Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Polystyrenes”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90Linked to original sources

Electron beam transport in heterogeneous slab media from MeV down to eV.

An optimized Monte Carlo method based on the null collision technique and on the treatment of individual interactions is used for the simulation of the electron transport in multilayer materials from high energies (MeV or several hundred of keV) down to low cutoff energies (between 1 and 10 eV). In order to better understand the electron transport and the energy deposition at the interface in the composite application framework, two layer materials are considered (carbon and polystyrene with densities of 1.7 g cm(-3) and 1.06 g cm(-3), respectively) under two slab or three slab configurations as, e.g. a thin layer of carbon sandwiched between two polystyrene layers. The electron-matter cross-sections (electron-carbon and electron-polystyrene) used in the case of pure material (carbon and polystyrene) as well as our Monte-Carlo code have been first validated. The boundary interface layer is considered without any mean free path truncation and with a rigorous treatment of the backscattered and also the forward scattered electrons from one layer to another. The large effect of the choice of a low cutoff energy and the dissociation process consideration are also clearly shown in the heterogeneous multi-layer media more particularly on the secondary electron emission, inelastic collision number and energy spectra.

Carbon↗

Measurement of particle size distribution in multilayered skin phantoms using polarized light spectroscopy.

We report on the ability to use polarized light to measure the particle size distribution of thin layers of polystyrene microspheres on top of a solid Intralipid phantom. The optical properties of each layer were adjusted to match the absorption and scattering properties of the epidermis (polystyrene layer) and dermis (Intralipid layer). Polarized light was used to discriminate between light scattered from the top layer of polystyrene and the lower layer of Intralipid. In this paper we also study the effect of the thickness of the top layer on the ability to reconstruct the polystyrene size distribution.

Biophysical Phenomena↗

CO-alkene polymers are biocompatible scaffolds for primary urothelial cells in vitro and in vivo.

OBJECTIVE: To investigate CO-alkene polymers, novel synthetic nonbiodegradable polymers, as a potential biomaterial for urological applications. MATERIALS AND METHODS: Porcine urothelial cells were seeded on cover glasses (96 wells; 10 000 cells/well) coated with CO-alkene polymers [propylene/N-Acetyl-O'-(hex-5-enyl)-l-tyrosine ethyl ester/CO (PTCO) and hexene-CO (HxCO)]. The following conditions were investigated: cells seeded; (i) on PTCO, (ii) on HxCO, (iii) in PTCO-conditioned medium, (iv) in HxCO-conditioned medium, (v) on glass without polymers, (vi) on polystyrene, and (vii) on polystyrene treated with 1.25% NaCl (toxic control). Cell counts, cell death detection assay, and a cell activity assay (XTT, a tetrazolium-based colorimetric assay) were performed after 3, 6 and 9 days. Urothelial-cell seeded-PTCO films (0.5 x 10(6) cells/cm(2)) were implanted into the subcutaneous space of athymic mice for up to 12 weeks and unseeded PTCO polymers were implanted as a negative control. RESULTS: The urothelial cell adherence rates on the polymers were similar to those for glass and polystyrene. The cell activity (XTT assay) was higher in cells seeded on the polymers than in cells seeded on polystyrene and glass after 3 and 6 days. There were no significant differences between the apoptosis rates of all groups at the given sample times, except for the high levels in the toxic control. In vivo the urothelial cells survived on the polymers for 12 weeks with no adverse reactions in any of the mice. CONCLUSIONS: CO-alkene polymers are biocompatible materials for urothelial cells in vitro and in vivo, and thus are potential biomaterials for the urogenital tract.

Alkenes↗

Influence of phantom material and phantom size on radiographic film response in therapy photon beams.

