Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Torque”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90Linked to original sources

The effects of cyclic loading on pull-out strength of sacral screw fixation: an in vitro biomechanical study.

STUDY DESIGN: The pull-out strength of sacral screw fixation after cyclic loading was tested using young human cadaveric specimens. OBJECTIVES: To evaluate the effects of fatigue loading on the pull-out strength of medial and lateral unicortical and bicortical sacral screws and to correlate the pull-out strength with sacral bone density and the screw insertion torque. SUMMARY OF BACKGROUND DATA: The immediate biomechanical effects of depth of penetration, screw orientation, and bone density on sacral screw fixation have been studied in aged cadaveric specimens. The effect of cyclic loading on the pull-out strength of sacral screw fixation is unknown, however, and data from young specimens is rare. METHODS: Eleven fresh specimens of human sacrum were used in this study. Bone mineral density at the vertebral body and the ala were determined by peripheral quantitative computed tomography. Seven-millimeter compact Cotrel-Dubousset sacral screws were inserted into the sacrum anteromedially and anterolaterally, both unicortically and bicortically, and the insertion torque for each screw was measured. Cyclic loading from 40 to 400 N was applied to each screw at a frequency of 2 Hz up to 20,000 cycles. Pull-out tests were conducted after completion of the fatigue tests. RESULTS: The average bone density was 0.38 +/- 0.08 g/mL at the S1 body and 0.24 +/- 0.05 g/mL at the S1 ala. The insertion torque and average pull-out force after cyclic loading were significantly higher for bicortical fixation than for unicortical fixation for a particular screw alignment. The pull-out strength and insertion torque of medially oriented fixation was always higher than that for lateral fixation, however, regardless of whether the insertion was unicortical or bicortical. The pull-out force of unicortical and bicortical medial screw fixations after cyclic loading showed significant linear correlations with both the insertion torque and the bone mineral density of the S1 body. CONCLUSIONS: In a young population, screw orientation (anterolateral or anteromedial) was more important in determining pull-out strength than screw depth (unicortical or bicortical) after fatigue loading, anteromedially directed screws being significantly stronger than laterallyplaced screws. Bone mineral density of the S1 body andinsertion torque were good preoperative and intraoperative indicators of screw pull-out strength.

Adult↗

Posture-dependent isometric trunk extension and flexion strength in normal male and female subjects.

The objective of this study was to quantify the relationship between trunk posture and trunk muscle function in a group of young, normal male and female subjects. Ten male and 10 female subjects performed isometric flexion and extension tasks using a trunk dynamometer. Peak isometric torque was recorded in flexion and extension at 10 degrees increments over a sagittal posture range of -20 degrees extension to +50 degrees of flexion. Significant differences in trunk strength (isometric torque) were found between males and females, at various sagittal plane trunk postures, and between flexion (F) and extension (E) tasks. Flexion torque was greatest at 20 degrees to 30 degrees flexion, whereas extension torque was greatest at 50 degrees flexion. Gender-specific differences in trunk strength were markedly reduced when the torque data were normalized by the subject's height multiplied by body weight. The E/F torque ratio showed a relatively linear, over twofold increase with increasing flexion angle, and was significantly greater for female subjects compared with male subjects at most sagittal postures. The baseline trunk isometric strength data provided by this study should help clinicians to use strength testing more precisely and specifically in prevention and diagnosis of patients at risk for back disorders.

Adult↗

A stronger bicortical sacral pedicle screw fixation through the s1 endplate: an in vitro cyclic loading and pull-out force evaluation.

