Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “MAGNETISM”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90Linked to original sources

Intracranial assessment of incontinentia pigmenti using magnetic resonance imaging, angiography, and spectroscopic imaging.

OBJECTIVE: To evaluate patients with incontinentia pigmenti for evidence of cerebrovascular disease using magnetic resonance imaging techniques. DESIGN: A prospective case series of seven patients (four of whom were related) with incontinentia pigmenti using magnetic resonance imaging, magnetic resonance angiography, and multislice proton (1H) magnetic resonance spectroscopic imaging. SETTING: The Johns Hopkins Medical Institutions, Baltimore, Md, a tertiary, referred care center. PATIENTS: Seven patients with a diagnosis of incontinentia pigmenti. RESULTS: Five of the seven patients had abnormal magnetic resonance imaging consistent with small-vessel occlusions. Of these five patients, four had normal magnetic resonance angiography and spectroscopic imaging, and one patient had reduced middle cerebral artery flow on magnetic resonance angiography and increased lactate level in the cerebrospinal fluid on spectroscopic imaging. The remaining two patients had normal magnetic resonance imaging and spectroscopic imaging. Of these two patients, one had normal magnetic resonance angiography and the other had a right supraclinoid internal carotid aneurysm. There was substantial concordance between clinical (ophthalmic/neurologic) and imaging abnormalities. CONCLUSIONS: The central nervous system changes in patients with incontinentia pigmenti may represent the result of small-vessel occlusive phenomena in the brain. These central nervous system findings may share a common pathophysiologic state with the vascular occlusive disease seen in the retinas of these patients. The changes in the retinal vasculature may serve as a potential marker for central nervous system disease. Physicians should be aware of the systemic and debilitating nature of incontinentia pigmenti.

Adult↗

Behavioural evidence that magnetic field effects in the land snail, Cepaea nemoralis, might not depend on magnetite or induced electric currents.

Although extremely low frequency (ELF) magnetic fields (<300 Hz) appear to exert a variety of biological effects, the magnetic field sensing/transduction mechanism(s) remains to be established. Here, using the inhibitory effects of magnetic fields on endogenous opioid peptide-mediated "analgaesic" response of the land snail, Cepaea nemoralis, we addressed the mechanism(s) of action of ELF magnetic fields. Indirect mechanisms involving both induced electric fields and direct magnetic field detection mechanisms (e.g., magnetite, parametric resonance) were evaluated. Snails were exposed to a static magnetic field (B(DC) = 78 +/- 1 mu T) and to a 60 Hz magnetic field (B(AC) = 299 +/- 1 mu T peak) with the angle between the static and 60 Hz magnetic fields varied in eight steps between 0 degrees and 90 degrees. At 0 degrees and 90 degrees, the magnetic field reduced opioid-induced analgaesia by approximately 20 percent, and this inhibition was increased to a maximum of 50 percent when the angle was between 50 degrees and 70 degrees. Because B(AC) was fixed in amplitude, direction, and frequency, any induced electric currents would be constant independent of the B(AC)/B(DC) angle. Also, an energy transduction mechanism involving magnetite should show greatest sensitivity at 90 degrees. Therefore, the energy transduction mechanism probably does not involve induced electric currents or magnetite. Rather, our results suggest a direct magnetic field detection mechanism consistent with the parametric resonance model proposed by Lednev.

Animals↗

Modeling magnetization transfer using a three-pool model and physically meaningful constraints on the fitting parameters.

