Treatment of fractures with Hirschhorn compression plates.
Explore the source record for details and available documents.
SEARCH · Search PubMed
Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Fifty-one tibial shaft fractures treated by ASIF compression osteosynthesis were seen at follow-up at a median time of 46 weeks after injury. Twenty-four were open fractures and the patients received prophylactic antibiotics. The median stay in hospital was 15 days for open fractures and 6 days for closed fractures. There were complications in 26 cases, with deep infection in 9 cases. At present we cannot advocate the use of ASIF compression osteosynthesis for displaced tibial fractures.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
We reviewed 48 patients with thoracolumbar fractures treated conservatively between 1988 and 1999. The average follow-up was 77.5 (31-137) months and average patient age (23 women, 25 men) was 46 (18-76) years. Twenty-nine patients suffered a fall from a height and 13 patients were injured in traffic accidents. Thirty-two patients had compression-type fractures and 16 burst-type fractures. There were no neurological deficits. Twenty-nine patients were treated by orthosis, 13 by body cast and six by bed rest. In addition to pain and functional scoring, we measured a number of radiographic parameters at the time of admission and at latest follow-up and compared the values. In patients with compression fractures there were significant changes in scoliosis angle and wedging index (p<0.05). The mean pain score was 1.66 and mean functional score 1.03. In patients with burst fractures, vertebral index, wedging index and height loss increased after treatment (p<0.05). The mean pain score was 1.26 and functional score 0.93. Compression fractures with kyphosis angle <30 degrees are supposed to be stable and can be treated conservatively. If the kyphosis angle is more than 30 degrees, magnetic resonance imaging (MRI) should be performed, and if the posterior ligamentous complex is damaged, surgery should be considered. In burst fractures, MRI should always be performed and conservative treatment should only be considered if there is no neurological deficit and the ligaments are intact.
BACKGROUND: This study was conducted to evaluate the treatment of aseptic nonunion of the humeral shaft with a dynamic compression plate (DCP) and cancellous bone graft. METHODS: One hundred and five cases of nonunion of a humeral shaft fracture between 1982 and 2001 were analyzed retrospectively. The study population comprised 66 males and 39 females with an average age of 46.2 years (range, 17-81 years). Sixty-seven fractures were defined as atrophic nonunion, and 20 as hypertrophic nonunion, whereas 18 could not be defined clearly. All the fractures were managed by open reduction and internal fixation with DCP and cancellous bone graft. The mean follow-up period was 20 months (range, 14-28 months). RESULTS: All nonunion fractures united within an average of 16 weeks (range, 10-26 weeks). Complications included 4 patients with temporary radial-nerve palsies, and 3 patients with wound infections. At the final follow-up, shoulder and elbow functions of the operated limbs were all satisfactory. CONCLUSION: Fixation by DCP with supplemental cancellous bone graft is a reliable and effective treatment for nonunion of a humeral shaft fracture.
Fracture of the distal radius has a second peak of incidence in the second half of life. Because complex injuries are seen frequently, there is a need for differentiated treatment to achieve good results. The aim of our study was to evaluate the treatment of distal radius fractures with 2.4-mm locking compression (LC) plates in patients older than 65 years suffering from osteoporosis to determine the complications and compare costs of treatment with different interventions. Thirty-seven patients were included in this prospective study. The distribution of fractures according to AO classification was: nine type A, one type B, and 27 type C. The mean age was 76 years. Twenty-six volar plates, seven dorsal and four "sandwich" procedures were applied. The mean follow-up for 33 patients was 11.1 months. Using the functional Lidström score, we found 13 very good results, 15 good, four fair, and one poor, the radiologic Lidström scores were: 15 very good, 13 good, four fair, and one poor results. With the application of 2.4-mm LC plates, findings were good or very good in over 80%of osteoporotic distal radial fractures. Compared to other treatments, the real costs of intervention for LC plates is much higher.