STUDY DESIGN: The insertion torque and pull-out force after cyclic loading of the bicortical sacral pedicle screw through the S1 endplate were tested using human cadaveric specimens. OBJECTIVES: The purpose of this study was to (1) evaluate the effect of cyclic loading on the pull-out force of two different techniques of bicortical sacral pedicle screw fixation and (2) to correlate the pull-out force after cyclic loading with the screw insertion torque. SUMMARY OF BACKGROUND DATA: Biomechanical studies using conventional sacral pedicle screw fixation techniques have demonstrated reduction in stiffness and strength after cyclic loading. Technical difficulties with anterior sacral cortex penetration and frequent screw loosening have been reported in clinical studies. In the authors' center, a new method of sacral pedicle screw fixation bicortically through the S1 endplate has been used successfully in the clinical setting. However, the mechanical stability of this new technique after undergoing cyclic loading has not been documented in the literature. METHODS: Seven-millimeter compact Cotrel-Dubousset sacral screws were randomly assigned by side (left vs. right) and inserted bicortically either anteromedially through the anterior sacral cortex or superiorly through the S1 endplate of 17 fresh frozen human sacrum. The tk;4maximum insertion torque for each screw was measured. Cyclic loading from 40 N to 400 N was applied to each screw at a frequency of 2 Hz for 20,000 cycles. Pull-out tests were conducted after completion of the cyclic tests. RESULTS: The mean maximum insertion torque and mean pull-out force following cyclic loading were significantly higher for bicortical fixation through the S1 endplate (mean 3.17 N.m and 1457 N) than bicortical fixation through the anterior sacral cortex (mean 1.98 N.m and 1122 N). Both S1 endplate and anterior cortical fixation techniques demonstrated significant correlations between insertion torque and pull-out force following cyclic loading. CONCLUSIONS: In sacral pedicle screw fixation, screw trajectory through the S1 endplate was significantly stronger than screws penetrating the anterior sacral cortex. Insertion torque was a good intraoperative indicator of screw pull-out force after cyclic loading.

Adult↗

Screw loosening for standard and wide diameter implants in partially edentulous cases: 3- to 7-year longitudinal data.

Screw loosening is considered to be a common problem with both screw-retained and cemented implant restorations. A wider abutment platform, as well as using a torque driver to tighten specifically designed screws may help prevent this loosening. However, there has been no clinical study evaluating either of these. To longitudinally compare the frequency of screw loosening in standard diameter, (3.75 and 4.0 mm) implant supported prostheses to that of wide diameter, (5.0 and 6.0 mm) implant supported prostheses that were hand tightened, and to evaluate whether using a torque driver would minimize or prevent this problem, if screw loosening occurred. A total of 213 dental implants in 106 patients were included in this prospective longitudinal study. Of the implants 68 were wide diameter and 145 were standard diameter implants. Wide diameter implants showed 5.8% screw loosening, while standard diameter implants showed 14.5% screw loosening after insertion with only hand torquing. When these loose screws were tightened with a torque driver, there was no more loosening of screws. Within the limitations of this study, the wide diameter implants tested showed less screw loosening than the standard diameter implants when hand torqued. Additionally, within the scope of our study, using a torque driver to tighten the screws with the recommended force prevented this loosening from reoccurring in all cases.

Adult↗

Increased risk for falling associated with obesity: mathematical modeling of postural control.

Recent epidemiological studies report that obesity is positively related to fracture incidence. In the present experiment, a model of postural control was used to examine the impact of an abnormal distribution of body fat in the abdominal area upon postural stability. Obese and lightweight humanoids were destabilized by imposing a small initial angular speed from a neutral standing position. To avoid a loss of stability yielding a stepping reaction or a fall, an ankle torque is necessary to counteract the perturbation. Three torque parameters--ankle torque onset, time to peak torque, and muscular ankle torque--were entered in a program to simulate the intrinsic variability of the human postural control system. A loss of stability was detected when the center of pressure exceeded stability margins. The most striking observation is the nonlinear increase of torque needed to stabilize the humanoid when the motor response was characterized by delayed temporal parameters. The effect was more pronounced when an anterior position of the center of mass was included in the simulations. This suggests that, when submitted to daily postural stresses and perturbations, obese persons (particularly those with an abnormal distribution of body fat in the abdominal area) may be at higher risk of falling than lightweight individuals.

Abdomen↗

The effect of joint angle on the timing of muscle contractions elicited by neuromuscular electrical stimulation.

Neuromuscular electrical stimulation was used to evoke isometric knee extension contractions in seven individuals with spinal cord injury (SCI) and the time for knee extension torque to rise and fall was measured across a range of knee angles. The stimulated muscles took more than twice as long to develop 50% of maximum torque at an angle of 15 degrees, compared to an angle of 90 degrees. This time difference comprised both an increased delay before torque rose above resting levels (31 +/- 3 ms at 90 degrees, 67 +/- 24 ms at 15 degrees), and a prolonged duration over which torque was rising (72 +/- 14 ms at 90 degrees, 140 +/- 62 ms at 15 degrees). There was no change, however, in the time taken for torque to fall after cessation of stimulation at different knee angles (58 +/- 5-ms delay, 60 +/- 11-ms fall time). The difference in torque rise time with joint angle has implications for modeling functional activities that differ greatly in their joint angles. This study provides regression equations whereby activation times for the quadriceps muscles of individuals with SCI can be predicted for specific angles of knee flexion.

