A, n = 3 used no aid, Group B, n = 5 used a single stick, Group C, n = 6 used 2 single sticks and Group D, n = 5 required frames. A one way analysis of variance (F = 4.55, p = 0.02) showed a significant difference between the Groups, (A and D, B and D, C and D). The major velocity increase occurs within the first 30 days of the gait training programme. Overall about 55% increase in velocity can be expected within the first fifteen day period followed by an additional 30% between days 15-30. A moderately strong correlation (r = 0.78) was found between initial and discharge velocity. The correlation between initial and discharge symmetry was weaker (r = 0.50).

Adult↗

Balance confidence among people with lower-limb amputations.

BACKGROUND AND PURPOSE: Confidence in a person's balance has been shown to be an important predictor of social activity among people with lower-limb amputations. The purposes of this study were to describe confidence in balance among people with transtibial or transfemoral lower-limb amputations and to compare people whose amputations were due to vascular and nonvascular causes. SUBJECTS AND METHODS: A survey of a sample of 435 community-dwelling individuals from 2 regional clinics was conducted. The sample consisted of people with unilateral transfemoral (26.7%) and transtibial (73.3%) amputations who lost their limb for vascular (53%) and nonvascular (47%) reasons. The mean age of the primarily male (71%) sample was 62.0 years (SD=15.7). RESULTS: Mean scores, using the Activities-specific Balance Confidence (ABC) Scale, were 63.8 for the total sample, 54.1 for the subjects with amputations due to vascular reasons, and 74.7 for the subjects with amputations due to nonvascular reasons. Given a maximum possible ABC Scale score of 100, the results suggest that confidence was low. A difference between the subjects with amputations due to vascular reasons and those with amputations due to nonvascular reasons was observed over each item of the ABC Scale. Variables that were statistically related to balance confidence included age, sex, etiology, mobility device use, the need to concentrate while walking, limitations in activities of daily living, depression, and fear of falling. DISCUSSION AND CONCLUSION: Balance confidence scores among the study sample were low when compared with values previously reported by other researchers. Confidence was particularly low among individuals who had their amputation for vascular reasons. Balance confidence might be an important area of clinical concern.

Accidental Falls↗

The geometric design of micromachined silicon sieve electrodes influences functional nerve regeneration.

A neural interface could be used to control a limb prosthesis. Such an interface can be created by facilitating axonal regeneration through a sieve electrode and then register nerve signals intended to control the prosthesis. A key question is how to design the electrodes to ensure the best possible regeneration. Our previous studies have indicated that regeneration can be achieved using electrodes with square-shaped, 100 x 100 microm, via holes (holes that axons will regenerate through). Other reports have indicated a suitable range of these holes between 40 and 65 microm. In the present study we used silicon sieve electrodes with via holes of either 30 or 90 microm. The transparency, i.e. the percentage of the total via hole area, of these electrodes was either 20 or 30%. The electrodes were inserted into a silicone chamber which was used to bridge a gap in a rat sciatic nerve. After 12 weeks of nerve regeneration electrodes with a hole size of 30 microm and a 30% transparency had the most favourable result as judged by the regained gastrocnemius muscle force and the formation of reactive tissue inside the chamber. The sieve electrode transparency is crucial for ensuring regeneration.

Animals↗

The Prosthetic Upper Extremity Functional Index: development and reliability testing of a new functional status questionnaire for children who use upper extremity prostheses.

The Prosthetic Upper Extremity Functional Index (PUFI) was developed by the authors' clinical research group to evaluate the extent to which a child actually uses a prosthetic limb for daily activities, the comparative ease of task performance with and without the prosthesis, and its perceived usefulness. The PUFI's test-retest and interrater reliability were evaluated with 24 children. Intraclass coefficients (ICCs) were calculated for each of four subscales of the PUFI--specifically, method of performance, ease of prosthetic use, usefulness of the prosthesis, and ease of performance without the prosthesis. The ICCs were greater than 0.65, indicating good test-retest reliability for the older-child respondents (n = 10) and fair to good reliability (ICCs, 0.40 to 0.84) for the parent respondents overall (n= 21). Interrater (child-parent) reliability was lower, with ICCs from 0.30 to 0.77. This finding was not unexpected, since a child and parent may rate in the context of different functional environments. The prosthesis was used 53% of the time by older children and more than 75% of the time by younger children. The results provide evidence that the PUFI has good test-retest reliability overall as a measure of a child's ability to perform upper extremity activities with a prosthesis.