A model for water-macromolecular magnetization transfer is presented which addresses the mechanism of coupling between the hydrogen populations and the extraction of physically meaningful parameters from experimental magnetization transfer data. Both physical exchange between bulk-solvent and site-specific hydration-layer hydrogens and intermolecular magnetic dipolar coupling between these specific hydration-layer-solvent and macromolecular hydrogens are explicitly included, leading to a three-pool model for magnetization transfer. It is shown that the three-pool model is well approximated by a two-pool model for coupling between the bulk-solvent and macromolecular hydrogens when the dipolar-coupled solvent hydrogens are a small fraction of the total solvent, and the solvent-macromolecular coupling constant includes both dipolar magnetic, kappa(dip), and physical exchange, kappa(ex), coupling rates. The model is also extended to multiple solvent systems. The model results in a set of coupled equations that predict magnetization transfer spectra as a function of temperature and composition. Physically meaningful constraints on the coupling and relaxation parameters are established for systems in which magnetization transfer has been observed including solvated cross-linked proteins and lipid bilayers. Using parameter estimates based on these constraints, empirical magnetization transfer spectra are well predicted by the model. It is found that the degree of magnetization transfer becomes independent of kappa(dip) and kappa(ex) when these parameters become greater than about 50 s(-1). In the semi-rigid cross-linked protein systems where the mobility of the macromolecular matrix is insensitive to temperature, the magnitude of the observed magnetization transfer is consistent with being limited by the intermolecular dipolar coupling and spin-lattice relaxation in the bulk-solvent phase.

Journal Article↗

Effects of a static magnetic field of either polarity on skin microcirculation.

Our specific aim was to investigate whether a local static magnetic field of a permanent magnet, of either pole, affects resting skin blood perfusion. This was done by measuring skin blood perfusion (SBF) by laser-Doppler in dorsum skin of 2nd and 4th fingers of the nondominant hands of 12 volunteers. Both fingers were first exposed to sham magnets, and then the 2nd finger was exposed alternately to north and south poles of a neodymium magnet that produced a field of 4024 G at the palmar part of the finger and a field of 879 +/- 52 G at the site of finger dorsum SBF measurement. Each of the three exposure intervals was 15 min. SBF values were analyzed by first computing the average SBF during the last 5 min of each of the three 15-min exposure intervals. These SBF averages were initially tested for magnet or magnet-pole effects by analysis of variance for repeated measures with finger as a factor, using SBF values for each finger as the test variable. Results of this analysis revealed a large variability in finger SBF among subjects and no significant difference in SBF between exposure conditions (P = 0.705) or any significant interaction between SBF and finger (P = 0.396). However, when intersubject variability was reduced by using the flow difference between treated and nontreated fingers in each exposure interval as the test variable, a statistically significant effect (P = 0.016) attributable to magnet exposure was uncovered. This effect was a reduction in resting SBF in the magnet-exposed fingers that was similar for north and south pole magnet exposure. The present findings are the first to demonstrate a direct effect of locally applied magnets on human skin blood perfusion.

Adult↗

Suppression of drinking by exposure to a high-strength static magnetic field.

High-strength static magnetic fields of 7 T and above have been shown to have both immediate and delayed effects on rodents, such as the induction of locomotor circling and the acquisition of conditioned taste aversions. In this study, the acute effects of magnet field exposure on drinking were examined. Exposure to a 14.1-T magnetic field for as little as 5 min significantly decreased the amount of a glucose and saccharin solution (G+S) consumed by water-deprived rats over 10 min. The decreased intake could be accounted for largely, but not entirely, by an increase in the latency of magnet-exposed rats to initiate drinking. When intake was measured for 10-60 min after the initiation of drinking, thus controlling for increased latency, magnet-exposed rats still consumed less G+S than sham-exposed rats. The increased latency was not due simply to an inability of magnet-exposed rats to reach the elevated sipper tube of the G+S bottle, providing rats with long tubes that could be reached without raising their heads normalized intake but latency was still increased. The increased latency and decreased intake appeared to be secondary to somatic effects of magnet exposure, however, because during intraoral infusions magnet-exposed rats consumed the same amount of G+S with the same latency to reject as sham-exposed rats. The suppression of drinking by magnetic field exposure is consistent with the acute effects of other aversive stimuli, such as whole-body rotation, on short-term ingestion. These results add to the evidence that high-static strength magnetic fields can have behavioral effects on rodents.

Animals↗

Effects of different frequencies of transcranial magnetic stimulation (TMS) on the forced swim test model of depression in rats.