Adult↗

Behaviour of Hero NiTi instruments used by an experienced operator under access limitations.

The purpose of this study was to evaluate the failure incidence of Hero 642 nickel-titanium (NiTi) rotary instruments (HRI) when used by an experienced operator in conjunction with different motors and under limitations of access. HRI were used by an experienced operator in a crown-down technique. The teeth were mounted in resin arches of a phantom head to reproduce limitations of access. In Groups 1, 2, 3 and 4, air, high torque control, low torque control and very low torque control motors were used respectively. Each group included 30 canals in extracted human molars. One set of HRI was used for each canal; the HRI were sterilised before each case. A 2.5% NaOCl solution was used as an irrigant. An experienced operator performed all the cleaning and shaping procedures after application of a rubber dam. The opening of the mouth in the phantom head was standardised for the four groups. Instrument fracture did not occur in any of the groups. The air, high torque control and low torque control motors were as safe as the very low torque control motor when HRI were used by an experienced operator in a crown-down manner at 300 rpm.

Air↗

Quantitative analysis of the velocity related pathophysiology of spasticity and rigidity in the elbow flexors.

OBJECTIVE: To quantify velocity dependent and position related properties of increased muscle tone measured during a constant velocity stretch. METHODS: Elbow flexors were vertically stretched under four different velocities (40, 80, 120, and 160 degrees /s) through a 75 degrees range of motion in 12 patients with hemiparesis, 16 with parkinsonism, and 12 normal controls. From reactive torque measurement, a linear second order model was adopted to dissociate velocity dependent viscous and velocity independent elastic components. The averaged speed dependent reflex torque (ASRT)--defined as the deviation of measured torque from baseline torque--was used to quantify the viscous component of hypertonia. Velocity sensitivity of ASRT (VASRT) and segmented ASRT (SASRT), derived from the slope of the regression line among ASRT velocity plots and from segmentations of reactive torque, respectively, were used to differentiate the increased muscle tone of spasticity and rigidity. RESULTS: ASRT and VASRT were significantly higher in both spasticity and rigidity than in normal controls. SASRT analysis showed three different position related patterns among spasticity, rigidity, and normal groups: spasticity showed progressively increasing muscle tension relative to position; rigidity showed increased (relative to the norm) but constant muscle tone over the entire stretch range; the normal control group showed a consistently low reactive torque over the entire range. CONCLUSIONS: Velocity dependence analysis indicates that rigidity and spasticity have approximately equal velocity dependent properties. For differentiating these two types of hypertonia, position dependent properties my be employed.

Adult↗

Bone mineral density measurement with dental quantitative CT prior to dental implant placement in cadaver mandibles: pilot study.

PURPOSE: To correlate torque forces during insertion of screw-type dental implants with bone mineral density (BMD) values determined preoperatively. MATERIALS AND METHODS: Dental quantitative computed tomography (CT) was performed with simultaneous imaging of five postmortem mandibles and a calibration standard containing defined concentrations of calcium hydroxyapatite. CT numbers were converted to local BMD values by assuming a linear relationship (BMD = a x HU + b), where a and b are calibration coefficients. The a, b, P, and t values, correlation coefficients, and standard errors were calculated. Dental implants (n = 25) were set, and insertion torques were recorded. BMD was determined at the implantation site and correlated with torque forces recorded during implant insertion. Calibration coefficients derived for specimens were compared with those derived for actual patients. RESULTS: Calibration coefficients (at 120 kV) for the postmortem specimens were a = 0.760 +/- 0.03 (mean +/- SD) and b = 2.8 +/- 3.7 and for the patients were a = 0.804 +/- 0.06 and b = 5.2 +/- 4.2. Calibrated BMD values at the location of dental implants exhibit a significant correlation (R(2) = 0.83, P <.001) with insertion torques on the basis of a second-order model, which yields torque = (0.0055 x BMD + 0.73)(2) for the implants used and the surgical technique applied. CONCLUSION: Correlation exists between BMD measured with dental quantitative CT and the insertion torque of dental implants.

Bone Density↗

Influence of aging on sex differences in muscle fatigability.