The energy dependence of radiographic film can introduce dosimetric errors when evaluating photon beams. The variation of the film response, which is attributed to the changing photon spectrum with depth and field size, has been the subject of numerous publications in recent years. However, these data show large unexplained differences in the magnitude of this variation among independent studies. To try to resolve this inconsistency, this study assesses the dependence of radiographic film response on phantom material and phantom size using film measurements and Monte Carlo calculations. The relative dose measured with film exposed to 6 MV x rays in various phantoms (polystyrene, acrylic, Solid Water, and water; the lateral phantom dimensions vary from 25 to 50 cm square; backscatter thickness varies from 10 to 30 cm) is compared with ion chamber measurements in water. Ranges of field size (5 x 5 to 40 x 40 cm2) and depth (dmax to 20 cm) are studied. For similar phantom and beam configurations, Monte Carlo techniques generate photon fluence spectra from which the relative film response is known from an earlier study. Results from film response measurements agree with those derived from Monte Carlo calculations within 3%. For small fields (< or = 10 x 10 cm2) and shallow depths (< or = 10 cm) the film response variation is small, less than 4%, for all phantoms. However, for larger field sizes and depths, the phantom material and phantom size have a greater influence on the magnitude of the film response. The variation of film response, over the ranges of field sizes and depths studied, is 50% in polystyrene compared with 30% in water. Film responses in Solid Water and water phantoms are similar; acrylic is between water and polystyrene. In polystyrene the variation of film response for a 50 cm square phantom is nearly twice that observed in a 25 cm square phantom. This study shows that differences in the configuration of the phantoms used for film dosimetry can explain much of the inconsistency for film response reported in the literature.

Dose-Response Relationship, Radiation↗

Comparison of IAEA 1987 and AAPM 1983 protocols for dosimetry calibration of radiotherapy beams.

The IAEA 1987 protocol is an international protocol which has made a number of improvements over the AAPM 1983 protocol for calibration of high-energy photon and electron beams. We present a detailed numerical comparison between the two protocols by calculating (i) Ngas and ND for PTW (PMMA wall), Capintec (air-equivalent plastic wall) and NEL (graphite wall) Farmer type ionization chambers for 60Co gamma rays; (ii) dose-to-water with chamber in water irradiated by 4- or 25-MV x rays; (iii) dose-to-water with chamber in water, PMMA, and polystyrene phantoms irradiated by 5- and 10-MeV electrons; and (iv) dose-to-water with chamber in water irradiated by 20-MeV electrons. For photons, the IAEA protocol gives results which are in good agreement with the AAPM protocol; on average the IAEA results are 0.6% smaller than the AAPM results while discrepancies between the two are in the range of -0.4% to -1.2%. For 10-MeV electrons also, the IAEA protocol gives results which are in excellent agreement with the AAPM protocol; on average the IAEA results are 0.3% smaller than the AAPM results while discrepancies between the two are in the range of -1.0% to +0.5%. In contrast to the above, for 5-MeV electrons, the IAEA protocols give results smaller than the AAPM protocol by 2.0% on average with discrepancies between protocols ranging from -4.1% to -0.7% depending upon the ionization chamber and phantom material used. For 5-MeV electrons, the discrepancies are particularly large for polystyrene phantom; the average discrepancies being -1.4%, -1.1%, and -3.6% for water, PMMA, and polystyrene, respectively. If data for 5-MeV electrons with polystyrene phantom are excluded, then the overall agreement between the two protocols for photons and electrons is within the range of -1.9% to +0.5%. Principal reasons for the observed discrepancies are (i) IAEA uses the correct expression for ND resulting in up to +0.8% correction; (ii) IAEA uses the most recent stopping power ratio for graphite-to-air resulting in up to +0.5% correction; (iii) IAEA uses a correction of up to +0.8% for the central electrode which AAPM ignores; (iv) the present estimates of the percent depth doses which arise from the differences in measurement depths in the two protocols; and (v) IAEA uses measured values of the fluence correction factor while AAPM uses a theoretical estimate resulting in corrections of up to -2.2%.

