Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ACRYLIC RESINS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91Linked to original sources

Effect of gutta-percha solvents on surface microhardness of IRM fillings.

Eighty identical samples of IRM were prepared and embedded in acrylic resin. The samples were polished, rinsed, and divided into experimental groups and controls, 10 specimens each. Each experimental group was treated for 1 or 5 min with one of the following gutta-percha solvents: chloroform, xylene, or halothane. Sterile saline was used as a control. Treatment consisted of pipetting each solvent onto the external IRM surface. The specimens were then sealed in plastic assay tubes for the corresponding exposure periods. At each time period, surface microhardness of the samples was measured using a mini-load hardness tester with a 500 g load for 20 s. It was found that xylene and halothane caused significant reduction in surface microhardness of IRM after 5 min (p < 0.01). Chloroform caused significant reduction in surface microhardness of IRM after 1 min of treatment (p < 0.01). Chloroform caused total dissolution after 5 min of treatment. Saline caused only minor and nonsignificant changes in surface microhardness of IRM.

Acrylic Resins↗

The effect of occlusal contact localization on the stress distribution in complete maxillary denture.

The fracture of acrylic resin dentures is an unresolved problem in removable prosthodontics despite many efforts to determine its cause. Unfavourable occlusion could be playing an important role in the fracture of the denture. The aim of this study was to investigate the effect of occlusal contact localization on the stress distribution in complete maxillary denture bases utilizing two-dimensional finite element analysis. The results of this study have shown that maximum compressive stresses in a complete maxillary denture under functional masticatory forces concentrates always on the artificial tooth/denture base junction irrespective to the occlusal contact localization. Tensile stresses were observed in areas toward the midline, although the midline itself usually had lower stresses. Shifting the occlusal contacts to a more buccal localization resulted in an increase of the calculated stresses. As a conclusion, it can be speculated that the buccal placement of the occlusal contacts may play a role in the fatigue fracture of the complete maxillary denture.

Acrylic Resins↗

Mycotic growth and soft denture lining materials.

Mycotic flora was studied from the dentures and denture bearing mucosae of 39 persons who wore soft-lined (Molloplast B) mandibular dentures and heat-cured acrylic resin maxillary dentures. Fungal growth was detected in 85% of the mandibular dentures and in 44% of the maxillary dentures (p less than 0.001). On the mandibular mucosa fungal growth was revealed in 74% and on the mucosa of the maxilla in 69%. In connection with inflamed mucosae fungal growth was always detected on the mandibular denture and on the mandibular mucosa in 93% as well as on the maxillary denture in 50% and on the maxillary mucosa in 75%. Considering the healthy mandibular mucosa fungus was found in 75% on the mandibular dentures and in 62% on the mucous membranes. In connection with healthy maxillary mucosae the corresponding figures were 42% and 68%. The specimens revealed 7 different yeasts and 2 moulds. The most common fungi were Candida albicans (86%), Torulopsis glabrata (31%), and C. tropicalis (14%). The uncured Molloplast material caused a definite inhibition of candida growth in vitro, while the cured material indicated no growth inhibition.

Acrylic Resins↗

Evaluation of vertical accuracy of interocclusal records.

PURPOSE: The aim of this study was to evaluate four recording materials (polyether, polyvinyl siloxane, acrylic resin, and wax) for their ability to accurately record, maintain, and reproduce the vertical interocclusal relationship. MATERIALS AND METHODS: A metallic apparatus was used to represent the opposing arches; its epoxy resin duplicate represented the working casts. The vertical discrepancies produced because of the presence of the records were measured both after repositioning them on the metal apparatus and after transferring them onto the casts. Two-way ANOVA was performed. RESULTS: Closure through the interocclusal recording materials produced small vertical discrepancies ranging from 24 to 74 microm. When repositioned on the apparatus, the vertical discrepancies were greater. The lowest discrepancy was displayed by polyvinyl siloxane (101 microm) and polyether (107 microm), and the greatest was displayed by wax (168 microm). When records were transferred onto casts, the discrepancies were approximately 0.5 mm, without significant differences among materials. CONCLUSION: Closure through interocclusal recording materials and removal and repositioning of the records on the apparatus produced small vertical discrepancies with clinically insignificant differences between the materials tested. When records of all materials tested were transferred onto casts, vertical discrepancies of approximately 0.5 mm were found, which is of clinical concern.