The purpose of this study was to compare time to task failure for a sustained isometric contraction performed at a submaximal intensity with elbow flexor muscles by young and old men and women. Twenty-seven young (14 men and 13 women, 18-35 yr) and 18 old (10 men and 8 women, 65-80 yr) adults sustained an isometric contraction at 20% of maximal voluntary contraction torque until target torque could no longer be achieved for > or = 5 s. Young adults were stronger than old adults (66.8 +/- 17.9 vs. 47.7 +/- 18.1 N x m, P < 0.05), and men were stronger than women (69.8 +/- 17.9 vs. 47.1 +/- 15.3 N x m, P < 0.05), with no interaction between age and sex (P > 0.05). Time to task failure was longer for old than for young adults (22.8 +/- 9.1 vs. 14.4 +/- 7.6 min, P < 0.05) and for young women than for young men (18.3 +/- 8.0 vs. 10.8 +/- 5.2, P < 0.05), but there was no difference between old women and men (21.3 +/- 10.7 and 24.1 +/- 8.0 min, respectively, P > 0.05) or between young women and old adults (P > 0.05). Mean arterial pressure, heart rate, average electromyographic (EMG) activity, and torque fluctuations of elbow flexor muscles increased during the fatiguing contraction (P < 0.05) for all subjects. Rates of increase in mean arterial pressure, heart rate, and torque fluctuations were greater for young men and old adults, with no differences between old men and women (P > 0.05). Similarly, the rate of increase in EMG activity was greater for young men than for the other three groups. EMG bursts were less frequent for old adults (P < 0.05) at the end of the fatiguing contraction, and this was accompanied by reduced fluctuations in torque. Consequently, time to task failure was related to target torque for young, but not old, adults, and differences in task duration were accompanied by parallel changes in the pressor response.

Adult↗

Effect of altering starting length and activation timing of muscle on fiber strain and muscle damage.

Muscle strain injuries are some of the most frequent injuries in sports and command a great deal of attention in an effort to understand their etiology. These injuries may be the culmination of a series of subcellular events accumulated through repetitive lengthening (eccentric) contractions during exercise, and they may be influenced by a variety of variables including fiber strain magnitude, peak joint torque, and starting muscle length. To assess the influence of these variables on muscle injury magnitude in vivo, we measured fiber dynamics and joint torque production during repeated stretch-shortening cycles in the rabbit tibialis anterior muscle, at short and long muscle lengths, while varying the timing of activation before muscle stretch. We found that a muscle subjected to repeated stretch-shortening cycles of constant muscle-tendon unit excursion exhibits significantly different joint torque and fiber strains when the timing of activation or starting muscle length is changed. In particular, measures of fiber strain and muscle injury were significantly increased by altering activation timing and increasing the starting length of the muscle. However, we observed differential effects on peak joint torque during the cyclic stretch-shortening exercise, as increasing the starting length of the muscle did not increase torque production. We conclude that altering activation timing and muscle length before stretch may influence muscle injury by significantly increasing fiber strain magnitude and that fiber dynamics is a more important variable than muscle-tendon unit dynamics and torque production in influencing the magnitude of muscle injury.

Animals↗

Neuromuscular fatigue development during maximal concentric and isometric knee extensions.

This study aimed to investigate mechanisms of neuromuscular fatigue during maximal concentric and isometric leg extensions inducing similar torque decrements. Nine physically active men performed two separate fatiguing sessions maintained until similar torque decreases were obtained. The first session, only conducted under isokinetic concentric conditions (CON), consisted of three series of 30 maximal voluntary concentric knee extensions (60 degrees/s). The second session, exclusively isometric (ISO), mimicked the torque decreases registered during the CON session while performing three long-lasting ISO contractions. Maximal voluntary torque, activation level (twitch interpolation technique), electromyographic activity (root mean square and median frequency) of the vastus lateralis muscle, and electrically evoked doublet-twitch mechanical properties were measured before and at the end of each of the three series. After the three series, similar torque decrements were obtained for both fatiguing procedures. The total fatiguing contraction durations were not different among procedures. With equivalent voluntary torque decrements, the doublet-twitch amplitude reduction was significantly greater (P<0.01) during the two first series of the CON procedure compared with ISO. No difference was observed for the third series. Although no difference was recorded with fatigue for median frequency changes between CON and ISO, activation levels and root mean square values demonstrated greater reductions (P<0.05) for all three series during the ISO procedure compared with CON. Performing CON or ISO fatiguing exercises demonstrated different fatigue origins. With CON exercises, peripheral fatigue developed first, followed by central fatigue, whereas with ISO exercises the fatigue pattern was inverted.