Calibration↗

Simple calculation of the electron-backscatter factor.

The authors have studied the dependence of the electron-backscatter factor (EBF) on mean electron energy and on backscatterer atomic number by using the semiempirical depth-dose code EDMULT. A plane-parallel electron beam is assumed to be normally incident on a polystyrene slab, which is backed with a layer (backscatterer) of different materials of effectively semi-infinite thickness. A small air cavity to measure ionization is embedded in the polystyrene slab at the boundary facing the backscatterer. The EBF is defined as the ratio of the ionization with the backscatterer to the ionization with a full polystyrene medium, and is approximated by the ratio of the doses computed at the depth of the cavity. Values of EBF obtained show trends similar to the experimental data of Klevenhagen et al. [Phys. Med. Biol. 27, 263-373 (1982)], although the former are generally lower than the latter. When the typical energy spread of clinical electron beams is taken into account, the difference between the experimental and the calculated values is reduced. The present results also show the same trend of increase of the backscatter factor with increasing energy as observed by Klevenhagen et al. in some series of measurements for the lead backscatterer at the lowest energies. This is explained by the rapid buildup of the dose with depth for electrons of low initial energies incident on the full polystyrene medium.

Electrons↗

Enzyme-linked immunosorbent assay with Brucella native hapten polysaccharide and smooth lipopolysaccharide.

Brucella melitensis native haptens (NH) are polysaccharides identical to the O-side chain of the smooth lipopolysaccharide (S-LPS) (E. Moreno, H. Mayer, and I. Moriyón, Infect. Immun. 55:2850-2853, 1987) which precipitate with sera from infected cattle but not from strain 19-vaccinated cattle. In the present work, NH was extracted by the hot-water method (R. Díaz, J. Toyos, M.D. Salvo, and M.L. Pardo, Ann. Rech. Vet. 12:35-39, 1981) and purified free of S-LPS and protein. Purified NH lacked the ability to coat polystyrene and sheep erythrocytes. In contrast, NH acylated with stearoyl chloride bound to both polystyrene and erythrocytes. By hemagglutination and enzyme-linked immunosorbent assay (ELISA), S-LPS and acylated NH gave similar results with blood sera from brucellosis-free, strain 19-vaccinated, and infected cattle. Moreover, a significant correlation between the results of NH ELISA and S-LPS ELISA was demonstrated with milk sera. However, in a competitive ELISA with milk sera, S-LPS in the liquid phase abrogated the binding of antibodies to acylated NH adsorbed to polystyrene, while NH in the liquid phase did not influence the binding of antibodies to polystyrene-adsorbed S-LPS. It is hypothesized that the different precipitations of NH and S-LPS with sera from infected or strain 19-vaccinated cattle are due to differences in the affinity of the antibodies produced upon vaccination or infection and in the physical state of aggregation of NH and S-LPS in aqueous solutions.

Animals↗

Intrinsic mechanical properties of the extracellular matrix affect the behavior of pre-osteoblastic MC3T3-E1 cells.

Mechanical cues present in the ECM have been hypothesized to provide instructive signals that dictate cell behavior. We probed this hypothesis in osteoblastic cells by culturing MC3T3-E1 cells on the surface of type I collagen-modified hydrogels with tunable mechanical properties and assessed their proliferation, migration, and differentiation. On gels functionalized with a low type I collagen density, MC3T3-E1 cells cultured on polystyrene proliferated twice as fast as those cultured on the softest substrate. Quantitative time-lapse video microscopic analysis revealed random motility speeds were significantly retarded on the softest substrate (0.25 +/- 0.01 microm/min), in contrast to maximum speeds on polystyrene substrates (0.42 +/- 0.04 microm/min). On gels functionalized with a high type I collagen density, migration speed exhibited a biphasic dependence on ECM compliance, with maximum speeds (0.34 +/- 0.02 microm/min) observed on gels of intermediate stiffness, whereas minimum speeds (0.24 +/- 0.03 microm/min) occurred on both the softest and most rigid (i.e., polystyrene) substrates. Immature focal contacts and a poorly organized actin cytoskeleton were observed in cells cultured on the softest substrates, whereas those on more rigid substrates assembled mature focal adhesions and robust actin stress fibers. In parallel, focal adhesion kinase (FAK) activity (assessed by detecting pY397-FAK) was influenced by compliance, with maximal activity occurring in cells cultured on polystyrene. Finally, mineral deposition by the MC3T3-E1 cells was also affected by ECM compliance, leading to the conclusion that altering ECM mechanical properties may influence a variety of MC3T3-E1 cell functions, and perhaps ultimately, their differentiated phenotype.