Since the original description by Schneider (1956), the tear drop fracture is designated as a flexion fracture. The C.A.T. investigation proves the coexistence of two lines of fractures: a frontal fracture (by mechanism of flexion), a sagittal fracture (by compression). The sagittal fracture affects the body and the posterior arch in 48% of Lee's cases (1982) as Jefferson's fracture. The tear drop fracture is a fracture by mechanism of flexion-compression with sagittal sprain of the inter vertebral cervical disk. --In our experiences C5 is the level of the most frequent lesion. --4 types of tear drop fractures are described: an occult form (C.A.T. diagnosis), tear drop without displacement, tear drop with moderate displacement, tear drop with posterior dislocation and kyphosis greater than 20 degrees. --The spinal cord damage corresponds to displacement of the two half vertebral bodies and posterior dislocation. --In case with posterior dislocation and kyphosis greater than 20 degrees complete tetraplegia or anterior spinal cord injury are often presents. --In case with asymmetrical posterior displacement of an half vertebral body the syndrom of Brown Sequard is constant. --The tear drop fracture is unstable and cervical spine fusion necessary.
A study of the results of 26 cases of mandibular fracture treated by dynamic compression osteosynthesis by means of compression plates is presented. The advantages and disadvantages and complications of this technique are discussed.
Sixty patients with unilateral distal radius fractures were managed conservatively. Clinical assessment included objective and subjective evaluations of the outcome of treatment. Radiographic evaluation included fracture classification using the AO/ASIF system and measurement of volar tilt, radial inclination and radial height shortening at the end of treatment. Clinical signs of carpal tunnel syndrome were confirmed electrodiagnostically in 12 patients (20%) during the recovery period. Each patient had electrodiagnostic studies of both upper limbs performed to confirm the diagnosis. The mean time between injury and the onset of symptoms was 10 months (range 6.5 weeks-27 months). A statistically significant correlation between the final clinical results of treatment and post-traumatic median nerve compression neuropathy was found, but the occurrence of the neuropathy correlated with neither fracture type nor with the final radiographic findings. No clinical signs of ulnar or radial nerve compression occurred in this study.
The management of intra-articular fractures remains difficult. Shape memory compression staples fulfil nearly all the special treatment requirements of intra-articular fractures. Early bone union and 93.5 per cent satisfactory function were achieved in a series of 121 cases. Stable fixation, 'early' movement and continuous compressive force produced by the staple are the main factors contributing to good results.
Operative management of pelvic ring disruptions remains a challenge for the orthopedist. Surgical stabilization of an unstable pelvic ring not only involves urgent control of shock, but also protects soft tissues and enables the patient to ambulate earlier and to be comfortable when resting. Appropriate management of pelvic ring injuries requires understanding the anatomy and biomechanics of the pelvis and the mechanism of injury. The choice of posterior stabilization depends on the type of fracture. In this study we evaluated posterior tansiliac fixation using threaded compression rods (sacral bars), 1 of the techniques for treating pelvic instability with disruption of the posterior osseous - ligamentous complex. We used this method during 1987 - 1991 on 17 multitrauma patients with unstable pelvic injuries. We also conducted a long-term follow-up of more than 2 years. The 2 type C3 patients required revision of the posterior fixation, due to loss of stability and recurrence of dislocation of the sacroiliac joint. This seems to support the view that posterior sacral bar fixation is not suitable for bilateral rotational and vertical instability, and that it should be limited to certain posterior injury patterns, including lateral compression injuries and unilateral vertical instability when the contralateral hemipelvis is stable. It is important therefore, that the trauma surgeon be familiar with more than 1 technique of stabilization. Our study indicated that fixation with sacral bars is still an easy, safe and useful method for treating posterior pelvic instability, even though anatomical reduction of the sacroiliac joint is difficult. It should be one of the techniques with which the orthopedic trauma surgeon is acquainted and is ready to use when necessary.
Explore the source record for details and available documents.
Explore the source record for details and available documents.