BACKGROUND: Repetitive transcranial magnetic stimulation has been demonstrated in humans as well as in animal models to have an antidepressant effect, but the optimal frequency of stimulation is not known. We examined this question in a rat model of depression. METHODS: Young male Sprague-Dawley rats were allocated to two placebo (restraint and sham transcranial magnetic stimulation), one active control (imipramine), and four transcranial magnetic stimulation groups at 1, 5, 15 and 25 Hz and 1000 stimuli each. The Porsolt Swim Test was performed on day 1 (experiment 1). In an extension (experiment 2), the treatments were repeated on days 2 through 5, and the Swim Test repeated on days 3, 5, and 7. RESULTS: After one treatment session, all transcranial magnetic stimulation groups had significantly reduced immobility times compared with sham stimulation (p =.000), but the higher frequencies (15 and 25 Hz) did not differ significantly from lower (1 and 5 Hz) frequencies. After three sessions, all transcranial magnetic stimulation groups were different from placebo, and the rapid transcranial magnetic stimulation groups had lower immobility times than the slow transcranial magnetic stimulation groups (p =.035). After five sessions, only 15- and 25-Hz groups were different from control, and on day 7, only the 25-Hz group had reduced immobility. There was an overall difference between fast and slow transcranial magnetic stimulation (p =.010), and 1 Hz was different from the other three transcranial magnetic stimulation conditions (p =.016). CONCLUSIONS: Repetitive transcranial magnetic stimulation reduces immobility time in the Forced Swim Test model of depression, suggesting an antidepressant effect, which is evident at a range (1-25 Hz) of frequencies. With repeated administration, the findings suggest that the antidepressant effect of the higher frequencies, as for imipramine, is likely to be sustained, although the model used for this (i.e., repeating the Swim Test) requires further validation.

Animals↗

Intensity of electric and magnetic fields from power lines within the business district of 60 Ontario communities.

Electric and magnetic fields were measured during the summer of 1998 in south-central Ontario within the business district of 60 communities, ranging in size from 1000 to 2.3 million people. The mean magnetic flux density for the 60 communities was 5.8 mG. Communities with larger populations generally had higher magnetic flux densities than those with smaller populations. Communities with populations above 100,000, between 50,000 and 100,000, between 10,000 and 50,000, and less than 10,000 had mean magnetic flux densities of 14, 7, 4 and 2.4 mG, respectively. The city of Kingston, population 123,000, had the highest mean magnetic flux density (47 mG) while Burks Falls, population 1000, had the lowest (0.8 mG). More than 90% of the sites measured in Kingston, Toronto, Oshawa, London, Pickering Village and Bellville were above 2 mG, the lower limit associated with childhood cancers. In only one community (Burks Falls) were all of the measurements in the business district below 2 mG. Diurnal variations were detected in the magnetic field (but not in the electric field) with highest fields measured during business hours. For electric fields, the mean for the 60 communities was 3.2 V/m. Electric fields were generally low. Eight communities had maximum field strengths above 30 V/m and all of these were associated with overhead wires. In larger communities with underground distribution lines the electric fields were low or undetectable (<0.1 V/m) but the magnetic fields were often high. High electric fields were generally associated with low magnetic fields but the relationship was not sufficiently robust to enable prediction of one from the other. Data for the business district measured during business hours appear to be relatively consistent for both electric field and magnetic flux density over a two-year period. Two classification schemes that can be used independently or in combination are proposed to facilitate community comparisons. One is based on the average intensity of the fields (FI) and the other on the percentage of measurements that exceed a critical limit (CL) that has biological significance. The critical value of 5 V/m is proposed for electric fields and 2 mG for magnetic fields. Both classification schemes use the traffic light analogy for exposure (green-low, amber-medium, red-high exposure) with an additional category (black) for very high exposure. This classification system facilitates information transfer and can easily be understood and used by the public, public utilities, policy makers, and those wanting to practice prudent avoidance.

Cities↗

Single-molecule magnets: site-specific ligand abstraction from [Mn12O12(O2CR)16(H2O)4] and the preparation and properties of [Mn12O12(NO3)4(O2CCH2Bu(t))12(H2O)4].