Acrylic Resins↗

Adsorption of fibrinogen and some other proteins from blood plasma at a variety of solid surfaces.

Enzyme linked immunosorbent assay (ELISA) was used for the estimation of protein adsorption from blood plasma at some model solid surfaces. The majority of those surfaces were made in the wells of microtiterplates of polystyrene commonly used for ELISA purposes. Three of the model surfaces were made by radio frequency plasma discharge polymerization (RFPD) of the microtiterplates of polystyrene. The monomers we used were diaminocyclohexane, hexamethylenedisiloxane, and acrylic acid. Other surfaces investigated were: unmodified polystyrene, oxidized polystyrene, hydrophilic silicon oxide, and methylized silicon oxide. Two substances, Tween and bovine serum albumin (BSA), for the prevention of unintended adsorption of ELISA conjugate were also tested and the BSA method was found to be superior for this kind of investigation. Human blood plasma at different dilutions was incubated in the surface-modified microtiterplates followed by incubation of rabbit antibodies against fibrinogen (FG), fibronectin (FN), human serum albumin (HSA), complement factor 3 (C3), and immunoglobulin G (IgG). Visualization of bound antibodies was then made by standard ELISA procedure. At low blood plasma concentrations (plasma dil 1/1000), anti-IgG and anti-HSA were detected at high levels at the majority of surfaces. At high blood plasma concentration (plasma dil 1/10), anti-FG dominated at most surfaces. ELISA activity of FN and C3 were low at most of the surfaces at both plasma concentrations. An 'optimum' plasma dilution for the detection of surface bound FG (the Vroman effect) was not found with the use of the ELISA on any of the surfaces except for the silicon oxide surface. This is in contrast to findings by others who had used isotope-labelled fibrinogen diluted in plasma. However, 'false' Vroman effects occurred if nonionic surfactant was used for the prevention of unspecific binding in the ELISA.

Adsorption↗

In vitro biocompatibility of titanium oxide for prosthetic devices nanostructured by low pressure metal-organic chemical vapor deposition.

Metal-Organic Chemical Vapor Deposition (MOCVD) has recently been proposed to coat orthopedic and dental prostheses with metal nanostructured oxide films through the decomposition of oxygenated compounds (single-source precursors) or the reaction of oxygen-free metal compounds with oxygenating agents. The present study was carried out to assess the in vitro biocompatibility in terms of cell proliferation and activation, of commercially pure Ti (control material: TI/MA) coated with nanostructured TiO2 film by MOCVD (Ti/MOCVD) using osteoblast-like cell cultures (MG-63). Evaluations were performed at 3, 7 and 14 days. Cell proliferation showed a similar trend for Ti/MA and TilMOCVD compared to polystyrene; cell number increased with time from seeding to day 7 (p < 0.005), and then decreased progressively until day 14 (ranging from -14% to -47%). The ALP level and OC production showed no significant differences between Ti/MOCVD and Ti/MA at each experimental time. Significantly higher ALP levels were found in Ti/MA at 3 days and in Ti/MOCVD at 7 and 14 days when compared to the polystyrene group. OC production decreased over time and the highest values were observed at 3 days, when it was significantly higher in the Ti/MA than in the polystyrene group (50%, p < 0.05). CICP synthesis was positively affected by the presence of Ti/MOCVD and was higher in Ti/MOCVD than in the polystyrene group. No significant differences were found between Ti/MOCVD and Ti/MA in terms of IL-6 and TGF-beta1 synthesis at any experimental time. In conclusion, the current findings demonstrate that the nanostructured TiO2 coating positively affects the osteoblast-like cell behavior in terms of cell proliferation and activity, thus confirming its high level of in vitro biocompatibility in accordance with expectations.