Acrylic Resins↗

Relationship of film properties to drug release from monolithic films containing adjuvants.

The rate of drug release from a polymeric matrix system was influenced by the physical and chemical properties of the monolithic films. The model drugs, salicylic acid and chlorpheniramine maleate, and two poly(methyl methacrylate) copolymers of different permeabilities (Eudragit RL and Eudragit RS), with and without additional adjuvants, were used to form monolithic matrix films for controlled drug release. Adjuvants, including polyethylene glycols (PEG 400 and PEG 8000) and poly(vinylpyrrolidones) (PVP-K15 and PVP-K90), were incorporated into films of Eudragit RL PM and Eudragit RS PM. The moisture permeation constant, glass transition temperature (Tg), tensile strength, and drug release profiles were determined for each acrylic resin slab to correlate the physicochemical and physicomechanical film properties to observed drug release. Faster rates of drug diffusion were observed with the addition of PEG 400 to the films, because of its plasticizing effect and the resultant increased moisture permeability of the matrix. An exception existed with the Eudragit RL PM film containing salicylic acid where drug-polymer interactions inhibited drug diffusion. The small changes in moisture permeability, Tg, and tensile strength observed with incorporation of the PVPs had an insignificant influence on the dissolution results for salicylic acid from Eudragit RS PM films. Increases in the tensile strength and Tg after addition of PVP to the Eudragit RS PM matrix support the observed decreased rate of diffusion for chlorpheniramine maleate. The pores formed by migration of the hydrophilic adjuvants from the films altered the diffusion kinetics of the matrix, compared with that of the nonporous polymer, when only the antihistamine was present.

Acrylic Resins↗

Immediate occlusal loading of Osseotite implants in the completely edentulous mandible.

PURPOSE: This article reports the preliminary data from a clinical study of immediately loaded, full-arch, screw-retained prosthesis with distal extensions (hybrid prosthesis) supported by Osseotite implants placed in the edentulous mandible. MATERIALS AND METHODS: Fifteen patients who received 103 implants were enrolled in this study. The first 2 patients received both immediately loaded and submerged implants, while the remaining patients had all implants immediately loaded. The first 9 patients received a temporary prosthesis within 4 hours of surgery, and the hybrid prosthesis, made of a titanium framework and acrylic resin teeth, was placed after 6 months. The last 6 patients received the same type of hybrid prosthesis within 36 hours of surgery. Marginal bone loss was monitored via periapical radiographs by a computerized technique. RESULTS: One failure (out of the 92 immediately loaded implants) occurred after 3 weeks of function because of infection. A cumulative success rate of 98.9% was achieved for up to 48 months of follow-up, while the prosthetic cumulative success rate for the same period was 100%. Marginal bone loss at the immediately loaded implants was within the generally accepted conventional limits for standard delayed loading protocols. DISCUSSION: This technique can reduce treatment time but should be applied with caution. CONCLUSION: The preliminary results of this study suggest that rehabilitation of the edentulous mandible by an immediately loaded hybrid prosthesis supported by 5 to 6 implants may represent a viable alternative treatment to the classical delayed loading protocols.

Acrylic Resins↗

Viscoelastic and adherence properties of dental relining materials.