Site-selective carboxylate abstraction has been achieved from [Mn(12)O(12)(O(2)CR)(16)(H(2)O)(4)] complexes by treatment with HNO(3) in MeCN. The reaction of the R = Ph or CH(2)Bu(t)() complexes with 4 equiv of HNO(3) gives [Mn(12)O(12)(NO(3))(4)(O(2)CR)(12)(H(2)O)(4)] (R = CH(2)Bu(t) (6) or Ph (7)) in analytical purity. Complex 6.MeNO(2) crystallizes in monoclinic space group C2/c with the following cell parameters at -168 degrees C: a = 21.280(5), b = 34.430(8), c = 33.023(8) A, beta = 104.61(1) degrees, V = 23413 A, and Z = 8. The four NO(3)(-) groups are not disordered and are bound in bridging modes at axial positions formerly occupied by bridging carboxylate groups. (1)H NMR spectroscopy in CD(2)Cl(2) and CDCl(3) shows retention of the solid-state structure on dissolution in these solvents. DC magnetic susceptibility (chi(M)) and magnetization (M) studies have been carried out in the 2.00-300 K and 1.0-7.0 T ranges. Fits of M/Nmu(B) versus H/T plots gave S = 10, g = 1.92, and D = -0.40 cm(-1), where D is the axial zero-field splitting parameter. AC magnetic susceptibility studies on 6 have been performed in the 1.70-10.0 K range in a 3.5 Oe field oscillating at frequencies up to 1500 Hz. Out-of-phase magnetic susceptibility (chi(M)' ') signals were observed in the 4.00-8.00 K range which were frequency-dependent. Thus, 6 displays the slow magnetization relaxation diagnostic of a single-molecule magnet (SMM). The data were fit to the Arrhenius law, and this gave the effective barrier to relaxation (U(eff)) of 50.0 cm(-1) (72.0 K) and a pre-exponential (1/tau(0)) of 1.9 x 10(8) s(-1). Complex 6 also shows hysteresis in magnetization versus DC field scans, and the hysteresis loops show steps at regular intervals of magnetic field, the diagnostic evidence of field-tuned quantum tunneling of magnetization. High-frequency EPR (HFEPR) spectroscopy on oriented crystals of complex 6 shows resonances assigned to transitions between zero-field split M(s) states of the S = 10 ground state. Fitting of the data gave S = 10, g = 1.99, D = -0.46 cm(-1), and B(4)(0) = -2.0 x 10(-5), where B(4)(0) is the quartic zero-field coefficient. The combined results demonstrate that replacement of four carboxylate groups with NO(3)(-) groups leads to insignificant perturbation of the magnetic properties of the Mn(12) complex. Complex 6 should now be a useful starting point for further reactivity studies, taking advantage of the good leaving group properties of the NO(3)(-) ligands.

Journal Article↗

Single-molecule magnets: structure and properties of [Mn18O14(O2CMe)18(hep)4(hepH)2(H2O)2](ClO4)2 with spin S = 13.

The reaction of 2-(hydroxyethyl)pyridine (hepH) with a 2:1 molar mixture of [Mn3O(O2CMe)6(py)3]ClO4 and [Mn3O(O2CMe)6(py)3] in MeCN afforded the new mixed-valent (16Mn(III), 2Mn(II)), octadecanuclear complex [Mn18O14(O2CMe)18(hep)4(hepH)2(H2O)2](ClO4)2 (1) in 20% yield. Complex 1 crystallizes in the triclinic space group P. Direct current magnetic susceptibility studies in a 1.0 T field in the 5.0-300 K range, and variable-temperature variable-field dc magnetization studies in the 2.0-4.0 K and 2.0-5.0 T ranges were obtained on polycrystalline samples. Fitting of magnetization data established that complex 1 possesses a ground-state spin of S = 13 and D = -0.18 K. This was confirmed by the value of the in-phase ac magnetic susceptibility signal. Below 3 K, the complex exhibits a frequency-dependent drop in the in-phase signal, and a concomitant increase in the out-of-phase signal, consistent with slow magnetization relaxation on the ac time scale. This suggests the complex is a single-molecule magnet (SMM), and this was confirmed by hysteresis loops below 1 K in magnetization versus dc field sweeps on a single crystal. Alternating current and direct current magnetization data were combined to yield an Arrhenius plot from which was obtained the effective barrier (U(eff)) for magnetization reversal of 21.3 K. Below 0.2 K, the relaxation becomes temperature-independent, consistent with relaxation only by quantum tunneling of the magnetization (QTM) through the anisotropy barrier via the lowest-energy MS = +/-13 levels of the S = 13 spin manifold. Complex 1 is thus the SMM with the largest ground-state spin to display QTM.