Biocompatible Materials↗

[Measurement of urine human growth hormone levels by ultra-highly sensitive enzyme immunoassay].

A highly sensitive enzyme immunoassay (EIA) for measurement of urine hGH was set up by a modification of the method of Hashida and Ishikawa, which was a sandwich enzyme immunoassay using anti-hGH antibody coated polystyrene balls and anti-hGH antibody-peroxidase conjugate. Anti-hGH serum was obtained in rabbits by subcutaneous injections of hGH emulsified in complete Freund's adjuvant. In order to reduce non-specific binding to the solid phase, anti-hGH IgG was precipitated from rabbit serum followed by digestion to F(ab')2 and affinity purification. Fab'-peroxidase conjugate was produced by maleimide method. The assay procedure was as follows. 1. 100 microliters of urine samples or hGH standard were incubated with anti-hGH IgG coated polystyrene balls. 2. Polystyrene balls were then incubated with Fab'-peroxidase conjugate. Polystyrene balls were carefully washed three times in saline after incubation with Fab'-peroxidase conjugate, which reduced contamination and non-specific binding. 3. Peroxidase activity bound to the balls was assayed by enzyme reaction using 3(p-hydroxyphenyl) propionic acid as a substrate, and fluorescence intensity was measured by a spectrofluorophotometer (Shimadzu RF-540). Reducing the energy of excitation by setting the slit width of the spectrofluorophotometer at 2nm made it possible to gain stable fluorescence. The minimum detectable quantity of hGH was 30fg/tube in the assay, so that the detection limit was 0.3 pg/ml when 100 microliters of urine samples were used. Coefficient of intra- and inter-assay variation was 6.0% and 8.6%, respectively. The recovery was 98.8 +/- 2.8 (+/- SE) on average. Multiple dilution of acromegalic urine and urine after insulin injection produced dose-response curves parallel to those of the standards. Urine hGH levels in acromegalic patients were significantly greater than those in normal subjects. These findings indicate that sensitive EIA of urine hGH is potentially useful for evaluating the pituitary function.

Chromatography, Affinity↗

Microcarrier culture of hepatocytes in whole plasma for use in liver support bioreactors.

Contact activation of plasma clotting may limit the use of some microcarrier types for hepatocyte attachment in a liver assist device. Activation by seven microcarrier types was studied in plasma containing 2-500 units heparin/mL. Clotting was activated by dextran (Cytodex 1 and 2) and collagen-coated (Cytodex 3) microcarriers at 2-25 units/mL (Cytodex 1) and 2-100 units/mL (Cytodex 2 and 3). There was no activation by polystyrene, gelatin, glass or fibronectin-coated polystyrene microcarriers. Compared with culture medium, incubation of HepG2 cells in plasma did not affect cell viability but increased cell number (56.4 versus 65.1 x 10(4) cells; P less than 0.05) and incorporation of [3H]-amino acids into protein (204913 versus 279624 dpm; P less than 0.05). Polystyrene-attached cells demonstrated time-linear protein synthesis, glucose and 7-ethoxycoumarin metabolism. We conclude that polystyrene-attached hepatocytes maintain viability and metabolic activity in plasma and are of potential use in a liver support bioreactor.

Artificial Organs↗

[Dendritic cells present particulate E7 protein of human papillomavirus and induce strong immunity].