Adult↗

Muscle activity determined by cosine tuning with a nontrivial preferred direction during isometric force exertion by lower limb.

We investigated how the CNS selects a unique muscle activation pattern under a redundant situation resulting from the existence of bi-articular muscles. Surface electromyographic (EMG) activity was recorded from eight lower limb muscles while 11 subjects were exerting isometric knee and hip joint torque simultaneously (T(k) and T(h), respectively. Extension torque was defined as positive). The knee joint was kept at either 90 or 60 degrees. Various combinations of torque were imposed on both joints by pulling a cable attached to an ankle brace with approximately three levels of isometric force in 16 directions. The distribution of the data in the three-dimensional plot (muscle activation level quantified by the root mean squared value of EMG vs. T(k) and T(h)) demonstrates that the muscle activation level M can be approximated by a single model as M = left flooraT(k) + bT(h) right floor where left floorx right floor = max (x,0) and a and b are constants. The percentage of variance explained by this model averaged over all muscles was 82.3 +/- 14.0% (mean +/- SD), indicating that the degree of fit of the data to the plane was high. This model suggests that the CNS uses a cosine tuning function on the torque plane (T(k), T(h)) to recruit muscles. Interestingly, the muscle's preferred direction (PD) defined as the direction where it is maximally active on the torque plane deviated from its own mechanical pulling direction (MD). This deviation was apparent in the mono-articular knee extensor (MD = 0 degrees , whereas PD = 14.1 +/- 3.7 degrees for vastus lateralis) and in the mono-articular hip extensor (MD = 90 degrees, whereas PD = 53.4 +/- 6.4 degrees for gluteus maximus). Such misalignment between MD and PD indicates that the mono-articular muscle's activation level depends on the torque of the joint that it does not span. Practical implications of this observation for the motor control studies were discussed. We also demonstrated that the observed shift from the MD to the PD is plausible in the configuration of our musculo-skeletal system and that the experimental results are likely to be explained by the CNS process to minimize the variability of the endpoint force vector under the existence of signal-dependent noise.

Adult↗

Kinematic and dynamic synergies of human precision-grip movements.

We analyzed the adaptability of human thumb and index finger movement kinematics and dynamics to variations of precision grip aperture and movement velocity. Six subjects performed precision grip opening and closing movements under different conditions of movement velocity and movement aperture (thumb and index finger tip-to-tip distance). Angular motion of the thumb and index finger joints was recorded with a CyberGlove and a three-dimensional biomechanical model was used for solving the inverse dynamics problem during precision grip movements, i.e., for calculating joint torques from experimentally obtained angular variations. The time-varying joint angles and joint torques were analyzed by principal-component analysis to quantify the contributions of individual joints in kinematic and dynamic synergies. At the level of movement kinematics, we found subject-specific angular contributions. However, the adaptation to large aperture, achieved by an increase of the relative contribution of the proximal joints, was subject-invariant. At the level of movement dynamics, the adaptation of thumb-index finger movements to task constraints was similar among all subjects and required the linear scaling of joint torques, the synchronization of joint torques under high velocity conditions, and a flexible redistribution of joint torques between the proximal joint of the thumb and that of the index finger. This work represents one of the first attempts at calculating the joint torques during human precision-grip movements and indicates that the dynamic synergies seem to be remarkably simple compared with the synergies found for movement kinematics.

Adult↗

Two functional muscle groupings during postural equilibrium tasks in standing cats.