The viscoelastic properties of three classes of soft relining materials (acrylic resins, silicones, and EVA copolymers) were studied comparatively. Their behaviors were investigated by in vitro tests at a frequency omega = 1 Hz, which stimulates the masticatory cycle. The experimental parameter was the temperature (T). Black graphs giving the variations of the stiffness K--proportional to the complex viscoelastic modulus Ex(T) omega--according to the phase angle delta, were used for a predictive approach to increase the comfort of removable dentures. Cole-Cole diagrams, describing the variation of the loss modulus E"(T) omega in relation to the storage modulus E'(T)omega additionally provide quantitative data. The values obtained were related to the noninteger parameter h used for modelization of the viscoelastic behavior of the materials by means of nonlinear Zener models. An attempt was made to correlate the experimental data to the viscoelastic energy loss observed when instability of the prosthetic structure occurs. This attempt takes into account the formation of "cracks" (areas of inadaptation) between the prosthetic intrados and the mucosa.

Acrylic Resins↗

Randomized controlled clinical trial for verifying the effect of silicone-based resilient denture liner on the masticatory function of complete denture wearers.

PURPOSE: The purpose of this study was to investigate whether application of permanent silicone-based resilient denture liner (SR) to mandibular complete dentures significantly improves patients' masticatory ability compared to conventional heat-activated acrylic resin (AR). MATERIALS AND METHODS: Twenty-eight edentulous patients were randomly placed into 1 of 2 crossover groups (AR-SR/SR-AR) by using a random permuted block within strata method. The AR-SR group received AR denture treatments followed by SR denture treatments. The SR-AR group received treatments in the reverse sequence. The outcomes were classified by matiscatory performance, mandibular movement, electromyographic activity, and maximum occlusal force. RESULTS: No significant differences were observed in any of the baseline characteristic measurements between groups. SR denture wearers exhibited significantly higher masticatory performance than AR denture wearers. SR denture wearers exhibited a longer early-stage occluding period than AR denture wearers. There were no differences in electromyographic activity between the AR and SR groups. There were no significant differences in maximum occlusal force between the AR and SR groups. CONCLUSION: This study showed that the application of SR to mandibular complete dentures resulted in significant improvements to the patients' masticatory ability compared to AR.

Acrylic Resins↗

Effects of sandblasting and electrical discharge machining on porcelain adherence to cast and machined commercially pure titanium.

The aim of this study was to determine the effect of sandblasting and electrical discharge machining (EDM) on cast and machined titanium surfaces and titanium-porcelain adhesion. Twenty machined titanium specimens were prepared by manufacturer (groups 1 and 2). Thirty specimens were prepared with autopolymerizing acrylic resin. Twenty of these specimens (groups 3 and 4) were cast with commercially pure titanium and the alpha-case layer was removed. For control group (group 5), 10 specimens were cast by using NiCr alloy. Groups 2 and 4 were subjected to EDM while groups 1, 3, and 5 were subjected to sandblasting. Surface examinations were made by using a scanning electron microscope (SEM). A low-fusing porcelain was fused on the titanium surfaces, whereas NiCr specimens were covered using a conventional porcelain. Titanium-porcelain adhesion was characterized by a 3-point bending test. Results were analyzed by Kruskal-Wallis and Mann-Whitney U tests. Metal-porcelain interfaces were characterized by SEM. The bond strength of control group was higher than that of the titanium-porcelain system. There was no significant difference between cast and machined titanium groups (p > 0.05). There was no significant difference between EDM and sandblasting processes (p > 0.05). The use of EDM as surface treatment did not improve titanium-porcelain adhesion compared with sandblasting.

Acrylic Resins↗

Denture plaque and adherence of Candida albicans to denture-base materials in vivo and in vitro.