Journal Article↗

Magnetoswitchable controlled hydrophilicity/hydrophobicity of electrode surfaces using alkyl-chain-functionalized magnetic particles: application for switchable electrochemistry.

Magnetic nanoparticles consisting of undecanoate-capped magnetite (average diameter approximately 4.5 nm; saturated magnetization, M(s), 38.5 emu g(-1)) are used to control and switch the hydrophobic or hydrophilic properties of the electrode surface. A two-phase system consisting of an aqueous buffer solution and a toluene phase that includes the suspended capped magnetic nanoparticles is used to control the interfacial properties of the electrode surface. The magnetic attraction of the functionalized particles to the electrode by means of an external magnet yields a hydrophobic interface that acts as an insulating layer, prohibiting interfacial electron transfer. The retraction of the magnetic particles from the electrode to the upper toluene phase by means of the external magnet generates a hydrophilic electrode that reveals effective interfacial electron transfer. The electron-transfer resistance and double-layer capacitance of the electrode surface upon the attraction and retraction of the functionalized magnetic particles to and from the electrode, respectively, by means of the external magnet were probed by Faradaic impedance spectroscopy (R(et) = 170 Omega and C(dl) = 40 microF sm(-2) in the hydrophilic state of the electrode and R(et) = 22 k Omega and C(dl) = 0.5 microF sm(-2) in the hydrophobic state of the interface). The magnetoswitchable control of the interface enables magnetic switching of the bioelectrocatalytic oxidation of glucose in the presence of glucose oxidase and ferrocene dicarboxylic acid to "ON" and "OFF" states.

Journal Article↗

Exchange-biased quantum tunnelling in a supramolecular dimer of single-molecule magnets.

Various present and future specialized applications of magnets require monodisperse, small magnetic particles, and the discovery of molecules that can function as nanoscale magnets was an important development in this regard. These molecules act as single-domain magnetic particles that, below their blocking temperature, exhibit magnetization hysteresis, a classical property of macroscopic magnets. Such 'single-molecule magnets' (SMMs) straddle the interface between classical and quantum mechanical behaviour because they also display quantum tunnelling of magnetization and quantum phase interference. Quantum tunnelling of magnetization can be advantageous for some potential applications of SMMs, for example, in providing the quantum superposition of states required for quantum computing. However, it is a disadvantage in other applications, such as information storage, where it would lead to information loss. Thus it is important to both understand and control the quantum properties of SMMs. Here we report a supramolecular SMM dimer in which antiferromagnetic coupling between the two components results in quantum behaviour different from that of the individual SMMs. Our experimental observations and theoretical analysis suggest a means of tuning the quantum tunnelling of magnetization in SMMs. This system may also prove useful for studying quantum tunnelling of relevance to mesoscopic antiferromagnets.

Journal Article↗

Magnetization distribution in the mixed-phase state of hole-doped manganites.

The effect of 'colossal magnetoresistance' (CMR) in hole-doped manganites--an abnormal decrease of resistivity when a magnetic field is applied--has attracted significant interest from researchers in the past decade. But the underlying mechanism for the CMR phenomenon is not yet fully understood. It has become clear that a phase-separated state, where magnetic and non-magnetic phases coexist, is important, but the detailed magnetic microstructure of this mixed-phase state is so far unclear. Here we use electron microscopy to study the magnetic microstructure and development of ferromagnetic domains in the mixed-phase state of La(1-x)Sr(x)MnO3 (x = 0.54, 0.56). Our measurements show that, in the absence of a magnetic field, the magnetic flux is closed within ferromagnetic regions, indicating a negligible magnetic interaction between separated ferromagnetic domains. However, we also find that the domains start to combine with only very small changes in temperature. We propose that the delicate nature of the magnetic microstructure in the mixed-phase state of hole-doped manganites is responsible for the CMR effect, in which significant conduction paths form between the ferromagnetic domains upon application of a magnetic field.

Journal Article↗

The ultimate speed of magnetic switching in granular recording media.