Activities of Daily Living↗

Discharge destination after dysvascular lower-limb amputations.

OBJECTIVE: To examine postacute care rehabilitation services use after dysvascular amputation. DESIGN: State-maintained hospital discharge data from the Maryland Health Services Cost Review Commission were analyzed. SETTING: Maryland statewide hospital discharge database. PARTICIPANTS: Persons discharged from nonfederal acute care hospitals from 1986 to 1997 with a procedure code for lower-limb amputation (ICD-9-CM code 84.12-.19), excluding toe amputations. Those persons with amputations due to trauma, bone malignancy, or congenital anomalies were excluded. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Postacute care service utilization. RESULTS: There were 16,759 discharges with an amputation procedure over this period. The average age was 69.3+/-14.3 years, and 51.9% were men. Black persons comprised 42.4% of the sample. Diabetes was present in 42.0%, and peripheral vascular disease was noted for 66.1% of amputees. Amputations were at the foot (19.4%), transtibial (38.1%), and transfemoral (42.4%) levels. The largest proportion (40.6%) of patients was discharged directly home after acute care, 37.4% went to a nursing home, 9.2% went home with home care, and 9.6% were discharged to an inpatient rehabilitation unit. From 1986 to 1997, there were downward trends in the rate of discharges directly home and corresponding upward trends in nursing home and inpatient rehabilitation dispositions. CONCLUSIONS: Inpatient rehabilitation use is infrequent after dysvascular amputation. Prospective studies are necessary to examine outcomes for persons receiving rehabilitation services in different care settings to define the optimal rehabilitation venue for functional restoration.

Aged↗

Stump length as related to atrophy and strength of the thigh muscles in trans-tibial amputees.

Stump length and the thigh muscles strength of the amputated limb are among the major factors influencing outcome of prosthetic rehabilitation of trans-tibial amputees. In the present study the authors evaluated and compared the strength of quadriceps and hamstrings muscles of both limbs in trans-tibial amputees, as measured by means of an electrical dynamometer. The obtained results showed that the thigh muscles of the sound limbs are significantly stronger than those of the amputated limbs (p < 0.01). The results obtained for amputees with shorter stumps were compared with those with longer stumps. In the group of amputees (n = 9) with a stump shorter than 15.1 cm, values of peak torque (in isokinetic contraction) and maximal average torque (in isometric contraction) were significantly (p < 0.5) weaker when compared to those (n = 9) with a stump longer than 15.1 cm. The results obtained for amputees with a higher rate of thigh muscle atrophy were compared to those with lesser atrophy. In the group of amputees where muscle atrophy was accompanied by decrease in thigh girth of over 5.9 cm, muscles strength did not significantly decrease (p < 0.5) as compared to amputees where thigh girth decrease was less than 5.9 cm. It is concluded that atrophy of the thigh muscles of trans-tibial amputees is accompanied with a significant decrease in strength. In amputees with a short stump, the short lever action provided by the stump interferes with the ability of the thigh muscles to control the prosthesis efficiently during daily activities such as standing and walking.

Activities of Daily Living↗

The effects of prosthesis mass on metabolic cost of ambulation in non-vascular trans-tibial amputees.

The effect of prosthesis mass on the metabolic cost of steady-state walking was studied in ten male non-vascular trans-tibial amputees (TTAs) and ten non-amputee controls. The subjects underwent four trials of treadmill ambulation, with each trial performed for nine minutes at level grade and 76 m/min. Twenty minutes of seated rest followed each trial. During trials numbers one and two, TTAs ambulated without mass added to their prosthesis. During the third and fourth trials, either 454 or 907 grammes mass (1 or 2lbs mass respectively) were randomly assigned and added to either the prosthesis or the leg of the non-amputee control. Subjects were blinded to the amount of mass added to their limb. Within-group comparisons across the four trials showed significant differences in oxygen consumption (VO2) and heart rate (HR) between the two non "mass added" trials, but no effect for addition of mass. The VO2 of TTAs was only 0.6 ml/kg/min (4.7 percent) greater during walking following the addition of 907 grammes to the prosthesis than without mass addition at all, while HR averaged only 1.4 beats/min. higher under the same testing condition. Pearson-product moment correlations echoed these findings, as moderate, but in all cases, negative correlations were observed for associations among the factors of subject age, stump length, and prosthesis-shoe weight, and both VO2 and HR. It was concluded that adding up to 907 grammes mass to a non-vascular TTA's prosthesis will not significantly increase the energy expenditure or HR at a normal walking speed, and that elevated energy cost of ambulation in repeated measures testing without mass added may reflect task familiarization and not an added burden of prosthesis mass.