1. This study examined the relation between electromyographic (EMG) activation and the contact force and joint torques of the left hindlimb during postural equilibrium tasks in the standing cat. It is the appropriate application of force by the limbs against the support surface that allows the animal to control its center of mass and maintain equilibrium. 2. Cats were trained to stand quietly on a moveable force platform. During quiet stance, the cat was perturbed by a platform translation in each of 12 directions evenly spaced in the horizontal plane. EMG activity of mono- and biarticular thigh muscles, three-dimensional ground reaction force under the paw (contact force), and kinematics of the hindlimb segments were recorded Net joint torques were computed using inverse dynamics. The analysis focused on the functional organization of the rapid, automatic postural response in relation to the sagittal plane contact force and joint torques. 3. The muscles of the thigh were subdivided into two functional groups, based on the relationship of the evoked response to the various components of the sagittal plane contact force or joint torques. The first group, consisting of the monoarticular and some biarticular muscles, was correlated with the vertical force component, Fz. The second group, consisting of a separate group of biarticular muscles, was correlated with the difference between knee and hip torque. This torque difference is a function of both sagittal plane force components, Fz and Fy, and is related to contact force direction. 4. It is suggested that this subdivision of muscle activations reflects a neural strategy of parallel control of the two muscle groups in relation to their influence on Fz and Fy. Such a control mechanism could be a strategy for simplifying the control of the multisegmented limb in contact force tasks such as maintaining postural equilibrium.

Animals↗

An unlearned principle for controlling natural movements.

Recently, Gottlieb and colleagues discovered a linear relation between elbow and shoulder dynamic torque in natural pointing movements in the sagittal plane. The present study investigates if the process of learning to reach involves discovering this linearity principle. We inspected torque data from four infants who were learning to reach and grab a toy in front of them. In a longitudinal study, we collected data both in the period before and after they performed their first successful reaches. Torque profiles at the shoulder and elbow were typically multipeaked and became more and more biphasic toward the end of the first year of life. Torques at the shoulder and elbow were correlated tightly for movements in the prereaching period as well as for reaches later in the year. Furthermore, slopes of a regression of shoulder dynamic torque on elbow dynamic torque were remarkably constant at a value approximately 2.5-3.0. If linear synergy is used by the nervous system to reduce the controlled degrees of freedom, it will act as a strong constraint on the complex of possible coordination patterns for arm movement early in life. Natural reaching movements can capitalize on this constraint because it simplifies the process of learning to reach.

Aging↗

Control of the wrist in three-joint arm movements to multiple directions in the horizontal plane.

In a reaching movement, the wrist joint is subject to inertial effects from proximal joint motion. However, precise control of the wrist is important for reaching accuracy. Studies of three-joint arm movements report that the wrist joint moves little during point-to-point reaches, but muscle activities and kinetics have not yet been described across a range of movement directions. We hypothesized that to minimize wrist motion, muscle torques at the wrist must perfectly counteract inertial effects arising from proximal joint motion. Subjects were given no instructions regarding joint movement and were observed to keep the wrist nearly motionless during center-out reaches to directions throughout the horizontal plane. Consistent with this, wrist muscle torques exactly mirrored interaction torques, in contrast to muscle torques at proximal joints. These findings suggest that in this reaching task the nervous system chooses to minimize wrist motion by anticipating dynamic inertial effects. The wrist muscle torques were associated with a direction-dependent choice of muscles, also characterized by initial reciprocal activation rather than initial coactivation to stiffen the wrist joint. In a second experiment, the same pattern of muscle activities persisted even after many trials reaching with the wrist joint immobilized. These results, combined with similar features at the three joints, such as cosine-like tuning of muscle torques and of muscle onsets across direction, suggest that the nervous system uses similar rules for muscles at each joint, as part of one plan for the arm during a point-to-point reach.

Arm↗

Sex differences in rabbit masseter muscle function.

The proportions of fibers of different phenotypes in the rabbit masseter muscle differ strikingly in adult males and females. Muscles from females contain similar proportions of small fibers that express both the slow/beta and cardiac alpha myosin heavy chain (MyHC) isoforms and larger fibers containing the IIa MyHC isoform. In muscles from males, nearly 80% of fibers are of the IIa phenotype. To evaluate the functional significance of these sex differences, we used finely graded intramuscular microstimulation to study the contractile properties of masseter motor units in >6-month-old male and female rabbits. Twitch forces and torques in males were significantly greater in magnitude than those of females. Greater proportions of units that produced larger forces/torques were encountered in the males. The same motor units produced force or torque more rapidly in males than in females, principally because units in which twitch rise times were >22 ms were found only in females. The forces applied to the mandible and the torques generated about the right mandibular condyle were studied during cortically evoked rhythmic activation of the masticatory muscles. The overall range of torque rise times and the magnitudes of the peak torques did not differ between sexes. The mean rise time was significantly shorter and the mean peak torque was significantly greater in males. We conclude that sex differences in fiber phenotype proportions are reflected in sex differences in motor unit properties and in the function of these motor units during rhythmic activation.

Animals↗