The aim of this paper is to review our understanding of the mechanisms and clinical significance of adhesion of C. albicans to denture-base materials in relation to denture plaque and denture-related stomatitis. Earlier reports in the literature of a 65% prevalence level of denture-related stomatitis seem to be exaggerated. More recent studies indicate that denture-related stomatitis is considerably less common, particularly in normal healthy subjects. The etiology of the condition is discussed in this review, and although much of the literature supports the view that the condition is strongly associated with C. albicans, this is not always so. In some subjects, the cause appears to be related to a non-specific plaque. This review also considers the role of denture plaque in the pathogenesis of denture-related stomatitis, the sequential development of denture plaque, and its colonization by Candida organisms. Designing controlled in vivo studies is difficult, and as a consequence, many investigators have had to resort to in vitro studies. The majority of these studies have attempted to investigate the hydrophobicity of C. albicans, relating the surface free-energy of denture-base materials, particularly acrylic resin, to that of the organism. Surprisingly little work has been directed at surface roughness and how it affects retention of organisms. Further, no attention has been paid to the properties and character of the surface, other than average surface roughness, as it affects adhesion. A comparison of results from in vitro studies on the effect on adhesion of pre-coating the surfaces of denture-base materials with saliva has produced equivocal conclusions. This is largely due to little standardization of experimental protocols between studies, particularly in the collection and handling of the saliva used. In conclusion, the review strongly supports the suggestion that adherence of C. albicans to denture-base materials in vitro is related to the hydrophobicity of the organism. The clinical significance of the observation and the mechanisms for the development and maturation of denture plaque are yet to be understood. There is a clear need for further investigation of other factors that may moderate the adhesion of organisms and subsequent colonization of denture-base materials.

Acrylic Resins↗

Posterior unilateral condylar displacement: its diagnosis and treatment.

The treatment procedure for posterior unilateral condylar displacement has been described. An acrylic resin repositioning prosthesis may be used to decrease trismus. Occlusal adjustment permits lateral freedom for mandibular movement to the opposite side which provides a dual, or a therapeutic, centric occlusion as well as the existing dysfunctional centric relation. This permits the patient's physiologic adaptive mechanism to choose between the existing dysfunctional centric relation, which resulted in unilateral condylar retrusion and pain, or a therapeutic centric occlusion which is aimed at anterior unilateral condylar repositioning. Over long period of time, muscle reprogramming produces maximum intercuspation of teeth in the planned therapeutic centric occlusion rather than in the original dysfunctional position. No explanation has been established for this phenomenon. It is important, however, to provide a technique that permits physiologic adaptability over a period of time. It should be emphasized that this is not TMJ "remodeling" but a functional change in the position of the jaw. The treatment objectives of bilateral and unilateral posterior condylar displacement are similar, but the clinical techniques are completely different. In either instance, TMJ radiographs are necessary to establish the diagnosis and treatment, as well as to document the postoperative results.

Acrylic Resins↗

The effect of partial denture connectors on gingival health.

The effect on the gingiva of a variety of relationships of a removable partial denture connector to the gingival margin was investigated in 10 subjects. Acrylic resin baseplates were designed incorporating a variety of relationships of the connector to the gingival margin. The appliances were worn for a 12 hour period daily, for 21 days. At baseline and at days 7, 21 and 49, plaque index, gingival index and probing pocket depth measurements were recorded, and subgingival plaque samples were examined using darkfield microscopy. No increase in plaque accumulation was detected in any area at any time interval. There was a significant increase in gingival index at day 21 in areas where the appliance covered the gingival margin. Small increases in probing pocket depth were recorded at day 21, there being no difference between any of the test areas. Baseline values were re-established by day 49. No significant differences were detected in the percentage of motile organisms or spirochaetes counted in the subgingival plaque samples collected from any area. It was concluded that deterioration in gingival health occurred rapidly following the insertion of a removable appliance, and that coverage of the gingival margin, irrespective of the degree of gingival relief, had a detrimental effect.

Acrylic Resins↗

Immunoelectron microscopic localization of chlamydial lipopolysaccharide (LPS) in McCoy cells inoculated with Chlamydia trachomatis.