Adult↗

The influence of the length of lower-limb prosthesis on spinal kinematics.

OBJECTIVE: To examine the immediate effects of a change in prosthetic length on the kinematics of the lumbar spine in lower-limb amputees. DESIGN: An experimental study with repeated measurements of lumbar spine movements under conditions of different prosthetic lengths. SETTING: A free-standing rehabilitation center in the United Kingdom. PARTICIPANTS: Twenty unilateral below-knee amputees. INTERVENTION: Patients performed anatomic movements of the lumbar spine in standing and a sit-to-stand activity. Changes in prosthetic length were produced by placing a wooden block under the prosthetic and sound legs. MAIN OUTCOME MEASURES: The positions of the pelvis and the lumbar spine in standing and the movement patterns of the lumbar spine were recorded by an electromagnetic tracking device. RESULTS: A change in prosthetic length produced lateral tilt of the pelvis and lateral bending of the spine in standing. The mean maximum magnitudes of lateral bending and axial rotation toward the sound and prosthetic sides were different. Subjects exhibited lateral bending and axial rotation when they performed the flexion movement. There were also changes in the direction of coupling between lateral bending and axial rotation in some subjects. CONCLUSION: A change in prosthetic length or leg-length inequality altered the kinematics of the lumbar spine.

Amputation, Surgical↗

Utilization of prostheses among US veterans with traumatic amputation: a pilot survey.

No random surveys have been done to determine how effectively veterans with amputation can utilize their prostheses, and only one limited survey has been done of Scandinavians' use of lower-limb prostheses. A pilot survey of prosthetic problems was sent to all 170 US veteran soldiers who had traumatic amputations over the last 10 years, whose addresses could be supplied by the VA, and whose medical synopses showed them to be otherwise healthy when leaving the military. This subpopulation was selected as a "best case" group: those most likely to be active, young, and healthy enough to use their prostheses, as well as close enough to the military and veterans medical systems to get adequate treatment. If they have problems, the rest of the veterans with amputation, relatively older and more debilitated, are very likely to have far worse problems. Although only 45 responded (26%), all had significant problems using their prostheses for work. Most problems were related to the attachment method. Even if all nonrespondents were problem free, at least a quarter had very significant problems using their prostheses. This means that there are significant problems with current methods for attaching prostheses that need to be addressed. The first step should be a large survey of veterans with amputation to get an accurate assessment of the extent of prosthesis-related problems.

Amputation Stumps↗

Effect of trans-tibial prosthesis pylon flexibility on ground reaction forces during gait.

This study explored the effects of trans-tibial prosthesis pylon flexibility on ground reaction forces (GRFs) associated with walking and step-down. Four (4) active subjects with unilateral trans-tibial amputation and pylon lengths ranging from 4.9 cm to 25.9 cm were studied wearing an aluminium (rigid) pylon and a nylon (more flexible) pylon. Ground reaction forces were collected for the amputated limb during walking at pre-measured self-selected velocity and when stepping down from a 20 cm box. Pylon material significantly affected the magnitudes and patterns of GRFs in both tests. During walking, the most notable differences were seen in the anteroposterior (AP) direction. With the flexible pylon, the AP propulsive peak was greater (p=0.031), and the irregularities in the AP force curve were reduced. Additionally, when walking with the flexible pylon, the vertical peak associated with weight acceptance occurred earlier (p=0.010), the vertical terminal stance peak occurred later (p=0.012), and stance time was longer (p=0.010). During step-down, the vertical loading rate (p=0.010) and the peak vertical force (p=0.010) were greater with the more flexible pylon. Subjective feedback indicated that subjects could distinguish between the two pylons and felt that the nylon component was more comfortable, more flexible, and would enable them to walk more quickly. These results suggest that the pylon may be an influential component of the prosthesis with respect to gait and comfort, and that some degree of flexibility is desirable.

Adult↗