In magnetic memory devices, logical bits are recorded by selectively setting the magnetization vector of individual magnetic domains either 'up' or 'down'. In such devices, the fastest and most efficient recording method involves precessional switching: when a magnetic field B(p) is applied as a write pulse over a period tau, the magnetization vector precesses about the field until B(p)tau reaches the threshold value at which switching occurs. Increasing the amplitude of the write pulse B(p) might therefore substantially shorten the required switching time tau and allow for faster magnetic recording. Here we use very short pulses of a very high magnetic field to show that under these extreme conditions, precessional switching in magnetic media supporting high bit densities no longer takes place at well-defined field strengths; instead, switching occurs randomly within a wide range of magnetic fields. We attribute this behaviour to a momentary collapse of the ferromagnetic order of the spins under the load of the short and high-field pulse, thus establishing an ultimate limit to the speed of deterministic switching and magnetic recording.

Journal Article↗

Magnetically ordered molecule-based assemblies.

The development of molecules and assemblies of molecules exhibiting technologically important bulk properties, such as magnetic ordering, is an important worldwide research focus. Organic- and molecule-based magnets have been discovered and several families have been reported with magnetic ordering temperatures exceeding room temperature and as high as approximately 125 degrees C. Examples of both hard and soft magnets have been reported with coercivities as high at 27 000 Oe (and exceeding commercially available magnets) have been reported. Several examples are based on the radical anion of tetracyanoethylene, S = 1/2 [TCNE].-. The include ionic zero-dimensional (0-D) [FeCp*2]*+[TCNE]*- (Cp* = pentamethylcyclopentadienide), 1-D [MnTPP]+[TCNE]*- [TPP = meso-tetraphenylporphinato] coordination polymers, and 3-D extended network structured M[TCNE](x).ySolvent (M = V, Mn, Fe, Co, Ni, Dy). This Perspective focuses on work in our laboratory that will be discussed at the Dalton Discussion 9 meeting entitled "Functional Molecular Assemblies." In addition to the overview of TCNE-based organic magnets, the targeted design, preparation, and chemical as well as magnetic characterization of a new family of magnets based on S = 3/2 mixed-valent [Ru(II/III)2(O2CR)4]+ (R = Me, Bu(t)) is described. In particular [Ru2(O2CMe)4]3[Cr(CN)6] prepared from aqueous media possess two interpenetrating cubic lattices and magnetically orders at 33 K. In contrast, [Ru2(O2CBu(t))4]3[Cr(CN)6] forms a 2-D layered lattice and orders at 37.5 K. Both exhibit hysteretic behavior, however, this is quite anomalous for the former cubic lattice. This as well as other anomalous magnetic behaviors is attributed to the presence of the second interpenetrating lattice.

Journal Article↗

Within-day variability of magnetic fields among electric utility workers: consequences for measurement strategies.

Occupational exposure to 50-Hz magnetic fields was surveyed among electric utility workers to investigate (1) components of exposure variability, (2) patterns of autocorrelation between short-term measurements, and (3) imprecision and misclassification due to short-term measurements. Spot measurements every 10 seconds during 81 working days were analyzed for 42 electric utility workers from 10 occupational subgroups and during 8 working days for 4 office workers from the same company. For the 8-hour time-weighted average (TWA) magnetic fields, the variability was partitioned into its components: within workers, between workers, and between groups. For spot measurements of magnetic fields, the within-day variance component also was examined. Autocorrelation functions were determined and numbers of short-term measurements necessary for reliable estimates of 8-hour TWA magnetic fields were assessed. Spot measurements of magnetic fields, as well as 8-hour TWA magnetic fields, were approximately log normally distributed among workers. The mean exposure to magnetic fields was 0.47 microT (n = 81 days) in electric utility workers and 0.12 microT (n = 8 days) in office workers. A large fraction, 76% of the spot measurements total variance, could be attributed to variability within days. For the 8-hour TWA magnetic fields, between-group variability was small and of the same magnitude as between-worker variability. Significant autocorrelations between short-term averages of 7.5, 15, and 30 minutes were present, when taken within periods of 30 minutes. One-hour averages showed no autocorrelation. Simulations showed that, due to high within-day variability and autocorrelation, a limited number of short-term measurements of magnetic fields in electric utility workers are likely to result in imprecise estimates of 8-hour TWA magnetic fields. Measurement strategies relying on short-term (spot) measurements are therefore likely to result in misclassification of exposure and consequently absent or spurious exposure-response relations.