OBJECTIVE: To investigate the feasibility of using dendritic cell (DC)-beads-antigen (Ag) as novel cancer vaccine form with E7 as the target antigen. METHODS: C57BL/6 mouse was killed and the femora were taken out. Marrow cells were isolated and cultured with IL-3 and granulocyte-macrophage growth stimulating factor (GM-CSF) so as to prepare DCs. Flow cytometry was conducted to analyze the phenotype. FITC-labeled polystyrene beads-ovalbumin (OVA) or polystyrene beads-human papillomavirus (HPV) E7 protein were added into the culture fluid to be co-cultured with the DCs for 3 hours. Flow cytometry was conducted to analyze the up-taking rates of polystyrene beads-OVA and of polystyrene beads-HPV E7 protein by the DCs and B3Z T cell hybridoma cells were co-cultured and then beads-OVA or beads-SIIFEKL polypeptide was added into the culture fluid. The absorbance was read. Twelve mice were injected with DC-beads-OVA, DC-beads-E7, DC-OVA antigen epitope (SIIFEKL), or DC-E7 epitope (RAHYNIVTF) into the plantae and killed in 36 hours to take out the iliac lymph nodes. Flow cytometry was conducted to analyze the phenotypes of the bead-positive cells. Mice were killed 10 days after immunization and their heart blood was collected. Enzyme linked immunosorbent assay was used to detect the levels of antibodies. Immunized and non-immunized mice were killed and their spleens were taken out. ELISPOT was used to detect the number of cells secreting interferon (IFN)gamma. RESULTS: DCs were seen in the culture fluid of mice marrow cells 5 days after culture with IL-3 and GM-CSF. The bead-positive rates of bead-E7 and bead-OVA were 64% +/- 18% and 58% +/- 16% respectively (P > 0.05) in the IL-3DCs. The CD40 expression rate in the bead-positive cells in the graining iliac lymph nodes was significantly higher after feeding by beads-E7 in comparison with that before the feeding (P < 0.05), the NLDC145, and MHC-II expression rates were increased to a certain degree, however the F4/80 expression rate was decreased. The DCs fed with bead-OVA or with OVA antigen epitope SIIFEKL, especially the former, significantly activated the B3Z cells. The serum IgG level in the mice immunized by beads-E7 was significantly increases, the IgM level was increased slightly, however, the IgA level almost remained unchanged. The numbers of IFNgamma SFU in the splenic cells of the mice immunized by DC-bead-OVA and DC-bead-E7 were significantly higher than that in the unimmunized mice, especially those immunized by DC-bead-OVA. CONCLUSION: DCs fed with beads-E7 can migrate to the draining lymph nodes and induce high level humeral and cellular immunity. DC-beads-Ag seems better than DC-epitope according to the strength of induced immunity. DC-beads-Ag may be an ideal vaccine form and can be used to develop other cancer vaccine.

Animals↗

More reliable diagnosis of infection with human immunodeficiency virus type 1 (HIV-1) by detection of antibody IgGs to pol and gag proteins of HIV-1 and p24 antigen of HIV-1 in urine, saliva, and/or serum with highly sensitive and specific enzyme immunoassay (immune complex transfer enzyme immunoassay): a review.