Interactions between Chlamydia trachomatis, host cells, and the immune system are believed to involve lipopolysaccharide (LPS). We used immunogold techniques to study the distribution of chlamydial LPS in cultured cells infected with C. trachomatis LGV-L1. McCoy cells inoculated with C. trachomatis were cultured and then fixed and embedded in situ with acrylic resins. Sections were immunolabeled with a protein A-gold method using antisera to the genus-specific, periodate-sensitive epitope on chlamydial LPS. Pre-embedding immunogold labeling on permeabilized cells was also done. By post-embedding methods, labeling for LPS was equally abundant over the outer membranes of elementary (EB) and reticulate bodies (RB). By post-embedding labeling, the sub-surface side of the EB outer membrane was more heavily labeled than the surface side. By pre-embedding labeling, LPS was found to be less abundant on the surface of EBs than RBs. Labeling for LPS was found over apparent lysosomes in McCoy cells and over electron-dense blebs on or near the surface of the plasma membranes of McCoy cells. These results indicate that the concentration of LPS in chlamydial membranes is constant during development but that with development its location changes from being mostly cell-surface to sub-surface. These results show that the post-embedding immunogold technique can be a useful approach for the cell culture-based study of chlamydial LPS.

Acrylic Resins↗

Use of microwave energy to disinfect a long-term soft lining material contaminated with Candida albicans or Staphylococcus aureus.

STATEMENT OF PROBLEM: Soft lining materials have been found to be more susceptible to microbial adhesion than acrylic resin base materials. Denture hygiene is essential to maintain the serviceability of the denture, and microwave energy has been suggested for denture disinfection. PURPOSE: The purpose of this study was to determine the effectiveness of microwave energy in the disinfection of a long-term soft lining material. MATERIAL AND METHODS: A long-term soft lining material was contaminated with known microorganisms and the reduction of organism counts after test disinfection regimes calculated. The disinfection regimes were microwaving for 5 minutes, leaving dry overnight, and soaking overnight in a dilute sodium hypochlorite solution. The test microorganisms were Candida albicans or Staphylococcus aureus. RESULTS: For both organisms, soaking in sodium hypochlorite reduced the number of viable adherent microorganisms recovered significantly more than exposure to microwave energy, which led to greater reduction than leaving the lining material dry overnight (p < 0.001, Wilcoxon nonparametric signed rank test). CONCLUSION: With reference to the tested microorganisms, disinfection of Molloplast-b soft lining material in dilute sodium hypochlorite solution proved to be more effective than exposure to microwave energy, which in turn was more effective than leaving the lining dry overnight.

Acrylic Resins↗

An Eudragit-coated prednisolone preparation for ulcerative colitis: pharmacokinetics and preliminary therapeutic use.

Prednisolone metasulphabenzoate, a steroid with poor colonic absorption, was coated with the pH-dependent acrylic resin Eudragit S, as a means of delivering an orally administered preparation to the proximal colon. The therapeutic potential of delivering this steroid with potentially less systemic side-effects to the proximal colon was assessed in extensive ulcerative colitis. Plasma and urine prednisolone profiles in 6 healthy volunteers confirmed minimal absorption from Eudragit S-coated prednisolone metasulphabenzoate compared to prednisolone acetate: peak plasma prednisolone concentrations 29 +/- 21 ng/ml vs. 570 +/- 185 ng/ml (P less than 0.01), area under curve measurements 204 +/- 214 vs. 2724 +/- 1236 ng.h/ml (P less than 0.01). Prednisolone metasulphabenzoate coated with Eudragit S (30-60 mg daily) was then administered for 12 weeks to 12 patients with colonoscopically proven extensive ulcerative colitis in relapse. Symptoms, sigmoidoscopic appearances and rectal histological abnormalities all improved during therapy. Complete clinical remission occurred in 7 patients, a partial response in 2 patients and no response in 3 patients. Cortisol responses to tetracosactrin demonstrated no significant adrenal suppression following treatment. Eudragit S-coated prednisolone metasulphabenzoate may be a useful treatment for extensive ulcerative colitis, without risk of systemic steroid side-effects.

Acrylic Resins↗

Effect of adhesives on bond strength of porcelain veneer to base metal alloy.