Electromagnetic Fields↗

Possible mechanisms by which extremely low frequency magnetic fields affect opioid function.

Although extremely low frequency (ELF, < 300 Hz) magnetic fields exert a variety of biological effects, the magnetic field sensing/transduction mechanism (or mechanisms) remain to be identified. Using the well-defined inhibitory effects that magnetic fields have on opioid peptide mediated antinociception or "analgesia" in the land snail Cepaea nemoralis, we show that these actions only occur for certain frequency and amplitude combinations of time-varying sinusoidal magnetic fields in a manner consistent with a direct influence of these fields. We exposed snails with augmented opioid activity to ELF magnetic fields, which were varied in both amplitude and frequency, along with a parallel static magnetic field. When the peak amplitude (0-547 microT) of a magnetic field of 60 Hz was varied systematically, we observed a nonlinear response, i.e., a nonlinear reduction in analgesia as measured by the latency of a defined response by the snails to a thermal stimulus. When frequency (10-240 Hz) was varied, keeping the amplitude constant (141 microT), we saw significant inhibitory effects between 30 and 35 Hz, 60 and 90 Hz and at 120 and 240 Hz. Finally, when the static field was varied but the amplitude and frequency of the time-varying field were held constant, we observed significant inhibition at almost all amplitudes. This amplitude/frequency "resonance-like" dependence of the magnetic field effects suggests that the mechanism (or mechanisms) of response to weak ELF fields likely involves a direct magnetic field detection mechanism rather than an induced current phenomenon. We examined the implications of our findings for several models proposed for the direct sensing of ELF magnetic fields.

Analgesia↗

Anesthesia for magnetic resonance imaging.

PURPOSE OF REVIEW: This review focuses on the technological principles, safety considerations, monitors and equipment, patient issues, and a general overview of the anesthetic management of both conventional and intraoperative magnetic resonance imaging based on the most recent literature. RECENT FINDINGS: As a diagnostic imaging modality, magnetic resonance imaging remains unparalleled in its diagnostic and clinical value. The clinical applications for magnetic resonance imaging continue to evolve, and include its latest use in minimally invasive procedures as well as in the operating room. Intraoperative magnetic resonance imaging is steadily gaining acceptance for neurosurgical procedures. The safety considerations, monitor and equipment issues for intraoperative magnetic resonance imaging are similar to the conventional setting. However, they differ in their focus on anesthesia management. Most monitoring compatible with magnetic resonance imaging has been available for many years. In the USA, the newest available monitoring option during magnetic resonance imaging is for temperature. This option has been available in other countries for a number of years. A fiberoptic surface sensor provides a safe and accurate monitor of adult, pediatric, and neonatal body temperature. SUMMARY: The magnetic resonance imaging suite is a challenging environment for the anesthesiologist, and carries inherent risks. Several factors account for this, including the remote location, the unique features of the magnetic resonance imaging scanner, and patient-related factors. Understanding the implications of the magnetic resonance imaging environment will facilitate ensuring the safety of the patient and personnel.

Journal Article↗

Magnetic helicity tensor for an anisotropic turbulence.

The evolution of the magnetic helicity tensor for a nonzero mean magnetic field and for large magnetic Reynolds numbers in an anisotropic turbulence is studied. It is shown that the isotropic and anisotropic parts of the magnetic helicity tensor have different characteristic times of evolution. The time of variation of the isotropic part of the magnetic helicity tensor is much larger than the correlation time of the turbulent velocity field. The anisotropic part of the magnetic helicity tensor changes for the correlation time of the turbulent velocity field. The mean turbulent flux of the magnetic helicity is calculated as well. It is shown that even a small anisotropy of turbulence strongly modifies the flux of the magnetic helicity. It is demonstrated that the tensor of the magnetic part of the alpha effect for weakly inhomogeneous turbulence is determined only by the isotropic part of the magnetic helicity tensor.

Journal Article↗