Ultrasensitive enzyme immunoassays (immune complex transfer enzyme immunoassays) were developed for antibody IgGs to HIV-1 using recombinant reverse transcriptase (rRT), p17 (rp17), and p24 (rp24) as antigens. Antibody IgGs were reacted with 2,4-dinitrophenyl-recombinant antigens and recombinant antigen-beta-D-galactosidase conjugates, and the immune complexes formed, comprising the three components, were trapped onto polystyrene beads coated with (anti-2,4-dinitrophenyl group) IgG. After washing, the immune complexes were eluted from the polystyrene beads with excess of epsilon N-2,4-dinitrophenyl-L-lysine and were transferred to clean polystyrene beads coated with (antihuman IgG gamma-chain) IgG. beta-D-Galactosidase activity bound to the last polystyrene beads was assayed by fluorometry. By transfer of the immune complexes from one solid phase to another, the nonspecific binding of the beta-D-galactosidase conjugates was minimized and the sensitivity was markedly improved. The immune complex transfer enzyme immunoassays using rRT, rp17, and rp24 as antigens were 300-1,000-fold, 1,000-3,000-fold, and 30-100-fold, respectively, more sensitive than Western blotting for the corresponding antigens and 10-300-fold more sensitive than a conventional ELISA and a gelatin particle agglutination test. For urine (100 microliters), whole saliva (1 microliter), and serum (1 microliter) samples, the sensitivity and specificity of the immune complex transfer enzyme immunoassay using rRT as antigen were both 100%. However, for urine samples in which the specific activities of antibody IgG to RT, p17, and p24 were much lower than those in serum samples probably due to degradation by the kidney, a longer assay of bound beta-D-galactosidase activity or/and a concentration process for urine was required. The use of more than 1 microliter of whole saliva was recommended for reliable diagnosis of the infections, whereas 1 microliter of serum was sufficient for the purpose. The positivity with rRT as antigen could be confirmed by demonstration of antibody IgGs to p17 and p24 in most of the urine, whole saliva, and serum samples. In HIV-1 seroconversion serum panels, antibody IgG to p17 was detected as early as or even earlier than antibodies to HIV-1 by a conventional ELISA or/and a gelation particle agglutination test, whereas antibody IgGs to RT and p24 were detected as early as or later than antibody IgG to p17. Thus the uses of rRT and rp17 as antigens were advantageous over that of the other antigens for randomly collected serum samples probably long after the infection and serum samples at early stages of the infection, respectively. On the basis of these results and other reports, the immune complex transfer enzyme immunoassay was developed for simultaneous detection of p24 antigen and antibody IgGs to RT and p17 in a single assay tube, and the window period (8 weeks, although widely variable), during which diagnosis of HIV-1 infection is not possible due to the absence of detectable antibodies to HIV-1, was shortened by 2 weeks. As a result, the simultaneous detection made possible not only as early diagnosis as that by detection of p24 antigen, but also as reliable diagnosis as that by detection of antibodies to HIV-1. Finally, the immune complex transfer enzyme immunoassay has been recently improved so as to be performed within shorter periods of time (2-3 hr) with higher sensitivity, and testing many samples has become easy.

Acquired Immunodeficiency Syndrome↗

Particle classification from light scattering with the scanning flow cytometer.

BACKGROUND: The differential light-scattering pattern, an indicatrix, provides the most complete characterization of the optical properties of a particle. Particle classification can be performed on the basis of particle parameters retrieved from the indicatrices. This classification extends the ability of flow cytometry in particle recognition. METHODS: The scanning flow cytometer (SFC) permits an acquisition of traces of light scattering signals, i.e., native SFC traces, from single particles. The acquired native SFC traces are transformed into indicatrices. The performance of the SFC in measurements of indicatrices has been demonstrated for the following particles: lymphocytes, erythrocytes, polystyrene particles, and milk-fat particles. RESULTS: The structure and profile of the indicatrix for each particle type have been found to be unique. Classification of polystyrene particles has been performed on the basis of the map formed by particle refractive index and size. The polystyrene particles were classified using this map into different size categories ranging from 1.4-7 microm, with a size deviation of 0.07 microm. CONCLUSIONS: The method based on analysis of native SFC traces shows better performance in particle classification than the method based on the particle refractive index and size map. The classification performance of the SFC will be useful, for example, for particle sorting and particle identification, and with additional fluorescent measurements may have applications in multiparameter particle-based immunoassay.

Animals↗

A flow cytometric immunoassay to quantify adsorption of complement activation products (iC3b, C3d, SC5b-9) on artificial surfaces.