OBJECTIVE: The purpose of this in vitro study was to evaluate the bond strength of porcelain veneer to base metal alloy using different adhesive systems. METHOD AND MATERIALS: Eighty cylindrical models were cast in a nickel-chromium-beryllium base metal alloy. After they were mounted in self-cured acrylic resin, the surfaces of the specimens were air abraded. Specimens were divided into four groups of 20. Control porcelain disks were baked on the base metal. For the experimental groups, 60 porcelain disks were made. After 50-microm aluminum oxide sandblasting, a silane coupling agent was applied to the surface of the porcelain. The experimental groups were based on the type of adhesive used to bond porcelain to metal: Scotchbond Multipurpose and Duo Cement; One Coat Bond and Duo Cement; or Panavia 21 Ex. After 500 thermal cycles, the bonded porcelain specimens were placed under a continuous shear load of 2 mm/min until fracture occurred. RESULTS: Mean values for bond strength were 25.39 (control), 19.10 (Panavia 21 Ex), 15.81 (Scotchbond Multipurpose), and 13.69 MPa (One Coat Bond). Statistically significant differences in bond strength were noted between the control group and all the experimental groups. A statistically significant difference was observed between Panavia 21 Ex specimens and One Coat Bond specimens. CONCLUSION: Panavia 21 Ex provided an effective bond strength between a porcelain veneer and a base metal alloy, the closest of all the experimental groups to that of the control group.

Acrylic Resins↗

The use of computed tomography in the detection of radiolucent denture base material in the chest.

With the introduction of acrylic resin denture base materials to the dental profession, radiolucency was recognized as a significant deficiency at an early stage. Continuous research into the production of a radiopaque material has been directed at including radiopaque glasses, salts or metals powders in an otherwise radiolucent polymer. However, the majority of new dentures are still made in radiolucent material which is notoriously difficult to locate by conventional radiography and reports continue to appear relating to the inhalation or ingestion of dentures (or fragments of them), occasionally leading to the death of the patient. Advances in radiographic techniques and equipment have seen the development of computed tomography (CT). This has proved invaluable as a diagnostic aid for disease and therapy but little attention appears to have been given to the use of this sophisticated technique in the detection of foreign bodies, in particular those of dental origin. This study investigates the use of CT in the detection of radiolucent denture base material. The results suggest that CT has substantial advantages over conventional radiography in the detection of this material and should be considered as a valuable diagnostic aid in those patients thought to have inhaled dentures or fragments of dentures.

Acrylic Resins↗

[The effect of rehabilitation of flared root canal on the fracture resistance of root and post-core system].

OBJECTIVE: To assess the effect of rehabilitation of flared root canal on the fracture resistance of root and post-core system. METHODS: Thirty-two simulated tooth roots made of polymethyl methacrylate were divided into 4 groups, including the normal root canal group and 3 flared root canal groups. One flared root canal group was rehabilitated by light-cared composite, another group was rehabilitated by amalgam, and the third flared root conal group was not treated. Casting post and core restored every simulated tooth root. Each specimen was embedded in acrylic resin and then fixed in a special jig on the universal load-testing machine. A compressive load was applied at a 90-degree angle to the long axis of the core until fracture, at a crosshead speed of 1 mm/min; the maximum of load was recorded. RESULTS: The means of load in normal root canal group, light-cared composite rehabilitated group, amalgam rehabilitated group, not treated group were 202.92 N, 194.60 N, 146.89 N, 142.09 N. It was shown that the load of normal root canal group is significantly greater than the load of not-treated group (P < 0.01); the light-cared composite rehabilitated group is significantly stronger than the not-treated group (P < 0.01), but there is no significant difference between the light-cared composite rehabilitated group and normal root canal group, and no significant difference between the amalgam rehabilitated group and not-treated group (P > 0.05). CONCLUSION: The rehabilitation of flared root canal using suitable material not only changes the shape of root canal, but also increases the fracture resistance of root canal because of its thicker and stronger root canal wall which obviously improves the fracture resistance of post and core.

Acrylic Resins↗