Crosslinked agarose microspheres and various polystyrene microspheres were analyzed for complement components after incubation with serum at 37 degrees C for times up to 2 h. Quantification involved direct flow cytometric analysis of the beads after the bound complement proteins were indirectly fluorescently tagged by use of a monoclonal antibody against a complement protein: C5b-9, iC3b, C3d, C4d, Bb, C3a, and C1q. Calibration with fluorescein microbead standards demonstrated that the membrane attack complex (SC5b-9) was surface bound on all surfaces and that the surface concentration gradually increased to levels as high as 0.5 micrograms/cm2. Further, the surface bound represented a substantial percentage of the total generated. The iC3b level on polystyrene beads rapidly reached 0.09 micrograms/cm2 and the C3d levels were an order of magnitude less. On agarose beads the iC3b levels continually rose to 0.17 micrograms/cm2 and, as before, the C3d levels were substantially lower. The surface concentration of C4d and Bb on both surfaces were significant but less than 1.0 ng/cm2. There was minimal evidence of C3a and C1q adsorption for any surface. Use of amino-polystyrene beads moderately reduced the level of bound iC3b, C3d, and SC5b-9, whereas carboxylated beads reduced the levels by almost a factor of two. The appreciable amounts of iC3b and SC5b-9 consistently noted on the artificial surfaces tested in this paper suggests that for these two activation products in vitro analysis of material induced complement activation should also include surface analysis.

Adsorption↗

Possible role of alpha-1-microglobulin in mediating bacterial attachment to model surfaces.

Urine proteins in the molecular weight range of 9-137 kDa deposit to an equal extent from pooled human urine onto glass (12.7 +/- 1.9 micrograms/cm) and polystyrene (11.8 +/- 1.8 micrograms/cm). Selective desorption of the proteins was achieved by washing with water or water/isopropanol mixtures. Irrespective of the washing process, proteins of molecular weight greater than 90 kDa remained associated with both surfaces while water washings alone removed most low molecular weight material. A 29 kDa protein, alpha-1-microglobulin, was removed from glass by water washing but required a 30% (v/v) isopropanol wash to desorb from polystyrene, implying attachment via hydrophobic bonding. The adhesion to polystyrene surfaces of Pseudomonas aeruginosa B4, a clinical isolate from a urinary tract infection (UTI), was strongly associated with the presence of alpha-1-microglobulin, which may be acting as a mediator of bacterial adhesion.

Adsorption↗

Rapid formation of the immune complexes on solid phase in the immune complex transfer enzyme immunoassays for HIV-1 p24 antigen and antibody IgGs to HIV-1.

In order to perform the immune complex transfer enzyme immunoassays for HIV-1 p24 antigen and antibody IgGs to HIV-1 p17, reverse transcriptase and gp41 antigens as rapidly as possible, methods for rapid formation of the immune complexes on solid phase are described. HIV-1 p24 antigen was reacted with monoclonal anti-p24 Fab'-beta-D-galactosidase conjugate at a high concentration and subsequently with polystyrene beads coated successively with affinity-purified (anti-2,4-dinitrophenyl group) IgG and 2,4-dinitrophenyl-biotinyl bovine serum albumin-affinity-purified anti-p24 Fab' conjugate. Antibody IgGs to HIV-1 were reacted with polystyrene beads coated successively with affinity-purified (anti-2,4-dinitrophenyl group) IgG and 2,4-dinitrophenyl-HIV-1 antigen conjugates and subsequently with HIV-1 antigen-beta-D-galactosidase conjugates. The periods of time used for the formation of the immune complexes comprising the three components on the polystyrene beads (15-30 min) were much shorter than those used in the previous immune complex transfer enzyme immunoassays (90-300 min), and the sensitivities of the present and previous immune complex transfer enzyme immunoassays were similar. The detection limit of the HIV-1 p24 antigen by the present and previous methods were similar (3 to 10 zmol/assay).

Adult↗